GS-SR195V
1U Rack Mount Server
System Installation Guide
Intel® Pentium Xeon Processor Serverboard
Rev. 1.1
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Content
Chapter 5 BIOS Setup .......................................................................... 28
Main ........................................................................................................... 30
Advanced ................................................................................................... 33
PCI Configuration ............................................................................................................. 34
Advanced Chipset Control ............................................................................................. 36
Advanced Processor Option .......................................................................................... 39
Peripheral Configuration .................................................................................................. 41
Hardware Monitor ............................................................................................................ 45
Security ...................................................................................................... 46
Server ......................................................................................................... 48
Console Redirection ........................................................................................................ 48
Boot ............................................................................................................ 51
Exit ............................................................................................................. 52
Chapter 6 Appendix .............................................................................. 55
6-1: Acronyms ................................................................................................................. 55
3
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Safety, Care and Regulatory Information
ꢀ Important safety information
Read and follow all instructions marked on the product and in the documentation before you operate
your system. Retain all safety and operating instructions for future use.
* The product should be operated only from the type of power source indicated on the rating label.
* If your computer has a voltage selector switch, make sure that the switch is in the proper position for
your area. The voltage selector switch is set at the factory to the correct voltage.
* The plug-socket combination must be accessible at all times because it serves as the main disconnect-
ing device.
*All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power
outlet. This is a safety feature. The equipment grounding should be in accordance with local and national
electrical codes. The equipment operates safely when it is used in accordance with its marked electrical
ratingsandproductusageinstructions
* Do not use this product near water or a heat source.
* Set up the product on a stable work surface or so as to ensure stability of the system.
* Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you
provide adequate space around the system for ventilation when you set up your work area. Never insert
objects of any kind into the ventilation openings.
* To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets
before removing covers.
*Allow the product to cool before removing covers or touching internal components.
ꢀ Precaution for Product with Laser Devices
Observe the following precautions for laser devices:
* Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other than
thosespecifiedintheproduct'sdocumentation.
* Only authorized service technicians should repair laser devices.
ꢀ Precaution for Product with Modems, Telecommunications, ot Local Area
Network Options
Observe the following guidelines when working with options:
* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical
shock from lightning.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SafetyInformation
* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.
* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.
* Disconnect the modem cable before opening a product enclosure, touching or installing internal
components, or touching an uninsulated modem cable or jack.
* Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
ꢀ Federal Communications Commission (FCC) Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, andcanradiateradiofrequencyenergyand, ifnotinstalledandusedinaccordancewith
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission
limits. Neither the provider nor the manufacturer are responsible for any radio or television interference
caused by using other than recommended cables and connectors or by unauthorized changes or
modifications to this equipment. Unauthorized changes or modifications could void the user's authority to
operatetheequipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
ꢀ FCC part 68 (applicable to products fitted with USA modems)
The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among
otherinformation,theFCCregistrationnumberandRingerEquivalenceNumber(REN)forthisequipment.
You must, upon request, provide this information to your telephone company.
If your telephone equipment causes harm to the telephone network, the Telephone Company may
discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not
practical, you will be notified as soon as possible.You will be informed of your right to file a complaint with
the FCC.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Your telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect proper operation of your equipment. If they do, you will be notified in advance to give you an
opportunitytomaintainuninterruptedtelephoneservice.
The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part
68, Sec. 68.381 (c) (3)).
/ for Canadian users only /
ꢀ Canadian Department of Communications Compliance Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital
apparatus as set out in the radio interference regulations of Industry Canada.
Lepresentappareilnumeriquen'emetpasdebruitsradioelectriquesdepassantleslimitesapplicablesaux
appareilsnumeriquesdeClasseBprescritesdanslereglementsurlebrouillageradioelectriqueedictepar
IndustrieCanada.
ꢀ DOC notice (for products fitted with an Industry Canada-compliant modem)
The Canadian Department of Communications label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective, operational and safety
requirements. TheDepartmentdoes notguaranteetheequipmentwilloperatetotheusersatisfaction.
Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the
localTelecommunications Company.The equipment must also be installed using an acceptable method
ofconnection.Thecustomershouldbeawarethatcompliancewiththeaboveconditionsmightnotprevent
degradation of service in some situations.
RepairstocertifiedequipmentshouldbemadebyanauthorizedCanadianmaintenancefacilitydesignated
by the supplier.Any repairs or alterations made by the user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if resent are connected together. This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SafetyInformation
NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that the
sum of the Load Numbers of all the devices does not exceed 100.
/ for European users only /
CAUTION
Danger of explosion if battery is incorrectly
replaced.
Replace only with the same or equivalent
type recommended by the manufacturer.
Dispose of used batteries according to the
manufacturer’sinstructions.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Introduction
Welcome to Gigabyte GS-SR195V Rack mount Server System Installation Guide. The guide
provides instructions for configuration hardware for the GS-SR195V your system.
This installation guide will assist you in installing all the essential components for the sever system.
For your protection, please read and undertand all of the safety and operating instructions regarding your
Gigabyte Server and retain for future reference. The procedures in this guidebook assusme that your are
a system or network administrator experienced in installing similar hardware.
Contents Packages
Whenopeningthepackage,pleaseensure thesystemcomponentsarenotdamagedduringtheshipping.
Using the following checklist to verify the contents. If any component is missing or damaged in the
system, please contact your vendor immediately.
; Chassis
;
;
;
;
;
;
GA-9IVDPC Motherboard (Installed)
GC-REIU (PCI-E Riser Card)
CPU Heat Sink x 2
; Power Supply (Installed)
; FAN Duct x 1
; Silm type CD-ROM drive (Installed)
; GS-SR195V System Installation Guide
; Driver CD for motherboard driver & utility
Cables (RJ45)
Case Handle Kit x 2
COM2 Cable x 1
WARNING!
Computer motherboards and expansion cards contain very delicate Integrated Circuit (IC) chips. To
protect them against damage from static electricity, you should follow some precautions whenever you
work on your computer.
1. Unplug your computer when working on the inside.
2. Use a grounded wrist strap before handling computer components. If you do not have
one, touch both of your hands to a safely grounded object or to a metal object, such as
the power supply case.
3. Hold components by the edges and try not touch the IC chips, leads or connectors, or
othercomponents.
4. Place components on a grounded antistatic pad or on the bag that came with the
components whenever the components are separated from the system.
5. Ensure that theATX power supply is switched off before you plug in or remove theATX
powerconnectoronthemotherboard.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Feature Summary
Chapter 1 Features Summary
Motherboard
ꢁ
GA-9IVDPC
Processor Supported ꢁ Dual socket 604 for Intel® Xeon(Nocona/Irwindale) processor
suopprts 3.6 GB and upper
ꢁ
ꢁ
ꢁ
ꢁ
Intel® Xeon (Nocona/Irwindale) CPUs supports 800 MHz FSB
2nd cache depend on CPU
Intel® E7320 Chipset
Intel® 6300ESB
Chipset
System Memory:
Memory Capacity
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Supports maximum 32GB with DDR 266
Supports maximum 16GB with DDR333
8 x Registered DDR 266 scoket
6 x Registered DDR 333 scoket
Single-bit Errors Correction, Multiple Bit Errors Detection
DIMM Sparing support, support for RASUM fail-over to an on-line
spare DIMM device
Memory Type
Error Correction:
AdditionalFeatures
Expansion Slot
RAID Supported
Cooling Fans:
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
1 riser card supports 1 x PCI-X 64/66MHz add-on card
1 x PCI-E x8 slot
Adaptec® 7901X
Supports Host RAID 0,1,10
4 X CPU Fans
1 X Power Fan
Integrated LANs:
Controller
ꢁ
ꢁ
ꢁ
ꢁ
Broadcom® BCM5721 and BCM 5705 GbE
WOL, Teaming, ALB, AFT
Features
BCM5721 supports PCI-Express
BCM5705 suports PCI 32/33MHz
Integrated Graphics:
Controller
ꢁ
IntegratedATIRageXL
Mass Storage System ꢁ 4 x Hot Swapable SCSIHDDs
1 Slim Type 24X CD-ROM
ꢁ
9
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
SCSI Controller:
Controller
ꢁ
AdaptecAIC- 7901X chipset
RAID Supported
Features
ꢁ
ꢁ
ꢁ
Supports Host RAID RAID 0, 1 and 10 data protection
Mirroringsupportsautomaticbackgroundrebuilds
Features LBA and Extended Interrupt 13 drive translation in
controller onboard BIOS
ZCRSupported(Optional) ꢁ One SO-DIMM I/F on board support for ZCR card extension
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
OptionalAdaptecASR2015S& ASR2025S ZCR
Supports Hardware RAID 0,1,5,10,50, JBOO
Power SW, Reset SW, NMI SW, UID SW,
2 x LAN LED
Front Panel
1 x Power/Sleep LED
1 x HDD LED
1 x System Status LED
2 x USB
Super I/O
Controller
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
ITE IT8712F-IX
AdditionalFeatures
Hardware Monitor
Supports Wake on Ring
CPU/System Fan Revolution detect
CPU/System temperature detect
System Voltage Detect
Built-in I/O
2 x Serial ports (COM, 1 at rear and 1 at front)
1 x USB 2.0 dual-port connector
1 x VGA connector
2 x RJ45 LAN ports
P/S 2 Keyboard and Mouse Connectors
System BIOS:
BIOS Type
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Lincensed Phoenix on 8Mb Flash RAM
Supportsmultibootfunction
SpecialFeatures
User setting for hardware monitoring
Supports PXE
ACPI 1.0 Compliant/ ACPI defined S1, S4, and S5
10
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Server Management Functions:
BMC Chip
ꢁ
ꢁ
ꢁ
ꢁ
NS IPMI 1.5 controller
FailureDetection
Event Logging
IPMI 1.5 specification of Server management
32KB Nonvolatile Memory to Log System Failure Events
Follow the IPMI 1.5 specification of Server management
RemoteManagement
Environment
AmbientTemperature
ꢁ
ꢁ
ꢁ
ꢁ
ꢁ
Operating Temperature: 5oC to 35oC
Non-operatingTemperature: 0oC to 50oC
10-80% operating Humidity at 30o C
FCC, CE, BSMI, CB,
Relative Humidity
Safety Regulations
System Dimention:
19"W x 1.73"H x 19.5"D
Electrical Power Supply ꢁ Single Power Supply 480W
Note:
1. If you want to purchase USB FDD, we suggest MITSUMI as
recommended brand.
2. The extended lan port is difficult to unplug, please handle it carefully.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Chapter 2 System Hardware Installation
Please observe the safety information in chapter “Important Safety Information”
Do not expose the server to extreme environmental conditions. Protect it from dust,
humidity, and heat.
Step 2-1: Chassis Removal and Installation
Step 1 Loosen thscrew from the top cover.
Step 2 Push down the indentation located at two sides of the chassis, and slide toward to remove the
top cover.
Step 3 Reverse Step 1, and 2 to replace the chassis cover.
Step 2
Step 1
Screw
Note: Before installing CPU, you must remove the FAN duct. For FAN duct removal, please
see Sub-section 2-7 “FAN Duct Removal and Installtion” for detail instruction.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation Process
Step 2-2: CPU Installation
Please make sure the CPU type and speed that are supported by the motherboard.
Step 1 Raise the locking bar on the socket.
Step 2 Aligning the pins of the processor with the socket, insert the processor into the socket.
Step 3 Close the handle completely and finish CPU installation.
Step 1
Step 2
Pin1 indicator
Step 3
13
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Step 2-3: Heat Sink Installation
Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well
remember to apply the thermal conductivity compound on the CPU.
Step 2 Seat the heat sink with the four screws. Installation completed.
Step 1
Step 2-4: Memory Installation
1. The DIMM slot has a notch, so the DIMM memory module can only fit in one direction.
2. Insert the DIMM memory module vertically into the DIMM slot. Then push it down.
3. Close the plastic clip at both edges of theDIMM slots to lock the DIMM module.
4. DIMM must be populated in order starting at the farthest slot from the MCH chipset.
Each logical DIMM must be made of two identical DIMMs having the same device size on
each and the same DIMM size.
5. Reverse the installation steps when you wish to remove the DIMM module.
For detail DIMM Population, please refer to section 4-2: DDR DIMM Slot Population
Step 2
Step 1
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation Process
Step 2-5: PCI Expansion Card Installation
GS-SR195V provides expansion riser slot for one PCI-X 64/66MHz slot; and one with PCI-E
x8 and x4 slots. To install the peripheral, please go through the following steps.
Note:
Before installing the PCI expansion card, please check the card size limitation. Size limitation for
PCI-E is listed below:
Heigth: 18.73mm(max) ; Length: 167.65mm(max) ; Width: 52mm(max)
Step 1 Lift the riser bracket slightly, then pull it out from the server chassis.
Step 2 Align the expansion card with the guiding groove. Slide the expansion card into the slot until
the card firmly seats.
Step 3 Align the riser bracket to the system module (see the arrow direction mark 1), and push
it to locked position.
Note!! The riser bracket must be firmtly seated into the module. (See the arrowdirection),
or it will cause power connection losses.
Step 4 Reverse Step 1 & 2 to lock the riser bracket firmly. Installation completed.
Step 1
Step 2
Step 3
15
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Step 2-6: Hard Disk Drive Installation
Step 1 Press the release button and pull the blank out of the drive bay.
Step 2 Remove the hard disk blank. Slide hard disk into blank and secure it with screws.
Step 3 Slide the drive into the cage until it clicks, locking the drive into place. Connect cable and
power.
Step 2
Step 1
Release button
Step 2-7: FAN Duct Removal and Installation
Step 1 Pull up the screw-holder and lossen the thumbscrews. Lift up to remove the fan duct.
Step 2 For FAN Duct Installation, place the fan duct on the top of heat sinks. Fasten the screws to the
locked position and push down the screw-holders.
Step 1
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation Process
Step 2-8: ZCR Installation and Removal (Optional Device)
Step 1 Aling a ZCR on the module such that the notch on the ZCR exactly match the notches in
themodule.
Step 2 Push the card in untill it clicks. Then, press down the card vertically.
Step 3 To remove the ZCR card, unlock the ZCR retaining clips.
Step 1
Step 2
Step 3
17
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Chapter 3 Appearance of GS-SR195V
3-1: Front View of GS-SR195V
ꢃ
ꢄ
ꢂ
ꢅ
ꢂ
ꢃ
ꢄ
ꢅ
Slim Type CD-ROM
USB Connector
LEDs
Hot swap SCSI HDDs
18
Download from Www.Somanuals.com. All Manuals Search And Download.
SystemAppearance
3-2: Rear View of GS-SR195V
ꢉ
ꢊ
ꢈ
ꢂ
ꢆ
ꢅ ꢇ
ꢄ
ꢃ
ꢂ
PS/2 Connectors
USB Connectors
LAN1 Port (RJ45)
LAN2 Port (RJ45)
COM Port
ꢃ
ꢄ
ꢅ
ꢆ
ꢇ
ꢈ
ꢉ
ꢊ
VGA Port
Limited Low-Profile Riser Slot
Full-Height Riser Slot
Power cord
19
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
3-3: Switch and LED Indicators Introduction
LAN1/2 Activities
System Event LED
Reset
ID BTN&LED
Power
HDD
NMI
Name
Color
Green
Green
--
Condition
On
Description
Power
Power On
Blink
Off
Sleep (S1)
Power Off (S4)
SYS
Amber
Blink
System Ready but degraded, CPU Failed,
DIMM Killed
(System)
Amber
On
Critical Alarm: Critical Power Module Failure,
Critical FANs Failure, Voltage (Power Supply)
CriticalTeemperatureandVoltage
System healthy.
--
Off
HDD
Green
Amber
Amber
--
Blink
On
Hard Disk Drive Access
HDD Fault
Blink
Off
HDD Rebuild
No Access and No HDD Fault
LAN Link / No access
LAN access
LAN1
Green
Green
--
On
Activity
Blink
Off
Idle
LAN2
Green
Green
--
On
LAN Link / No access
LAN access
Activity
Blink
Off
Idle
ID
Blue
On
Untiselectedforidentification
Noidentification
(Identification) --
Off
20
Download from Www.Somanuals.com. All Manuals Search And Download.
LED Description
3-4: LAN LED Description
Name
Color
Condition
ON
Description
LAN
Green
LAN Link / no Access
LAN Access
Link/ActivityGreen
BLINK
OFF
-
Idle
GbE LAN Yellow
ON
1Gbpsconnection
100Mbpsconnection
10Mbpsconnection
Speed
Green
-
ON
OFF
21
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
3-5 : Connector Icon Description
Suggest Icon
Description
Keyboard
VGA
Mouse
LAN
Serial Port
USB
22
Download from Www.Somanuals.com. All Manuals Search And Download.
MotherboardLayout
Chapter 4 Motherboard Layout & Jumper Setting
4-1: GA-9IVDPC Motherboard Layout
I
H
EC4
X
F
B
A1T
K
J
L
G
C
V
M
U
N
O
W
S
D
P
Q
R
E
1
A
B
T
1
7
1
7
1
7
1
23
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
A
B
C
D
E
F
CPU 0
M
N
O
P
DDRA2
CPU1
DDR B2
Intel MCH E7320
ATIRage-XL
Intel 6300ESB
Broadcom® BCM5705
Broadcom® BCM 5721
IT8712F-IX
COM2
DDR A3
DDR B3
Q
R
S
DDR A4
DDR B4
G
H
I
IPMI Connector
AdaptecAIC-7901X
PCI-X_1 (64/66MHz)
PCI-E ( x4 Lane x8 Slot )
SO-DIMM Type ZCR Extention Slot **
Battery
T
U
V
W
X
J
GPIO
K
L
DDRA1
DDR B1
**This device is use for Adaptec ASR-2015s and ASR-2025s ZCR population.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
MotherboardLayout
4-2: DDR DIMM Slot Population
Table 4-2-1: Supported DDR266 DIMM Populations
NOTE!! For DDR-266 DIMM population, DIMM must be populated starting from
the A4/B4 slots.
DIMM Configuration
1 Single Rank
DIMM1
Empty
Empty
Empty
DIMM2
Empty
Empty
Empty
Empty
Empty
DIMM3
Empty
Empty
DIMM4
Single Rank
Dual Rank
1 Dual Rank
2 Single Rank
Single Rank Single Rank
1 Dual Rank, 1 Single Rank Empty
Dual Rank
Dual Rank
Single Rank
Dual Rank
2 Dual Rank
Empty
Empty
3 Single Rank
Single Rank Single Rank Single Rank
1 Dual Rank, 2 Single Rank Empty
2 Dual Rank, 1 Single Rank Empty
Dual Rank
Dual Rank
Dual Rank
Single Rank Single Rank
Dual Rank
Dual Rank
Single Rank
Dual Rank
3 Dual Rank
Empty
4 Single Rank
Single Rank
Single Rank Single Rank Single Rank
Single Rank Single Rank Single Rank
1Dual Rank, 3 Single Rank Dual Rank
2 Single Rank, 2 Dual Rank Dual Rank
3 Dual Rank, 1 Single Rank Dual Rank
Dual Rank
Dual Rank
Dual Rank
Single Rank Single Rank
Dual Rank
Dual Rank
Single Rank
Dual Rank
4 Dual Rank
Dual Rank
Table 4-2-2: Supported DDR333 DIMM Populations
NOTE!! For DDR-333 DIMM population, DIMM must be populated starting from
the A3/B3 slots. A4/B4 slots cannot be applied for DDR-333 DIMM. The
mainboard only supports 6 DIMMs for DDR-333.
DIMM Configuration
1 Single Rank
DIMM1
Empty
Empty
Empty
DIMM2
Empty
Empty
DIMM3
Single Rank
Dual Rank
1 Dual Rank
2 Single Rank
Single Rank Single Rank
1 Dual Rank, 1 Single Rank Empty
Dual Rank
Dual Rank
Single Rank
Dual Rank
2 Dual Rank
Empty
3 Single Rank
Single Rank
Single Rank Single Rank
Single Rank Single Rank
1 Dual Rank, 2 Single Rank Dual Rank
25
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
4-3: Jumper Setting
CLR_CMOS ( (Clear CMOS Function)
You may clear the CMOS data to its default values by this jumper.
Default value doesn’t include the “Shunter” to prevent from improper use this jumper.
To clear CMOS, temporarily short 1-2 pin.
EC4
B
A1T
1 1-2 close: Clear CMOS
1
2-3 close: Normal (Default value)
1
1
7
1
7
1
7
1
BIOS_TBL (CMOS Lock Function)
EC4
B
A1T
1-2 close: Top block lock
1
1
2-3 close: Disable Top block
function (Default value)
1
1
7
1
7
1
7
1
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Jumper Setting
BIOS_WP (BIOS Werite Protect Function)
EC4
B
A1T
1-2 close: Enable BIOS Write Protect
1
Function
2-3 close: BIOS writable. (Default value)
1
1
1
7
1
7
1
7
1
27
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Chapter 5 BIOS Setup
BIOS Setup is an overview of the BIOS Setup Program. The program that allows users to modify the
basic system configuration. This type of information is stored in battery-backed CMOS RAM so that it
retains the Setup information when the power is turned off.
ENTERINGSETUP
Power ON the computer and press <F2> immediately will allow you to enter Setup.
CONTROLKEYS
<Ç>
<È>
<Å>
<Æ>
<Esc>
Move to previous item
Move to next item
Move to the item in the left hand
Move to the item in the right hand
Main Menu - Quit and not save changes into CMOS Status Page Setup Menu and
Option Page Setup Menu - Exit current page and return to Main Menu
<+/PgUp> Increase the numeric value or make changes
<-/PgDn> Decrease the numeric value or make changes
<F1>
<F2>
<F3>
<F4>
<F6>
<F7>
<F8>
<F9>
<F10>
General help, only for Status Page Setup Menu and Option Page Setup Menu
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
LoadtheOptimizedDefaults
Save all the CMOS changes, only for Main Menu
28
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
GETTINGHELP
MainMenu
The on-line description of the highlighted setup function is displayed at the bottom of the screen.
Status Page Setup Menu / Option Page Setup Menu
Press F1 to pop up a small help window that describes the appropriate keys to use and the
possible selections for the highlighted item. To exit the Help Window press <Esc>.
z
z
Main
This setup page includes all the items in standard compatible BIOS.
Advanced
This setup page includes all the items ofAMI special enhanced features.
(ex:Auto detect fan and temperature status, automatically configure hard disk parameters.)
z
z
z
z
Security
Change, set, or disable password. It allows you to limit access the system and setup.
Server
Serveradditionalfeatures enabled/disabledsetupmenus.
Boot
This setup page include all the items of first boot function features.
Exit
There are five optionsin this selection: Exit Saving Changes, Exit Discarding Changes, Load
Optimal Defaults, Load Failsafe Defaults, and Discard Changes.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Main
Once you enter Phoenix BIOS Setup Utility, the Main Menu (Figure 1) will appear on the screen. Use
arrow keys to select among the items and press <Enter> to accept or enter the sub-menu.
PhoenixBIOS Setup Utility
Main
Advanced
Security
[00:13:12]
Server
Boot
Exit
System Time:
System Date:
Item Specific Help
[01/01/2005]
ꢀIDE Channel 0 Master
ꢀIDE Channel 0 Slave
ꢀIDE Channel 2 Master
ꢀIDE Channel 3 Slave
ꢀSystem Information
[CD-ROM]
[None]
[None]
[None]
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 1: Main
ꢋSystem Time
The time is calculated based on the 24-hour military time clock. Set the System Time (HH:MM:SS)
ꢋSystemDate
Set the System Date. Note that the “Day” automatically changed after you set the date.
(Weekend: DD: MM: YY) (YY: 1099~2099)
30
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
ꢋIDE Channel 0 Master, Slave / Channel 1 Master, Slave, Serial ATA
ThecategoryidentifiesthetypesofharddiskfromdriveCtoFthathasbeeninstalledinthecomputer.
There are two types: auto type, and manual type. Manual type is user-definable;Auto type which will
automatically detect HDD type.
Note that the specifications of your drive must match with the drive table. The hard disk will not work
properly if you enter improper information for this category.
If you select User Type, related information will be asked to enter to the following items. Enter the
information directly from the keyboard and press <Enter>. Such information should be provided in the
documentation form your hard disk vendor or the system manufacturer.
ꢁ TYPE
1-39: Predefined types.
Users: Set parameters by User.
Auto: Set parameters automatically. (Default Vaules)
CD-ROM: Use for ATAPI CD-ROM drives or double click [Auto] to set all HDD parameters
automatically.
ATAPI Removable: Removable disk drive is installed here.
ꢁ Multi-Sector Transfer
This field displays the information of Multi-Sector Transfer Mode.
Disabled: The data transfer from and to the device occurs one sector at a time.
Auto: The data transfer from and to the device occurs multiple sectors at a time if the device
supportsit.
ꢁ
LBA Mode
This field shows if the device type in the specific IDE channel
support LBA Mode.
ꢁ 32-Bit I/O
Enable this function to max imize the IDE data transfer rate.
This field shows the information ofTeansfer Mode.
ꢁ Transfer Mode
ꢁ
Ultra DMA Mode
This filed displays the DMA mode of the device in the specific IDE
channel.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
ꢋSystemInformation
This category includes the information of Processor Type, Speed, Extended memory, BIOS Version,
BIOS Date, System Product Name, System serial number, System version, System UUID, Main Board
ID, and Main Board Serial number.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
Advanced
About This Section: Advanced
With this section, allowing user to configure your system for basic operation. User can change the
processor options, chipset configuration, PCI configuration and chipset control.
PhoenixBIOS Setup Utility
Main
Advanced
Security
Server
Boot
Exit
ꢀPCI Configuration
Item Specific Help
ꢀAdvanced Chipset Control
ꢀAdvanced Processor Option
ꢀPeripheral Configuration
ꢀHardware Monitor
Reset Configuration Data
ClkGen Spread Spectrum
System After AC Back
Extended Memory Testing
Network Server
[No]
[Disabled]
[Pre-State]
[Enabled]
[Enabled]
[Enter]
Clear Case Open Log
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 2: Advanced
33
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
PCI Configuration
PhoenixBIOS Setup Utility
PCI Configuration
ꢀEmbedded Vedio Controller
ꢀEmbedded SCSI Controller
ꢀEmbedded NIC
Item Specific Help
ꢀEmbedded NIC (Gbit#2)
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 2-1: PCI Configuration
ꢋEmbeddedVideoController
ꢀ Onboard VGA Control
ꢁEnabled
ꢁDisabled
Enable onboard VGA device. (Default value)
Disablethisfunction.
ꢋEmbeddedSCSIController
ꢀ Option ROM Scan
ꢁEnabled
Enableing this item to initialize device expansion ROM.
(Defualtvalue)
ꢁDisabled
Disablethisfunction.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
ꢋEmbeddedNIC (Gbit #1 / 2)
ꢀ Onboard LAN Control
ꢁEnabled
ꢁDisabled
Enable onboard LAN 1 / 2 device. (Default value)
Disablethisfunction.
ꢀ Option ROM Scan
ꢁEnabled
Enableing this item to initialize device expansion ROM.
Disable this function. (Defualt value)
ꢁDisabled
35
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Advanced Chipset Control
PhoenixBIOS Setup Utility
Advanced Chipset Control
USB Controller
Item Specific Help
[Enabled]
[Disabled]
[Enabled]
[Enabled]
[Enabled]
[128MB]
[Enabled]
[Auto]
Legacy USB Support
Force Compliance Mode
PCI-E port A Device 2
PCI-E port A1 Device 3
4GB PCI Hole Granularity
Data Parity Error Recovery
Memory Frequency
Wake On LAN
[Enabled]
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 2-2: Advanced Chipset Control
ꢋUSB Controller
This item allows users to enable or disable the USB device by setting item to the desired value.
ꢁEnabled
ꢁOptions
Enable USB controller. (Default value)
Disbalethisfunction.
ꢋLegacy USB Support
This option allows user to function support for legacy USB.
ꢁEnabled
ꢁDisabled
Enables support for legacy USB. (Default Value)
Disables support for legacy USB.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
ꢋForceComplianceMode
This option allows user to function PCI-E Compliance mode by setting item to desired value.
ꢁEnabled
ꢁDisabled
Enables PCI-E Force Compliance mode. (Default Value)
Disables this function.
ꢋPCI-E portA Device 2
Force PCI Express v1.0 Compability Mode, this PCI-E port A by setting to desired value.
ꢁForce PCI Express 1.0
ꢁEnabled
Force PCI Express v1.0 Compability Mode.
Enables PCI-E port A Device2 (Default Value)
Disables this function.
ꢁDisabled
ꢋPCI-E portA1 Device 3
Force PCI Express v1.0 Compability Mode, this PCI-E port A1 by setting to desired value.
ꢁForce PCI Express 1.0
ꢁEnabled
Force PCI Express v1.0 Compability Mode.
Enables PCI-E port A1 Device3 (Default Value)
Disables this function.
ꢁDisabled
ꢋ4GB PCI HoleGranularity
Select the granularity of PCI hole for PCI resource. If MTRRS are not enough, we may use this
option to reduce the MTRR occupation.
ꢁ128MB
ꢁ256MB
Select 128MB as granularity of PCI hole. (Default value)
Select 256MB as granularity of PCI hole.
ꢋData Parity Error Recovery
ꢁEnabled
Enabledataparityerrorrecoveryfunction.(Defaultvaules)
Disablethisfunction.
ꢁDisabled
37
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
ꢋMemoryFrequency
Determine the specifiy memory frequency.
ꢁ266MHz
ꢁ333MHz
ꢁAuto
Select 266MHz as memory frequecncy for system.
Select 333MHz as memory frequecncy for system.
Auto determine memory frequency for system.
(Defaultvalues)
ꢋWake On LAN
This option allow user to determine the action of the system when a LAN wake up occurs.
ꢁEnabled
ꢁDisabled
Enable Wake On LAN. (Default value)
Disablethisfunction.
Note: This item must enabled if you’re running under Windows operating system.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
Advanced Processor Option
PhoenixBIOS Setup Utility
Advanced Processor Option
Hyper Threading Technology
Machine Cecking
Item Specific Help
[Enabled]
[Disabled]
[Disabled]
[Enabled]
Thermal Management 2
Adjacent Cache Line Prefetch
Set Max Ext CPUID = 3
Thermal Management 1
NX Protection
[Disabled]
[Disabled]
[Enabled]
F1: Help
Esc: Exit
KL: Select Item
+ -: Change Values
F5: Setup Defaults
IJ: Select Menu
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 2-3: Advanced Processor Option
ꢋHyperThreading Technology
ꢁEnabled
Enables Hyper-Threading Technology Feature when using Windows
XP operating systems that are optimized for Hyper-Threading
technology. (Default value)
ꢁDisabled
Disables Hyper-ThreadingTechnology when using other operating
systems.
ꢋMachine Checking
ꢁEnabled
ꢁDisabled
EnableMachine Checking. (Default value)
Disablethisfunction.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
ꢋThermal Managerment 2
Select between TM1 and TM2.
ꢁEnabled
ꢁDisabled
Select Thermal Management 2 function.
Disable this function. (Default value)
ꢋAdjacent Cache Line Prefetch
ꢁEnabled
Processor will fetch both cache lines when it requires data that is not
currently inits cache. (Defualt value)
ꢁDisabled
Processor will only fetch the cache line that contains the data currently
required by the processor.
ꢋSet Max Ext CPUID = 3
Set MAX CPUID extended function value to 3.
ꢁEnabled
ꢁDisabled
Enable Set Max Ext CPUID = 3 function.
Disable this function. (Default value)
ꢋThermal Managerment 1
If enabled, when the thermal sensor indicates that the die temperature is at the pre-determined
threshold, the processor will reduce the bus to core ratio and operating voltage.
ꢁEnabled
ꢁDisabled
Enable Thermal Management 1 function. (Default value)
Disablethisfunction.
ꢋNX Protection
This category provides user to enable virus protection avoiding unknow and spite attack.
ꢁEnabled
ꢁDisabled
NX Protection function. (Default value)
Disablethisfunction.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
Peripheral Configuration
PhoenixBIOS Setup Utility
Peripheral Configuration
Serial Port A
Base I/O address/IRQ
Serial Port B
Item Specific Help
[Enabled]
[3F8/IRQ4]
[Enabled]
[2F8/IRQ3]
[Enabled]
[Enabled]
[Both]
Base I/O address/IRQ
Floppy disk controller
Floppy Check
Parallel ATA
Serial ATA
[Enabled]
[Auto]
Native Mode Operation
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 2-4: Peripheral Configuration
ꢋSerial Port A
This allows users to configure serial protA by using this option.
ꢁDisabled
ꢁEnabled
Disabletheconfiguration.
Enable the configuration (Default value)
ꢀ
Base I/O Address/IRQ
ꢁ3F8/IRQ4
Set IO address to 3F8. (Default value)
Set IO address to 2F8.
ꢁ2F8/IRQ3
ꢁ3E8/IRQ4
ꢁ2E8/IRQ3
Set IO address to 3E8.
Set IO address to 2E8.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
ꢋSerial Port B
This allows users to configure serial prot B by using this option.
ꢁDisabled
ꢁEnabled
Disabletheconfiguration.
Enable the configuration (Default value)
ꢀ
Base I/O Address/IRQ
ꢁ3F8/IRQ4
Set IO address to 3F8.
ꢁ2F8/IRQ3
ꢁ3E8/IRQ4
ꢁ2E8/IRQ3
Set IO address to 2F8. (Default value)
Set IO address to 3E8.
Set IO address to 2E8.
ꢋFloppy disk controller
ꢁEnabled
Enable the floppy disk controller. (Default value)
Disable the device.
ꢁDisabled
ꢋFloppy Check
ꢁEnabled
Enable the device to verify floppy typer when system boot.
Disable the this function. (Default value)
ꢁDisabled
ꢋParallelATA
ꢁDisabled
Disable the device.
ꢁBoth
Select both Channel 0 and Channel 1 as ParallelATA.
(Defaultvalue)
ꢁChannel 0
ꢁChannel1
Select both Channel 0 as ParallelATA.
Select both Channel 1 as ParallelATA.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
ꢋSerial ATA
ꢁEnabled
Enable Serial ATAdevice. (Default value)
Disable the SerialATA.
ꢁDisabled
ꢋNativeModeOperation
This option allows user to set the native mode for ATAfunction.
Note that certain OS is not supported under Native Mode.
ꢁAuto
Autodetected. (Defaultvalue)
Set Native mode to Serial ATA.
ꢁSerialATA
ꢁParallelATA Set Native mode to ParallelATA.
ꢋReset ConfigurationData
ꢁYes
ꢁNo
Clear the Extended System Configuration Data (ESCD) area.
Disable this function. (default value)
ꢋClkGen Spread Spectrum
ꢁEnabled
ꢁDisabled
Enable ClkGen Spread Spectrum.
Disabled this function. (Default value)
ꢋSystem AfterAC Back
Set the mode od operation if anAC/Power loss occurs.
ꢁPower On
ꢁStay Off
Power on system without pressing power button.
Keep the power off until the power button is pressed.
ꢁPre- State
Set system to the last sate when AC power is removed. Do not power on
system when AC power is back. (Default value)
43
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
ꢋExtendedMemoryTesting
Determine which type of tests will be performed extended memory. (above 1M)
ꢁEnabled
ꢁDisabled
Enable Extended Memory Testing. (Default value)
Disablethisfunction.
ꢋNetwork Server
ꢁEnabled
System will be secured at boot to prevent tampering during network
operation.(Defaultvalue)
ꢁDisabled
Disablethisfunction.
ꢋClear Case Open Log
Press [Enter] to clear the Case Open Log.
When you press <Enter> on this item, you will get a confirmation dialog box with a message
as below:
Setup Confirmation
Are you sure to clear the Case Open Log?
[Yes]
[No]
44
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
Hardware Monitor
PhoenixBIOS Setup Utility
Hardware Monitor
CPU 1 Temperature
CPU 2 Temperature
System Temperature
Item Specific Help
38C/100F
38C/100F
38C/100F
33C/091F
33C/091F
33C/091F
W83792d Temperature
W83792d Temperature 2
W83792d Temperature 3
ꢀVoltage Monitor
ꢀFan Monitor
1
F1: Help
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Esc: Exit
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 2-5: Hardware Monitor
ꢋCPU 1&2/ System/ W83792d 1/2/3 Temperature
ꢁDisplay the current CPU1/2 temperature, System, and W83792d 1/2/3 ambient temperature.
ꢋVoltage: VCORE 1&2/ 3.3V/ +12V / 1.5V / 2.5V
ꢁDetect system's voltage status automatically.
ꢋFAN(RPM)
ꢁDisplay the current CPUs, and Power FAN speed.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Security
PhoenixBIOS Setup Utility
Security Server Boot
Clear
Main
Advanced
Exit
Item Specific Help
Supervisor Password Is:
User Password Is:
Clear
Set Supervisor Password
Set User Password
Password On Boot
[Enter]
[Enter]
[Disabled]
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 3: Security
*
About This Section: Security
In this section, user can set either supervisor or user passwords, or both for different level of
password securities. In addition, user also can set the virus protection for boot sector.
ꢋSet Supervisor Password
You can install and change this options for the setup menus. Type the password up to 6
characters in lengh and press <Enter>. The password typed now will clear any previously
entered password from the CMOS memory. You will be asked to confirm the entered
password. Type the password again and press <Enter>. You may also press <Esc> to abort
the selection and not enter a specified password or press <Enter> key to disable this option.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
ꢋSet User Password
You can only enter but do not have the right to change the options of the setup menus. When
you select this function, the following message will appear at the center of the screen to assist
you in creating a password.
Type the password up to 6 characters in lengh and press <Enter>. The password typed now
will clear any previously entered password from the CMOS memory. You will be asked to
confirm the entered password. Type the password again and press <Enter>. You may also
press <Esc> to abort the selection and not enter a specified password.
ꢋPassword on boot
Password entering will be required when system on boot.
ꢁEnabled
ꢁDisabled
Requries entering password when system on boot.
Disable this function. (Default value)
47
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Server
PhoenixBIOS Setup Utility
Security Server Boot
Main
Advanced
Exit
ꢀConsole Redirection
Halt On
Item Specific Help
[Mid]
Clear Mem. ECC Error Info.
Fatal A on port A
[Disabled]
[Enabled]
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 4: Server
Console Redirection
PhoenixBIOS Setup Utility
Console Redirection
Com Port Address
Baud Rate
Item Specific Help
[19.2K]
[Direct]
[CTS/RTS]
[Off]
Console Type
Flow Control
Continue C.R after POST
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 4-1: Console Redirection
48
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
ꢋCom PortAddress
If this option is set to enabled, it will use a port on the motherboard.
ꢁOn-board COMA
ꢁOn-board COMB
ꢁDisabled
Use COMA as he COM port address.
Use COMB as he COM port address.
Disable this function. (Default value)
ꢋBaudRate
This option allows user to set the specified baud rate.
ꢁOptions
300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, 115.2K.
ꢋConsoleType
This option allows user to select the specified console type. This is defined by IEEE. PC-ANSI
is the standard PC-type terminal. Note that for VT100+, you must select English as your
languuage. And VT-UTF8 uses unicode.
ꢁOptions
vt100, vt100+, vt100 8bit, PC ANSI 7bit, PC-ANSI, VT-UTF8.
ꢋFlowControl
Enables Flow Control when EMP is dahring the same serial port as console redirection, the flow
control must be set to CTS/RTS or CTS/RTS+CD depending on whether a modem is used.
ꢁNone
Notsupported.
ꢁXON/OFF
ꢁCTS/RTS
Softwarecontrol.
Hardware control. (Default values)
ꢋContinue C.R. after POST
This option allows user to enable console redirection after O.S has loaded.
ꢁOn
ꢁOff
Enable console redirection after O.S has loaded.
Disable this function. (Default value)
49
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
ꢋHaltOn
The category determines whether the computer will stop if an error is detected during power up.
ꢁNO Errors
ꢁAll Errors
ꢁMid
The system boot will not stop for any error that may be detected
and you will be prompted.
Whenever the BIOS detects a non-fatal error the system will be
stopped.
The system boot will not stop for a keyboard or disk error; it will
stop for all other errors. (Default value)
ꢋClearMem. ECCErrorInfo
ꢁEnabled
ꢁDisabled
Enable Clear memory ECC error information function.
Disable this function. (Default value)
ꢋFatal Erroron portA
ꢁEnabled
Enable Fatal Erre on portA. (Default value)
Disablethisfunction.
ꢁDisabled
50
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
Boot
PhoenixBIOS Setup Utility
Main
Advanced
Security
Server
Boot
Exit
Item Specific Help
+ CD-ROM Drive
+ Hard Drive
Removable Device
MBA V8.1.53 Slot 0100
MBA V8.1.53 Slot 0420
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 5: Boot
*
About This Section: Boot
The “Boot” menu allows user to select among four possible types of boot devices listed
using the up and down arrow keys. By applying <+> and <Space> key, you can promote
devices and by using the <-> key, you can demote devices. Promotion or demotion of devices
alerts the priority that the system uses to search for boot device on system power on.
ꢋBoot Device Priority
` Removable Device / Hard Drive / CD-ROM Drive/
These three fields determines which type of device the system attempt to boot from after
PhoenixBIOS Post completed. Specifies the boot sequence from the available devices. If the
first device is not a bootable device, the system will seek for next available device.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Exit
PhoenixBIOS Setup Utility
Main
Advanced
Security
Server
Boot
Exit
Exit Saving Changes
Exit Discarding Changes
Load Settup Default
Discard Changes
Item Specific Help
Save Changes
F1: Help
Esc: Exit
KL: Select Item
IJ: Select Menu
+ -: Change Values
F5: Setup Defaults
Enter: SelectꢀSub-Menu F10: Save&Exit
Figure 6: Exit
*
About This Section: Exit
Once you have changed all of the set values in the BIOS setup, you should save your chnages and
exit BIOS setup program. Select “Exit” from the menu bar, to display the following sub-menu.
ꢌExit Saving Changes
ꢌExit Discarding Changes
ꢌLoad Settup Default
ꢌDiscard Change
ꢌSave Changes
52
Download from Www.Somanuals.com. All Manuals Search And Download.
BIOS Setup
ꢋExit Saving Changes
This option allows user to exit system setup with saving the changes.
Press <Enter> on this item to ask for the following confirmation message:
Pressing ‘Y’ to store all the present setting values tha user made in this time into CMOS.
Therefore, whenyou boot up your computer next time, the BIOS will
re-configure your system according data in CMOS.
SetupConfirmation
Save configuration changes and exit now?
[Yes]
[No]
ꢋExitDiscarding Changes
This option allows user to exit system setup without changing any
previous settings values in CMOS. The previous selection remain in effect.
This will exit the Setup Utility and restart your compuetr when selecting this option.
Press <Enter> on this item to ask for confirmation message.
SetupWarning
Configuration has hot been saved!
Save before exiting
[Yes]
[No]
ꢋLoad SettupDefault
This option allows user to load default values for all setup items.
When you press <Enter> on this item, you will get a confirmation dialog box with a message
as below:
SetupConfirmation
Load default configuratin now?
[Yes]
[No]
53
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
ꢋDiscard Changes
This option allows user to load previos values from CMOS for all setup item.
When you press <Enter> on this item, you will get a confirmation dialog box with a message
as below:
Setup Confirmation
Load previous configuration now?
[Yes]
[No]
ꢋSave Changes
This option allows user to save setup dat ato CMOS.
When you press <Enter> on this item, you will get a confirmation dialog box with a message
as below:
Setup Confirmation
Save configuration changes now?
[Yes]
[No]
Press [Yes] to save setup daya to CMOS.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Appexdix
Chapter 6 Appendix
6-1: Acronyms
Acronyms
ACPI
APM
AGP
Meaning
Advanced Configuration and Power Interface
Advanced Power Management
Accelerated Graphics Port
Audio Modem Riser
AMR
ACR
Advanced Communications Riser
BIOS Boot Specification
Basic Input / Output System
Central Processing Unit
BBS
BIOS
CPU
CMOS
CRIMM
CNR
DMA
DMI
Complementary Metal Oxide Semiconductor
Continuity RIMM
Communication and Networking Riser
Direct Memory Access
DesktopManagementInterface
Dual Inline Memory Module
DualRetentionMechanism
Dynamic Random Access Memory
DoubleDataRate
DIMM
DRM
DRAM
DDR
ECP
Extended Capabilities Port
Extended System Configuration Data
Error Checking and Correcting
ElectromagneticCompatibility
Enhanced Parallel Port
ESCD
ECC
EMC
EPP
ESD
ElectrostaticDischarge
FDD
Floppy Disk Device
FSB
Front Side Bus
HDD
IDE
Hard Disk Device
IntegratedDualChannelEnhanced
InterruptRequest
IRQ
55
Download from Www.Somanuals.com. All Manuals Search And Download.
GS-SR195V Rack Mount Server
Acronyms
I/O
Meaning
Input / Output
IOAPIC
ISA
InputOutputAdvanced Programmable Input Controller
IndustryStandardArchitecture
LocalArea Network
LAN
LBA
Logical BlockAddressing
LightEmittingDiode
LED
MHz
MIDI
MTH
MPT
NIC
Megahertz
Musical Instrument Digital Interface
Memory Translator Hub
Memory Protocol Translator
Network Interface Card
Operating System
OS
OEM
PAC
POST
PCI
OriginalEquipmentManufacturer
PCI A.G.P. Controller
Power-On Self Test
PeripheralComponentInterconnect
Rambus in-line Memory Module
Special Circumstance Instructions
Single Edge Contact Cartridge
Static Random Access Memory
Symmetric Multi-Processing
SystemManagementInterrupt
Universal Serial Bus
RIMM
SCI
SECC
SRAM
SMP
SMI
USB
VID
Voltage ID
ZCR
Zero Channel RAID
56
Download from Www.Somanuals.com. All Manuals Search And Download.
|