SRCMRU
Hardware Installation and User’s Guide, Version 1.1.3
October 2002
Order Number: 273561-003
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Using the User Documentation Set ...............................................................................................5
Document Formats ......................................................................................................6
About This Guide...........................................................................................................................6
Customer Support Contact Information.........................................................................................6
Regulatory and Certification Information .......................................................................................7
Product Regulatory Compliance..................................................................................7
Product Safety Compliance .........................................................................................7
Product EMC Compliance ...........................................................................................7
Product Regulatory Compliance Markings ..................................................................7
Electromagnetic Compatibility Notices ......................................................................10
Warnings and Cautions...............................................................................................................12
About this Chapter.......................................................................................................................13
Installation Procedures................................................................................................................13
Computer System Hardware Requirements..............................................................13
Installing the IIR Controller ........................................................................................14
Programming the Flash Memory.................................................................................................15
SCSI Termination ........................................................................................................................15
Configurable I/O Controller SCSI Parameters.............................................................................16
Operating System Support ..........................................................................................................18
Supported SCSI Technology.......................................................................................................18
RAID Array Drive Roaming .........................................................................................................20
Optional Features........................................................................................................................21
RAID Controller Drive Limitations (Host, Array, Logical, and Physical).......................................21
Firmware Update Procedure via XROM StorCon.......................................................................23
Firmware Recovery Procedure via Flash Recovery Utility (FRU)...............................................24
Figures
Installing the IIR Controller into a Computer System..................................................................15
Hardware Installation and User’s Guide
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Tables
Configurable Disk Drive SCSI Parameters.................................................................................16
Configurable I/O Controller SCSI Parameters............................................................................16
Hardware Architecture Features ................................................................................................17
Electrical Specifications..............................................................................................................17
Environmental Specifications .....................................................................................................18
Supported SCSI Device Standards ............................................................................................19
RAID Controller Drive Maximum Limitations (SRCMRU) ...........................................................22
4
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
Getting Started
1
Intended Audience
This documentation is intended for users who are experienced in configuring computer
®
systems with new add-in cards or have had previous experience with Intel Integrated
RAID (IIR) Controllers.
Read and adhere to all warnings, cautions, and notices in this guide and the other
documents in the user documentation set supplied with this product.
1.1
Using the User Documentation Set
User documentation for this product is provided in four separate documents:
Installation Quick Start Poster
The Installation Quick Start Poster, or Quick Start Poster, provides a high level view of
installing and configuring a RAID controller. Refer to the accompanying Software Guide
for more detailed information.
Hardware Installation and User’s Guide
The Hardware Installation and User’s Guide, or Hardware Guide, covers instructions for
installing an IIR controller and provides a guide to its features and specifications. For a
particular IIR controller, its hardware guide documents compatible RAID adapters,
supported operating systems, standard features and optional features.
Software Installation and User’s Guide
The Software Installation and User’s Guide, or Software Guide, contains:
• Quick installation of the IIR controller software on a newly created bootable host drive
with commonly used operating systems.
• Detailed instructions covering more complex software installation scenarios for all
supported operating systems.
• Instructions for using the RAID Software Suite, the drivers, tools and utilities of the IIR
controller.
The first part of the software guide provides an overview of RAID technology and its
features. Next, the guide documents various installation procedures for an IIR controller
and the RAID Software Suite, depending on the chosen OS configuration. The software
guide then includes descriptions of the utilities, Storage Console (StorCon) and Storage
Console Plus (StorCon+), to facilitate the configuration of the RAID subsystem. Finally,
the guide provides details of all product features supported by the software and firmware
For further information refer to the Optional Features section of the appropriate hardware
guide since not all features are applicable to all IIR controllers.
Hardware Installation and User’s Guide
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
Clustering Guide
Clustering is applicable only for those RAID controllers that support this feature. See the
Hardware Guide to determine if clustering is supported.
®
The Intel Integrated RAID Controller Clustering Guide, or Clustering Guide, describes
how to set up clustering configurations using IIR Controllers and IIR controller software.
Information on Operating Systems, Cluster functionality, and other system details may be
found in their corresponding system manuals.
1.1.1
Document Formats
All documents, with the exception of the quick start poster, are provided on the CD-ROM
in both PDF and HTML format:
• HTML—To view online HTML documents, Click Documentation from the autorun
menu or open <cdromdrive>:\docs\index.htm.
• PDF—Portable Document Format (PDF) documents can be opened, viewed, and
printed with Adobe* Acrobat Reader* (not provided on the CD-ROM).
1.2
About This Guide
This guide contains three sections:
This chapter covers how to use the different user documents in the user documentation set,
customer support contact information should you need support for this product, and
regulatory and license agreements covering this product.
This chapter contains the procedures for installing the IIR controller into a computer
system.
This chapter covers all the hardware specifications associated with the IIR controller and
its components and any optional RAID features that are supported by the RAID Software.
The Software Guide covers in detail all software features.
1.3
Customer Support Contact Information
[Provided by RAID vendor]
6
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
1.4
Regulatory and Certification Information
Note: This card is intended for use in UL Listed computers or equivalent, that have instructions
detailing installation.
1.4.1
Product Regulatory Compliance
The IIRZN0CHXX (SRCMRU) RAID add-in card, when correctly integrated per this
guide, complies with the following safety and electromagnetic compatibility (EMC)
regulations.
1.4.2
1.4.3
Product Safety Compliance
rd
• CSA C22.2, No. 60950/UL 60950, 3 Edition (US/Canada)
• EN 60 950 (European Union)
• IEC 60 950 (International)
• CE - Low Voltage Directive (73/23/EEC) (European Union)
Product EMC Compliance
• FCC/ICES-003, Class A Emissions (USA/Canada) Verification
rd
• CISPR 22, 3 Edition, Class A Emissions (International)
• EN55022, Class A Emissions
• EN55024: 1998, Immunity
• CE - EMC Directive 89/336/EEC
• VCCI, Class A Emissions (Japan)
• AS/NZS 3548, Class A Emissions (Australia / New Zealand)
• BSMI CNS13438, Class A Emissions (Taiwan)
• RRL, MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea)
1.4.4
Product Regulatory Compliance Markings
The IIRZN0CHXX RAID add-in card will be marked with the following regulatory
markings:
Hardware Installation and User’s Guide
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
UL
US
Listing Marks
C
CE Mark
FCC Marking (Class A)
This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation. Manufactured by Intel Corporation.
Australia C-Tick Mark
8
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
Taiwan BSMI Marking
(Class A)
Korea RRL MIC Mark
In addition, the IIRZN0CHXX RAID add-in card meets the following regulations:
Canada EMC Marking
(Class A)
Hardware Installation and User’s Guide
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
Japan VCCI Marking
(Class A)
1.4.5
Electromagnetic Compatibility Notices
1.4.5.1
FCC Verification Statement (USA)
Product Type: IIRZN0CHXX
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Intel Corporation
5200 N.E. Elam Young Parkway
Hillsboro, OR 97124-6497
Phone: 1-800-628-8686
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
10
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could
void the user’s authority to operate the equipment. The customer is responsible for
ensuring compliance of the modified product.
All cables used to connect to peripherals must be shielded and grounded. Operation with
cables, connected to peripherals that are not shielded and grounded may result in
interference to radio and TV reception.
1.4.5.2
ICES - 003 (Canada)
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux
appareils numériques de Classe Aprescrites dans la norme sur le matériel brouilleur:
“Appareils Numériques”, NMB-003 édictée par le Ministre Canadian des
Communications.
(English translation of the notice above.) This digital apparatus does not exceed the Class
A limits for radio noise emissions from digital apparatus set out in the interference-
causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Canadian
Department of Communications.
1.4.5.3
1.4.5.4
CE Declaration of Conformity (Europe)
This product has been tested in accordance to, and complies with the Low Voltage
Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked
with the CE Mark to illustrate its compliance.
VCCI (Japan)
English translation of the notice above:
This is a Class A product based on the standard of the Voluntary Control Council for
Interference (VCCI) from Information Technology Equipment. If this is used near a radio
or television receiver in a domestic environment, it may cause radio interference. Install
and use the equipment according to the instruction manual.
Hardware Installation and User’s Guide
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
1.4.5.5
BSMI (Taiwan)
The BSMI ID certification number is located on the primary (top) side of the product.
1.5
Warnings and Cautions
This guide and all associated guides in the user documentation set (the Quick Start Guide,
the Hardware Guide, and the Software Guide) should be used by qualified technical
personnel with experience installing and configuring PCI adapter cards.
Read and adhere to all warnings, cautions, and notices in this guide and all the guides in
the user documentation set supplied with this product.
Warnings
• The connection of a non-shielded equipment interface cable to this equipment will
invalidate the FCC certification of this device and may cause interference levels that
exceed the limits established by the FCC for this equipment. It is the responsibility of
the user to obtain and use a shielded equipment interface cable with this device. If the
equipment has more than one interface connector, do not leave cables connected to
unused interfaces unless otherwise instructed to do so in the user manual.
• Changes or modifications not expressly approved by the manufacturer could void the
user's authority to operate the equipment.
Cautions
• Take precautions to prevent electrostatic discharge (ESD) damage before handling the
IIR controller.
• ESD can damage adapter card components. Perform the described procedures in this
guide only at an ESD workstation. If no such station is available, you can provide some
ESD protection by wearing an antistatic wrist strap and attaching it to a metal part of
the computer chassis.
12
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
Hardware Installation
2
2.1
About this Chapter
This chapter provides information on installing the IIR controller, programming the Flash
memory, and general SCSI termination information.
2.2
Installation Procedures
Warning: Do not attempt to insert your RAID controller into any non RAIDIOS-enabled PCI
slot. Doing so may cause damage to your controller and/or your computer. Please
consult your motherboard documentation about availability of RAIDIOS-enabled
PCI slots.
Warning: Shock hazards may be present inside the computer in which this card is being
installed. Disconnect all power cords to the computer before the removal of any
covers.
Follow the warnings noted in your computer’s user manual before installing this board.
ONLY after reinstallation of all the covers should you reconnect the power cords and
power up the computer.
Note: Take precautions to prevent electrostatic discharge (ESD) damage before handling the IIR
controller.
2.2.1
Computer System Hardware Requirements
• Computer with CD-ROM drive (not attached to the IIR controller)
• One available 64bit, 66MHz, universal-keyed RAIDIOS-enabled PCI slot.
• PCI 2.2 compliant System BIOS
Hardware Installation and User’s Guide
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
Figure 2-1. IIR Controller Component Layout
167mm (6.57 inches)
I/O Processor
DS2A1
SDRAM
J1B1
Flash Memory
64Bit PCI Interface
2.2.2
Installing the IIR Controller
1. Power-off the computer system.
2. Disconnect power cord(s) and remove the system cover.
not be representative of your system. Consult your system docs for the exact location of
the RAIDIOS-enabled PCI slot.
4. Connect one end of the SCSI cable to the on-board SCSI connector. Connect the other
end of the SCSI cable to the SCSI drives or drive enclosure.
guide for termination details.
5. Replace the system cover and reconnect power cord(s).
14
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
Figure 2-2. Installing the IIR Controller into a Computer System
RAIDIOS-ENABLED PCI
2.3
Programming the Flash Memory
The IIR controller normally comes ready to be installed into the computer motherboard
immediately. However, you may need to reprogram the RAID firmware that is located in
the flash memory of the IIR controller.
There are 2 options for programming the firmware, Firmware Update or Firmware
Recovery. Use the Firmware Update procedure to overwrite the existing firmware with a
problems with the flash memory, for example, if the current firmware programmed in the
flash is unusable or if a previous firmware update was inadvertently interrupted (see
2.4
SCSI Termination
Termination is a commonly overlooked requirement when connecting SCSI devices
together. When these devices are connected together, the resulting set of devices is
typically referred to as a SCSI bus. SCSI devices such as hard disks and tape drives must
be terminated if they are the last physical devices at either end of the SCSI bus (if nothing
else is actively terminating the end of the bus such as a terminator or backplane). If a
device is inserted into the middle of the SCSI bus, then it (the device itself) should not be
terminated. Only terminate each end of the bus. The modular RAID on motherboard
(MROMB) design lowers cost by utilizing the SCSI controller and connectors that are
integrated into the system’s motherboard. With MROMB, termination occurs on the host
SCSI controller.
Hardware Installation and User’s Guide
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
2.5
Configurable Disk Drive SCSI Parameters
When a SCSI hard disk drive is initialized the first time by the RAID controller, its SCSI
parameters are automatically set to their optimal settings. Most settings are set
automatically and can not be configured manually. To view or configure disk drive SCSI
parameters from the Storage Console, choose Advanced Setup Æ Configure Physical
Devices Æ Select Physical Drive Æ SCSI Parameter/Initialize.
Table 2-1. Configurable Disk Drive SCSI Parameters
Setting/
Value
Parameter
Configuration
Description
Synch.
Transfer
Enabled /
Disabled
This setting when enabled allows the controller to
operate in synchronous transfer mode
Automatic
Allows for the setting of the speed for the SCSI
hard disks (up to 320 MB/sec for U320 drives).
No matter the setting, the SCSI bus will negotiate
the fastest speed up to this setting. Lowering the
setting will force the disk drive to transfer at the
lower speed.
Synch.
Transfer Rate
Speed
(MB/sec)
Automatic
Automatic
Enabling this setting allows for the disk drive to
disconnect from the SCSI bus when it’s not
participating in a transfer. This allows for optimal
bus utilization by all devices on the bus.
Enabled /
Disabled
Disconnect
When enabled, this feature allows the SCSI disk
drive to execute more than one command at a
time.
Tagged
Queues
On / Off
On / Off
Automatic
Disk Read
and Write
Cache
For performance reasons, the Read Ahead and
Write cache of the hard disk drives should always
be on. This is the default setting.
Configurable
2.6
Configurable I/O Controller SCSI Parameters
When the controller starts up, its SCSI parameters are automatically set to their optimal
settings. Manual configuration is not required. However, you can customize I/O SCSI
parameters for each channel on the controller by using the Storage Console menu
Advanced Setup > Configure Controller > Controller Settings.
Table 2-2. Configurable I/O Controller SCSI Parameters
Parameter
Setting/Value
Description
When this is set to On, Domain validation allows for a
cyclical check of the correct data transfer at a given rate for
the respective channel.
Domain Validation
On / Off
For ultra320, the SRCMRU controller supports Basic,
Enhanced, and Margined Domain Validation. For ultra160,
the SRCMRU controller supports Basic and Enhanced
Domain Validation.
16
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Specifications and Features
Hardware Specifications and Features 3
This chapter covers all the hardware specifications associated with the IIR controller and
RAID Software Suite. The accompanying Software Guide covers all implemented
software features.
3.1
IIR Controller Hardware Features
This section provides a summary of the key features, configuration options and support
interface technology supported by the IIR controller.
Table 3-1. Hardware Architecture Features
Component
Feature
I/O Microprocessor
The 80303 processor: 100MHz, RISC 64-bit core
The 80303 IOP supports up to 512 Mbytes of 64-bit 100
MHz ECC SDRAM operating at 66 MHz. It is backward
compatible to support 64, 128, and 256 Mbit SDRAM
technologies. Note: The SRCMRU is limited to 32MB of
embedded memory.
Cache Memory
3.3v, 16Mbit (2 MB) flash memory chip is used to store
the RAID firmware
Flash Memory
I/O interface (PCI)
PCI Transfer Rate
PCI Signaling
RAIDIOS-enabled PCI 2.2 compliant
528MB/second (burst)
Capable of being used in a 5 volt or 3.3 volt slot.
Table 3-2. Electrical Specifications
Attribute
Measurements
Voltage Requirements
+5, 3.3 Volts (all +/– 5% tolerance)
+5V @ 0.25 Amps = 1.25W
+3.3V @ 2.5 Amps = 8.25W
Power Consumption
Hardware Installation and User’s Guide
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Specifications and Features
Table 3-3. Environmental Specifications
Attribute
Condition
Operating 0° to +55° C
Storage -40° to +70° C
Temperature
Humidity
Operating 90% relative humidity
Storage 90% relative humidity
Height: 56 mm (2.20 inches)
Length: 167 mm (6.57 inches)
Form Factor
(physical dimensions)
3.2
Operating System Support
The following operating systems are fully validated and supported:
• Microsoft* Windows* 2000 Advanced Server, Service Pack 2
• Novell* NetWare* 6.0
• SCO* Openserver* 5.0.6 from Caldera*
• Red Hat* Linux* 7.2 (2.4 kernel)
• Caldera OpenUnix* 8.0
• SuSe Linux 7.3 Professional
The following operating systems are supported with limited compatibility validation:
• Windows NT 4.0 Server and Enterprise Server, Service Pack 6a or higher
• Novell NetWare 5.1 (support pack 2a or higher)
• Linux (2.4 kernel)
— Red Hat Linux 7.1
— Debian* Linux 2.2r6
— Caldera Linux 3.1
— Mandrake* Linux 8.1
— TurboLinux* 7.0 Server
• Caldera UnixWare 7.1.1
• FreeBSD* 4.0 and 4.5
• Linux (2.2 kernal)
— Red Hat Linux 7.0
3.3
Supported SCSI Technology
The RAID adapter supports up to 15 SCSI devices per SCSI channel. It supports up to 15
hard disk drives (or 14 hard disks drives if one of the SCSI ID’s is occupied by a SAF-TE
processor) per channel of the SCSI controller (30 disk drives total for an MROMB
application, assuming a dual channel SCSI controller on the motherboard).
18
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Specifications and Features
The SRCMRU firmware supports the following SCSI controllers on the motherboard:
• SCSI Ultra160
— Adaptec* AIC-7899x dual-channel Ultra160 SCSI controller
— Adaptec AIC-7892x single-channel Ultra160 SCSI controller
• SCSI Ultra320
— Adaptec AIC-7901 single-channel Ultra320 SCSI controller
— Adaptec AIC-7902 dual-channel Ultra320 SCSI controller
3.3.1
Supported Hard Drive Technology
The IIR controller supports both Single-ended (SE) and Low Voltage Differential (LVD)
devices but it is recommended that you use only one type of drive technology (SE or
LVD) on any one channel at a time.
The IIR controller supports single-ended drives which operate at up to 40MB/sec
depending upon the speed of the drives attached.
The IIR controller supports Ultra-2 LVD SCSI devices operating at up to 80MB/sec,
Ultra160 LVD SCSI devices operating at up to 160MB/sec, and Ultra320 LVD SCSI
devices operating at up to 320MB/sec.
Note: If both SE and LVD devices are attached to the same channel/bus, the entire bus will
cable length distances that apply to each mode.
The IIR controller is designed to use an Ultra160 or Ultra320 SCSI controller
implementation on the motherboard and is backward compatible with older SCSI hard
Table 3-4. Supported SCSI Device Standards
Maximum Cable
(1)
Length (meters)
Adapter Maximum
Devices per SCSI
Channel
SCSI Drive
Standard
Speed
(MB/Sec)
Bus Width
(Bits)
Single-
Ended
LVD
(2)
(3)
(3)
(3)
(3)
SCSI-1
5
8
8
6
3
8
8
(2)
Fast SCSI
10
20
20
20
40
40
40
40
Fast Wide SCSI
16
8
3
16
8
(2)
Ultra SCSI
1.5
3
(2)
Ultra SCSI
8
N/A
4
(3)
Wide Ultra SCSI
Wide Ultra SCSI
Wide Ultra SCSI
16
16
16
8
N/A
1.5
16
8
N/A
N/A
12
3
4
(2, 4)
(4)
Ultra 2 SCSI
8
Hardware Installation and User’s Guide
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Specifications and Features
Table 3-4. Supported SCSI Device Standards
Maximum Cable
(1)
Length (meters)
Adapter Maximum
Devices per SCSI
Channel
SCSI Drive
Standard
Speed
(MB/Sec)
Bus Width
(Bits)
Single-
Ended
LVD
(4)
(4)
Wide Ultra 2
80
16
16
16
12
12
12
16
16
16
Ultra160 (Ultra 3)
Ultra320
160
320
(4)
(4)
Notes:
1. May be exceeded in Point-to-Point and engineered specific applications.
2. Use of the word "Narrow", preceding SCSI, Ultra SCSI, or Ultra2 SCSI (for example, Narrow
SCSI) is optional.
3. LVD was not defined in the original SCSI standards for this speed. If all devices on the bus
support LVD, then 12-meters operation is possible at this speed. However, if any device on the
bus is singled-ended only, then the entire bus switches to single-ended mode and the distances
in the single-ended column apply.
4. Single-ended is not defined for speeds beyond Ultra.
After Ultra2 all new speeds are wide only.
3.3.2
Support for Non-Hard-Disk-Drive SCSI Devices (Non-Direct-
Access Devices)
The RAID controller will pass through to the host operating system direct access to non-
direct-access SCSI devices which are connected to a SCSI bus (channel) of the RAID
controller. The RAID controller passes through all control of these devices to the host
operating system.
Types of supported non-Direct-Access SCSI devices (this does not cover specific vendors
and models):
• SAF-TE Processors
• Tape Backups
• CD-ROMs
3.4
RAID Array Drive Roaming
Array Roaming allows the user the ability to move a complete RAID array from one
computer system to another computer system and preserve the RAID configuration
information and user data on that RAID array. ††Compatible RAID controllers must
control the RAID subsystems of the two computer systems (see list of compatible
controllers in this section). The transferred RAID array may be brought online while the
target server continues to run if the hard disk drives and disk enclosure support hot plug
capabilities; however, not all operating systems support this feature. The hard disk drives
are not required to have the same SCSI ID in the target system that they did in the original
system that they are removed from. The RAID array drive that is being roamed must not
be of type Private. This includes all non-private host, array, and logical drives.
20
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Specifications and Features
Warning: †† The SRCMRU adapter, with firmware 2.34.yy-Rzzz, is not compatible with all
previous controllers and firmware versions. Do not attempt RAID Array Drive
Roaming between RAID controllers that are not compatible with the SRCMRU
controller. Unpredictable behavior may include, but is not limited to, data loss or
corruption.
Compatible controllers include:
• SRCU42L – Firmware version 2.34.yy-Rzzz
• SRCU31LA - Firmware version 2.3x.yy-Rzzz
• SRCU31A– Firmware version 2.3x.yy-Rzzz
• SRCU32 – Firmware version 2.3x.yy-Rzzz
• SRCMRU – Firmware version 2.3x.yy-Rzzz
• SRCZCR – Firmware version 2.3x.yy-Rzzz
Note: Compatibility refers only to how data and RAID configuration information are written to
the hard disks. Compatible adapters have the same data file format.
3.5
Optional Features
There are no optional features for this product.
3.6
RAID Controller Drive Limitations (Host, Array,
Logical, and Physical)
The following are limitations assuming the following:
• U160 or U320 speed depending on the SCSI controller on the motherboard
• Dual channel SCSI controller
• Cabling that meets U160 or U320 specifications depending on the SCSI controller
Physical drives are limited by the number of SCSI channels being controlled by the
RAID controller. The firmware/software supports a maximum of 15 hard disk drives per
channel (or 14 if one SCSI ID is being occupied by an intelligent enclosure processor).
The maximum number of array drives is limited to 35 by the RAID firmware. The actual
supports channel spanning where an array can consist of physical drives that are attached
to either one or to both channels of the RAID controller. An array drive requires a
minimum of two hard disk drives (or logical drives). Therefore the maximum array
limitation for each RAID controller is the physical drive limit of that RAID controller
divided by two. An array drive can contain (or have reside on it) up to a maximum of 2
host drives.
Hardware Installation and User’s Guide
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Specifications and Features
RAID firmware limits the controller to a maximum of 30 host drives (RAID volumes) per
controller. There is a minimum of at least one host drive per array drive. A host drive can
only be associated with (or reside on) a single array drive. Like array drives, host drives
can reside on hard disk drives that are isolated to a single channel or span both of the
channels of the RAID controller.
Table 3-5. RAID Controller Drive Maximum Limitations (SRCMRU)
Maximum
Per Channel
Maximum
Per Controller
Maximum
Per Array Drive
Maximum
Per Host Drive
Drive Type
30
Physical Disk Drives
15
7
30
30
1
(2 minimum)
RAID Array Drives
RAID Host Drives
15
30
2
22
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Programming
Flash Memory Programming
A
A.1
Firmware Update Procedure via XROM StorCon
The Storage Console (StorCon) is a full-featured monitoring and configuration utility with
a text-based user interface. StorCon manages all aspects of the RAID subsystem as well as
many features of the RAID adapter. Refer to the Software Guide for more details about
StorCon.
You can use StorCon to update the firmware image. The menu option, Firmware Update,
allows you to update the firmware, BIOS and expansion ROM (XROM) StorCon
currently programmed on the flash memory of the IIR controller. Because the Flash-RAM
can be reprogrammed many times, the software modules can be easily updated, without
having to remove the controller from its PCI slot.
The firmware, BIOS and XROM StorCon are part of the file, SRC_RXFW.xxx, where the
file extension xxx indicates the version stepping. The current firmware file can be found
on the RAID Software Suite CD-ROM. To get the latest firmware for the IIR controller,
Note: The Firmware Update option is not available when StorCon is accessing the IIR
Controller remotely.
Follow the procedure below to update the firmware via XROM StorCon.
1. Download the firmware image containing the latest programs/drivers from the
website. Format a 3.5” HD disk (1.44MB) and copy the SRC_RXFW file onto the
disk.
2. With the adapter installed in the system, boot the computer and press <Ctrl>+<G>
when prompted to enter the BIOS version of StorCon.
3. Select the applicable IIR controller and press <Enter>.
4. If the Express Setup menu is displayed, press <F4> to display the Advanced Setup
menu. Select the menu option, Configure Controller and press <Enter>. Insert the
floppy containing the latest firmware file into the floppy disk drive.
5. From the Configure Controller submenu, select Firmware Update and press <Enter>.
6. XROM StorCon automatically searches for the firmware file from the floppy drive, a:\.
After finding the file, StorCon displays the name, description and version of the
firmware. Press <Enter>.
7. StorCon reads and checks the firmware file, then displays a warning. Press <Y> to
confirm the firmware update.
8. StorCon programs the flash eprom.
Hardware Installation and User’s Guide
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Programming
Warning: Do not interrupt the update process to avoid damaging the firmware image in the
Flash. If the firmware is interrupted you will need to follow the firmware recovery
process in the next section.
After StorCon indicates that the update is complete, press any key.
9. The focus returns to the Configure Controller submenu. Press <Esc> several times to
close the menus and press <Y> to quit StorCon.
10.StorCon detects the firmware update and requires a system reboot. Press any key to
reboot.
When the update process has completed, reboot the computer for the change to take effect.
During boot up, the system displays the updated firmware version. You can also relaunch
StorCon and select the applicable IIR controller to view its new firmware version at the
bottom of the console (for example, FW:2.32.00-Rxxx).
You can also use the OS version of StorCon to update the firmware. Refer to the Storage
Console chapter of the Software Guide for more details.
A.2
Firmware Recovery Procedure via Flash Recovery
Utility (FRU)
1. Set the IIR controller’s IOP to Reset (Flash Recovery) mode:
Warning: Shock hazards may be present inside the unit in which this card is being installed.
Disconnect all power cords to the unit before removal of any covers. Follow the
warnings noted in your computer’s user or service manual before installing this
board. ONLY after all the covers are reinstalled should you reconnect the power
cords and power up the unit for the software installation and use.
a. Take all precautions to prevent ESD damage before handling the IIR controller.
b. Power off all system components and disconnect their power cords.
c. Remove the cover from the system to gain access to the RAIDIOS PCI slots.
d. Remove the IIR controller from your system.
e. On jumper block J1B1, move the jumper from position 2-3 to position 1-2 (see
Figure A-1). Re-install the adapter in the RAIDIOS PCI slot in which it was
previously installed.
f. Replace the cover, reconnect all power cords and power up the system.
Figure A-1. Jumper Positions for Flash Update and Recovery
J1B1
1
2
3
1
2
3
Normal-Run
Flash Recovery
24
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Programming
2. Change your computer’s BIOS setting so that your system boots from the CD-ROM.
3. Use the RAID Software Suite CD-ROM to flash the firmware.
a. Boot the computer with the bootable RAID Software Suite CD-ROM that
contains the version of the RAID firmware that you wish to recover.
b. At the ROM-DOS Startup menu, select the option, Flash Recovery Utility, and
press <Enter>.
c. The Flash Recovery Utility detects any IIR controllers that are in reset mode and
lists them in the order that they are found.
Note: Any IIR controllers that are not in reset mode will not be listed. If no
controllers are listed, your controller may not be in reset mode. Shut down the
reset mode.
d. Type a controller number to start the recovery process for the firmware on that
controller. You do not need to press Enter after typing the number. You will see
the messages shown below during a successful recovery. Each message provides
a percent complete status while the action is in progress. The entire process may
take several minutes.
Erasing flash memory
Downloading data to flash memory
Verifying flash content with input file
Flash upload complete
SUCCESS: Operation completed successfully
Download complete in <duration of flash recovery>
4. Reset the jumper to run mode.
a. Power off all system components and disconnect power cords.
b. Remove the system cover.
c. Remove the IIR controller from your system.
d. On Jumper block J1B1 move jumper from position 1-2 to position 2-3 (see
Figure A-1). Reinstall the IIR controller in the RAIDIOS PCI slot in which it was
previously installed. Reconnect the SCSI drives to the adapter card.
e. Replace the cover, reconnect all power cords and power up the system.
5. Change your computer’s system BIOS setting so that your system boots normally (not
from the CD-ROM).
Note: A firmware recovery returns the controller to the default settings.
Hardware Installation and User’s Guide
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash Memory Programming
26
Hardware Installation and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Index
A
adapter hardware
architecture features 17
system requirements 13
D
disk drive connectivity 18
F
flash memory
programming 15
recovering the firmware 24
I
installation
raid adapter 14
warnings and cautions 12
R
raid adapter
hardware features 17
hardware requirements 13
installation 14
intallation procedures 13
optional features 21
system requirements 13
S
scsi termination 15
system requirements
hardware 13
U
user’s manual
intended audience 5
W
warnings and cautions 12
Hardware Installation and User’s Guide
27
Download from Www.Somanuals.com. All Manuals Search And Download.
|