Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
List of Figures..................................................................................................... iv  
List of Tables ...................................................................................................... iv  
About the Intel® RAID Smart Battery...................................................................i  
Installing the AXXRSBBU6................................................................................. 3  
Important Pre-installation Considerations ......................................................................4  
Step-by-step AXXRSBBU6 Installation ..........................................................................4  
Monitoring Battery Backup ................................................................................ 7  
Monitoring BBUs with the RAID BIOS Configuration Utility............................................7  
Using Intel® RAID Web Console 2 .................................................................................8  
Replacing Battery Backup Units........................................................................ 9  
Disposing of Battery Backup Units.................................................................................9  
Battery Backup Unit Specifications................................................................. 10  
Battery Life and Data Retention Time ..........................................................................10  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Figures  
Figure 1. Top and Bottom View of the AXXRSBBU6...................................................................3  
Figure 2. Battery alignment on the add-in Intel® RAID Controllers ..............................................5  
Figure 3. Battery board mounting on RAID controller board........................................................5  
Figure 4. Reinserting an add-in RAID Controller .........................................................................6  
Figure 5. Battery monitoring with the RAID BIOS Utility ..............................................................7  
Figure 6. BBU information in RWC2 ............................................................................................8  
List of Tables  
Table 1. Battery Backup Unit Specifications..............................................................................10  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About the Intel® RAID Smart Battery  
Intel® RAID Controllers and Intel® Integrated Server RAID Modules provide reliability, high  
performance, and fault-tolerant disk subsystem management. A complete fault-tolerant strategy  
requires protection for all data, including the unwritten cached data in the RAM cache. If power is  
lost, the data in RAM is lost. To avoid this data loss, a battery can be added to supply power to the  
RAID RAM during an AC power outage or if the AC power cord is removed.  
A battery backup unit protects the integrity of the cached data on Intel RAID controllers by  
providing backup power if there is a complete AC power failure or a brief power outage. The Intel  
RSBBUs provide an inexpensive alternative to using an uninterruptible power supply (UPS) or act  
as a second level of fault tolerance when used in conjunction with a UPS.  
The cache memory available on Intel controllers can improve overall system performance. Writing  
data to the controller’s cache memory is much faster than writing it to a storage device. Write  
operations appear to complete very quickly at the software application level. The Intel RAID  
controller then writes the cached data to the storage device when system activity is low or when the  
cache is getting full. The risk of using write-back cache is that the cached data can be lost if the AC  
power fails before it has been written to the storage device. This risk factor is eliminated when the  
Intel RAID controller has an onboard BBU.  
The Intel RSBBUs monitor the voltage level of the DRAM modules installed on the Intel RAID  
controller. If the voltage drops below a predefined level, the battery backup module switches the  
memory power source from the Intel RAID controller to the battery pack attached to the Intel RAID  
Smart Battery Backup Unit (RSBBU). As long as the voltage level stays below the predefined  
value, the Intel RSBBU provides power for memory. If the voltage level returns to an acceptable  
level, the RSBBU switches the power source back to the Intel RAID controller, and all pending  
writes to storage devices are completed with no data loss.  
A smart battery backup unit (BBU) has built-in functionality to charge the battery pack  
automatically and to communicate battery status information such as voltage, temperature, and  
current to the host computer system.  
The AXXRSBBU6 is a smart battery back up module using LiON technology that is compatible  
with a backup auxiliary power source. Battery charging and recharging take place automatically.  
The AXXRSBBU6, which features LiON battery cell technology, mounts directly to the following  
Intel® RAID Controllers using a small board-to-board connector (daughtercard):  
Intel® RAID Controller SRCSASBB8I  
Intel® RAID Controller SRCSASLS4I  
1
Intel® RAID Smart Battery User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Instructions  
Read all caution and safety statements in this document before performing any of the instructions.  
See Intel Server Boards and Server Chassis Safety Information at  
Wichtige Sicherheitshinweise  
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine  
der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-  
Serverplatinen und -Servergehäusen unter  
重要安全指导  
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。  
Server Boards and Server Chassis Safety Information(《Intel  
服务器主板与服务器机箱安全信息》)。  
Important Safety InstructionsConsignes de sécurité  
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document  
avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety  
010770.htm.  
Instrucciones de seguridad importantes  
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar  
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en  
WARNINGS  
Server power on/off: The push-button on/off power switch on the front  
panel of the server does not turn off the AC power. To remove AC power  
from the server, you must unplug the AC power cord from either the power  
supply or wall outlet.  
Hazardous conditions—power supply: Hazardous voltage, current, and energy levels  
are present inside the power supply enclosure. There are no user-serviceable parts  
inside it; servicing should only be done by technically qualified personnel.  
2
Intel® RAID Smart Battery User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the AXXRSBBU6  
Figure 1 displays the top and bottom views of the AXXRSBBU6. The battery pack is mounted on a  
daughtercard which mounts to the RAID controller. Take note of the location of the J2 connector  
(5) which plugs into the Intel® RAID Controller and the 3 standoffs (2) and 6 screws (3). Only the  
top side of the daughtercard will be visible after installation onto the RAID controller.  
Figure 1. Top and Bottom View of the AXXRSBBU6  
1.  
2.  
3.  
4.  
5.  
6.  
J4 battery pack harness connector  
J5 board-to-board connector  
J2 connector  
Battery pack harness  
Screws  
Spacers (stand-offs)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Pre-installation Considerations  
Warning: Always ground yourself and/or use a ground strap before touching the RAID controller  
or the RSBBU. Perform all installation work at an ESD-safe workstation. Use an ESD-safe Phillips  
screwdriver set to a maximum torque of 2.25 inch pounds, and be sure the screwdriver is centered  
in the screw to avoid damaging the screw head. If you exceed the maximum torque specification,  
you may damage the board, connectors, or screws, and you will void the warranty of the board.  
The batteries in the RSBBUs must recharge for at least six hours during fast charge under normal  
operating conditions.  
To protect your data, Intel recommends that you set the RAID controller Write Policy to write-  
through until the battery unit is fully charged. When the battery unit is charged, you can change the  
Write Policy to write-back to take advantage of the performance improvements of data caching.  
The maximum ambient temperature for the battery pack is 45°C. Note: The temperature of the  
battery pack is generally 15–20 degrees higher than the ambient temperature during fast charge.  
Therefore, to complete the fast charge cycle, ambient temperature should be less than 45°C. If the  
ambient temperature exceeds 45°C, the fast charge cycle will terminate prematurely, thus  
preventing the battery pack from reaching a fully charged state.  
Step-by-step AXXRSBBU6 Installation  
Follow the steps in this section to install the AXXRSBBU6 on the Intel® RAID Controller  
SRCSASBB8I or SRCSASLS4I.  
A. If the RAID controller is already installed in a computer, follow these steps to remove it before  
you install the AXXRSBBU6:  
1. Shut down the computer, turn off the power, and unplug the power cord(s).  
2. Remove the cover from the computer and ground yourself before touching the RAID  
controller. Carefully unplug all cables going to the RAID controller. On the data cables,  
depress the silver spring at the connector end to make sure the 2 tiny catches release.  
3. Following the instructions in User’s Guide for your server, carefully remove the RAID  
controller from its slot. On the Intel® Server Platform S7000FC4UR, you must remove  
the processor air baffle and push back on the guide latch while pulling up on the riser  
card.  
4. Place the RAID controller on a flat, clean, static-free surface.  
B. Follow these steps to install the AXXRSBBU6 on the RAID Controller.  
1. Ground yourself, and remove the AXXRSBBU6 from the package.  
2. Insert the battery pack harness connector (number 4 in Figure 1) at the end of the colored  
wires into the 5-pin J4 connector (number 1 in Figure 1) on the backside of the  
AXXRSBBU6.  
3. Make sure the 3 standoffs and 6 screws and the Phillips screwdriver are easily available  
during the following steps.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Remove the protective metal cover from the battery connector on the RAID controller  
card. (J10 on the Intel® SRCSASBB8I and Intel® SRCSASLS4I.)  
5. On the Intel® RAID Controller SRCSASBB8I and the Intel® RAID Controller  
SRCSASLS4I, place the RAID controller with the components facing up.  
Figure 2. Battery alignment on the add-in Intel® RAID Controllers  
6. Hold the AXXRSBBU6 so that the battery side is up and the three screw holes align.  
Figure 3. Battery board mounting on RAID controller board  
7. Place the three standoffs (#6 in Figure 1) between the two cards in the three screw holes.  
8. Carefully press the AXXRSBBU6 onto the RAID controller, so that the two connectors  
shown in Figure 3 are firmly joined.  
On the Intel® RAID Controller SRCSASBB8I and the Intel® SRCSASLS4I, use the  
J10 connector.  
9. Secure the AXXRSBBU6 to the RAID controller with the 6 provided Phillips (2-56)  
screws (#5 in Figure 1). The standoffs are threaded at both ends and a 2-56 screw goes  
into each end. (Place 3 in from the battery side and 3 in from the RAID controller side.)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Caution: Center the screwdriver carefully to avoid stripping the  
screwhead. Do not over-tighten the screws. The maximum recommended  
torque is 2.25 inch pounds.  
C. Place the Intel® RAID Controller back into the server  
1. Align the RAID controller with the PCI Express* slot.  
2. Press down gently, but firmly, to ensure that the RAID controller is properly seated in the  
slot. The bottom edge of the RAID controller must be flush with the slot.  
Caution: Never apply pressure to the AXXRSBBU6 when you insert the  
RAID controller. Instead, press down only on the top edge of the RAID  
controller.  
Figure 4. Reinserting an add-in RAID Controller  
3. Attach the cables, as needed, to the connectors on the Intel® RAID controller.  
For the Intel® Server Platform S7000FC4UR only: Install the processor air baffle.  
4. Replace the computer cover and reattach the power cord(s).  
.
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Monitoring Battery Backup  
Multiple utilities are available to display and configure BBU information including recharge count.  
When you replace a BBU, you should reset this counter to zero. Intel recommends that you replace  
the BBU once per year or after 500 recharge cycles, whichever comes first.  
Note: This chapter describes only the BBU-related features of the Intel utility programs. For  
complete information on these utilities, see the Intel® RAID Software User’s Guide.  
Monitoring BBUs with the RAID BIOS Configuration Utility  
The Intel® RAID BIOS Console configures disk arrays and logical drives. It is independent of the  
operating system and accessed at server start up by pressing <Cntrl> <G>  
To view the BBU information, follow these steps:  
1. At boot, press <Cntrl><G> when prompted.  
2. In the RAID BIOS Console, choose “Adapter Properties” on the main menu.  
3. Click Next to view the second Adapter Properties screen.  
4. In the Battery Backup field at the top left of the screen, click the word “Present”.  
Figure 5. Battery monitoring with the RAID BIOS Utility  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Most of the Battery Module properties are view-only. In the lower right panel of the RAID BIOS  
Console there are two properties that can be changed. (Intel recommends that you leave these  
properties at their default settings.)  
Learn Delay Interval – default 30 days  
Auto Learn Mode – default Auto  
Note: The learning cycle is a battery calibration operation performed by the controller periodically  
to determine the condition of the battery.  
Using Intel® RAID Web Console 2  
The status of all BBUs connected to controllers in the server is visible in Intel® RAID Web Console  
2 by selecting the Physical tab in the left panel. To see the battery, select the Controller. The  
Battery Backup Unit will appear as the last item on the list under that controller. An icon (small  
rectangle or red dot) will appear in the left pane to indicate the BBU status. The rectangle indicates  
normal operation, the red dot indicates the BBU has failed.  
Figure 6. BBU information in RWC2  
The BBU properties include the following:  
The number of times the BBU has been recharged (Cycle Count)  
The full capacity of the BBU, plus the percentage of its current state of charge, and the  
estimated time until it will be depleted  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
The current BBU temperature, voltage, current, and remaining capacity  
The estimated time until the battery is fully charged (only if the battery is charging)  
Replacing Battery Backup Units  
Intel recommends that you replace BBUs once a year or after 500 recharging cycles, whichever  
comes first. The warranty on the battery pack is for one year. After you install a new BBU, use one  
of the Intel configuration utilities to reset the battery recharge cycle counter to zero. For  
instructions, see Chapter 3, “Monitoring BBUs with the Intel Configuration Utilities.”  
Disposing of Battery Backup Units  
WARNING: Do not damage the battery pack in any way. Toxic  
chemicals can be released if it is damaged.  
The material in the battery pack contains heavy metals that can contaminate the environment.  
Federal, state, and local regulations prohibit the disposal of rechargeable batteries in public  
landfills. Be sure to recycle the old battery packs properly. Intel reminds you that you must comply  
with all applicable battery disposal and hazardous material handling laws and regulations in the  
country or other jurisdiction where you are using the BBU.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Battery Backup Unit Specifications  
Table 1. Battery Backup Unit Specifications  
Battery Technology  
LiON (Lithium ION) 1 cell  
10–45°C ambient temperature  
20% to 80% humidity non-condensing  
Battery Operating Environment  
Depends on storage time,:< 30 days: 0–50 °C  
30–90 days: 0–40 °C ‘; > 90 days: 0–30 °C  
Battery Storage Temperature  
Fast Charge Current  
Battery Voltage  
Mechanical  
500mAH using charge circuitry card  
Nominal OCV: 3.7 V  
2.611 inches x 2.122 inches  
700 mAH  
Battery Capacity  
Memory Technology  
DDR2 SDRAM (1.8 V)  
Typical: ~3 hours to charge from 1.8V OCV to 3.7V OCV  
Completely depleted: 8 hours  
Battery Charge Time  
Battery Shelf Life  
Battery Operational Life  
Supported Cache Memory  
Memory  
1 year  
Intel provides a 1 year warranty on the AXXRSBBU6.  
128 - 512 Mbytes  
DDR2 SDRAM 667 MHz (1.8V), max 40-bit bus width  
MTBF (Electrical Components) 2,490,772 hours at 40° C  
Temp monitoring via I2C interface. Supports v1.1 “Smart Battery  
System Manager”  
Smart Battery Monitoring  
Ability to detect the presence of an external auxiliary power source.  
Circuitry automatically chooses aux power, defers discharge until aux  
power is removed or exhausted. Auxpower increases the DRT ratings  
Auxiliary Power  
Battery Life and Data Retention Time  
The Intel utilities display a counter showing the number of times a BBU has been recharged. When  
you replace a BBU, you should run the utility program and reset this counter to zero for the new  
BBU. Intel recommends that you replace the battery pack on the BBU once a year or after 500  
recharging cycles, whichever comes first. The warranty on the battery pack is for one year.  
The data retention time is 72 hours (low power) if using the RAM shown below. This rating is  
approximate and can vary based on battery load, ambient temperature, and number of discharge  
cycles associated with the battery.  
256 Mb using (3) 64Mx16 DDR2  
128 Mb using (3) 32Mx16 DDR2  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Remote Starter 3524832 User Manual
Intellinet Network Solutions Switch 523578 User Manual
Invacare Mobility Aid Excel User Manual
JBL Portable Speaker DS35 User Manual
Katadyn Water Dispenser 8013418 User Manual
Kawasaki Cordless Saw 840068 User Manual
Kenmore Cooktop 7904055 User Manual
Kenwood Marine Radio TS 570D User Manual
King Kutter Spreader S ATV 180 U User Manual
Korg Musical Instrument Trinity User Manual