USE & CARE INSTRUCTIONS
S
tart
Ultrasonic Digital
Humidifier
Remanufactured
English
Spanish
E - 1
S - 1
Model No. R3010
30-Day Limited Warranty
1.866.603.5900
Date Purchased
month ________
year _________
E-1
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNINGS
This product should be used only in accordance with the specifications outlined in this manual.
Usage other than what has been specified here may result in serious injury.
Make sure the unit is unplugged.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Disassembly, repair or remodeling by an unauthorized person may result in serious harm.
Do not use if plug is damaged or loose.
Keep this product out of the reach of children and away from pets.
Be careful not to put water in the humidity spout.
Before filling or cleaning the unit, make sure it is unplugged.
Once the humidifier has been turned on, do not move it.
Do not move when in operation.
Do not remove the water tank from the unit while it is on.
Do not handle the adapter plug with wet hands.
Do not excessively bend, twist or pull the power cord.
Avoid placing this product where the humidity is pointed directly at an electrical object.
Do not directly inhale the humidity.
Do not place this product on a sloped or unstable surface.
When not in use, unplug the unit.
Do not fill the water tank with hot or boiling water.
Do not use this product in direct sunlight, or near a gas stove or heater.
Do not use if the water tank becomes cracked or damaged.
Do not keep this product running for an extended period of time.
Do not clean the unit or water tank with detergents or chemicals of any kind.
Do not use this product near any other electronic device.
Do not cover the humidity opening at any time during use.
Do not use this product near a sink.
2. Open the tank lid, turning it to
the left.
1. Separate the tank from the body
of the unit.
3. Pour cool, clean water directly
into the tank. Do not pour anything
but water into the water tank.
4. Close the tank lid, turning it to
the right.
Do not drink water from the water tank.
Do not place this product on an absorbent surface.
Do not pour anything but water into the water tank.
Failure to comply with the warnings listed above may result in electric shock or serious injury.
5. Attach the tank to the body of
the unit.
E-4
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
The programmable mode allows you to set the timer to turn the humidifier both on/off
at a daily predetermined time. This mode also allows the clock to be programmed.
1. Power Button
Before turning on make sure there is water in the unit.
Press the Power Button.
FIRST TURN POWER BUTTON ON.
Power
Done
set
S tart
S top
Time
r
2. Warm or Cool Mist Button
Hour
Select/Set
Minute
Press to select warm or cool mist. Water
temperature is maintained at room temperature for cool
setting and 80 degrees for warm.
S p
C
Program Start
Cool/W arm
1. Push Select/Set Button until "START" is blinking on display.
2. While "START" is blinking, select the desired start time using Hour and
Minute buttons (AM or PM as indicated).
3. Spray Control Button
3. Select Cool/Warm preference.
4. Select Spray Control preference.
When you press the Spray Control Button
there are four options to choose from:
Press once for WEAK
Dim
5. "START" indicator will remain lit once programmed.
Press twice for MIDDLE
Program Stop
Press three times for STRONG
Spray
Control
1. Push Select/Set Button until "STOP" is blinking on display.
2. While "STOP" is blinking, select the desired end time using Hour and
Minute buttons (AM or PM as indicated).
Press four times for TURBO
*You will notice the lights get higher as the spray increases.
3. "STOP" indicator will remain lit once programmed.
4. To cancel program, press and hold select/set button for two seconds
(START and STOP buttons will not be lit).
4A. Light Options - Display Button
Press the Display Button to turn the display lights ON or OFF.
Clock Set
Display
1. Clock must be set in order for timer to work properly.
2. Push Select/Set Button until "TIME" is blinking on display.
3. Select actual time using Hour and Minute Buttons (AM or PM as indicated).
4B. Light Options - Night Light Feature
Press the Lamp Button at the top of the unit to illuminate
the night light feature.
Lamp
5. Water Refill Button
When the Water Refill Button lights up it is time to refill
the water tank.
E-7
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
Always unplug the unit before servicing it in any way.
PROBLEM
SOLUTION
The temperature of the water remaining in the unit after use may be HIGH.
Do not submerse the unit in water, or allow water to enter anywhere on the unit
except the designated water tank.
Water vapor & humidity are
not produced.
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
Tank Installation: Make sure the water tank is
correctly attached. Make sure spring on tank
cap moves freely when pushed.
INSIDE THE BODY OF THE UNIT
Pour excess water out of the unit, but do not allow it to enter the hole where the water
vapor comes out. Wash out the unit with fresh water, using the cleaning brush and a
soft cloth as needed.
Air blows but water vapor is
not produced.
Excessive Water: Remove a certain amount of water
from the tank.
OUTER SURFACE OF THE UNIT
Wipe the surface of the unit with a soft, damp cloth if needed.
The desired humidity is lower than the current tem-
perature: Increase the desired humidity.
WATER TANK
If water spots remain in the water tank, wipe the inside with a soft cloth.
DO NOT use soap or detergents.
Detergent residue in the tank: Wash the tank out and
try again.
AIR FILTER
The surface of the ultrasonic metal disk may be dirty:
Wipe it off with a dry, soft cloth. Clean with diluted
vinegar.
Gently wipe away debris from the filter with a soft cloth.
This filter does NOT need to be replaced.
Humidity level is low.
The water in the unit is too cold: Replace with cool,
but not cold water.
ULTRASONIC DISK
Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly remove build up
and deposits from this area (Fig. 2). Diluted vinegar will help to prevent this build up.
Warm humidity is not produced.
It may take 10-15 minutes before warm
humidity is created. The mist may not feel
warm to the touch.
Check to see if base of unit feels warm to the touch.
If so then warm mist is being produced.
Fig. 2
Fig. 1
The humidity has a bad smell.
Poor maintenance or dirty water: Clean the product
thoroughly, and fill it with fresh water.
White dust is forming on
nearby furniture.
Hard water will deposit a certain amount of
dust. Dust in the air settles because of the
added humidity in the room.
•
•
•
Fully dry the inside and outside of the unit before storing it.
DO NOT leave water in the unit.
Store in a cool, dry place.
*Use distilled water if this becomes a nuisance.
E-9
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
|