System Configuration Guide V.6
(November / 1999)
Notes ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P2
teamserver HS900 -----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P9
teamserver M800 series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P11
teamserver L800 series ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P13
teamserver G800 series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P14
teamserver C800 series---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P15
teamserver C300 series---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P16
teamserver C350ie ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P17
teamserver Network Cards-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P17
teamserver Internal Devices ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P18
teamserver External Devices --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P19
teamserver Rackmount ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P20
Hardware ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P21
Index
Key to
The numbers on the left hand side of each
page correspond to the various options
available with teamservers as follows :
CPU slot
RAM module slot
3.5 inch HDD Bay
5 inch Bay
RS-232C
Or
And
PCI slot
ISA slot
Redundant PSU
Others
1
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Mounting additional memory
(HS900)
A memory board with 16slots is standard equipment and up to 16GB memory can be mounted. When you use over 16memory slots, an additional
Memory Board (GP5-RB201) is required. When using two memory boards in HS900, the same memory size must be mounted on each board.
(M800i)
Memory must be expanded in bank units by mounting four similar capacity DIMMs in one bank. DIMMs must also be mounted in ascending order of
memory capacity alternately on the two RAM base cards.
(L800i)
Mount the same capacity DIMM's in units of four. (Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed)
Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (J1 to J4) to bank D (J13 to J16)
(G800i/C800i/C300i)
The motherboard has four slots for RAM modules (including standard equipment), install RAM modules in slot number order. (teamserver C3xxi
has three slots)
Additional PSU in G800i
When a DLT unit (GP5-DL351) is mounted, an additional PSU (total two PSU) is required.
The restriction of the mount of 2 CPUs, 5HDD or 3 PCIs is cancelled.
S.M.A.R.T.function
S.M.A.R.T. function is available in the conbinations shown below:
:
Corresponds , x:Does not correspond , -:N/A
●
Internal Hard disk units
SCSI Hard disks
Hard disk cabinet
GP5UR1DC4/GP5MS622A
RAID card
IDE
Standard Standard
equipment equipment
Models
SCSI card
SCSI card
RAID card
GP5-125 GP5-126 GP5-127 GP5U141GP5U142 GP5-143 GP5-144 GP5-146 GP5-125
GP5-126
GP5-127
GP5U141
GP5-144
GP5-146
C300i (GP5C300-375)
C300i (GP5C377-379)
C800i
●
●
-
-
●
-
-
●
-
-
-
-
-
x
x
x
-
-
-
●
●
●
-
-
-
-
-
●
-
-
-
-
-
-
x
x
x
x
-
-
-
-
-
●
-
●
●
-
-
-
-
●
-
-
-
G800i
-
-
-
x
●
●
●
●
●
L800i
-
-
-
●
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
●
●
●
●
●
●
-
-
-
-
-
-
●
●
●
-
-
-
●
●
●
●
●
●
M800i
HS900
●
-
●
3
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Hard disk cabinet/RAID card/SCSI card
●Hard disk cabinet
GP5MS622A: Up to four can be connected to C300i, C800i, G800i and L800i.
: Up to six can be connected to M800i.
Note: The Operating System must be installed on an internal hard disk.
●RAID card (GP5U141/GP5-144/GP5-146)
Up to two Hard disk cabinets can be connected with one RAID card.
(Up to three can be connected with one GP5-144 card)
When connecting two GP5MS622A, GP5-144 RAID card is reguired on G800i, L800i, M800i and HS900.
One GP5U141 cannot be used to connect external disk array (Hard disk cabinet) and internal disk array.
One GP5-146 in G/L800i cannot be used to connect external disk array (Hard disk cabinet) and internal
disk array.
One RAID card can not be used for botn internal and external array configuration. 2 RAID cards are
reguired in this case.
GP5-144/146 can only be used with GP5-144/146, they cannot be mixed with
GP5U141/142/-143.
Up to two GP5-146 can be used for internal array configuration in G800i.
When connecting three RAID cards in G800i, the internal HDD must be connected using GP5-144.
●RAID card (GP5U142/GP5-143)
Only for use with internal HDD.
Only one RAID card can be used per server.
●SCSI card (GP5-125/GP5-126/GP5-127)
Internal and external devices cannot be connected to the same SCSI card.
Maximum number of daisy chain connections allowed :
(1) Up to four external devices (but not Hard disk cabinets) can be connected by daisy chain.
(2)Only one Hard disk cabinet can be connected. (Daisy chain connection is not available)
Disk array configuration
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• Physical pack
A collection of physical HDDs comprising a RAID.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• Logical drive
• Partition
Logical drive (ex. D: ) seen by the Operating System.
One of the logical access units into which a logical drive is divided.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
Physical pack
HDD
HDD
HDD
HDD
Logical drive A
Logical drive B
* Drives can be divided into partition.
Partition 1
Partition 2
Logical drive C
<Restrictions>
(1) Physical pack must contain the same type(size) of HDDs.
(2) Maximum logical drive size is 2TB (GP5U141/U142/-143/-144/-146).
4
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
(3) The number of HDDs comprising a physical pack is as shown below.
RAID Level
Discription
HDDs
Capacity of logical drives
The data is broken down into
blocks,each on a separate disk
drive
The capacity of logical drive is
-
RAID 0
2~8
2
same as the capacity of
(
)
connected HDD.
The capacity of the logical
drive is half the capacity of
connected HDD.
Duplicates the disk and writes
the same data onto two disks.
-
-
-
RAID 1
RAID 5
RAID 6
)
(
The data is broken down into
blocks and each blocks is
written together with parity
bits on a separate disk drive.
The capacity of each logical
drive is the number of
connected HDDs - 1).
3~8
3~8
)
)
(
(
The capacity of each logical
drive is the half the capacity of
connected HDD.
Duplicates the disk and broken
down into blocks, each on a
separate disk. (RAID0+1)
(GP5-143/144)
(4) The same RAID level must be use when dividing a physical pack into a number of logical drives.
(5) A physical pack must contain only HDDs which are connected by the same RAID card.
(6) A RAID card can support more than one physical pack. ( even if different RAID levels)
(7) Internal and external array devices cannot be connected to the same RAID card. (except for M8xx)
Additional bus-slots
The number of bus-slots which can be used depends on each model.
Product
HS900
Number of standard bus-slots
Product ID
GP5T9A32R
REMARKS
PCI(64bit-66MHz)x4
PCI(64bit-33MHz)x6
Two PCIs(64bit-33MHz) are used for standard LAN card and
standard RAID card.
GP5T9A22R
M890ie
M880ie
PCI(64bit)x5
PCI(32bit)x5
PCI/ISA(32bit)x1
GP5M895AL
GP5M885AL
GP5M895BL
GP5M885BL
LAN card is mounted in a PCI(32bit)slot.
LAN card is mounted in a PCIslot.
All of the slots are available
L890ie
L880ie
L870ie
PCIx6
PCI/ISAx1
GP5L895L
GP5L885L
GP5L875L
GP5L895LR
GP5L885LR
GP5L875LR
G870ix
G870ie
G870i
PCIx4
PCI/ISAx1
ISAx1
GP5G879L
GP5G878L
GP5G877L
GP5G879LR
GP5G878LR
GP5G877LR
C870ix
C870ie
C870i
PCIx3
ISAx2
GP5C876
GP5C875
GP5C871
GP5C855
GP5C876R
GP5C875R
GP5C871R
GP5C855R
All of the slots are available
C850ie
C370ix
C370ie
C370i
PCIx4
ISAx1
GP5C379
GP5C378
GP5C377
GP5C355
All of the slots are available
C350ie
5
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Number of mountable optional cards
HS900
M800i
Maximum
number of
Maximum
number of cards
mounted
Cards
Product ID
Bus
Total
Cards
Product ID
Bus
Total
5
REMARKS
REMARKS
cards mounted
RAID card
(Ultra2 Wide LVB)
RAID card
(Ultra2 Wide LVD)
Standard
equipment
PCI64
PCI64
PCI64
1
7
7
GP5-144
GP5-146
PCI64
PCI64
5
4
RAID card
(Ultra2 Wide LVD)
RAID card
(Ultra2 Wide LVD)
GP5-144
GP5-146
8
RAID card
(Ultra2 Wide LVD)
SCSI card
(Ultra2 Wide LVD)
GP5-127
PCI64
PCI64
5
2
SCSI card
(Ultra2 Wide LVD)
SCSI card
(Ultrawide Diff)
GP5-127
PCI64
PCI64
6
2
GP5-123
For external disk array
SCSI card
(Ultrawide Diff)
GP5-123
For external disk array
Fibre Channel Card
GP5-FC101
PCI64
PCI64
PCI32
2
1
3
2
4
LAN card (1000Base-SX) GP5-183
Fibre Channel Card
GP5-FC101
PCI64
PCI64
PCI64
2
1
3
2
4
LAN card (100Base-TX) GP5-185
LAN card (1000Base-SX) GP5-183
Standard
LAN card (100Base-TX) GP5-185
LAN card (100Base-TX) equipment
PCI32
1
1
Mounted in PCI slot3(fixed)
Standard
Server Monitor Module GP5USM102 PCI32
1
LAN card (100Base-TX) equipment
PCI64
1
1
* Up to six cards can be mounted when an ISA card is used.
Server Monitor Module GP5USM103 PCI64
1
L800i
G800i
Maximum
Maximum
number of
cards mounted
number of cards
Cards
Product ID
Bus
Total
Cards
Product ID
Bus
Total
REMARKS
REMARKS
mounted
SCSI card
SCSI card
(Ultrawide Diff)
GP5-123
GP5-127
PCI
PCI
2
For external disk array
(Ultrawide Diff)
GP5-123
GP5-127
PCI
PCI
2
3
For external disk array
SCSI card
(Ultra2 Wide LVD)
GP5-127can beused to connect internal
SCSI devices(GP5-DL351,GP5-ML301).
SCSI card
(Ultra2 Wide LVD)
Use for external SCSI devices
3
3
RAID card
7*
RAID card
(Ultra2 Wide LVD)
RAID card
(Ultra2 Wide LVD)
GP5-144
GP5-146
PCI
PCI
3
2
(Ultrawide SE)
GP5U141
GP5U142
GP5-144
GP5-146
PCI
PCI
PCI
PCI
2
1
3
2
Internal/external array configuration
Only for internal array configuration
RAID card
(Ultrawide)
3
RAID card
(Ultra2 Wide LVD)
Internal/external array configuration
Cannot be used with GP5U141/142
5
Fibre Channel Card
GP5-FC101
PCI
PCI
PCI
PCI
2
RAID card
(Ultra2 Wide LVD)
Internal/external array configuration
Cannot be used with GP5U141/142
LAN card (1000Base-SX) GP5-183
LAN card (100Base-TX) GP5-185
1
4
It must be mounted in PCI-A2
3
Fibre Channel Card
GP5-FC101
PCI
2
Standard
LAN card (100Base-TX) equipment
1
Mounted in PCI-A1(fixed)
LAN card (1000Base-SX) GP5-183
LAN card (100Base-TX) GP5-184
Server Monitor Module GP5USM102
PCI
PCI
PCI
1
3
1
3
Server Monitor Module GP5USM102
PCI
1
It must be mounted in PCI-A3
* Up to six cards can be mounted when an ISA card is used.
C800i
C300i (GP5C377-379)
Maximum
Maximum
number of
number of cards
mounted
Cards
Product ID
Bus
Total
3
Cards
Product ID
Bus
Total
3
REMARKS
REMARKS
cards mounted
RAID card
(Ultrawide SE)
GP5U141
GP5-143
GP5-125
PCI
PCI
PCI
2
Internal/external array configuration
Only for internal array configuration
Only for external SCSI devices
SCSI card
GP5-126
GP5-127
GP5U141
GP5-143
PCI
PCI
PCI
1
3
2
2
RAID card
(Ultrawide SE)
1
3
SCSI card
RAID card
(Ultrawide SE)
SCSI card
Internal/external array configuration
RAID card
(Ultra2 Wide LVD)
LAN card (1000Base-SX) GP5-183
LAN card (100Base-TX) GP5-185
Server Monitor Module GP5USM102
PCI
PCI
PCI
1
3
1
3
PCI
PCI
PCI
1
3
1
LAN card (100Base-TX) GP5-185
3
1
Server Monitor Module GP5USM102
C300i (GP5C300-375)
Maximum
number of
cards mounted
Cards
Product ID
Bus
Total
3
REMARKS
SCSI card
GP5-125
GP5U141
PCI
PCI
3
2
RAID card
(Ultrawide SE)
Internal/external array configuration
Only for internal array configuration
(Cannot be used with GP5-143)
RAID card
(Ultra2 Wide LVD)
Only for internal array configuration
(Cannot be used with GP5U142)
GP5-143
PCI
PCI
PCI
1
3
1
LAN card (100Base-TX) GP5-185
3
1
Server Monitor Module GP5USM102
6
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
The differentiation between current models and new models
1. Connectivity/Use of new product options with older models
I. The figure below indicates the applicability of new options on previous (released before August, 1999) models
Product
Option
Product ID
Applicable
to older
O
Remarks
Figure1
Hard disk drive-9GB
Hard disk drive-9GB
Hard disk drive-18GB
Hard disk drive-18GB
GP5-HD9G3
GP5-HD9G3B
GP5-HD8G1
GP5-HD8G1B
Please refer to Figure2
Please refer to Figure2
O
O
O
C300series
Hard disk drive-13GB
LAN card
GP5-HD3E1
GP5-185
O
O
X
Successor of GP5-182/184
SCSI card
GP5-127
SCSI card
GP5-126
X
RAID card
GP5-143
O
X
However, used as Ultrawide SCSI interface in older models
SCSI cable
GP5-839
GP5-840
X
GP5-841
O
O
O
O
O
O
O
O
O
O
O
O
O
Successor of GP5-838
Hard disk cabinet
GP5MS622A
GP5-HD9G3
GP5-HDH96
GP5-HD8G1
GP5-HDH83
GP5-185
Successor of GP5MS621A
Please refer to Figure2
Please refer to Figure2
Please refer to Figure2
Please refer to Figure2
Successor of GP5-182/184
Successor of GP5MS621A
Please refer to Figure2
Please refer to Figure2
Successor of GP5-182/184
Successor of GP5-125/GP5-126
C800series Hard disk drive-9GB
Hard disk drive-9GB
Hard disk drive-18GB
Hard disk drive-18GB
LAN card
Hard disk cabinet
G800 series Hard disk drive-9GB
Hard disk drive-18GB
LAN card
GP5S622A
GP5-HDH96
GP5-HDH83
GP5-185
SCSI card
GP5-127
RAID card
GP5-146
Successor of GP5-145 with Windows NT only
For Netware/Intranetware, please use GP5-145
Hard disk cabinet
DLT unit
GP5MS622A
GP5-DL351
GP5-HDH97
GP5-HDH98
GP5-HDH84
GP5-HDH85
GP5-HDH61
GP5-185
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Successor of GP5MS621A
Two PSU (one is standard) are required when mounting GP5-DL351
Please refer to Figure2
L800 series Hard disk drive-9GB
Hard disk drive-9GB
Hard disk drive-18GB
Hard disk drive-18GB
Hard disk drive-36GB
LAN card
Please refer to Figure2
Please refer to Figure2
Please refer to Figure2
New
Successor of GP5-182/184
Successor of GP5-125/GP5-126
SCSI card
GP5-127
RAID card
GP5-146
Hard disk cabinet
RCI card
GP5MS622A
GP5-RC101
GP5-HDH97
GP5-HDH98
GP5-HDH84
GP5-HDH85
GP5-HDH61
GP5-185
Successor of GP5MS621A
New for Pedestal type, Standard equipment for Rackmount type
Please refer to Figure2
M800 series Hard disk drive-9GB
Hard disk drive-9GB
Hard disk drive-18GB
Hard disk drive-18GB
Hard disk drive-36GB
LAN card
Please refer to Figure2
Please refer to Figure2
Please refer to Figure2
New
Successor of GP5-182/184
Successor of GP5-125/GP5-126
SCSI card
GP5-127
RAID card
GP5-146
Hard disk cabinet
GP5MS622A
Successor of GP5MS621A
II. Ultra wide or Ultra2 Wide on C300 series
The new C300 series (GP5C377, GP5C378, GP5C379) supports Ultra2 Wide SCSI.
To use new C300 series as an Ultra2 Wide system, Ultra2 Wide HDD, Ultra2 Wide SCSI (RAID) card and Ultra2
Wide SCSI cable are required
Previous models (GP5C300 to GP5C375 - Released Jul,1999) cannot support Ultra2 Wide even if Ultra2 Wide
SCSI HDD, card & cable are mounted.
For connection details, please refer to "Available SCSI cards for C300i"
7
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Available SCSI card for C300i
(1) GP5C377/378/379 (Ultra2 Wide)
Connected device
SCSI card
Channel
Cable
Remarks
Internal HDD
GP5-126
GP5-126
GP5-127
Internal Channel
(68pin)
GP5-839
GP5-841
GP5-840
Up to four HDDs
Internal Backup device
Internal Channel
(50pin)
Internal Channel
(68pin)
When using EIDE HDD or
RAID, GP5-127 must be
used instead of GP5-126*
Hard disk cabinet
GP5-127
External Channel
(68pin)
GP5MU823A
*SCSI card (GP5-126) is required for connecting SCSI HDD
(2) GP5C300-375 (Ultra wide)
Connected device
Internal HDD (SCSI)
SCSI card
GP5-125
Channel
Internal Channel
(68pin)
Cable
GP5-837
Remarks
Up to four HDDs
Internal Backup device
Hard disk cabinet
GP5-125
GP5-125
Internal Channel
(50pin)
GP5-841
External Channel
(68pin)
GP5MU823A
# of SCSI Channel of each SCSI card is as below:
SCSI card
GP5-125
GP5-126
GP5-127
Internal
External
1(68pin)
1(68pin)
1(68pin)
2(68pin+50pin)
2(68pin+50pin)
1(68pin)
2.Internal HDD
The HDD line-up has changed. The figure below indicates each product and its successor.
Current and successor HDDs of the same size can be used together in the same physical pack.
Figure 2
Main unit
Product
Current HDD Succesor HDD
Remarks
Product ID
Product ID
C300 series Hard disk drive-4GB
Hard disk drive-9GB
GP5-HD4G5
GP5-HD4G51
GP5-HD4G5B For mounting in 5" bay
GP5-HD9G3
GP5-HD9G2
GP5-HD9G3B For mounting in 5" bay
GP5-HD4G51
C800 series Hard disk drive-4GB
Hard disk drive-4GB
Hard disk drive-9GB
Hard disk drive-9GB
G800 series Hard disk drive-4GB
Hard disk drive-4GB
Hard disk drive-9GB
Hard disk drive-9GB
L800 series Hard disk drive-4GB
M800 series Hard disk drive-9GB
Hard disk drive-9GB
GP5-HD4G5
GP5-HDH44
GP5-HD9G3
GP5-HDH92
GP5-HDH44
GP5-HDH46
GP5-HDH92
GP5-HDH95
GP5-HDH45
GP5-HDH93
GP5-HDH94
GP5-HDH81
GP5-HDH82
GP5-HDH461
GP5-HD9G3
GP5-HDH96
GP5-HDH461
GP5-HDH461
GP5-HDH96
GP5-HDH96
GP5-HDH451
GP5-HDH97
GP5-HDH98
GP5-HDH84
GP5-HDH85
Can be used with GP5-HDH46
Can be used with GP5-HDH95
Can be used with GP5-HDH46
Can be used with GP5-HDH95
Hard disk drive-18GB
Hard disk drive-18GB
Successor products of the same size can be used as additional HDD in a physical pack that contains current/previous products.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver HS900
teamserver HS900 series
CPU: Pentium®lll Xeon™ (550MHz) x 2(~8) , Cache (L1+L2) : 32KB+2MB/1MB, Internal Hard disk bay:(Hot-plug) 2bays,
2 x Ultra2 Wide SCSI Onboard, 2ch RAID Card, CD-ROM, LAN Card (Std.), Redundant Power Supply (Std.)/FAN (Std.),
Intel LANDesk® Server Manager/Servervisor, ServerWizard
GP5T9A32R
GP5T9A22R
[Rackmount Type]
2CPU, Memory:1GB(ECC), HDD:Option
[Rackmount Type]
2CPU, Memory:1GB(ECC), HDD:Option
[Rackmount type]
CPU
Standard : 2CPUs
Max : 8CPUs
CPU Field Upgrade Kit (Pentium®III Xeon
GP5-FG203T
™
-550MHz (2MB) ●1)
-550MHz (1MB) ●1)
q
CPU Field Upgrade Kit (Pentium®III Xeon
™
GP5-FG202T
Memory
Max. memory: 32GB
Additional Memory - 256MB (128MB-DIMM●2)
GP5-RM25J
w
Standard memory : 1GB (128MB-DIMM●8)
Additional Memory - 512MB (256MB-DIMM●2)
GP5-RM51J
Additiond Memory Board
GP5-RB201
w
Additional Memory - 1024MB (512MB-DIMM●2)
GP5-RM1J
Internal Hard Disk
Up to two HDDs can be mounted in the main unit
Additional Memory - 2048MB (1024MB-DIMM●2)
GP5-RM2J
Max : 2
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
SCSI on board
e
y
GP5-HDH98T
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85T
RAID Card (GP5-146 : std.)
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61T
Connect with Storage System
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
Max : 8
GP5-HDH98
y
Max : 1
SCSI Card (Ultra2 Wide)
SCSI Cable(3m)
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
Storage System
GP5UR1DC4
GP5-127
GP5MU823A
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
SCSI Cable(5m)
GP5S-833
GP5-HDH61
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
SCSI Cable(10m)
GP5S-834
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
Redundant Power Supply Unit GP5U R1PU1
9
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH98
y
RAID Card
*
Storage System
GP5UR1DC4
SCSI Cable
GP5S-832
(Cache : 32MB
Ultra2 Wide SCSI)
GP5-144
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61
SCSI Cable
GP5S-835
RAID Card
*
(Cache : 16MB
Ultra2 Wide SCSI)
GP5-146
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
SCSI Cable
GP5S-836
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
Up to four
Backup Cabinet
GP5UR1BC1
(Please refer to P.18)
Back up devices
o
y
SCSI Cable
GP5S-832
Redundant Power
Supply Unit
GP5UPU151
Server Monitor Module
GP5USM103
10
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver M800 series
teamserver M800 series
CPU: Pentium®lll Xeon™ (550MHz) x 1(~4) , Cache (L1+L2) : 32KB+2MB/1MB, Internal Hard disk bay:(Hot-plug) 14bays (Pedestal)/6bays(Rackmount)
CD-ROM, LAN Card (Std.), Redundant Power Supply (Opt.)/FAN (Std.), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
M890ie GP5M895AL
GP5M895BL
[1CPU/Pedestal Type]
1CPU, Memory:256MB(ECC), HDD:Option
[1CPU/Rackmount Type]
1CPU, Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU, Memory:256MB(ECC), HDD:Option
[1CPU/Rackmount Type]
[Pedestal type]
M880ie GP5M885AL
GP5M885BL
1CPU, Memory:256MB(ECC), HDD:Option
[Rackmount type]
CPU
CPU Field Upgrade Kit (Pentium®III Xeon™
-550MHz (2MB) ●1)
GP5-FG203
Max : 4CPUs
q
w
CPU Field Upgrade Kit (Pentium®III Xeon™
-550MHz (1MB) ●1)
GP5-FG202
Memory
Max : 8GB
Additional Memory- 256MB (64MB-DIMM●4)
GP5-RM25G
Standard memory : 256MB (64MB-DIMM●4)
Additional Memory - 512MB (128MB-DIMM●4)
GP5-RM51G
AdditionalMemory- 1024MB (256MB-DIMM●4)
GP5-RM1G
Internal Hard Disk
●Pedestal Type : Up to 14 (6 in standard, 8 in optional Storage System)
disks can be installed.
Rackmount Type : Up to 6 disks can be installed in a rackmount
type node.
(1)Disk Addition / Duplexing
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
y
SCSI Card (Ultra2 Wide)
GP5-127
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH98
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61
For pedestal type
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
y
SCSI Card (Ultra2 Wide)
GP5-127
SCSI Cable(3m)
GP5MU823A
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
Storage System
GP5UR1DC4
GP5-HDH98
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61
Redundant Power Supply Unit
GP5UR1PU1
11
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
y
RAID Card
*
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH98
(Cache : 32MB
Ultra2 Wide SCSI)
GP5-144
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
RAID Card
*
(Cache : 16MB
Ultra2 Wide SCSI)
GP5-146
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61
For pedestal type
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
SCSI Cable
GP5S-832
Storage System
GP5UR1DC4
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH98
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
y
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
Server Monitor Module
GP5USM102
GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61
Redundant Power Supply Unit
GP5UR1PU1
Redundant Power Supply Unit
GP5UPU141
i
NOTE ; Please reter to P.20 for rackmounting instructions.
For mounting restrictions, please see P.4
*
12
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver L800 series
teamserver L800 series
CPU: Pentium®lll Xeon™ (550MHz) x 1(~4) , Cache (L1+L2) : 32KB+2MB/1MB/512KB, On board SCSI,
Internal Hard disk bay: 8bays (Hot-plug), CD-ROM, LAN Card (Std.), Servervisor/Intel LANDesk® Server Manager, ServerWizard
L890ie
L880ie
L870ie
GP5L895L
GP5L895LR
GP5L885L
GP5L885LR
GP5L875L
GP5L875LR
[1CPU/Pedestal Type]
1CPU(Cache:2MB), Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Cache:2MB), Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Cache:1MB), Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Cache:1MB), Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Cache:512KB), Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
[Pedestal type]
[Rackmount type]
1CPU(Cache:512KB), Memory:256MB(ECC), HDD:Option
CPU
Max : 4CPSs
CPU Field Upgrade Kit (Pentium®III Xeon™
-550MHz (2MB) ●1)
GP5-FG203 (for L890ie)
q
w
e
CPU Field Upgrade Kit (Pentium®III Xeon™
-550MHz (1MB) ●1)
GP5-FG202 (for L880ie)
CPU Field Upgrade Kit (Pentium®III Xeon™
-550MHz (512KB) ●1)
GP5-FG201 (for L870ie)
Memory
Max : 4GB
Additional Memory - 128MB (32MB-DIMM●4)
GP5-RM12G
Standard memory : 256MB (64MB-DIMM●4)
Additional Memory - 256MB (64MB-DIMM●4)
GP5-RM25G
Additional Memory - 512MB (128MB-DIMM●4)
GP5-RM51G
Additional Memory - 1024MB (256MB-DIMM●4)
GP5-RM1G
Internal Hard Disk
(1)Disk Addition / Duplexing
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
●
Up to 8 disks can be installed
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH98
Bay 1~6 : 9.1GB/18.2GB/36.4GB
Bay 7~8 : 9.1GB/18.2GB
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61
Internal Disk Array
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH97
RAID Card (Cache : 32MB,
Ultra2 Wide SCSI)
GP5-144
*
*
y
y
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH98
RAID Card (Cache : 16MB,
Ultra2 Wide SCSI)
GP5-146
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH84
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
RCI Card
GP5-RC101
(Standard Equipment
for Rackmount type)
o
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61
y
i
Server Monitor Module
GP5USM102
Redundant Power Supply Unit
GP5UPU131
For mounting restrictions, please see P.4
*
13
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver G800 series (Jan.1999)
teamserver G800 series
CPU: Pentium®lll (600MHz/550MHz/500MHz) x 1(~2) , Cache (L1+L2) : 32KB+512KB, On board SCSI,
CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 8bays (Hot-plug), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
G870ix
GP5G879L
[1CPU/Pedestal Type]
1CPU(Pentiumlll 600MHz), Memory:256MB(ECC), HDD:Option
[1CPU/Rackmount Type]
GP5G879LR
1CPU(Pentiumlll 600MHz), Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Pentiumlll 550MHz), Memory:256MB(ECC), HDD:Option
[1CPU/Rackmount Type]
G870ie GP5G878L
GP5G878LR
[Pedestal type]
1CPU(Pentiumlll 550MHz), Memory:256MB(ECC), HDD:Option
[1CPU/Pedestal Type]
G870i
GP5G877L
1CPU(Pentiumlll 500MHz), Memory:256MB(ECC), HDD:Option
[1CPU/Rackmount Type]
GP5G877LR
1CPU(Pentiumlll 500MHz), Memory:256MB(ECC), HDD:Option
[Rackmount type]
CPU
Max : 2CPUs
CPU Field Upgrade Kit (Pentium®III-600MHz (512KB) ●1)
GP5-FG10Y
(for G870ix)
q
CPU Field Upgrade Kit (Pentium®III-550MHz (512KB) ●1)
GP5-FG10V
(for G870ie)
CPU Field Upgrade Kit (Pentium®III-500MHz (512KB) ●1)
GP5-FG10N
(for G870i)
Memory
Max : 2GB
Additional Memory - 64MB (64MB SDRAM-DIMM●1)
w
GP5-RM64F
Standard memory : 256MB (256MB SDRAM-DIMM●1)
Additional Memory - 128MB (128MB SDRAM-DIMM●1)
GP5-RM12F
Additional Memory - 256MB (256MB SDRAM-DIMM●1)
GP5-RM25F
Additional Memory - 512MB (512MB SDRAM-DIMM●1)
GP5-RM51F
Internal Hard Disk
(1)Disk Addition / Duplexing
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH96
e
y
●Up to 8 disks in a teamserver
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH83
(2)Internal Disk Array
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH96
RAID Card (Cache : 4MB, Internal use only)
GP5U142
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm)
(Hot Plug)
GP5-HDH83
RAID Card (Cache : 32MB, Ultra2 Wide SCSI, BBU)
GP5-144
RAID Card (Cache : 16MB, Ultra2 Wide SCSI, BBU)
GP5-146
Server Monitor Module
GP5USM102
y
i
Redundant Power Supply Unit
GP5UPU131
NOTE : 2 PSUs are required if GP5-DL351 is
installed
Maximum 3PSUs can be instaled in G800i series.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver C800 series
teamserver C800 series
CPU: Pentium®lll (600MHz/550MHz/500/450MHz)x 1(~2) , Cache (L1+L2) : 32KB+512KB, On board SCSI,
CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 4bays (3xHot-plug), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
C870ix
C870ie
C870i
GP5C876
GP5C876R
GP5C875
GP5C875R
GP5C871
GP5C871R
GP5C855
GP5C855R
[1CPU/Pedestal Type]
1CPU(Pentiumlll 600MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Rackmount Type]
1CPU(Pentiumlll 600MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Pentiumlll 550MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Rackmount Type]
1CPU(Pentiumlll 550MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Pentiumlll 500MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Rackmount Type]
1CPU(Pentiumlll 500MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Pentiumlll 450MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Rackmount Type]
[Pedestal type]
C850ie
[Rackmount type]
1CPU(Pentiumlll 450MHz), Memory:128MB(ECC), HDD:Option
CPU
CPU Field Upgrade Kit (Pentium®III-600MHz (512KB) ●1)
GP5-FG10Y
(for C870ix)
Max : 2CPUs
q
CPU Field Upgrade Kit (Pentium®III-550MHz (512KB) ●1)
GP5-FG10V
(for C870ie)
CPU Field Upgrade Kit (Pentium®III-500MHz (512KB) ●1)
GP5-FG10N
(for C870i)
CPU Field Upgrade Kit (Pentium®III-450MHz (512KB) ●1)
GP5-FG10W
(for C850ie)
Memory
Max : 1GB
Additional Memory - 64MB (64MB SDRAM-DIMM●1)
GP5-RM64F
w
Standard memory : 128MB (128MB SDRAM-DIMM●1)
Additional Memory - 128MB (128MB SDRAM-DIMM●1)
GP5-RM12F
Additional Memory - 256MB (256MB SDRAM-DIMM●1)
GP5-RM25F
Internal Hard Disk
Total 4 disks(3Hot Plug and 1non-Hot Plug) can be installed.
Hard Disk Drive - 9GB (Ultra Wide.7,200rpm)(Hot Plug)
GP5-HDH96
(1)Disk Addition to Hot Plug bays (Max . 3 disks)
e
y
Hard Disk Drive - 18GB (Ultra Wide.7,200rpm)(Hot Plug)
GP5-HDH83
(2)Internal Disk Array(Maximum 3Hot Plug disks can be installed)
Hard Disk Drive - 9GB (Ultra Wide.7,200rpm)
(Hot Plug)
GP5-HDH96
RAID Card (Cache : 16MB)
GP5U141
GP5-831
SCSI Cable (Intl.)
Hard Disk Drive - 18GB (Ultra Wide.7,200rpm)
(Hot Plug)
RAID Card (Cache : 8MB Internal Hard disk only)
GP5-143
GP5-HDH83
(3)Disk Addition to a non-Hot Plug bay
only one disk can be installed
Hard Disk Drive - 9GB (7,200rpm) (non-Hot Plug)
GP5-HD9G3
e
y
Hard Disk Drive - 18GB (7,200rpm) (non-Hot Plug)
GP5-HD8G1
Server Monitor Module
GP5USM102
15
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver C300 series
teamserver C300 series
CPU: Pentium®lll (600MHz/550MHz/500MHz)x 1, Cache (L1+L2) : 32KB+512KB, CD-ROM, On board LAN (Std.)
Internal Hard disk bay: 4bays (use one 5" bay : non-hot-plug), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
C370ix
C370ie
C370i
GP5C379
GP5C378
GP5C377
[1CPU/Pedestal Type]
1CPU(Pentiumlll 600MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Pentiumlll 550MHz), Memory:128MB(ECC), HDD:Option
[1CPU/Pedestal Type]
1CPU(Pentiumlll 500MHz), Memory:128MB(ECC), HDD:Option
Memory
Max : 768MB
Additional Memory-64MB (64MB SDRAM-DIMM ●1)
GP5-RM64H
w
Standard memory : 128MB(128MB-DIMM●1)
Additional Memory-128MB (128MB SDRAM-DIMM ●1)
GP5-RM12H
Additional Memory-256MB (256MB SDRAM-DIMM ●1)
GP5-RM25H
Max : 4disks
Internal Hard Disk
(1)Disk Addition
(EIDE Disk)
Max : 2
Max : 4
Hard Disk Drive-13GB (EIDE) (5400rpm)
GP5-HD3E1(mounted in 3.5" bay)
e
y
When the boot disk is SCSI, IDE disks can not be installed.
(SCSI Disk)
Hard Disk Drive-9GB (Ultra2 Wide. 7200rpm) (non-Hot plug)
GP5-HD9G3 (mounted in HDD bay, MAX:3)
GP5-HD9G3B (mounted in 5" bay)
SCSI Card
GP5-126
SCSI Cable
GP5-839
Hard Disk Drive-18GB (Ultra2 Wide. 7200rpm) (non-Hot plug)
GP5-HD8G1 (mounted in HDD bay MAX:3)
GP5-HD8G1B (mounted in 5" bay)
●GP5-126 Can be used to connect 5 inch backup devices.
(2) Internal Disk Array
Hard Disk Drive-9GB (Ultra2 Wide. 7200rpm) (non-Hot plug)
GP5-HD9G3 (mounted in HDD bay MAX:3)
GP5-HD9G3B (mounted in 5" bay)
y
y
RAID Card (Cache : 8MB, For internal HDD only)
GP5-143
SCSI Cable
GP5-839
Hard Disk Drive-18GB (Ultra2 Wide. 7200rpm) (non-Hot plug)
GP5-HD8G1 (mounted in HDD bay MAX:3)
GP5-HD8G1B (mounted in 5" bay)
Server Monitor Module
GP5USM102
16
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver C350ie
teamserver C350ie
CPU: Pentium®lll (450MHz) x 1, Cache (L1+L2) : 32KB+512KB, CD-ROM, LAN Card (Std.)
Internal Hard disk bay: 4bays (non-hot-plug), Servervisor, Intel LANDesk® Server Manager, System Walker, ServerWizard
C350ie
GP5C355
[1CPU/Pedestal Type]
1CPU(Pentiumlll 450MHz), Memory:64MB(ECC), HDD:Option
Memory
Max : 768MB
Additional Memory-64MB (64MB SDRAM-DIMM ●1)
GP5-RM64H
w
Standard memory : 64MB-DIMM●1
Additional Memory-128MB (128MB SDRAM-DIMM ●1)
GP5-RM12H
Additional Memory-256MB (256MB SDRAM-DIMM ●1)
GP5-RM25H
Max : 4disks
Internal Hard Disk
(1)Disk Addition
(EIDE Disk)
Max : 2
Hard Disk Drive-13GB (EIDE) (5400rpm)
GP5-HD3E1(mounted in 3.5" bay)
e
y
(SCSI Disk)
Max : 4
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug)
GP5-HD9G2
SCSI Card
GP5-125
SCSI Cable
GP5-837
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug)
GP5-HD9G3 (mounted in HDD bay, MAX 3)
GP5-HD9G3B (mounted in 5" bay)
Hard Disk Drive-18GB (Ultra Wide. 7200rpm) (non-Hot plug)
GP5-HD8G1 (mounted in HDD bay, MAX 3)
GP5-HD8G1B (mounted in 5" bay)
(2) Internal Disk Array
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug)
GP5-HD9G2
y
RAID Card (Cache : 8MB, For internal HDD only)
GP5-143
SCSI Cable
GP5-837
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug)
GP5-HD9G3 (mounted in HDD bay, MAX 3)
GP5-HD9G3B (mounted in 5" bay)
Hard Disk Drive-18GB (Ultra Wide. 7200rpm) (non-Hot plug)
GP5-HD8G1 (mounted in HDD bay, MAX 3)
GP5-HD8G1B (mounted in 5" bay)
Server Monitor Module
GP5USM102
y
Network Cards
teamserver
M800i G800i
L800i C800i
series series
HS900
series
C300i
series
LAN Card
y
y
y
y
y
y
GP5-183
LAN Card
GP5-185
y
17
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver Internal Devices
HS900
Up to four Tape units can be mounted
DLT unit (Occupied two 5" bay slots)
GP5-DL351
Backup Cabinet
GP5UR1BC1
o
SCSI Cable
GP5S-832
Tape unit
GP5-ML301
DLT unit (Occupied two 5" bay slots)
GP5UDL201
DAT unit
GP5UDT301
Tape unit
GP5USL501
Redundant Power Supply Unit
GP5UPU151
M800i
L800i
series
DLT unit (Occupied two 5" bay slots)
GP5-DL351
y
SCSI Card
GP5-127
Tape unit
GP5-ML301
DLT unit (Occupied two 5" bay slots)
GP5UDL201
r
DAT unit
GP5UDT301
Tape unit
GP5USL501
Tape unit
GP5-NS201
G800i
C800i
series
DLT unit *(Occupied two 5" bay slots)
GP5-DL351
Only G800i
y
Only G800i
SCSI Card
GP5-127
Tape unit
GP5-ML301
y
Only C800i
SCSI Card
GP5-125
DLT unit (Occupied two 5" bay slots)
GP5UDL201
r
Only G800i
DAT unit
GP5UDT301
r
*NOTE : 2 PSUs are required as standard if GP5-
DL351 is installed
Tape unit
GP5USL501
Maximum 3PSUs can be instaled in G800i series.
Tape unit
GP5-NS201
C300series
GP5C377
GP5C378
GP5C379
GP5C355
DAT unit
GP5UDT301
y
SCSI Cable
GP5-841
SCSI Card
GP5-126
Tape unit
GP5USL501
SCSI Card
GP5-127
Tape unit
GP5-NS201
SCSI Cable
GP5-840
y
SCSI Card
GP5-125
SCSI Cable
GP5-841
18
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver External Devices
(Pedestal only)
L800
G800
Hard disk cabinet
M800
series
C300
series
C800
series
Disk addition
Disk array
SCSI card
GP5-125
SCSI cable
GP5MU823A
y
C800 C350ie
only only
RAID card(cache:16MB)
GP5U141
SCSI cable
GP5MU829A
y
G/C800
only
y
GP5U141 can be used for Hard disk cabinet only when
GP5U142 is used to connect internal hard disk array.
Disk addition
Hard disk cabinet
GP5MS622A
SCSI card
GP5-127
SCSI cable
GP5MU823A
y
y
y
L/G800 except
only C350ie
y
Disk array
Disk array
RAID card(cache:32MB)
GP5-144
SCSI cable
GP5S-832
y
L/G800
only
RAID card(cache:16MB)
GP5-146
SCSI cable
GP5S-832
y
y
L/G800
only
Configuration of the inside Hard disk cabinet
Hard Disk Drive-9GB
(7,200rpm)
Hard Disk Drive-18GB
GP5-HDH97
(10,000rpm)
GP5-HDH85
Hard Disk Drive-9GB
(10,000rpm)
GP5-HDH98
Hard Disk Drive-36GB
(10,000rpm)
GP5-HDH61
Hard Disk Drive-18GB
(7,200rpm)
GP5-HDH84
Power Supply Unit
GP5URIPU1
19
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
teamserver Rackmount
40U Rack
GP5-R1RC4
40U Rack & Rack Coupling kit
GP5-R1RC5
●A maximum of two servers can be installed in a, 40U Rack system.
●The Rack Coupling kit is used for connecting two Racks together.
24U Rack
GP5-R2RC1
24U Rack & Rack Coupling kit
GP5-R2RC2
Component Shelf GP5-R1TB4
Keyboard/Monitor Shelf Kit GP5-R1TB5(for GP5-
R2RC1/GP5-R1RC4)
teamserver CPU nodes for Rackmount
Key board/Monitor
Enhanced Switch
GP5-SB101
Enhanced keyboard
GP5-R1KB2
Keyboard/Monitor Extention Cables
GP5-411
– Each GP5-411 is reguired for each CPU node.
– One GP5-SB101 is used for max.
4 CPU nodes.
HS900
M800
Series
L800
G800
C800
Series
Storage System
GP5UR1DC4
y
C800
Only
SCSI Cable
GP5MU823A
SCSI Card
GP5-125
y
C800
Only
RAID Card●
GP5U141
SCSI Cable
GP5MU829A
y
y
y
y
y
y
y
L/G 800
Only
SCSI Card
GP5-127
SCSI Cable
GP5MU823A/GP5S-833/834
y
L/G 800
Only
RAID Card
GP5-144
SCSI Cable
GP5S-832/835/836
y
L/G 800
Only
RAID Card
GP5-146
SCSI Cable
GP5S-832/835/836
●GP5U141 can be used for Hard disk cabinet only when GP5U142 is used to connect internal hard disk array.
[Inside of Storage System]
Hard Disk Drive-9GB(7,200rpm)
GP5-HDH97
Hard Disk Drive-18GB(10,000rpm)
GP5-HDH85
Hard Disk Drive-9GB(10,000rpm)
GP5-HDH98
Hard Disk Drive-36GB(10,000rpm)
GP5-HDH61
Hard Disk Drive-18GB(7,200rpm)
GP5-HDH84
Redundant Power Supply Unit
GP5UR1PU1
NOTE : A maximum of eight Hard Disk Drives can be installed in a Storage System.
In a RAID configuration, a physical pack must be comprised of the same
type of Hard disks.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
teamserver Hardware
Product
Product ID
GP5T9A32R
Remarks
teamserver HS900
(Rackmount)
Pentium lll Xeon 550MHz with 2MB Cache (x2, up to 8CPUs) , 1GB (128MB SDRAM-DIMM x8) SDRAM-DIMM with ECC,
( 32GB maximum ) 32xCD-ROM, FDD, 2x Ultra2 Wide Onboard SCSI and 2ch LVD array controller card, 100Base-
TX/10Base-T LAN Card 2Internal HDD bays (Ultra2wide SCSI/Hot plug), 64bit(66MHz)Hot-plug PCIx4, 64bit(33MHz)Hot-
plug PCIx6, Wakeup on LAN Hot plug-Redundant PSU/Fan, Servervisor/LANDesk Server Manager, ServerWizard
* Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
(End Nov 1999)
teamserver HS900
(Rackmount)
GP5T9A22R
Pentium lll Xeon 550MHz with 1MB Cache (x2, up to 8CPUs) , 1GB (128MB SDRAM-DIMM x8) SDRAM-DIMM with ECC,
( 32GB maximum ) 32xCD-ROM, FDD, 2x Ultra2 Wide Onboard SCSI and 2ch LVD array controller card, 100Base-
TX/10Base-T LAN Card 2Internal HDD bays (Ultra2wide SCSI/Hot plug), 64bit(66MHz)Hot-plug PCIx4, 64bit(33MHz)Hot-
plug PCIx6, Wakeup on LAN Hot plug-Redundant PSU/Fan, Servervisor/LANDesk Server Manager, ServerWizard
* Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
(End Nov 1999)
teamserver M890ie
(End Nov 1999)
GP5M895AL
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum )
32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card
6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5,
ISA/PCI32bitx1,
Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
* Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
teamserver M890ie
(Rackmount)
GP5M895BL
GP5M885AL
GP5M885BL
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum )
32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card
6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5,
ISA/PCI32bitx1,
(End Nov 1999)
Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
* Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
teamserver M880ie
(End Nov 1999)
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum )
32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card
6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5,
ISA/PCI32bitx1,
Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
* Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
teamserver M880ie
(Rackmount)
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum )
32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card
6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5,
ISA/PCI32bitx1,
(End Nov 1999)
Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
* Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
teamserver L890ie
(Mid Nov 1999)
GP5L895L
GP5L895LR
GP5L885L
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum )
24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN
Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
teamserver L890ie
(Rackmount)
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum )
24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN
(Mid Nov 1999)
Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
teamserver L880ie
(Mid Nov 1999)
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum )
24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN
Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
21
Download from Www.Somanuals.com. All Manuals Search And Download.
teamserver Hardware
Product
Product ID
GP5L885LR
Remarks
teamserver L880ie
(Rackmount)
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum )
24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN
Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
(Mid Nov 1999)
teamserver L870ie
(Mid Nov 1999)
GP5L875L
GP5L875LR
GP5G879L
GP5G879LR
GP5G878L
GP5G878LR
GP5G877L
GP5G877LR
GP5C876
Pentium lll Xeon 550MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum )
24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN
Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
teamserver L870ie
(Rackmount)
Pentium lll Xeon 550MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum )
24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN
(Mid Nov 1999)
Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
teamserver G870ix
(Mid Nov 1999)
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum )
32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx4, ISA/PCIx1, ISAx1, Hot plug PSU,Hot plug Fan, Wakeup on LAN,
Servervisor/LANDesk Server Manager, ServerWizard
teamserver G870ix
(Rackmount)
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum )
32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC4x4, PCIx4, ISA/PCIx1,
ISAx1 Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
(Mid Nov 1999)
teamserver G870ie
(Mid Nov 1999)
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum )
32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx4, ISA/PCIx1, ISAx1, Hot plug PSU,Hot plug Fan, Wakeup on LAN,
Servervisor/LANDesk Server Manager, ServerWizard
teamserver G870ie
(Rackmount)
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum )
32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC4x4, PCIx4, ISA/PCIx1,
ISAx1 Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
(Mid Nov 1999)
teamserver G870i
(Mid Nov 1999)
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum )
32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx4, ISA/PCIx1, ISAx1, Hot plug PSU,Hot plug Fan, Wakeup on LAN,
Servervisor/LANDesk Server Manager, ServerWizard
teamserver G870i
(Rackmount)
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum )
32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC4x4, PCIx4, ISA/PCIx1,
ISAx1 Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
(Mid Nov 1999)
teamserver C870ix
(Mid Nov 1999)
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C870ix
(Rackmount)
GP5C876R
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2,
Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
(Mid Nov 1999)
22
Download from Www.Somanuals.com. All Manuals Search And Download.
teamserver Hardware
Product
Product ID
GP5C875
Remarks
teamserver C870ie
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C870ie
(Rackmount)
GP5C875R
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2,
Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C870i
GP5C871
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C870i
(Rackmount)
GP5C871R
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2,
Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C850ie
GP5C855
Pentium lll 450MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C850ie
(Rackmount)
GP5C855R
Pentium lll 450MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum )
32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN
4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2,
Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C370ix
(Mid Nov 1999)
GP5C379
GP5C378
GP5C377
GP5C355
Pentium lll 600MHz with 512KB Cache (x1),128MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum)
32xCD-ROM, FDD, 100Base-TX/10Base-T
PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra2 Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C370ie
(Mid Nov 1999)
Pentium lll 550MHz with 512KB Cache (x1),128MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum)
32xCD-ROM, FDD, 100Base-TX/10Base-T
PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra2 Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C370i
(Mid Nov 1999)
Pentium lll 500MHz with 512KB Cache (x1),128MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum)
32xCD-ROM, FDD, 100Base-TX/10Base-T
PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra2 Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
teamserver C350ie
Pentium lll 450MHz with 512KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum)
32xCD-ROM, FDD, 100Base-TX/10Base-T
PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN
Servervisor/LANDesk Server Manager, ServerWizard
23
Download from Www.Somanuals.com. All Manuals Search And Download.
teamserver Hardware
HS900 M800i
L800i
G800i
C800i
C300i
Product ID
Product
Remarks
(Overseas inc.Korea)
●
●
●
●
CPU Field Upgrade Kit GP5-FG203T
CPU Field Upgrade Kit GP5-FG202T
CPU Field Upgrade Kit GP5-FG203
CPU Field Upgrade Kit GP5-FG202
CPU Field Upgrade Kit GP5-FG201
CPU Field Upgrade Kit GP5-FG10Y
CPU Field Upgrade Kit GP5-FG10V
CPU Field Upgrade Kit GP5-FG10N
CPU Field Upgrade Kit GP5-FG10W
P-lll Xeon(550MHz)/32KB+2MBcachex1,Placed on motherboard Includes one
CPU, For HS900
P-lll Xeon(550MHz)/32KB+1MBcachex1,Placed on motherboard Includes one
CPU, For HS900
●
P-lll Xeon(550MHz)/32KB+2MBcachex1,Placed on motherboard Includes one
CPU and dedicated power supply module (VRM)
●
P-lll Xeon(550MHz)/32KB+1MBcachex1,Placed on motherboard Includes one
CPU and a dedicated power supply module (VRM)
●
P-lll Xeon(550MHz)/32KB+512KBcachex1,Placed on motherboard Includes one
CPU and a dedicated power supply module (VRM)
●
●
P-lll(600MHz)/32KB+512KB, for G870ix/C870ix
Do not mix with other processor speed
●
●
P-lll(550MHz)/32KB+512KB, for G870ie/C870ie
Do not mix with other processor speed
●
●
P-lll(500MHz)/32KB+512KBx1, for G870i/C870i
Do not mix with other processor speed
●
P-lll(450MHz)/32KB+512KBx1, for G850ie/C850ie
Do not mix with other processor speed
● ●
● ●
● ●
● ●
● ●
Additional Memory 2GB GP5-RM2J
(End Feb 00)
SDRAM-DIMM 1024MBx2 (Registered 100MHz)
SDRAM-DIMM 512MBx2 (Registered 100MHz)
SDRAM-DIMM 256MBx2 (Registered 100MHz)
SDRAM-DIMM 128MBx2 (Registered 100MHz)
Additional memory board for mounting more than 16GB memory
EDO-DIMM(Buffered;50ns)256MBx4
Additional Memory 1GB GP5-RM1J
(End Jan 00)
Additional Memory 512MB
(End Jan 00)
GP5-RM51J
Additional Memory 256MB
GP5-RM25J
Additional Memory Board GP5-RB201
Additional Memory 1GB GP5-RM1G
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ●
Additional Memory 512MB
Additional Memory 256MB
Additional Memory 128MB
Additional Memory 512MB
Additional Memory 256MB
Additional Memory 128MB
Additional Memory 64MB
Additional Memory 256MB
Additional Memory 128MB
Additional Memory 64MB
GP5-RM51G
GP5-RM25G
GP5-RM12G
GP5-RM51F
GP5-RM25F
GP5-RM12F
GP5-RM64F
GP5-RM25H
GP5-RM12H
GP5-RM64H
EDO-DIMM(Buffered;50ns)128MBx4
EDO-DIMM(Buffered;50ns)64MBx4
EDO-DIMM(Buffered;50ns)32MBx4
● ● ●
SDRAM-DIMM 512MBx1 (Registered 100MHz)
SDRAM-DIMM 256MBx1 (Registered 100MHz)
SDRAM-DIMM 128MBx1 (Registered 100MHz)
SDRAM-DIMM 64MBx1 (Registered 100MHz)
Unbuffered SDRAM-DIMM 256MBx1
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
Unbuffered SDRAM-DIMM 128MBx1
Unbuffered SDRAM-DIMM 64MBx1
● ●
● ●
● ●
Hard Disk Drive-36GB GP5-HDH61T
Hard Disk Drive-18GB GP5-HDH85T
36.4GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for HS900
18.2GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for HS900
9.1GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for HS900
Hard Disk Drive-9GB
GP5-HDH98T
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
Hard Disk Drive-36GB GP5-HDH61
Hard Disk Drive-18GB GP5-HDH85
36.4GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi,
Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
18.2GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi,
Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
Hard Disk Drive-9GB
GP5-HDH98
9.1GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi,
Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
Hard Disk Drive-18GB GP5-HDH84
18.2GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi,
Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
Hard Disk Drive-9GB
GP5-HDH97
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi,
Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
24
Download from Www.Somanuals.com. All Manuals Search And Download.
teamserver Hardware
HS900 M800i
L800i
G800i
C800i
C300i
Product ID
Product
Remarks
(Overseas inc.Korea)
● ● ● ● ● ● ●
● ● ● ● ● ● ●
●
Hard Disk Drive-18GB GP5-HDH83
18.2GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, For G8xxi,C8xxi
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, For G8xxi, C8xxi
Hard Disk Drive-9GB
Hard Disk Drive-9GB
GP5-HDH96
GP5-HDH92
9.1GB,Ultra Wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, Additional disk for
GP5C800-875
●
●
Hard Disk Drive-4GB
Hard Disk Drive-4GB
GP5-HDH461
GP5-HDH44
4.3GB,Ultra2 Wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug Additional disk for
GP5C800-875/GP5G810-876L
4.3GB,Ultra Wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, Additonal disk for
GP5C800-875
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
Hard Disk Drive-18GB GP5-HD8G1
18.2GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for C8xxi(Mounted in
Non Hotplug bay), C3xxi(Mounted in Non Hotplug 3.5"Bay)
Hard Disk Drive-9GB
Hard Disk Drive-9GB
Hard Disk Drive-4GB
Hard Disk Drive-4GB
GP5-HD9G3
GP5-HD9G2
GP5-HD4G51
GP5-HD4G5
9.1GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for C8xxi(Mounted in
Non Hotplug bay), C3xxi(Mounted in Non Hotplug 3.5"Bay)
●
●
●
●
●
9.1GB,Ultra Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for
GP5C300-375/GP5C800-C875
4.3GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for
GP5C300-375/GP5C800-C875
●
4.3GB,Ultra Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for
GP5C300-375/GP5C800-C875
● ● ● ●
● ● ● ●
●
Hard Disk Drive-18GB GP5-HD8G1B
18.2GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for mounting in
5"bay of C3xxi
Hard Disk Drive-9GB
Hard Disk Drive-4GB
GP5-HD9G3B
GP5-HD4G5B
9.1GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for mounting in 5"bay
of C3xxi
4.3GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for
mounting in 5"bay of GP5C300-C375
● ● ● ●
Hard Disk Drive-13GB GP5-HD3E1
EIDE,5400rpm, 13GB, for C3xxi
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
DAT unit (DDS-3)
GP5UDT301
DDS-3 (12-24GB) Helical scan device back up 12GB (24GB average when
compressed) Effective transfer speed is 1MB/s (not compressed)When
connecting to C300i, SCSI Card (GP5-125,126/127) and SCSI Cable (GP5-
841/840) is required, Please order cartridge and cleaning cartridge separately.
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Tape unit (SLR5)
GP5USL501
SLR-5 (4-8GB) Single-channel linear recording system, 4GB (8GB average
when compressed) Effective transfer speed is 380KB/s (not compressed)Data
format: QIC-4GB, QIC-2GB, When connecting to C300i, SCSI Card (GP5-
125,126/127) and SCSI Cable (GP5-841/840) is required, Please order cartridge
and cleaning cartridge separately.
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
DLT unit
DLT unit
GP5UDL201
GP5-DL351
DLT4000SE narrow (20-40GB) Linear scan device back up 20GB (40GB
average when compressed) high-speed transfer up to 1.5MB/s (not
compressed)Shipped with one data cartridge and one cleaning cartridge.
DLT7000SE wide (35-70GB) Linear scan device back up 35GB (70GB average
when compressed) high-speed transfer up to 5.0MB/s (not compressed)Shipped
with one data cartridge, one cleaning cartridge and one internal SCSI Cable
(with terminal resistor added). Two 5"bays are required and occupied. When
mounting for G800i, additional PSU is required
● ● ● ● ● ● ● ● ● ● ● ● ● ●
Tape unit (MLR-3)
GP5-ML301
MLR-3 (20-40GB) Multi-channel linear recording system, 25GB (50GB average
when compressed) and high-speed transfer - up to 2.0MB/s (not
compressed)Data format: MLR3-25GB, SCSI Card is required to connect(Please
refer to PXX), Shipped with one data cartridge and one cleaning cartridge.
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
TRAVAN NS unit (NS-20) GP5-NS201
TRAVAN NS-20 (10-20GB) Linear scan device back up 10GB (20GB average
when compressed) and high-speed transfer - up to 1.0MB/s, Data format:QIC-
3220-MC, When connecting to C300i, SCSI Card (GP5-125,126/127) and SCSI
Cable (GP5-841/840) is required, Shipped with one data cartridge and one
cleaning cartridge.
● ●
Backup Cabinet
GP5UR1BC1
5" bay node for Rackmount (3U) Up to four Tape units can be mounted,
GP5UDL351/GP5-DL201/GP5UDT301/GP5USL501/GP5-ML301/GP5-NS201
are available, Redundant PSU (Opt.), SCSI Cable (GP5U832, GP5S823) is
required
● ● ● ● ● ●
● ●
Redundant Power Supply Unit
Redundant Power Supply Unit
GP5UPU131
GP5UPU141
Redundant PSU (450W)
Redundant PSU (350W)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
teamserver Hardware
HS900 M800i
L800i
G800i
C800i
C300i
Product ID
Product
Remarks
(Overseas inc.Korea)
● ●
Redundant Power Supply Unit
Redundant Power Supply Unit
Rackmount Pattern
40U Rack
GP5UPU151
GP5UR1PU1
GP5RMP
Redundant PSU (300W), For Backup Cabinet (GP5UR1BC1)
Redundant PSU for GP5UR1DC4/GP5MS622A (350W)
Rackmount pattern instruction
● ● R/P R/PR/PR/PR/PR/PR/PR/PR/PR/PR/PR/P ● ● ● ●
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
● ● R
GP5-R1RC4
19'' 40U Locker , Front door,rear door,side panel,earthquake proof board , blank
panel is attached. Size(WxDxH)mm:600x900x2000 <Number of units required
for installation> C8xxi:6U, G8xxi:7U, L8xxi:7U, M8xxi/ic:10U GP5UR1DC4: 4U
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation
Keyboard) Component shelf: 5U CRT/KB switch: Mounted at side of CRT
(occupies same U as CRT)
● ● R
● ● R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
40U Rack&Rack Coupling Kit
GP5-R1RC5
GP5-R2RC1
19''40U Locker + connection metal fittings Front door,rear door,concatenation
frame,blank panel is attached.
24U Rack
19'' 24U Locker , Front door,rear door,side panel,earthquake proof board , blank
panel is attached. Size(WxDxH)mm:600x900x1200 <Number of units required
for installation> C8xxi:6U, G8xxi:7U, L8xxi:7U, M8xxi/ic:10U GP5UR1DC4: 4U
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation
Keyboard) Component shelf: 5U CRT/KB switch: Mounted at side of CRT
(occupies same U as CRT)
● ● R
R
R
R
R
R
R
R
R
R
R
R
24U Rack&Rack Coupling Kit
GP5-R2RC2
19''24U Locker + connection metal fittings Front door,rear door,concatenation
frame,blank panel is attached.
● ● R
● ● R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Component Shelf
GP5-R1TB4
GP5-R1TB5
Shelf to fit peripheral device into 40U Rack, Table size:400(W)x500(D)
Keyboard/Monitor Shelf Kit
For New Rack (as of Jul 1999: GP5-R2RC1/GP5-R1DC4) Used to store display
unit (CRT), a keyboard (KB), and a mouse on a rack.
● ● R
R
R
R
R
R
R
R
R
R
R
R
Keyboard/Monitor Enhanced Switch
GP5-SB101
Switch enables sharing of a set of CRT,keyboard,and mouse by two or more
servers (up to four servers).
● ● R
● ● R
● ● R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Keyboard/Monitor Extension Cables
Enhanced Keyboard
Storage System
GP5-411
CRT/KB cable , CRT cablex1,KB/Mouse cablex1 is attached
87Key keyboard for Rackmountable type
GP5-R1KB2
GP5UR1DC4
Hard Disk Node LVD/SE for Rack (4U) 8 Hot plug HDD Bays (up to 291.2GB:
36.4GBx8) Support Ultra2 Wide SCSI/Ultra Wide SCSI, Redundant FAN(Up to
two Std.)/PSU(A GP5UR1PU1is standard equipment, up to two)
P
P
P
P
P
P
P
P
P
P
P
P
● ● ● ●
Hard Disk Cabinet
SCSI Card
GP5MS622A
GP5-123
Hard Disk Cabinet LVD/SE for Pedestal 8 Hot plug HDD Bays (up to 291.2GB:
36.4GBx8) Support Ultra2 Wide SCSI/Ultra Wide SCSI, Redundant FAN(Up to
two Std.)/PSU(A GP5UR1PU1is standard equipment, up to two)
● ● ● ● ● ● ● ● ● ●
Ultrawide, differential-end, x1ch, SMART not supported, Up to 40MB/s of
syncronous transfer support Connector: half-pitch 68pin for external SCSI
device, half-pitch 50/68pin for internal SCSI device For connection with Disk
Array devices * SCSI cable is required.
● ● ● ●
●
SCSI Card
GP5-125
Ultrawide, SE, x1ch, SMART supported, Up to 40MB/s of syncronous transfer
support Connector: half-pitch 68pin for external SCSI device, half-pitch 50/68pin
for internal SCSI device. For connection with internal and external SCSI devices
*SCSI cable is required.
● ● ●
● ● ●
SCSI Card
SCSI Card
GP5-126
GP5-127
Ultra2 Wide, LVD, x1ch, SMART supported, Up to 80MB/s of syncronous
transfer support Connector: half-pitch 68pin and half-pitch 50/68pin. *SCSI cable
is required
● ● ● ● ● ● ● ● ● ●
Ultra2 Wide, LVD, x1ch, SMART supported, Up to 80MB/s of syncronous
transfer support Connector: half-pitch 68pin for external SCSI device, half-pitch
50/68pin for internal SCSI device. For connection with internal OR external SCSI
devices *SCSI cable is required
● ● ● ● ● ● ●
RAID Card
GP5U141
GP5U142
GP5-143
Raid card, Ultrawide SCSI, SE, x2ch, 16MB cache, RAID level 0,1,5 are
supported For internal/external array configuration *SCSI cable(for array
configuration use) is required
● ● ●
RAID Card
Raid card, Ultrawide SCSI, SE, x2ch, 4MB cache, RAID level 0,1,5 are
supported For internal array configuration *SCSI cable(for array configuration
use) is required
● ● ● ● ● ● ● ●
RAID Card
Raid card, Ultrawide SCSI, x2ch, 8MB cache, RAID level 0,1,5,6 are supported
For internal array configuration *SCSI cable(for array configuration use) is
required
●●P : Pedestal, R : Rack
26
Download from Www.Somanuals.com. All Manuals Search And Download.
teamserver Hardware
HS900 M800i
L800i
G800i
C800i
C300i
Product ID
Product
Remarks
(Overseas inc.Korea)
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
RAID Card
GP5-144
GP5-146
Raid card, Ultra2 Wide SCSI, LVD, x3ch, 32MB cache, Battery Backup, RAID
level 0,1,5,6 are supported For internal/external array configuration *SCSI
cable(for array configuration use) is required
RAID Card
Raid card, Ultra2 Wide SCSI, LVD, x2ch, 16MB cache, Battery Backup, RAID
level 0,1,5,6 are supported For internal/external array configuration *SCSI
cable(for array configuration use) is required
● ● ● ●
SCSI Cable
SCSI Cable
GP5U831
GP5-837
Connection internal devices (0.7m) for C8xxi
● ● ● ●
Ultra Wide SCSI cable(68pin), Internal SCSI HDD connection with GP5U141in
C3xxi
● ● ●
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
GP5-839
Ultra2 Wide SCSI cable (68pin), Internal SCSI HDD connection in GP5C377-379
Internal narrow SCSI cable for 5'' Bay (50pin) for GP5-127 in GP5C377-379
Internal narrow SCSI cable for 5'' Bay (50pin) for GP5-125/126 in C3xxi
For connection GP5-144/146 to GP5UR1DC4/GP5MS622A (3m)
● ● ●
GP5-840
● ● ● ●
GP5-841
● ● ● ● ● ● ● ● ● ●
GP5S-832
GP5S-833
GP5S-834
GP5S-835
GP5S-836
GP5MU823A
● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ●
For connection GP5-127 to GP5UR1DC4 (5m), Only for Rackmount
For connection GP5-127 to GP5UR1DC4(10m), Only for Rackmount
For connection GP5-144/146 to GP5UR1DC4(5m), Only for Rackmount
For connection GP5-144/146 to GP5UR1DC4(10m), Only for Rackmount
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5-125/127 to
GP5MS622A,GP5UR1DC4 (3.0m)
SCSI Cable
GP5MU829A
For connection between GP5U141 and GP5MS622A/GP5U141 to GP5UR1DC4
(2.0m)
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ●
SCSI Cable
GP5U832
GP5U833
GP5U834
GP5-311
GP5-312
GP5-313
SCSI Cable half68pin-Full50pin (1.0m)
SCSI Cable
SCSI Cable half68pin-half50pin (1.0m)
SCSI Cable
SCSI Cable half50pin-full50pin (1.0m)
Fibre Channel Cable
Fibre Channel Cable
Fibre Channel Cable
Fibre Channel Card (3m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-183)
Fibre Channel Card (5m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-183)
● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ●
Fibre Channel Card (15m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-
183)
● ● ● ● ● ● ● ● ● ●
Fibre Channel Card
GP5-FC101
High-transfer speed of up to 100MB/s, Long transfer distance of up to 500m,
PCI-bus, driver is included, Fibre Channel cable is required
● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
LAN Card (1000Base-SX) GP5-183
1000BASE-SX, PCI-bus, driver is included Fibre Channel cable is required :
GP5-311/2m, GP5-312/5m, GP5-313/15m
LAN Card
RCI Card
GP5-185
100BASE-TX/10BASE-T, PCI-bus, driver is included, Twisted pair cable
(category 5:100BASE-TX/category 3:10BASE-T) is required
Remote Console Interface Card, For Pedestal type of L800, Standard equipment
of L800series Rackmount
● ● ●
GP5-RC101
Server Monitor Module has its own CPU,LAN,and power supply (AC adapter:
option-procured locally). External Interface:10BASE-T RJ45 / RS232C D-sub
9pin, AC adapter:16V(DC) * Modem-only operation is impossible.
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Server Monitor Module GP5USM102
Server Monitor Module GP5USM103
Server Monitor Module has its own CPU,LAN,and power supply (AC adapter:
option-procured locally). External Interface:10BASE-T RJ45 / RS232C D-sub
9pin, AC adapter:16V(DC), For HS900 * Modem-only operation is impossible.
● ●
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications are subject to change without notice. For the latest detailed information, contact your local representative.
All brand names and product names are trademarks and registered trademarks of their respective holders.
C
1999 Fujitsu Limited. All rights reserved. Printed in Japan.
Six Edition November 1999
FUJITSU LIMITED
Business Development & Marketing Division
Marketing Group
Marunouchi Center Building
6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-8211, Japan
Phone: +81-3-3215-5255 Fax: +81-3-3215-5259
BK0065-6NS