| EPA   DOE   (D40 / D50 Only)   In s t a lla t io n   & Op e ra t io n Gu id e   DEHUMIDIFIER   MODELS   115 Vo lts • D30 • D40 • D50   Register Your Dehumidifier   Model information can be found on the name plate on the rear of   the unit behind the condensate bucket.   To register your dehumidifier, complete and mail the enclosed   only). For your future convenience, record the model information   here.   MODEL NUMBER   SERIAL NUMBER   PURCHASE DATE   920-137-00 (01/02)   Download from Www.Somanuals.com. All Manuals Search And Download.   Safety Precautions   Read all instruction before using.   I To prevent property damage or injury to the user or others, the following instructions myst be followed.   I Incorrect operation due to ignoring instructions will cause harm or damage; the seriousness is classified by the   following indications.   WARNING   CAUTION   This symbol indicates the possibility of death or serious injury.   This symbol indicates the possibility of injury or damage to properties only.   I Meanings of symbols used in this manual are as shown below.   Never do this.   Always do this.   WARNING   WARNING   Complete all grounding and   installation requirements as   described on page 5.   Disconnect power cord from   receptacle before servicing or   cleaning.   Do not use flammable fluids, solvents,   abrasive cleaners, or strong detergents   to clean the dehumidifier.   • It could cause electrical shock   • It could cause electrical shock   • It could cause fire or product   or fire.   or fire.   damage hazard.   N E R S C O A U G R I N L B e G R E   R n z en   e Do not plug the dehumidifier   in until the outside of unit is   completely dry.   Do not use the water collected   in the bucket for drinking   purposes.   Do not clean the dehumidifier   while it is plugged in.   • It could cause electrical shock   and personal injury hazard.   • It is not sanitary and could   cause illness or personal injury   hazard.   • It may cause electrical shock.   3 Download from Www.Somanuals.com. All Manuals Search And Download.   CAUTION   CAUTION   Be sure to block the wheels to   prevent unit from falling when   installed on a table or shelf.   Be sure to replace bucket   properly after emptying to   prevent water from collecting   on the floor.   Make sure the dehumidifier is   the correct size for the area   you want to dehumidify.   • It may damage the dehumidifier   or cause other damage or   injury.   Do not operate switches with   wet hands.   Install the dehumidifier   properly on a floor, table, or   shelf that is level and strong   enough to support it with a full   bucket of water.   Do not install dehumidifier in   an area where temperatures   will fall below 65°F (18°C.)   • It may cause electrical shock.   • It should withstand around   90 lbs (40kg) of weight.   • Low temperatures could cause   coils to frost and unit may not   start.   Close all doors, windows and other outside   openings to the room.   Do not put a pet or house plant where it will be   exposed to direct air flow.   • The dehumidifier must be operated in an enclosed   • This may injure the pet or plant.   area to be most effective.   4 Download from Www.Somanuals.com. All Manuals Search And Download.   Operating Instructions   Features   This section contains captioned illustrations of your dehumidifier. Use the drawings to become familiar   with all parts and features and what they look like.   Auto   Shut-Off   Light   Fan Speed   Humidistat   Air Filter   Cabinet   Bucket   Front   Grille   Electrical requirements   OBSERVE ALL LOCAL CODES AND ORDINANCES.   DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE   THE POWER SUPPLY CORD GROUND PRONG.   Electrical ground is required on this appliance.   A 115-volt 60 Hz, AC only, 15A fused and properly   grounded electrical supply is required. A time delay   fuse or time delay circuit breaker is required.   Use a dedicated circuit, serving only this appliance.   Do not use an extension cord.   3-prong   grounding   type wall   receptacle   3-prong   grounding   plug   Ground   prong   Power   supply   cord   Recommended grounding method   For your personal safety, this appliance must be grounded. This appliance has a power supply cord   with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a   mating grounding type wall receptacle, grounded in accordance with the latest edition of the National   Electrical Code (ANSI/NFPA 70) and all local codes and ordinances. If a mating wall receptacle is not   available, it is the personal responsibility and obligation of the customer to have a properly grounded   3-prong wall receptacle installed by a qualified electrician.   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Operating your dehumidifier   Control   Your dehumidifier has a control panel containing an indicator and two controls —   Auto Shut-Off, Fan Speed, and Humidistat.   Auto Shut-Off ---This lamp glows when the bucket is full or is missing.   Fan Speed --- This controls the speed of the airflow.   Humidistat --- This controls the moisture in the room.   Unit operation   1. Turn the Humidistat to Off. Plug the power supply cord into an electrical outlet.   2. The Humidistat can be set anywhere between Off and Max for normal operation.   If you need more dehumidification, turn the Humidistat toward Max. If you need less dehumidification,   turn the Humidistat toward Off.   3. Turn the Humidistat to Off to stop the unit.   4. If you want to control the speed of air flow, turn the Fan Speed toward Low or High.   NOTE: The Fan and compressor will not operate for about two minutes to protect the compressor   when you turn the unit off and immediately back on.   De-icer control (invisible)   The Defrost Control senses frost build-up on the evaporator coil and automatically shuts off the   compressor. The fan continues to run, drawing air across the coil, and melting the frost. When the coil is   defrosted, the compressor automatically restarts, and dehumidifying resumes.   NOTE: Do not operate the dehumidifier at temperature below 65°F (18°C.) If your dehumidifier runs when   the temperature and humidity conditions of room are low, frost can form on its evaporator coil. This   interferes with proper operation. Therefore, dehumidifying performance may be reduced.   6 Download from Www.Somanuals.com. All Manuals Search And Download.   Automatic shut off   The dehumidifier will turn off automatically when the bucket is   full, removed or not replaced in the proper position.   The bucket must be replaced in the proper position for the   dehumidifier to work. The light will be on and the dehumidifier   will not run if the bucket is not in the proper position.   Water level   control switch   Disposing of collected water (3 methods)   1. Empty the bucket manually.   When the bucket is full, pull out and   empty it into a large sink or tub and   then replace it properly.   2. Place the dehumidifier directly 3. Attach a length of garden hose   over drain.   to the threaded bucket drain   hose connection to carry water   to the drain.   The bucket has a threaded hose   connection which can be left open.   Drill a 1/4" (6.4 mm) hole in the   center of the hose connection.   Once opened, the hose connection   will continually drain water from the   bucket.   When being attached to the bucket   drain hose connection, be sure the   hose doesn’t kink or bend. It should   lie flat from the dehumidifier to the   drain.   NOTE: The bucket must be   positioned properly making sure   slots on the back of bucket are   positioned correctly.   NOTE: The hose attachment will   accept a standard garden hose   filling. You can attach a screw-on   cap to use the bucket without a   hose.   NOTE: The nozzle cannot be fixed   after puncture. Use an ordinary   garden hose cap to reclose if   necessary.   NOTE: Do not overtighten the hose   when connecting it to the bucket.   Use a rubber washer and tighten   by hand firmly without stripping   the plastic threads.   Drill   7 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Instructions   Installing the dehumidifier properly   1. Allow at least 12 inches of space on all sides of the unit for good air circulation.   2. Install your dehumidifier on a floor, table, or shelf. When installing the dehumidifier on a table   or shelf, make sure the table or shelf is strong enough to support the weight of the dehumidifier   with a full bucket. Do not sit or stand on the dehumidifier.   NOTE: The height of a table or shelf might provide a better position from which to handle the   bucket and help prevent icing of the coils due to colder air near the floor (such as in a   basement.)   3. Lift the bucket and place it in the dehumidifier, making sure the slots on both sides of the   bucket are positioned correctly.   4. Rollers let you move the dehumidifier easily.   12"   12"   Choosing the proper location for your dehumidifier   • Use the dehumidifier in a   basement to help prevent   moisture damage.   • Use the dehumidifier in   laundry drying, bathing, and   dishwashing areas which have   excessive moisture.   • Use the dehumidifier to   prevent moisture damage   anywhere books are stored.   8 Download from Www.Somanuals.com. All Manuals Search And Download.   Care and Maintenance   Your dehumidifier is designed to serve you year-   round. It needs practically no attention. However,   you should check your dehumidifier and inspect the   coils annually.   Electrical Shock Hazard   • Disconnect power supply cord from receptacle before   performing any maintenance.   You may want an Authorized Service Center to   perform this annual checkup. (Cost of the inspection   is the owner’s responsibility.)   • Be careful when cleaning the coils.   Fins are sharp.   OR   Failure to follow the above precautions could result in   electrical shock or personal injury.   If you are familiar with electrical appliances and their   functions, listed below are instructions which would   allow you to perform the inspection and   maintenance for yourself.   Cleaning the front grille and case   Clean the front grille and the cabinet with a soft   cloth, warm water, and a mild detergent.   Do not use bleach or abrasives.   2 Cleaning the air filter   1-1. First, flex the filter at the lower right corner.   Second, slide the upper right side to the left.   1 Then, release all of the tabs and remove   the filter.   1-2. Wash air filter with warm water and a mild   detergent. Rinse and dry it.   Replace dry air filter.   Cleaning the coil   2-1. Remove air filter from the cabinet (see step   1 above).   2-2. Brush the coil gently like arrow in the figure,   if necessary, with warm water and a mild   detergent. Rinse and dry them thoroughly.   Be careful not to spray the coil with a   water hose.   Be careful! Sharp edges!   9 Download from Www.Somanuals.com. All Manuals Search And Download.   Troubleshooting Tips   Before you call for service, review this list. It may save time and money.   The list includes common occurrences that are not the result of defective workmanship or materials in this   appliance.   WHAT TO DO   POSSIBLE CAUSES   FIND YOUR PROBLEM HERE   DEHUMIDIFIER DOES NOT   OPERATE   Plug is disconnected from outlet.   Push plug firmly into wall outlet.   The fuse is blown/circuit breaker is   tripped.   Check the house fuse/circuit breaker box   and replace fuse or reset the breaker.   The dryness level you selected has   been reached.   Dehumidifier automatically shuts off   when the selected amount of moisture   has been removed from the air. If you   want to remove more moisture, turn the   Humidistat to Max. After the dehumidifier   starts, reset the control to the desired   setting.   The Auto Shut-Off light is on.   Dehumidifier automatically shuts off   when the bucket is full. Empty the bucket   and replace.   Dehumidifier is not turned on.   Humidistat is set too high.   Turn on the Humidistat.   Turn the Humidistat to a lower setting.   Close all windows or doors to outside.   DEHUMIDIFIER RUNS TOO   MUCH   Windows or doors near dehumidifier   are open to outdoors.   Check with your dealer to see if capacity   Area to be dehumidified is too large. is adequate.   Front grille may be dirty.   Air movement through dehumidifier   is blocked.   Use a soft cloth, warm water, and a mild   detergent to clean the grille.   Dehumidifier's coils on the back of unit   may be dirty. Clean the soil on the coils   on the back of the unit.   Dehumidifier must be placed in a space   that does not restrict air flowing into the   rear coil or out of the front grille.   Dehumidifier will not turn off if Humidistat   Humidistat is set at Max.   is at Max.   Frost will usually disappear within 60   minutes.   FROST APPEARS ON   COILS   Room temperature is too low.   Room temperature is below 65°F   (18°C.)   This is a normal sound.   Air is moving through the   dehumidifier.   FAN NOISE   10   Download from Www.Somanuals.com. All Manuals Search And Download.   Dehumidifier has been installed or   restarted recently.   DEHUMIDIFIER DOES NOT   DRY THE AIR AS IT SHOULD   • The more moisture in the room air,   the longer it takes for the room air to   become dry.   Airflow is restricted.   • Make sure there are no curtains,   blinds, or furniture blocking the front   or back of the dehumidifier.   The control may not be set high   enough.   • Turn the knob to a higher number.   Doors and windows may not be   closed tightly.   • Check that all doors, windows, and   other openings are securely close.   Clothes dryer may be blowing   moisture-laden air into the room.   • Install the dehumidifier away from   the dryer. Dryer should be vented to   the outside.   Room temperature is too low.   • The unit will not effectively operate   satisfactorily if the room   temperature is below 65°F (18°C.)   11   Download from Www.Somanuals.com. All Manuals Search And Download.   FRIEDRICH AIR CONDITIONING CO.INC.   Post Office Box 1540 ¥ San antonio, Texas 78295-1540   4200 N. Pan Am Expressway ¥ San Antonio, Texas 78218-5212   (210) 357-4400 ¥ FAX (210) 357-4480   DEHUMIDIFIERS   LIMITED WARRANTY   FIRST YEAR   ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date   of original purchase, FRIEDRICH will repair the product at no charge, provided the product is transported to a Friedrich Authorized   Service Center for repair. ALL transportation charges are the sole responsibility of the owner. This remedy is expressly agreed to be   the exclusive remedy within twelve months from the date of the original purchase.   SECOND THROUGH FIFTH YEAR   SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser   coil, dehumidifying coil, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your dehumidifier fails   because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance   and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the   problem, removal, freight charges, and transportation of the dehumidifier to and from the Service Agency, and the reinstallation   charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This   remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.   APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District   of Columbia, and Canada. This warranty is not applicable to:   1. Air filters or fuses.   2. Products on which the model and serial numbers have been removed.   3. Products which have defects or damage which results from improper installation, wiring, electrical current characteris-   tics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the prod-   uct and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restric-   tions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.   OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service Organiza-   tion in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write to: Room Air   Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.   LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty notwithstand-   ing, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMIT-   ED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY   LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.   NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of con-   sequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.   OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.   PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.   All service calls for explaining the operation of this product will be the sole responsibility of the consumer.   All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to   repairs being made.   Revised (01/02)   P/NO. 3828A30059J   920-137-00 (01/02)   Download from Www.Somanuals.com. All Manuals Search And Download.   |