Quality Refrigeration
OWNER’S MANUAL
Instructions for the installation, operation
and maintenance of Traulsen:
Full Size Undercounter Quick Chiller
TU048QC Model
* Traulsen’s quick chillers are solely intended for quick chilling, and not for use as holding cabinet.
This Traulsen unit is built to our highest quality standards. We build our equipment this way as a matter of pride. This phi-
losophy has made Traulsen the leader in commercial refrigeration since 1938. We thank you for your choice and confidence
in Traulsen equipment and we know you will receive many years of utility from this equipment.
All Traulsen units are placed on a permanent record file with the service department. In the event of any future questions you
may have, please refer to the model and serial number found on the name tag affixed to the unit. Should you need service,
call us on our toll free number, 800-825-8220 between 7:30 am - 4:30 pm CST, Monday thru Friday. You may also log onto
www.traulsen.com for further information. It is our pleasure to help and assist you in every possible way.
INSTALLER
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION
INITIAL START DATE:
MODEL TYPE:
SERIAL NO.
COMPANY/INDIVIDUAL NAME:
INSTALLER:
FORM NUMBER TR35906 (REV. 06-26-15)
P/N 375-60305-00
Download from Www.Somanuals.com. All Manuals Search And Download.
II. RECEIPT INSPECTION
III. INSTALLATION (cont’d)
All Traulsen products are factory tested for performance III. c-INSTALLING/ADJUSTING LEGS OR
and are free from defects when shipped. The utmost care
has been taken in crating this product to protect against
damage in transit.
CASTERS:
To install legs or casters, slide leg or caster into the caster chan-
nel from the side of the unit without the refrigeration system.
You should carefully inspect your unit for damage during
delivery. If damage is detected, you should save all the
crating materials and make note on the carrier’s Bill Of
Lading describing the damage. A freight claim should be
filed immediately. If damage is subsequently noted during
or immediately after installation, contact our customer care
team to file a freight claim. There is a fifteen (15) day limit
to file freight damage with the carrier. Under no condition
may a damaged unit be returned to Traulsen without first
obtaining written permission (return authorization). You
may contact Hobart/Traulsen customer care at 800-
333-7447 to request a return or file a claim.
To adjust the legs or casters, loosen the two bolts and move
leg or caster to desired location, spacing between leg or caster
not to exceed 39 inches. Leg or caster on each end of the unit
can not exceed 8 inches from the end of the cabinet.
NOTE: Traulsen recommends to position legs or casters under
the mullion when possible.
CASTER CHANNEL
III. INSTALLATION
CASTER PLATE
BOLT
III. a-LOCATION:
Select a proper location for your unit, away from extreme
heat or cold. Allow enough clearance between the unit
and the side wall in order to make use of the door stay
open feature at 1200 (self-closing feature operates up to
900). The door must be able to open a minimum of 900 in
order to make use of the maximum clear door width. Al-
low a minimum of 12 inches (high) above the cabinet for
proper air circulation.
III. d-CORD & PLUG:
All self-contained models are shipped standard with a NEMA
5-15P plug and 9 foot cord . Select only a dedicated electrical
outlet for power source.
III. b-PACKAGING:
Your Traulsen unit is shipped from the factory bolted to a
sturdy wooden pallet in stretch wrapped material.
o not cut or remove the round grounding
prong from the plug. Do not use an extension cord.
III. e-POWER SUPPLY:
Most exterior stainless steel surfaces have a protective
vinyl covering to prevent scratching during manufactur-
ing, shipping and installation. After the unit is installed in
place of application peel, remove and discard the covering
from all surfaces.
The supply voltage should be checked prior to connection to
be certain that proper voltage for the cabinet wiring is available
(refer to the serial tag to determine correct unit voltage, see
page 1). Make connections in accordance with local electrical
codes. Use qualified electricians.
To remove the wooden pallet, first if at all possible, we
suggest that the cabinet remain bolted to the pallet dur-
ing all transportation to the point of final installation. The
bolts can then be removed with a 1/2” socket wrench.
Avoid laying the unit on its front, side or back for removal
of the pallet.
Use of a separate, dedicated circuit is required. Size wiring
to handle indicated load and provide necessary over current
protector in circuit (see amperage requirements on the unit’s
serial tag).
NOTE: Traulsen does not recommend laying the unit on
its front, side or back. If you must, please allow the unit to
remain in an upright position for 24 hours before plugging it
in so that the compressor oils and refrigerant may settle.
-2-
Download from Www.Somanuals.com. All Manuals Search And Download.
IV. OPERATION
V. CARE & MAINTENANCE
IV. a-QUICK CHILLER OPERATION:
V. a-CLEANING THE CONDENSER/FILTER:
The most important thing you can do to insure a long,
reliable service life for your Traulsen is to regularly clean
the condenser coil and filter.
The Quick Chiller does not require manual defrosting. During
normal operation, a Quick Chiller continuously circulates below
freezing cabinet air through the coil. The coil requires a periodic
defrosting for proper operation. This is accomplished by an
automatic, time activated, temperature/time terminated, defrost
program, utilizing hot gas from the refrigeration system. The
controller is preset at the factory for six equally spaced defrost
cycles within each 24-hour period. The control will read “dEF”
and the green snowflake icon will be illuminated.
The microprocessor control will notify you through a
“CLN-FIL” message when the condensing temperature
of the refrigerator reaches 140 degrees F or greater. If
the condensing temperature reaches 160 degrees F
the compressor will automatically turn off . When the
temperature drops below 140 degrees F the compressor
will restart and when the temperature drops below 120
degrees F the alarm will reset.
SNOWFLAKE ICON
°F
°C
SET
Disconnect electrical power supply
before cleaning any parts of the unit.
To clean the condenser/filter, first disconnect electrical
power to the cabinet and remove the front louver as-
sembly. To do so, place hands under the louver panel
and pull out and up to get louver panel off bracket of the
unit. (See diagram below, image shown with optional
drawer(s).
At the start of a Quick Chiller defrost cycle, the compressor,
condenser fan and evaporator fan shut off. The hot gas relay
will be energized, this will energize the hot gas solenoid valve
thru the normally open contacts and the condenser fan circuit
will be de-energized thru the (normally closed contacts), and the
compressor will restart. When the evaporator coil sensor reaches
400 F the coil is fully defrosted or if the maximum time of defrost
duration (20 minutes) is reached (which ever comes first) then
the defrost hot gas relay is de-energized. The condenser fan
restarts and the hot gas solenoid valve closes, The compressor
system returns to the cooling mode. Total refrigeration system
operation is then resumed (green snowflake icon goes out) and
the display will show def for an additional 10 minutes then return
to reading the inside cabinet temperature. The evaporator fan(s)
are delayed from starting at the termination of the defrost cycle
and will automatically resume by time or temp delay (5 minutes
or 300 F coil sensor temperature, whichever comes first ).
Proceed to vacuum or brush any dirt, lint or dust
from the finned condenser coil/filter, the compressor and
other cooling system parts. If significant dirt is clogging
the condenser fins or filter, use compressed air to blow
this clear. To replace the louver assembly reverse the
process.
During Quick Chiller defrost operation, heat is confined to the coil
enclosure to prevent any significant rise in temperature within the
food zone. The fan delay control function upon termination of a
defrost cycle is two-fold. First, to prevent blowing warm air into
the food storage area. Second, to prevent any condensation on
the defrost coil from being blown into the food storage area.
The microprocessor control is set from the factory to terminated
defrost at 20 minutes in the event of sensor failure. This setting
should never be tampered with, without first consulting Traulsen’s
Technical Service department at 800-825-8220.
-3-
Download from Www.Somanuals.com. All Manuals Search And Download.
V. CARE & MAINTENANCE (cont’d)
VI. DOOR
V. b-REPLACING THE GASKETS:
VI. a-DOOR:
To remove the gasket to be replaced, grasp it firmly by
one corner and pull it out. Before attempting to install
a new gasket, both the unit and the gasket itself must
be at room temperature. Insert the four corners first by
using a rubber mallet (or hammer with a block of wood).
After the corners are properly inserted, work your way
towards the center from both ends by gently hitting with
a mallet until the gasket is completely seated in place
(see figure below for proper gasket placement).
Your Traulsen Full Size Undercounter Quick Chiller model door
is field re-hingeable. If re-hinging is required, please contact our
in-house service department at 800-825-8220 for instructions.
NOTE: The gasket may appear too large, but if it is in-
stalled as indicated above it will slip into place.
GASKET ASSEMBLY
SIDE DOOR PANEL
VERTICAL GASKET
RETAINER
V. c-CLEANING THE CABINET SURFACES:
Disconnect electrical power supply
before cleaning any parts of the unit.
Exterior stainless steel should be cleaned with warm wa-
ter, mild soap and a soft cloth. Apply with a dampened
cloth and wipe in the direction of the metal grain.
Avoid the use of strong detergents and gritty, abrasive
cleaners as they may tend to mar and scratch the sur-
face. Do NOT use cleansers containing chlorine, such
as bleach, this may promote corrosion of the stainless
steel.
Care should also be taken to avoid splashing the unit with
water, containing chlorinated cleansers, when mopping
the floor around the unit.
For stubborn odor or spills, use baking soda and water
(mixed to a 1 tablespoon baking soda to 1 pint water
ratio).
A stainless steel polish is recommended for shining of
unit.
-4-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL
Your new cabinet is equipped with a state-of-the-art microprocessor control, which precisely regulates operation and
provides alarms when problems occur. It is supplied from the factory completely ready for use and requires no adjust-
ments, but without the audible alarms activated. See pages 6 thru 16 for more information on the microprocessor
control.
L
°F
°C
SET
MICROPROCESSOR CONTROL
VII. a-CONTROL FEATURES:
1) Internal Time Clock
• Eliminates external defrost time clock.
• Defrost cycle can be quickly adjusted to suit individual location and use.
• Must be set at power-up. (See page 11, “Setting the 24-Hour Clock”)
• Will automatically update for Daylight Savings Time.
2) Water Resistant Housing
The face of the control is water resistant to provide for protection during cleaning.
3) Parameter/Service Levels
• See “Customer Access Code on Page 8 / Service Parameters” on Page 9.
4) Defrost Lockouts
See “Setting Defrost Lockouts” on page 14.
Customers can set up to 4 different defrost lockout periods. The lockout prevents the unit from going into a defrost
cycle during peak kitchen use. Note: The 24-hour clock must be set for this feature to operate correctly.
5) Communication Ability
A NAFEM Data Protocol (NDP) compliant RS-485 serial communications port is available to interface with data collec-
tion software (by others). All microprocessor control equipped models are capable of communicating within a NAFEM
Data Protocol network if provided with an optional Gateway Hub (available from Traulsen). The actual communications
software is available from a number of third party software vendors.
6) Anti-Condensate Door Perimeter Heater Control
The “No-Sweat” feature is an energy savings system that allows the customer to adjust the percent of time for the door/
drawer heater to be “On” as needed for the prevailing ambient conditions (from 0 - 100% of the time each day). It is
used to prevent condensation from forming around the perimeter of the drawers. The factory default setting is 100%.
Adjust this set point down to a point just before condensation forms to save energy.
7) Alarms
See the following pages for explanations
• High Cabinet Air Temperature
• Low Cabinet Air Temperature
• Loss Of Power
• Sensor Failure
• Clean Condenser
8) Display Features
• 3-Digit LED Display
• Defrost in Progress Icon
• Fahrenheit or Celsius Temperature Scale In Use
-5-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. b-ALARM EXPLANATIONS:
NOTE: Explanation of alarms assume the audible alarm style is set at a 3-second burst or a continuous audible alarm.
References to the audible alarm do not apply if the audible alarm style is set to OFF (Refer to page 16 for setting the
audible alarm style).
High Cabinet Air Temperature: The audible alarm will sound and the display will read HI
CAb when the temperature inside the cabinet rises above a pre-programmed limit. The limit is
determined by the type of unit being operated (i.e.: refrigerator/freezer). To turn off the audible
alarm, press the alarm cancel button. The visual alarm text will continue to display until the
cabinet air temperature falls below the limit. If the temperature does not fall below the limit
within 5 minutes, the audible alarm* will sound again and an additional Call Service message
will display.
Possible Causes:
• Doors open for extended periods of time.
• Large amounts of hot product placed inside the cabinet.
• Condenser coil dirty.
• Cooling Compressor Failure. Call Service.
• Refrigeration Problems.
Low Cabinet Air Temperature: The audible alarm will sound and the display will read Lo
Cab when the temperature inside the cabinet falls below a pre-programmed limit. The limit is
determined by the type of unit being operated (i.e.: refrigerator/ freezer). To turn off the audible
alarm, press the alarm cancel button. The visual alarm text will continue to display until the
cabinet air temperature rises above the limit. If the temperature does not rise above the limit
within 5 minutes, the audible alarm will sound again and an additional Call Service message
will display.
Possible Causes:
• No product in unit.
• Failed sensors.
• Stuck Evaporator Relay.
Loss Of Power: The audible alarm will sound and the display will read ELE LOS, when the
unit regains power after an outage. To turn off the audible alarm and/or clear the visual text,
press the alarm cancel button.
Condenser Clean: The audible alarm will sound and the display will read “Clean Filter” when
discharge temperatures exceeds 140 degrees. As the load on the condenser decreases, the
alarm will turn off by itself. As the temperature on the condenser continue to rise, the audible
alarm will return until the problem has been eliminated.
NOTE: If discharge temperature rises above 1600F the compressor & condenser fan motor
will be switched off until the discharge temp falls below 1400F
Sensor Failures:
The audible alarm will sound and the display will read CAB SEN, COL SEN or DIS SEN when
that particular sensor has failed to operate. To turn off the audible alarm, press the alarm
cancel function of the sensor, the audible alarm will sound again in either 5 minutes or 24
hours.
NOTE: Test sensor in ice water.
-6-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. c-CONTROL PANEL DIAGRAM:
GREEN SNOWFLAKE ICON
SET BUTTON
0F LED & 0C LED
SET
°F
°C
UP BUTTON &
DOWN BUTTON
RED ALARM LIGHT
ALARM CANCEL BUTTON
LED DISPLAY
VII. d-NOTES TO THE USER:
You only have 20-30 seconds between button pushes. If you take longer than 30 seconds, the controller will revert back
to displaying the cabinet temperature. If you enter the wrong security code, the controller will revert back to displaying
the cabinet temperature. You can exit the parameters at any time by pressing the alarm cancel button or by waiting 20-30
seconds.
-7-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. e-ENTER THE CUSTOMER ACCESS CODE:
Use the security code 0, A, 1
and the following instructions:
Press the set button
Press the set button
.
.
The display will read
Service Access.
SET
SET
The display will show three zeros with the left zero flashing
Press the set button
.
SET
The display will show three zeros with the center zero flashing
Press the down arrow key
When you reach A press set
to sequence through F, E, d, C, b, A, 9, 8, 7,…etc.
.
SET
The display will show zero, A, zero with the right zero flashing
.
Press the up arrow key
When you reach 1 press set
The display will read
to sequence through 1, 2, 3, 4, 5, 6, 7, 8, 9, A, b,…etc.
.
SET
Thermostat Set Point High. Press
to view and
again to exit.
SET
SET
You are now in the SERVICE PARAMETERS.
-8-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. f-SERVICE PARAMETERS:
Listed below are the available parameters in the order they appear, using the down arrow key on the controller. You can
use either the up or down arrow keys to scroll through the options.
Thermostat Set Point High
Thermostat Set Point Low
Temperature Scale
Defrost Lockout 3
Defrost Lockout 4
Dew Point Compensation Factor
Room Temperature Offset
Audible Alarm Style
Time (24-hour clock)
Date (month-day-year)
Daylight Savings
Cabinet Air Sensor Temp
Evaporator Coil Sensor Temp
Discharge Line Sensor Temp
Start Manual Defrost
Defrost Lockout 1
Defrost Lockout 2
VII. g-ADJUSTING THERMOSTAT SET POINT HIGH:
This parameter sets the high point of the desired cabinet temperature range. Typically, Quick Chillers will range from 31°F
to 35°F. This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so.
Note: Set Point Low and Set Point High cannot be set to the same temperature. There must be at least 1-2 degree differ-
ence between the two settings.
Follow the instructions to enter the customer access code on page 8. When the control
SET
display reads
Thermostat Set Point High. Press the set button
.
Use the arrow keys
to adjust the temperature to your desired setting.
SET
When the display shows the temperature you want press the set button
.
The display will then read
Thermostat Set Point High.
You can use the up or down arrow keys to scroll to the next parameter
.
)
)
)
or press the alarm cancel button to exit
.
-9-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. h-ADJUSTING THERMOSTAT SET POINT LOW:
This parameter sets the low point of the desired cabinet temperature range. Typically, Quick Chillers will range from 31°F
to 35°F. This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so.
This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so. Note: Set
Point Low and Set Point High cannot be set to the same temperature. There will be at least 1-2 degree difference between
the two settings.
Follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set High, press the down arrow key
Thermostat Set Point Low. Press the set button
until the control
SET
display reads
.
Use the arrow keys
to adjust the temperature to your desired setting.
SET
When the display shows the temperature you want press the set button
.
The display will then read
You can use the up or down arrow keys to scroll to the next parameter
or press the alarm cancel button to exit
Thermostat Set Point Low.
.
.
)
)
)
VII. i-CHANGING THE TEMPERATURE SCALE:
The temperature scale determines if the temperature displayed will be in degrees Fahrenheit or degrees Celsius.
Follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set High, press the down arrow key
Temperature Scale. Press the set button
until the control
display reads
.
SET
for degrees Fahrenheit
to toggle between the options.
The display will start with the current setting either
or for degrees Celsius. Use the arrow keys
When the dsplay shows the scale you want press the set button
.
SET
The display will then read
Temperature Scale.
to scroll to the next parameter
You can use the up or down arrow keys
or press the alarm cancel button to exit
)
.
)
)
-10-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. j-SETTING THE 24-HOUR CLOCK:
The internal time clock must be set in order for the data storage memory to correctly log events and to allow any defrost
lockout to occur at the correct time of day. If the clock is not set, the control assumes the time is 12 am at the time power
is supplied to the unit. The hours on a 24-hour time clock read the following way:
H01 = 1:00 a.m.
H02 = 2:00 a.m.
H03 = 3:00 a.m.
H04 = 4:00 a.m.
H05 = 5:00 a.m.
H07 = 7:00 a.m.
H08 = 8:00 a.m.
H09 = 9:00 a.m.
H10 = 10:00 a.m.
H11 = 11:00 a.m.
H13 = 1:00 p.m.
H14 = 2:00 p.m.
H15 = 3:00 p.m.
H16 = 4:00 p.m.
H17 = 5:00 p.m.
H19 = 7:00 p.m.
H20 = 8:00 p.m.
H21 = 9:00 p.m.
H22 = 10:00 p.m.
H23 = 11:00 p.m
H06 = 6:00 a.m.
H12 = 12:00 p.m.
H18 = 6:00 p.m.
H24 = 12:00 a.m.
Follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set High, press the down arrow key
until the control
SET
display reads
Clock. Press the set button
.
The display will show
Use the arrow keys
Hours. The right two numbers will be flashing.
to set the hour.
SET
When the correct hour is displayed, press the set button
.
The display will show
Minutes. The right two numbers will be flashing.
Use the arrow keys to set the minutes
.
SET
When the correct minutes are displayed, press the set button
The display will then read Clock.
.
You can use the up or down arrow keys
or press the alarm cancel button to exit
to scroll to the next parameter
)
)
)
.
-11-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. k-SETTING THE DATE:
The date must be set in order for the data storage memory to correctly log events. Follow the instructions to enter the
customer access code on page 8. When the control displays
Thermostat Set Point High, press the down
SET
arrow key
show
until the control display reads
Date. Press the set button
. The display will
to set the year.
(year). The right two numbers will be flashing. Press the arrow keys
SET
When the correct year is displayed, press the set button
. The display will show
(month). The right
two numbers will be flashing. Use the arrow keys
to set the month. When the correct month is dis-
SET
played, press the set button
Press the arrow keys
.
The display will show
(day). The right two numbers will be flashing.
SET
to set the day. When the correct day is displayed, press the set button
.
The display will then read
Date. You can use the up or down arrow keys
to scroll to the
)
)
)
next parameter, press the alarm cancel button to exit
.
VII. l-SETTING DAYLIGHT SAVINGS TIME:
This parameter is preset at the factory to automatically adjust the 24-hour clock for Daylight Savings Time. Follow the
instructions to enter the customer access code on page 8. When the control displays
Thermostat Set Point
High, press the down arrow key
until the display reads
Daylight Savings Time. Press the set
SET
button
. The display will show
Daylight Savings Time (Yes, automatically adjust for Daylight Savings
SET
Time). For “YES” press the set button
,for “NO” press the up or down arrow key
. The
SET
display will read
Daylight Savings Time (no). Press the set button
. The display will read
Daylight Savings Time. You can press the up or down arrow keys
to scroll to the next parameter or
)
)
)
press the alarm cancel button to exit
.
-12-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. m-STARTING A MANUAL DEFROST CYCLE:
This parameter allows a service technician to start a defrost cycle at any time. This parameter will override any lock-
out settings. Follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set High, press the down arrow key
until the control display reads
Start Manual Defrost.
Press the set button
SET
The display will show
Press either arrow key
The display will show
Press the set button
SET
DEFROST ICON
The defrost icon will be lit, and the display will
read
when the unit is in defrost.
NOTE: Traulsen Quick Chiller units also have an off-cycle defrost, at which time the control will read
This defrost is temperature terminated and can last from 3 - 20 minutes (dEF will be displayed for 20-37 minutes
time).
-13-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. n-SETTING THE DEFROST LOCKOUTS:
The defrost lockout parameters allow the customer to prevent the unit from going into a defrost cycle for two hours during
a set time frame. Customers can set up to four defrost lockout parameters. They are all programmed the same way. The
parameters will be set for the time the lockout is to start. The controller automatically calculates 2 hours from that setting.
The options are similar to the 24-hour clock settings and are in 30-minute increments. Each of the lockout parameters
covers 6 hours of the 24-hour clock. Note: The 24-hour clock must be set for this feature to operate at the correct time of
day. See “Setting the 24-Hour Clock” on page 11.
Sample:
OFF
OFF
OFF
OFF
020 = 2:00 a.m.
023 = 2:30 a.m.
030 = 3:00 a.m.
033 = 3:30 a.m.
040 = 4:00 a.m.
043 = 4:30 a.m.
050 = 5:00 a.m.
053 = 5:30 a.m.
060 = 6:00 a.m.
063 = 6:30 a.m.
070 = 7:00 a.m.
073 = 7:30 a.m.
080 = 8:00 a.m.
080 = 8:00 a.m.
083 = 8:30 a.m.
090 = 9:00 a.m.
093 = 9:30 a.m.
100 = 10:00 a.m.
103 = 10:30 a.m.
110 = 11:00 a.m.
113 = 11:30 a.m.
120 = 12:00 p.m.
123 = 12:30 p.m.
130 = 1:00 p.m.
133 = 1:30 p.m.
140 = 2:00 p.m.
140 = 2:00 p.m.
143 = 2:30 p.m.
150 = 3:00 p.m.
153 = 3:30 p.m.
160 = 4:00 p.m.
163 = 4:30 p.m.
170 = 5:00 p.m.
173 = 5:30 p.m.
180 = 6:00 p.m.
183 = 6:30 p.m.
190 = 7:00 p.m.
193 = 7:30 p.m.
200 = 8:00 p.m.
200 = 8:00 p.m.
203 = 8:30 p.m.
210 = 9:00 p.m.
213 = 9:30 p.m.
220 = 10:00 p.m.
223 = 10:30 p.m.
230 = 11:00 p.m.
233 = 11:30 p.m.
240* = 12:00 a.m.
243* = 12:30 a.m.
010 = 1:00 a.m.
013 = 1:30 a.m.
020 = 2:00 a.m.
* Denotes not available.
A lockout can not be programmed to start at 12:00 am or 12:30 am due to conflicts with other internal programs. The
defrost lockouts can not be programmed to run back-to-back. For example, if dL1 is set to 080, then a defrost cycle
would be locked out from 8:00 am to 10:00 am. Because of the dL1 setting the dL2 parameter would not let the user
choose a lockout start time before 10:30 am. All lockouts are preset at the factory to OFF.
Follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set High, press the down arrow key
until the control the
SET
control display reads
The display will show
or
. Press the set button
.
Off. Press the arrow keys
to set the start time.
SET
When the correct time is displayed, press the set button
The display will then read
.
or
.
You can press the up or down arrow keys
to scroll to the next parameter
)
)
)
or press the alarm cancel button to exit
.
-14-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. o-ADJUSTING THE DOOR/DRAWER PERIMETER HEATERS:
This parameter allows the customer to turn ON and OFF the anti-condensate door/drawer perimeter heaters. This parameter
is set to the highest setting (100) at the factory so that the door/drawer heaters stay on continuously. If you choose to have
the door/drawer heaters cycle on and off, lower this parameter to approximately 30. If condensation forms around the door/
drawers, increase the parameter until condensation stops. The exact setting will vary depending on ambient conditions.
Follow the instructions to enter the customer access code on page 8. When the control displays
Thermostat Set High, press the down arrow key
until the control display reads
SET
DewPoint Compensation Factor. Press the set button
. Press the arrow keys
to adjust the factor to
. The display will then
to scroll to the
SET
your desired setting. When the display shows the factor you want press the set button
read
DewPoint Compensation Factor. You can use the up or down arrow keys
)
)
)
next parameter or press the alarm cancel button to exit
.
VII. p-ADJUSTING THE ROOM TEMPERATURE OFFSET:
Cabinet temperature offset parameter allows a service technician or end user the ability to have the display show a tempera-
ture that is within three degrees of the actual temperature being read by the cabinet air sensor. This allows for continuity of
reading between different temperature reading devices. (i.e.: thermistor vs. thermocouple vs. handheld thermometer) This
parameter is preset at the factory to “-2.50F”.
Follow the instructions to enter the customer access code on page 8. When the control displays
Thermostat Set High, press the down arrow key
Room Temperature Offset. Press the set button
until the control display reads
Use the arrow keys
SET
.
to adjust the offset to your
desired setting. When the display shows the offset you want press the set button SET . The display will then
read
Room Temperature Offset. You can use the up or down arrow keys
to scroll to the next
)
)
)
parameter or press the alarm cancel button to exit
.
-15-
Download from Www.Somanuals.com. All Manuals Search And Download.
VII. MICROPROCESSOR CONTROL (cont’d)
VII. q-SETTING THE AUDIBLE ALARM STYLE:
These parameters will allow the customer to turn on/off the audible alarm feature on the INTELA-TRAUL® control. The
audible alarm is preset from the factory to OFF. The customer can choose between an audible alarm that sounds for 3
seconds then automatically turns off, or a continuous audible alarm that must be manually acknowledged. Regardless of
this feature’s setting, visual alarm text will display when conditions warrant.
To adjust this setting, follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set Point High, press the up arrow key
until the display reads
SET
Audible Alarm Style. Press the set button
. The display will read
OFF. Use the arrow keys
to scroll between
for the 3-Second Audible Alarm Burst or
for Continuous Audible Alarm.
SET
When the display shows your choice of style, press the set button
. The display will then read
ther-
mostat Set Point High. Use the arrow keys
to scroll to the next parameter or press the Alarm Cancel
)
)
)
Button
to exit.
VII. r-VIEWING SENSOR TEMPERATURES:
These parameters allow a service technician or customer to view the temperature of all sensors within the unit. The
temperatures cannot be adjusted.
Follow the instructions to enter the customer access code on page 8. When the control displays Thermostat Set Point
High
, press the up arrow key
or Disharge Line Sensor
unit the display reads
or press the SET button
Cabinet Air Sensor Evaporator Coil
SET
Sensor
. The display will read the
temperature of the designated sensor. Press the UP or DOWN arrow keys
to scroll through the param-
)
)
)
eters or press the ALARM CANCEL button
to exit.
-16-
Download from Www.Somanuals.com. All Manuals Search And Download.
VIII. WIRING DIAGRAM
NOTE: Refer to the wiring diagram below for any service work performed by a qualified technician.
-17-
Download from Www.Somanuals.com. All Manuals Search And Download.
IX. SERVICE ASSISTANCE
IX. a-SERVICE INFORMATION:
Before calling for service, please check the following:
Is the electrical cord plugged in?
Is the fuse OK or circuit breaker on?
Clean condenser coil
Is the power switch on?
Reset microprocessor control values to factory defaults.
If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service
agent. A complete list of authorized service agents was provided along with your Traulsen unit. If you cannot locate this,
you may also obtain the name of a service agent from the service directory tab on our website: www.traulsen.com. If service
is not satisfactory, please contact our in-house service department at:
Traulsen
4401 Blue Mound Road
Fort Worth, TX 76106
(800) 825-8220
NOTE: Traulsen reserves the right to change specifications or discontinue models without notice.
IX. b-SPARE PARTS INFORMATION:
To purchase replacement parts or to speak to service support for Traulsen and most Hobart Refrigeration units please
contact our Ft. Worth facility by phone at 800-825-8220 or fax to 817-740-6748 (parts fax) or 817-740-6757 (service fax).
To source parts locally follow instructions below for nearest location:
2. Select Service Directory (top of screen)
3. Select Locate Parts (left side of screen)
4. Click on State desired
To source service support locally follow instructions below for nearest authorized service agent:
2. Select Service Directory (top of screen)
4. Click on State desired
NOTE: When calling for spare parts or service support, please make sure you have model and serial number of unit avail-
able prior to calling.
IX. c - WARRANTY REGISTRATION:
The warranties for your new Traulsen unit may be registered with us by contacting our Ft. Worth facility by phone at 800-
825-8220 or you may register on line:
2. Select Service Directory (top of screen)
3. Select Warranty Registration Form (left side of screen)
4. Fill out information requested
5. Select Submit to complete unit warranty registration
-18-
Download from Www.Somanuals.com. All Manuals Search And Download.
X. WARRANTIES
STANDARD DOMESTIC WARRANTY
TRAULSEN warrants new equipment to the original purchaser, when installed within the United States against defective
material and workmanship for one (1) year from the date of original installation. Under this warranty, TRAULSEN will repair or
replace, at its option, including service and labor, all parts found to be defective and subject to this warranty. The compressor
part is warranted for an additional four (4) years. During this periodTRAULSEN will supply replacement compressor if deemed
defective, however, all installation, recharging and repair costs will remain the responsibility of the owner. However, all instal-
lation and repair costs will remain the responsibility of the owner. Three year drawer parts warranty on optional drawers.
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of God,
terrorism, attempted repairs, improper installation by unauthorized persons, and will not apply to food loss.
For TRAULSEN units purchased with a remote feature, standard warranty will apply only to those components contained
within the unit to the point of connection of the refrigeration lines leading to the remote compressor.
THERE ARE NO ORAL, STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN, INCLUDING BUT NOT
LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHICH
EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY
FOR CONSEQUENTIAL OR SPECIAL DAMAGES, GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS
SALE, OPERATION OR USE, AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR
IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE, OPERATION OR USE OTHER
THAN AS STATED HEREIN.
MICROPROCESSOR CONTROL WARRANTY
TRAULSEN, warrants to the original purchaser of the microprocessor control when installed as part of the Refrigeration/Hot
Food Equipment manufactured and sold by TRAULSEN, to be free of defects in material and workmanship under normal
service and use for a period of two (2) years from the date of installation. Under this warranty statement, TRAULSEN will repair
or exchange at TRAULSEN’S discretion, F.O.B. factory, any part of said control, which proves to be defective. Inspection by
the TRAULSEN Service Department of parts claimed defective shall be final in determining warranty status. The warranty is
to include repair or exchange of any defective In-Warranty control or part (s) of said control for:
Part (s) –Any TRAULSEN microprocessor control supplied part (s) found to be defective.
Labor –The labor charges from a TRAULSEN Certified Service Agent to effect the repair or exchange of the defective
part(s).
“Defective Part Return” – All claimed defective part(s) must be returned to TRAULSEN for defect validation within
30 days from the date of the repair. Failure to return all claimed defective part(s) to TRAULSEN will invalidate the warranty
claim, this warranty statement, and forfeit payment for those repairs effected.
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of
God, terrorism, attempted repairs, improper installation by unauthorized persons, and will not apply to food loss,
and will not apply if said equipment is located outside The United States.
INTERNATIONAL COMMERCIAL WARRANTY
(for Canadian warranties see domestic US warranty)
TRAULSEN warrants to the original purchaser the Refrigeration Equipment manufactured and sold by it to be free from defects in material and workmanship
under normal use and service for a period of one (1) year from date of shipment. Under this warranty, TRAULSEN will reimburse the purchaser for the replace-
ment of any part of said equipment (excluding dryers & refrigerant gas) which then proves to be defective. This warranty does not apply to damage resulting
from fire, water, burglary, accident, abuse, misuse, transit, acts of God, terrorism, attempted repairs, improper installation by unauthorized persons,
and will not apply to food loss.
TRAULSEN’S standard warranty does not apply to Export Sales. Rather, for a period of one (1) year from date of original installation not to exceed Fifteen (15)
months from date of shipment from factory, TRAULSEN:
will replace, F.O.B. factory, any defective parts normally subject to warranty.
will not cover the cost of packing, freight or labor such costs being the sole responsibility of the dealer/end user.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND CONSTITUTES
TRAULSEN’S FULL OBLIGATION AND LIABILITY. WARRANTIES NOT AVAILABLE ON REMOTE MODELS.
-19-
Download from Www.Somanuals.com. All Manuals Search And Download.
XI. SERVICE PARTS LIST
NOTE: Part numbers listed are for standard units, as currently manufactured. For units manufactured as other than
standard, please contact the factory at 800-825-8220 for part numbers.
ITEM
DESCRIPTION
PART NUMBER
SER-60538-00
CASTER
6’’ ADJUSTABLE CASTER NO LOCK
6’’ ADJUSTABLE CASTER WITH LOCK
4’’ ADJUSTABLE CASTER NO LOCK
4’’ ADJUSTABLE CASTER WITH LOCK
SER-60538-01
SER-60536-00
SER-60536-01
LEG
6’’ ADJUSTABLE LEG
SER-60542-00
DOOR
DOOR ASSEMBLY, HINGED LEFT
DOOR ASSEMBLY, HINGED RIGHT
DOOR GASKET
SK-200-60593-00
SK-200-60593-01
341-60197-00
DRAWER
DRAWER ASSEMBLY
DRAWER FACE ASSEMBLY
DRAWER FRAME ASSEMBLY
DRAWER FRAME INSERT
DRAWER GASKET
SK-550-10108-00
SK-550-10114-00
SK-550-10104-00
SER-60553-00
341-60176-07
DRAWER ROLLER
344-60155-00
SHELF
CHROME SHELF
340-60230-01
340-60240-00
SK-500-70094-00
TRAYSLIDE
LOUVER
UNIVERSAL TRAYSLIDE
LOUVER PANEL
MICROPROCESSOR
MICROPROCESSOR CONTROL HEAD
337-60403-00
337-60405-01
337-60406-01
MICROPROCESSOR CABINET TEMPERATURE SENSOR
MICROPROCESSOR COIL TEMPERATURE SENSOR
MICROPROCESSOR LIQUID LINE TEMPERATURE SENSOR 337-60407-01
MICROPROCESSOR RELAY MODULE
337-60317-00
-20-
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES:
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES:
Download from Www.Somanuals.com. All Manuals Search And Download.
HOURS OF OPERATION:
Monday thru Friday 7:30 am - 4:30 pm CST
Traulsen
4401 Blue Moud Road Fort Worth, TX 76106
Phone (800) 825-8220 Fax (817) 740-6757
Quality Refrigeration
© 2015 Traulsen - All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
|