Data/Voice/Fax Concentrator
Desktop Models: DT101, DT102, DT101/xx, DT102/xx
Rack-Mount Models: DT101R, DT102R, DT101R/xx, DT102R/xx
Owner’s Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Chapter 1 - Introduction and Description
1.1
1.2
1.3
1.4
Introduction.................................................................................................................................... 8
About This Manual......................................................................................................................... 8
Product Description ..................................................................................................................... 10
System Features ......................................................................................................................... 12
1.4.1
Voice/Fax ........................................................................................................................... 12
Data Channel ..................................................................................................................... 12
Composite Link .................................................................................................................. 12
Flow Control....................................................................................................................... 12
Parameter Memory ............................................................................................................ 12
Diagnostics ........................................................................................................................ 13
Operational Statistics ......................................................................................................... 13
1.4.2
1.4.3
1.4.4
1.4.5
1.4.6
1.4.7
1.5
1.6
1.7
FCC Regulations for Telephone Line Interconnection ................................................................. 14
Canadian Limitations Notice ........................................................................................................ 15
Specifications .............................................................................................................................. 16
1.7.1
Async Data Channel .......................................................................................................... 16
Sync Data Channel ............................................................................................................ 16
System Control (Command Port)....................................................................................... 16
Composite Link .................................................................................................................. 16
Internal Modem .................................................................................................................. 17
Internal DSU ...................................................................................................................... 17
ISDN Terminal Adapter ...................................................................................................... 17
Voice/Fax Channel............................................................................................................. 17
Electrical/Physical.............................................................................................................. 18
1.7.2
1.7.3
1.7.4
1.7.5
1.7.6
1.7.7
1.7.8
1.7.9
Chapter 2 - Configuration
2.1
2.2
2.3
2.4
2.5
Introduction.................................................................................................................................. 20
Configuration 1 - Dial-Up Link ..................................................................................................... 21
Configuration 2 - MMH900 Series with Voice/Fax ....................................................................... 25
Configuration 3 - LAN to LAN ...................................................................................................... 28
Configuration 4 - PBX to PBX ..................................................................................................... 32
Chapter 3 - Front and Rear Panel Descriptions
3.1
3.2
3.3
Introduction.................................................................................................................................. 36
Indicators ..................................................................................................................................... 36
Connectors .................................................................................................................................. 39
3.3.1
Frame Ground Connector (GND) ...................................................................................... 39
POWER Connector ........................................................................................................... 39
DATA/COMMAND Connector ............................................................................................ 39
EXTERNAL COMPOSITE RS232C/V.35 Connector ......................................................... 39
VOICE/FAX CHANNEL 1 FXS Connector ......................................................................... 39
VOICE/FAX CHANNEL 1 FXO Connector......................................................................... 39
VOICE/FAX CHANNEL 1 E&M Connector ........................................................................ 40
DSU/TA DIGITAL Connector .............................................................................................. 40
MODEM LEASED Connector ............................................................................................ 40
MODEM DIAL-UP Connector ............................................................................................ 40
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.10
3.4
Switches and Shunts ................................................................................................................... 41
3.4.1
Front Panel Switches ......................................................................................................... 41
Power Switch ..................................................................................................................... 41
DIP Switch ......................................................................................................................... 42
RS232C/V.35 Shunt........................................................................................................... 42
3.4.2
3.4.3
3.4.4
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4 - Unpacking and Configuration
4.1
4.2
4.3
4.4
4.5
4.6
4.7
Introduction.................................................................................................................................. 44
Unpacking ................................................................................................................................... 44
Configuration Summary............................................................................................................... 45
Data Port Configuration Considerations ...................................................................................... 45
Voice/Fax Channel Configuration Considerations ....................................................................... 46
Composite Link Configuration Considerations ............................................................................ 47
Configuration Procedure ............................................................................................................. 48
Chapter 5 - Installation
5.1
5.2
5.3
5.4
Introduction.................................................................................................................................. 56
Cabling ........................................................................................................................................ 56
V.35 Shunt ................................................................................................................................... 60
Power-On and Checkout ............................................................................................................. 61
Chapter 6 - Menus
6.1
6.2
Introduction.................................................................................................................................. 66
Configurations Menu ................................................................................................................... 66
6.2.1
Data Port Configuration ..................................................................................................... 67
Sync Data Port Configuration ............................................................................................ 69
Voice/Fax Channel Configuration ...................................................................................... 70
Composite Link Configuration............................................................................................ 73
6.2.2
6.2.3
6.2.4
6.3
6.4
6.5
Statistics ...................................................................................................................................... 78
Reset Options.............................................................................................................................. 79
Diagnostic Tests .......................................................................................................................... 79
6.5.1
Loop Tests ......................................................................................................................... 80
6.6
Configure Remote Unit ................................................................................................................ 81
6.6.1
6.6.2
MMV8/16/32 Configuration Options ................................................................................... 81
Quick Setup ....................................................................................................................... 82
Chapter 7 - Troubleshooting
7.1
7.2
7.3
7.4
7.5
7.6
Introduction.................................................................................................................................. 88
Importance of the Composite Link Statistics Report.................................................................... 88
Test Cables.................................................................................................................................. 89
Troubleshooting Guide ................................................................................................................ 90
Composite Link Settings - Internal DSU ...................................................................................... 99
Composite Link Settings - Internal ISDN Terminal ..........................................................................
Adapter ...................................................................................................................................... 100
Composite Link Settings - Internal Modem................................................................................ 101
Composite Link Settings - External Device ............................................................................... 102
Composite Link Statistics .......................................................................................................... 103
Data Port Configuration ............................................................................................................. 105
Voice/Fax Channel Configuration .............................................................................................. 107
Diagnostic Testing ..................................................................................................................... 109
7.7
7.8
7.9
7.10
7.11
7.12
Chapter 8 - Warranty, Service and Tech Support
8.1
8.2
Introduction.................................................................................................................................112
Limited Warranty ........................................................................................................................112
8.2.1
On-line Warranty Registration...........................................................................................112
8.3
Tech Support ..............................................................................................................................113
8.3.1
8.3.2
Recording DataTalker Information ....................................................................................113
Service..............................................................................................................................113
8.4
8.5
The Multi-Tech BBS....................................................................................................................114
About the Internet .......................................................................................................................115
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendixes
Appendix A - ASCII Conversion Chart .....................................................................................................118
Appendix B - RS-232C Interface Specification........................................................................................119
Appendix C - Cabling Diagrams ............................................................................................................. 120
Appendix D - Flow Control Background ................................................................................................. 124
Appendix E - MMH2834 Modem S-Registers ........................................................................................ 125
Appendix F - MMH2834 Modem Commands ......................................................................................... 127
Glossary
Index
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1 - Introduction and Description
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
1.1 Introduction
Congratulations! Your new Multi-Tech DataTalker™is one of the finest data/voice/fax
concentrators on the market today. The DataTalker optimizes wide area network (WAN) links by
simultaneously transmitting voice and/or fax with LAN or computer data over a single phone line,
digital service, or ISDN service.
The DataTalker basic model (DT101) supports one asynchronous or synchronous input data
channel, one voice/fax channel, and a synchronous external composite link. Options include a
second voice/fax channel (DT102) and an internal composite link modem (DT101/V34 or DT102/
V34), DSU (DT101/56 or DT102/56), or ISDN terminal adapter (DT101/IS or DT102/IS). It comes
in two basic versions: a desktop version for home offices and a rack-mount version for central
office applications (DT101R and DT102R models). The DataTalker is software driven using
configuration menus, and is controlled by you through its command port for great flexibility and
ease of operation. This Owner’s Manual will help you to install and use your DataTalker, and also
serve as a valuable information resource in the future.
101
MultiMux
Data
/
Voice
/
Fax Concentrator
VOICE
FAX
/
/
FXS
FXS
FXO E&M FAX
FXO E&M FAX
XMT RCV XSG RSG
XMT RCV XSG RSG
RXT
FCR
RD
TM
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
TA
2B
2
COMPOSITE
LINK
STATUS
DATA/
COMMAND
VOICE
FAX
XMT RCV
FC
COM ORIG
CD
RCV XMT CTS
RTS
NS
OOS
1
101 MDM TA
/
Figure 1-1. DataTalker (Desktop Version)
1.2 About This Manual
This manual has eight chapters. There are also several appendices at the end of the manual,
most of which summarize information contained in the chapters. These appendices can be used
as quick references. The information contained in each chapter is as follows:
Chapter 1 - Introduction
This chapter is an introduction to the world of multiplexing. If you already have an extensive
background in multiplexing, this introduction will provide a good review.
Chapter 2 - Configuration Examples
This chapter describes DataTalker configurations and provides examples of how the DataTalker
is typically used. The basic model has a synchronous or asynchronous data channel, a voice/fax
channel, and a composite link supporting synchronous communications. Options include a
second voice/fax channel and an internal V.34 (33.6K bps) modem, 56K bps DSU, or ISDN
terminal adapter.
Chapter 3 - Front and Back Panel Descriptions
Chapter 3 describes the front panel indicators, back panel connections, and switches. The front
panel indicators are grouped into data and command port, voice/fax channels, and composite link
status. The back panel provides all cable connections.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1 - Introduction and Description
Chapter 4 - Unpacking and Configuration
This chapter describes the contents of the shipping container; provides a customizeable
configuration summary; discusses configuration considerations for the data port, voice/fax
channel, and the composite link; and provides a detailed configuration procedure. The
configuration procedure simplifies the process by asking questions about your application, which
allows you to glide through the configuration process by configuring only the items that need to
be changed.
Chapter 5 - Installation
Chapter 5 provides procedures for cabling your DataTalker, moving the V.35 shunt, applying
power, and checking it out. Cabling involves a minimum of three cables. Each cable connection is
explained in detail. If a V.35 interface is used, a procedure on how to move the shunt is provided.
Finally, a power-on and checkout procedure is provided with some suggestions on what to do in
case something goes wrong.
Chapter 6 - Menus
The DataTalker is software driven using menus, and is controlled through a command port
device. This chapter describes the menus and the impact each option has on your system’s
operation.
Chapter 7 - Troubleshooting
This chapter is a guide to troubleshooting your DataTalker. It contains lists of error conditions,
probable causes, and suggested fixes or steps designed to isolate the failing unit in your
communications network.
Chapter 8 - Service, Warranty and Tech Support
Chapter 8 provides instructions on getting service for the DataTalker at the factory; a statement
of the limited warranty; information about our user bulletin board service, and space for recording
information about your DataTalker prior to calling Multi-Tech's Technical Support.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
1.3 Product Description
The DataTalker series of multiplexers has a single synchronous or asynchronous data channel, a
command port, one or two voice/fax channels, and a single synchronous composite link with an
internal data service unit (DSU), modem, ISDN terminal adapter, or an external synchronous link
device. The DataTalker can be connected to an asynchronous device such as a PC or host
computer, an external synchronous device such as a LAN router, or the composite link of an
MMH900 series MultiMux. It also can be connected to telephone equipment for voice or fax traffic
over your standard composite link. The DataTalker’s data port allows either synchronous or
asynchronous devices to be connected to it. The command port allows you to configure your data
channel, composite link, and voice mode of operation. The composite link can be configured for
an internal 28.8K bps dial-up/leased line modem, an internal DSU for digital communications over
a digital data service (DDS) network, or an ISDN terminal adapter for Basic Rate Interface
Service. It can also be configured for external synchronous link devices. The voice/fax channel
supports phone, fax, or key telephone system equipment through an FXS interface, a PBX
station-side connection through an FXO interface, or a PBX trunk connection through an E&M
interface. The DT101/V34 and DT102/V34 DataTalkers are dual-function models. If the user
requires traditional data communications, these models provide a simple switch to enable a
standalone V.34 modem mode, which supports dial-in/dial-out data communications for Internet,
BBS, and other on-line access.
EPROM
AT Commands
C
Configurations
Data/Command
Composite
Link
o
m
p
o
s
i
L
i
n
k
Modem,
DSU, or
Terminal
Adapter
Serial
Communications
Controller
Data/
Command
Channel
I/O
PDN
Processor
t
e
RAM
Port
RAM
Trunk
Trunk
E&M
FXO
FXS
Analog
to
PSTN
Channel 1
CODEC
Trunk
Digitize
Voice/fax
Digital
Station
Station
Digital
A to D
D to A
Signal
RAM
Processor
PBX
Digital
to
Analog
EPROM
1
4
2
7
5
6
3
8
9
Fax/Telephone
Figure 1-2. Block Diagram
A simplified block diagram of the DataTalker is shown in Figure 1-2. The data channel on the top
left and the voice/fax channel on the bottom left feed data to a serial communications controller
that provides the path through a modem, DSU, or ISDN terminal adapter to the public data
network. The data channel, voice/fax channel, and the serial communications controller are on
the main printed circuit board. The internal modem, DSU, or terminal adapter is a daughter board
that plugs into the main board. The data/command channel is a dual purpose channel to which a
synchronous or asynchronous device can be connected when it is used in its data mode. The
voice/fax channel allows you to connect a telephone, a PBX (Private Branch eXchange)
extension, or a PBX E&M trunk for voice or fax communication. On the other end of the
DataTalker, an internal 33.6K bps modem, 56K bps DSU, or ISDN terminal adapter provides the
composite link interface to the public data network.
The data/command channel can have a terminal or PC connected to it for configuring the
DataTalker. The versatility of the data/command port allows the DataTalker to be connected to a
synchronous or asynchronous device in the data mode or to an asynchronous device in the
command mode when the DataTalker needs to have the configuration of the data channel, voice/
fax channel, or the composite link changed. The data/command channel can be switched
between data and command modes by setting a DIP switch. If the data/command channel is in
data mode, it is also possible to switch to command mode by entering the escape command
+++AT<CR>.
Before you can transfer data over the channel, you must connect a terminal or PC running
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1 - Introduction and Description
communications software to the DATA/COMMAND connector on the back panel and configure
the data channel for the type of data that is going to be transferred. For example, if an
asynchronous device is going to be connected to the data channel, you must set the speed of the
channel, the word length, the number of stop bits, whether or not you are going to have parity
checking, the flow control type, and other aspects of asynchronous data. After you have
configured the data channel, remove the command port device and connect the data channel
device, allowing data to be transferred from the asynchronous device to the MultiMux’s input/
output circuitry.
To operate the data channel in synchronous mode, as when connecting to a remote LAN bridge
or to the composite link of an MMH900 series MultiMux, use the same DATA/COMMAND
connector. The sync device you connect to the data channel must be an SLDC or HDLC device.
Configure the data channel for sync channel operation with any SLDC/HDLC protocol , for
internal or external clocking, and for speed. Configuration information is stored in non-volatile
memory, which informs the data/command processor how data is received from the input/output
(I/O) circuitry.
To set up the DataTalker for voice or fax operation, connect the VOICE/FAX CHANNEL 1 FXS
connector on the back panel to a telephone or fax machine, connect the FXO connector to a PBX
station circuit, or connect the E&M connector to a PBX E&M trunk. The FXS (Foreign eXchange
Station) circuitry in the DataTalker allows a telephone or fax machine to be directly connected to
the DataTalker. This circuitry provides a ringing voltage to the remote instrument when it detects
an off-hook condition from the attached device, so that when two telephones are used, picking up
one of the handsets rings the telephone at the other end. If the FXO (Foreign eXchange Office)
connection is used at one end of the network and a telephone set is used at the other end of the
network, the PBX provides the dial tone, and the remote user can dial a number as if locally
attached to the PBX. The E&M connector is used to link two PBXs.
Before a voice or fax operation can take place, the DataTalker must be configured for the types of
local and remote connections and for the line conditioning for the voice circuitry. The voice/fax
channel is configured in the same way as the data channel: by connecting a command port
device to the DATA/COMMAND connector on the back panel and setting the voice/fax
configurations. Once the channel is configured, the analog to digital conversion circuitry accepts
the incoming analog signal and converts it to a digital representation of the signal. The digitized
signal is stored in the dual-port RAM for transmission to the serial communications controller
when it requests the dual-port RAM for data. The serial communications controller conditions the
digitized voice or fax data for transmission to the composite link.
In order to transfer data from the serial communications controller over the composite link to the
remote site, the composite link must be configured. Factors to be considered include whether an
external device or an internal modem, DSU, or terminal adapter or installed, the speed of the link,
who is providing the clocking, and other link conditioning factors. The composite link is
configured using a command port device and menus the same way we configured the data and
voice/fax channels. This is accomplished by setting the link configurations to match the link
device installed in the DataTalker and the requirements of the link service and remote system. If,
for example, an internal DSU is installed that will be connected to a DDS network that provides
clocking, the DataTalker detects that the link device is an internal DSU. Through the configuration
stored in nonvolatile memory, it knows that the clocking is going to be provided by the DDS
network. When you look at the versatility of the composite link, many other factors must be
considered, such as answer or originate, two- or four-wire, and dial-up or leased line operation.
But all these considerations are handled in the same manner as the example of the DSU above.
This is basically how your DataTalker is connected to a data device and voice or fax equipment,
how the internal logic is conditioned to transfer data, and how the composite link passes that data
on to the remote site.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
1.4 System Features
1.4.1
Voice/Fax
The voice/fax feature of the DataTalker allows you to establish voice or fax traffic on top of your
normal data communications over a composite link, saving the expense of extra communications
lines. The DataTalker provides three types of telephone circuits (FXS, FXO, and E&M) that allow
a telephone, a fax machine, a PBX station card, or a PBX E&M trunk to be directly connected to
it. In one configuration, these telephone circuits cause the telephone at a remote location to ring
when you pick up the handset on the local telephone. In another configuration, an off-site
extension moves your office extension to a remote location. In a third configuration, you can use
the DataTalker to tie two PBXes together.
1.4.2
Data Channel
The DataTalker data channel is able to accommodate any asynchronous device or any SDLC/
HDLC synchronous device. Configuration of the data channel is controlled by menus that
determine the mode of operation (sync or async), whether or not clocking is necessary, the
speed of the channel, and a number of async channel conditioning parameters.
1.4.3
Composite Link
The DataTalker’scomposite link is capable of synchronous and full duplex communications with
an internal or external link device. Using an internal modem, ISDN terminal adapter, DSU, or
external device, the DataTalker can be connected to different types of communications links,
such as a dial-up line, a leased line, a Basic Rate Interface (BRI) ISDN service, or a DDS
network. If an external link device is used, the DataTalker can communicate with it using either
the RS232 or V.35 standard.
1.4.4
Flow Control
Flow control regulates the volume of data entering the data port. When the channel buffer is
almost full, a flow control command is issued which tells the device attached to the data port to
stop sending data. The devices on both ends of the link must be configured for the same flow
control method. The most common flow control methods are XON/XOFF and RS232C signal
control (using CTS). The DataTalker supports these and ENQ/ACK.
DATATALKER-INITIATED
FLOW CONTROL
CHANNEL DEVICE-
INITIATED PACING
DATA
DATA
Channel
DataTalker
Device
Channel
Device
DataTalker
Flow control stops the input
of data to the DataTalker
Pacing stops the output of
data from the DataTalker
1.4.5
Parameter Memory
A nonvolatile memory for storing configurations and options means that the DataTalker remains
configured until you change it. You can configure a DataTalker and save the parameters to
memory, turn it off, ship it, and use it without having to reconfigure it.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1 - Introduction and Description
1.4.6
Diagnostics
Diagnostics in a network are of considerable importance. That is why the DataTalker is equipped
with several diagnostic modes that will test every aspect of the network. The diagnostics include
easy-to-execute tests for the data channel, voice/fax channel, composite link, and various
components of the DataTalker unit itself. The diagnostic tests are executed from a single
diagnostic tests menu by selecting the test number and following any corresponding instructions
given by the DataTalker.
1.4.7
Operational Statistics
Operational statistics provide an activity report of the DataTalker network. Statistics such as
receive-block errors pinpoint composite link device or line problems. Composite link statistics are
displayed in a single screen.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
1.5 FCC Regulations for Telephone Line Interconnection
1. This equipment complies with Part 68 of the FCC rules. On the outside surface of this
equipment is a label that contains, among other information, the FCC registration number
and ringer equivalence number (REN). If requested, this information must be provided to the
telephone company.
2. As indicated below the suitable jack (USOC connecting arrangement) for this equipment is
shown. If applicable, the facility interface codes (FIC) and service order codes (SOC) are
shown.
3. The ringer equivalence number (REN) is used to determine the quantity of devices which
may be connected to the telephone line. Excessive RENs on the telephone line may result in
the devices not ringing in response to an incoming call. In most, but not all areas, the sum of
the RENs should not exceed five (5.0). To be certain of the number of devices that may be
connected to the line, as determined by the total RENs, contact the telephone company to
determine the maximum REN for the calling area.
4. If this equipment causes harm to the telephone network, the telephone company will notify
you in advance. But if advance notice isn’t practical, the telephone company will notify the
customer as soon as possible. Also, you will be advised of your right to file a complaint with
the FCC if you believe it is necessary.
5. The telephone company may make changes in its facilities, equipment, operations, or
procedures that could affect the operation of the equipment. If this happens, the telephone
company will provide advance notice in order for you to make necessary modifications in
order to maintain uninterrupted service.
6. If trouble is experienced with this equipment (the model of which is indicated below) please
contact Multi-Tech Systems, Inc. at the address shown below for details of how to have
repairs made. If the trouble is causing harm to the telephone network, the telephone
company may request you remove the equipment from the network until the problem is
resolved.
7. No repairs are to be made by you. Repairs are to be made only by Multi-Tech Systems or its
licensees. Unauthorized repairs void registration and warranty.
8. This equipment cannot be used on public coin service provided by the telephone company.
Connection to Party Line Service is subject to state tariffs. (Contact the state public utility
commission, public service commission or corporation commission for information.)
9. If so required, this equipment is hearing aid compatible.
Manufacturer:
Model Number:
FCC Registration Number:
Multi-Tech Systems, Inc.
DT10x and DT10xR Series
AU7USA-22313-DE-N (DSU)
AU7USA-22271-MM-E (Modem)
0.3B (Modem)
Ringer Equivalence:
Modular Jack (USOC):
Service Center in U.S.A.
RJ-11 or RJ-48 (single line)
Multi-Tech Systems Inc.
2205 Woodale Drive
Mounds View, MN 55112 USA
(612) 785-3500 or (800) 328-9717
Fax (612) 785-9874
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1 - Introduction and Description
1.6 Canadian Limitations Notice
Notice: The Canadian Department of Communications label identifies certificated equipment. This
certification means that the equipment meets certain telecommunications network protective,
operational and safety requirements. The department does not guarantee the equipment will
operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the
facilities of the local telecommunications company. The equipment must also be installed using
an acceptable method of connection. In some cases, the company’s inside wiring associated with
a single line individual service may be extended by means of a certified connector assembly
(telephone extension cord). The customer should be aware that compliance with the above
conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian facility designated by
the Supplier. Any repairs or alterations made by the user to this equipment; or equipment
malfunctions, may give the telecommunications company cause to request the user to disconnect
the equipment.
Users should insure for their own protection that the electrical ground connections of the power
utility, telephone lines and internal metallic water pipe system, if present, are connected together.
This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading.
The termination on a loop may consist of any combinations of devices subject only to the
requirement that the total of the Load Numbers of all the devices does not exceed 100.
The load number for the composite link modem is 4.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
1.7 Specifications
1.7.1
Async Data Channel
Number of Channels
Maximum Speed
Channel Speed
Data Format
Parity
One
115,200 bps
All standard speeds from 300 bps to 115,200 bps
5, 6, 7, or 8 data bits, with 1, 1.5, or 2 stop bits
Odd, even, or none
Local Echo
On or off selectable
Flow Control
Pacing
XON/XOFF, CTS, or HP ENQ/ACK selectable
On or off selectable, RTS on/off, or XON/XOFF
RS-232D/ITU-T V.24; DB-25 female connector
Interface
1.7.2
Sync Data Channel
Data Format
Channel Speed
Protocol
Synchronous
Up to 128K bps
SDLC/HDLC
Error Correction
Interface
16-bit CRC block check with ARQ
RS-232D/ITU-T V.24; DB-25 female connector
1.7.3
System Control (Command Port)
Local Access
Device
Through DataTalker’s RS232C command port
Any asynchronous keyboard terminal or PC in terminal mode (local
access only)
Menus
Menus to configure data channel, voice/fax channel(s), and
composite link. Statistics menu and test menus are provided to
monitor performance and diagnose problems.
Diagnostics
Data or voice loopback, memory, watch dog tests, and DIP switch
definitions and settings
1.7.4
Composite Link
Number of Links
Data Format
Link Speeds
Link Protocol
Error Correction
Interface
One
Synchronous
Up to 256K bps
Proprietary modified HDLC
16-bit CRC block check with ARQ
RS-232D/V.24 or ITU-T V.35, or use DataTalker integral modem,
DSU, or ISDN terminal adapter
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1 - Introduction and Description
1.7.5
Internal Modem
Modulation
ITU-T V.34; AT&T V.32 terbo; ITU-T V.32bis, V.32, V.22bis, V.22; Bell
212A and 103 (North America) or V.23 and V.21 (international)
Speeds
300 bps to 33.6K bps
Commands
Usage
Fully AT command compatible
Synchronous full duplex over unconditioned 2-wire or 4-wire leased
line; asynchronous half or full duplex over 2-wire dial-up
Line Interface
RJ-11C jack for dial-up and 2-wire or 4-wire leased line; in Canada,
one CA02B connector
1.7.6
Internal DSU
Speed
Format
Usage
56K, 19.2K, 9.6K, 4.8K, or 2.4K bps
Synchronous DDS or compatible
Full duplex over LADS (Local Area Data Set) or two-pair non-loaded
metallic wire
Line Interface
DDS interface with an RJ-48 keyed jack
1.7.7
ISDN Terminal Adapter
Description
Integral ISDN terminal adapter card
ISDN Basic Rate; 1B+D or 2B+D
Operating Mode
Synchronous Data Rates 2.4–128 Kbps
Clocking
Normal network clock (slaved to network receive clock); private
network master (internal); external clock of DTE data
Commands
Menu system
D-Channel Switch
Compatibility
AT&T 5ESS®, 5E6; NT DMS-100™, BCS-32;
Siemens Stromberg-Carlson EWSD®, National ISDN-1;NEC
International Switch
Line Interface
2-wire ISDN Basic Rate 2B1Q U-interface; ANSI T1.601-1992
compliant; RJ-48 jack
B-ChannelAggregation
BONDING Protocol, Mode 1
1.7.8
Voice/Fax Channel
Number of Channels
Voice Digitization Rates
Automatic Fax
One or two channels
9600 and 16K bps
Group 3 fax rates
Modulation/Demodulation (2400, 4800, 7200 and 9600 bps)
Analog Interfaces
Signaling
FXS, FXO, and E&M (channel 1 only)
DTMF
Line Interface
FXS and FXO: RJ-11 jacks
E&M: RJ-48 jack
17
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
1.7.9
Electrical/Physical
Desktop Models:
Power Supply Input
Power Supply Output
Power Consumption
Dimensions
100 to 250 VAC
+5v@5A, +12v@1A, [email protected]
20 watts
2.3" high x 9" wide x 12.8" deep
5.7 cm high x 22.9 cm wide x 32.7 cm deep
Weight
7 pounds (3.2 kg)
Rack-mount Models:
Power Supply Input
Frequency
100 to 250 VAC
47 to 63 Hz
20 watts
Power Consumption
Dimensions
2.00" high x 9. 98" wide x 12.75" deep
5.1 cm high x 25.2 cm wide x 32.4 cm deep
Weight
5 pounds (2.3 kg)
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
2.1 Introduction
The Multi-Tech DataTalker is available in both desktop (DT10x) and rack-mount (DT10xR)
versions. The desktop version is designed for home office applications. It is mounted in a
horizontal cabinet and has an external power supply, a power switch, an originate switch, and a
switch that allows you to use it also as a stand-alone modem or terminal adapter. The rack-mount
version is designed for main office applications. It is mounted for vertical insertion into a Multi-
Tech RackTalker rack, has an internal power supply, is hot-swappable, and has a reset switch.
Otherwise, they are identical. DataTalkers are available with a synchronous or asynchronous
data channel, one or two voice/fax channels, and an optional internal composite link V.34
modem, 56K bps DSU, or 2B+D link ISDN terminal adapter.
DataTalker Configurations
Desktop Models:
1 Da ta Cha nne l & 1
Voic e / Fa x Cha nne l
1 Da ta Cha nne l & 2
Voic e / Fa x Cha nne ls
Ba se Mod e l with...
No Additional Options
Installed
DT101
DT101/V34
DT101/56
DT101/IS
DT102
DT102/V34
DT102/56
DT102/IS
33.6K bps Modem
56K bps DSU
2B+D ISDN Terminal
Adapter
Rack-Mount Models:
1 Da ta Cha nne l & 1
Voic e / Fa x Cha nne l
1 Da ta Cha nne l & 2
Voic e / Fa x Cha nne ls
Ba se Mod e l with...
No Additional Options
Installed
DT101R
DT101R/V34
DT101R/56
DT101R/IS
DT102R
DT102R/V34
DT102R/56
DT102R/IS
33.6K bps Modem
56K bps DSU
2B+D ISDN Terminal
Adapter
Valid Voice/Fax Configurations:
Configuration
Description
E&M to E&M
Any phone or fax machine connected to the PBX at one site can call
any phone or fax machine connected to the PBX at the other end.
FXS to FXS
FXS to FXO
No number must be dialed. If the phone or fax machine on one end
goes off hook, the phone or fax machine on the other end rings.
The phone and fax machine at the FXS site act as though they are
extensions of the PBX at the FXO site.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
2.2 Configuration 1 - Dial-Up Link
Configuration 1 is a dial-up link using a pair of DataTalkers to provide data communications
between a home office PC and the main office host computer and telephone services through the
main office telephone system. The data and telephone services are provided using a single line
between the home office and the main office. In this application, the main office DataTalker is tied
to a host computer via an async channel, and the data channel of the home office DataTalker is
connected to the serial port of the home office PC. The composite link is provided by internal
33.6K modems in a dial-up configuration. All of the telephone services of the main office are
supplied to the home office as if the home office was directly connected to the main office
telephone system.
Asynchronous
Channel
Composite Link
Asynchronous
Channel
PSTN
Data
RXT FCR
/
V
oice
/
Fax Contrator
VOICE
AX
/
/
FXS
FXS
FXO E&M
FXO E&M
F
A
X
XMT RCV XSG RSG
XMT RCV XSG RSG
R
D
T
M
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
F
2
COMPOSITE
LINK
STATUS
DA
T
A/
VOICE
AX
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
COMMAND
F
1
1
M
D
M
/
T
A
Data
RXT FCR
/
V
oice
/
Fax Concentrator
VOICE
AX
/
/
FXS
FXS
FXO E&M
FXO E&M
F
A
X
XMT RCV XSG RSG
XMT RCV XSG RSG
R
D
T
M
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
F
2
COMPOSITE
LINK
Voice/Fax
Channel
STATUS
DA
T
A/
VOICE
AX
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
COMMAND
F
1
1
0
1
M
D
M
/
T
A
DataTalker
DataTalker
PC
Trunk
Voice/Fax
Channel
PSTN
Trunk
Trunk
Station
Station
Telephone
Telephone
PBX
Home Office
Figure 2-1 Dial-Up Link
To set up this configuration, connect the main office DataTalker to the host computer, to the in-
office telephone system (PBX), and to the public switched telephone network (PSTN). Connect
the home office DataTalker to the serial port of your PC, to a telephone set, and to your local
telephone line. You must also connect a terminal or a PC running communications software (such
as Multi-Tech’s MultiExpress™ for DOS) to the dual function data/command port and configure
the DataTalkers. Configure the DataTalker for the main office application; i.e., set up the voice/fax
channel for a local interface of FXO and a remote interface of FXS. Configure the home office
unit for DTR dialing of the main office DataTalker, a local interface of FXS, and a remote interface
of FXO.
You must configure the DataTalkers before you connect them to the computers. To configure a
DataTalker, place DIP switch position 3 in the down (closed) position and connect a command
port device such as a terminal or a PC to the DATA/COMMAND connector on the back of the
DataTalker. Turn on the DataTalker and PC and run your communications software in terminal
mode. (Set it for direct connection at a serial port speed of 19,200 bps or slower.) Press the
ENTER key to establish communications with DataTalker and see the Main Menu.
A series of configuration menus provides simple and complete configuration information for each
aspect of the DataTalker. Using the menus, we will configure one DataTalker for the main office
and the second one for the home office.
The menus flow from the Main Menu through the Configurations menu to configuration menus for
specific parts of the DataTalker. From the Configurations menu you will use the first menu to
configure the data port of the main office unit to talk to the host computer, and that of the home
office unit to talk to the async channel of the home office PC. You will use the next one to
configure the voice/fax channel for connection of the main office DataTalker to an extension of
the local PBX, and the home office DataTalker to your telephone and your local telephone
service. You will use the final group of configuration menus to set up the internal MMH2834
modem to dial the main office from the home office and for the main office to answer the call.
As you go through these configuration menus, you must supply the specifics of your
configuration.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
When you established communication, the Main Menu appeared. From the Main Menu you can
configure the unit, display statistics, reset various functions within the DataTalker, and run
diagnostic tests:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
To configure the DataTalker, enter 1 and press ENTER.
The Configurations menu is displayed. From this menu you can configure the data port, voice/fax
channel(s), or the composite link. You can also select various factory defaults and store your
current configuration:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
For the main office and the home office units, let’s use the default data port configuration. If your
specific configuration requires that the data port be set up differently, select the option and
choose the new parameter.
From the Configurations menu, select option 2, Voice/Fax Channel(s) Configuration, to configure
the voice/fax channels. For the main office, set up the local interface type (option 6) for an FXO
connection. For the remote interface type (option 11), accept the default FXS connection. For the
other selections, accept the defaults .
Voice/Fax Channel 1 Configuration
1 - Destination Channel
2 - Digitizing Rate
3 - Output Level Atten.
4 - Input Level Gain
5 - Silence Suppression
6 - Local Interface Type
: 1
: 9600
: 12
: 03
: Off
: FXS
7 -
8 -
9 -
10 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
Dialtone/Wink (E&M)
Wink Timer (E&M)
: N/A
: N/A
: N/A
: FXS
11 - Remote Interface Type
12 -
13 -
14 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M) : N/A
Dialtone/Wink (E&M) : N/A
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
Enter S and press ENTER to store all configurations for the main office.
Set up the home office unit the same way, except that you should switch the local and remote
interface types (FXS for the local interface and FXO for the remote interface). After you select the
home office options, enter S to store all configurations. Enter P to return to the Configurations
menu.
At the Configurations menu, select option 3, Composite Link Configuration. The composite link
settings for the MMH2834 internal modem are displayed.
The main office will be set up to receive a call from the home office. The home office will be set
up for DTR Dialing of the phone number at the main office.
Composite Link Settings - Internal MMH2834
1
- Enter AT commands to 2834
2 - On-Line XMT Rate:
3 - Speed Setting:
28800
33600
Dial
4
-
Dial/Leased:
5 - 2 or 4 Wire:
6 - Answer/Originate:
7 - Transmit Level
8 - DOD/DOI:
2 Wire
Answer
-10db
On
03min
40sec
9 - DOI Timer:
10 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
Set up the main office unit to use the default composite link settings. Set up the home office unit
for DTR dialing. To set up for DTR dialing, select option 1, Enter AT Commands to 2834, and
enter the following AT commands:
ATDT[Number to Dial]N0 <CR>
AT$D1 <CR>
AT&W <CR>
Q <CR>
ATDT[Number to Dial]N0 is the AT command to store the main office phone number in location
N0. The AT$D1 command sets the modem for DTR dialing when the home office DataTalker is
powered up. The AT&W stores the $D1 command as a user default. The Q command returns you
to the Composite Link Settings menu. <CR> is shorthand for a carriage return (press ENTER).
Enter S and press ENTER to store the new configuration.
This completes the configuration of both DataTalkers. The main office DataTalker can now be
connected to the host computer, PBX, and phone line. The home office DataTalker can be taken
home.
To connect the main office DataTalker, first disconnect the PC or terminal from the DATA/
COMMAND connector on the DataTalker. Place DIP switch position 3 in the OPEN (up) position
to change the data/command port over to the data channel. Connect an RS232C cable between
the DATA/COMMAND connector on the DataTalker and an asynchronous port on the host
computer. Connect an RJ-11 phone cable from the VOICE/FAX CHANNEL 1 FXO connector on
the back panel to the station side of the PBX. Connect an RJ-11 phone cable between the DIAL-
UP jack on the DataTalker and the dial-up phone line.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
To connect the home office DataTalker to its PC, connect an RS232C cable between the DATA/
COMMAND connector on the DataTalker and an async port on the PC (typically, COM1 or
COM2). Place DIP switch position 3 on the side of the DataTalker in the OPEN (up) position to
enable the data channel.
To connect your home telephone to the DataTalker, remove the telephone cable from the wall
jack and connect it to the VOICE/FAX CHANNEL 1 FXS connector on the DataTalker. Connect a
second RJ-11 phone cable between the Dial-Up jack on the DataTalker and your wall jack.
The home office DataTalker is now ready to communicate with the main office. When you power
on the home office DataTalker, the internal MMH2834 modem dials the previously stored number
for the main office. The OH (Off-Hook) LED lights, indicating that the modem is active. After the
main office DataTalker answers, the CD (Carrier Detect) LED lights and the RD (Remote Down)
LED goes off. At this point, voice and data communication can begin.
If you do not configure the DataTalker for DTR dialing, there is an alternate way to dial the main
office computer. Connect a phone to the FXS jack and a dial-up phone line to the internal
composite link DIAL-UP jack. Pick up the receiver and listen for a dial tone, then dial the main
office number. When you hear the answer tone, press and release the Originate switch on the
DataTalker’s front panel. The OH light will come on, then the modem will handshake and connect.
Hang up the phone and data communications will proceed normally.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
2.3 Configuration 2 - MMH900 Series with Voice/Fax
Configuration 2 adds voice capability to an existing data-only network using the same composite
link. The example shown in Figure 2-2 had an existing data-only network consisting of a MultiMux
MMH904C multiplexer connected to a host computer at the local site and a second MMH904C
connected to terminals and/or PCs and a shared printer at the remote site. To add voice
capability, a DataTalker is added between the composite link of the MMH904 and the public data
network (PDN) at both sites. The composite link between the two sites is now moved from the
MMH904 multiplexer to the new DataTalker. The composite link of the MultiMux MMH904 is
reconfigured as an external synchronous link device and connected to the synchronous data
channel of the DataTalker. The voice capability is added by connecting a telephone to the FXS
port on the back panel of the DataTalker at each site and configuring the voice/fax channel of the
DataTalkers for FXS to FXS. Now, while you are transferring data over the composite link, you
can pick up the telephone and have a simultaneous voice conversation.
Asynchronous
Channel
Sync Data
Channel
Asynchronous
Channel
Sync Data
Channel
Composite Link
PDN
R
E
BUFFER
FULLNESS
LEVEL
FL
O
L
RE
M
T
ES
AS
Y
N
C
I
N
T
E
R
N
(
A
M
L
o
L
d
I
e
M
N
m
K
s
D
)
E
V
I
C
E
I
T
NK
T
5
V
2
9
/
V
3
MultiTech
R
A
N
S
M
IT
R
R
V
A
A
M
E
T
K
Systems
M
O
D
E
L
I
N
K
D
SU
8
3
4
Command Modem
RCV XMT OH
DTR
Channel Five
RCV XMT
Channel Six
RCV XMT
Channel Seven Channel Eight
RCV XMT RCV XMT
1
2
3
C
R
W
D
N
CD
MultiMux
RE
T
R
A
N
S
M
IT
BUFFER
FUL SS
LEVEL
L
L
I
RE
ET AS
ST YN
C
I
N
T
E
R
N
(
A
M
L
o
L
d
I
e
M
M
H
2
N
m
K
s
D
)
E
V
I
C
E
L
NE
OC
NK
MO
T
5
6
V
MultiTech
Systems
R
R
V
A
A
M
E
2
9
/
External Composite Link
CD RCV XMT CTS
.35
Channel one
RCV XMT
Channel
Two Channel Three Channel Four
RCV XMT RCV XMT
I
n
t
e
r
n
a
l
C
2
o
m
p
4
o
s
i
t
e
L
i
n
k
Statistical Multiplexer
M
O
D
L
I
D
S
U
V
3
8
V
R
C
V
X
M
T
C
o
m
m
a
n
d
M
o
d
e
m
Channel Five
RCV XMT
Channel Six
RCV XMT
Channel Seven Channel Eight
RCV XMT RCV XMT
1
2
3
C
R
W
D
N
E
NK
34
M
M
H
2
8
3
4
C
D
R
C
V
X
M
T
C
T
S
2
8
5
.
8
6
2
1
4
9
.
.
0
2
1
R
9
T
.
1
4
.
O
H
T
T
R
M
E
C
D
B
U
P
CD
RCV
XMT
OH
DTR
D
S
U
C
D
R
C
V
X
M
M
T
C
TS
S
S
N
S
O
O
S
MultiMux
Statistical Multiplexer
V
2
9
/
V
3
3
M
o
d
e
m
C
D
R
C
V
X
T
C
T
External Composite Link
CD RCV XMT CTS
.35
Channel one
RCV XMT
Channel
T
w
o
C
h
a
n
n
e
l
T
h
r
e
e
C
h
a
n
n
e
l
F
o
u
r
I
n
t
e
r
n
a
l
C
2
o
m
p
4
o
s
i
t
e
L
i
n
k
V
R
C
V
X
M
T
R
C
V
X
M
T
R
C
V
X
M
T
M
M
H
2
8
3
4
C
D
R
C
V
X
M
T
C
T
S
2
8
5
.
8
2
1
4
9
.
.
0
2
1
R
9
.
1
4
.
O
H
T
T
R
M
E
C
D
B
U
P
D
S
U
C
D
R
C
V
X
M
M
T
C
TS
S
6
T
S
N
S
O
O
S
V
2
9
/
V
3
3
M
o
d
e
m
C
D
R
C
V
X
T
C
T
MultiMux MMH904
MultiMux MMH904
Data
RXT FCR
/
V
oice
/
Fax Concentrator
VOICE
AX
/
/
FXS
FXS
FXO E&M
FXO E&M
F
A
X
XMT RCV XSG RSG
XMT RCV XSG RSG
R
D
T
M
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
F
2
COMPOSITE
LINK
STATUS
DA
T
A/
VOICE
AX
C
O
M
M
A
N
D
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
F
1
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
1
0
1
M
D
M
/
T
A
Data
RXT FCR
/
V
oice
/
Fax Concentrator
VOICE
AX
/
/
FXS
FXS
FXO E&M
FXO E&M
F
A
X
XMT RCV XSG RSG
XMT RCV XSG RSG
R
D
T
M
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
F
2
COMPOSITE
LINK
STATUS
Voice/Fax
Channel
DA
T
A/
VOICE
AX
C
O
M
M
A
N
D
X
M
T
R
C
V
FC
C
O
M
R
I
G
F
1
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
1
0
1
M
D
M
/
T
A
Voice/Fax
Channel
DataTalker
DataTalker
Telephone
Telephone
Local Site
Printer
Remote Site
Figure 2-2. Adding Voice to Data-Only Network
The async channels of the MultiMux MMH904s operate the same way as in the data-only
network. The MMH904 is reconfigured for an external link device by changing the 8-position DIP
switch position 2 to the down (closed) position, ensuring that the composite link is configured for
sync mode, and setting clocking to External. An RS232C cable can now be connected to the
COMPOSITE LINK EXTERNAL RS232C/V.35 connector on the back panel of the MMH904.
The composite link connection of the DataTalker to the PDN depends on the type of link device
being used. If the link device is an internal 33.6K bps modem, connect the Modem DIAL-UP or
LEASED connector to the PDN. If the link device is an internal DSU or ISDN terminal adapter,
connect the DSU/TA DIGITAL connector to the PDN. If an external link device is used, cable it to
the EXTERNAL COMPOSITE RS232C/V.35 connector. The connection type depends on whether
the interface of the external link device is RS232C or V.35. If it is V.35, a shunt on the main board
of the DataTalker must be moved to the V.35 position.
You must configure the DataTalker before you connect it to the MultiMux MMH904. To configure
the DataTalker, place DIP switch position 3 in the down (closed) position and connect a command
port device such as a terminal or a PC to the DATA/COMMAND connector on the back of the
DataTalker. Turn on the DataTalker and PC and run your communications software in terminal
mode. (Set it for direct connection at a serial port speed of 19,200 bps or slower.) Press the
ENTER key to establish communications with DataTalkerand see the Main Menu.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
A series of configuration menus provides simple and complete configuration information for each
aspect of the DataTalker. From the Main Menu, you can access menus to configure the unit,
display statistics, reset various functions within the DataTalker, and run diagnostic tests:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
To go to the Configurations menu, enter 1 and press ENTER. The Configurations menu appears.
From this menu you can configure the data port, voice/fax channel(s), or the composite link. This
menu also allows you to select various factory defaults and store your current configuration.
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
For configuration 2, start by configuring the data port. Enter 1 and press ENTER. The Data Port
Configuration menu appears:
Data Port Configuration
1
2
3
4
5
6
7
8
9
- Async/Sync:
- Speed:
- Word Length:
- Stop Bits:
- Parity:
Async
19200
8
1
None
CTS
Off
Off
Off
Off
Off
- Flow Control:
- Enq/Ack Flow Control:
- Echo:
- Pacing:
10 - EIA Pass Through:
11 - Pass Xon:
S
M
P
- Store All Configurations
- Main Menu
- Previous Menu
Selection : _
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
The data port in this configuration will be set up for synchronous operation. To configure the data
port for sync operation, enter 1 (Aysnc/Sync) option and change the default Async to Sync. The
data port configuration menu displays the sync parameters.
Data Port Configuration
1 - Async/Sync:
2 - Speed:
Sync
19200
Internal
Flags
NRZ
3 - Clocking:
4 - Idle Condition:
5 - NRZ/NRZI Encoding:
6 - CRC Preset:
7 - Inter-frame Timer:
S - Store All Configuations
M - Main Menu
P - Previous Menu
Selection : _
All 1s
Off
Enter 2 and press ENTER to set the speed of the sync data port. Select the appropriate speed
by entering its menu list number. The speed you select should be no faster than the composite
link speed. At the sync data port configuration menu, determine who is supplying the clocking.
The default internal clocking allows the DataTalker to supply the clock. Enter the letter S to store
all configurations and then press P to return to the previous menu.
For configuration 2, where both sites have a telephone connected to the DataTalker, initially
accept the defaults for the second choice in the Configurations menu, Voice/Fax Channels
Configuration.
At the Configurations menu, enter 3 and press ENTER to display the Composite Link Settings
menu.
The DataTalker detects the type of link device being used from the way a DIP switch is set or by
reading the device when it is installed on the main PC board. In this configuration, a 56K bps
internal DSU is being used as the composite link device. So, when the internal composite link
settings menu is displayed, it is for a DSU:
Composite Link Settings - Internal DSU
1 - Speed:
56k
DDS
2 - Clocking:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The internal DSU has two options: speed and clocking. The speed option should match the DDS
line speed. The clocking option depends on how you have set up your link with the telephone
company. If the link is set up as a DDS link, use the default DDS setting. If the link is set up for
the DataTalker to provide the clocking, change the clocking option to Internal.
This completes the configuration of both DataTalkers. Disconnect the data/command port from
the terminal or PC and connect it to the composite link of the MMH904. Place DIP switch position
3 on both DataTalkers in the up (OPEN) position to change the data/command port over to a data
channel.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
2.4 Configuration 3 - LAN to LAN
Configuration 3 is an example of a pair of DataTalkers providing the link between two LANs with
the added benefit of voice or fax traffic over the same composite link. Bridging the LANs over a
single high speed composite link expands the capacity of each LAN. The LAN bridge on each
LAN is provided by a router/bridge with a synchronous interface connected to the DataTalker’s
data channel. The composite link could be an internal ISDN terminal adapter, an internal 56K
DSU, or one of a variety of external high speed link devices up to fractional T1 devices. The
additional feature provided by the DataTalkers is free voice or fax traffic without the need to
establish a separate voice connection between the two LANs.
Ethernet
Concentrator
Ethernet
Concentrator
Communications
Server
LAN PC
LAN PC
LAN PC
Sync Data
Channel
Sync Data
Channel
Composite Link
PDN
File Server
®
T
ech
Systems
®
T
ech
Systems
LAN PC
LAN PC
Router/Bridge
Router/Bridge
Data
RXT FCR
/
i
/
Cncentrator
VOICE
AX
/
/
FXS
FXS
FXO E&M
FXO E&M
F
AX
XMT RCV XSG RSG
XMT RCV XSG RSG
R
D
T
M
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
F
2
COMPOSITE
LINK
STATUS
DA
T
A/
VOICE
AX
C
O
M
M
A
N
D
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
F
1
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
0
M
D
M
/
T
A
Data
RXT FCR
/
V
oice
/
Fax Concentrator
VOICE
AX
/
/
FXS
FXS
FXO E&M
FXO E&M
F
A
X
XMT RCV XSG RSG
XMT RCV XSG RSG
R
D
T
M
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
F
2
COMPOSITE
LINK
STATUS
DA
T
A/
VOICE
AX
C
O
M
M
A
N
D
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
F
1
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
1
0
1
M
D
M
/
T
A
DataTalker
DataTalker
Voice/Fax
Channel
Communications
Server
Printer Print Server
Voice/Fax
Channel
Trunk
Trunk
LAN PC
Trunk
File Server
PSTN
Station
Station
Telephone
PBX
Print Server Printer
Telephone
LAN 2
LAN 1
Figure 2-3. LAN to LAN Configuration
In the configuration shown in Figure 2-3, the voice/fax channel 1 FXO port on the DataTalker at
LAN 1 is connected to a station card on the local PBX, and the voice/fax channel 1 FXS port on
the DataTalker at LAN 2 is connected to a telephone. On both ends, the data channel of the
DataTalker is connected to the router’s synchronous port, and the router’s Ethernet port is
connected to the Ethernet concentrator. An RJ-48 telephone cable connected to the composite
link at the DataTalker’s DSU/TA DIGITAL connector links the DataTalker’s internal DSU to the
public data network.
You must configure the DataTalkers before you connect them to the LANs. To configure a
DataTalker, place DIP switch position 3 in the down (closed) position and connect a command
port device such as a terminal or a PC to the DATA/COMMAND connector on the back of the
DataTalker. Turn on the DataTalker and PC and run your communications software in terminal
mode. (Set it for direct connection at a serial port speed of 19,200 bps or slower.) Press the
ENTER key to establish communications with DataTalkerand bring up the Main Menu.
A series of configuration menus provides simple and complete configuration information for each
aspect of the DataTalker. From the Main Menu, you can configure the unit, display statistics,
reset various functions within the DataTalker, and run diagnostic tests:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
To configure the DataTalker, enter 1 and press ENTER.
The Configurations menu is displayed. From this menu you can configure the data port, voice/fax
channel(s), or the composite link. You can also select various factory defaults and store your
current configuration:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
For configuration 3, let’s start by configuring the data port. Enter 1 and press ENTER. The Data
Port Configuration menu is displayed:
Data Port Configuration
1
2
3
4
5
6
7
8
9
- Async/Sync:
- Speed:
- Word Length:
- Stop Bits:
- Parity:
Async
19200
8
1
None
CTS
Off
Off
Off
Off
Off
- Flow Control:
- Enq/Ack Flow Control:
- Echo:
- Pacing:
10 - EIA Pass Through:
11 - Pass Xon:
S
M
P
- Store All Configurations
- Main Menu
- Previous Menu
Selection : _
Since the data port in this configuration is going to be set up for synchronous operation, only two
options apply: Clocking and Speed. Enter 1 and press ENTER to change to the synchronous
mode of operation. At the Sync Data Port Configuration menu, select the appropriate speed by
entering its menu list number. Use caution when setting the speed—the sync data channel could
very easily overrun the composite link if the speed is set too high. Enter 2 and press ENTER to
change the clocking to internal, which allows the DataTalker to provide the clock.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Data Port Configuration
1 - Async/Sync:
Sync
2 - Speed:
19200
Internal
Flags
NRZ
3 - Clocking:
4 - Idle Condition:
5 - NRZ/NRZI Encoding:
6 - CRC Preset:
All 1s
Off
7 - Inter-frame Timer:
S - Store All Configuations
M - Main Menu
P - Previous Menu
Selection : _
Press P to return to the Data Port Configuration menu, enter S to store all configurations, and
then press P again to return to the previous menu. At the Configurations menu, enter 2 and press
ENTER.
The Voice/Fax Channel 1 Configuration menu is displayed. For LAN 1, set voice/fax channel 1 for
an FXO connection as the local interface type (option 6), and keep the default FXS as the remote
interface type (option 11). LAN 2 must be set just the opposite (FXS for the local interface and
FXO for the remote interface). For the other selections, accept the defaults .
Voice/Fax Channel 1 Configuration
1 - Destination Channel
2 - Digitizing Rate
3 - Output Level Atten.
4 - Input Level Gain
5 - Silence Suppression
6 - Local Interface Type
: 1
: 9600
: 12
: 03
: Off
: FXS
7 -
8 -
9 -
10 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
Dialtone/Wink (E&M)
Wink Timer (E&M)
: N/A
: N/A
: N/A
: FXS
11 - Remote Interface Type
12 -
13 -
14 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
: N/A
: N/A
Dialtone/Wink (E&M)
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
Enter S and press ENTER to store all configurations for LAN 1.
Set up LAN 2 in the same manner, but switch the local and remote interface types (FXS for the
local interface and FXO for the remote interface). When you have finished selecting the LAN 2
options, enter S to store all configuration. Enter P to return to the Configurations menu.
At the Configurations menu, enter 3 and press ENTER to display the composite link configuration
menu.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
The DataTalker knows the type of link device being used by the way a DIP switch is set or by
detecting a device installed on the main PC board. In this configuration, a 56K bps internal DSU
is used for the composite link device, so when the Composite Link Settings menu is displayed, it
is for a DSU:
Composite Link Settings - Internal DSU
1 - Speed:
56k
DDS
2 - Clocking:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The internal DSU has three options: speed and clocking. The speed option should match the
DDS line speed. The clocking option depends on how you have set up your link with the
telephone company. If the link is set up as a DDS link, use the default DDS setting. If the link is
set up for the DataTalker to provide the clocking, change the clocking option to Internal. Enter S
and press ENTER to store all configurations.
If you are setting up the composite link for an external composite link device, set up the device
for internal clocking and the type of connection between the device and the DataTalker, i.e., an
RS232 or a V.35 connection.
Composite Link Settings -External Device
1 - On-Line XMT Rate:
2 - Clocking:
56000
External
Off
3 - Back to Back:
4 - DOD/DOI:
On
5 - DOI Timer:
03min
40sec
6 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
When you select option 3 in the Configurations menu, the Composite Link Settings - External
Device menu will be displayed. Set the clocking and speed options to match the external device.
The back to back option should remain off. Enter S and press ENTER to store all configurations.
This completes the configuration of both DataTalkers. Disconnect the data/command port from
the terminal or PC and connect it to the router. Place DIP switch position 3 on both DataTalkers in
the up (OPEN) position to change the data/command port over to a data channel.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
2.5 Configuration 4 - PBX to PBX
Configuration 4 is a data/voice/fax configuration that uses two DataTalkers to link two PBXs.
Using a single ISDN composite link, they connect a minicomputer and a PBX E&M trunk at the
local site to a remote PC on the data part of the network and a second PBX E&M trunk on the
voice/fax channel. The configuration is shown in Figure 2-4.
Asynchronous
Channel
Asynchronous
Channel
ISDN
Dat
a
/
Voic
e
/
Fax Concentrator
Dat
a
/
Voic
e
/
Fax Concentrator
VOICE
AX
/
/
VOICE
AX
/
/
F
2
FXS
FXS
FXO E&M
FXO E&M
F
A
X
XMT RCV XSG RSG
XMT RCV XSG RSG
RXT
FCR
RD
TM
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
FXS
FXS
FXO E&M
FXO E&M
F
A
X
XMT RCV XSG RSG
XMT RCV XSG RSG
RXT
FCR
RD
TM
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
T
A
COMPOSITE
LINK
F
2
COMPOSITE
LINK
STATUS
S
T
A
T
U
S
DA
T
A/
VOICE
AX
DA
T
A/
VOICE
AX
OMMAND
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
F
1
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
C
O
M
M
A
N
D
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
F
1
F
A
X
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
1
0
1
M
D
M
/
T
A
1
0
1
M
D
M
/
T
A
Composite Link
DataTalker
DataTalker
PC
Voice/Fax
Channel 1 E&M
Minicomputer
Voice/Fax
Channel 1 E&M
Trunk
Trunk
Trunk
Trunk
PSTN
PSTN
Trunk
Trunk
Station
Station
Station
Station
Telephone
Telephone
PBX
PBX
Remote Site
Figure 2-4. PBX to PBX Configuration
Local Site
At both the local and the remote sites, connect the DATA/COMMAND connector on the
DataTalker to an asynchronous port on the computer; connect the DSU/TA DIGITAL jack on the
DataTalker to the jack for the ISDN service; and connect the VOICE/FAX CHANNEL 1 E&M jack
on the DataTalker to a PBX E&M trunk connector. When you are making an E&M connection,
you should also run a ground wire from the ground connector on back of the DataTalker or the
RackTalker rack to a ground connection on the PBX.
Before you install the DataTalkers, you must configure them. To configure a DataTalker, place
DIP switch position 3 in the down (closed) position and connect a command port device such as
a terminal or a PC to the DATA/COMMAND connector on the back of the DataTalker. Turn on the
DataTalker and PC and run your communications software in terminal mode. (Set it for direct
connection at a serial port speed of 19,200 bps or slower.) Press the ENTER key to establish
communications with DataTalker. The Main Menu will appear.
The Main Menu provides access to a series of configuration menus providing simple and
complete configuration information for each aspect of the DataTalker. From the Main Menu, you
can configure the unit, display statistics, reset various functions within the MMV, and run
diagnostic tests:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
To configure the DataTalker, enter 1 and press ENTER.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2 - Configuration
The Configurations menu is displayed. From this menu you can configure the data port, voice/fax
channel(s), or the composite link. You can also select various factory defaults and store your
current configuration.
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
For both the local and the remote DataTalkers, the data communications will be asynchronous,
so you may accept the defaults in the Data Port Configuration menu (option 1). If your
configuration requires you to set up the data ports differently, enter 1 and press ENTER to select
the Data Port Configuration menu, and select the new parameters.
To configure the voice/fax channels, enter 2 and press ENTER. The Voice/Fax Channel 1
Configuration menu appears. For both DataTalkers, change the local interface type (option 6) and
the remote interface type (option 11) to E&M . For the other selections, accept the defaults .
Voice/Fax Channel 1 Configuration
1 - Destination Channel
2 - Digitizing Rate
3 - Output Level Atten.
4 - Input Level Gain
5 - Silence Suppression
6 - Local Interface Type
: 1
: 9600
: 12
: 03
: Off
: FXS
7 -
8 -
9 -
10 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
Dialtone/Wink (E&M)
Wink Timer (E&M)
: N/A
: N/A
: N/A
: FXS
11 - Remote Interface Type
12 -
13 -
14 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
: N/A
: N/A
Dialtone/Wink (E&M)
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
Enter S and press ENTER to store your selections. Enter P to return to the Configurations menu.
At the Configurations menu, enter 3 and press ENTER to display the Composite Link Settings
menu.
The DataTalker knows the type of link device being used by the way a DIP switch is set or by
reading an installed device on the main PC board. In this configuration, an internal ISDN terminal
adapter is being used as the composite link device. So, when the Composite Link Settings menu
is displayed, it is for an internal terminal adapter:
33
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Composite Link Settings - Internal TA
1 - On-Line XMT Rate:
128000
Off
2 - Configure TA
3 - DOD/DOI:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The terminal adapter menu displays the transmit rate and option 2 allows you to configure the
terminal adapter. Use option 2 (Configure TA) to access the terminal adapter’s built-in
configuration menus (refer to the ISDN Terminal Adapter Owner’s Manual for details). The Flush
Time option is used only with an Alpha microcomputer or Wyse terminal. Enter S and press
ENTER to store all configurations.
This completes the configuration of both DataTalkers. Disconnect the data/command port from
the terminal or PC and connect it to the data computer or PC. Place DIP switch position 3 on
both DataTalkers in the up (OPEN) position to change the data/command port over to a data
channel.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3 - Front and Rear Panel Descriptions
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
3.1 Introduction
This chapter describes the DataTalker front and back panels and switches. The front panel
contains LED indicators for the data channel device, voice/fax channels, and the composite link.
It also contains one or two switches, depending on whether it is a desktop or rack version. The
back panel contains connectors for the data/command device, internal and external composite
link devices, and the voice/fax channel devices. The desktop version also has a power switch.
3.2 Indicators
The DataTalker is equipped with a complete set of LED indicators on the front panel that show
precisely what is occurring on the network at all times. By periodically checking the indicators you
can keep abreast of system activity without tying up the channel device. There are three groups
of indicators: data/command, voice/fax channel, and composite link. Use black legends on dual
function composite link indicators with an internal DSU, blue legends with an internal modem,
and underlined legends, such as TA, with an ISDN terminal adapter. On the desktop DataTalker
the indicators are arranged horizontally, whereas on the rack-mounted DataTalker they are
arranged vertically, but the relative position and function is the same on each. Table 3-1 explains
the function of each indicator by group.
Data / Voice / Fax Concentrator
VOICE
FAX
/
/
FXS
FXS
FXO E&M FAX
FXO E&M FAX
XMT RCV XSG RSG
XMT RCV XSG RSG
RXT
FCR
RD
TM
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
TA
2
COMPOSITE
LINK
STATUS
DATA/
COMMAND
VOICE
FAX
XMT RCV
FC
COM ORIG
CD
RCV XMT CTS
RTS
NS
OOS
2B
1
101 MDM/TA
Figure 3-1. Front Panel (Desktop Version)
Table 3-1. LED Indicators
Data/Command Indicators
XMT (Transmit) This indicator lights when the device connected to the data or command
channel is transmitting data to the DataTalker.
RCV (Receive) This indicator lights when the device connected to the data or command
channel is receiving data from the DataTalker.
FC (Flow Control) This indicator lights when the DataTalker has stopped channel data flow
because the channel buffer is almost full. If the DataTalker stops data flow at the request of a
remote device, the Flow Control Received (FCR) indicator also lights. If the DataTalker stops
data flow for any other reason, the FCR indicator remains off.
Data Flow
Async
Channel
Async
Channel
Composite
Link
Remote
Device
Host
CPU
Host
DataTalker
Remote
DataTalker
FC LED ON
FCR LED ON
FC LED ON
Flow Control
COM (Command) This LED indicates whether the data or the command channel is selected. It
lights when the command channel is selected (DIP switch 3 is down), and is off when the data
channel is selected (DIP switch 3 is up).
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3 - Front and Rear Panel Descriptions
Voice/Fax Channels
FXS (Foreign Exchange Station) This indicator lights when the voice/fax channel is configured
for FXS operation.
FXO (Foreign Exchange Office) This indicator lights when the voice/fax channel is configured
for FXO operation.
E&M (E&M Operation) This indicator lights when the voice/fax channel is configured for E&M
operation (voice/fax channel 1 only).
FAX (Fax) This indicator lights when there is fax traffic on the voice/fax channel.
XMT Transmit. This indicator lights when voice or fax data is being transmitted.
RCV (Receive) This indicator lights when voice or fax data is being received.
XSG (Transmit Signal) This indicator lights when the FXS-configured channel is off-hook, the
FXO-configured channel is receiving a ring from the telco, or the M lead is active when the voice/
fax channel is configured for E&M operation (i.e., the DataTalker is receiving a ring from the
PBX).
RSG (Receive Signal) This indicator lights when the FXS-configured channel is ringing or the E
lead is active on the E&M-configured channel.
Composite Link Status
RXT (Retransmit) This indicator lights when the local DataTalker is retransmitting a block of data
on request. The RXT indicator lights for both internal and external link devices.
FCR (Flow Control Received) This indicator lights when the remote DataTalker’s buffers are full
and the local DataTalker has been told to stop sending data. This indicator lights for both internal
and external link devices.
RD (Remote Down) This indicator lights when the local DataTalker cannot establish
communications with the remote DataTalker. The RD lights for both internal and external link
devices.
TM (Test Mode) This indicator lights when one of the diagnostic tests is active.
V35 (V.35 Interface) This indicator lights when the V.24/V.35 shunt is in the V.35 position.
EXT (External) This indicator lights when the DataTalker is configured for an external composite
link device (DIP switch 2 is down).
MDM (Modem) This indicator lights when the internal composite link device is a modem.
DSU (Data Service Unit) This indicator lights when the internal composite link device is a DSU.
TA (Terminal Adapter) This indicator lights when the internal composite link device is an ISDN
terminal adapter.
CD (Carrier Detect) This indicator lights when the composite link detects a carrier signal from a
remote DataTalker or a local external DSU or modem.
RCV (Receive) This indicator flashes as data is being received from a remote DataTalker. The
RCV indicator flashes for both internal and external link devices.
XMT (Transmit) This indicator flashes as data is being transmitted to the remote DataTalker. The
XMT indicator flashes for both internal and external link devices.
CTS (Clear To Send) This indicator lights when the composite link device is ready to transmit
data. The CTS indicator lights for both internal and external link devices.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
28.8/56 (28.8K bps/56K bps) This composite link speed indicator displays the baud rate of the
internal modem (28.8) or DSU (56K). The type of composite link device is indicated by which of
the EXT, MDM, DSU, or TA indicators lights.
This indicator lights steadily when a DSU is installed. It has three states when an internal
MMH2834 modem is installed (ON, flashing seven or eight times per second). When the LED is
ON solid, it indicates a link speed of 33.6K bps. When the LED flashes eight times with a one
second off time, the link speed is 31.2K and when it flashes seven times with a one second off
time, the link speed is 28.8K bps.
RTS/DTR (Request to Send/Data Terminal Ready) This dual function indicator functions as a
Request To Send (RTS) indicator when a DSU is the internal composite link device or as a Data
Terminal Ready (DTR) indicator when an internal modem or an ISDN terminal adapter is the
composite link device.
NS/DBUP (No Signal/Dial Backup) This dual function indicator functions as a No Signal (NS)
indicator when a DSU is installed. It lights when no signal at all is received from a DDS line or
when the signal is too weak for normal operation. When a 33.6K bps modem is selected as the
composite link device, it functions as a Dial Backup (DBUP) indicator, lighting when the modem is
in dial backup mode.
OOS/OH (Out of Service/Off-Hook) This dual function indicator functions as an Out Of Service
(OOS) indicator when an internal DSU is installed. It lights when an out of service signal is
detected by the telco. When a 33.6K bps modem is selected as the composite link device, it
functions as an off-hook (OH) indicator, lighting when the modem is active (off-hook).
2B (2B Operation) If an ISDN terminal adapter is installed, this indicator lights when the two
ISDN B channels are operating as a single, high-speed, 128K bps channel. The indicator is off
when one B channel is operating.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3 - Front and Rear Panel Descriptions
3.3 Connectors
The cable connections for the DataTalker are made at the back panel. Refer to Chapter 5 for
cabling installation procedures. Refer to Appendix C for cabling diagrams. The DataTalker back
panel is shown in Figure 3-2.
Frame Ground
VOICE/FAX CHANNEL 2
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL 1
POWER
Power Switch
Figure 3-2. Back Panel (Desktop Version)
3.3.1
Frame Ground Connector (GND)
Use the GND connector to connect the DataTalker frame ground to the PBX’s frame ground
when the DataTalker is configured for E&M operation. (The frame ground connector for the rack
version is on back of the RackTalker rack.)
3.3.2
POWER Connector
The POWER connector shown in Figure 3-2 is the receptacle for the DC power module supplied
with the desktop DataTalker. The rack-mounted DataTalker has an AC power connector that
plugs into the power bus on a Multi-Tech RackTalker rack when the DataTalker is inserted.
3.3.3
DATA/COMMAND Connector
Use this female DB-25 connector to connect the DataTalker to a data channel device such as a
terminal, PC, or router, or to configure the DataTalker in command mode. The data channel
device can be synchronous or asynchronous. In command mode, an ASCII terminal or a PC with
a serial port can be used to configure the DataTalker. The connector’s function (data or
command) is determined by the position of DIP switch position 3.
3.3.4
EXTERNAL COMPOSITE RS232C/V.35 Connector
Use this male DB-25 connector to connect to an external modem, DSU, ISDN terminal adapter,
or any device that is synchronous, full duplex, and supplies clocking signals on pins 15 and 17.
The connection interface can be either RS232C or V.35, selected by moving an internal V.35
shunt.
3.3.5
VOICE/FAX CHANNEL 1 FXS Connector
Use the FXS (Foreign eXchange Station) connector to connect the DataTalker to an analog
station instrument (telephone, fax machine, or key telephone system). The FXS connector is an
RJ-11 jack. If a second voice/fax channel is installed, it has an identical connector.
3.3.6
VOICE/FAX CHANNEL 1 FXO Connector
Use the FXO (Foreign eXchange Office) connector to connect the DataTalker to a analog station
card on the local PBX (Private Branch eXchange). This connection is also commonly referred to
as an OPX (Off Premises eXtension). The FXO connector is an RJ-11 jack. If a second voice/fax
channel is installed, it has an identical connector.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
3.3.7
VOICE/FAX CHANNEL 1 E&M Connector
Use the E&M connector to connect the DataTalker to the E&M connector on an analog PBX trunk
when linking two PBXs together. The E&M connector is an RJ-48 jack. This connector is
available on voice/fax channel 1 only.
3.3.8
DSU/TA DIGITAL Connector
Use the DSU/TA Digital connector to connect the DataTalker to a DDS or dedicated network line
when an internal DSU is installed, or to an ISDN line when the ISDN terminal adapter is installed.
The connector is an RJ-48 jack.
3.3.9
MODEM LEASED Connector
Use the LEASED connector to connect the DataTalker to a leased line when an internal
composite link modem is installed. The connector is an RJ-11 jack.
3.3.10 MODEM DIAL-UP Connector
Use the DIAL-UP connector to connect the DataTalker to the PSTN when an internal composite
link modem is installed. The connector is an RJ-11 jack.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3 - Front and Rear Panel Descriptions
3.4 Switches and Shunts
DataTalker switches include one or two switches on the front panel, a power switch on the back
panel of the desktop version, and a DIP switch and shunt on the main printed circuit board
(Figures 3-3 and 3-4).
Power
Switch
RS-232
Shunt
V.35
Shunt
1
2
3
4
5
6
DIP
Switch
101-MDM/TA
Switch
Originate
Switch
Figure 3-3. Switches and Shunts (Desktop Version)
Power
Connector
RS-232
Shunt
V.35
Shunt
1
1
ô
DIP
Switch
M
x
o
/
C
e
t
M
l
D a t a
/
Reset
Switch
Figure 3-4. Switches and Shunts (Rack Version)
3.4.1
Front Panel Switches
ORIG
Originate Mode. Desktop version only. Use this pushbutton to manually dial a
modem or another DataTalker. To use the Originate switch, manually dial the
remote modem’s number on a phone connected to the voice/fax channel 1 FXS
connector on your DataTalker. Listen for the dialed modem’s answer tone. When
you hear it, press and release the Originate switch. Replace the telephone
handset in its cradle, and your data communications can begin.
101-MDM/TA DataTalker or Modem/TA Mode. Desktop version only. Place this slide switch in
the 101 position to use the DataTalker’s standard features. If an internal modem
or ISDN terminal adapter is installed, place it in the MDM/TA position to use the
DataTalker as a stand-alone modem or ISDN terminal adapter (e.g., to call a
BBS or an on-line information service).
RESET
Reset. Rack version only. This is a pushbutton switch located behind a hole on
the front panel. Use it to reset the DataTalker. (Turn the desktop version off and
on again to achieve the same result.) Insert a narrow object such as a pen or
pencil point through the hole to activate it.
3.4.2
Power Switch
The power switch on the back panel of the desktop DataTalker provides DC power when placed
in the I (on) position, and removes power when in the O (off) position. The rack-mounted
DataTalker is hot-swappable, and has no power switch.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
3.4.3
DIP Switch
The eight-position DIP switch is accessible through a cutout in the left side of the DataTalker
series enclosure; its location is shown in Figures 3-3 and 3-4.
Position 1:
Not used
Position 2:
OPEN (up)
Internal composite link device selected
Closed (down) External composite link device selected
Position 3:
OPEN (up) Data channel selected
Closed (down) Command channel selected
Not used
Position 4:
Position 5:
OPEN (up)
MMV8/16/32 mode—for communicating with an
MMV800-, MMV1600-, or MMV3200-series mux
Closed (down) 101 mode—for communicating with an MMV101
or a DataTalker
Position 6:
Position 7:
Position 8:
Not used
Not used
Not used
3.4.4
RS232C/V.35 Shunt
You can connect an external composite link device using either an RS232/V.24 or a V.35
interface to the DataTalker’s External Composite connector. To configure the DataTalker for V.35
operation you must move a shunt on the main circuit board. Two shunt sockets are located on
the back left side of the board (Figures 3-3 and 3-4). When an external composite link device with
an RS232C/V.24 interface is connected to the composite link, the shunt is installed in the RS232
socket (factory default). When the external composite link device has a V.35 interface, you must
move the shunt from the default RS232 socket to the V.35 socket. The V.35 indicator on the front
panel lights when the shunt is in the V.35 position.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4 - Unpacking and Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
4.1 Introduction
This chapter describes what to expect in your DataTalker shipping box, then describes how to
configure the DataTalker. It provides a helpful configuration summary to give you a snapshot of
how your unit is set up; summarizes options you should consider when configuring the data
channel, router port, voice/fax channel, and composite link; and then guides you step by step
through the initial configuration procedure.
4.2 Unpacking
The shipping box contains the DataTalker, an external power supply (if it is a desktop model), a
plastic bag containing the cables, and the Owner’s Manual. Additional manuals may be included
for options such as an internal link device. Inspect the contents for signs of any shipping damage.
If damage is observed, do not power up the unit; contact Multi-Tech’s Technical Support for
advice (see Chapter 8). If no damage is observed, configure the DataTalker using the information
in this chapter.
Data
RXT FCR
/
Voice
RD TM
/
Fax Concentrator
VOICE
FAX
/
/
FXS
FXS
FXO E&M FAX
FXO E&M FAX
XMT RCV XSG RSG
XMT RCV XSG RSG
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
TA
2
COMPOSITE
LINK
STATUS
DA
T
A/
VOICE
FAX
X
M
T
R
C
V
FC
C
O
M
O
R
I
G
CD
R
C
V
X
M
T
C
T
S
RTS
NS
OOS
2B
COMMAND
1
1
0
1
M
D
M
/
TA
Figure 4-1. Unpacking
The plastic bag contains two 14-foot telephone cables and test cables. The two telephone cables
may be used during installation.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4 - Unpacking and Configuration
4.3 Configuration Summary
The following chart shows possible configurations for your DataTalker. Use it as a snapshot of
how your unit is set up. Circle the parameters that apply to your unit. For example, if your unit
has the data channel set up for asynchronous communications, circle “Async.”
Data Port
Sync
Async
Optional Port
Voice/Fax Channel(s)
None
Voice/Fax
2 Channels
FXS (Phone)
External Device
V.35
1 Channel
FXO (PBX)
Internal Device
RS-232
E&M (Trunk)
Composite Link
External Device
Internal Composite
Link Device
Modem
DSU
ISDN TA
Digital
Internal Device
Connector
Dial-Up
Leased
4.4 Data Port Configuration Considerations
When configuring the data port on your DataTalker, the first question you should ask yourself is
what the port is connected to (e.g., an async channel of a host computer, a LAN gateway or
bridge, or the composite link of an MMH900 series MultiMux).
If the port is connected to an asynchronous channel of a host computer, you should
•
•
•
set the data port to “Async.”
set the speed of the port.
verify all the other parameters of the Data Port Configuration menu.
If the port is connected to a dedicated PC serving as a LAN gateway or bridge, the interface is
most likely synchronous and you should
•
•
•
•
set the data port to “Sync.”
set clocking to “Internal” or “External.”
set the desired speed if you select internal clocking.
ignore all the other parameters in the Data Port Configuration menu.
If the port is connected to the composite link of a MultiMux MMH900 series, the interface is most
likely synchronous and you should
•
•
•
•
set the data port to “Sync.”
set clocking to “Internal.”
set the desired speed.
ignore all other parameters in the Data Port Configuration menu.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
4.5 Voice/Fax Channel Configuration Considerations
When configuring the voice/fax channels on your DataTalker, the first question you should ask
yourself is what the voice/fax port is connected to. The possibilities are an in-plant telephone
switch, or PBX, (Private Branch eXchange); a PBX E&M trunk; or a telephone. If the voice/fax
channel is being connected to a PBX, use the FXO connector. If it is being connected to a
telephone, use the FXS connector. If it is being connected to a PBX E&M trunk in order to
connect two PBXs, use the E&M connector.
Caution: When you configure the local DataTalker remote interface type (option 11), you are not
setting the remote interface. You must know how the remote DataTalker is being used. You may
need to call the remote site to determine this.
If the local voice/fax channel is connected to a PBX extension and the remote voice/fax channel
is connected to a telephone, you should
•
•
set option 6 to “FXO.”
use the default remote interface type (“FXS”).
If the voice/fax channels are connected to PBX E&M trunks at both the local and the remote
sites, you should
•
•
set option 6 to “E&M.”
set the remote interface type (option 11) to “E&M.”
If the voice/fax channel is connected to a telephone, you should
•
•
•
use the default local interface type (“FXS”).
verify the remote interface type (call if necessary).
set the remote interface type (option 11) to “FXO” if the remote unit is being connected to a
PBX, or use the default “FXS” if it is being connected to a telephone.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4 - Unpacking and Configuration
4.6 Composite Link Configuration Considerations
The composite link configuration depends on the type of device used as the composite link
device. The DataTalker knows the type of composite link device being used by the setting of a
DIP switch and the sensing of conditions within the unit. In most cases you can use the default
composite link configuration.
One of four menus will appear (MMH2834 modem, DSU, ISDN terminal adapter, or external
device) depending on the device used.
If the MMH2834 modem is the composite link device, consider the following questions:
•
•
•
Is DTR dialing being used? If yes, select option 1 and enter AT commands to enable DTR
dialing.
Is the modem using a dial-up or a leased line? If dial-up, use the default configuration; if
leased, set option 4 to “Leased.”
Is the modem being used in originate or answer mode? If answer mode, use the default
configuration; if originate, set option 6 to “Originate.”
If an internal DSU is the composite link device, consider the following questions:
•
•
•
Is a DDS line being used? If yes, use the default configuration.
Is the speed of the line 56K bps? If yes, use the default configuration.
Is a 4-wire non-loaded metallic wire being used? If yes, set clocking on one unit to “Internal,”
and the other to “DDS.”
If an internal ISDN terminal adapter is the composite link device, consider the following
questions:
•
•
What are your network options, channel rate, and DTE options?
What central office switch type and protocol is provided by your ISDN service provider—
AT&T 5ESS, 5E6; Northern Telecom DMS-100, BCS-32; Siemens Stromberg-Carlson
EWSD, National ISDN-1; or NEC International Switch?
•
•
•
What are the SPID and LDN numbers assigned by your service provider?
Will the terminal adapter use dial mode operation or point-to-point leased mode operation?
Is the terminal adapter being used in originate or answer mode?
If an external device is the composite link device, consider the following questions:
•
•
Type of external interface (RS232C or V.35). If V.35, you must move an internal shunt.
Set clocking and speed to match the specific external device.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
4.7 Configuration Procedure
Table 4-1. Configuration Procedure
Step
Procedure
1
Review the configuration considerations for the data port, the voice/fax channel, and the
composite link in the previous sections.
2
Place DIP switch position 3 in the down (closed) position to enable the command port.
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
DIP
Switch
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
3
4
Desktop version: Connect the DC power supply shipped with the DataTalker to the power
connector on the back panel and to the AC outlet.
Rack-mounted version: Insert the DataTalker into a RackTalker rack.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker. Use an appropriate RS232 cable to connect
the DATA/COMMAND connector to your PC’s serial port. The terminal or PC serial port may
be labeled COM1, COM2, or Serial Port. The DATA/COMMAND connector has a DCE
physical interface.
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
DATA/COMMAND
Connector
RS232 Cable
Note: Any cables connected to the computer should be shielded to reduce interference.
5
Desktop version: Apply power to the DataTalker by placing the power switch on the back
panel in the on (I) position.
Rack-mounted version: Apply power to the RackTalker rack if it is not already on.
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Power
Switch
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4 - Unpacking and Configuration
6
Apply power to the terminal or PC. Run your PC communications software in terminal mode.
Press the ENTER key twice to establish communications with the DataTalker; the Main Menu
then appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
7
To configure the DataTalker, enter number 1 and press ENTER. The Configurations menu
appears:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
8
If the data channel is async and the channel speed is 19.2K bps, you can use the data port
configuration defaults to start. Proceed to the voice/fax channel configuration (step 11).
If the data channel speed is higher or lower than 19.2K bps, then you must change the data
port configuration. Enter 1 and press ENTER to go to the Data Port Configuration menu.
Enter 2 and press ENTER to change the speed.
Data Port Configuration
1
2
3
4
5
6
7
8
9
- Async/Sync:
- Speed:
- Word Length:
- Stop Bits:
- Parity:
Async
19200
8
1
None
CTS
Off
Off
Off
Off
Off
- Flow Control:
- Enq/Ack Flow Control:
- Echo:
- Pacing:
10 - EIA Pass Through:
11 - Pass Xon:
S
M
P
- Store All Configurations
- Main Menu
- Previous Menu
Selection : _
If you are connecting the data channel to a synchronous device, then you must change the
data port configuration. Enter 1 and press ENTER to go to the Data Port Configuration menu.
Only the first three options have to be considered for a synchronous device.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
9
Configure the data port to meet the conditions of your installation by selecting option
numbers from the menus. Refer to Chapter 6 for a description of the Data Port Configuration
menu options.
For example, if you are setting up the data port as a sync data channel, enter number 1 and
press ENTER. The Data Port Async/Sync menu appears:
Data Port Async/Sync
1
2
P
-
-
-
Async
Sync
Previous Menu
Selection : _
Select option 2 to select the sync mode of operation, and the data port configuration menu
reappears.
10 When all options for the data port configuration have been set, enter the letter S and press
ENTER to store all configurations. Then enter the letter P and press ENTER to return to the
configuration menu.
Voice/Fax Channel Configuration
11 If the voice/fax channels of both the local and remote DataTalkers are being connected to
telephone sets, i.e., both local and remote interfaces are FXS type, then you can skip the
Voice/Fax Channel Configuration menu. Proceed to the Composite Link Configuration menu.
If either the local or the remote voice/fax channel is being connected to a PBX, then you must
configure the voice/fax channel. Enter 2 and press ENTER for the Voice/Fax Channel
Configuration menu.
If two voice/fax channels are installed in the DataTalker, a voice/fax channel configuration
menu appears that allows you to configure either channel. Select the voice/fax channel that
needs to be configured.
Voice/Fax Channel 1 Configuration
1 - Destination Channel
2 - Digitizing Rate
3 - Output Level Atten.
4 - Input Level Gain
5 - Silence Suppression
6 - Local Interface Type
: 1
: 9600
: 12
: 03
: Off
: FXS
7 -
8 -
9 -
10 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
Dialtone/Wink (E&M)
Wink Timer (E&M)
: N/A
: N/A
: N/A
: FXS
11 - Remote Interface Type
12 -
13 -
14 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
: N/A
: N/A
Dialtone/Wink (E&M)
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4 - Unpacking and Configuration
12 Configure voice/fax channel 1 to meet the conditions of your installation by selecting option
numbers from the menus.
• Accept the defaults for the first five options.
• Select the local interface type (option 6).
• Select the remote interface type (option 11). The remote interface option does not change
the interface type on the remote unit; it only tells the local DataTalker how the remote unit is
configured. The actual changing of the remote interface must be done at the remote site. See
Chapter 6, “Menus,” for a description of the menu options for the voice/fax channel
configuration.
13 When you have set all options for the voice/fax channel 1 configuration, enter S and press
ENTER to store all configurations. Then enter P and press ENTER to return to the
Configurations menu.
14 If the DataTalker has a second voice/fax channel, select option 2 from the Configurations
menu, then select “Voice/Fax Channel 2 Configuration” from the Voice/Fax Channel
Configuration menu and repeat the steps for voice/fax channel 1.
Composite Link Configuration
15 From the Configurations menu, enter 3 and press ENTER to go to the Composite Link
Configuration menu.
• If the composite link device is an internal MMH2834 modem, the Internal MMH2834 Modem
Settings menu appears. Verify the configuration of the internal MMH2834 modem.
• If the composite link has an internal DSU, the Internal DSU menu appears. If the composite
link is set up as a DDS link, use the default parameters.
• If the composite link has an internal ISDN terminal adapter, the Internal TA menu appears.
Use the default flush time and go to the terminal adapter’s built-in menus (option 2) to verify
and/or change the terminal adapter’s configuration. Refer to the ISDN Terminal Adapter
Owner’s Manual for details on menu choices.
• If the composite link is configured for an external link device, the Composite Link Settings -
External Device menu appears. The default port parameters set clocking to external and
speed to 56K bps. The external device must provide the clocking, must be a sync device,
and must be full duplex. Refer to the device’s user documentation to set these parameters.
The four composite link settings menus are shown on the following pages.
Composite Link Settings - Internal MMH2834
1
- Enter AT commands to 2834
2 - On-Line XMT Rate:
3 - Speed Setting:
28800
33600
Dial
4
-
Dial/Leased:
5 - 2 or 4 Wire:
6 - Answer/Originate:
7 - Transmit Level
8 - DOD/DOI:
2 Wire
Answer
-10db
On
03min
40sec
9 - DOI Timer:
10 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
51
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
• Configure the internal MMH2834 modem to meet the conditions of your installation by
selecting option numbers from the menus.
• If you are setting up DTR dialing, select option 1, Enter AT Commands to 2834. Wait 5
seconds and then enter the following commands (press ENTER after each command):
ATDT[Number Modem to Dial]N0
AT$D1 - DTR Dialing command
AT&W - Store New Parameters to memory
Q - Return to modem menu
• If you have four-wire service from the telephone company, set option 5 to “4 Wire”;
otherwise, accept the default.
• If the MMH2834 modem is to answer automatically when it receives a call, accept the
option 6 default, “Answer”; otherwise, set it to “Originate.” (If the leased line option is
selected, one modem must be set to “Answer,” the other to “Originate.”)
When you have set all the options for the port and modem, enter S and press ENTER to
store all configurations. Then enter P and press ENTER to return to the Composite Link
Configuration menu.
16 If the composite link device is an internal DSU, verify that the configuration options meet the
conditions of your installation.
Composite Link Settings - Internal DSU
1 - Speed:
56k
DDS
2 - Clocking:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
If you need to change an option, select its number from the menu.
When you have set all the options for the DSU, enter S and press ENTER to store all
configurations. Then enter P and press ENTER to return to the configuration menu.
17 If the composite link device is an ISDN terminal adapter, verify that the configuration options
meet the conditions of your installation.
Composite Link Settings - Internal TA
1 - On-Line XMT Rate:
2 - Configure TA
128000
Off
3 - DOD/DOI:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4 - Unpacking and Configuration
To verify and/or change the terminal adapter’s configuration, select option 2, wait 5 seconds,
and enter AT!V to access the terminal adapter’s configuration menu. Refer to the ISDN
Terminal Adapter Owner’s Manual for configuration commands. To exit the terminal adapter’s
configuration menu, enter CTRL+X; then, to return to the DataTalker’s Composite Link
Settings - Internal TA menu, press ENTER, Q.
When you have set all the options for the terminal adapter, enter S and press ENTER to
store all configurations. Then enter P and press ENTER to return to the Configurations menu.
18 If the composite link device is an external device, verify that the configuration options meet
the conditions of your installation.
Composite Link Settings -External Device
1 - On-Line XMT Rate:
2 - Clocking:
56000
External
Off
3 - Back to Back:
4 - DOD/DOI:
On
5 - DOI Timer:
03min
40sec
6 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
If you need to change an option, select its number from the menu.
• Set option 1, Clocking, to match the external device; i.e., if the external device supplies
clocking, set option 1 to “External.”
• Set option 2, Speed, to the same rate as the external device.
When you have set all the options for the external device, enter S and press ENTER to store
all configurations. Then enter M and press ENTER to return to the Main Menu. Enter 5 and
press ENTER to exit command mode.
19 When you have finished configuring the DataTalker, disconnect the terminal or PC from the
command port and place DIP switch position 3 in the OPEN (up) position to change the data/
command port over to a data channel.
This completes the configuration of the DataTalker. Proceed to Chapter 5, “Installation,” to cable
the DataTalker.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5 - Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
5.1 Introduction
This chapter describes how to connect the DataTalker to your system (Table 5-1) and how to
move the RS232/V.35 shunt when a V.35 interface is used (Table 5-2). Then it describes how to
power on your DataTalker, check that the unit is cabled and configured correctly, and what to do if
you run into problems.
5.2 Cabling
Connecting the DataTalker to your system requires two to four cables, depending on how you
intend to use the DataTalker. Each cable connection will be explained in detail in the following
procedures. When you cable the unit, you should consider how you configured it in Chapter 4.
For instance, if you configured the unit for a sync data channel, you cannot connect a standard
RS232C cable to the DATA/COMMAND connector on the back of the DataTalker. The following
cabling procedures relate the cables to the configuration.
Table 5-1. Cabling Procedure
Step
Composite Link
1 Verify that DIP switch position 2 is set for the composite link device being used:
Procedure
Device
Internal
External
DIP Switch 2
OPEN (Up)
Closed (Down)
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
DIP
Switch
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Figure 5-1. DIP Switches
2
If you are using your DataTalker with an internal composite link device, connect one of the
two phone cables supplied with your unit to the appropriate internal composite connector:
MMH2834 Modem, Dial-up
Connect the RJ-11 phone cable supplied with the DataTalker from the internal modem DIAL-
UP jack on the back panel to the dial-up line jack.
RJ-11 Phone Cable
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTENAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal Modem
DIAL-UP Connector
Figure 5-2. Dial-Up Line Connection
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5 - Installation
MMH2834 Modem, Leased Line
Connect the RJ-11 phone cable supplied with the DataTalker from the internal modem
LEASED connector on the back panel to the leased line connection.
RJ-11 Phone Cable
VOICE/FAX CHANNEL
2
DATA/COMMAND
RS232C/V.35
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal Modem
LEASED Connector
Figure 5-3. Leased Line Connection
DSU
Connect the RJ-48 phone cable supplied with the DataTalker from the internal DSU/TA
DIGITAL connector on the back panel to the digital line connector.
RJ-48 Cable
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal DSU/TA
DIGITAL Connector
Figure 5-4. DSU Line Connection
ISDN Terminal Adapter
Using the RJ-48 cable supplied with the DataTalker, connect the internal DSU/TA DIGITAL
connector on the back panel to the ISDN line jack.
RJ-48 Cable
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal DSU/TA
DIGITAL Connector
Figure 5-5. ISDN Terminal Adapter Line Connection
57
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
External Modem, DSU, or ISDN Terminal Adapter
3
If the external device has an RS232 interface, connect the composite link cable supplied with
the DataTalker from the EXTERNAL COMPOSITE RS232C/V.35 connector on the back
panel to the external device.
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Composite
Link Cable
To External
Device
Figure 5-6. External Modem, DSU, or Terminal Adapter Connection
If the external device has a V.35 interface, connect a V.35 interface adapter cable (a cable
with a 34-pin Winchester male connector on one end and a DB-25S connector on the other
end) from the EXTERNAL COMPOSITE RS232C/V.35 connector to the external device. You
can order a V.35 interface adapter cable from Multi-Tech (part number 90056210).
If the external device has a V.35 interface, you must move the V.35 shunt from its default
RS232 position to the V.35 position. See Table 5-2 for the procedure on how to move the
shunt.
Data Channel
If you are connecting the data channel to an asynchronous device, such as a PC or other
4
type of host, connect an RS232C cable from the DATA/COMMAND connector on the
DataTalker to the serial port of the async device.
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
DATA/COMMAND
Connector
RS232 Cable
Figure 5-7. Data Channel Connection
If you are connecting the data channel to a sync device, connect a cable appropriate for a
synchronous interface from the DATA/COMMAND connector on the DataTalker to the
appropriate connector on the sync device.
Voice/Fax Channel
5
If you are connecting the voice/fax channel to a station device (a normal telephone, a KTS
telephone, or a fax machine), connect an RJ-11 phone cable from the VOICE/FAX
CHANNEL FXS connector on the DataTalker to the station instrument.
RJ-11
Telephone
Cable
VOICE/FAX CHANNEL
2
DATA/COMMAND
RS232C/V.35
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
VOICE/FAX
CHANNEL 1
FXS Connector
Figure 5-8. Telephone Connection
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5 - Installation
If you are connecting the voice/fax channel to the station side of a PBX, connect an RJ-11
phone cable from the VOICE/FAX CHANNEL FXO connector on the DataTalker to the station
side of the PBX. Refer to the PBX manual for the station side connection.
VOICE/FAX CHANNEL
2
DATA/COMMAND
RS232C/V.35
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
VOICE/FAX
CHANNEL 1
FXO Connector
RJ-11 Phone Cable
Figure 5-9. PBX Connection
If you are connecting the voice/fax channel to a PBX E&M trunk, connect an RJ-48 phone
cable from the VOICE/FAX CHANNEL 1 E&M connector on the DataTalker to an E&M trunk
connector on the PBX. (Voice/Fax Channel 2 does not have an E&M connector.) Also, run a
ground wire from the ground connector on the back of the DataTalker or RackTalker to frame
ground on the PBX E&M trunk. Refer to the PBX manual for the trunk connection.
VOICE/FAX CHANNEL
2
To PBX
Trunk
DATA/COMMAND
RS232C/V.35
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
EXTERNAL COMPOSITE
MODEM
DSU/TA
VOICE/FAX CHANNEL
1
POWER
INTERNAL COMPOSITE
VOICE/FAX
CHANNEL 1
E&M Connector
RJ-48 Cable
Figure 5-10. PBX E&M Trunk Connection
This completes the cabling of your DataTalker. Proceed to Table 5-3 to power on and test your
unit.
59
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
5.3 V.35 Shunt
Table 5-2. V.35 Shunt Procedure
Step
Procedure
1
2
Desktop version: Unplug the power supply from the back of the unit.
Rack version: Remove the unit from the RackTalker rack. Go to step 4.
Desktop version only: Turn the unit upside down and remove the two cabinet mounting
screws from the middle of the cabinet.
Data
RXT FCR
/
Voice
RD TM
/
Fax Concentrator
VOICE
FAX
/
/
FXS
FXS
FXO E&M FAX
FXO E&M FAX
XMT RCV XSG RSG
XMT RCV XSG RSG
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
TA
2
COMPOSITE
LINK
STATUS
DATA/
COMMAND
VOICE
FAX
X
M
T
R
C
V
FC
COM ORIG
CD
RCV XMT CTS
RTS
NS
OOS
2B
1
101 MDM / TA
Cabinet
Mounting
Screws (2)
Figure 5-11. Cabinet Mounting Screws
3
Desktop version only : Turn the cabinet right-side up, tilt the back down slightly, and the base
unit will slide out of the cabinet.
4
5
Desktop and rack versions: Place the unit with the LEDs facing you.
Pry the shunt out of the RS232 socket and insert it into the V.35 socket. Rack version: Go to
step 8.
RS-232
Shunt
V.35
Shunt
Figure 5-12. V.35 Shunt Location (Desktop Version)
6
7
8
Desktop version only: Slide the base back into the cabinet with the LEDs toward the front and
the rear grounding tabs pressing against the side of the cabinet.
Desktop version only: Turn the unit upside down and replace the two cabinet mounting
screws.
Desktop version: Turn the unit right-side up and reconnect the power supply.
Rack version: Slide the unit into the RackTalker card guides and, after ensuring that the
DataTalker is fully seated, fasten the retaining screws.
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5 - Installation
5.4 Power-On and Checkout
The desktop and rack-mounted versions of the DataTalker differ in how power is applied. The
desktop version has a power switch that you must turn on. The rack version has no power
switch; you apply power by inserting it into a powered-up rack. It is always on as long as the rack
is powered up.
Table 5-3. Power-On and Checkout Procedure
Step
Procedure
1
Desktop version: Ensure that the power supply is connected to the unit’s power connector
and an AC outlet.
Rack version: Ensure that the DataTalker is properly seated in a RackTalker rack. Tighten the
front panel screws to ensure a good connection with the RackTalker power bus.
2
Desktop version: Apply power (press the power switch on the back of the unit to I [on]).
Rack version: Plug the RackTalker rack into an AC outlet, if it is not already powered up.
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Power
Switch
Figure 5-13. Power Switch (Desktop Version)
3
Verify the states of the following composite link LEDs. The LED should be on for each
installed feature and off for each uninstalled feature:
Composite Link Device
Internal 28.8K bps modem
Internal 56K DSU
Internal ISDN terminal adapter
External modem, DSU, or TA
External V.35 interface
LED
MDM
DSU
TA
EXT
V35
Data / Voice / Fax Concentrator
VOICE
FAX
/
/
FXS
FXS
FXO E&M FAX
FXO E&M FAX
XMT RCV XSG RSG
XMT RCV XSG RSG
RXT
FCR
RD
TM
V35
28.8
56
EXT MDM DSU
DTR DBUP OH
TA
2
COMPOSITE
LINK
STATUS
DATA/
COMMAND
VOICE
FAX
XMT RCV
FC
COM ORIG
CD
RCV XMT CTS
RTS
NS
OOS
2B
1
101 MDM/TA
Figure 5-14. Front Panel
4
5
Establish a link with the remote DataTalker if the local DataTalker is not configured to link
automatically.
Verify that the composite link is communicating with the remote DataTalker. The RD LED
should be off. The following LEDS should be on:
Terminal adapter:
Modem:
CD, RCV, XMT, CTS, DTR, and 2B (if so configured)
CD, RCV, XMT, CTS, and DTR
DSU:
CD, RCV, XMT, CTS, and RTS
61
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
6
Verify that the voice/fax channel is connected at the remote site. One of the following
conditions will apply depending on how your local and remote sites are set up:
• If the local voice/fax channel is connected to a telephone switch in your facility (FXO
connection) and the remote site has just a telephone (FXS connection), dial the number of
the extension plugged into the FXO jack of the local DataTalker and listen for a ringing at the
remote site. If a voice conversation can take place, the connection is good.
• If the local and remote DataTalkers have only a telephone connected to the voice/fax
channel, pick up the telephone hand set and listen for a ringing at the remote site. If a voice
conversation can take place, the connection is good.
• If the local and remote DataTalker each has an E&M trunk connection to its PBX, follow the
PBX procedure for dialing any extension at the remote PBX. If a voice conversation can take
place, the connection is good.
7
8
Now have the remote site call the main officeto see if they can transfer data and establish a
phone conversation. If the remote site is set up for DTR dialing, they only have to power up
the remote DataTalker to dial; if it is a leased line connection, they have to pick up the
telephone to make the main office phone ring; if it is a dial-up situation, they must dial the
main office number to make its phone ring.
If the above functional tests do not all work, you must conduct further tests. Analyze the
failure one function at a time to determine what does and doesn’t work. The DataTalker has
three basic functions:
• Composite link
• Data channel
• Voice/fax channel
Composite Link
If the composite link is down, refer to the troubleshooting procedures in Chapter 7. Also, look
for the following items:
• The composite link cabling does not match the link device. Ensure that the link configuration
matches how the link is cabled.
• The shunt is in its default position when an external V.35 interface device is connected. See
Table 5-2.
• The remote site (home office) cannot contact the main office when using a dial-up link. DTR
dialing commands may be incorrect; refer to Chapter 6 while verifying the main office
telephone number.
• DIP switch position 2 is set for the wrong device. See the cabling procedure in Table 5-1.
• The remote site cannot contact the main office. The remote site has a wrong phone number
for the main office DataTalker or the leased line is not set up by the telephone company.
Data Channel
If the channel device (the device connected to the data channel) is not communicating with
the DataTalker, check the following items:
• DIP switch position 3 is closed (down). Flip the position 3 switch up.
• The data channel configuration is wrong. See Chapter 4.
• The async or sync cable is wrong. See Appendix C.
62
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5 - Installation
Voice/Fax Channel
If the voice/fax channel is not communicating with the remote site or the remote site cannot
communicate with you, check the following items:
• The channel configuration does not match how the channel is cabled. Verify that the
channel configuration and cabling match.
• The remote DataTalker does not match the remote interface type. See Chapter 4.
• The telephone or fax machine is connected to the wrong connector. Verify the cable
connection.
• The telephone must be an analog phone. Check with your telephone people to ensure that
the telephone is not a digital instrument.
• The line connection to your local telephone switch is a digital line. Have your telephone
people provide an analog line.
This completes the installation of your DataTalker.
63
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
64
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
6.1 Introduction
The menu system for the DataTalker provides a set of user-friendly configuration menus that are
accessible from a main menu. The Main Menu contains five options that allow you to configure
your DataTalker, display statistics, reset options, run diagnostic tests, and exit the command
mode.
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
To select one of the options from the Main Menu, enter the number corresponding to the option
and press ENTER. A submenu is displayed that allows you to configure your DataTalker; display
statistics; reset a voice/fax channel, data channel or the complete unit; or run one of many
diagnostics tests.
6.2 Configurations Menu
From the Configurations menu you can configure the data port, voice/fax channel(s), or
composite link; display factory defaults; store all current configurations; or return to the Main
Menu.
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
To configure the data port, voice/fax channel(s), or composite link, enter the corresponding option
number and press ENTER. To change to factory defaults, enter number 4 and press enter. You
can set factory defaults for the entire unit or for only the composite link, data channel, or the
voice/fax channels. Select the option you wish to change, and a message will appear on your
screen saying to wait for 10 seconds. Then press ENTER to return to the Main Menu. To store
the current configuration, enter S and press ENTER. To return to the Main Menu, enter M and
press ENTER.
66
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
6.2.1
Data Port Configuration
The Data Port Configuration menu allows you to configure the data channel for either
asynchronous or synchronous operation, depending on the type of device connected to the
channel. If the port is configured for synchronous operation, refer to Sync Data Port
Configuration.
When the port is configured for asynchronous operation, options such as speed, flow control, and
pacing may need to be changed. The following Data Port Configuration menu displays the default
parameters for async mode of operation:
Data Port Configuration
1
2
3
4
5
6
7
8
9
- Async/Sync:
- Speed:
- Word Length:
- Stop Bits:
- Parity:
Async
19200
8
1
None
CTS
Off
Off
Off
Off
Off
- Flow Control:
- Enq/Ack Flow Control:
- Echo:
- Pacing:
10 - EIA Pass Through:
11 - Pass Xon:
S
M
P
- Store All Configurations
- Main Menu
- Previous Menu
Selection : _
The Async/Sync option configures the port for either asynchronous or synchronous operation.
When an asynchronous device such as a PC or a host computer is connected to the channel, the
data port needs to be configured for asynchronous operation. The default for this option is Async.
The Speed option needs to be set when the async device is operating at a channel speed other
than 19.2k. When the data channel is connected to an asynchronous device, the channel baud
rate is from 300 bps to 115.2K bps. The default channel speed is 19.2k bps.
The Word Length option sets the number of bits in a word. The word length range is 5 to 8 bits.
The default is 8 bits.
The Stop Bits option sets the number of stop bits. The number of stop bits is 1, 1.5, 2. The
default is 1 bit.
The Parity option sets parity for odd, even or none. Under normal conditions, parity is set to
none. The default is none.
The Flow Control option allows for two types of flow control: the software-based XON/XOFF and
the hardware-based Clear to Send (CTS). The default condition is CTS. Flow control is the
means by which data flow from the channel device into the DataTalker is controlled. Flow control
is necessary when the data handling capacity of the data channel cannot keep up with the
volume of data sent to it. When the channel device controls data flow to itself, it is called pacing
(see Pacing option). The combination of flow control from the channel device and pacing to the
channel device is how data transfers are regulated so that no data is lost.
DATATALKER-INITIATED
FLOW CONTROL
CHANNEL DEVICE-
INITIATED PACING
DATA
DATA
Channel
DataTalker
Device
Channel
Device
DataTalker
Flow control stops the input
of data to the DataTalker
Pacing stops the output of
data from the DataTalker
The Enq/Ack Flow Control option is a special flow control protocol used in Hewlett Packard
computer systems. This option is sometimes referred to as Enquire/Acknowledge flow control
because it’s based on the computer sending an enquiry (ENQ) and then expecting an
acknowledgment (ACK). The default condition for this option is off.
67
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
The Echo option enables data entered on the channel device keyboard to be returned to the
channel device monitor. The purpose of this option is so that an operator will not experience
undue delays in seeing entered data appear on their monitor. The default condition for the echo
option is off.
The Pacing option controls the data flow to the channel device. This option only applies to the
async mode of operation. Pacing is necessary when the flow of data to a device operating on the
data channel is more than it can process. If the channel device cannot process the volume of
data sent to it, then the pacing option should be turned on. The pacing method used is
determined by the type of flow control. The default condition is for this option to be turned off.
The EIA Pass Through option allows the channel device to receive EIA control signals through
the DataTalker. This option only applies during the async mode of operation. Since, in normal
interactive operation, the existence of a DataTalker should be transparent to the user, the EIA
pass through option allows a terminal to operate as if it were connected directly to a
communications line and not through a DataTalker. This is done by allowing selected pins
(signals) on one DataTalker to be passed through to selected pins on a remote DataTalker. The
default condition is for this option to be turned off. The following diagram shows how the EIA
pass through option routes the selected signals:
DataTalker
A
DataTalker
B
8 OUT
6 OUT
22 OUT
IN 4
IN 20
IN 25
Composite Link
Facility
4 IN
OUT 8
20 IN
25 IN
OUT 6
UT 22
The Pass Xon option enables the XON/XOFF flow control signals to be passed on to the channel
device. This option only applies during the async mode of operation. This option has to be used
in conjunction with the software-based XON/XOFF flow control option. The default condition is for
this option to be turned off, and normally it should remain off.
68
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
6.2.2
Sync Data Port Configuration
The Data Port Configuration menu allows you to configure the data channel for either
asynchronous or synchronous operation, depending on the type of device connected to the
channel.
When the port is configured for synchronous operation, the following Data Port Configuration
menu displays the default parameters:
Data Port Configuration
1 - Async/Sync:
Sync
2 - Speed:
19200
Internal
Flags
NRZ
3 - Clocking:
4 - Idle Condition:
5 - NRZ/NRZI Encoding:
6 - CRC Preset:
All 1s
Off
7 - Inter-frame Timer:
S - Store All Configuations
M - Main Menu
P - Previous Menu
Selection : _
The Async/Sync option configures the port for either asynchronous or synchronous operation.
When a synchronous device such as a LAN bridge or router is connected to the channel, the
data port needs to be configured for synchronous operation.
The Speed option needs to be set when the sync device is operating at a channel speed other
than 19.2k. When the data channel is connected to a synchronous device, the channel baud rate
is from 300 bps up to 128K bps. The default channel speed is 19.2k bps.
The Clocking option needs to be set for either internal or external clocking. When the DataTalker
is providing the clocking, the option needs to be set for internal clocking. When clocking is
provided by the synchronous device, this option must be set for external clocking. The default for
the clocking option is internal clocking.
The Idle Condition option must be set to match the idle condition of the synchronous device
connected to the data port. The idle condition must set when the synchronous data line is in an
idle condition (i.e., no data frames are being transmitted). The default condition is to continuously
send SDLC flags (Flags). The other idle condition is the mark state (Mark). The transmit LED
will be off during idle time if the synchronous device is in the mark state during idle conditions.
The NRZ/NRZI Encoding option refers to the fact that synchronous data can be encoded by
using either the NRZ (Non-Return to Zero) or NRZI (Non-Return to Zero Inverted) method. This
option must match the synchronous device’s encoding. The default is NRZ. Most synchronous
devices are configurable. If a synchronous device is not configurable, it is set to NRZ. Refer to
the device’s user documentation for the encoding method.
The CRC Preset option allows the user to specify whether the polynomial used to calculate the
CRC for each frame is present to all 1s or all 0s. This option must match the synchronous
device’s CRC setting. The default is All 1s.
The Inter-frame Timer option can be changed to make the DataTalker wait a specified length of
time between frames being transmitted on the data channel. The user can choose delay times of
2,5,10 and 15 milliseconds. A typical use for this parameter is to simulate transmission delays
encountered with equipment that toggles hardware signals after transmission of each frame, like
PC cards used to connect to legancy systems. The following options can be specified for the
timer: Off, 2mS, 5mS, 10mS, and 15mS. The default is off.
69
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
6.2.3
Voice/Fax Channel Configuration
The Voice/Fax Channel Configuration menu is displayed only if the second voice/fax channel
card is installed in the DataTalker. If only one voice/fax channel is installed in the DataTalker, this
menu does not appear. If you select the Voice/Fax Channel(s) Configuration option from the
Configurations menu when you have only one voice/fax channel, the Voice/Fax Channel 1
Configuration menu is displayed:
Voice/Fax Channel Configuration
1 - Voice/Fax Channel 1 Configuration
2 - Voice/Fax Channel 2 Configuration
S - Store All Configuations
M - Main Menu
P - Previous Menu
Selection: _
To configure voice/fax channel 1, enter number 1 and press ENTER. To configure the second
voice/fax channel 2 (if installed), enter number 2 and press ENTER. The options for both voice/
fax channels are the same. To return to the previous menu, enter P (upper or lower case) and
press ENTER. To return to the Main Menu, enter M and press ENTER.
Voice/Fax Channel 1 Configuration
The Voice/Fax Channel 1 Configuration menu allows you to select the voice/fax channel 1
operating conditions:
Voice/Fax Channel 1 Configuration
1 - Destination Channel
2 - Digitizing Rate
3 - Output Level Atten.
4 - Input Level Gain
5 - Silence Suppression
6 - Local Interface Type
: 1
: 9600
: 12
: 03
: Off
: FXS
7 -
8 -
9 -
10 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
Dialtone/Wink (E&M)
Wink Timer (E&M)
: N/A
: N/A
: N/A
: FXS
11 - Remote Interface Type
12 -
13 -
14 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
: N/A
: N/A
Dialtone/Wink (E&M)
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The Destination Channel option selects the voice/fax channel at the remote DataTalker that will
receive the voice/fax traffic. The options are 1 for the remote voice/fax channel 1 and 2 for the
remote voice/fax channel 2. The default is 1.
The Digitizing Rate option selects from two digitized or compressed rates of 9600 and 16000
bps. The default is 9600 bps. Note that with the silence suppression option, less bandwidth is
used.
The Output Level Attentuation option selects the output signal level of the voice/fax channel
transmission. This will change the volume level that the person at the receiving DataTalker hears.
As the output level attentuation increases, the amplitude decreases. The signal levels are
incremented in decibel levels of 0.75 dB and range from zero to 31. You must enter two digits. No
signal level attentuation is 0 dB.
70
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
The output level attentuation needs to be set at the DataTalker that is receiving (hearing).
Increasing the output level gain at the transmitting DataTalker will have no affect on the loudness
heard by the person at the receiving DataTalker:
DataTalker
PSTN
DataTalker
OL
Sounds
2db
Louder
Talk
Increase
2db
Sounds
2db
OL
Talk
Louder Increase
2db
Note: For the best results, increase or decrease both the local output level (OL) and remote input
level (IL) settings by a small amount to change the volume level heard at the local voice/fax
channel.
The default settings are as follows:
Configuration
Local
Remote
IL
4
OL
0
IL
6
OL
1
FXS to FXO
FXS to FXS
E&M to E&M (4-wire)
3
3
12
4
3
3
12
4
The Input Level Gain option selects the gain of the input voice/fax signal for voice/fax channel.
As the input level gain increases, the volume level increases. The input level gain ranges from 0
to 24 in increments of 1db with 0db producing no gain. Two digits have to be entered.
When the input level on the local DataTalker is adjusted, the volume level heard on the remote
DataTalker will change accordingly. The input level gain needs to be set on the transmitting
DataTalker (talking). This will increase the volume that the person at the receiving DataTalker
hears. To increase the input level gain at the receiving DataTalker will have no affect on what this
person hears.
PSTN
DataTalker
DataTalker
IL
Talk
Hear
Increase
2db
2db Louder
IL
Talk
Increase
2db
Hear
Produces 2db
Louder Volume
Note: For best results, increase or decrease both the local output level (OL) and remote input
level (IL) settings by a small amount.
The default settings are as follows:
Configuration
Local
Remote
IL
4
OL
0
IL
6
OL
1
FXS to FXO
FXS to FXS
E&M to E&M (4-wire)
3
3
12
4
3
3
12
4
The Silence Suppression option keeps moments of silence from using up bandwidth on the
composite link. The options are Off, Medium, and Maximum. Typically, a voice conversation is 50
to 60% silence. Silence suppression is helpful when using a slow composite link speed such as
19.2K bps. When silence suppression is off, all sound passes through the link, even silence.
Silence suppression is active when there is no activity on the voice/fax channel. The maximum
setting increases the volume necessary for sound to be sent over the link.
71
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
The Local Interface Type option configures the local voice/fax channel interface. The options
are for an FXS, FXO, or E&M interface. When the voice/fax channel is connected to a telephone
set or fax machine, the local interface type must be FXS. When the voice/fax channel is
connected to the station side of a PBX, the local interface type must be FXO. When the voice/fax
channel is connected to a PBX E&M trunk, the local interface type must be E&M. When the local
DataTalker is configured for an FXO interface, the remote DataTalker must be configured for an
FXS interface. FXS to FXS is another local-to-remote interface. When used to connect PBXs,
both local and remote DataTalkers must be configured for E&M.
The Ground/Loop Start (FXS) option selects between ground start and loop start. Select
Ground when the DataTalker local interface type is FXS ground start and the remote interface is
E&M wink. The default is Loop.
The 2 or 4 Wire (E&M) option selects how the DataTalker is connected to the PBX E&M trunk.
The choice is between 2- and 4-wire connections. The default is 4 Wire.
The Dialtone/Wink (E&M) option slects between dialtone and wink signals when the interface
type is E&M. The default is Dialtone.
The Wink Timer (E&M) option is used in the E&M interface to delay the sending of address
information from the remote MultiMux. The wink timer range is from 100 to 350 milliseconds. The
default delay is 250 ms.
The Remote Interface Type option informs the local voice/fax channel of how the remote
channel may be configured. The options are for an FXS, FXO, or E&M interface. Caution: This
option does not actually change the remote interface. You may have to contact the remote site for
verification of its actual interface. When the remote voice/fax channel is connected to a telephone
set or fax machine, the remote interface type must be FXS. When the remote voice/fax channel
is connected to the station side of a PBX, the remote interface type must be FXO. When the
remote voice/fax channel is connected to a PBX E&M trunk, the remote interface type must be
E&M. If the remote DataTalker is configured for an FXO interface, the local DataTalker must be
configured for an FXS interface. FXS to FXS is another remote-to-local interface. When used to
connect PBXs, both local and remote DataTalkers must be configured for E&M. If erratic voice/
fax operation is noticed, the remote interface may be incorrectly set at the local DataTalker.
The Ground/Loop Start (FXS) option selects between ground start and loop start. Select
Ground when the DataTalker local interface type is FXS ground start and the remote interface is
E&M wink. The default is Loop.
The 2 or 4 Wire (E&M) option selects how the DataTalker is connected to the PBX E&M trunk.
The choice is between 2- and 4-wire connections. The default is 4 Wire.
The Dialtone/Wink (E&M) option slects between dialtone and wink signals when the interface
type is E&M. The default is Dialtone.
72
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
6.2.4
Composite Link Configuration
The Composite Link Configuration menu that is displayed depends on whether an internal or
external device is installed as well as on the position of DIP switch position 2. If DIP switch
position 2 is in the up (OPEN) position and an internal MMH2834 modem installed, the
Composite Link Settings menu for the MMH2834 modem is displayed. If DIP switch position 2 is
in the up (OPEN) position and an internal DSU is installed, the Composite Link Settings menu for
a DSU is displayed. If DIP switch position 2 is in the up (OPEN) position and an internal ISDN
terminal adapter is installed, the Composite Link Settings menu for a terminal adapter is
displayed. If DIP switch position 2 is in the down (closed) position, the Composite Link Settings
menu for an external device is displayed.
Composite Link Settings - Internal MMH2834
The Composite Link Settings - Internal MMH2834 menu allows you to configure the composite
link for an MMH2834 modem. Additional AT commands may be needed to set up the modem.
(See Appendix F.)
Composite Link Settings - Internal MMH2834
1
- Enter AT commands to 2834
2 - On-Line XMT Rate:
3 - Speed Setting:
28800
33600
Dial
4
-
Dial/Leased:
5 - 2 or 4 Wire:
6 - Answer/Originate:
7 - Transmit Level
8 - DOD/DOI:
2 Wire
Answer
-10db
On
03min
40sec
9 - DOI Timer:
10 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The Enter AT Commands to 2834 option allows you to use AT commands to reconfigure the
MMH2834 through the command port. For example, to set up the MMH2834 for DTR dialing,
select this option and enter the following commands:
ATDT[Number to Dial]N0
AT$D1 (DTR dialing command)
AT&W (Store new parameters to memory)
Q (Return to menus)
Additional AT commands are described in Appendix F.
The On-Line Transmit (XMT) Rate option displays the on-line transmit rate of the composite link
device. If the compoiste link is not up, off-line is displayed. The On-Line XMT Rate may be
different than the Speed Setting.
The Speed Setting option configures the link port for a speed of 9600, 14400, 19200, or 33600
bps. A 2834 Speed Setting submenu is displayed when this option is selected. The default
speed setting is 33600 bps.
2834 Speed Setting
1 - 33600
2 - 19200
3 - 14400
4 - 9600
P - Previous Menu
Selection : _
73
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
The Dial/Leased option selects the type of connection to the telephone company. If the data line
provided by the telephone company is a dial-up line, then you must select the dial option. The
options are Dial and Leased with the default being Dial.
The 2 or 4 Wire option selects how the MMH2834 modem is connected to the telephone line.
E.g., if the telephone company is supplying a 4-wire lease, select the 4 Wire option. The options
are 2 Wire and 4 Wire, with the default being 2 Wire.
The Answer/Originate option selects the line frequency used when leased line operation is
selected. When dial operation is selected, it enables or disables auto answer. For leased line
operation, one MMH2834 modem should have Originate selected and the other MMH2834
should have Answer selected. For dial operation, select Answer if the MMH2834 needs to answer
an incoming call.
The Transmit Level option selects the output transmission level in decibels. The options are 0
and -10db, with a default of -10db. The closer the transmit level is to zero the greater the level
(strength) of the output signal. This option should only be changed under the direction of Multi-
Tech Tech Support personnel.
The Dial On Demand (DOD)/Disconnect On Inactivity (DOI) option drops DTR to the
MMH2834 modem to disconnect if the inactivity timer has expired and raises DTR to reconnect if
the voice/fax or data channel goes active. The default is to have the DOD/DOI option turned off.
If this option is off, options 9 and 10 do not appear on the menu.
The Disconnect on Inactivity (DOI) Timer option signals the MMH2834 to hang up the
composite link by dropping DTR to it when the timer expires. When the DOI Timer option is
selected, a submenu is displayed in which you can enter the number of minutes that the inactivity
timer is set for. The range of the timer in minutes is 01 to 99. The default setting for the timer is
three minutes.
Disconnect On Inactivity Timer. This is
the timer for inactivity -> DTR drop.
x - Enter the number of minutes
P - Previous Menu
Selection : _
The Dial On Demand (DOD) Toggle DTR option activates the DTR Toggle Timer. When activity
on the voice/fax or data channels cause DTR to go high telling the MMH2834 modem to DTR
dial, this timer is started. If the connection is established before this timer expires, the timer is
stopped. Otherwise, when the timer expires, DTR is toggled to tell the MMH2834 to dial again
and this timer is restarted. The default is 40 seconds.
DTR Toggle Timer. This is the timer to
toggle DTR if the link does not come up.
x - Enter the number of seconds(0 is off)
P - Previous Menu
Selection : _
74
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
Composite Link Settings - Internal 56K DSU
The Composite Link Settings - Internal DSU menu allows you to configure the composite link for
a DSU. The default parameters for an internal DSU are displayed in the following menu:
Composite Link Settings - Internal DSU
1 - Speed:
56k
DDS
2 - Clocking:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The Speed option sets the speed of the internal DSU. The options are 2400, 4800, 9600, 19200
and 56000 bps with the default being 56K bps.
The Clocking option allows the internal DSU to accept timing from its internal timing oscillator or
from the DDS network’s receive bipolar signal. The options are Internal and DDS clocking with
the default being DDS clocking.
Composite Link Settings - Internal TA
The Composite Link Settings - Internal TA menu allows you to configure the composite link for an
ISDN terminal adapter using the terminal adapter’s built-in configuration menu.
Composite Link Settings - Internal TA
1 - On-Line XMT Rate:
2 - Configure TA
128000
Off
3 - DOD/DOI:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The Link Transmit Rate option displays the speed that the DataTalker is senseing on the
composite link.
The Configure TA option allows you to verify and/or change the terminal adapter’s configuration
using its internal configuration menu. After you select the option, wait five seconds, then enter
AT!V to access the terminal adapter’s configuration menu. To change a setting, enter the menu
choice number and press ENTER. Refer to the ISDN Terminal Adapter Owner’s Manual for
descriptions of the terminal adapter settings. To exit the terminal adapter’s configuration menu,
enter CTRL+X; then, to return to the DataTalker’s Composite Link Settings - Internal TA menu,
press ENTER, Q.
75
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
The Dial On Demand (DOD)/Disconnect On Inactivity (DOI) option drops DTR to the terminal
adapter to disconnect if the inactivity timer has expired and raises DTR to reconnect if the voice/
fax or data channel goes active. When this option is turned ON, a new menu is displayed. The
default is to have the DOD/DOI option turned off.
Composite Link Settings - Internal TA
1 - On-Line XMT Rate:
2 - Configure TA
3 - DOD/DOI:
128000
On
03min
40sec
4 - DOI Timer:
5 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The Disconnect on Inactivity (DOI) Timer option signals the terminal adapter to hang up the
composite link by dropping DTR to it when the timer expires. When the DOI Timer option is
selected, a submenu is displayed in which you can enter the number of minutes that the inactivity
timer is set for. The range of the timer in minutes is 01 to 99. The default setting for the timer is
three minutes.
Disconnect On Inactivity Timer. This is
the timer for inactivity -> DTR drop.
x - Enter the number of minutes
P - Previous Menu
Selection : _
The Dial On Demand (DOD) Toggle DTR option activates the DTR Toggle Timer. When activity
on the voice/fax or data channels cause DTR to go high telling the terminal adapter to DTR dial,
this timer is started. If the connection is established before this timer expires, the timer is
stopped. Otherwise, when the timer expires, DTR is toggled to tell the terminal adapter to dial
again and this timer is restarted. The default is 40 seconds.
DTR Toggle Timer. This is the timer to
toggle DTR if the link does not come up.
x - Enter the number of seconds(0 is off)
P - Previous Menu
Selection : _
76
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
Composite Link Settings - External Device
The Composite Link Settings - External Device menu allows you to configure the composite link
for an external device. The default parameters for an external device are displayed in the
following menu:
Composite Link Settings -External Device
1 - On-Line XMT Rate:
2 - Clocking:
56000
External
Off
3 - Back to Back:
4 - DOD/DOI:
On
5 - DOI Timer:
03min
40sec
6 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
The On-Line Transmit (XMT) Rate option displays the on-line transmit rate of the composite link
device. If the composite link is not up, Off-Line is displayed.
The Clocking option allows the internal composite link to accept timing from either its internal
timing oscillator or from a synchronous full-duplex external device. The options are Internal and
External clocking, with a default of External.
The Back to Back option is used to test the port by connecting two DataTalkers together using a
back-to-back cable. The options are On and Off with a default of Off.
The Dial On Demand (DOD)/Disconnect On Inactivity (DOI) option to the external device to
disconnect if the inactivity timer has expired and raises DTR to reconnect if the voice/fax or data
channel goies active. The default is to have the DOD/DOI option turned off. If this option is off,
options 5 and 6 do not appear on the menu.
The Disconnect on Inactivity (DOI) Timer option signals the external device to hang up the
composite link by dropping DTR to it when the timer expires. When the DOI Timer option is
selected, a submenu is displayed in which you can enter the number of minutes that the inactivity
timer is set for. The range of the timer in minutes is 01 to 99. The default setting for the timer is
three minutes.
Disconnect On Inactivity Timer. This is
the timer for inactivity -> DTR drop.
x - Enter the number of minutes
P - Previous Menu
Selection : _
The Dial On Demand (DOD) Toggle DTR option activates the DTR Toggle Timer. When activity
on the voice/fax or data channels cause DTR to go high telling the external device to DTR dial,
this timer is started. If the connection is established before this timer expires, the timer is
stopped. Otherwise, when the timer expires, DTR is toggled to tell the external device to dial
again and this timer is restarted. The default is 40 seconds.
DTR Toggle Timer. This is the timer to
toggle DTR if the link does not come up.
x - Enter the number of seconds(0 is off)
P - Previous Menu
Selection : _
77
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
6.3 Statistics
The Statistics menu allows you display or clear the composite link statistics, or return to the
previous menu or to the Main Menu.
Statistics
1 - View Composite Link Statistics
2 - Clear Composite Link Statistics
M - Main Menu
P - Previous Menu
Selection : _
To display or clear the composite link statistics, enter the corresponding option number and press
ENTER. To return to the previous menu, enter P and press ENTER. To return to the Main Menu,
enter M and press ENTER.
The Composite Link Statistics display provides information concerning the operation of the
composite link that can aid you in testing for problems on the link.
Composite Link Statistics
Elasped Time
Minutes
: 00 Days 00 Hours 00
Data Blocks Transmitted
Data Blocks Retransmitted
Data Blocks Received
Receive Block Errors
:
:
:
:
0
0
0
0
0
0
0
0
Voice/Fax Blocks Transmitted :
Voice/Fax Blocks Received
Link Alarms
Remote Downs
:
:
:
Comparing the number of blocks transmitted with the number of retransmits needed to get data
over the link can indicate a line problem. Comparing the blocks received and receive block errors
indicates the same problem from the other end of the link. Comparative numbers that you might
encounter could be 10,000 blocks transmitted (or received) with 500 or 1000 retransmits (or
receive block errors). Link alarms simply tell you that there are some sort of problems on the link.
You will find that the link alarms numbers will correspond to the retransmit and receive block
numbers. Specifically, a link alarm means that it has been 10 seconds since the DataTalker has
received an acknowledgement. Normally, three acknowledgements are received during a 10-
second period.
The remote down entry means that the DataTalker has sent data 30 times and could not get it
through (the link has been broken).
78
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
6.4 Reset Options
The Reset Options menu allows you to reset the unit, the data and voice/fax channels, each
voice/fax channel, or just the data channel.
Reset Options
1 - Reset Unit
2 - Reset Data and Voice/Fax Channels
3 - Reset Voice/Fax Channel 1
4 - Reset Voice/Fax Channel 2
5 - Reset Data Channel
M - Main Menu
P - Previous Menu
Selection : _
To reset the unit, enter 1 and press ENTER. To reset the data and voice/fax channels, 2 and
press ENTER. To reset either voice/fax channel, enter the appropriate number and press
ENTER. To reset just the data channel, enter 5 and press ENTER. To return to the previous
menu, enter P and press ENTER. To return to the Main Menu, enter M and press ENTER.
6.5 Diagnostic Tests
The Diagnostic menu allows you to run three different tests, display the DIP switch settings, and
return to the previous menu or the Main Menu. The loop test option produces a submenu that
allows either a data loopback function or voice loopback function. (Tests for the ISDN terminal
adapter are described in the ISDN Terminal Adapter Owner’s Manual.)
Diagnostics
1 - Loop Test
2 - Memory Test
3 - Watch Dog Test
4 - Dip Switch Definitions and Settings
5 - Product and Firmware ID
M - Main Menu
P - Previous Menu
Selection : _
The Loop Test option checks the operation of the local unit. When this option is selected, a loop
test menu is displayed. See “Loop Tests” in section 6.5.1.
The Memory Test option checks the on-board memory. When this option is selected, a warning
message is displayed. The memory test will destroy all stored configurations. See “Diagnostic
Testing” in section 7.12.
The Watch Dog Test option verifies the watch dog timer circuitry. A message is displayed that
the test will reset the unit. See “Diagnostic Testing” in section 7.12.
The Dip Switch Definitions and Settings option displays a screen that shows the definition of
each switch and its current setting.
The Product and Firmware ID option defines the product and its current firmware release
version.
79
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
6.5.1
Loop Tests
The Loop Tests menu provides either a voice loopback or a composite link loopback that
depends on the type of link device.
Loop Tests
1
2
- Voice Loopback
- Composite Link Loopback
M - Main Menu
P - Previous Menu
Selection : _
The following messages are displayed, depending on the loopback test.
Voice Loopback Test
Voice Loop Test. If you have one voice channel, it loops to itself. If you have two voice channels,
voice channel 1 loops to voice channel 2.
Hit any key to end the test.
While the test is running, speak into the mouthpiece of the telephone connected to the
DataTalker. If you hear your voice over the speaker, the circuit is okay.
Internal DSU Test
Your internal DSU is in loopback now. The DSU loops both local and remote. To loop data exit
command mode.
To end loopback, reset the unit.
External Device Test
To perform a composite link loopback test, put your external link device into loopback.
Internal MMH2834 Test
To perform a composite link loopback test, go into the composite link configuration menu and
send the command AT&M1U to the modem. Wait for the “Connect” message, then enter q. After
the q, you can exit command mode to loop data.
To end loopback, reset the unit.
80
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
6.6 Configure Remote Unit
Configuration menu option 5 is dependent on the position of DIP switch SW-5. If DIP switch SW-
5 is in the Open (Up) position (MMV8/16/32), the configuration menu allows for the DataTalker to
set parameters to communicate with with other MultiMux products (i.e., MMV800, MMV1600, or
MMV3200 series). If the DIP switch is in the Down (Closed) position (Configure Remote Unit),
the local unit can display and change the configuration of the remote unit. The default for this
DIP switch is the Open (Up) position.
When the position of DIP switch SW-5 is in the Down (Default) position, the Configuation menu
appears as follows:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
When the composite link is established with the remote unit, option 5 is selected, and async
mode is enabled, the remote unit’s Main menu appears on the local unit’s monitor. All menus that
appear are from the remote unit. Any changes made affect the remote unit.
6.6.1
MMV8/16/32 Configuration Options
When DIP switch SW-5 is in the Open (up) position, the Configuration menu appears as follows:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
If option 5 is selected, the MMV8/16/32 menu is displayed and the source and destination nodes
and the source and destination channels can be selected.
MMV8/16/32 Configurations Options
1 - Unit Source Node
:00
:01
:01
:01
:01
:01
2 - Data Destination Node
3 - Data Source Channel
4 - Data Destination Channel
5 - Voice/Fax Ch. 1 Dest. Node
6 - Voice/Fax Ch. 2 Dest. Node
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
81
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
The Unit Source Node option specifies the node number of the local node. This number has to
be unique and any number from 0 to 9. Remember that the node number will be used by other
nodes.
The Data Destination Node option specifies the node number of the remote node. This number
has to be unique and any number from 0 to 9.
The Data Source Channel option specifies the source channel to which the destination channel
is communicating with. The Data Source Channel options are 1 or 2 and the default is 1.
The Data Destination Channel option specifies the destination channel to which the source
channel is communicating with. The Data Destination Channel options are 1 or 2 and the default
is 1.
The Voice/Fax Ch. 1 Destination Node option specifies the node number of the remote node for
Voice/Fax channel 1. This number must be unique and any number from 0 to 9. The default for
this option is 1.
The Voice/Fax Ch. 2 Destination Node option specifies the node number of the remote node for
Voice/Fax channel 2. This number must be unique and any number from 0 to 9. The default for
this option is 1.
6.6.2
Quick Setup
The Quick Setup option (Option 6 in the main menu) allows you to configure your DataTalker by
answering a few questions and then following a set of installation instructions. The following
description
Warning: The memory test will destroy all stored configurtions.
Do you wish to continue (y/n)?
If you answer Yes to this question, the next question is presented. If you answer No to this
question, you are returned to the Main Menu.
Is this a home/small office application? (Y/N/Q)
If you answer Yes to this question, the next question is presented.
Will this unit be installed at the main office? (Y/N/Q)
If you answer Yes to this question, the uint is configured for a main office application and
installation instructions are presented for cabling your unit. Refer to Table 6-1 for the main office
cabling procedure.
If you answer No to this question, the next question asks you:
Enter the number to dial the main office:
You need to enter a 7-digit telephone number if you are using the public telephone service. You
do not need to add a hyphen between the first three digits and the last four digits. If you are
interPBX, you need to enter only the 4-digit number. When the telephone number is entered, the
unit will configure itself based on your input and the installation instructions will be presented to
cable your unit. Refer to Table 6-2 for home office cabling procedure.
82
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
Table 6-1. Main Office Installation
Step
Procedure
1 Voice/Fax - Plug an analog PBX extension into the FXO jack on the back of the Data Talker.
VOICE/FAX CHANNEL
2
DATA/COMMAND
RS232C/V.35
FXO
FXS
DIGITAL
DSU
LEASED
DIAL-UP
MODEM
VOICE/FAX CHANNEL
1
EXTERNAL COMPOSITE
0
1
VOICE/FAX
CHANNEL 1
FXO Connector
RJ11 Phone
Cable
Table 6-1. Main Office Installation
2
Composite Link - Plug the dial up phone line into the dial-up jack on the back of the Data
Talker.
MMH2834 Modem Dial-up
RJ-11 Phone Cable
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal Modem
DIAL-UP Connector
MMH2834 Modem Leased Line
RJ-11 Phone Cable
VOICE/FAX CHANNEL
2
DATA/COMMAND
RS232C/V.35
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal Modem
LEASED Connector
Digital DSU
RJ-48 Cable
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal DSU/TA
DIGITAL Connector
83
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
3
Data Port - Plug the host computer into the Data/Command port and put dip switch 3 up
(located on the side of the Data Talker).
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
DATA/COMMAND
Connector
RS232 Cable
Configuration and installation is complete.
To view or change the current configurations, select option 1 from the main menu.
Press any key to continue.
Storing parameters.
Resetting unit.
Please wait 10 seconds. Then hit ENTER to display the Main Menu.
84
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6 - Menus
Table 6-2. Home Office Installation
Step
1
Procedure
Voice/Fax - Plug your telephone into the FXS jack on the back of the Data Talker.
RJ-11
Phone
Cable
VOICE/FAX CHANNEL
2
DATA/COMMAND
RS232C/V.35
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
EXTERNAL COMPOSITE
MODEM DSU/TA
INTERNAL COMPOSITE
VOICE/FAX CHANNEL
1
POWER
1
2
3
4
5
6
7
8
9
0
#
*
VOICE/FAX
CHANNEL 1
FXS Connector
2
Composite Link - Plug the dial up phone line into the dial-up jack on the back of the Data
Talker.
MMH2834 Modem Dial-up
RJ-11 Phone Cable
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal Modem
DIAL-UP Connector
MMH2834 Modem Leased Line
RJ-11 Phone Cable
VOICE/FAX CHANNEL
2
DATA/COMMAND
RS232C/V.35
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal Modem
LEASED Connector
Digital DSU
RJ-48 Cable
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
Internal DSU/TA
DIGITAL Connector
85
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
3
Data Port - Plug your PC into the Data/Command port and put dip switch 3 up to exit
command mode and enable data mode (located on the side of the Data Talker).
DATA/COMMAND
GND
E&M
FXO
FXS
DIAL-UP LEASED DIGITAL
RS232C/V.35
EXTERNAL COMPOSITE
MODEM
INTERNAL COMPOSITE
DSU/TA
VOICE/FAX CHANNEL
1
POWER
DATA/COMMAND
Connector
RS232 Cable
Configuration and installation is complete.
To connect to the main office turn the Data Talker off and on. It will call the main office every
time it is powered up.
To view or change the current configurations, select option 1 from the main menu.
Press any key to continue.
Storing parameters.
Resetting unit.
Please wait 10 seconds. Then hit ENTER to display the Main Menu.
86
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
7.1 Introduction
The DataTalker is designed to be easy to operate and maintain. The procedures in this chapter
will help isolate any problem to a specific network component, at which point you will be
instructed to call the appropriate personnel or execute commands to adjust operating conditions.
You are not expected to perform any specific repair procedures on the DataTalker besides
command execution and switch settings.
7.2 Importance of the Composite Link Statistics Report
The Composite Link Statistics report provides information about the operation of your composite
link that can aid you in testing for problems. It can be very valuable when used in conjunction
with analog loopback testing, which tests the DataTalker itself, since it can help identify problems
when the problem source is on the other end of the data line or in the line itself.
Data in the Composite Link Statistics report give information about line failure conditions. Your
Composite Link Statistics report contains the following items:
Composite Link Statistics
Elasped Time
Minutes
: 00 Days 00 Hours 00
Data Blocks Transmitted
Data Blocks Retransmitted
Data Blocks Received
Receive Block Errors
:
:
:
:
0
0
0
0
0
0
0
0
Voice/Fax Blocks Transmitted :
Voice/Fax Blocks Received
Link Alarms
Remote Downs
:
:
:
Comparing Data Blocks Transmitted with Data Blocks Retransmitted (the number of retransmits
needed to get the data through) can indicate a line problem. Comparing Data Blocks Received
with Receive Block Errors can indicate the same problem from the other end of the link. Numbers
that you might encounter could be 10,000 data blocks transmitted (or received) compared to 500
or 1000 retransmits (or receive block errors).
Link Alarms tells you simply that there is some sort of problem on the link. You will find that the
Link Alarms numbers will correspond to the Data Blocks Retransmitted and Receive Block Errors
numbers. Specifically, a Link Alarm means that it has been 10 seconds since the DataTalker has
received an acknowledgment. Normally, three acknowledgments will be received during a 10-
second period.
The Remote Downs entry means that a DataTalker has sent data 30 times and could not get it
through (the link has been broken).
The other entries in the Composite Link Statistics report do not apply to link problems.
88
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
7.3 Test Cables
If you are using the DataTalker internal DSU or MMH2834 modem, there are three test cables
you can use to check out your system. Two DataTalker back-to-back test cables allow you to
connect your two DataTalkers locally before installing them on either end of a phone line. There is
also a composite link loopback cable that you can use with the internal DSU to loop the
DataTalker composite link signal back to itself.
To test the internal DSU back-to-back, connect the DSUs in the two units with the RJ-45 back-to-
back cable, then configure one DSU for internal clocking and the other DSU for external clocking.
Set the speed to the same value on both units. To perform the composite link loopback test,
configure the DSU for internal clocking and use the composite link loopback cable.
To test the internal MMH2834 modem back-to-back, use the RJ-11 back-to-back cable and
configure both modems for 4-wire leased line operation. Configure one modem for originate and
the other modem for answer. Set the speed to the same value on both units and set transmit
level to -10. To test 2-wire leased line operation, substitute a regular RJ-11 cable in place of the
back-to-back cable and reconfigure the modem for 2-wire operation.
If you are using an external synchronous modem for the link communications, refer to its
documentation for testing procedures.
If you have any problems in performing these procedures, contact Multi-Tech’s Technical Support
department for assistance (see Chapter 8).
Test Cable for Internal DSU or MMH2834 Modem
Test Cable
DataTalker
DataTalker
Internal Composite
Connector
Note: Used locally before installation to verify operation of
entire system except composite link.
Composite Link Loopback Cable with Internal DSU
Internal Composite
Connector
Composite Link
Loopback Cable
DataTalker
DataTalker
Figure 7-1. Off-Line Test Modes
89
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
7.4 Troubleshooting Guide
This troubleshooting guide is designed to help you pinpoint the cause of your problem and
correct it as quickly as possible. Because equipment from different manufacturers is typically
involved in multiplexer networks, you may encounter “finger pointing” as to who is at fault. Who is
at fault is not as important as getting you back on line as soon as possible. The intent of this
guide is to indicate the most probable causes of specific error conditions, but, since similar
conditions may have different causes, please keep in mind that this is a guide, not a cookbook,
and you must use your best judgement.
For purposes of troubleshooting, you can divide your mux network into three main parts:
Data Channel
•
•
Sync/async channel device (printer, terminal, PC, etc.)
Channel communications (RS232 cabling, modems, etc.)
Voice/Fax Channel
•
•
•
Telephones and fax machines
Station side of PBX
E&M trunk of PBX (channel 1 only)
Composite Link
•
Digital composite link communications line with internal or external DSU or ISDN terminal
adapter
•
•
Internal/external link modem
Composite link communications line (4-wire non-loaded metallic wire for DSU or 2-wire or 4-
wire lease line or dial-up line for internal or external modem)
Once you have found the probable cause of your problem, refer to the specific manual chapter
for additional help, or contact Multi-Tech Technical Support (see Chapter 8).
90
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
Table 7-1. Command Port Troubleshooting
Problem
Possible Causes
Solution
Command port device not
communication with DataTalker
Communications software not
installed on command port PC
1. Install communications
software on command port PC
(refer to communcations
software documentation of
installation instructions).
1. Set DIP-Switch #3 to the
closed (down) position.
Command port not enabled
1. Check RS-232 cable
connections between
command port device and
Command port on DataTalker
for loose connections or bent
pins.
Bad cable or cable connection
2. Check RS-232 cable
connections between
command port device and
Command port on DataTalker
for correct cable wiring (see
cabling diagrams in Appendix
C).
3. Call Tech Support for
assistance (see Chapter 8).
Table 7-2. Composite Link Troubleshooting Internal DSU
Problem
Possible Causes
Solution
Composite link down with CTS,
XMT, and RD LED on
DSU not communication with
communication line
Verify that the DSU LED is on. If
off, ensure that DIP-Switch #2 is in
the open (up) position.
Verify that a cable is connected to
the internal composite DSU/TA
Digital connector.
Verify DSU configuration. See
Composite Link Settings - Internal
DSU in Table 7-5.
Call Tech Support for assistance
(see Chapter 8).
Faulty communication line
Call phone company and verify
communication line.
Call Tech Support for assistance
(see Chapter 8).
91
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Table 7-2. Composite Link Troubleshooting Internal DSU
Problem
Possible Causes
Solution
Composite link down with CD,
CTS, XMT, RD and RCV LEDs
on
Composite link not configured
correctly
1. Verify DSU configuration. See
Composite Link settings -
Inernal DSU in Table 7-5.
2. Call Tech Support for
assistance (see Chapter 8).
High error rate on communication
line
1. View composite link statistics
(refer to Table 7-10).
Flashing RXT LED
2. Perform composite link
loopback tests (refer to Table
7-12).
3. Call phone company and
verify communication line.
4. Call Tech Support for
assistance (see Chapter 8).
1. For DDS line, both DSUs
should be set for DDS
clocking.
DSU clocking configured
incorrectly
2. Call phone company and
verify communication line.
3. Call Tech Support for
assistance (see Chapter 8).
92
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
Internal ISDN Terminal Adapter
Problem
Possible Causes
Solution
Composite link down with CTS,
XMT and RD LEDs on
Terminal adapter not
communicating with ISDN line
1. Verify that the the TA LED is
on. If off, ensure that DIP-
Switch #2 is set to OPEN
(Up).
2. Verify that a cable is
connected to the internal
composite DSU/TA Digital
connector.
3. Verify ISDN configuration. See
Composite Link Settings -
Internal ISDN in Tabe 7-6.
4. Call Tech Support for
assistance (see Chapter 8).
1. Call phone company and
verify communication line.
Faulty communication line
2. Call Tech Support for
assistance (see Chapter 8).
Composite link down with CD,
CTS, XMT, RCV and RD LEDs
on
1. Verify ISDN configuration, See
Composite Link Settings -
Composite link not configured
correctly
Internal ISDN in Table 7-6.
2. Call Tech Support for
assistance (see Chapter 8).
1. View composite link statistics
(refer to Table 7-9).
Flashing RXT LED
High error rate on communication
line
2. Perform composite link
loopback tests (see
Diagnostic Testing in Table 7-
12).
3. Call phone company and
verify communication line.
4. Call Tech Support for
assistance (see Chapter 8).
ISDN clocking configured
incorrectly
1. For ISDN line, both terminal
adapters should be set for
normal clock source.
2. Call Phone company and
verify communication line.
3. Call Tech Support for
assistance (see Chapter 8).
93
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Internal MMH2834 Modem
Problem
Possible Causes
Solution
Composite link down with CTS,
XMT, and RD LEDs on
MMH2834 modem not
communicating with
communications line
1. Verify MDM LED is on. If off,
ensure that DIP-Switch #2 is
in the OPEN (Up) position.
2. Verify that cables are
connected to internal
composite Modem Dial-up or
Leased connector.
3. Verify modem configuration
(see Composite Link Settings
- Internal MMH2834 in Table
7-7).
4. Perform Local Analog
Loopback test (see Appendix
G, “Testing your MMH2834”).
5. Call Tech Support for
assistance (see Chapter 8).
1. Call phone company and
verify communication line.
Faulty communications line
2. Call Tech Support for
assistance (see Chapter 8).
1. Verify modem configuration
(see Composite Link Settings
- Internal MMH2834 in Table
7-7).
Composite link not configured
correctly
Composite link down with CD,
CTS, XMT, RCV and RD LEDs
on
2. Call Tech Support for
assistance (see Chapter 8).
1. View composite link statistics
(refer to Table 7-9).
High error rate on communication
line
Flashing RXT LED
2. Perform Local Analog
Loopback test (see Appendix
G, “Testing your MMH2834”).
3. Call phone company and
verify communication line
4. Call Tech Support for
assistance (see Chapter 8).
94
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
External Composite Link Device
Problem
Possible Causes
Solutions
Composite link down with CTS,
XMT and RD LEDs on
Composite link not communicating 1. Verify EXT LED is on. If off,
with communications line
ensure that DIP-Switch #2 is
in the Closed (down) position.
2. Verify that calbe is connected
to External Composite
RS232C/V.35 connector.
3. Verify composite link
configuration (see Composite
Link Settings - External
Device in Table 7-8).
Faulty communications line
1. Call phone company and
verify communication line.
2. Call Tech Support for
assistance (see Chapter 8).
Composite link not configured
correctly
Composite link down with CD,
CTS, XMT, RCV and RD LEDs
on
1. Vereify composite link
configuration (see Composite
Link Settings - External
Device in Table7-8).
Flashing RXT LED
1. View composite link statistics
(refer to Table 7-9)
High error rate on communication
line
2. Perform composite link
loopback tests (see
Diagnostic Testing in Table 7-
12).
3. Call phone company and
verify communication line.
4. Call Tech Support for
assistance (see Chapter 8).
Composite link down with CD,
CTS and RD LEDs on
External device settings
1. Verify that external device is
set for sync, full duplex, and
internal clocking.
95
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Table 7-3
Data Channel Troubleshooting
Problem
Possible Causes
Solution
Async Data Channel
Channel Device not
Incorrect channel parameter
1. Verify configuration of data
port (see Data Port
communicating with DataTalker; settings
composite link up with CD,,
CTS, XMT, RCV and RD LEDs
on
Configuration in Table 7-10).
2. Call Tech Support for
assistance (see Chapter 8).
Channel device incorrectly cabled
1. See cabling diagrams in
Appendix B and C on both
DataTalker and data channel
device.
2. Call Tech Support for
assistance (see Chapter 8).
Flow control not properly set
Async Data Channel device
losing data
1. Verify flow control options for
the async data channel device
(see Table 7-10).
Sync Data Channel
Channel Device not
1. Verify configuration of data
port (see Data Port
Incorrect channel parameter
settings
communicating with DataTalker;
composite link up with CD,,
CTS, XMT, RCV and RD LEDs
on
Configuration in Table 7-10).
2. Call Tech Support for
assistance (see Chapter 8).
1. See cabling diagrams in
Appendix B and C on both
DataTalker and data channel
device.
Channel device incorrectly cabled
2. Call Tech Support for
assistance (see Chapter 8).
Incorrect Data Type
Incorrect Clocking
1. Verify that sync device uses
HDLC or SLDC protocol, NRZ
encoding, and operates in full
duplex.
1. If sync device expects clock to
come from DataTalker on pins
15 and 17, set DataTalker
sync data channel to internal
clocking and set speed.
2. If sync device provides click to
DataTalker on pin 24,
confiugre sync data channel
for external clocking.
96
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
Table 7-4. Voice/Fax Troubleshooting
Problem
Possible Causes
Solution
Volume levels not sufficient on
local voice/fax channel
Input level gain setting too low on
remote voice/fax channel
1. Increase input level gain
setting on remote voice/fax
channel a couple db and
recheck voice quality (see
Table 7-11).
Local telephone goes off-hook
and remote telephone does not
ring (FXS to FXS configuration)
Output level attentuation setting
too high on local voice/fax channel
1. Decrease output level
attentuation setting on local
voice/fax channel a couple of
db and recheck voice quality
(see Table 7-11).
Device not connected to correct
voice/fax connector
1. Verify that devices are
attached to voice/fax channel
FXS RJ-11 connector.
Voice/fax channel configuration
problem
1. Verify that local and remote
interface types are configured
correctly (see Table 7-11).
2. Obsereve that the XSG LED
on the local voice/fax channel
lights when the telephone
goes off-hook and that the
RSG LED on the remote FXS-
configured voice/fax channel
flashes with each ring.
Data throughput slows
excessively when voice/fax
channel is active
Too much bandwidth being used
up for voice/fax
1. Decrease voice/fax channel
digitizing rate to 9600 bos
(see Table 7-11).
2. Enable or, if active, increase
silence suppression on voice/
fax channel (see Table 7-11)
FXO to FXO configuration -
local telephone does not ring
1. Verify that the device is
attached to the correct voice/
fax channel RJ-11 connector.
Device not connected to correct
voice/fax connector
1. Verify that local voice/fax
interface type is configured for
FXS and remote interface
type is set for FXO operation
(see Table 7-11).
Voice/fax channel configuration
problem
Parts of words are not being
heard
1. Lower the input level gain and
the output level attentuation a
couple of db and recheck
Part of analog signal being clipped
off
voice quality (see Table 7-11).
97
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Table 7-4. Voice/Fax Troubleshooting (continued)
Problem
Possible Causes
Solution
Voice conversation or fax traffic Remote connection is different
1. Contact the remote site to
verify its local interface type
and ensure that remote
becomes erratic after changing
the remote interface type
from remote interface type
interface type at local site is
the same (see Table 7-11).
No communication on voice/fax
channel
Composite link down
1. Call phone company and
verify communication line.
1. Verify that the phone cord for
the voice or fax machine is
connected to the correct
interface connector.
Phone cord for the voice or fax
machine is connected to the
wrong interface connector
98
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
7.5 Composite Link Settings - Internal DSU
Table 7-5. Composite Link Settings - Internal DSU
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
7
Enter 3 and press ENTER to display the Composite Link Settings - Internal DSU menu.
Verify the internal DSU settings. To change settings, enter the appropriate option numbers.
The default settings are correct for a 56K bps DDS line.
Composite Link Settings
-
Internal DSU
1
2
S
M
P
-
-
-
-
-
Speed:
56k
DDS
Clocking:
Store All Configurations
Main Menu
Previous Menu
Selection
:
_
8
9
When all options for the DSU are set, enter S and press ENTER to store all configurations.
Then enter M and press ENTER to return to the Main Menu.
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port to a data channel.
99
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
7.6 Composite Link Settings - Internal ISDN Terminal
Adapter
Table 7-6. Composite Link Settings - Internal ISDN Terminal Adapter
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
7
Enter 3 and press ENTER to display the Composite Link Settings - Internal TA menu.
Select option 2, Configure TA, from the menu to verify the terminal adapter settings. After you
select the option, wait five seconds, then enter AT!V to access the terminal adapter’s
configuration menu. To change a setting, enter the menu choice number and press ENTER.
For further information refer to the ISDN Terminal Adapter Owner’s Manual.
Composite Link Settings - Internal TA
1 - On-Line XMT Rate:
2 - Configure TA
128000
Off
3 - DOD/DOI:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
8
9
When you are done configuring the terminal adapter, enter CTRL+X to exit the terminal
adapter’s configuration menu; then press ENTER, Q to return to the DataTalker’s Composite
Link Settings - Internal TA menu, and press M, ENTER to return to the Main menu.
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port to a data channel.
100
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
7.7 Composite Link Settings - Internal Modem
Table 7-7. Composite Link Settings - Internal MMH2834
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
7
Enter 3 and press ENTER to display the Composite Link Settings - Internal MMH2834 menu.
Verify the internal MMH2834 modem settings. To change settings, enter the appropriate
option numbers.
Composite Link Settings - Internal MMH2834
1
2
3
4
5
6
7
8
9
- Enter AT commands to 2834
- On-Line XMT Rate:
- Speed Setting:
28800
33600
Dial
2 Wire
Answer
-10db
On
03min
40sec
-
Dial/Leased:
- 2 or 4 Wire:
-
Answer/Originate:
- Transmit Level
- DOD/DOI:
- DOI Timer:
10 - DOD Toggle DTR:
S
M
P
- Store All Configurations
- Main Menu
- Previous Menu
Selection : _
8
9
When all options for the port and modem are set, enter S and press ENTER to store all
configurations. Then enter M and press ENTER to return to the Main Menu.
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port over to a data channel.
101
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
7.8 Composite Link Settings - External Device
Table 7-8. Composite Link Settings - External Device
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
7
Enter number 3 from the configurations menu and press ENTER to display the Composite
Link Settings - External Device menu.
Verify the external device settings. To change settings, enter the appropriate option numbers.
Composite Link Settings -External Device
1 - On-Line XMT Rate:
2 - Clocking:
56000
External
Off
3 - Back to Back:
4 - DOD/DOI:
On
5 - DOI Timer:
03min
40sec
6 - DOD Toggle DTR:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
8
9
When all the options for the external device are set, enter S and press ENTER to store all
configurations. Then enter M and press ENTER to return to the Main Menu.
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port over to a data channel.
102
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
7.9 Composite Link Statistics
Table 7-9. Composite Link Statistics
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 2 and press ENTER. The Statistics menu is displayed:
Statistics
1 - View Composite Link Statistics
2 - Clear Composite Link Statistics
M - Main Menu
P - Previous Menu
Selection : _
6
Enter 1 and press ENTER to view the composite link statistics:
Composite Link Statistics
Elasped Time
Minutes
: 00 Days 00 Hours 00
Data Blocks Transmitted
Data Blocks Retransmitted
Data Blocks Received
Receive Block Errors
:
:
:
:
0
0
0
0
0
0
0
0
Voice/Fax Blocks Transmitted :
Voice/Fax Blocks Received
Link Alarms
Remote Downs
:
:
:
103
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
7
Comparing Data Blocks Transmitted with Data Blocks Retransmitted (the number of
retransmits needed to get the data through) can indicate a line problem. Comparing Data
Blocks Received with Receive Block Errors can indicate the same problem from the other
end of the link. Numbers that you might encounter could be 10,000 data blocks transmitted
(or received) compared to 500 or 1000 retransmits (or receive block errors).
Link Alarms tells you simply that there is some sort of problem on the link. You will find that
the Link Alarms numbers will correspond to the Data Blocks Retransmitted and Receive
Block Errors numbers. Specifically, a Link Alarm means that it has been 10 seconds since
the DataTalker has received an acknowledgment. Normally, three acknowledgments will be
received during a 10-second period.
The remote down entry means that the DataTalker has sent data 30 times and could not get
it through (the link has been broken).
The other entries do not apply to link problems.
8
9
Enter M and press ENTER to return to the Main Menu.
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port over to a data channel.
104
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
7.10Data Port Configuration
Table 7-10. Data Port Configuration
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
Enter 1 and press ENTER to display the Data Port Configuration menu.
Data Port Configuration
1
2
3
4
5
6
7
8
9
- Async/Sync:
- Speed:
- Word Length:
- Stop Bits:
- Parity:
Async
19200
8
1
None
CTS
Off
Off
Off
Off
Off
- Flow Control:
- Enq/Ack Flow Control:
- Echo:
- Pacing:
10 - EIA Pass Through:
11 - Pass Xon:
S
M
P
- Store All Configurations
- Main Menu
- Previous Menu
Selection : _
105
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
7
If the data port is set up as an asynchronous data channel, you should verify all 12 options.
Data Port Configuration
1 - Async/Sync:
2 - Speed:
Sync
19200
Internal
Flags
NRZ
3 - Clocking:
4 - Idle Condition:
5 - NRZ/NRZI Encoding:
6 - CRC Preset:
7 - Inter-frame Timer:
S - Store All Configuations
M - Main Menu
P - Previous Menu
Selection : _
All 1s
Off
If the data port is set up as a synchronous data channel, the sync parameters are displayed.
8
9
When you have verified or set all options for the data port, enter S and press ENTER to store
all configurations. Then enter M and press ENTER to return to the Main Menu.
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the data/command port to a data channel.
106
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
7.11Voice/Fax Channel Configuration
Table 7-11. Voice/Fax Channel Configuration
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
Enter 2 and press ENTER. If two voice/fax channels are installed in the DataTalker, the
Voice/Fax Channel Configuration menu will appear. Enter 1 to display the Voice/Fax Channel
1 Configuration menu, or 2 to display the Voice/Fax Channel 2 Configuration menu. If only
one voice/fax channel is installed, the Voice/Fax Channel 1 Configuration menu will appear in
place of the Voice/Fax Channel Configuration menu.
107
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Voice/Fax Channel 1 Configuration
1 - Destination Channel
2 - Digitizing Rate
3 - Output Level Atten.
4 - Input Level Gain
5 - Silence Suppression
6 - Local Interface Type
: 1
: 9600
: 12
: 03
: Off
: FXS
7 -
8 -
9 -
10 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
Dialtone/Wink (E&M)
Wink Timer (E&M)
: N/A
: N/A
: N/A
: FXS
11 - Remote Interface Type
12 -
13 -
14 -
Ground/Loop Start (FXS) : Loop
2 or 4 Wire (E&M)
: N/A
: N/A
Dialtone/Wink (E&M)
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
7
Verify the voice/fax channel configuration. To change the configuration, enter the appropriate
option numbers.
Options 1 through 10 are for the local interface. Options 11 through 14 are for the remote
interface. Note that the remote interface options do not actually change the remote interface;
they only tell the local DataTalker how the remote interface is configured. Any changes in the
remote interface must be done at the remote site. See Chapter 6 for descriptions of the
Voice/Fax Channel 1 Configuration menu options.
8
9
When all the options for the voice/fax channel are set, enter S and press ENTER to store all
configurations. Then enter M and press ENTER to return to the Main Menu.
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port over to a data channel.
108
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7 - Troubleshooting
7.12Diagnostic Testing
Table 7-12. Diagnostic Testing
Step
Procedure
1
2
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
4
Apply power to the DataTalker.
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 4 and press ENTER. The Diagnostics menu is displayed:
Diagnostics
1 - Loop Test
2 - Memory Test
3 - Watch Dog Test
4 - Dip Switch Definitions and Settings
5 - Product and Firmware ID
M - Main Menu
P - Previous Menu
Selection : _
6
Select the test you wish to run by entering its option number and pressing ENTER.
If you select Loop Test, the Loop Test menu will appear.
109
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
110
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8 - Warranty, Service and Tech Support
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
8.1 Introduction
This chapter begins with your DataTalker’s 2-year warranty. Read carefully the next section,
“Tech Support,” if you have questions about or problems with your DataTalker. It includes the
technical support telephone numbers, space for recording your product information, and an
explanation of how to send in your DataTalker should you require service. The final three
sections explain how to use our bulletin board service (BBS), and get support through
CompuServe and the Internet.
8.2 Limited Warranty
Multi-Tech Systems, Inc. (“MTS”) warrants that its products will be free from defects in material or
workmanship for a period of two years from the date of purchase, or if proof of purchase is not
provided, two years from date of shipment. MTS MAKES NO OTHER WARRANTY,
EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. This warranty does
not apply to any products which have been damaged by lightning storms, water, or power surges
or which have been neglected, altered, abused, used for a purpose other than the one for which
they were manufactured, repaired by the customer or any party without MTS’s written
authorization, or used in any manner inconsistent with MTS’s instructions.
MTS’s entire obligation under this warranty shall be limited (at MTS’s option) to repair or
replacement of any products which prove to be defective within the warranty period, or, at MTS’s
option, issuance of a refund of the purchase price. Defective products must be returned by
Customer to MTS’s factory transportation prepaid.
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES AND UNDER NO
CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PURCHASE PRICE FOR DEFECTIVE
PRODUCTS.
8.2.1
On-line Warranty Registration
To register your DataTalker on-line, click on the following link:
112
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8 - Warranty, Service and Tech Support
8.3 Tech Support
Multi-Tech has an excellent staff of technical support personnel available to help you get the most
out of your Multi-Tech product. If you have any questions about the operation of this unit, call 1-
800-972-2439. Please fill out the DataTalker information form below and have it available when
you call. If your DataTalker requires service, the tech support specialist will guide you on how to
send it in (see section 8.3.2).
8.3.1
Recording DataTalker Information
Please fill in the following information on your Multi-Tech DataTalker. This will help Tech Support
in answering your questions. (The same information is requested on the Warranty Registration
Card.)
Model Number:
Serial Number:
Firmware Version:
The model and serial numbers are on the bottom of your DataTalker. The Diagnostic Test menu
displays the PROM firmware version number.
Before calling Tech Support, please note in the space below if an internal DSU, modem, or ISDN
terminal adapter has been added to your DataTalker. Also note status information about your
DataTalker, including LED indicators, screen messages, diagnostic test results, DIP switch
settings, problems with a specific application, etc.
8.3.2
Service
If your tech support specialist decides that service is required, your DataTalker may be sent
(freight prepaid) to our factory. Return shipping charges will be paid by Multi-Tech Systems.
Note: Before returning your DataTalker for service, record your data port configuration and voice/
fax channel configurations. When the DataTalker is returned to you, the configurations are reset
to the factory defaults.
Include the following with your DataTalker:
•
•
•
•
A description of the problem.
Return billing and shipping addresses.
Contact name and phone number.
Check or purchase order number for payment if the DataTalker is out of warranty. (Check
with your technical support specialist for the standard repair charge for your DataTalker).
•
If possible, note the name of the technical support specialist with whom you spoke.
If you need to inquire about the status of the returned product, be prepared to provide the serial
number of the product sent (see section 8.3.1).
Send DataTalkers to this address:
MULTI-TECH SYSTEMS, INC.
2205 WOODALE DRIVE
MOUNDS VIEW, MINNESOTA 55112
ATTN: SERVICE OR REPAIRS
You should also check with the supplier of your DataTalker on the availability of local service and/
or loaner units in your part of the country.
113
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
8.4 The Multi-Tech BBS
For customers who do not have Internet access, Multi-Tech maintains a bulletin board system
(BBS) that mirrors its FTP site. Information available from the BBS includes new product
information, product upgrade files, and problem-solving tips. The phone number for the Multi-
Tech BBS is (800) 392-2432 (USA and Canada) or (612) 785-3702 (international and local).
The BBS can be accessed by any asynchronous modem operating at 1200 bps to 33,600 bps at
a setting of 8 bits, no parity, and 1 stop bit (8-N-1).
To log on to the Multi-Tech BBS
1. Set your communications program to 8-N-1.
2. Dial our BBS at (800) 392-2432 (USA and Canada) or (612) 785-3702 (international and
local).
3. At the prompts, type your first name, last name, and password; then press ENTER. If you are
a first time caller, the BBS asks if your name is spelled correctly. If you answer yes, a
questionnaire appears. You must complete the questionnaire to use the BBS on your first
call.
4. Press ENTER until the Main Menu appears. From the Main Menu you have access to two
areas: the Files Menu and News. For help on menu commands, type ?.
To Download a file
If you know the file name:
1. From the Main Menu, type F to access the Files Menu, then type D.
2. Enter the name of the file you wish to download from the BBS.
3. If a password is required, enter the password.
4. Answer Y or N to the automatic logoff question.
5. Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (the
recommended protocol).
6. If you select Zmodem, the transfer will begin automatically. If you select another protocol, you
may have to initiate the transfer yourself. (In most datacomm programs, the PAGE DOWN
key initiates the download.)
7. When the download is complete, press ENTER to return to the File Menu.
8. To exit the BBS, type G and press ENTER.
If you don’t know the file name:
1. From the Main Menu, type F to access the Files Menu. For a list of file areas, type L, press
ENTER, then type L and press ENTER again. (If you do not type the second L, you will list all
of the files on the BBS.)
2. Mark each file area you would like to examine by typing its list number and pressing ENTER.
3. Enter L to list all the files in the selected file areas. Enter C to go forward in the file list and P
to go back.
4. To mark one or more files for download, type M, press ENTER, type the list numbers of the
files, and press ENTER again.
5. Enter D. You will see a list of the files you have marked. Enter E if you would like to edit the
list; otherwise enter D again to start the download process.
114
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8 - Warranty, Service and Tech Support
6. Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (the
recommended protocol).
7. If you select Zmodem, the file will transfer automatically. If you select another protocol, you
may have to initiate the transfer yourself. (In most data communications programs, the PAGE
DOWN key initiates the download.)
8. When the download is complete, press ENTER to return to the File Menu.
9. To exit the BBS, type G and press ENTER.
8.5 About the Internet
Multi-Tech is a commercial user on the Internet, and we retrieve messages from our customers
on a periodic basis. If you prefer to receive technical support via the Internet, you can contact
Tech Support at the following address:
Multi-Tech’s presence includes a Web site at:
and an ftp site at:
115
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
116
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendixes
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Appendix A - ASCII Conversion Chart
CTRL CODE HEX DEC
CODE HEX DEC CODE HEX DEC CODE HEX DEC
@
A
B
C
D
E
F
G
H
I
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
0
1
SP
!
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
@
A
B
C
D
E
F
G
H
I
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
`
a
b
c
d
e
f
g
h
i
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
96
97
2
“
98
99
3
#
$
%
&
‘
4
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
5
6
7
8
(
HT
9
)
J
LF
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
*
J
j
k
l
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
VT
+
,
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
FF
CR
-
m
n
o
p
q
r
SO
.
SI
/
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
0
1
2
3
4
5
6
7
8
9
:
s
t
u
v
w
x
y
z
SUB
ESC
FS
;
{
\
<
=
>
?
\
|
]
GS
]
}
^
RS
^
~
DEL
_
US
_
NUL Null, or all zeros
SOH Start of header
STX Start of text
ETX End of text
EOT End of transmission
ENQ Enquiry
ACK Acknowledge
BEL Bell or alarm
BS Backspace
VT
FF
Vertical tab
Formfeed
SYN Synchronous idle
ETB End transmission block
CAN Cancel
EM End of medium
SUB Substitute
ESC Escape
CR Carriage return
SO Shift out
SI
DLE Data link escape
DC1 Device control 1
DC2 Device control 2
DC3 Device control 3
DC4 Device control 4
NAK Negative acknowledge
Shift in
FS
File separator
GS Group separator
RS Record separator
US Unit separator
DEL Delete
HT Horizontal tab
LF
Linefeed
118
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B - RS-232C Interface Specification
Appendix B - RS-232C Interface Specification
The DataTalker's RS232C interface circuits have been designed to meet the electrical
specifications given in the EIA (Electronic Industries Association) RS232C and ITU-T
(International Telecommunications Union) V.24 standards. All signals generated by the
DataTalker are approximately 10 volts when measured across a load of 300 ohms or greater. The
receiving circuits of the DataTalker will accept signals in the 3 to 25 volt range. The voltage
thresholds are:
Negative
Positive
=
=
voltage more negative than -3 volts with respect to signal ground.
voltage more positive than +3 volts with respect to signal ground.
SIGNAL INFORMATION:
NEGATIVE
POSITIVE
Binary State
Signal Condition
Control and Timing Function
One
Mark
Off
Zero
Space
On
The input impedances of all DataTalker circuits which accept signals from the data processing
terminal or CPU equipment have DC resistances of 4.7K. For more specific details, consult the
EIA RS232C standard itself.
The following chart lists the EIA RS232C interface pins and circuits present on the DataTalker’s
RS232C connector. All other pins are unused. The composite side of the DataTalker is configured
as a DTE device and the channel sides are DCE devices.
PIN
MULTI-TECH EIA
CCITT
SIGNAL
CIRCUIT
ASS
DESIG
CIRCUIT
CIRCUIT
SOURCE*
FUNCTION
2
SD
BA
BB
CA
CB
CC
AB
CF
+V
DB
DD
CD
CE
DA
CN
103
104
105
106
107
102
109
--
DTE
DCE
DTE
DCE
DCE
——
DCE
DCE
DCE
DCE
DTE
DCE
DTE
DTE
Transmitted Data
Received Data
Request to Send
Clear to Send
3
RD
4
RTS
CTS
DSR
SG
5
6
Data Set Ready
Signal Ground
7
B
CD
Data Carrier Detector
Test Voltage
9
+V
15
17
20
22
24
25
TC
114
115
108/2
125
113
142
Transmit Clock
Receive Clock
RC
TR
Data Terminal Ready
Ring Indicator
Rl
XTC
OOS
External Transmit
Terminal Busy
*DTE
DCE
=
=
Data Terminal Equipment
Data Communications Equipment
The computer should be supplied with a cable terminated with a Cinch DB25P (or equivalent)
connector mounted in a Cinch DB51226-1 (or equivalent) hood assembly as specified by the
RS232C/V.24 standard.
119
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Appendix C - Cabling Diagrams
Channel Cables
DCE to Channel Cabling
(with EIA pass-through)
PIN NO.
PIN NO.
1
1
CHASSIS GROUND (AA)
TRANSMIT DATA (BA)
RECEIVE DATA (BB)
2
2
3
3
To
DCE
Device
(Data
Communications
Equipment,
i.e., Modem)
4
4
REQUEST TO SEND (CA)
CLEAR TO SEND (CB)
DATA SET READY (CC)
SIGNAL GROUND (AB)
CARRIER DETECT (CF)
DATA TERMINAL READY (CD)
RING INDICATOR (CE)
OUT OF SERVICE/BUSY
5
5
To
6
6
DATA/COMMAND
Connector
7
7
8
8
20
22
25
20
22
25
DCE to Channel cabling
(without EIA pass-through)
PIN NO.
PIN NO.
1
1
CHASSIS GROUND (AA)
TRANSMIT DATA (BA)
RECEIVE DATA (BB)
2
2
3
3
To
DCE
Device
(Data
Communications
Equipment,
i.e., Modem)
4
4
REQUEST TO SEND (CA)
CLEAR TO SEND (CB)
DATA SET READY (CC)
SIGNAL GROUND (AB)
CARRIER DETECT (CF)
DATA TERMINAL READY (CD)
RING INDICATOR (CE)
OUT OF SERVICE/BUSY
5
5
To
6
6
DATA/COMMAND
Connector
7
7
8
8
20
22
25
20
22
25
DTE to Channel cabling
PIN NO.
PIN NO.
1
1
CHASSIS GROUND (AA)
TRANSMIT DATA (BA)
RECEIVE DATA (BB)
2
2
3
3
To
DTE
Device
(Data Terminal
Equipment,
i.e., Computer
Terminal)
4
4
REQUEST TO SEND (CA)
CLEAR TO SEND (CB)
DATA SET READY (CC)
SIGNAL GROUND (AB)
CARRIER DETECT (CF)
DATA TERMINAL READY (CD)
5
5
To
6
6
DATA/COMMAND
Connector
7
7
8
8
20
22
25
20
22
25
120
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C - Cabling Diagrams
Composite Link Cabling
RS232C/V.24 Configured Composite Link*
PIN NO.
PIN NO.
1
1
CHASSIS GROUND (AA)
TRANSMIT DATA (BA)
RECEIVE DATA (BB)
2
2
3
3
To
External
Synchronous
Modem/DSU/
Terminal Adapter
Connector
4
4
REQUEST TO SEND (CA)
CLEAR TO SEND (CB)
SIGNAL GROUND (AB)
CARRIER DETECT (CF)
TRANSMIT CLOCK (DB)
RECEIVE CLOCK (DD)
5
5
To DataTalker
RS232C/V.35
Connector
7
7
8
8
15
17
20
25
15
17
20
25
DATA TERMINAL READY (CD)
V.35 Adapter Cable Configured on a
RS232C/V.35 Composite Link**
V.35 34-PIN
CONNECTOR (MALE)
25-PIN
CONNECTOR (FEMALE)
A
B
1
PROTECTIVE GROUND
7
SIGNAL GROUND
C
D
E
4
REQUEST TO SEND
CLEAR TO SEND
5
6
DATA SET READY
F
8
DATA CARRIER DETECT
DATA TERMINAL READY
TRANSMIT DATA A
RECEIVE DATA A
H
P
20
2
R
S
3
12
22
23
17
25
18
15
21
TRANSMIT DATA B
RECEIVE DATA B
T
U
V
EXTERNAL TX CLOCK A
RECEIVE CLOCK A
EXTERNAL TX CLOCK B
RECEIVE CLOCK B
TRANSMIT CLOCK A
TRANSMIT CLOCK B
W
X
Y
AA
* The DataTalker RS232C interface circuits have been designed to meet the electrical specifications
given in EIA (Electronic Industries Association) RS232C and ITU-T (International Telecommunications
Union) V.24 Standards.
** When configured for V.35 interface operation on the composite link, the V.35 adapter cable should
be used. This cable uses a 25-pin female connector at one end and a 34-pin Winchester male
connector at the other end.
121
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
RJ-48 Cable for Internal DSU
RT
RR
Receive
Transmit
{
{
RT
RR
1 2 3 4 5 6 7 8
RJ-48 Cable for Internal ISDN Terminal Adapter
T
R
1 2 3 4 5 6 7 8
Back to Back Mux Cable
DB-25 FEMALE
CONNECTOR
DB-25 FEMALE
CONNECTOR
Frame Ground
Transmit Data
Receive Data
Request To Send
Clear To Send
Signal Ground
Data Set Ready
Carrier Detect
Transmit Clock
Receive Clock
1
2
3
4
5
7
6
8
15
17
1
3
2
5
4
Frame Ground (AA)
Receive Data (BB)
Transmit Data (BA)
Clear To Send (CB)
Request To Send (CA)
Signal Ground (AB)
Data Terminal Ready (CD)
7
20
24
Internal Clock
Data Terminal Ready
20
6
8
15
17
Data Set Ready
Carrier Detect
Transmit Clock
Receive Clcok
Internal Clock
24
DTE
DTE
This cable is used to connect two DataTalkers back to back. The cable is asymmetrical and allows
one of the DataTalkers to provide clocking to the TxC and RxC pins of the other DataTalker. Make
sure the composite link configurations of the DataTalkers have one of them set for an internal clock
and the other for an external clock.
122
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C - Cabling Diagrams
E&M Voice/Fax Channel Cable
Green-White
M
E
Input
Output
White-Green
White-Orange
White-Blue
Blue-White
Orange-White
T1 4-Wire Output
R
T
R1 4-Wire Output
SG (Signal Ground) Output
SB (Signal Battery) Output
4-Wire Input, 2-Wire
4-Wire Input, 2-Wire
Brown-White
White-Brown
RJ45 Plug
* Cable wire is solid 24AWG. If connecting to a punch block, spade lugs may be cut off.
RJ45
Wire
Spade Lug
Color
Function
1
2
3
4
5
6
7
8
M
E
T1
R
T
R1
SG
SB
Green/White
White/Green
White/Orange 4-Wire Output
White/Blue
Blue/White
Orange/White 4-Wire Output
Input
Output
4-Wire Input, 2-Wire
4-Wire Input, 2-Wire
Brown/White
White/Brown
(Signal Ground) Output
(Signal Battery) Output
Voice/Fax Channel Connectors
FXO
FXS
E&M
12345678
2345
2345
VOICE/FAX CHANNEL 1
Pin Connections
E&M
Description
FXO
Description
FXS
Description
1
2
3
4
5
6
7
8
M
E
T1
R
T
R1
SG
SB
2
3
4
5
N/C
Ring
Tip
2
3
4
5
N/C
Tip
Ring
N/C
N/C
DSU Back-to-Back Cable
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
RJ-48 Plug
RJ-48 Jack
123
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Appendix D - Flow Control Background
Flow control refers to techniques used by computer devices and the DataTalker to stop and
restart the flow of data between them. Flow control prevents a channel device or DataTalker from
receiving more data than it can handle. Flow control initiated by the DataTalker is called
DataTalker-initiated flow control. It might be needed, for instance, if a DataTalker is connected to
a minicomputer that can output more data than the DataTalker can handle. Flow control by the
channel device is called channel device-initiated pacing. Pacing might be required, for instance,
by a printer channel device that cannot print data as fast as the DataTalker can send it, or which
may need to go off-line when it runs out of paper. To state it simply, flow control is something the
DataTalker does to the channel device, while pacing is something the channel device does to the
DataTalker.
DATATALKER-INITIATED
FLOW CONTROL
CHANNEL DEVICE-
INITIATED PACING
DATA
DATA
Channel
DataTalker
Device
Channel
Device
DataTalker
Flow control stops the input
of data to the DataTalker
Pacing stops the output of
data from the DataTalker
Flow control can be software or hardware based. In software flow control, special characters
(XON and XOFF) are used to stop and start the flow of data. In hardware flow control the Clear
To Send (CTS) signal on the RS-232C interface (pin 5) is brought low to stop data and high to
restart it. When you select a flow control method with a DataTalker command you are also
selecting the corresponding pacing method.
124
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix E - MMH2834 Modem S-Registers
Appendix E - MMH2834 Modem S-Registers
Introduction
This section describes the MMH2834 memory locations called S-registers, where certain
MMH2834 modem configurations are stored. Each S-register is assigned a number (S0, S1, S2,
etc.). Use the S command to read and/or change the value stored in an S-register (ATSr? to read
and ATSr= to change S-register values).
S0
Number of Rings Until Modem Answers
Unit:
Range:
Default:
1 count
0–255
1
Description: S0 defines the number of rings the modem waits before answering an incoming
call. The default value is one ring, which means that the modem answers the call immediately
after the first ring. The maximum number of rings that can be configured is 255. Setting the value
to zero (0) disables auto-answer completely.
S6
Wait Time for Dial Tone
Unit:
1 second
Range:
Default:
2–255, 4–255**, 4–7***
2, 4**,4***
Description: S6 sets the time the modem waits after the RETURN key is pressed before
executing a dial command. The default setting is two seconds (Decimal 2).
S8
Pause Time for Comma
Unit:
1 second
Range:
Default:
0–255, 4–255**, 4–7***
2, 4**, 4***
Description: S8 sets the length of the pause caused by a comma in a dialing command. The
default setting is two seconds (Decimal 2) or four seconds, where each unit is one second. S8
may be set for up to 255 seconds.
S8 also sets the time the modem waits before retrying a call after detecting a busy signal. Some
computer systems need more than two seconds to reset (in which case you should increase the
value of S8).
125
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
S11
Tone Dialing: Tone Spacing and Duration
Unit:
Range:
Default:
1 ms
1–255, 80–255*, 80–255***
70, 80*, 80***
Description: S11 sets the speed of tone dialing (spacing and tone duration times). The default
value is 70 units (Decimal 7) or 80 units, where each unit is one ms, meaning that each tone is
on for 70 ms with a 70 ms pause between each.
The minimum S11 value allowed by most telephone systems is 50 ms (50 units). Very few
telephone systems can handle anything faster than that. The maximum S11 value is 255 ms (255
units).
S13
Remote Configuration Escape Character
Unit:
Range:
Default:
Decimal number
0–127
37 (%)
Description: S13 defines the remote configuration escape character (which becomes your
modem’s remote configuration character) by its decimal ASCII code. The default is three percent
symbols (%%%). When the S13 character is entered three consecutive times from a remotely
connected site, your modem responds with its remote configuration procedure.
S18
Automatic Leased Line Restoral
Unit:
Range:
Default:
1 minute
10–255
30 minutes
Description: When the MMH2834 is in dial backup mode, it periodically checks the lease line to
see if it is operational and tries to restore the lease line if necessary. S18 defines how frequently
it does this. S18 can be set in one minute increments from 10 to 255 minutes; the default is 30
minutes. Setting S18 under 10 minutes causes excessive breaks in dial-up operation.
S19
Dial-Back Timer
Unit:
Range:
Default:
1 minute
0–255
1
Description: S19 is a timer that begins when the lease line goes down. S19 specifies the
duration of time the modem attempts to reestablish the lease line connection.
126
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
Appendix F - MMH2834 Modem Commands
F.1 Introduction
Before you can enter commands for the MMH2834 internal composite link modem, you must
access the modem using the composite link access enable command (#CLA1). When you have
configured the MMH2834 modem, disable access from the command port to the composite link
using the composite link access disable command (#CLA0). The following sections describe the
MMH2834 modem commands.
MMH2834 Command Summary
TYPE
COMMAND
DESCRIPTION
Dial
D
Dial
(Section F.2)
A: or :
$D
Continuous Redial
DTR Dialing
N
Dial a Stored Number
Modify Dialing
Procedures
(Section F.3)
P/T
&P
,
Y
W
R
Pulse/Tone Dialing
Set Pulse Dial Ratios
Automatic Pauses in dialing
Long Space Disconnect
Wait for New Dial Tone
Reverse Mode of Operation
Flash On Hook
!
$
@
AT&T “Calling Card” Tones
Quiet Answer
Memorize Phone D...N
Store Phone Numbers
Number Linking
List Numbers Stored in Memory
Numbers
NN
L
(Section F.4)
Store Modem
Configurations
and Defaults
(Section F.5)
&F
&W
Z
Load Factory Defaults
Store Configuration & S-Register Parameters
Reset Modem
V
Result Code Terse/Verbose
&M
&X
Synchronous/Asynchronous Mode Select
Synchronous Transmit Clock Select
Configure
Command
Responses
(Section F.6)
Q
&Q
E
Result Codes Enable/Disable Response
Result Code Selection
Echo Command Characters
V
Result Code Terse/Verbose
X
Result Code...Basic/Extended/Call Progress
Condition
Phone Line
(Section F.7)
&T
#T
Remote Digital Loop Signal
Enable/Disable Trellis Coded Modulation
RS232C Interface &D
Data Terminal Ready Control
(Section F.8)
127
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
TYPE
COMMAND
DESCRIPTION
Configure
Error
Correction
(Section F.9)
#L0
#L1
#L2
#L3
$A
Negotiate V42 Mode During Handshake
MNP On/LAPM Off
LAPM On/MNP Off
Direct LAPM/Phase Out Handshake
Auto-Reliable Buffering
$F
$R
Enable/Disable Auto-Reliable Fallback Character
Retransmit Count
$E
Error Correction at 300 bps
Compression &
Block Size
(Section F.10)
&BS
&E14
&E15
Maximum Block Size
Data Compression Disabled
Data Compression Enabled
Configure Speed $BA0
Speed Conversion On
Conversion
(Section F.11)
$BA1
$MB
$SB
Speed Conversion Off
Set modem speed (e.g.,$MB28800)
Set serial port speed (e.g.,$SB115200)
Execute
Immediate
Action
Commands
(Section F.12)
$H
I
L5
L6
L7
L8
Help
Product Code Inquiry
List Current Operating Parameters
List S-Register Values
List Additional Configuration Parameters
List On-line Diagnostics
Read and Assign Sr?
S-Register Values Sr=
(Appendix E)
Read Current S-Register Value
Assign S-Register Value
128
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
F.2 Dialing Action Commands
Dial Command
D
The letter D in a command causes the MMH2834 to dial the telephone number immediately
following it. For example, if you enter ATD5551212 and hit RETURN, the MMH2834 dials the
number 555-1212.
The MMH2834 gives you several choices of dialing methods. You can use tone or pulse dialing,
by inserting a letter T or a P in the command string. (See section F.3 on Dial Modifiers).
You can also configure the modem to either wait for and detect dial tones and busy signals
(which we call “Wait-for-Dial-Tone” dialing or “Smart” dialing), or work with timed pauses without
dial tone and busy signal detection (which we call “Blind” dialing; see section F.6, Result Codes.)
Note: There is another method of dialing, called “DTR Dialing”, where by manipulating the DTR
signal on pin 20 of the RS232C/V.24 interface, a number stored in the modem's memory is
automatically dialed. See section on DTR Dialing ($D command) for details.
Continuous Redial
A: or :
If you select the Wait-For-Dial-Tone method of dialing (see X3 or X4 command), you can
command the MMH2834 to continuously redial (up to 10 redials for DOC units) a busy number
until your call is answered. This is done with the A: command.
This command would be used only if you had already reached a busy number after executing a
normal dial command. You simply enter A: (you need not enter AT, nor do you need to hit
RETURN), and the modem will redial the number for you. If you again reach a busy signal, it
redials again and again until it no longer detects a busy signaF. You can stop the MMH2834 from
redialing by pressing any key.
Another method used to cause the modem to redial a phone number continuously is to enter a
colon : at the end of the phone number. The result is the same as if you had entered A: after
personally observing that the number was busy on the first dialing attempt. Using the colon in the
dialing string is a step saver.
Dialing a Stored Number
N
A telephone number that you have stored in the MMH2834’s number memory may be
automatically dialed by entering ATNn where n = 0, 1, 2, 3, 4, 5, 6, 7, 8 or 9. For example, a
number stored at N3 would be dialed by entering ATN3 and RETURN. Do not include the letter D
in this command, or the stored number will be erased (also see section F.4, Phone Number
Memory Commands).
DTR Dialing
$D
An alternate method of causing the MMH2834 to automatically dial is DTR Dialing. Data Terminal
Ready (DTR) is a signal that comes into the modem from the terminal or computer to whichit is
connected, on pin 20 of the RS232C interface. In DTR dialing, the modem automatically dials a
stored number as soon as it receives a high DTR signal. The DTR dialing method is popular in
synchronous applications.
To activate DTR Dialing, enter AT$D1 and hit RETURN. The modem dials the phone number
stored in the N0 location of memory when it receives a high DTR signal. DTR must remain high
for the duration of the call, until disconnect. To deactivate DTR dialing, enter AT$D0 and hit
RETURN.
129
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
F.3 Dial Modifier Commands
Pulse or Tone Dial
P
T
The MMH2834 dials numbers using either pulse or tone dialing, or a combination of both
methods. Pulse dialing is a method used by rotary-dial telephones, which involves the timed
opening and closing of line relay.
Tone dialing is the method used by pushbutton (touch tone) telephones, and is sometimes
referred to as DTMF, or Dual-Tone Multi-Frequency dialing.
The method used is selected by including a P for Pulse or a T for Tone in the dialing command,
right before the digits you wish to have dialed in that manner.
For example, you would pulse-dial the number 555-1212 by entering ATDP5551212 and hitting
RETURN. You could tone-dial the same number by entering ATDT5551212 and hitting RETURN.
If neither Pulse nor Tone dialing is specified in the dial command, the MMH2834 uses whatever
method used last. If the modem has been reset or just powered up, it uses Pulse dialing, even if
the letter P is not included in your dial command.
Nearly all telephone systems in the U.S. are now compatible with tone dialing. Since that is the
faster method, you will probably choose the tone method for your dialing.
An example of combining pulse and tone dialing could involve a PBX system where 9 had to be
pulse-dialed first, then the rest of the number tone-dialed after pausing for a second dial tone.
The number would be dialed by entering ATDP9, T5551212 and RETURN. (The comma causes
a pause, which we’ll explain soon.)
Set Pulse Dial Ratios &P
This command sets the time ratios between the open and closed portions of the dialing pulse
frequencies. To set the dialing pulse ratio of 60 ms to 40 ms, enter AT&P0. To set a ratio of 67
ms to 33 ms, enter AT&P1. The factory default is &P0.
Automatic Pauses in Dialing
,
You can cause the MMH2834 to pause during the dialing sequence by entering a comma
character where the pause is desired. This pause will last two seconds. If a longer pause is
desired, more than one comma may be entered consecutively, with each comma causing a two
second pause. You also have the option of changing the length of the pause caused by the
comma, from two seconds to any other value from 0 up to 255 seconds. This is done by setting
register S8 (see Appendix E). Each comma in a dialing command counts as one of the sixty
allowed characters.
Long Space Disconnect
Y
When two modems are connected in Normal mode (i.e., without error correction) there is no
"polite" means of requesting a disconnect. A link disconnect request packet is sent under reliable
connections. As a result some "garbage" may be received when a hangup command is issued.
The Y1 command enables the modem to use the break signal which accomplishes the hangup as
an instruction to shut off its receiver and disconnect (both modems must have Y1 enabled for
this feature to be effective). Y0 (factory default) disables this function.
130
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
Wait for New Dialtone
W
A W inserted in the dialing command causes the MMH2834 to wait for another dial tone, and not
resume dialing until another dial tone is detected. It is not necessary to enter a W at the
beginning of the dialing command to wait for a modem dial tone, because the modem will do that
first (pause automatically).
In order for this command to work, you must select Wait-For-Dial Tone dialing with the X2 or X4
command, so that your modem will be able to detect the dial tone.
Reverse the Mode of Operation
R
In certain operations you may need to reverse the mode of operation for your modem from
originate to answer or answer to originate so that it would answer the phone and go into answer
mode. This command turns off the reversing function with the R0 command and turns it on with
the R1 command with the modem in either command mode. If you want to reverse from the
originate mode, use R (with no number) in the dialing string.
Flash On Hook
!
Some switchboard systems react to a momentary On Hook. An exclamation mark inserted in the
command causes the modem “flash” on hook for a half second (90 mSec in BABT), as if you had
held the switch hook button on a telephone down for a half second.
For example, to flash On Hook after dialing the number 555-1234 in order to transfer to extension
5678, you might enter ATDT5551234,,!5678. The commas cause a 4 second pause (just to be
safe).
“Calling Card” Detect Tones
$
The MMH2834 has the capability to detect AT&T "calling card'' tones for the purpose of utilizing
the user's calling card number to originate an on-line connection. A $ symbol placed in the
dialing string causes the modem to pause and wait for an AT&T "calling card" or a 1600 Hz tone
(prevalent in the United Kingdom). When the tone is detected, the rest of the dialing string is
processed. If no tones are detected within 45 seconds the modem aborts by indicating a NO
CARRIER message. Hitting any key also aborts the $ command.
The following is an example of this command:
ATDT1028806127853500$123456789
(access/phone number) (credit card number)
Quiet Answer @
The @ command causes the MMH2834 to wait before processing the next symbol in the dialing
string. The wait is for one or more ringbacks followed by 5 seconds of silence.
If 45 seconds pass before the rings and silence, a NO ANSWER (R) result code is processed.
The @ command is used for accessing a system that does not provide a dial tone.
For example, ATDT5551212@6313550 causes the MMH2834 to dial the first number (555-1212)
and wait for 45 seconds for at least one ringback and 5 seconds of silence. If a busy signal is
detected, the MMH2834 hangs up and generates a BUSY result code. If it does not detect 5
seconds of silence, a NO ANSWER result code is generated after hanging up. If 5 seconds of
silence is detected, the second number (631-3550) is then dialed.
131
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
F.4 Phone Number Memory Commands
Storing Phone Numbers
D...N
A telephone number and command line of up to sixty characters may be stored in the
MMH2834’s number memory. As many as ten of these numbers may be stored. Each number
will be given a name, using the codes N0, N1, N2 up to N9. A phone number is stored by
entering ATD, then the number as it would be dialed, along with any P, T, R, ; or comma
characters, and then entering N followed by the number’s “name,” which would be any number
from 0 through 9, and then hitting RETURN.
For example, the tone-dialed number 1-612-631-3550 would be stored as number N3 by entering
ATDT16126313550N3 and RETURN. The number is not dialed with this store command. After
storing a number, check to see that it has been stored correctly by typing ATL and hitting
RETURN.
When phone numbers are stored, the entire command line is also stored so that you can
effectively create a macro for each number. For example, if you know a particular number needs
to detect busy signals or dial tones, and needs extended result codes, error correction, XON/
XOFF flow control, pacing, and data compression enabled, the command line would be:
ATX4&E1&E5&E13&E15DT16126313550N3. This would store the entire command at location
N3.
Number Linking
N...N
You may command the MMH2834 to dial another number automatically if the first number dialed
is bysy. This would be useful in a situation where a computer can be accessed through more
than one phone number. This is called “linking.” To link the number in N1 to the number N2,
simply enter ATN1N2 and hit RETURN. Several numbers can be linked in the same command.
For example, you could link N1 to N2 to N3 to N4 by entering ATN1N2N3N4 and RETURN or you
could link N1 to N2 and back to N1 and then back to N2 by entering ATN1N2N1N2 and
RETURN.
The only limit on the number of numbers that can be linked is the 60 characters allowed in a
command line. Number linking can not be used with blind dialing, since busy signals would not be
detected. You would have to select the Wait-for-Dial tone dialing method using the X Command in
order to use the Number Linking feature.
Listing Numbers Stored in Memory
L
Telephone numbers that you have stored in the MMH2834's memory may be listed and displayed
with the L command. It will display all ten stored N numbers in a format like that shown below.
All digits and command letters will be shown. The storage location number (0–9) is shown first,
followed by the complete dialing command and telephone number as originally entered.
Simply enter ATL and hit RETURN to display these numbers on your video screen or printer. An
example of an L command listing is shown below:
0
1
2
3
4
5
6
7
8
9
T14082345678
T16125551212;
P9,T14089876543
T3738315,12101,16126313550
T6313551R
P9,4258513
X4&E1&E5&E13&E15DT16126313550
T12138880123
132
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
F.5 Configuration and Default Storage Commands
Store Configuration & S-Register Params. in Non-Volitile Memory &W
The MMH2834 can store configuration parameters and S-register values in its non-volatile read/
write Random Access Memory (RAM) memory. The &W command does this, which prevents any
reconfiguration from being lost on a power-down or Reset (ATZ) condition. &W0 (or AT&W)
causes the MMN2834 to store your customized AT command settings and S-register values in its
nonvolatile RAM. &W0 also sets the modem so that it reads your customized settings stored in
nonvolatile RAM when powered down or reset. (The &W0 command only changes the settings
stored in nonvolatile RAM that you specifically intend to alter. All other default parameters are
applicable.)
&W1 causes the MMH2834 not to store your customized settings to nonvolatile RAM so that,
after powering down or resetting the modem, it reads the factory default settings stored in ROM.
Loading Factory Defaults
&F
The &F command provides a choice between customized con figuration settings in RAM and the
factory default configuration settings in ROM. The &F8 and &F9 commands define the func tion
of the &F command.
The MMH2834 is shipped from the factory with a pre-configured set of command and S-register
default settings. This set of factory defaults can be recalled by issuing the &F command. In
addition to being able to recall the factory-installed defaults, the &F command can also recall
those defaults stored under &W0. This is done using the &F9 command. If you have stored
parameters with the &W0 command and wish these settings to always be used as your defaults,
you would enter &F9&W0.To return the &F command to read factory installed defaults, enter
&F8&W0. &F8 is the factory default.
Many datacomm programs, including MultiExpressTM and MultiExpress for WindowsTM, issue the
&F command automatically—the &F9 command allows the user to select their own defaults. Note
that the &F8/&F9 commands should be used with &W0.
Modem Reset
Z
The Z command can be used to reset the entire command mode buffer and the result is the
same as if you had disconnected, and then reconnected power to the modem. When an ATZ
command is executed, the state of the &W command determines where the default values
originate. &W0 defaults come from RAM and &W1 defaults come from ROM.
Async/Sync Mode Switching
&M
This command can be used to set the on-line mode to either synchronous or asynchronous.
AT&M0 will set the MMN2834 to Asynchronous mode, and all communications will be
Asynchronous, in both On-line and Command modes. AT&M1 causes the MMH2834 to
communicate asynchronously when in Command mode and switch to synchronous mode while
on-line. The modem defaults to &M0 (asynchronous communications) on reset or power-up.
Synchronous Transmit Clock Select
&X
The &X command selects the Synchronous Transmit Clock Source in conjunction with the
MuxClock ($MUXCL) command for the composite link. External clocking is the default condition.
External clocking is when the DTE provides transmit clocking to the modem on pin 24 of the
RS232C interface. &X0 is the default setting which is internal clocking. Internal clocking is when
the modem provides transmit clock to the DTE on pin 15 of the RS232C/V.24 interface. The &X1
command selects External clocking. &X2 enables Slave Clocking. The &X2 Command causes
the MMH2834 to generate the transmit clock timing (pin 15) from the receive clock (pin 17) from
the DTE (therefore 15 and 17 are the same). In this mode (Slave Clocking), all timing is
controlled by the receive clock.
133
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
F.6 Command Response (Result Code) Commands
Echo Command Mode Characters
E
If the MMH2834 is connected to a full-duplex computer, it may be necessary for the modem to be
configured to echo back characters entered while in the command mode in order for them to be
displayed. The E command is used to configure the Command Mode echo, with ATE0 disabling
the echo and ATE1 enabling the echo (default).
Result Codes Enable/Disable and No Response Answer
Q
The Q command enables or disables Result Codes and the No Response Answer mode of
operation. Result Codes may be disabled altogether in certain applications, such as computer-
controlled auto dialing, using the Q command. ATQ1 disables Result Code transmissions. ATQ0
(or ATQ) enables Resul Code transmission.
Regarding No Response Answer, you may want the answer mode handled without responses
and echo turned off, but want the originate mode still intelligent. This is called the No Response
Answer mode. ATQ2 selects the No Response Answer mode. If you do not select any mode, the
factory default setting (enable Result Codes) is automatically selected.
Result Codes (“Multi-Tech” or “Standard AT”)
&Q
The MMH2834 gives you a choice between the Multi-Tech Result Codes and Result Codes that
more closely match the standard AT command set responses. AT&Q1 selects AT responses with
no Reliable/Compression modifiers. With this command, the terse result code for CONNECT
2400 is 10.
TERSE
VERBOSE
0
OK
1
CONNECT
2
RING
3
4
NO CARRIER
ERROR
5
6
7
CONNECT 1200
NO DIAL TONE
BUSY
8
NO ANSWER
CONNECT 2400
CONNECT 4800
CONNECT 9600
CONNECT 14400
CONNECT 19200
CONNECT 21600
CONNECT 24000
CONNECT 26400
CONNECT 28800
10
11
12
13
19
21
24
26
28
AT&Q0 selects Multi-Tech responses with Reliable/Compression modifiers. With this command,
the terse result code for CONNECT 2400 is 9.
134
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
TERSE
0
VERBOSE
OK
1
CONNECT
2
RING
3
4
NO CARRIER
ERROR
5*
6
7
CONNECT 1200
NO DIALTONE
BUSY
8
9*
NO ANSWER
CONNECT 2400
CONNECT 4800
CONNECT 9600
CONNECT 14400
CONNECT 19200
CONNECT 21600
CONNECT 24000
CONNECT 26400
CONNECT 28800
11*
12*
13*
19*
21*
24*
26*
28*
* When error correction is used, the word RELIABLE (verbose) or the letter R (terse) is added to
these responses. When data compression is used, the word COMPRESSED (verbose) or the
letter C (terse) is added to these responses
Result Codes (Verbose/Terse)
V
The V command controls whether the MMH2834's result MMH2834’s result codes are displayed
as word (“verbose”) or single digit (“terse”) messages.
For example, if after dialing, no carrier signal is detected, the resulting message can be
displayed either as NO CARRIER, or as the digit 3.
Entering ATV0 (or ATV) causes the MMH2834 to display the Result Codes as digits, while ATV1
displays them as words. If you do not select a method, the factory default setting causes the
modem to display Result Codes as words.
Result Codes (Basic and Extended) and Call Progress Selection X
The X Command is used to select one of two possible dialing methods ("dumb or "smart"), and to
select various response combinations related to these methods. You can choose to have certain
responses suppressed, or whether or not you want speed indications along with the CONNECT
responses. You can also pick and choose certain responses in order to match up with “Standard
AT” responses.
The MMH2834 provides Basic and Extended Result Code sets. The difference between the two
is the Basic set provides one response (CONNECT) to indicate a connection, while the Extended
set provides several responses for different speeds (CONNECT, CONNECT 2400, CONNECT
4800, CONNECT 9600, CONNECT 14400 CONNECT 19200, CONNECT 21600, etc.).
When the Extended set is chosen, you also have the option of matching them up with Standard
AT 2400 response code sets, by including or not including the BUSY and/or NO DIAL TONE
responses while excluding the DIAL TONE response. The X command is used to select which
responses are provided.
Regarding the MMH2834’s method of dialing, the MMH2834 can detect standard dial tones and
busy signals. This capability (“smart dialing”) allows the modem to wait for a dial tone, and when
one is detected, to begin dialing immediately.
135
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
The MMH2834 also can detect a distant busy signal, if after dialing, it reaches a busy number.
This is useful because it allows the modem to immediately abandon a call, rather than wait 45
seconds for a carrier signal that will never come.
The MMH2834 gives you a choice between the wait-for-dial-tone (“smart”) method we just
described, and blind (“dumb”) dialing, where instead of detecting actual dial tones, the modem
relies on timed pauses. When the wait-for-dial-tone method is chosen, the busy signal detection
capability is also activated. The X command is also used to select which dialing method is used.
Five different X commands are available (X0 through X4), with five different effects on the
MMH2834’s Result Codes.
X0 Provides the basic (short) result codes and provides “dumb” dial capabilities.
X1 Provides the extended result codes and provides “dumb” dial capabilities.
The remaining X commands affect Call Progress, and turn on Extended Result Codes.
X2 Looks for dial tone only and will not provide a busy response.
X3 Looks for busy only and not look for dial tone.
X4 Looks for dial tone and for busy.
The factory default setting is X0, which selects Basic Result Codes and the blind (“dumb”)
method of dialing.
136
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
F.7 Phone Line Conditioning Commands
Enable or Disable Recognition of Remote Digital Loop Signal
&T
The MMH2834 has several self-test features (covered in Appendix G). The tests are activated
with different U commands, such as ATU1, and so fortF. The &T command is a phone line
conditioning command that enables or disables the modem's ability to recognize the Remote
Digital Loop (RDL) test signal. The AT&T4 command lets the MMH2834 respond to a RDL signal,
and places itself in digital loop. The AT&T5 command causes the modem to ignore the RDL
signal. The factory default is &T5.
Enable/Disable Trellis Coded Modulation
#T
This command enables or disables the Trellis Coded Modulation of the MMH2834. There is
usually no need to disable (turn-off) Trellis codings except under an unusual line condition called
impulse noise. AT#T0 turns Trellis coding off and AT#T1 turns Trellis coding on (factory default).
Fallback Modes When On-Line
#F
If line conditions deteriorate, the MMH2834 automatically drops its transmission speed
(“fallback”). The #F command control the different ways the MMN2834 falls back. During
operation, if the error rate becomes too great, the modem performs a retrain. If after the retrain,
the error rate is still too high for 28800 bps operation, the modem initiates a retrain at 4800 bps.If
after the first retrain the modem returns on line at 28800 bps, the modem then starts a counter
and a timer. If three retrains occur within a two minute period, the modem falls back to 4800 bps.
Entering AT#F0 (or AT#F) allows no fallback when on-line. AT#F1 allows the MMH2834 to
fallback (based on the error rate or if three retrains have occurred within a two minute period)
from 28.8K to 26.4K to 24K to 21.6K to 19.2K to 16.8K to 14.4K to 12K to 9.6K to 4.8K bps.
The AT#F2 command enables incremental fall back from 28.8K to 4.8K, but also enables
incremental fall forward (from 4.8K to 28.8K) if the phone line improves. AT#F2 is the factory
default setting.
F.8 RS232C Interface Control Commands
Data Terminal Ready Control
&D
Data Terminal Ready (DTR) on pin 20 of the RS232C interface is required in order for the
MMH2834 to operate. A high DTR signal tells the modem that the device to which it is connected
is active, or "ready" to communicate through the modem.
DTR has some other MMH2834 functions. DTR can be used to trigger a dialing sequence, called
DTR Dialing. The condition of DTR can also be used to cause the modem to reset to its default
parameters, just as if you had given the modem an ATZ command. To do this, enter the
command AT&D3 and hit RETURN. The modem will now reset itself whenever DTR is dropped
from On to Off, and will also go on-hook (hang up) if it is on-line.
Entering AT&D0 or AT&D causes the MMH2834 to ignore DTR. Entering AT&D1 causes the
modem to go on-hook (hang up) with loss of DTR. The modem enters Command mode when
DTR goes high again. Auto-answer is disabled while DTR is low. Entering AT&D2 causes the
modem to go on hook with loss of DTR. The modem enters command mode when DTR goes
high again.
137
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
F.9 Error Correction Commands
You can use AT commands to place your MMH2834 one of three V.42 (error correction) modes of
operation.
V.42 Mode Select
#L
The V.42 standard implements both MNP Class 3 & 4 and LAP-M error correction methods. The
V.42 Mode Select command (#L) selects which type of error correction (MNP or LAP-M) your
MMH2834 uses for transmissions. The various #L command options are as follows.
The #L0 command allows a pair of modems to negotiate which V.42 mode (MNP or LAP-M) will
be used in their transmissions.
Originate Mode
a. If both modems have LAP-M capability, the modems use LAP-M mode.
b. If one or both modems do not have LAP-M capability and both have MNP, the modems use
the MNP mode.
Answer Mode
a. The answering modem responds to either an MNP Link Request or LAP-M Originator
Detection Pattern (ODP) signal depending on which the originating modem issues.
The #L1 command sets your modem to MNP error correction and disables LAP-M. This
command is for Originate mode only. In Answer mode, the modem still accepts MNP or LAP-M.
The #L2 command sets your modem to LAP-M error correction, and disables MNP. This
command is for Originate mode only. Answer mode still accepts MNP or LAP-M.
In the prior commands, the modems use a two phase process to establish a V.42 connection
(detection to establish whether the remote modem is also error correcting, and then protocol
establishment to determine parameters and to establish the error correction connection). If you
know that the other modem is a V.42 error correcting modem, and you wish to use LAP-M, the
#L3 command disables the detection phase and goes directly to protocol establishment. Both
modems must have #L3 in effect.
Auto-Reliable Buffering
$A
In Auto-Reliable mode, the modem is given four seconds to establish a Reliable connection. After
this four-second period, the modem drops to Normal mode.
Any data which is received during this period is typically discarded. The $A command can be
used to cause the modem to buffer (save) data that is received during this Auto-Reliable time-out
period. This data will then be output by the modem after the CONNECT message.
AT$A0 = Discard data received during auto-reliable time period.
AT$A1 = Buffer data received during auto-reliable time period.
The factory default is $A0.
138
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
Enable/Disable Auto-Reliable Fallback Character
$F
In Auto-Reliable mode, the modem is given four seconds to establish a Reliable connection. If a
single CARRIAGE RETURN is received from the remote modem during this four second period,
the Auto-Reliable modem assumes that the remote modem is not in Reliable mode and drops to
Normal mode. The CARRIAGE RETURN is the only character which causes the modem to drop
to Normal mode. Any other character will either be buffered or discarded.
The $F command can be used to disable this fallback-to-Normal-due-to-CARRIAGE-RETURN
feature.
The Auto-Reliable fallback character ($F) and Auto Reliable buffering ($A) commands can be
used together to cause the modem to buffer all data received up until the CARRIAGE RETURN,
and then drop to Normal mode. All data received will then be output following the CONNECT
message.
AT$F0 =
AT$F1 =
Do not fall back to Normal if CARRIAGE RETURN received.
Fall back to Normal mode if CARRIAGE RETURN received.
The factory default is $F0.
Retransmit Count
$R
Retransmit Count If errors are received during a Reliable connection, the modem re-sends the
block of data which contained an error. With the $R0 command, if another error occurs, the block
will be re-sent again. The modem counts the number of times that a data block is re-sent. If the
same block of data is resent 12 times and still has not been received properly, the modem
assumes that the transmission line is unsuitable for transmission, and abort the connection.
This retransmit counter is disabled by the $R1 command. When the retransmit counter is
disabled, the modem keeps trying to send data and will not abort, no matter how many times the
same block is resent.
AT$R0 = Disconnect if retransmit count is exceeded.
AT$R1 = Do not disconnect due to retransmits.
The factory default setting is $R0.
V.42 Error Correction/300bps
$E
At 300 bps, error correction is not typically used. $E1 lets the MMH2834 function at 300 bps in
either Normal (&E0), Auto-Reliable (&E1) or Reliable (&E2) mode. $E0, which is the the
MMH2834’s default, disables 300 bps/V.42 error correction altogether.
139
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
F.10Compression and Maximum Block Size Commands
Data Compression
The data compression (&E14) command enables data compression.
Maximum Block Size
&BS
The maximum size of Reliable mode data blocks can be controlled with the &BS command.
MNP 3 sends blocks of 1 to 64 characters. MNP 4 and 5 typically send blocks of 1 to 256
characters and LAP-M typically sends 128 characters. For MNP classes 4 and 5/LAP-M,
reducing the block size to 64 characters may give a smoother flow of data and better throughput
on noisy phone lines. Using smaller block sizes over good phone lines may cause a slight loss in
throughput (speed).
AT&BS0 = Maximum transmit block size of 64 characters
AT&BS1 = Maximum transmit block size of 128 characters (LAP-M) 256 characters (MNP)
The factory default setting is &BS1.
140
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
F.11 Speed Conversion Commands
Speed conversion is a necessary part of data compression since data must be presented to the
modem faster than it can handle data, if data compression is to be effective.
Speed conversion allows the MMH2834 to communicate at one speed over the phone line, and
at another speed at the RS232C interface. The speed (also referred to as “data rate” or “baud
rate”) can be fixed at the RS232 interface independently of the baud rate of the on-line
transmissions.
In addition to data compression, another popular application for speed conversion involves an
auto-answer MMH2834 connected to a computer that does not have autobaud capability. This
means that the computer must be set at a fixed baud rate, regardless of whether the modem is
communicating over the phone line at 300, 1200, 2400, 9600, 14,400,19,200, 24,000 or 28,800
bps. In this application, speed conversion allows the modem to match its speed to that of the
calling modem, while at the same time communicating with the attached computer through its
RS232C port at a fixed baud rate, which can be preselected at 300, 1200, 2400, 4800, 9600,
19,200, 38,400, 57,600 or 115,200 bps.
Speed Conversion
$BA
When using speed conversion, you must set the modem so that it does not adjust its speed at
the RS232C serial port, even if the modem does adjust its data rate. To turn Speed Conversion
ON, enter the command AT$BA0.
To turn Speed Conversion OFF, enter AT$BA1 and hit RETURN. The modem will now match its
RS232C speed to that of the computer, and will adjust its speed to any changes in the
computer’s speed in Originate mode, or to the speed of the originating modem in Answer mode.
The speed at which the modem communicates over the phone line will always be the same as
the speed at which it communicates via its RS232C serial port.
Modem Baud Rate
$MB
Modem Baud Rate The $MB command presets the MMH2834’s transmission baud rate for
originate operations, (i.e., the speed of the modem's transmissions over the telephone lines when
originating a call). With speed conversion, this transmission speed can be a different baud rate
than the serial port speed.
When the MMH2834 receives (answers) a call from another modem, it automatically switches its
phone line transmission speed to match the calling modem. However, if the MMH2834 originates
a call to another modem that is unable to connect at the baud rate of the MMH2834, it
automatically drops to a lower baud rate in an attempt to match the speed of that modem. For
example, if the MMH2834 is set for 19,200 baud and calls another modem that has a top speed
of 2400 baud, it drops to 2400 baud.
The command to set the Modem Baud Rate is AT$MBn, where n can be 75 (in ITU-TSS V.23
mode) 300, 1200, 2400, 4800, 9600, 14,400,19,200 or 28,800 as listed below:
AT$MB75
AT$MB300
=
=
=
=
=
=
=
=
=
=
CCITT V.23
300 bps
AT$MB1200
AT$MB2400
AT$MB4800
AT$MB9600
AT$MB14400
AT$MB19200
AT$MB24000
AT$MB28800
1200 bps
2400 bps
4800 bps
9600 bps
14400 bps
19200 bps
24000 bps
28800 bps
The factory default is 28800 bps.
141
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Serial Port Baud Rate
$SB
The $SB command presets the speed of the MMH2834's serial (RS232C) port, in both Originate
and Answer modes. Speed conversion allows you to set this serial port baud rate at a fixed
speed of up to 115,200 bps, regardless of the modem’s transmission speed setting.
In order for this command to be effective, the modem’s Speed Conversion feature must first be
turned off with the $BA command. When Baud Adjust is on, the MMH2834 automatically adjusts
its serial port baud rate to match the speed of the computer or terminal it is connected to, as soon
as it receives its first AT command. However, in many applications, such as automatic answer,
the modem may not receive AT commands, in which case it is very useful to be able to preset the
serial port baud rate with this $SB command.
In addition to setting the MMH2834’s serial port speed, this command also sets the speed at
which the modem issues Command mode responses.
The MMH2834 will accept AT commands at any speed, regardless of the speed preset by the
$SB command. If the modem receives such a command at a speed that is different than the
preset speed, the modem switches its serial port baud rate to match the new AT command
speed, although the baud rate value stored by the $SB command remains the same. This
provides you with a convenient way to switch the serial port speed, and still make it easy to go
back to the original speed automatically the next time the modem is powered up or reset with an
ATZ command.
The command to set the Serial Port Baud Rate is AT$SBn, where n can be 300, 1200, 2400,
4800, 9600, 19,200, 38,400, 57,600 or 115200 bps as listed below:
AT$SB300
=
=
=
=
=
=
=
=
=
300 bps
AT$SB1200
AT$SB2400
AT$SB4800
AT$SB9600
AT$SB19200
AT$SB38400
AT$SB57600
AT$SB115200
1200 bps
2400 bps
4800 bps
9600 bps
19,200 bps
38,400 bps
57,600 bps
115,200 bps
The factory default is 115,200 bps.
*Some serial ports, particularly those in older PC-compatible computers, may limit the
performance of a higher speed modem like the MMH2834. The limiting factor is a circuit called a
Universal Asynchronous Receiver/Transmitter, or UART. All data from your modem flows through
it. 8250, 16450, and 16550 are UARTs typically used in PC-compatible computers. The 8250 is
unreliable above 9,600 bps and the 16450 is unreliable above 19,200 bps. The 16550 UART,
however, is reliable to at least 115,200 bps. With V.42bis data compression enabled, the
MMH2834 can achieve throughputs approaching 115.2K (depending on line quality and file
content). If you presently do not have a 16550 UART in your PC, we recommend that it be
replaced with a Multi-Tech high speed Intelligent Serial Interface (ISI) card. It comes in one, two
and eight-port versions for DOS/Windows and UNIX systems, and includes a 32 K buffer that
eliminates data loss even at high speeds. See your dealer for details.
142
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix F - MMH2834 Modem Commands
F.12Immediate Action Commands
Help Screens
$H
The Help command is designed to give you short explanations on how to use each MMH2834
command. The Help command can be quite useful if your manual is not handy and you are in the
middle of a communications session. Although the explanations are quite abbreviated compared
to those in this manual, they should prove to be helpful reminders when needed. At the time of
this writing, we have three screens of Help information (Screen #1, #2 and #3), and more
screens may be added in the future. The Help commands are structured so that you can call up
one of three Help screens, as follows:
AT$H1 = Help Screen #1
AT$H2 = Help Screen #2
AT$H3 = Help Screen #3
Inquiry for Product Code
I
Some systems or software packages automatically check the “identification” of the modem with
which they are communicating, by using the I command. This “read” command lets the software
to determine the type of modem with which it is communicating.
When ATI or ATI0 is entered, the MMH2834 responds with 247. When ATI1 is entered, the
modem responds with a three-digit code indicating the firmware version number. When ATI2 is
entered, the modem responds with MMH2834.
Listing Current Operation Parameters
L5, L7
The L5 and L7 commands list the current operating parameters of your modem. This information
can be very useful when you are changing communications software or when you are changing
modem default settings.
The command to list the MMH2834’s current operating parameters is ATL5 for the basic
parameters. The ATL7 command will list additional parameters on the MMH2834.
Listing S-Register Values
L6
The L6 command lists the current values stored in the modem's S-register. This information can
be very useful if you wish to change S-register values. (Refer to Appendix E for more information
on S-registers).
143
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Listing On-Line Diagnostics
L8
The L8 command displays the current on-line CONNECT status status of the MMH2834. This
display can be printed and used as a modem status report or as diagnostic information (such as
when calling Tech Support).This report is given only when on-line. To activate this command first
type +++AT<CR> (on-line escape command while maintaining command mode), then type ATL8.
What then displays on your monitor is your modem's current on-line condition (e.g., Link Type,
Line Speed, Serial Speed, Type of Error Correction/Data Compression, Number of past
Retrains,etc.).
An example of L8 listing is shown below:
ATL8
******
ONLINE DIAGNOSTICS
******
LINK TYPE
V.34
LINE SPEED
SERIAL SPEED
28800
115200
ERROR CNTRL/COMPRESS
FALL BACK/FORWARD
LINE TYPE
LAPM COMPRESSED
LOCALLY ENABLED
DIAL UP
DATA FORMAT
LINE QUALITY
RECV. SIGNAL LEVEL
TRANS SIGNAL LEVEL
NUMBER OF RETRAINS
ROUND TRIP DELAY
ASYNCHRONOUS
0010=EXCELLENT, 8=FAIR, 16=BAD
-016.5 dBM
-013 dBM
000
00ms (MEANINGFUL IN V32 MODE ONLY)
144
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
Glossary
A
AC (Alternating Current): A power source whose signal crosses a reference voltage (usually called ground or zero). Alternating
between a maximum and minimum voltage, AC may also be referred to as a bipolar signal. Contrast with DC.
ACK (ACKnowledgement code) (pronounced "ack"): A communications code sent from a receiving modem to a transmitting modem
to indicate that it is ready to accept data. It is also used to acknowledge the error-free receipt of transmitted data. Contrast with NAK.
Address: A numbered location inside a computer. It's how the computer accesses its resources, like a video card, serial ports,
memory, etc.
Alphanumeric: The basic character set which includes the letters A to Z (and a to z) and the digits 0 to 9.
Amplitude: The difference between the maximum and minimum voltages of a waveform expressed as a "peak-to-peak" voltage.
Amplifier: An active device within a circuit which increases the voltage level of all signals (desirable and undesirable).
Analog loopback: A modem diagnostic used to test either the local analog loop (the modem's internal circuitry) or the remote analog
loop (the telephone line). The local analog loop test is accomplished by activating the self-test mode and tying the modem's modulator
to its demodulator and examining the return stream of data at the PC or terminal it services. The remote analog loopback can only be
activated on four-wire leased line connections with a remote modem capable of performing the same test.
Analog signal: A waveform which has amplitude, frequency and phase, and which takes on a range of values between its maximum
and minimum points. Analog implies continuous movement from point A to point B, as opposed to discrete jumps. For example, sound
is continuously varying air vibrations and is converted into analogous electrical signals to be carried on a telephone line.
Analog Transmission: One of two types of telecommunications which uses an analog signal as a carrier of voice, data, video, etc. An
analog signal becomes a carrier when it is modulated by altering its phase, amplitude and frequency to correspond with the source
signal. Compare with digital transmission.
ANSI (American National Standards Institute) (pronounced "ansy"): A U.S. standards organization supported by over 1000
companies and trade organizations. It is a non-profit, non-government group that is the U.S. member of the ISO (International Stan-
dards Organization).
ANSI character set: An 8-bit character set that contains 256 characters. The first 128 characters are alphanumeric punctuation and
the second 128 contain math and foreign language symbols.
ASCII (American Standard Code for Information Interchange) (pronounced "askey"): A binary code for data that is used in
communications and in many computers and terminals. The code is used to represent numbers, letters, punctuation and control
characters. The basic ASCII code is a 7-bit character set which defines 128 possible characters. The extended ASCII file provides 255
characters.
Asynchronous Transmission: The transmission of data in which each character is a self-contained unit with its own start and stop
bits. This is a common method of transmission between a computer and a modem. One character at a time, encoded into a series of
electrical pulses, is transmitted or received. This the oldest method of data transfer. When it is used with error correcting software and
data compression algorithms, along with the increase in maximum attainable speeds, it continues to be a viable alternative to synchro-
nous transmission..
Auto Answer: A modem feature which enables the modem to go "off-hook" when it detects an incoming call.
Auto Dial: Some modems provide this feature for asynchronous dialing. This feature is a predefined macro that allows the user to
enter the location of a phone number (i.e., N0 through N9) and have the modem go off hook, dial and establish the connection. With the
auto dial feature, an asynchronous terminal can establish a dialing directory without running a communication software package.
B
Baud: Baud is rate, the signalling rate of a line, the switching speed, or the number of transitions (voltage or frequency changes) that
are made per second. Transmission speeds are often expressed in baud, though bits per second is more accurate. The speed at which
your computer talks to your modem.
BCC (Block Check Character): An error control method used in character-oriented or byte-synchronous protocols. Two 8-bit BCC's
are used to create the CRC (Cyclic Redundancy Check) field of a synchronous data packet.
Bell 103: The U.S. modulation standard for 300 bps full-duplex transmission over dial-up lines.
Bell 212A: The U.S. modulation standard for 1200 bps full-duplex transmission over dial-up lines.
Binary: A numbering system based on two digits, 1 and 0 which is conducive to the two-state digital electronics used within computers.
All input to a computer is encoded as a binary value. Binary also refers to a file format that uses 8-bit characters, to allow for control
characters (i.e., all non-ASCII files).
145
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
BSC (Binary Synchronous Communications): Also called "bisync", this communications protocol was the first synchronous data
format used by IBM. It is still in use, but is rapidly being replaced by IBM's newer Synchronous Data Link Control (SDLC). Bisync is a
byte-synchronous protocol that has longer delays and more overhead than the bit-synchronous SDLC. It uses two synchronization
characters to head every packet.
Bit (Binary digIT): A bit is the basis of the binary number system. It can take the value of 1 or 0. Bits are generally recognized as the
electrical charge generated or stored by a computer that represent some portion of usable information.
Bit-synchronous transmission: A synchronous form of data transmission that focuses on a maximum packet size rather than the
length of the characters the packet contains. SDLC is a bit-synchronous protocol.
Boot: To start or restart your PC. This term originates from the saying " to pull oneself up by the bootstraps".
Bps (bits per second): A unit to measure the speed at which data bits can be transmitted or received. Bps differs from baud when
more than one bit is represented by a single cycle of the carrier.
Buffer: A temporary storage register or Random Access Memory (RAM) used in all aspects of data communications which prevents
data from being lost due to differences in transmission speed. Keyboards, serial ports, muxes and printers are a few examples of the
devices that contain buffers. A buffer allows one device to dump data at a high speed and for the lower-speed device to accept it at its
own pace. In this way , the high-speed device can continue its work without having to wait for its data transfer to end. Buffers are a way
of preventing potential data loss.
Bus: A common channel between hardware devices either internally between components in a computer, or externally between stations
in a communications network.
Byte: The unit of information a computer can handle at one time. The most common understanding is that a byte consists of 8 binary
digits (bits), because that's what computers (PCS) can handle. A byte holds the equivalent of a single character (such as the letter A).
C
Capacitor: An electronic device that stores an electrical charge. It comes in varying sizes for use in anything from power supplies to
the tiny cells in dynamic RAM chips. When the device is powered down, it's capacitors lose their charge.
Carrier signal: An analog signal with known frequency, amplitude and phase characteristics used as a transport facility for useful
information. By knowing the original characteristics, a receiver can interpret any changes as modulations, and thereby recover the
information.
CCITT (Consultative Committee for International Telephone and Telegraph): An advisory committee created and controlled by the
United Nations and headquartered in Geneva whose purpose is to develop and to publish recommendations for worldwide standardiza-
tion of telecommunications devices. Now known as the International Telecommunications Union (ITU-T), CCITT has developed modem
standards that are adapted primarily by PTT (post, telephone and telegraph) organizations that operate telephone networks of countries
outside of the U.S.
Character set: One of a number of coding schemes which uses binary digits to represent characters, numbers, punctuation, and/or
control characters. Common character sets are ASCII, ANSI or EBCDIC.
Checksum: A control field found in synchronous data packets which contain the results of the error control algorithm used.
Chip: Also called integrated circuits (IC), they are squares or rectangles that contain from a few dozen to a few million electronic
components.
Circuit: Any closed path through which electrical current can flow.
Circuit-switched Network: A technology used by the PSTN that allocates a pair of conductors for the exclusive use of one communica-
tion path. Circuit switching allows multiple conversations on one talk path only if the end-users multiplex the signals prior to transmis-
sion.
Circuit switching: The temporary connection of two or more communications channels using a fixed, non-shareable path through the
network. Users have full use of the circuit until the connection is terminated.
Clock: A timing signal generated by an oscillating circuit which is used to synchronize data transmissions.
Command: An instruction that tells a computer to begin, continue or end a specific operation.
Command mode: One of two states of an intelligent (i.e. programmable) device. The mode in which commands can be issued to alter
operating parameters.
CRC (Cyclic Redundancy Check): A field used in packetized data that contains two 8-bit BCCs ( Block Check Characters) as the
binary result of an algorithm performed on the data bits in the packet. A CRC is used for error detection by many synchronous protocols.
CTS (Clear To Send signal): With communications between modems, an RS-232 signal sent from the modem to the DTE that
indicates it is ready to accept data. Contrast with RTS.
D
DC (Direct Current): This is usually understood to mean a constant voltage supply that fluctuates only a nominal amount. An analog or
digital signal that may vary in voltage level, but it never crosses the reference voltage (usually called ground). Contrast with AC.
146
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
De facto standards: A de facto standard is one of two types of voluntary standards recognized by a given market. It is introduced by a
single vendor and becomes a standard by its widespread use and acceptance by other vendors. AT&T's Bell 212A, IBM's Binary
Synchronous Protocol or DEC's VT-100 terminal protocol are examples of de facto standards. Compare with de jure standards.
De jure standards: A de jure standard is one of two types of voluntary standards. It represents the collective consensus of the industry
and users for a particular aspect of manufacturing. ITU-T's V and X standards (e.g. V.32 and X.25) are examples of de jure standards.
Compare with de facto standards.
Decibel (dB): A unit of measurement for signal strength based on logarithmic increments. A decibel is a relative measurement that is
derived from an initial reference level and a final observed level.
Default: This is preset value or option in software packages, or in hardware configuration, that is used unless you specify otherwise.
Device driver: Software that controls how a computer communicates with a device, such as a printer or mouse.
Digital signal: Digital devices, such as terminals and computers, transmit data as a series of electrical pulses which have discrete
jumps rather than gradual changes.
Digital Transmission: A method of electronic information transmission common between computers and other digital devices. Analog
signals are waveforms: a combination of many possible voltages. A computer's digital signal may be only "high" or "low" at any given
time. Therefore, digital signals may be "cleaned up" (noise and distortion removed) and amplified during transmission.
DIP switch (pronounced "dip switch"): A set of tiny toggle switches, built into a DIP (dual in-line package), used for setting
configurable parameters on a PCB (printed circuit board).
DPSK (Differential Phase Shift Keying): A common form of phase modulation used in modems. It does not require complex
demodulation circuitry and is not susceptible to random phase changes in the transmitted waveform, thus reducing errors during
transmission.
DSR (Data Set Ready): An RS232 signal sent from the modem to the computer or terminal indicating that it is able to accept data.
Contrast with DTR.
DTE (Data Terminating Equipment): A term used to include any device in a network which generates, stores or displays user
information. DTE is a telecommunications term which usually refers to PCs, terminals, printers, etc.
DTMF (Dual-Tone MultiFrequency): A generic push-button concept made popular by AT&T TouchTone.
DTR (Data Terminal Ready): An RS232 signal sent from the computer or terminal to the modem indicating that it is able to accept
data.
E
EBCDIC (Extended Binary Coded Decimal Interexchange Code) (pronounced "eb suh dick"): An IBM character code used in its
mainframe and midrange computers. It is an 8-bit code (256 combinations) that stores one alphanumeric character or two decimal digits
within a byte. This code and ASCII are the most commonly used to represent data.
Echo: The reflection or duplication of a signal back toward its source. Echoing is useful when a terminal is transmitting data, in that the
data can be echoed to the screen so the user can monitor what is being sent. Echoing is undesirable when it refers to the signal which
results on a telephone line from impedance mismatches.
Echo cancellation: A high speed modem technique that isolates and filters out unwanted signals caused by echoes from the main
transmitted signal. This allows full-duplex modems to send and receive on the same frequency carrier.
EIA (Electronics Industries Association): A membership organization founded in 1924 that includes manufacturers of electronic parts
and systems. With over 1200 members, it sponsors shows and seminars and gives awards for outstanding contributions in electronics.
It sets electronic interface standards, such as RS-232.
Environment: A computer configuration that includes the CPU model and system software (operating system, data communications
and database systems). It may also include the programming language used. It sets the standards for the applications that run in it.
EPROM (Erasable Programmable Read Only Memory) (pronounced "eeprom"): A reusable PROM chip that holds its contents until
erased under ultraviolet light.
Error correction: The process of detecting distorted data bits and requesting a retransmission or interpretation to correct the error.
Errors are introduced by bad line conditions or external interface.
F
Fax (facsimile): Refers to the bit-mapped rendition of a graphics-oriented document (fax) or to the electronic transmission of the image
over telephone lines (faxing). Fax transmission differs from data transmission in that the former is a bit-mapped approximation of a
graphical document and, therefore, cannot be accurately interpreted according to any character code.
Firmware: A category of memory chips that hold their content without electrical power, they include ROM, PROM, EPROM and
EEPROM technologies. Firmware becomes "hard software" when holding program code.
Flash Memory: A memory chip that holds its content without power, but must be erased in bulk. The term comes from its ability to be
erased "in a flash". Flash memory is derived from EEPROM, but are less expensive and provide higher bit densities.
147
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Flow control: The process of regulating the speed at which data enters or leaves a serial port. Software flow control is implemented by
communications software or by the user sending predefined characters or packets which are recognized as "pause" and "resume"
indicators. Hardware flow control is achieved by using the RTS (request to send) and the CTS (clear to send) control lines of the RS232
interface.
Footprint: The desk or floor surface that a piece of hardware occupies. Also referred to as "real estate".
Foreground: The application program currently running on and in control of the PC screen and keyboard. The area of the screen that
occupies the active window. Compare with background.
Format:
1. The way text is set up on a page.
2. To prepare a disk for holding information. Formatting a disk can delete all information that was previously on it.
3. The way information is structured in a file, often specific to one application or protocol.
Frequency: A characteristic of an electrical or electronic signal which describes the periodic recurrence of cycles. Frequency is
inversely proportional to the wavelength or pulse width of the signal (i.e., long wavelength signals have low frequencies and short
wavelength signals yield high frequencies).
Full-duplex: A method of transmitting and receiving data simultaneously over a single pair of wires. Compare with Half-Duplex.
H
Half-Duplex: The transmission of data in both directions, but only one direction at a time. Compare with Full-Duplex.
Handshaking: A process that two modems go through at the time of call setup to establish synchronization over the data communica-
tions link. It is a synchronization and negotiation process accomplished by the exchange of predefined, mutually recognized control
codes.
Hard Disk: A metal disk covered with magnetic recording material. Some can hold up to several hundred megabytes of information.
Contrast with floppy disk.
Hardware: The equipment that makes up your computer system, including the keyboard, mouse, disk drives and monitor.
Hexadecimal: A base 16 numbering system used to represent binary values. Hex uses the numbers 0-9 and the letters A-F: usually
notated by an "h" (e.g., "4CF h", read "four charley fox, hex"). The result is that one hex digit represents a 4-bit value.
Host: The computer that is designated as retaining information or processing power to service the needs of other computers or
terminals. Mainframes and mid-range computers are hosts; however, with today's powerful microprocessors, PCs can also be config-
ured to serve as hosts. Often, a PC on a LAN will be set up as a host to provide LAN access for remote users.
I
Initialize: To start anew and establish start-up parameters, typically involves clearing all or some part of the device's memory or disk
space.
Interface: A common meeting ground supplied by hardware or software to facilitate a compatible connection and operation between
two devices or programs. For example, when two PCs are connected, they use a common interface across the physical connectors, so
that the signals being sent and received are accurately interpreted. With software, an interface is a module created to be "written to".
That is, if two programs are written to the same interface, then they can be successfully linked together.
International Telecommunications Union (ITU): An advisory committee created and controlled by the United Nations and headquar-
tered in Geneva whose purpose is to develop and to publish recommendations for worldwide standardization of telecommunications
devices. Its standards bureau, ITU-T, was formerly known as the CCITT.
IRQ Level (Interrupt Request Level): The notification a processor receives when another portion of the computer's hardware requires
its attention. IRQs are numbered so that the device issuing the IRQ can be identified, and so IRQs can be prioritized.
ITU-T (International Telecommunications Union - Telecommunications Standardization Sector): The primary international
standards organization for wired public communications networks, formerly known as the CCITT.
K
Kilobit: One thousand bits. A unit of measure for digital data rates.
Kilobyte: One thousand bytes. A unit of measure for digital data rates. Not to be confused with "K", which stands for z10 bytes of
storage space, either in memory or on disk. 1K of disk space is actually 1024 bytes, 16K is 65,536 bytes and 1M (meg) is 1,048,576
bytes.
148
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
L
Leased Line: A private, dedicated communications channel that connects two locations. This connection lasts for the duration of the
subscription. Leased lines may be conditioned to improve line quality over that of dial-up lines.
Line Conditioning: An additional cost option offered by the telephone company for their leased, voice-grade lines. The service
provides a careful balance of line enhancements to improve the frequency response and to reduce distortion.
LRC (Longitudinal Redundancy Check): Error checking method that generates a parity bit from a specified string of bits on a
longitudinal track. In a row and column format such as on magnetic tape, LRC is often used with VRC, which creates a parity bit for
each character.
M
Mainframe: A large, powerful computer used to centralize a data processing environment. It has hundreds of gigabytes of disk storage
space. It uses a front end processor to connect directly to the communications channels that interconnect terminals and computers.
Megabyte: One million bytes when describing a data rate. 1M of disk space may actually mean 1,048,576 bytes.
Mid-range computer: A term coined by IBM referring to any of their Advanced Business Systems computers. This product line was
originally called their mini-computers, but as the number of supported users approached mainframe capabilities, the term "mid-range"
caught on.
Mnemonics: A term assigned to a complex idea, value, or list of information which is found to be representative of that information.
Computer commands are almost entirely mnemonics. Mnemonics are used as memory aids for people.
Modem: A communications device that enables a computer to transmit information over a telephone line. It converts the computer's
digital signals into analog signals to send over a telephone line and converts them back to digital signals at the receiving end. Modems
can be internal and fit into an expansion slot, or external and connect to a serial port.
Modulation: The process of encoding information from one signal (called the source) into another (called the carrier) by modifying
some characteristic(s) of the carrier. It is often used in telecommunications when one type of signal must be converted for transmission
over an otherwise incompatible medium.
Multiplexer (mux): A device that merges several signals into one composite signal for transmission over a single medium or channel.
A de-multiplexer (usually built into a mux) reverses the process at the receiving end.
N
NAK (Negative Acknowledgment): Communications code used to indicate that a message was not properly received, or that a
terminal does not wish to transmit. Contrast with ACK.
Network: A group of computers connected by cables or other means and using software that enables them to share equipment, such
as printers and disk drives to exchange information.
Node: Any point within a network which has been assigned an address.
Normal mode: In modem operation, refers to a mode of operation without error correction active.
O
Off-hook: The condition of a device which has accessed a phone line (with or without using the line). In modem use, this is equivalent
to a telephone handset being picked up. Dialing and transmission are allowed, but incoming calls are not answered.
On-Hook: The condition of a device which has not accessed a phone line. In modem use, this is equivalent to a telephone handset that
has not been picked up. In other words, it can receive an incoming call.
P
Parameter:
1. A "place holder" in a command which should be substituted with useful information.
2. The list of acceptable values for a given option or command. In UNIX, the generic command should be typed in as Stty/s 9600.
Where "Stty" is the command, "s" is the speed switch, and "9600" where s=1200-115,200 bps.
Parity bit: An extra bit attached to each byte of synchronous data used to detect errors in transmission.
PCB (Printed Circuit Board): A flat board that holds chips and other electronic components. The board is "printed" with electrically
conductive pathways between components. The main PCB in a system is called a motherboard and the smaller PCBs that plug into the
slots in the motherboard are called daughter boards or cards.
149
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
PCMCIA (personal computer memory card international association): An organization of U.S. and Japanese companies set up to
standardize memory cards and other architecture-independent expansion devices. These cards are typically used in laptop computers.
Phase: The timing of a signal based upon the starting point of each cycle in another signal. To be detected phase requires the
comparing of two signals. If the cycle of two signals begin at the same point, they are said to be "in-phase". In-phase signals add, while
out-of-phase signals tend to cancel each other.
Port: A location for input or output data exchange. Computers, muxes, etc. have ports for various purposes.
Program: A collection of computer instructions that tell the computer what to do.
PROM (Programmable Read Only Memory): (pronounced "prom") A permanent memory chip that can be programmed or filled by
the customer after by the manufacturer has set initial values. Contrast with ROM.
Prompt: A request for information from the PC that provides required input or information.
Protocol: A set of rules that defines how computing devices communicate with each other. The rules governing the transmitting and
receiving of data.
PSTN (Public Switched Telephone Network): A worldwide public voice telephone network that is used as a telecommunications
medium for the transmission of voice, data and other information.
Pulse dialing: One of two methods of dialing a telephone, usually associated with rotary-dial phones. Compare with tone dialing.
Pulse-width: This pertains to a digital signal. Pulse width refers to the duration of one state between clocking signals. Pulse width
roughly corresponds to an analog signal's wavelength.
Q
Queue: A set of activities that are waiting in chronological order for an action, such as printing, to be performed.
R
Rack: A frame or cabinet into which components are mounted. The industry standard rack is 19" wide and has variable depth and
height.
Rackmount: A packaging style available for many types of electronic equipment which enables the installer to mount the equipment in
an industry standardized enclosure. The rackmount equipment is fitted with brackets, rather than being packaged in its own enclosure.
Rackmounting conserves disk or floor space (real estate) and often conserves power outlets.
RAM (Random Access Memory) (pronounced "ram"): A computer's primary workspace. All data must be stored in RAM (even for a
short while), before software can use the processor to manipulate the data. Before a PC can do anything useful it must move programs
from disk to RAM. When you turn it off, all information in RAM is lost.
RJ-11: An industry standard interface used for connecting a telephone to a modular wall outlet; comes in 4-and 6-wire packages.
RJ-45: An 8-wire modular connector for voice and data circuits.
RJ-48: An 8-wire modular connector for voice and data circuits.
ROM (Read Only Memory) (pronounced "rom"): A memory chip that permanently stores instructions and data. Its contents are
created at the time it is manufactured and cannot be altered. ROM is used to store control routines in PCs and peripheral controllers.
ROM is also used in the plug-in cartridges for printers and video games. A set of ROM chips contain the basic input/output system
(BIOS).
RS232-C: An EIA standard for a serial interface between computers and peripheral devices (modem, mouse, etc.). It uses a 25-pin DB-
25, or a 9-pin DB-9 connector. The RS-232 standard defines the purposes, electrical characteristics and timing of the signals for each of
the 25 lines.
RTS (Request To Send signal): With communications between modems, an RS232 signal sent from the DTE to the modem request-
ing permission to transmit. Contrast with CTS.
S
Serial Port: The connector on a PC used to attach serial devices (those that need to receive data one bit after another), such as a
mouse, a printer or a modem. This consists of a 9- or 25-pin connector that sends data in sequence (bit by bit). Serial ports are referred
to as "COMx" ports, where x is 1 to 4 (i.e., COM1 through COM4). A serial port contains a conversion chip called a "UART" which
translates between internal parallel and external serial formats.
Switched Line: In communications, a physical channel established by dynamically connecting one or more discreet segments. This
connection lasts for the duration of the call after which each segment may be used as part of a different channel. Contrast with leased
line.
Switched Network: A network in which a temporary connection is established from one point via one or more segments.
150
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
Synchronous Transmission: The transmission of data which involves sending a group of characters in a packet. This is a common
method of transmission between computers on a network or between modems. One or more synchronous characters are transmitted to
confirm clocking before each packet of data is transmitted. Compare to Asynchronous Transmission.
T
T1 Transmission: A standard transmission speed of 1.544M bps that may be used in its full bandwidth, or as narrower channels called
"fractional T1" carriers.
Terminal: The screen and keyboard device used in a centralized computing environment for interactive data entry. Terminals have no
"box", which is to say they have no file storage or processing capabilities.
Terminal emulation: This allows a PC to access a mainframe computer by generating and accepting data like a "dumb" terminal.
Threshold: A value or condition which, when reached, triggers an event.
Toggle: To alternate back and forth between two states.
Tone dialing: One of two methods of dialing a telephone, usually associated with Touch-Tone® (push button) phones. Compare with
pulse dialing.
Transistor: A semiconductor device used to amplify a signal, or open and close a circuit. In digital computers, it functions as an
electronic switch.
Twisted pair wiring: A type of cabling with one or more pairs of insulated wires wrapped around each other. An inexpensive wiring
method used for LAN and telephone applications, also called UTP wiring.
U
UART (Universal Asynchronous Receiver/Transmitter) (pronounced "you art"): A chip that transmits and receives data on the
serial port. It converts bytes into serial bits for transmission, and vice versa, and generates and strips the start and stop bits appended
to each character.
UTP (unshielded twisted pair): Telephone-type wiring.
V
V.21: The ITU-T modulation standard for 300 bps, full-duplex transmission over dial-up lines.
V.22: The ITU-T modulation standard for 1200 bps, full-duplex transmission over a dial-up or 2-wire leased line. This is not common in
North America.
V.22bis: The ITU-T modulation standard for 2400 bps, full-duplex transmission over a dial-up or 2-wire leased line.
V.23: The ITU-T modulation standard for 75/1200 bps, half-duplex transmission over dial-up lines. This is not common in North
America.
V.24: The ITU-T hardware interface specification for interchange circuits between the DTE and DCE. Equivalent to the EIA/TIA RS-232
standard.
V.32: The ITU-T modulation standard for 9600 bps, full-duplex transmission over a dial-up or 2-wire leased line.
V.32bis: The ITU-T modulation standard for 14,400 bps, full-duplex transmission over a dial-up or 2-wire leased line.
V.32terbo: The AT&T modulation standard for 19,600 bps, full-duplex transmission over a dial-up or 2-wire leased line.
V.34: The ITU-T modulation standard for 28,800 bps, full-duplex transmission over a dial-up or 2-wire leased line.
V.35: The ITU-T hardware interface specification commonly used by DSU/CSUs and other high-speed devices.
W
WATS (Wide Area Telephone Service) (pronounced "watts"): A discounted long-distance calling plan that allows calls in or out. The
popular 800 numbers are WATS lines in. The calls are charged to the holder of the 800 number at a discounted rate.
Workstation: Traditionally a workstation has been a dumb terminal connected to a host. With the advent of LANs and WANs, PCs that
are connected to a LAN are now called workstations also, even though they are capable of independent processing. A workstation,
then, is simply an input/display device through which a user accesses a resource.
151
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
phone number memory commands...............132
pulse dial (P) .................................................130
pulse dial ratios (&P) .....................................130
response commands.....................................134
result codes, basic/extended (X) ...................135
retransmit count ($R) ....................................139
speed conversion commands .......................141
speed conversion enable ($BA) ....................141
store configuration (&W) ...............................133
tone dial (T) ...................................................130
Composite link ............................................. 10, 12
configuration ............................................ 47, 51
specifications ..................................................16
statistics ................................................. 88, 103
troubleshooting ................................. 62, 91, 92
Composite Link Settings - Internal DSU ...........100
Composite Link Statistics menu..........................78
Configuration ......................................................10
Dial-up link ......................................................21
LAN to LAN .....................................................28
MMH900 series with voice/fax ........................25
PBX to PBX ....................................................32
procedure........................................................48
summary .........................................................45
Configuration Menu ............................................49
Configure TA option ............................................75
Connecting the DataTalker .................................56
Connectors
back panel ......................................................39
Data/Command ................................. 11, 39, 58
Dial-Up ............................................................56
DSU/TA ...........................................................57
E&M ................................................................40
External Composite.................................. 39, 58
frame ground ..................................................39
FXO ......................................................... 11, 39
FXS.......................................................... 11, 39
Leased ..................................................... 40, 57
OPX ................................................................39
PBX station .....................................................59
PBX trunk .......................................................59
telephone ........................................................58
voice/fax channel ............................................ 11
Contents of shipping box ....................................44
Control specifications .........................................16
Index
Symbols
2 or 4 Wire (E&M) option ....................................72
2 or 4 Wire option ...............................................74
A
Answer mode ...................................................138
Answer/Originate option .....................................74
ASCII code ....................................................... 118
Async data channel ............................................16
Async/Sync option ....................................... 67, 69
Auto answer .....................................................125
B
Back panel..........................................................39
Back to Back option ............................................77
Basic result codes ............................................136
Blind dialing ......................................................136
Block diagram.....................................................10
C
Cables
connecting ......................................................56
diagrams .......................................................120
test ..................................................................89
Checkout procedure ...........................................61
Clocking option ..................................... 69, 75, 77
Comma.............................................................125
Command channel .............................................10
switching to .....................................................10
Command Mode Option......................................73
Command port......................................................8
Commands, MMH2834 modem
baud rate, modem ($MB) ..............................141
baud rate, serial port ($SB) ...........................142
calling card tone detect ($) ............................131
compression commands ...............................140
configuration commands ...............................133
continuous redial (A or :) ...............................129
data compression enable ..............................140
dial (D) ..........................................................129
dial modifiers .................................................130
dialing action .................................................129
DTMF dialing.................................................130
DTR control (&D) ..........................................137
DTR dialing ($D) ...........................................129
echo characters (E) ......................................134
error correction commands ...........................138
help screens ($H)..........................................143
immediate action commands ........................143
interface control commands ..........................137
line conditioning commands ..........................137
D
Data channel ............................................... 10, 12
Data port.............................................................10
configuration ................................... 45, 49, 105
Destination Channel option.................................70
Diagnostic testing ...................................... 79, 109
Diagnostics .........................................................13
Dial-back timer .................................................126
Dial-up link configuration ....................................21
Dial/Leased option ..............................................74
152
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Dialtone/Wink (E&M) option................................72
Digital data service (DDS) ..................................10
Digital service unit (DSU) ...................................10
Digitizing Rate option ..........................................70
DIP switch ..........................................................42
DOC ...................................................................15
DSU, internal ......................................................27
configuration ..................................... 47, 51, 52
settings .................................................... 75, 99
specifications ..................................................17
troubleshooting ........................................ 91, 92
Leased line restoral parameter .........................126
LED indicators ............................................. 36, 61
Load number ......................................................15
Loading Factory Defaults (&F) ..........................133
Local Interface Type option.................................72
Loop test.............................................................79
M
Main Menu................................................... 49, 66
Memory ..............................................................12
Memory Test option ............................................79
Menus ................................................................28
56K DSU Configuration ...................................75
Composite Link Configuration .........................73
Composite Link Statistics ................................78
Configurations ................................... 29, 33, 66
Data Port Configuration.............. 29, 33, 67, 69
Diagnostic Tests ..............................................79
DSU ................................................................31
External Device...............................................77
Internal MMH2834 ..........................................73
Internal TA................................................ 34, 75
Loop Tests ......................................................80
Reset Options .................................................79
Voice/Fax Channel ................................... 30, 33
Voice/Fax Channel 1 Configuration .................70
MMH2834 Modem Configuration Menu ..............73
MMV8/16/32 .......................................................42
Model numbers....................................... 8, 14, 20
Modem, internal
E
E&M to E&M configuration .................................20
Echo option ........................................................68
EIA Pass Through option ....................................68
Electrical specifications ......................................18
Enq/Ack Flow Control option ..............................67
Extended result codes ......................................136
External device
configuration ..................................... 47, 51, 53
settings .................................................. 77, 102
F
Fallback ............................................................137
Fax .....................................................................28
FCC regulations..................................................14
Features .............................................................12
Flow control ........................................ 12, 36, 124
hardware .........................................................67
XON/XOFF .............................................. 67, 68
Flow Control option.............................................67
Flush Time option ...............................................75
Frame compatibility switch..................................42
Front panel .........................................................36
FXS to FXO configuration...................................20
FXS to FXS configuration ...................................20
configuration ..................................... 47, 51, 52
settings .........................................................101
specifications ..................................................17
MultiMux MMH904C ...........................................25
O
Output Level Attentuation option .........................70
Overview ............................................................10
G
P
Ground/Loop Start (FXS) option .........................72
Pacing option......................................................68
Parameter memory.............................................12
Parity option .......................................................67
Pass Xon option .................................................68
Pause time .......................................................125
PBX ............................................................. 11, 46
E&M trunk .......................................................32
PBX to PBX configuration...................................32
Power switch ......................................................41
Product and Firmware ID option .........................79
I
Input Level Gain option .......................................71
Intelligent Serial Interface (ISI)..........................142
Internal DSU Troubleshooting.............................94
Internet ............................................................. 115
ISDN...................................................................10
ISDN terminal adapter
configuration ..................................... 47, 51, 52
settings .........................................................100
specifications ..................................................17
R
L
RackTalker rack .................................... 20, 39, 48
Recording DataTalker information..................... 113
Remote configuration escape character ...........126
LAN router ..........................................................10
LAN to LAN configuration ...................................28
153
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTalker Owner’s Manual
Remote Interface Type option .............................72
REN....................................................................14
Ringer equivalence number ................................14
Rings until modem answers..............................125
RS232C/V.24
interface ..........................................................42
specification .................................................. 119
RS232C/V.35 shunt ............................................42
V
V.35
interface ................................................... 42, 58
interface adapter cable....................................58
shunt procedure ..............................................60
Voice ..................................................................28
Voice/fax channel ........................... 10, 11, 12, 17
configuration ................................... 46, 50, 107
default settings ................................................71
troubleshooting ...............................................63
valid configurations .........................................20
S
S-registers ........................................................125
S0 .................................................................125
S11................................................................126
S13 ...............................................................126
S18 ...............................................................126
S19 ...............................................................126
S6 .................................................................125
S8 .................................................................125
Serial ports .......................................................142
Service ............................................................. 113
Shunt, RS232/V.35 .............................................42
Silence Suppression option ................................71
Smart dialing ....................................................135
Specifications .....................................................16
Speed option ................................. 67, 69, 73, 75
Statistics, composite link ....................................13
Stop Bits option ..................................................67
Switches
W
Wait time for dial tone .......................................125
Warranty ........................................................... 112
Watchdog test.....................................................79
Wink Timer (E&M) option....................................72
Word Length option ............................................67
101-MDM/TA...................................................41
DIP.................................................... 42, 56, 79
frame compatibility ..........................................42
Originate .........................................................41
power ..............................................................41
Reset ..............................................................41
Sync data channel ..............................................16
Synchronous Communications ............................8
T
Technical support.............................................. 113
Test cables .........................................................89
Tests .............................................61, 79, 80, 109
back to back....................................................89
internal DSU ...................................................89
internal modem ...............................................89
Tone dialing ......................................................126
Transmit Level option .........................................74
Troubleshooting ......................................... 88, 109
internal DSU ............................................ 91, 92
Troubleshooting Guide .......................................90
U
UART ...............................................................142
Unpacking ..........................................................44
154
Download from Www.Somanuals.com. All Manuals Search And Download.
|