Haier HSU 12C03K User Manual

Installation Manual of Room Air Conditioner  
Read this manual before installation  
Explain sufficiently the operating means to the user  
according to this manual.  
Necessary Tools for Installation  
1.Driver  
5.Torque wrench(17mm,22mm,26mm)  
9.Nipper  
12.Reamer  
2.Hacksaw  
3.Hole core drill  
4.Spanner(17,19 and 26mm)  
6.Pipe cutter  
7.Flaring tool  
8.Knife  
10.Gas leakage detector or  
soap-and-water solution  
11.Measuring tape  
Drawing for the installation of indoor and outdoor units  
Accessory parts  
Number  
of  
No. Accessory parts  
articles  
Remote controller  
1
1
2
1
Optional parts for piping  
Mark  
Parts name  
2
R-03 dry battery  
A
Non-adhesive tape  
Adhesive tape  
B
C
D
3
Saddle(L.S) with screws  
Mounting plate  
Connecting electric cable  
for indoor and outdoor  
Attention must be paid to  
the rising up of drain hose  
Drain hose  
1
6
E
F
4
Drain hose  
Heating insulating material  
Piping hole cover  
A
4X50  
Steel nail, cement  
G
5
4
1
6
7
4X25  
Screw  
Plastic cap  
Cover  
C
Arrangement of piping directions  
Rear left  
Cushion  
4
8
9
Rear  
right  
Left  
1
1
Pipe supporting plate  
Drain-elbow  
Right  
Below  
10  
D
E
G
A
The marks from to in the figure are the parts numbers.  
The distance between the indoor unit and the floor should be  
more than 2m.  
No.0010531057  
Indoor unit  
Connecting the indoor/outdoor Electric Cable  
Removing the wiring cover  
Remove terminal cover at right bottom corner of indoor unit, then  
take off wiring cover by removing its screws.  
When connecting the cable after installing the indoor unit  
1. Insert from outside the room cable into left side of the wall hole, in which  
the pipe has already existed.  
2. Pull out the cable on the front side, and connect the cable making a loop.  
When connecting the cable before installing the indoor unit  
Insert the cable from the back side of the unit, then pull it out on the front side.  
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.  
Pull the cable slightly to make sure the cables have been properly inserted and tightened.  
After the cable connection, never fail to fasten the connected cable with the wiring cover.  
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wi  
is not correct, proper operation can not be carried out and will cause defect.  
ring  
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar  
qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).  
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.  
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.  
3. The wiring method should be in line with the local wiring standard.  
4. After installation, the power plug should be easily reached.  
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the  
distance between its two contacts should be not less than 3mm.  
HSU-09H03/K(F)  
HSU-12H03/K(F)  
HSU-12C03/K(F)  
3
Outdoor unit  
Outdoor unit  
1.Connection of pipes  
To bend a pipe, give the roundness as large as possible not to crush the pipe  
Connecting the pipe of gas side first makes working easier.  
The max vertical distance between the indoor unit and the outdoor unit is 5 m.  
Half union  
Flare nut  
Forced fastening without careful centering  
may damage the threads and cause a  
leakage of gas.  
Fastening torque  
Pipe Diameter  
(
)
Spanner  
18N.m  
40N.m  
55N.m  
Liquid side 6.35mm(1/4")  
Gas side 9.52mm(3/8")  
Gas side 12.7mm(1/2")  
Torque wrench  
Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.  
2.Attaching Drain-Elbow  
If the drain-elbow is used, please attach it as  
figure. (Note: Only for heat pump unit.)  
3.Purging Method:  
Push the air out of the indoor unit and piping as followes:  
Tighten the caps on the valves with specified torque.  
Tighten torque N.m  
7-9  
Valve rod  
Valve cap  
20-25  
When connecting pipe exceeds 5 meters, 20g refrigerant shall be added per  
exceeding meter. Charge according to the following list.  
for 09k 12k  
Piping length  
5m  
7m  
10m  
100g  
Additional amount  
40g  
No need  
Outdoor unit  
Indoor unit  
A
A
A
Outdoor unit  
Oil trap  
B
C
Outdoor unit  
B
Indoor unit  
Indoor unit  
B
Max.Elevation:B=5m  
CAUTION  
C
In case more than 5 metresoil trap  
should be installed every 5~7m.  
Max. Length: for 9k A=7m  
for 12k A=10m  
4

Acumen INSTRUMENTS CORPORATION DATABRIDGETM SDR2 USB User Manual
Briggs Stratton 60100 User Manual
Canon PIXMA MP210 User Manual
Dakota Digital FFW 447 User Manual
Fluke BP130 User Manual
GE ASQ10 User Manual
Haier HSU 09LEK13 User Manual
Heat Controller Inc Air Conditioner VMC30SB 1 User Manual
HP Hewlett Packard Hewlett Packard Hp Laserjet Pro 400 M475dw CE864ABGJ User Manual
HP Hewlett Packard J3600 User Manual