Cautions  
7. The appliance is not intended for use  
by young children or infirm persons  
without supervision.  
Do not obstruct or cover the ventilation  
grille of the air conditoner.Do not put fingers  
or any other things into the inlet/outlet and  
swing louver.  
8.Young children should be supervised  
to ensure that they do not play with  
the applience.  
Do not allow children to play with the air  
conditioner.In no case should children be  
allowed to sit on the outdoor unit.  
9.Please employ the proper power plug,  
which fit into the power supply cord.  
Specifications  
10 .The power plug and connecting cable  
must have acquired the local attestation.  
The refrigerating circuit is leak-proof.  
11.In order to protect the units,please turn  
off the A/C first, and at least 30 seconds  
later, cutting off the power.  
The machine is adaptive in following  
situation  
1.Applicable ambient temperature range:  
32oC/23oC  
Maximum:D.B/W.B  
Indoor  
Minimum:D.B/W.B 18oC/14oC  
Cooling  
Heating  
43oC/26oC  
18oC  
Maximum:D.B/W.B  
Minimum:D.B  
Outdoor  
Indoor  
Maximum:D.B  
Minimum:D.B  
27oC  
15oC  
24oC/18oC  
-15oC  
Maximum:D.B/W.B  
Minimum:D.B/W.B  
Outdoor  
2. If the power supply cord is damaged, it  
must be replaced by the manufacturer  
or its service agent or a similar qualified  
person.  
3. If the fuse of indoor unit on PC board is  
broken,please change it with the type of  
T. 3.15A/ 250V. If the fuse of outdoor  
unit is broken,change it with the type of  
T.25A/250V  
4. The wiring method should be in line with  
the local wiring standard.  
5. After installation, the power plug should  
be easily reached.  
6. The waste battery should be disposed  
properly.  
10  
Cautions  
Safety Instruction  
Please read the following Safety Instructions carefully prior to use.  
The instructions are classified into two levels, WARNING and CAUTION according to  
the seriousness of possible risks and damages as follows. Compliance to the  
instructions are strictly required for safety use.  
Installation  
WARNING  
Please call Sales/Service Shop for the Installation.  
Do not attempt to install the air conditioner by yourself because improper works  
may cause electric shock, fire, water leakage.  
lnstallation in a inadequate place may cause accidents. Do not install in the following place.  
CAUTION  
Do not install in the  
place where there is  
any possibility of  
inflammable gas  
leakage around the  
unit.  
Do not get the unit  
exposed to vapor  
or oil steam.  
Connect the earth  
cable.  
Check proper  
installation of the  
drainage securely  
earthing  
STRICT  
ENFORCEMENT  
PROHIBITION  
PROHIBITION  
11  
Cautions  
Safety Instruction  
Please read the following Safety Instructions carefully prior to use.  
The instructions are classified into two levels, WARNING and CAUTION according to  
the seriousness of possible risks and damages as follows. Compliance to the  
instructions are strictly required for safety use.  
Installation  
WARNING  
Please call Sales/Service Shop for the Installation.  
Do not attempt to install the air conditioner by yourself because improper works  
may cause electric shock, fire, water leakage.  
lnstallation in a inadequate place may cause accidents. Do not install in the following place.  
CAUTION  
Do not install in the  
place where there is  
any possibility of  
inflammable gas  
leakage around the  
unit.  
Do not get the unit  
exposed to vapor  
or oil steam.  
Connect the earth  
cable.  
Check proper  
installation of the  
drainage securely  
earthing  
STRICT  
ENFORCEMENT  
PROHIBITION  
PROHIBITION  
12  
Parts and Functions  
Indoor unit  
OPERATE COOL DRY HEAT TIMER HEALTH  
Display board  
RED  
GREEN  
GREEN  
GREEN  
YELLOW  
RED  
The conversion of pilot light's colors will be displayed as  
the figure under different operation models  
Display board  
Inlet  
Air filter  
(inside)  
Anion generator  
(inside)  
Inlet grille  
Vertical flap  
(Use remote controller to  
adjust up and down air flow.  
Don't adjust it manually)  
Horizontal louver  
(adjust left and right air flow)  
For multi-split type, the power plug is on the outdoor unit  
Outdoor unit  
OUTLET  
INLET  
CONNECTING PIPING AND ELECTRICAL WIRING  
DRAIN HOSE  
1
2
3
4
13  
Parts and Functions  
19  
9. HEALTH button  
Used to set healthy operation.  
10. ON/OFF button  
Used for unit start and stop.  
11. TIMER ON display  
12. FAN SPEED display  
LOW  
HI  
MED  
AUTO  
13. LOCK display  
14. SWING UP/DOWN display  
28  
FRESH  
15. SLEEP display  
16. HEALTH display  
POWER/SOFT  
17.FRESH AIR display  
18. Operation mode display  
Operation mode  
33  
AUTO COOL DRY  
HEAT FAN  
Remote controller  
19.Singal sending display  
20. POWER/SOFT display  
21. Left/right air flow display  
22. TEMP display  
Remote controller: to display the TEMP. setting.  
1.CODE  
23. TIMER OFF display  
24. CLOCK display  
Used to select CODE A or B with a press,A or B  
will be displayed on LCD.  
Please select A without special explanation.  
25. TEMP button  
Used to select your desired temperature.  
2.RESET  
26. FAN button  
When the remote controller appears abnormal,  
use a sharp pointed article to press this button  
to reset the remote controller normal.  
Used to select fan speed: LOW,MED, HI, AUTO.  
27. HEALTH AIRFLOW button  
Used to set the health airflow mode.  
3.LIGHT button  
Control the lightening and extinguishing of  
the indoor LCD display board.  
28. SWING UP/DOWN button  
Used to select up or down air sending direction.  
29. SWING LEFT/RIGHT button  
Used to select left/right air flow.  
4. TIMER button  
Used to select TIMER ON, TIMER OFF,  
TIMER ON-OFF.  
30. FRESH button  
Use to set fresh air function.  
5. CLOCK button  
31. SET button  
Used to set correct time.  
Used to confirm timer and clock settings.  
6. SLEEP button  
Used to select sleep mode.  
7. MODE button  
32. POWER/SOFT button  
33. LOCK  
Used to lock buttons and LCD display. If pressed, the  
other buttons will be disabled and the lock condition  
display appears. Press it once again, lock will be  
canceled and lock condition display disappears.  
AUTO COOL  
DRY  
FAN  
HEAT  
8. HOUR button  
Used to set clock and timer setting.  
3
17  
30  
and  
NOTE:(1) The following functions and related displays are not available:  
(2) Cooling only unit do not have functions and displays related with heating.  
14  
Parts and Functions  
Clock Set  
When unit is started for the first time and after replacing batteries in  
remote controller, clock should be adjusted as follows:  
FRESH  
1. Press CLOCK button,"AM" or "PM" flashes.  
POWER/SOFT  
2. Press or  
to set correct time. Each press will increase or decrease  
1 min. If the button is kept depressed, time will change quickly.  
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing,  
while clock starts working.  
Remote controller's operation  
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.  
The distance between the signal transmission head and the receiver hole should be within  
7m without any obstacle as well.  
Don't throw or knock the remoter controller.  
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or  
wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving  
the signals, so the distance to the indoor unit should be shorter.  
Loading of the battery  
Load the batteries as illustrated right  
2 R-03 (7#) batteries  
Remove the battery cover:  
Slightly press" "area and push down the cover  
as illustrated.  
Load the battery:  
Be sure that the loading is in line with the "+" / "-".  
request as illustrated on the bottom of the case.  
Put on the cover again.  
Confirmation indicator:  
After pressing power ON/OFF, if no display, reload the batteries.  
Note:  
Full display or unclear display during operation indicates the batteries have been used up.  
Please change batteries.  
Used two new same-typed batteries when loading.  
If the remote controller can't run normally during operation, please remove the batteries and  
reload several minutes later.  
Hint:  
Remove the batteries in case unit won't be in usage for a long period. If there are any display  
after taking-out, just need to press reset key.  
15  
Operation  
HEALTH operation  
Remote controller  
1.Unit start  
Press ON/OFF on the remote controller, unit starts.  
2.Health anion function  
Press HEALTH button. For each press,  
is displayed.  
Air conditioner starts health anion function operation.  
For twice press,  
disappears,the operation stops.  
When indoor fan motor is running, it has healthy  
process function. (It's available under any mode)  
FRESH  
When the fan in the indoor unit does not work, the health lamp  
lights up, but the anion generator does not release anion.  
POWER/SOFT  
BRIEF INTRODUCTION TO HEALTH ANION FUCTION  
The anion generator in the air conditioner can generate a lot of  
anion effectively balance the quantity of position and anion in the  
air and also to kill bacteria and speed up the dust sediment in  
the room and finally clean the air in the room.  
16  
Operation  
Auto Operation  
1. Unit start  
Remote controller  
Press ON/OFF on the remote controller, unit starts.  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then  
Select Auto operation  
3.Select temp.setting  
Press TEMP. button  
Every time the button is pressed, temp.setting  
increase 1 C,if kept depressed, it will increase  
rapidly  
FRESH  
POWER/SOFT  
Every time the button is pressed, temp.setting  
decrease 1 C,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed fan speed.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
5.Unit stop  
Press ON/OFF button, the unit stops.  
About Auto Operation  
Under the mode of auto operation, air conditioner will  
automatically select Cool or Heat operation according  
to room temperature.  
17  
Operation  
Cool Operation  
1. Unit start  
Remote controller  
Press ON/OFF on the remote controller, unit starts.  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select COOL operation  
3.Select temp.setting  
Press TEMP. button  
FRESH  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
POWER/SOFT  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed fan speed.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
5.Unit stop  
Press ON/OFF button, the unit stops.  
18  
Operation  
Dry Operation  
Remote controller  
1. Unit start  
Press ON/OFF on the remote controller, unit starts.  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select DRY operation  
3.Select temp.setting  
Press TEMP. button  
FRESH  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
POWER/SOFT  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed fan speed.  
In DRY mode, when room temperature becomes  
lower than temp.setting+2oC,unit will run intermittently  
at LOW speed regardless of FAN setting.  
COOL operation starts when room  
temp.is higher than temp.setting.  
Ultra-low air flow  
Temp.setting+2oC  
Temp.setting  
5.Unit stop  
Press ON/OFF button, the unit stops.  
On reaching temp.setting +2oC  
unit will run in mild DRY mode.  
19  
Operation  
Fan Operation  
1. Unit start  
Remote controller  
Press ON/OFF on the remote controller, unit starts.  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select FAN operation  
3.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
FRESH  
Remote controller:  
LOW  
POWER/SOFT  
MED  
HI  
4.Unit stop  
Press ON/OFF button, the unit stops.  
About FAN operation  
In FAN operation mode, the unit will not operate in  
COOL or HEAT mode but only in FAN mode ,AUTO is  
not available in FAN mode.And temp.setting is disabled.  
In FAN mode,SLEEP operation is not available.  
20  
Operation  
Heat Operation  
1. Unit start  
Remote controller  
Press ON/OFF on the remote controller, unit starts.  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select HEAT operation  
3.Select temp.setting  
Press TEMP. button  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
FRESH  
POWER/SOFT  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed fan speed  
IN HEAT mode, warm air will blow out after a short period  
of the time due to cold-draft prevention function.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
5.Unit stop  
Press ON/OFF button, the unit stops.  
21  
Operation  
Air Flow Direction Adjustment  
1.Status display of air sending  
Vertical flap  
Horizontal louvers  
Pos.1  
Pos.1  
Pos.2  
Pos.3  
Pos.4  
Pos.5  
Pos.2  
Pos.3  
FRESH  
Pos.4  
POWER/SOFT  
Pos.5  
Pos.6  
Pos.7  
Pos.6  
(Auto swing)  
Pos.8  
2.Up and down air flow direction  
For each press of  
button, air flow direction on remote controller displays  
as follows according to different operation modes:  
COOL/DRY/FAN  
remote controller:  
:
Pos.1  
Pos.2  
Pos.3  
Pos.4  
Pos.6  
HEAT:  
remote controller:  
Pos.5  
Pos.1  
Pos.4  
Pos.3  
Pos.3  
Pos.2  
Pos.1  
Pos.6  
Pos.6  
AUTO:  
Pos.2  
Pos.4  
Pos.5  
remote controller:  
The vertical flap will swing according to the above positions  
3.Left and right air flow direction  
For each press of  
remote controller:  
button, remote controller displays as follows :  
Pos.1  
Pos.2  
Pos.3  
Pos.4  
Pos.5  
Pos.6  
Pos.7  
Pos.8  
The horizontal louvers will swing according to the above positions.  
Note:When restart after remote turning off, the remote controller will automatically  
memorize the previous set swing position.  
22  
Operation  
Sleep Operation  
Before going to bed, you can simply press the  
SLEEP button and unit will operate in SLEEP  
mode and bring you a sound sleep.  
SLEEP operation starts  
SLEEP operation stops  
Approx.6hrs  
Use of SLEEP function  
After the unit starts, set the operation status,  
then press SLEEP button before which the  
clock must be adjusted and time being set.  
Operation Mode  
Rises 1O  
C
C
1 hr  
Rises 1O  
1 hr  
1. In COOL,DRY mode  
1 hours after SLEEP mode starts, temp. will  
become 1OC higher than temp. setting. After  
another 1 hours, temp. rises by 1OC further.  
The unit will run for further 6 hours then stops.  
Temp. is higher than temp. setting so that room  
temperature won't be too Iow for your sleep.  
Unit stop  
Temp.setting  
In COOL, DRY mode  
In HEAT mode  
2.  
1 hours after SLEEP mode starts, temp  
will become 2 OC lower than temp.  
setting. After another 1 hours, temp  
decrease by 2 OC further. After more  
Remote Controller  
another 3 hours, temp. rises by 1O  
C
further. The unit will run for further 3  
hours then stops. Temp. is lower than  
temp. setting so that room temperature  
won't be too high for your sleep.  
Temp.setting  
1 hr  
Unit stop  
Decreases 2O  
C
1 hr  
Decreases 2O  
3 hrs  
C
3 hrs  
Rises 1O  
C
SLEEP  
operation stops  
SLEEP  
operation starts  
In HEAT mode  
FRESH  
In AUTO mode  
3.  
The unit operates in corresponding sleep  
mode adapted to the automatically selected  
operation mode.  
POWER/SOFT  
4. In FAN mode  
It has no SLEEP function.  
5.Set the wind speed change when sleeping  
If the wind speed is high or middle before  
setting for the sleep, set for lowing the wind  
speed after sleeping.  
If it is low wind, no change.  
23  
Operation  
Timer On/Off Operation  
Set clock correctly before starting TIMER operation.  
1. After unit starts, select your desired operation mode  
Operation mode will be displayed on LCD.  
2. Timer mode selection  
Remote Controller  
Press TIMER button to change TIMER mode. Every  
time the button is pressed, display changes as follows:  
Remote controller:  
BLANK  
TIMER ON TIMER OFF  
TIMER ON-OFF  
Then select your desired TIMER mode (TIMER ON or  
TIMER OFF). "  
"or "  
"will flash.  
3.Time setting  
Press HOUR  
button.  
Every time the button is pressed, time setting  
increases 1 min, if kept depressed, it will increase  
rapidly.  
FRESH  
ER/SO
Every time the button is pressed, time setting  
decreases 1 min, if kept depressed, it will decrease  
rapidly.  
It can be adjusted within 24 hours.  
4.Confirming your setting  
After setting correct time, press SET button to confirm  
"
"or"  
"on the remote controller stops flashing.  
Time displayed: Unit starts or stops at x hour x min.  
(TIMER ON or TIMER OFF).  
5.Cancel TIMER mode  
Just press TIMER button several times until TIMER  
mode disappears.  
Hints:  
After replacing batteries or a power failure happens, time setting should be reset.  
Remote controller possesses memory function, when use TIMER mode next time,  
just press SET button after mode selecting if time setting is the same as previous one.  
24  
Operation  
Timer On-Off Operation  
Set clock correctly before starting TIMER operation.  
Remote Controller  
1. After unit starts, select your desired operation mode  
Operation mode will be displayed on LCD.  
2. Timer mode selection  
Press TIMER button to change TIMER mode. Every time  
the button is pressed, display changes as follows:  
Remote controller:  
BLANK  
TIMER ON TIMER OFF  
TIMER ON-OFF  
Then select your desired TIMER mode (TIMER ON - OFF).  
"will flash.  
"
3.Time setting  
Press HOUR  
button.  
Every time the button is pressed, time setting increases  
1 min, if kept depressed, it will increase rapidly.  
Every time the button is pressed, time setting decreases  
1 min, if kept depressed, it will decrease rapidly.  
It can be adjusted within 24 hours.  
FRESH  
WER/S
4.Timer confirming for TIMER ON  
After setting correct time, press TIMER button to confirm  
"
"
" on the remote controller stops flashing.  
" starts flashing.  
Time displayed: Unit starts or stops at x hour x min.  
5.Time setting for TIMER OFF  
Just press HOUR button ,follow the same procedure in  
"Time setting for TIMER ON"  
6.Time confirming for TIMER OFF  
After time setting,press SET button to confirm.  
"
" on the remote controller stops blinking.  
Time displayed:Unit stops at x hour x min.  
To cancel TIMER mode  
Just press TIMER button several times until TIMER  
de disappears.  
According to the Time setting sequence of TIMER ON  
or TIMER OFF, either Start-Stop or Stop-Start can be  
achieved.  
25  
Operation  
POWER/SOFT Operation  
POWER Operation  
When you need rapid heating or cooling, you can use this function.  
Selecting of POWER operation  
Press POWER/SOFT button. Every time the button is pressed,display  
changes as follows:  
BLANK  
SOFT  
POWER  
Stop the display at  
In POWER operation status:  
In HEAT or COOL mode, fan speed automatically runs in HI mode  
for 15 min then returns to original status setting.  
To cancel POWER operation  
Press POWER/SOFT button twice ,POWER/SOFT disappears.  
FRESH  
SOFT Operation  
You can use this function when silence is needed for rest or reading.  
Selecting of SOFT operation  
Press POWER/SOFT button. Every time the button is pressed,display  
changes as follows:  
BLANK  
SOFT  
POWER  
Stop the display at  
In SOFT operation mode, fan speed automatically takes"LOW"  
To cancel SOFT operation  
Press POWER/SOFT button twice ,POWER/SOFT disappears.  
Hints:  
During POWER operation, in rapid HEAT or COOL mode, the room  
will show inhomogeneous temperature distribution.  
Long period SOFT operation will cause effect of not too cool  
or not too warm.  
26  
Operation  
Health airflow Operation  
1.Press ON/OFF to starting  
Remote controller  
The liquid crystal will display the working state of last time  
(Except timer, sleeping, power/soft and health airflow).  
Setting the comfort work conditions.  
2.The setting of health airflow function  
1).Press the button of health airflow,  
appears on the  
display. The nether inlet and outlet grills of the air condit-  
ioner are closed and the airflow is blown horizontally from  
the above inlet and outlet grills. Avoid the strong airflow  
blows direct to the body.  
2).Press the button of health airflow again,  
appears on  
the display. The above inlet and outlet grills of the air cond-  
itioner are closed and the airflow is blown vertically from the  
nether inlet and outlet grills. Avoid the strong airflow blows  
direct to the body.  
FRESH  
POWER/SOFT  
3.The cancel of the health airflow function  
Press the button of health airflow again, both the inlet and  
outlet grills of the air conditioner are opened, and the unit  
goes on working under the condition before the setting of  
health airflow function.  
After stopping, the outlet grille will close automatically.  
Notice: Cannot pull direct the outlet grille by hand. Otherwise,  
the grille will run incorrectly. If the grille is not run correctly,  
stop for a minute and then start, adjusting by remote controller.  
Note:  
1 .After setting the health airflow function, the position of inlet  
and outlet grills is fixed.  
2.In heating, it is better to select the  
3.In cooling, it is better to select the  
mode.  
mode.  
4.In cooling and dry, using the air conditioner for a long time  
under the high air humidity, a phenomenon falling drips of  
water occurs at the outlet grille .  
5.Select the appropriate fan direction according to the actual  
conditions.  
27  
Operation  
Emergency and Test Operation  
Emergency operation:  
Use this operation only when the remote controller  
is defective or lost.  
When the emergency operation switch is  
pressed,the" Pi "sound is heard once, which means  
the start of this operation.  
In this operation, the system automatically selects  
the operation modes, cooling or heating, according  
to the room temperature.  
Timer  
mode  
Operation Designated  
Temperature  
Air flow  
mode  
temperature  
ABOVE 21OC  
BELOW 21OC  
AUTOMATIC  
AUTOMATIC  
24OC  
NO  
NO  
COOLING  
HEATING  
24OC  
It is not possible to operate in dry mode.  
Test operation:  
Test operation switch is the same as emergency switch.  
Use this switch in the test operation when the room  
temperature is below 16OC, do not use it in the normal  
operation.  
Continue to press the test operation switch for more  
than 5 seconds. After you hear the "Pi" sound twice,  
release your finger from the switch: the cooling operation  
starts with the air flow speed "Hi".  
After 30 minutes, test operation ends automatically.  
Removal of the restriction of emergency or test operation  
Press the emergency operation switch once more, or manipulate through the  
remote controller; the "Pi" sound, the emergency or test operation is terminated.  
When the remote controller is manipulated, it gets the system back to the  
normal operation mode.  
28  
Maintenance  
For Smart Use of The Air Conditioner  
Setting of proper room  
temperature  
Do not block the air inlet  
or outlet  
Proper  
temperature  
Close doors and windows Use the timer effectively  
during operation  
During cooling operation  
prevent the penetration of  
direct sunlight with  
curtain or blind  
If the unit is not to be used Use the louvers effectively  
for a long time, turn off the  
power supply main switch.  
OFF  
29  
Maintenance  
For Smart Use of The Air Conditioner  
WARNING  
Before maintenance,be sure to turn off the system and the circuit breaker.  
Remote Controller  
Indoor Body  
Wipe the air conditioner by using a soft and  
dry cloth.For serious stains,use a neutral  
detergent diluted with water.Wring the water  
out of the cloth before wiping.then wipe off  
the detergent completely.  
Do not use water, wipe the controller with a  
dry cloth.Do not use glass cleaner or chemical  
cloth.  
Do not use the following for cleaning  
Hot water over 40OC(104OF) may cause  
discoloring or deformation.  
Gasoline,benzine, thinner or cleanser may  
damage the coating of the unit.  
Air Filter cleaning  
Open the inlet grille by pulling it upward.  
Remove the filter.  
Push up the filter's center tab slightly until it is released  
from the stopper, and remove the filter downward.  
Clean the filter.  
Use a vacuum cleaner to remove dust, or wash the filter with  
water.After washing, dry the filter completely in the shade.  
Attach the filter.  
Attach the filter correctly so that the "FRONT" indication is  
facing to the front.Make sure that the filter is completely  
fixed behind the stopper.If the right and left filters are not  
attached correctly, that may cause defects.  
Once every  
two weeks  
Close the inlet grille.  
30  
Maintenance  
Replancement of Air Purifying Filter  
1.Open the lnlet Grille  
Open the inlet grille by pushing each ends of  
the inlet grille upward.(use thumbs to push  
up)  
2.Detach the standard air filter  
Slide the knob slightly upward to release the  
filter, then withdraw it.  
3.Attach old Air Purifying Filter  
Put air purifying filter appliances into the  
right and left filter frames.  
Detach old Air Purifying Filter  
4.Attach the standard air filter  
The green aspect of the bacteria-killing medium  
air purifying filter will face outside, the white  
aspect will face to the machine.  
(Necessary installation)  
5.Close the Inlet Grille  
Close the Grille surely  
NOTE:  
The air purifying filter of the bacteria-killing medium and the electrostatic air  
purifying filter accessories with machine will be used based on real situation.  
The bacteria-killing medium air purifying filter is available for a long time and  
needn't to be changed. But it must be noticed to use the vacuum cleaner frequently  
to adsorb the dusts covering the purifying filter lest the covering dusts effect the  
function of the bacteria-killing medium air purifying filter. (It is strictly prohibited for  
the bacteria-killing medium air purifying filter to be washed)  
The green aspect of the bacteria-killing medium air purifying filter will face outside,  
the white aspect will face to the machine. and the white side of the electrostatic air  
purifying filter will face outside.  
31  
Maintenance  
To Keep Your Air conditioner in Good Condition  
after Season.  
Operate in cooling mode for 2-3 hours.  
To prevent breeding mold or bad smell, be sure to  
operate at the designated temperature or 30OC,cooling  
mode and High speed fan mode for 2-3 hours.  
Put off the power supply cord.  
Cleaning the body.  
Take out the batteries from the  
wireless remote controller.  
32  
Maintenance  
Before Setting in High season  
Cleaning the standard air filter.  
Operation without filter may cause troubles.Be sure  
to attach both right and left filters prior to the operation.  
Each of them are of different shapes.  
Connecting the earthing cable.  
Caution  
Incomplete earthing may cause an electric shock.  
EARTHING  
Do not block the air inlet or outlet.  
Plug-in  
Caution  
After brush away dust at the plug, insert the  
plug of the power supply cord into the outlet  
completely.In case of suing exclusive circuit  
breaker,switch on the circuit breaker.  
NO WET HAND  
33  

Bryant LEGACY 574D User Manual
Carrier 48TJF008 012 User Manual
Continental Electric CE11125 User Manual
Friedrich Air Conditioner CP05C10 User Manual
Friedrich CP18F30 User Manual
Friedrich EQ08N11 User Manual
GE 2 9866 User Manual
Graco MetroLite 1761213 User Manual
Havis Shields Telescoping Computer Base C TCB 12 User Manual
Honeywell Barcode Reader 1900 EZ User Manual