		 SPLIT AIR CONDITIONER   
					OPERATION   
					MANUAL   
					AS102AMARA   
					AU102ACARA   
					(HSU-10HA03(DB))   
					AS102ALARA   
					AU102ACARA   
					(HSU-10H03(DB))   
					AS122AYARA   
					AU122ACARA   
					(HSU-12HA03(DB))   
					AS122AVARA   
					AU122ACARA   
					(HSU-12H03(DB))   
					Digital DC Variable Frequency   
					Healthy Split Air Conditioner   
					Please read this manual carefully before use.   
					Please keep this manual carefully and safely.   
					No.0010540438   
					I 
				Cautions   
					All these valuable materials may be taken to   
					a waste collecting center and used again   
					after adequate recycling.   
					Disposal of the old air conditioner   
					Before disposing an old air conditioner that   
					goes out of use. please make sure it's   
					inoperative and safe. Unplug the air   
					conditioner in order to avoid the risk of child   
					entrapment.   
					Consult your local authorities for the name   
					and address of the waste materials   
					collecting centers and waste paper diposal   
					services nearest to your house.   
					Safety Instructions and Warnings   
					It must be noticed that air conditioner system   
					Before starting the air conditioner,read the   
					information given in the User's Guide   
					carefully. The user's Guide contains very   
					important observations relating to the   
					assembly, operation and maintenance of   
					the air conditioner.   
					contains   
					refrigerants, which   
					require   
					specialized waste disposal. The valuable   
					materials contained in a air conditioner can   
					be recycled. Contact your local waste   
					disposal center for proper disposal of an old   
					air conditioner and contact your local   
					authority or your dealer if you have any   
					question. Please ensure that the pipework of   
					your air conditioner does not get damaged   
					prior to being picked up by the relevant   
					waste disposal center, and contribute to   
					environmental awareness by insisting on an   
					appropriate, anti-pollution method of   
					disposal.   
					The manufacturer does not accept   
					responsibility for any damages that may   
					airse due to non-observation of the   
					following instruction.   
					Damaged air conditioners are not to be   
					put into operation.In case of doubt,consult   
					your supplier.   
					Disposal of the packaging of your   
					new air conditioner   
					Use of the air conditioner is to be carried   
					out in strict compliance with the relavtive   
					instructions set forth in the User's Guide.   
					All the packaging materials employed in the   
					package of your new conditioner may be   
					disposed without any danger to the   
					environment.   
					Installation shall be done by professional   
					people,don't install unit by yourself.   
					The cardboard box may be broken or cut into   
					smaller pieces and given to a waste paper   
					diposal service. The wrapping bag made of   
					polyethylene and the polyethylene foam   
					pads contain no fluorochloric hydrocarbon.   
					1 
				Installation Check and Trial Operation   
					Cautions   
					Please operate the air conditioner in accordance with this Operation Manual   
					Check items for the Trial Operation(Tick   
					Is the connector leaked?   
					in   
					) 
					For the purpose of safety, the air   
					Specifications   
					conditioner must be properly grounded in   
					accordance with specifications.   
					How is the connector insulated?   
					The refrigerating circuit is leak-proof.   
					Is the electric connection between the indoor and outdoor units firmly inserted into the   
					terminal plate?   
					The machine is adaptive in following situation   
					1.Applicable ambient temperature range:   
					Are the electric wires on the indoor and outdoor units fixed firmly?   
					Is the drain pipe placed correctly?   
					Maximum: D.B/W.B   
					Minimum: D.B/W.B   
					32 /23   
					18 /14   
					Always remember to unplug air   
					conditioner before opening inlet grill. Never   
					unplug your air conditioner by pulling on the   
					power cord.Always grip plug firmly and pull   
					straight out from the outlet.   
					Indoor   
					Is the earth line connected firmly?   
					Cooling   
					Heating   
					Does the power supply voltage conform to the electric regulations?   
					Is there any noise?   
					Maximum: D.B   
					Minimum: D.B   
					43   
					15   
					Outdoor   
					Maximum: D.B   
					Minimum: D.B   
					27   
					20   
					Is the cooling operation normal?   
					Indoor   
					Is the indoor temperature adjuster working normally?   
					Maximum: D.B/W.B   
					24 /18   
					Minimum: D.B/W.B -7 /-8   
					Outdoor   
					Power Supply:   
					L should be connected with the live wire;   
					N should be connected with the zero wire;   
					should be connected with the earth wire.   
					All electrical repairs must be carried out   
					by qualified electricians. Inadequate repairs   
					may result in a major source of danger for   
					the user of the air conditioner.   
					2.If the supply cord is damaged, it must be replaced   
					by the manufacturer or its service agent or a similar   
					qualified person. The type of connecting wire is   
					H05RN-F or H07RN-F:3G1.5mm2 +1X0.75mm2..   
					3.If the fuse on PC board is broken please change it   
					with the type of T.3.15A/250V. If the fuse of outdoor   
					uit is broken please change it with the type   
					of T.25A.AC250V.   
					Do not damage any parts of the air   
					conditioner that carry refrigerant by piercing   
					or perforating the air conditioner's tubes with   
					sharp or pointed items, crushing or twisting   
					any tubes, or scraping the coatings off the   
					surfaces. If the refrigerant spurts out and   
					gets into eyes, it may result in serious eye   
					injuries.   
					4.The distance between the indoor unit and the floor   
					should be more than 2m.   
					5.The wiring method should be in line with the local   
					wiring standard.   
					6.After installation ,the power plug should be easily   
					reached.   
					7.The waste battery should be disposed properly.   
					8.The appliance is not intended for use by young   
					children or infirm persons without supervision.   
					9.Young children should be supervised to ensure   
					that they do not play with the appliance.   
					10. The requirement of power supply cord.   
					Do not obstruct or cover the ventilation   
					grille of the air conditioner.Do not put fingers   
					or any other things into the inlet/outlet and   
					swing louver.   
					Series   
					10   
					12   
					Do not allow children to play with the air   
					conditioner. In no case should children be   
					allowed to sit on the outdoor unit.   
					European   
					region   
					H05VV-F   
					3G 1.5mm2   
					H05VV-F   
					3G 1.5mm2   
					2 
					31   
				Installation   
					Name of Parts   
					Indoor Unit:   
					Wiring for Indoor and Outdoor Units   
					1. Inlet Grill   
					1. Wiring Method for Ring Terminal   
					2. Anion Generator (inside)   
					The wiring method is as the drawing below for the ring terminal:   
					Remove the connection screw and put the screw through the ring on   
					the connection wire terminal, then connect it to the terminal blocks,   
					then screw it tightly.   
					3. Air Filter   
					4. Swing louver   
					It can be adjusted to upward or downward with the remote controller only (Do not adjust it manually)   
					5. Power or Healthy Operation Indicator   
					Wiring Method for   
					Ring Terminal Block   
					After the air conditioner is started, this indicator lights up; when the healthy operation is started,this   
					indicator turns green.   
					2.Wiring Method for Line Terminal   
					The wiring method is as follows for the non-ring terminal:   
					Loosen the connection screw and insert the connection wire end into the   
					terminal block completely, screw it tightly, then slightly pull out the   
					connection wire to ensure it be clamped tightly.   
					6. Timer Set Indicator   
					When the air conditioner is at the state of time-set, this indicator lights up.   
					7. Test Manual Button   
					This button is only used for test refrigerating operation when the room temperature is below 16 , so it   
					should not be used in normal situation.   
					8. Emergency Manual Button   
					3. Method for Pressing the Connection Wire   
					When the remote controller is lost or cannot be used, this button can make the air conditioner continue   
					to operate for the time being.   
					After wiring, the connection wire must be pressed tightly with a wire-   
					pressing clip, which should press the outer sleeves of the wire as the   
					9. Remote Signal Receiving Window   
					right drawing:   
					Correct Pressing   
					Wrong Pressing   
					It receives the remote signal from the remote controller.   
					10. Working Method Indicator   
					Terminal   
					block   
					When the compressor is working, the indicator lights up .   
					11   
					11. Power Plug   
					Pressing   
					Clamps   
					1 
					7 
					Wiring for Indoor Unit and Outdoor Unit   
					Lay out the connection wires as the connection drawing (Notes: The two ends of the connection   
					wires are different, never connect reversely)   
					Outdoor Unit:   
					1. Inlet   
					2. Outlet   
					Send out hot air when cooling,   
					and send out cold air when heating .   
					3. Inlet   
					8 
					1) Open the wire cover, unscrew the pressing clamp(outdoor unit).   
					3 
					2) Connect the connection wires as per the wiring method and the wiring drawing (the wires on   
					the indoor unit shall be inserted from behind as the attached drawing).   
					3) Ensure that the terminals are clamped tightly, and press the connection wires(outdoor unit) as   
					per the pressing method, then install the wire-pressing cover.   
					2 
					4 
					5 
					10   
					9 
					6 
					4. Connection pipe and electric wiring.   
					5. Drain Hose   
					Air Inlet Grille   
					3 
					Terminals   
					Pressing Clamp   
					Pressing Cover   
					Screw   
					1 
					Power Supply Wire   
					Indoor and Outdoor   
					Connection Wires   
					4 
					Notes:   
					When connecting the wires of indoor and outdoor units, check the numbers on the terminals   
					of the indoor and outdoor units,the same wire shall connect the same number and color   
					terminal   
					, 
					2 
					Wrong connection would damage the air conditioner s controller,or the unit cannot work.   
					5 
					30   
					3 
				Installation   
					Name of Parts   
					Remote Controller:   
					Piping Connection for Outdoor Unit   
					Introduction to Display and Function:   
					Connect the Piping and Inlet and Outlet Liquid Tubes   
					1. Mode   
					Gas Drainage Method:   
					Mode selected is displayed   
					Drain the air in the indoor unit and the pipes as per the drawing:   
					2. Air Volume   
					(1) Remove the valve cap on the two-way valve of the indoor unit with a spanner.   
					(2) Unscrew by 1/2 cycle the nut on the mouth of the thick pipe connected with the three-way valve   
					with a spanner.   
					(3) Unscrew the spool of the two-way valve by 90owith an inner hexagon spanner, and after about 10   
					seconds,close the two-way valve,then air will be drained out from the mouth of the thick pipe. When   
					the air is drained out, screw tightly the nut on the mouth according to there quired torque.   
					(4) Open the two-way valve and three-way valve with an inner hexagon spanner.   
					(5) Check the leakage with soap liquid or a leakage checker.   
					Indicating the air speed, when automatic is set, the air speed changes according to the temperature   
					difference between the indoor temperature and set temperature.   
					3. Healthy Operation   
					Indicating healthy operation   
					4. Timing Mode Display   
					Indicating time set mode:   
					Normal for non-time-set;   
					Timed off for timed turning off;   
					Timed on for timed turning on;   
					5. Indicating the Time set   
					Indicating the time set on and off   
					6. Mode Selection   
					9 
					(6) Screw tightly the two valve caps according to the required torque.   
					1 
					2 
					Liquid Side   
					6.35mm(1/4")   
					10   
					AUTO   
					ion   
					C 
					Two-way Valve   
					Selecting the modes below:   
					cooling, dehumidifying, and heating   
					7. Timer   
					ON OFF   
					H 
					3 
					4 
					9.52mm(3/8")   
					Gas Side   
					12.7mm(1/2")   
					TEMP   
					11   
					18   
					Mouth Nut   
					Three-way Valve   
					Used to select TIMER ON, TIMER OFF   
					8. Time Set   
					90   
					ON/OFF   
					Open   
					To set the time on and off   
					MODE   
					TIMER   
					SWING   
					FAN   
					Required Torque   
					9. Signal Sending Head   
					5 
					6 
					7 
					To send signal into the signal receiver on the indoor unit   
					10. Signal Display   
					12   
					Torque   
					Tight screw N. M   
					Specif.   
					POWER   
					HEALTH   
					It blinks when the signal is being sent   
					11. Temperature Display   
					RESET   
					Valve Spool   
					Valve Cap   
					7-9   
					20-25   
					14   
					To display the temperature set   
					12. Temperature Set   
					When the connection pipe is more than 5 cm, it shall be filled with refrigerant as per the following   
					form:   
					13   
					15   
					To set the desired room temperature   
					13. On/Off Button   
					19   
					17   
					Pipe Length   
					5m   
					7m   
					10m   
					80g   
					15m   
					Refrigerant filled none   
					32g   
					160g   
					To turn on and turn off the air conditioner   
					14. Air Volume   
					8 
					16   
					Notes: When the pipe is extended, the air in the connection pipe shall be drained out with the   
					refrigerant(R22) from outside the system, then the excess refrigerant shall be drained out as per the air   
					drainage method.   
					To select the desired air speed   
					15. Air flow Direction   
					To adjust the air flow direction   
					16. Healthy Button   
					Check the Layout of the Drain Pipe and Connection Wires   
					The drain pipe should be placed underneath, and the connection   
					wires should be placed upside; and the drain pipe especially the   
					section inside the machine and indoors must be wound up with   
					insulating material to preserve heat   
					To set the healthy operation   
					17. Power Button   
					To set super or soft operation   
					18. Indication for Power Operation   
					19. Reset   
					The drain pipe shall be sloped and no concave and convex shall   
					occur along the whole pipe. And the cases as the right drawing   
					indicates shall not occur.   
					When the remote controller appears abnormal,   
					use a sharp pointed item to press this button to   
					reset the remote controller to normal condition.   
					Notes: After replacing the batteries in the remote controller, press on/off button, the mode is resumed   
					as below:   
					Mode: Refrigerating; Temperature:26   
					Timer: Normal; Fan Speed: Automatic   
					Prohibited   
					Up-bent   
					Prohibited   
					Prohibited   
					Prohibited   
					Bad Smell in the Pool   
					Correct   
					End in the Water   
					Ripple   
					4 
					29   
				Installation   
					Operation Hints   
					Air Conditioner Operation:   
					When the ambient humidity is too high,   
					the anion effect would be reduced, so during   
					the cooling and dehumidifying, water   
					would drop from the outlet mouth   
					4.Piping Connection for Indoor Unit:   
					Insert the auxiliary hoses(liquid hose and gas hose)and the unit connection wires through the wall   
					hole from outdoor side,and connect the pipes and wires as per the method of piping connection, or   
					insert the auxiliary hoses(liquid hose and gas hose) and the connection wires as a whole through   
					the wall hole from indoor side for connecting the outdoor unit after connection of the auxiliary   
					hoses and unit connection wires.   
					3 Minutes Protection:   
					5.Install and Fix:   
					When the air conditioner is turned on immediately   
					after being turned off, the compressor will not start   
					until 3 minutes later to protect the machine.   
					Hang the indoor wall unit on the fastener of the mounting plate,   
					and move the unit left and right to check the firmness.   
					Hold the two sides of the unit with two hands to press the unit   
					to the mounting plate until a sound kacha is heard.   
					Piping Protective Cover   
					Air Speed Change:   
					Installation of Outdoor Unit   
					At the state of cooling, when air is set to automatic   
					, 
					1.Install and Fix:   
					the air speed would decrease automatically when the room   
					temperature is close to the set temperature. In heating   
					mode, when the room temperature is the set temperature,   
					compressor will stop and fan will be low speed or stop;   
					In dehumidifying mode, air speed will change automatically.   
					Fix the outdoor support on the wall with M10 expansion screws, then screw tightly the outdoor   
					unit on the support with M10 bolts and nuts, and leveled. If it is installed on wall or roof, the stand   
					shall be firmly fixed to resist the earthquake or strong wind. A vibration reduction rubber ring   
					shall be used.   
					Air Direction Adjustment   
					105   
					105   
					500   
					At the state of cooling or dehumidifying,   
					it would be better not to let the outlet guide plate   
					be downward for long, otherwise the outlet mouth   
					would be dew.   
					2.Install the Drain Elbow   
					The elbow is only used for the thermal pump type air conditioner.And the cold air type air   
					conditioner does not need it.The elbow shall be installed as per the drawing.The drain elbow is not   
					used in a very cold weather(the air temperature is below 0 for long).   
					Healthy Operation   
					Only when the air conditioner is at the state of operation   
					(normal state), can the healthy operation be started.   
					When the button Health is pressed, the healthy operation   
					will be indicated.   
					Healthy Operation   
					Indication   
					Healthy Button   
					Drain Hose   
					Drain Elbow   
					28   
					5 
				Operation Hints   
					Installation   
					Installation of Indoor Unit   
					Wait a moment   
					Hanging Wire   
					Drop Wire Here   
					Mounting Plate   
					The indoor unit shall be installed as per the indoor unit   
					installation drawing:   
					Cold Air Prevention   
					When heating is started, the fan in the indoor unit will   
					not be started immediately to prevent cold air being blew   
					out.   
					3 
					Wire   
					Dropping Weight   
					Holes for Fixing   
					A145mm   
					Find out the Level Position   
					Defrost   
					A=185mm   
					During the heating, when the heat exchanger in the   
					outdoor unit is frosted, the air conditioner will defrost   
					automatically for a few minutes. During the defrost, the   
					fan in the outdoor unit does not run until the defrost is   
					completed.   
					60mm   
					1.Fix the Mounting Plate and Localize the Wall-through Hole   
					Fix the mounting plate as per the selected position and the piping layout (see the installation   
					drawing).   
					Fix the mounting plate on a smooth wall surface under the beam or beside a column. First fix the   
					mounting plate with a steel nail,then level it with a level meter or a drop line, then fix it with A4   
					50 cement nails.If the expansion screws are used,first drill holes into the wall( 4.8mm), then   
					put the plastic sleeve into the holes,then fix the mounting plate with 4 25 screws. Measure the   
					position the wall hole with a measuring tape.   
					Notes   
					When heating, the air conditioner takes a lot of heat   
					from outdoor and release the heat into the room , therefore   
					the outdoor temperature will affect the heating effect.   
					2.Drill a Hole through the Wall and Install the Piping Protective Sleeve   
					Drill a hole 60mm through the wall with the outer side slightly downward,then install the   
					piping sleeve,then seal it with gypsum powder.   
					Inter side   
					Wall hole   
					60mm   
					Outer side   
					Instructions Operation   
					Thickness of wall   
					Adjust the air flow direction   
					Avoid the direct sunlight and hot air flow   
					3.Piping Layout for Indoor Unit   
					(Section plan of wall hole)   
					Lay out the connection pipe,drain pipe, and the connection wires according to the installation   
					position of the indoor and outdoor units. During the layout, the drain pipe shall be placed   
					underneath,and the connection wires shall be placed on the top; the drain pipe(especially indoor   
					or inside the unit)shall be wound up with the insulating material.   
					Pipe   
					Insulating Material   
					Set a proper room temperature   
					Use of Timer   
					Pipe Clamp   
					Drain Pipe   
					Right Connection   
					Low Connection   
					Too cold and too hot are not only harmful for Time set can make your room in a comfortable   
					health but also will consume too much electricity. temperature when you wake up or come back.   
					Left Connection   
					Electrical Connection   
					between Indoor and   
					Outdoor Units   
					Tape   
					Installation of the Connection Pipe Clips(Left or Left-Back Connection):   
					Insert the pipe clip into the fixing position of the pipe with the upper part inserted first.   
					Press the bottom of the clip until a sound Ka Ta is heard.   
					Best   
					temperature   
					Notes: After installation, please confirm that the refrigerant is not leaked.   
					6 
					Pipe Clamp   
					27   
				Installation   
					Localize the Installation:   
					Operation   
					, 
					Remote Controller s Operation   
					Indoor Unit   
					When in use, point the signal sending head directly to the receiver window on the indoor unit.   
					The distance between the signal sending head and the receiver window should be within 7 m   
					without any obstacle as well.   
					Install the indoor unit where the weight of the unit can be supported.   
					Install the indoor unit where the head source and steam source are not close and the unit inlet and   
					outlet are not blocked.   
					Don't throw the controller, prevent it from being damaged.   
					Install the indoor unit where the drainage is easy and the outdoor unit can easily connected.   
					Install the indoor unit where its cold air and hot air can be easily sent to all the corners of the room.   
					Install the indoor unit where the power socket is near and there is sufficient space around the indoor   
					unit.   
					When electronic-started type fluorescent lamp or change-over type fluorescent lamp or   
					wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the   
					signals so the distance to the indoor unit should be shorter.   
					Install the indoor unit where there is no T.V set, radio set, and wireless appliance underneath, and the   
					sunlight lamp is over one meter away.   
					If the remote controller is installed on the wall, the indoor unit shall be ensured to receive the signal   
					while the sunlight lamp is on.   
					Outdoor Unit   
					The location shall bear the weight of the unit and will not produce a big vibration and noise.   
					The location shall be in good ventilation,and the airflow blew out and noise produced shall not affect   
					the neighbors.   
					The location shall not be directly drenched in rain,sun,or blew by sea wind.   
					The location shall not be near anywhere the corrosive gas(SO2),flammable gas(thinner or gasoline),oil   
					mist,or steam are probably produced(for example in kitchen).   
					Sufficient space shall be left for air inlet and outlet.   
					The location shall be easily maintained and repaired.   
					It cannot be installed on a non-professional metal structure(like anti-burglary net).   
					Method for Cutting and Expanding Pipes:   
					When the pipe is too long or its mouth is damaged,the pipe needs to cut or expand.   
					Expansion Size   
					Loading of Batteries   
					1.Cutting hose   
					2.Removing burr   
					Hose dia.   
					Size(mm)   
					0.8-1.5   
					1.0-1.8   
					1.2-2.0   
					Load the batteries as illustrated in the drawing below:   
					6.35 mm(1/4")   
					9.52 mm(3/8")   
					12.7 mm(1/2")   
					Liquid hose   
					Gas hose   
					Remove Battery Cover:   
					4.Expand Hose   
					3.Put on nut   
					Slightly press   
					and push down the cover. Then , as the drawing, hold the upper end of   
					the remote controller with left hand, and slightly hold the cover with right hand, push slightly in   
					the arrow direction to remove the battery cover .   
					A 
					Refrigeration Oil   
					Piping Connection   
					Hose Expander   
					Connector Nut   
					Load Batteries:   
					1. Connecting Method   
					Be sure that the loading is in line with the   
					+ 
					/ 
					- 
					as illustrated.   
					To ensure the efficiency,the pipe should be as short as   
					possible.   
					Put back Cover:   
					Apply refrigerant oil at half union and flare nut.   
					To bend a pipe,five the roundness as large as possible   
					not to crash the pipe.   
					Spanner   
					Put back the cover in the reverse procedure.   
					Spanner   
					Confirmation Indicator:   
					When connecting pipe,hold the pipe center to center   
					then screw nut on by hand,refer to the Drawing.   
					If there is no display after pressing the on/off button, reload the batteries.   
					Correct   
					Not Correct   
					Be careful not to let foreign matters,such as sands enter   
					the pipe.   
					Notes: Use two same-typed batteries when loading.   
					cracks on   
					expanded   
					mouth   
					If the remote controller cannot run normally or doesn't work at all, use a sharp pointed   
					Recommended   
					Pipe dia.   
					incomplete too long   
					burr   
					Tilting   
					item to press the reset button (with the mark   
					).   
					Fastening Torque   
					Liquid pipe   
					6.35mm(1/4")   
					18 N.m   
					42 N.m   
					50 N.m   
					Gas Pipe 9.52mm(3/8")   
					Gas Pipe 12.7mm(1/2")   
					26   
					7 
				Operation   
					Installation   
					1. Installation Localization   
					2. Indoor Unit Mounting Plate Localization   
					3. Drill through Wall   
					Small Hints:   
					Remove the batteries in case the unit won't be in use for a long period.   
					The remote controller will be self-checked after loading the new batteries by displaying   
					all the symbols and resume working very soon.   
					4. Connect Indoor Unit   
					5. Install Indoor Unit   
					6. Install Outdoor Unit   
					Health Operation   
					1. After turning on the air conditioner, set to the desired mode:   
					The remote controller displays the mode selected, the power   
					light on the indoor unit lights up.   
					2. Set Healthy Operation:   
					ion   
					Press the Health button once   
					is displayed and   
					ion   
					the power or healthy operation indicator turns from orange   
					color to green.   
					C 
					7. Connect Outdoor Unit   
					8. Drain Out   
					9. Check Drainage   
					TEMP   
					Now the air conditioner is operating the healthy function,   
					meanwhile the anion generator in the indoor unit begins to   
					release anion to clean the air and eliminate dust.   
					3. Cancel Healthy Operation:   
					ON/OFF   
					SWING   
					1 
					MODE   
					TIMER   
					FAN   
					Press the button Health again to stop the health   
					display, then the healthy operation stops.   
					HEALTH   
					POWER   
					2 
					3 
					RESET   
					Notes: When the fan in the indoor unit does not work, the health   
					lamp lights up, but the anion generator does not release   
					anion.   
					10. Check Installation   
					11. Trial Operation   
					12. Wind up Pipes   
					Brief Introduction to Health Operation   
					The anion generator in the air conditioner can generate a lot of   
					anion to effectively balance the quantity of posion and anion in   
					the air and also to kill bacteria and speed up the dust sediment   
					in the room and finally clean the air in the room.   
					The step 4 and step 5 above can be adjusted according to the practical situation.   
					This procedure is a reference to the installation person and customer, it can be adjusted according   
					to the practical situation.   
					8 
					25   
				Installation   
					Operation   
					To enable the air conditioner to work well, please install it as required by this manual.   
					When moving the air conditioner, please don't scratch the shell.   
					Cooling / Dehumidifying/Heating Operation   
					Recommended Modes:   
					The max. length of the connection pipe is 15 meters, and the max. height difference between the   
					indoor unit and outdoor unit is 7 meters for AS122 AVARA/AU122 ACARA(HSU-12H03(DB))   
					AS122AYARA/AU122ACARA(HSU-12HA03(DB)) and 5 meters for AS102ALARA/AU102ACARA   
					(HSU-10H03(DB)) AS102AMARA/AU102ACARA(HSU-10HA03(DB)).   
					Cooling mode for summer;   
					Heating mode for winter;   
					Dehumidifying mode for spring and fall.   
					Please keep this manual carefully for maintenance and installation.   
					1. Turn on the Air Conditioner   
					After installation, please operate the air conditioner as per this manual.   
					Press On/Off button to start the air conditioner;   
					Previous operation status appears on display;   
					working method indicator lights up.   
					Electrical Requirements   
					A specialized power supply wire, which shall be installed by a competent person as per the rules of   
					the national standard.   
					2. Select Operation Mode   
					C 
					Power supply socket must be close to the air conditioner. And the socket must have an earth to   
					make the air conditioner be grounded through the power supply socket.   
					If the power supply wire is damaged, it must be replaced by the manufacturer or its service center or   
					professional person.   
					Press mode button, For each press, mode changes as follows:   
					TEMP   
					Cooling   
					Dehumidifying   
					Heating   
					3 
					Power supply wire parameters:3 1.5mm2 for AS102AMARA AU102ACARA(HSU-10HA03(DB))   
					AS102ALARA AU102ACARA(HSU-10H03(DB)), AS122AVARA AU122ACARA(HSU-12H03(DB))   
					AS122AYARA AU122ACARA(HSU-12HA03(DB)).   
					ON/OFF   
					1 
					6 
					When the compressor operates as the panel displays, working   
					method indicator on indoor unit lights up. During heating,   
					if the outdoor unit frosts, the machine will stops heating   
					automatically to defrost , meanwhile neither of the indoor   
					unit fan and outdoor unit fan will work.   
					MODE   
					TIMER   
					SWING   
					FAN   
					2 
					4 
					5 
					Connection wire parameters:3G1.5mm2+1 0.75mm2.   
					POWER   
					HEALTH   
					Hose Selection   
					RESET   
					description   
					Liquid hose   
					Size   
					6.35mm(1/4")   
					3. Select Temperature Setting   
					Press Temp. button   
					AS122AVARA   
					AU122ACARA   
					AS122AYARA   
					AU122ACARA   
					(HSU-12H03(DB)) (HSU-12HA03(DB))   
					12.7mm(1/2")   
					Each press increases by 1   
					Each press decreases by 1   
					; 
					. 
					Gas hose   
					When Unit operation, the room temperature will be the same with   
					temperature display on LCD.   
					AS102ALARA   
					AU102ACARA   
					(HSU-10H03(DB)) (HSU-10HA03(DB))   
					AS102AMARA   
					AU102ACARA   
					9.52mm(3/8")   
					4. Fan Speed Selection   
					Notes: After installation, please confirm that the refrigerant is not leaked.   
					Press Fan button, each press change the fan speed as follows:   
					Auto   
					Hi   
					Med   
					Lo   
					AUTO   
					The fan works at the displayed speed.   
					Hints:   
					The remote controller can remember the working status of each time. Each time when you press   
					the Turn On/Off button, the air conditioner will work at the previous status.   
					24   
					9 
				Operation   
					Installation   
					Installation Tools   
					1. Screw Driver (flat head, wabbler, triangle)   
					2. Steel Saw   
					5. Adjustment of Air Flow Direction   
					After selecting the mode, swing louver will automatically be opened to the position as the drawing   
					indicates:   
					3. 60mm Drill   
					4. Inner Hexagon Spanner   
					5. Shifting Spanner   
					6. Spanner (14,17,19, 27 mm)   
					7. Pipe Cutter   
					Horizontal   
					Cooling Mode   
					Approx.10o   
					Heating Mode   
					Approx.60o   
					8. Pipe Expander   
					9. Knives   
					Up and Down Adjustment (with remote controller)   
					10. Clippers   
					Press   
					swing button once , the swing louver will swing automatically within the range as   
					11. Leakage Checker or Soap Liquid   
					12. Measuring Tape   
					13. Scraper or File   
					indicated in the drawing; press the button again, the swing louver will stop at the current position.   
					The remote controller will remember the current swing position, and each time when you turn   
					on the air conditioner, the swing louver will automatically stop at the position set previously.   
					14. Refrigeration Oil   
					Self-contained Accessories   
					No.   
					Name of Non-   
					Parts adhesive   
					Tape   
					A 
					B 
					C 
					D 
					E 
					F 
					G 
					Adhesive Connecting Heat   
					Gypsum   
					Drain Hose Pipe Clip   
					o 
					Tape   
					Hose   
					Insulation Powder   
					Material   
					Approx.   
					10   
					Cooling approx.450   
					Heating approx.600   
					Notes:   
					Accessories Delivered with Your Air Conditioner   
					Please check if your unit is delivered with the following accessories.   
					When cooling or dehumidifying, do not let the swing louver be downward for long time,   
					otherwise the outlet would be dew and leak water. Even if the louver is downward for long   
					time, after one hour, it will be automatically moved to the position which is 10o to   
					horizontal position. Don't turn the louver manually, otherwise it would work abnormally. If   
					the swing louver works abnormally, turn off the unit, then turn on again, adjust it with the   
					remote controller.   
					No.   
					1 
					Remote   
					controller   
					2 
					3 
					4 
					Shape   
					Batteries   
					Mounting plate   
					Drain Hose   
					Left and Right Adjustment(manual)   
					As the drawing below, turn the vertical louver to adjust the left and right air flow direction.   
					Qty   
					1 
					2 
					1 
					1 
					No.   
					Notes:   
					5 
					6 
					7 
					8 
					9 
					10   
					When the humidity is very high, if all the horizontal   
					Shape   
					Pipe clip   
					Expansion Putty   
					Screw &   
					Bushing   
					Cement Steel   
					Nail   
					Drain Elbow   
					Connection   
					Pipe   
					louvers are turned left or   
					outlet would leak water.   
					right,   
					the   
					6. Turn off   
					4 
					50   
					Press ON/OFF button to turn off the unit; all the displays disappear from LCD and all the lamps   
					on indoor unit go out. And the swing louvers will all be closed automatically.   
					Qty   
					1 
					6 
					1 
					8 
					1 
					1 
					Notes:   
					Hints:   
					After turning off, the unit must not be restarted until 3 minutes later to protect the system.   
					No.   
					11   
					12   
					13   
					Shape   
					Piping Hole Rubber   
					Cushion   
					Connection   
					Wire   
					As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more   
					helpful for a better air circulation.   
					Cover   
					As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful   
					for a better air circulation.   
					Be careful not to catch cold when cold air blows downward.   
					Qty   
					1 
					4 
					1 
					10   
					23   
				Installation   
					Operation   
					Installation Drawing for Indoor and Outdoor Units   
					Time Set Operation   
					With the time set function, the air conditioner can be turned on and off automatically at your   
					set time.   
					You can let your air conditioner be turned on or off automatically after you wake up in the morning,   
					before you come back from work in the evening, or after you fall asleep at night.   
					Mounting Plate   
					1. After turning on the air conditioner, select your desired mode.   
					The operation mode is displayed on the LCD of the remote controller, and the working method   
					indicator on the indoor unit lights up.   
					2. Timer Setting   
					Press TIMER button to change the timer mode, each press makes   
					the timer mode change in the following sequence:   
					Piping Cover   
					No Display   
					OFF   
					ON   
					Timer Off   
					Timer On   
					Insulating Material   
					C 
					The timer mode displays off or on   
					. 
					ON   
					H 
					The time displayed indicates the time set last time.   
					The timer mode on the indoor unit lights up.   
					TEMP   
					Insulating Material   
					Notes: Selecting No Display cancels the timer mode.   
					Piping Layout   
					ON/OFF   
					SWING   
					1 
					3. Time Setting   
					FAN   
					MODE   
					TIMER   
					Left   
					Right Back   
					Right   
					Non-adhesive Tape   
					Press TIMER button:   
					Every time the button is pressed, time increases one hour.   
					If the button is kept depressed, time will change quickly.   
					Every time the button is pressed, time decreases one hour.   
					If the button is kept depressed, time will change quickly.   
					Time can be adjusted within 12 hours . Time will be shown on   
					LCD.   
					2 
					3 
					POWER   
					HEALTH   
					Down   
					RESET   
					Pipe Clip   
					Connection Wire   
					The time setting is to automatically turn on or off the air   
					conditioner a certain number of hours later   
					Insulating Material   
					Notes:   
					After the batteries are replaced, the time set resumes as below:   
					Time set off for 1 hour;   
					Drain Hose   
					Time set on for 6 hours.   
					If necessary, time can be reset; after power goes out, time   
					should be reset.   
					Valve Cover   
					Cancel Timer Mode   
					Just press TIMER button until TIMER mode disappears on LCD.   
					22   
					11   
				Operation   
					Trouble Shooting   
					Super Mode Operation   
					Insufficient Cold Air or Hot Air   
					When you need to cool or heat your room rapidly, you can use this function.   
					Has the mode been selected correctly?   
					Is the dust filter too dirty? (it should be cleaned   
					once every two weeks)   
					Set Super Mode Operation :   
					Press the POWER button each time the display will vary in the following sequence:   
					No Display   
					Stop at   
					. 
					Has the inlet or outlet been blocked?   
					Is the door or window open?   
					At the state of Super Mode Operation ,when cooling, the temperature will be 4 lower than   
					the temperature set, and the fan will automatically run at high speed for 15 minutes, then return to   
					the previously set state;when heating, the temperature will be 6 higher than the temperature set ,   
					and the fan will automatically run at mid speed for 15 minutes, then return to the previously set state.   
					Cancel Super Mode Operation:   
					Press the POWER button twice until the   
					AUTO   
					C 
					display disappears.   
					Insufficient Cold Air?   
					TEMP   
					Soft Mode Operation   
					Is there any other hot   
					resources in the room?   
					Is the sun light directly sent   
					into the room?   
					Are there many people in the   
					room?   
					When you need silence, you can use this function.   
					ON/OFF   
					Set the Soft Mode Operation:   
					MODE SWING   
					TIMER   
					FAN   
					Press the POWER button each time the display will   
					vary in the following sequence:   
					No Display   
					HEALTH   
					POWER   
					RESET   
					Stop at   
					. 
					At this state, the fan speed is Low   
					. 
					Cold Air is Blew out (during heating operation)   
					Cancel Soft Mode Operation:   
					Press POWER button once until the display disappears.   
					Is the unit under heating operation?   
					Hints:   
					When at the state of Super Mode Operation , the room temperature would not be even. And long   
					time soft mode operation would make the room temperature neither too cold nor too hot.   
					Power Failure Resume (to be applied for a necessary situation) (only for the models:AS102ALARA   
					AU102ACARA(HSU-10H03(DB)) AS122AVARA AU122ACARA(HSU-12H03(DB)) AS102AMARA   
					AU102ACARA(HSU-10HA03(DB)) AS122AYARA AU122ACARA(HSU-12HA03(DB)))   
					After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is   
					working, it will resume the previous working state when the power is supplied again .   
					If, after the above-mentioned checks are made and treated accordingly, the air conditioner still   
					cannot work normally or one of the following facts are found, please stop the operation and   
					contact your local service center:   
					Notes: When a power failure suddenly occurs during the air conditioner is working after the power failure   
					resume is set, if the air conditioner will not be used for a long time, please cut off the power supply to   
					prevent its operation from being resumed after the power is supplied again, or press the On/Off   
					button after the power comes again.   
					Fuse or circuit breaker often breaks;   
					Water is leaked during cooling and dehumidifying;   
					Working abnormally or abnormal sound is heard.   
					12   
					21   
				Trouble Shooting   
					Operation   
					Emergency Operation & Test Operation   
					When your remote controller is lost or cannot be used, the unit can be operated with a   
					function of emergency operation.   
					Air does not blow or the fan speed cannot be   
					changed during the dehumidifying mode.   
					During the dehumidifying operation, when the   
					room temperature is less than 2 higher than   
					the temperature set, the air conditioner will   
					operate at low fan speed intermittently   
					regardless to the fan speed set.   
					The test operation can be applied when the cooling test operation is carried out under the   
					room temperature of 16   
					. 
					Emergency Operation   
					It can only be used when the remote controller is lost or damaged.   
					Turning on   
					This results from removal of the frost   
					accumulated on the outdoor unit (Defrosting   
					operation).   
					Water or steam generates from the outdoor unit   
					during heating.   
					Press the emergency manual button, you will hear a sound Hua , then the emergency   
					operation begins. This time the power or healthy operation indicator lamp on the indoor   
					unit lights up.   
					The air conditioner will automatically run as the mode below:   
					indoor temp   
					Temp set   
					Timer   
					Air speed   
					Mode   
					Health   
					Operation   
					Above 23   
					Below 23   
					26   
					23   
					No   
					No   
					Auto   
					Auto   
					Cooling   
					Heating   
					No   
					No   
					To eliminate the afterheat, the fan in the indoor   
					unit will still operate for a while after the unit   
					automatically stops.   
					During heating, the fan in the indoor unit still   
					works even after the unit operation stops.   
					During emergency operation, the temperature set and air speed   
					cannot be changed. Besides, the dehumidifying and timer operation   
					cannot be operated either.   
					It is due to the accumulation of anion, which   
					can be cleaned after the unit is turned off. The   
					sound "Si Si" is due to generation of anion.   
					There would be sooting around the outlet and a   
					sound Si Si would be heard.   
					Turning Off(Cancel Emergency Operation)   
					Press the Emergency Manual Operation button, you will hear a   
					sound Hua , then all the indicators will go out .   
					Cancel Emergency Operation with Remote Controller   
					Press the On/Off button, you will hear a sound Hua , then   
					the air conditioner will work as the mode indicated on the remote   
					controller.   
					Please check your air conditioner as the procedure below before contacting the local maintenance   
					center for after sales service:   
					The air conditioner cannot be started   
					Is power switch on?   
					Is power supply normal?   
					Is the leakage breaker tripped?   
					Test Operation   
					This is for test cooling operation under 16 indoor temperature.   
					It cannot be used under normal condition.   
					Power cut?   
					ON   
					Turning On   
					OFF   
					Keep pressing the Test Manual button button for 5 seconds,   
					you will hear sound Hua   
					Hua", then release the pressing ,   
					Please switch off the power   
					supply immediately and   
					then the test operation begins. Now the unit works under Hi   
					air speed, and the power or healthy operation indicator on the   
					indoor unit lights up.The air conditioner will be automatically   
					turned off after test operation lasts 30 minutes.   
					The power switch is not on the   
					contact the local maintenance   
					center.   
					position ON   
					. 
					Turning Off (Cancel Test Operation)   
					Press the Test manually button , you will hear a sound Hua   
					then all the indicators on the unit will go out.   
					, 
					Cancel Test Operation with Remote Controller   
					Press the On/Off button, you will hear a sound Hua , then   
					the air conditioner will work as displayed on remote controller.   
					20   
					13   
				Notes for Safety   
					Trouble Shooting   
					The followings are not malfunction:   
					Water flowing sound is heard.   
					The power supply plug must have the earth line After electric wiring , the air conditioner shall   
					to ensure that the air conditioner may be be electrified to check for electric leakage.   
					grounded effectively through the power supply   
					When the air conditioner is started, when the   
					compressor starts or stops during operation or   
					socket. Non-grounding or incomplete grounding   
					when the air conditioner is stopped.   
					it   
					would result in electric shock.   
					sometimes sounds shuru shuru or gobo   
					gobo . It is the flowing sound of the refrigerant,   
					and it is not a trouble.   
					This is caused by heat expansion or contraction   
					of plastics.   
					Cracking sound is heard.   
					Air which blows out from the indoor unit   
					sometimes smells.   
					It smells.   
					The smell results from residents of tobacco   
					smoke or cosmetics stuck inside of unit.   
					Clean the dust filter periodically:   
					Use the fuse of required capacity:   
					Never use steel wire or copper wire to take   
					place of the fuse.   
					Blockage of the dust filter would reduce the   
					cooling and heating effect, consume more   
					power, water would be leaked during cooling,   
					and other failures would also occur.   
					During the cooling and dehumidifying   
					operation, a thin white fog would be sprayed   
					out of the indoor unit. It is a watery fog formed   
					by a condensed air blew out of the unit.   
					During operation, white fog comes out of   
					indoor unit.   
					Fuse   
					To prevent frost from being accumulated on the   
					indoor unit heat exchanger, it is sometimes   
					automatically switched to the Fan Mode but it   
					will soon be returned to the cooling mode.   
					During cooling mode, it is automatically   
					switched to Fan mode.   
					Steel wire Copper wire   
					The air conditioner cannot be restarted soon   
					after it stops.   
					This is due to its self-protection function,   
					therefore the machine cannot work until three   
					minutes later.   
					Never install the air conditioner where the   
					flammable gas is easily leaked.   
					Never connect the earth with the gas pipe,   
					water pipe, lightening arrester, or phone line.   
					Wait for three minutes   
					14   
					19   
				Maintenance   
					Notes for Safety   
					Maintenance after Season of Use   
					Do not spray any paint or insecticide on the air   
					Conditioner.   
					Turn on the machine and let it operate for half a day under the status of sending air in   
					a sunny day so as to make the inside of the   
					air conditioner fully dry.   
					Insecticide   
					Paint   
					Clean the dust filter, the indoor unit, and outdoor   
					unit, then cover it.   
					Never pour water on the indoor unit.   
					Keep the inlet and outlet of the indoor unit   
					unblocked.   
					Maintenance before Season of Use   
					Check the inlet and outlet of the outdoor unit,   
					see if they are blocked.   
					When the louver is being swung, never touch   
					the outlet or put anything into the air grille.   
					Operate the unit with the remote controller.   
					The dust filter must be installed to ensure the   
					air filter to be clean,otherwise dust would enter   
					to damage the machine or cause failure.   
					The instructions with this warning mark must be carried out strictly, for they are all   
					concerned with safety of the product or human beings.   
					The instructions with this prohibiting mark must be completely forbidden, otherwise   
					the product would be damaged or the human being would be injured.   
					18   
					15   
				Maintenance   
					Maintenance   
					Clean the Air Conditioner   
					Installation and Replacement of Air Filter   
					Do not clean it with hot water   
					or detergent   
					Do not touch the machine with   
					wet hands   
					Turn off Power   
					1. Open the inlet grill as drawing:   
					2. Remove the dust filter and slightly push the filter upward then pull downward.   
					Open the inlet grill upward   
					Dust Filter   
					3. Install the air filter by inserting it into left and right frames with the white side upward.   
					Remove the dust filter:   
					Slightly push it upward then   
					Pull it downward   
					Air Filter   
					4. Install back dust filter   
					Left filter and right filter are different in shape, so never make it wrong.(dust filter must be   
					installed).   
					Clean the Dust Filter:   
					Clean the dust filter with water or vacuum cleaner,   
					When the filter is too dirty , clean it with detergent   
					or medium soap liquid. Then flush it with water and   
					dry it in sunshine. Finally fix it back.   
					Left   
					Right   
					Remove the Old Air Filter   
					Notes:   
					Do not clean the dust filter with water higher than   
					40 , otherwise it would be damaged. Clean the dust   
					filter gently and carefully.   
					Replace Air Filter   
					Install Air Filter   
					>40   
					Notes: The air filter is optional. Please approach the nearest local maintenance center to buy   
					the air filter according to the replacement time in Air Filter Instructions.   
					Clean the Indoor Unit and Outdoor Unit:   
					Clean it with wet cloth or medium detergent, then   
					clean with dry cloth. The water cannot be higher   
					than 40 , otherwise the unit would be deformed or   
					discolored. And never clean it with insecticide or   
					other chemical detergent.   
					Hints:   
					This model of air conditioner falls into two types: one is with a multiple light catalysis air filter,   
					the other with an air filter without multiple light catalysis. So the maintenance should be done   
					accordingly:   
					>40   
					The multiple light catalysis air filter shall be put in sunshine once every half a year (8 hours each   
					time), while the air filter without the light catalysis shall be replaced every half a year, which can   
					be purchased in the local service center.   
					16   
					17   
				 |