PCC COMMERCIAL
PACKAGED AIR CONDITIONER
PRODUCT SPECIFICATIONS
The PCC Commercial packaged air conditioner
features combination electric heat/electric cooling
with dual high-efficiency scroll compressors. This unit
contains totally enclosed, permanently lubricated
outdoor fan motors and is designed for over/under or
downflow applications.
Standard Features
•
Dual high-efficiency scroll compressors with internal
motor protection for 2-stage cooling
Totally enclosed, permanently lubricated outdoor fan
motors
•
•
•
•
Enhanced copper tube/aluminum fin coils
Fully charged R-22 systems
Belt-driven, variable-pitch sheave permits multi-
speed adjustment
•
•
•
•
•
•
•
Expansion valve evaporator coil
Time delay for compressors sequence
Compressor grommets for vibration isolation
Two independent condenser coils for two-stage operation
High- and low-pressure controls on all systems
Mild ambient switch
10.3 EER
Centrifugal fan for quiet and efficient operation
Cabinet Features
7½ TO 10 TON
•
Heavy-gauge, zinc-coated steel cabinet with weather-
resistant powder-paint finish
•
•
•
Fully insulated with blankets of insulation
Vertical discharge with removable grilles
Control box and compressors easily accessible from
side access panels
COOLING CAPACITY: 86,000 - 116,000 BTU/H
•
•
Base rails with fork slots for convenience
of handling and added rigidity
Galvanized steel, powder-coated drain pan with ¾”NPT
condensate connection
•
•
•
Factory wiring conveniently arranged to install accessories
Filters are provided with unit (2”disposable)
When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for
hurricane-type winds
SS-GPCC
4/09
Supersedes 6/08
PRODUCT SPECIFICATIONS
SPECIFICATIONS
PCC090-3A
PCC090-4A
PCC120-3A
PCC120-4A
Cooling Capacity
Total BTU/h
86,000
63,600
10.3
86,000
63,600
10.3
116,000
85,000
10.3
116,000
85,000
10.3
Sensible BTU/h ¹
EER ²
IPLV ³
10.7
10.7
10.7
10.7
Indoor Blowers (2)
Type
Belt
12” x 12”
3,000
1½
Belt
12” x 12”
3,000
1½
Belt
12” x 15”
3,800
3
Belt
12” x 15”
3,800
3
Wheel (D x W)
Indoor Nominal CFM
Horsepower
Evaporator Coil (1)
Face Area (ft²)
11.2
3/ 16
11.2
3/ 16
14
14
Rows Deep/ Fins per Inch
Tube Diameter - Material
Filter Size (ft²) / Quantity
3/ 16
3/ 16
⅜” - Copper
––
⅜” - Copper
––
⅜” - Copper
16 x 25 x 2 / 3
20 x 25 x 2 / 3
⅜” - Copper
16 x 25 x 2 / 3
20 x 25 x 2 / 3
25 x 25 x 2 / 3
25 x 25 x 2 / 3
Condenser Fans (2) / Coil (1)
Horsepower
½
24”
½
24”
½
24”
½
24”
Fan Diameter
Outdoor Nominal CFM
Face Area (ft²)
5,500
5,500
6,400
6,400
15.6
15.6
23.8
23.8
Rows Deep/ Fins per Inch
Tube Diameter - Material
Electrical Data
2/ 21
2/ 21
2/ 21
2/ 21
⅜” - Copper
⅜” - Copper
⅜” - Copper
⅜” - Copper
Voltage-Phase
208/230-3
12.5/ 88
4.2
460-3
5.9/ 44
2.0
208/230-3
17.4/ 123
8.4
460-3
6.8/ 49.5
4.2
Compressor RLA/ LRA
Indoor Blower FLA
Outdoor Blower FLA
Min. Circuit Ampacity 4
Max. Overcurrent Device 5
Operating Weight (lbs)
Ship Weight (lbs)
2.6
1.3
2.6
1.3
38.1
18.2
54.5
22.5
60 amps
980
30 amps
980
70 amps
1,270
35 amps
1,270
1,290
1,000
1,000
1,290
¹
²
Sensible capacity is gross, with no deduction for indoor motor heat
BTU/Watt @ 80/ 67° F inside; 95° F outside air
IPLV = Integrated Part Load Valve
³
4
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
HACR breakers may be used in place of fuses up to 60 amps
5
SS-GPCC
3
PRODUCT SPECIFICATIONS
DIMENSIONS
ꢀꢁꢂꢃꢄꢅꢆ ꢇꢈꢄꢉꢅꢊꢆꢂꢋꢁꢇ
ꢁꢂꢃꢄꢅꢆꢇꢈꢀꢉꢆꢊꢋꢌꢍꢎꢇꢃꢅꢌꢆꢊꢏꢀ
ꢌꢍꢂꢄꢎꢍꢏꢃꢆ ꢇꢈꢄꢉꢅꢊꢆꢂꢋꢁꢇ
ꢁꢐꢌꢅꢑꢀꢂꢌꢒꢓ ꢀꢔꢊ!ꢅꢃꢓꢓꢒ ꢀ
ꢀ"ꢄꢄꢒ!!ꢆꢇꢈꢏꢀ
#ꢀ
#ꢀ
B
C
A
Unit Size
Height
Supply Air Return Air
17 /16
PCC090-X
6
12½
36
ꢀ
13
PCC120-X
52
20¼
25 /16
X = Electrical Designation
4
SS-GPCC
PRODUCT SPECIFICATIONS
DIMENSIONS—ELECTRICAL CONNECTIONS
1. Main power entrance location
2. Control wiring entrance location
3. Optional field installed internal disconnect switch
4. Knockout not used on electric heat units
Model
PCC090-X
PCC120-X
A
B
6⅛
7⅞
22⅛
23⅞
X = Electrical Designation
SS-GPCC
5
PRODUCT SPECIFICATIONS
COMPONENT PRESSURE DROPS
Electric
Heat
Medium EFF. Economizer Return
Model
CFM
Wet Coil
Filters
Air Damper
2,600
3,000
3,400
3,600
4,000
4,400
0.06
0.06
0.07
0.05
0.05
0.05
0.03
0.04
0.05
0.05
0.06
0.08
0.03
0.04
0.05
0.03
0.04
0.04
0.14
0.14
0.18
0.14
0.14
0.14
PCC090-X
PCC120-X
COOLING CAPACITY DATA — PCC090-X @ 3,000 CFM
75 ˚F DB
80 ˚F DB
85˚F DB
90 ˚F DB
EVAP.
EAT
AMB. ˚F
KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS
61 WB
64 WB
67 WB
70 WB
73 WB
61 WB
64 WB
67 WB
70 WB
73 WB
61 WB
64 WB
67 WB
70 WB
73 WB
61 WB
64 WB
67 WB
70 WB
73 WB
61 WB
64 WB
67 WB
70 WB
73 WB
7.6
7.7
7.7
7.8
7.8
7.8
8.0
8.1
8.1
8.2
8.2
8.3
8.4
8.4
8.5
8.5
8.6
8.7
8.8
8.9
8.9
8.9
9.1
9.1
9.4
83.8
88.7
94.5
72.1
63.3
54.6
7.6
7.7
7.7
7.8
7.8
7.9
8.0
8.1
8.1
8.2
8.3
8.3
8.4
8.4
8.5
8.6
8.6
8.7
8.8
9.0
8.9
8.9
9.1
9.1
9.4
85.7
88.7
94.5
84.8
77.9
69.2
7.7
7.7
7.7
7.8
7.8
8.0
8.0
8.1
8.1
8.2
8.3
8.3
8.4
8.4
8.5
8.6
8.6
8.7
8.8
9.0
9.0
9.0
9.1
9.2
9.4
90.6
90.6
94.5
90.6
90.6
82.8
7.7
7.7
7.8
7.8
7.9
8.0
8.0
8.1
8.2
8.4
8.4
8.4
8.4
8.4
8.6
8.7
8.7
8.7
8.8
9.0
9.1
9.1
9.1
9.2
9.4
95.5
95.5
95.5
100.3
106.2
94.5
94.5
94.5
98.4
103.3
93.5
93.5
93.5
96.4
101.3
91.6
91.6
91.6
94.5
99.4
89.6
89.6
89.6
92.5
98.4
95.5
95.5
95.5
88.7
79.9
94.5
94.5
94.5
87.7
78.9
93.5
93.5
93.5
87.7
78.9
91.6
91.6
91.6
85.7
77.9
89.6
89.6
89.6
85.7
77.0
85
100.3 45.8
106.2 37.0
100.3 60.4
106.2 51.6
100.3 74.0
106.2 65.3
81.8
86.7
92.5
97.4
71.1
62.4
53.6
44.8
83.8
87.7
92.5
97.4
83.8
77.0
68.2
59.4
88.7
88.7
92.5
98.4
88.7
88.7
82.8
74.0
90
95
103.3 36.0
103.3 50.7
105.2 64.3
80.9
85.7
90.6
96.4
71.1
62.4
53.6
44.8
82.8
85.7
90.6
96.4
82.8
76.0
68.2
58.5
87.7
87.7
90.6
96.4
87.7
87.7
81.8
73.1
101.3 35.1
101.3 49.7
101.3 64.3
78.9
83.8
88.7
94.5
99.4
77.0
81.8
86.7
91.6
98.4
70.1
61.4
52.6
43.8
35.1
69.2
60.4
51.6
42.9
34.1
80.9
83.8
88.7
94.5
99.4
79.9
81.8
86.7
91.6
98.4
80.9
76.0
67.2
58.5
48.7
79.9
75.0
66.3
57.5
48.7
86.7
86.7
88.7
94.5
99.4
84.8
84.8
86.7
92.5
98.4
86.7
86.7
80.9
72.1
63.3
84.8
84.8
79.9
71.1
62.4
100
105
NOTES:
1
Capacities are gross and are based on 230, 460 operation. 208-volt AMB
Ambient Air Temperature
Entering Air Temperature
Evaporator Dry Bulb EAT
Evaporator Wet Bulb EAT
Evaporator Airflow Ft.³/min (Table 9a)
1,000 Watts
operation must be derated by 0.98. Gross capacities do not include
EAT
DB
WB
evaporator motor heat.
kW is for entire unit
See table for capacity correction factors at other than nominal CFM. CFM
kW
2
3
SHADED AREA REPRESENTS 100% SENSIBLE COOLING
MBHT 1,000 BTU/h Total Cooling
MBHS 00 BTU/h Sensible Cooling
6
SS-GPCC
PRODUCT SPECIFICATIONS
COOLING CAPACITY DATA (CONT.) — PCC120-X @ 4,000 CFM
75 ˚F DB
80 ˚F DB
85 ˚F DB
90 ˚F DB
EVAP.
EAT
AMB. ˚F
KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS KW MBHT MBHS
61 WB 10.2 115.9 99.7
64 WB 10.3 122.6 87.6
67 WB 10.3 130.7 75.4
70 WB 10.6 138.8 63.3
73 WB 10.6 146.9 51.2
61 WB 10.6 113.2 98.3
64 WB 10.8 119.9 86.2
67 WB 10.9 128.0 74.1
70 WB 10.9 134.7 62.0
73 WB 11.0 142.8 49.8
61 WB 11.0 111.8 98.3
64 WB 11.1 118.6 86.2
67 WB 11.3 125.3 74.1
70 WB 11.3 133.4 62.0
73 WB 11.5 140.1 48.5
61 WB 11.5 109.1 97.0
64 WB 11.6 115.9 84.9
67 WB 11.7 122.6 72.7
70 WB 11.8 130.7 60.6
73 WB 12.0 137.4 48.5
61 WB 12.0 106.4 95.6
64 WB 12.0 113.2 83.5
67 WB 12.3 119.9 71.4
70 WB 12.3 126.6 59.3
73 WB 12.6 136.1 47.2
10.2 118.6 117.2 10.3 125.3 125.3 10.3 132.0 132.0
10.3 122.6 107.8 10.3 125.3 125.3 10.3 132.0 132.0
85
10.3 130.7 95.6
10.6 138.8 83.5
10.6 146.9 71.4
10.3 130.7 114.5 10.5 132.0 132.0
10.6 138.8 102.4 10.6 138.8 122.6
10.6 146.9 90.3
10.7 146.9 110.5
10.7 115.9 115.9 10.8 122.6 122.6 10.8 130.7 130.7
10.8 121.3 106.4 10.8 122.6 122.6 10.8 130.7 130.7
90
95
10.9 128.0 94.3
10.9 134.7 82.2
11.0 142.8 70.1
10.9 128.0 114.5 10.9 130.7 130.7
10.9 136.1 102.4 11.0 136.1 121.2
11.0 145.5 88.9
11.3 142.8 109.1
11.1 114.5 114.5 11.1 121.3 121.2 11.3 129.3 129.3
11.1 118.6 105.1 11.1 121.3 121.2 11.3 129.3 129.3
11.3 125.3 94.3
11.4 133.4 80.8
11.5 140.1 68.7
11.3 125.3 113.2 11.4 129.3 129.3
11.4 133.4 101.0 11.4 133.4 121.2
11.5 140.1 88.9
11.6 140.1 109.1
11.6 111.8 111.8 11.6 119.9 119.9 11.7 126.6 126.6
11.6 115.9 105.1 11.6 119.9 119.9 11.7 126.6 126.6
100
105
11.7 122.6 93.0
11.8 130.7 80.8
12.2 137.4 67.4
11.7 122.6 111.8 11.7 126.6 126.6
11.8 130.7 99.7
12.2 137.4 87.6
11.8 130.7 118.5
12.2 137.4 107.8
12.0 110.5 110.5 12.2 117.2 117.2 12.3 124.0 123.9
12.0 113.2 103.7 12.2 117.2 117.2 12.3 124.0 123.9
12.3 119.9 91.6
12.3 126.6 79.5
12.6 136.1 67.4
12.3 119.9 110.5 12.3 124.0 123.9
12.4 128.0 98.3
12.6 136.1 86.2
12.4 128.0 118.5
12.6 136.1 106.4
NOTES:
1
Capacities are gross and are based on 230, 460 operation. 208-volt AMB
Ambient Air Temperature
Entering Air Temperature
Evaporator Dry Bulb EAT
Evaporator Wet Bulb EAT
Evaporator Airflow Ft.³/min (Table 9a)
1,000 Watts
operation must be derated by 0.98. Gross capacities do not include
evaporator motor heat.
kW is for entire unit
See table for capacity correction factors at other than nominal CFM. CFM
kW
EAT
DB
WB
2
3
SHADED AREA REPRESENTS 100% SENSIBLE COOLING
MBHT 1,000 BTU/h Total Cooling
MBHS 00 BTU/h Sensible Cooling
COOLING CAPACITY CORRECTION FACTORS
EVAPORATOR MOTOR HEAT
Horse-
power
CFM
-5%
BTU/h
-15%
0.971
0.925
0.985
-10%
0.985
0.952
0.989
STD.
+5%
1.006
1.024
1.004
+10%
1.012
1.048
1.006
+15%
1.019
1.070
1.011
1.5
3
4,650
9,300
Total MBH
Sensible MBH
kW
0.991
0.974
0.995
0
0
0
SS-GPCC
7
PRODUCT SPECIFICATIONS
ELECTRIC HEAT AIR TEMPERATURE RISE
Heater Model
Number of Stages
Output (MBH)
2,600
HKCB20
2
HKCB30
2
HKCB40
2
67.9
24.2
22.5
21.0
19.7
18.5
17.5
16.5
15.7
15.0
14.3
13.7
13.1
12.6
12.1
11.6
11.2
10.8
10.5
135.8
36.2
33.6
31.4
29.4
27.7
26.2
24.8
23.5
22.4
21.4
20.5
19.6
18.8
18.1
17.4
16.8
16.2
15.7
135.8
-
2,800
-
3,000
-
3,200
39.3
37.0
34.9
33.1
31.4
29.9
28.6
27.3
26.2
25.2
24.2
23.3
22.5
21.7
21.0
3,400
3,600
3,800
4,000
4,200
CFM
4,400
4,600
4,800
5,000
5,200
5,400
5,600
5,800
6,000
Notes
•
•
•
Maximum air temperature rise of 40° must not be exceeded.
See table for Electric Heat Kit Availability in various unit sizes.
Air temperature rise is for total heating capacity. Temperature rises at other conditions may be
calculated by using the formula:
Temperature Rise = Output Capacity - BTU/h
1.08 x ft3/min. Airflow
•
•
For altitudes over 2,000’, air temperature rise must be calculated using the formula:
Temperature Rise = Output Capacity - BTU/h
14.4 x ft3/Min. Airflow x Specific Weight of Air
Operation at less than nominal voltages must be derated by the following factors:
460 volt-0.92; 230 volt-0.92; 208 volt-0.75.
HEAT KIT AVAILABILITY
Unit Size
HKCB20
HKCB30
HKCB40
7½
10
X
X
X
X
X
X
X - Heat Kit Available
N/A - Heater Not Available
8
SS-GPCC
PRODUCT SPECIFICATIONS
WIRING DIAGRAM — PCC24-36***
C
Y
- 7 W H
R
O
G
W
E S U F
R
Y
W
G
XFMR R
R
C
XFMR C
C
G
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date schematic.
10
PRODUCT SPECIFICATIONS
WIRING DIAGRAM — PCC42-48***
C
Y
7 - W H
R
O
G
W
E S U F
R
Y
W
G
XFMR
R
R
C
XFMR
C
C
G
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date schematic.
11
PRODUCT SPECIFICATIONS
WIRING DIAGRAM — PCC60***
C
Y
R
O
G
W
2 Y / Y
G
2 C
1 C
3 R
2 R
O
2 W / M E
1 W
2 Y /
Y
G
2 C
1 C
3 R
2 R
O
C
Y
R
O
G
2
/ W M E
1
W
T I K R E T A E H O T
W
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date schematic.
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice
or without incurring obligations. © 2008-2009 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
12
SS-GPCC
|