1
Warnings and Introduction
ReAd And SAve THeSe InSTRUcTIOnS
Important Safety Instructions: Read all instructions before using this humidifier.
• This humidifier may not work properly on an uneven surface. ALWAYS place this humidifier on a firm, level, and water
resistant surface.
• WARnInG: This humidifier emits UVC radiation that may cause eye and/or skin irritation. RG-3. Avoid exposing eyes
and skin to unshielded UVC Lamp.
• cAUTIOn: The UVC Lamp may shatter and cause injury if it is dropped or sustains impact. Wear safety glasses and
gloves when handling the UVC Lamp. Do not use excessive force when handling the UVC Lamp. Dispose of the UVC bulb
in accordance with local or State guidelines as trace amounts of Mercury are present.
• ALWAYS place the humidifier at least six (6) inches away from walls, heat sources, and electrical appliances such as
stoves, radiators, or heaters.
• ALWAYS place the humidifier in an area that is out of the reach of children.
• Before using the humidifier, extend the cord and inspect for any signs of damage. dO nOT use the product if the cord
has been damaged.
• This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized
outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician. dO nOT attempt to defeat or override this safety feature.
• ALWAYS UnPLUG And eMPTY the humidifier when it is not in operation or while it is being cleaned.
• Use only clean, cool tap water when filling the tank. dO nOT use hot water.
• Never add medication of any type to the water tank.
• You should never leave the unit unattended in a closed room. The room can become saturated and leave condensation
on walls and furniture. Always leave a door partially open.
Thank you for purchasing The Ultrasonic Humidifier by Hunter Fan Company. Please read and save these instructions to receive the
maximum benefit and performance from your humidifier.
3
©2010 Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
At A Glance
1
Know Your Humidifier
Tank Handle
Mist Exhaust
Water Tank
Tank Cap
Control Knob
Demineralization
Cartridge Indicator
UVC Indicator
Refill Tank Light
Demineral
UVC
Oꢁ
Reꢀll Tank
Demineralization
Cartridge Reset Button
UVC
Compartment
UVC Bulb
4
44064-01 • 05/06/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Your Humidifier
2
Initial Setup and Operation
Initial Setup:
1. Remove the plastic bag covering from the humidifier.
Tank Handle
2. Unravel and straighten the cord before use.
3. Remove the tank from the humidifier base by grasping the tank handle, Figure
4. If you plan to use a demineralization cartridge, insert it now into the base of
Figure 1
5. If you will be using a vapor pad in the unit, turn the base over and remove the
vapor pad compartment grill. Insert 1 vapor pad into the compartment and
reattach the compartment to the base of the unit. Figure 5.
6. Turn the tank upside down and twist the tank cap counter-clockwise to remove.
7. Fill the unit with clean, cool tap water.
Warning: Never fill the humidifier with hot water.
8. Place the tank cap back on the tank and turn clockwise till secure.
Silver Ion
Demineral
Oꢁ
Reꢀll Tank
9. Seat the tank back into the humidifier base making sure the tank is seated
securely.
Figure 2
Tank Cap
nOTe: Failure to ensure the tank is seated correctly could cause the unit to leak
water from the tank.
10. Plug the humidifier into a wall outlet and start the unit.
Figure 3
Demineralization
Cartridge
Figure 4
Figure 5
5
©2010 Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Your Humidifier
2
Controls
Operation:
Demineral
UVC
Humidity control:
The humidity control allows you to set the amount of humidity you want
the unit to output. The humidity knob is a percentage, ranging from
30% at its lowest to 80% at the highest. Turn the knob clockwise to
increase humidity output. When the humidifier has reached the set
humidity level, it will shut off until the humidity level drops again. To turn
the unit off, turn the the humidity knob past the lowest setting to off.
Oꢁ
Reꢀll Tank
Figure 6
Indicators:
UVC Indicator: When the UVC indicator lights up, it is time to replace the UVC
Bulb in the bottom of the unit. Replacing the bulb will reset the indicator.
Demineral Indicator: When the demineral indicator lights up, it is time to replace
the demineralization cartridge in the base of the unit, if you are using one. Remove
the tank from the unit, and the demineralization cartridge should be sitting inside
the water tray in the bottom. Hold the reset button down under the indicator for a
few seconds until the light goes out to reset.
Refill Tank Indicator: This indicates the tank is out of water. Once you have refilled
the tank with water and set it back onto the unit, the refill tank light will reset.
6
44064-01 • 05/06/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
3
Cleaning and Storage
note: ALWAYS unplug the humidifier from the electrical outlet before cleaning.
NEVER allow water to sit in the tank when not in use.
daily Maintenance:
1. Turn off the humidifier and unplug it from the wall outlet.
2. Remove the tank unit by pulling it straight off the humidifier base.
3. Turn the tank upside down and drain any water into a sink or tub. Shake the
unit gently to remove any remaining water.
4. Rinse the tank thoroughly with water, empty, and wipe with a dry, clean cloth.
5. Wipe the humidifier base with a dry cloth if necessary.
resume use.
Weekly Maintenance:
1. Turn off the humidifier and unplug it from the wall outlet.
2. Remove the tank unit by pulling it straight off the humidifier base.
3. Turn the tank upside down and drain any water into a sink or tub. Shake the
unit gently to remove any remaining water.
4. Fill the Water Tank with a mixture of one (1) gallon of water and eight (8)
ounces of white vinegar. Leave the mixture in the Water Tank for 20 minutes,
giving the Water Tank a shake every few minutes. After 20 minutes, give the
Water Tank a final shake and discard the mixture.
5. Rinse the Water Tank several times with clean water. Leave the Water Tank
Cap off to allow the Water Tank to dry completely.
6. Wipe the surfaces of the main housing with a soft damp cloth.
7. Once all the parts are clean and dry, reassemble the humidifier, refill the
water tank and resume use.
note: The tank has built-in antimicrobial properties to inhibit the growth of
bacteria, mold, and fungi that may affect the water in the tank. Daily and weekly
maintenance is still necessary to prevent the growth of bacteria, mold, and fungi.
end of Season Maintenance:
1. Follow the instructions for weekly maintenance before storing the unit.
2. Ensure all parts are completely dry before storing the unit.
3. Store the unit in a cool dry place.
4. Never store the unit with water in the tank.
7
©2010 Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
3
Replacing the UVC Bulb
Uvc Replacement:
Screws
Your humidifier is equipped with a UVC bulb to help kill germs and bacteria in the
water. This bulb needs to be replaced once a year. These instructions will assist
you with bulb replacement.
1. Turn the humidifier off and unplug it from the wall outlet.
nOTe: Before replacing the UVC bulb, you must empty the water out of the
humidifer.
2. Remove the water tank from the unit and empty any water in the humidifier
base.
Tab
3. Turn the humidifier base over and remove the 2 screws attaching the
Figure 7
4. Grip the tab on the bottom of the UVC compartment and pull straight out.
5. Remove the UVC bulb from the UVC cover by turning counterclockwise ,
nOTe: When handling the new bulb, do not let it come in direct contact with
your hands. Oils from your skin can cause the bulb to fail directly, or lessen its life
expectancy. Use the bag the bulb came in to screw it into the socket on the UVC
cover.
nOTe: If the UVC cover is not installed properly the humidifer WILL nOT
OPeRATe.
Figure 8
6. Insert the 2 screws that hold the UVC cover, and tighten securely.
7. Reassemble the unit and resume operation.
Figure 9
Figure 10
8
44064-01 • 05/06/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Humidifier Assistance
4
Troubleshooting
Problem:
Excessive noise.
Solution:
1. Check the Water Tank to make sure it is properly seated on the base.
2. Check the Water Tank to make sure there are no bubbles when the Water Tank
is full and running. If there are bubbles, turn the unit OFF until the bubbling stops.
When the bubbling has stopped, set the unit to the desired speed.
Problem:
Humidifier not working.
Solution:
1. Make sure the humidity level is not set to OFF.
2. Adjust the humidity level using the Humidity Knob. Once the room reaches the
set humidity level, the humidifier will turn OFF; this is normal.
3. Ensure the UVC bulb compartment is installed properly.
Problem:
Mineral build-up on the Water Tank or Tray.
Solution:
Problem:
Humidity output and water usage decreased.
Solution:
1. Check the Humidistat Knob to make sure it is set to the desired humidity level.
2. Check the Water Tank to make sure there are no bubbles when the Water Tank
is full and running. If there are bubbles, turn the unit OFF until the bubbling stops.
When the bubbling has stopped, set the unit to the desired speed.
3. Clean any components that have mineral build-up. Refer to the section
9
©2010 Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
Humidifier Assistance
4
Service Parts and Support
Service Parts
Part # Part Name Part
Replace
89755-
01-326
Water Tank
G0843-
01-679
Tank Assembly Cap
Demineralization
Cartridge
31954
1 per month
1 per year
30850
UVC Bulb
Technical Support
If you need any assistance with setup, operation, or parts for your new Hunter
Humidifier, please call us, our technical support staff is ready to help!
USA: 1-888-830-1326
canada: 1-866-268-1936
Hours of operation are from 7:00 am to 7:00 pm Monday - Friday and 8:00 am
to 5:00 pm on Saturday, Central Time. You may also contact us over the Internet
at www.hunterfan.com or register your product at www.hunterfan.
com/register and select your product under product registration.
10
44064-01 • 05/06/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Humidifier Accessories
5
Treatments
Model
Product
evaporative
Ultrasonic
vaporizer
Warm Mist
31955
Cleaning Cartridge
31954
31961
Demineralization Cartridge
Vapor Steam
31956
31960
Vapor Pads
Water Treatment Tablets
Notes
11
©2010 Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
6
3 Year Guarantee
The Hunter Fan Company, Inc. makes the following warranty to the original
residential user or consumer purchaser of the ultrasonic humidifier:
If any part of the ultrasonic humidifier fails during the first 3 (three) years from the
date of purchase due to a defect in material or workmanship, we will provide a
replacement part free of charge.
If no replacement part can be provided, we will replace your humidifier.
IF THE ORIGINAL RESIDENTIAL USER OR CONSUMER PURCHASER CEASES
TO OWN THE HUMIDIFIER, THIS WARRANTY AND ANY IMPLIED WARRANTY
WHICH THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS
WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE IS EXPRESSLY LIMITED TO THE PERIOD
OF THE EXPRESS WARRANTY SET FORTH ABOVE.
This warranty is voided if your ultrasonic humidifier is not purchased and used in
the USA or Canada.
This warranty excludes and does not cover defects, malfunctions, or failures of
the humidifier which were caused by repairs by persons not authorized by us,
use of parts, or accessories not authorized by us, mishandling, modifications, or
damage to the humidifier while in your possession, or unreasonable use, including
failure to provide reasonable and necessary maintenance. This warranty does
not cover humidifiers used in commercial applications. There are no express or
implied warranties as to commercial purchasers or users.
To obtain service, contact the nearest Hunter authorized service center or the
Hunter Fan Company Service Department, 7130 Goodlett Farms Pkwy., Suite
400, Memphis, TN 38016, 1-888-830-1326. You will be responsible for
insurance and freight or other transportation to our factory service center. We
will return the humidifier freight prepaid to you. The humidifier should be properly
packaged to avoid damage in transit since we will not be responsible for any
such damage. Proof of purchase is required when requesting warranty service.
The purchaser must present the sales receipt or other document that establishes
proof of purchase.
IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT,
INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS
OF THE PURCHASE PRICE OF THE HUMIDIFIER. YOUR SOLE REMEDY WILL BE
REPAIR OR REPLACEMENT AS PROVIDED ABOVE. SOME AMERICAN STATES
AND CANADIAN PROVINCES DO NOT ALLOW:
• LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS;
• THE EXCLUSION OR LIMITATION OF DIRECT, INDIRECT, SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES;
• THE EXCLUSION OR INVALIDITY OF EXPRESS OR IMPLIED WARRANTIES IF
THE USER CEASES TO OWN THE HUMIDIFIER;
• THE LIMITATION OF THE REMEDIES AND RECOURSES AVAILABLE TO THE
PURCHASER; OR THE INVALIDITY OF AN EXPRESS WARRANTY WHEN A
PRODUCT IDENTIFIED BY BRAND NAME IS NOT USED (UNLESS SPECIFIC
CONDITIONS ARE FULFILLED);
SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO
PROVINCE.
Printed in china and Taiwan
12
44064-01 • 05/06/2010