Hunter Fan Air Cleaner 44350 User Manual

®
SINCE  
1 8 8 6  
44300/44350  
OwnerÕs Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
We are pleased you have selected one of our broad line of home comfort products. Our  
products are manufactured to high quality standards and are designed for years of service.  
We hope you will be satisfied and thank you for buying a Hunter product.  
Table Of Contents  
Installation  
Features  
6
8
Remove Old Thermostat  
Labeling Wires  
10  
14  
14  
System Selector Switches  
Connecting Wires and Mounting Thermostat  
Operation  
Programming/Setting Clock  
Personal Program Schedule  
Reviewing Program Settings  
Manual Overide  
16  
20  
26  
27  
30  
30  
31  
32  
34  
Temperature Span  
Backlighting  
Filter Monitor  
Trouble Shooting Guide  
Typical Wiring Diagrams  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Read This Before Installing Thermostat  
IMPORTANT  
This Hunter Thermostat will not control multi-  
Read the entire installation section of this  
1Owner’s Manual thoroughly before you begin  
to install or operate your Hunter Thermostat.  
stage heating or cooling systems, 110/220 V  
systems, or 3 wire zone systems.  
COMPRESSOR PROTECTION  
• Remove the mylar label from the display  
window.  
The thermostat provides a 4-minute delay  
5after shutting off the compressor before it  
can be restarted. This feature will prevent  
damage to your air conditioner compressor  
caused by rapid cycling. It does not provide a  
delay when there are power outages.  
INSTALLATION  
All installation is normally performed at your  
2thermostat.  
PROGRAMMING  
TEMPERATURE RANGE  
You can practice programming before  
3installing your thermostat by inserting and  
connecting the batteries and following the  
instructions on page 14. This can be done while  
you relax in your favorite chair and is a very  
good way to familiarize yourself with all the  
functions of your Hunter Thermostat.  
Your thermostat can be programmed between  
640°F and 95°F (5°C and 35°C). However, it will  
display room temperatures from 32°F to 99°F (0°C  
and 37°C).  
POWER FAILURE  
Whenever the main power is interrupted or  
7fails, the battery power retains the programs  
and current time.  
OPERATION  
Your Hunter Thermostat is designed to  
4operate with most gas, oil, electric or 2-wire  
hot water heating, and air conditioning systems  
that have 24-volt or millivolt control.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BATTERY WARNING  
CAUTION: The batteries are the only source  
of power used to operate your system. If you  
do not replace the batteries, the display will  
dim and your heating and cooling system will  
stop operation.  
When the batteries are low, the “LOW BATT”  
8indicator on the display will flash. When this  
happens, install new batteries immediately.  
Once the “LOW BATT” indicator appears, the  
thermostat will continue to operate for  
approximately 30 days. (Only alkaline batteries  
should be used in your thermostat.  
Rechargeable batteries have different properties  
which may cause the thermostat to not operate  
properly. Do not use old batteries.) The batteries  
should last one year.  
NOTE: If you plan to be away from the  
premises over 30 days, we recommend that  
you replace the old batteries with new  
alkaline batteries prior to leaving.  
How This Thermostat Works…And Saves You Money  
This thermostat is designed to optimize the use of your heating and cooling equipment. It  
does this by matching your comfort (the temperatures in your home) to your schedule.  
An example:  
6:00 am You wake up. Program 1 has the heat set to 70° (21°C).  
7:30 am You leave for work. The second program turns the heat back to 62° (17°C)  
while you are away.  
5:00 pm You come home. The third program has already warmed your house back  
to 70° (21°C).  
10:00 pm You go to bed. A half hour later, program 4 turns the heat back to 64° (18°C)  
to save energy while you are under the blankets.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
6-7  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
c
Display shows time, day, temperature, program number,  
hold, usage and low battery indicator.  
AM  
PM  
:
88 88 88  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Individual  
Display backlight for viewing in the dark.  
(Feature found only on certain models.)  
pushbuttons for  
raising or lowering  
temperature settings.  
Reset button for  
resetting computer back  
to 12:00 A.M. and  
clearing all programs.  
LIGHT  
Manual switch for  
turning on heating and  
cooling system.  
Manual switch for  
automatic or continuous  
fan operation.  
Soft touch programming  
buttons (see below)  
Battery door for easy access  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For entering minute of day.  
For entering day of week.  
For entering hour  
of day.  
Reviews filter  
usage in  
HOUR  
MIN  
DAY  
hours and  
minutes. Also  
resets filter  
counter to  
zero.  
For reviewing  
and changing  
weekday or  
weekend  
AUTO  
PROGRAM  
PROG  
FILTER  
RETURN  
programs  
PROG  
DAY  
12/24 HRS  
Picks the  
day/days for  
programs  
Changes the clock  
into 12 or 24 hour  
(military) mode.  
(Model 44300)  
Returns  
display to  
current  
time and  
temperature.  
Automatically  
programs  
thermostat for  
weekday and  
weekend  
HOLD/CLEAR button.  
(Model 44350)  
program  
settings.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
8-9  
What You Need  
This thermostat comes with two #8 slotted screws and two wall anchors for mounting. To  
install your unit, you should have the following tools and materials.  
Slotted screwdriver  
Hammer  
Electric drill and 3/16" bit  
Two 1.5V (AA) Size Alkaline batteries  
Remove Old Thermostat  
CAUTION: Do not remove any wiring from existing thermostat before reading the  
instructions carefully. Wires must be labeled prior to removal.  
IMPORTANT! Turn off the power to the furnace at the main power panel or at the furnace.  
Remove existing thermostat cover and thermostat. See Figure 1. Some thermostats will have  
screws or other locking devices that must first be removed. Once wall mounting plate is  
exposed, look for wires.  
If wires are not visible, they may be connected to the back of the wallplate. Again, look for  
screws, tabs, etc. Some models have doors that open to expose wires and mounting screws.  
(See Figure 1).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL HOME THERMOSTATS  
FIGURE 1  
Wall Mounting Plate  
Thermostat  
Cover  
Wall Mounting Plate  
Thermostat  
Cover  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Label Wires  
10-11  
Each wire coming from the wall to the existing thermostat is connected to a terminal point on  
that thermostat. Each of these terminal points is usually marked with a code letter as shown in  
Table A on page 11.  
The number of wires in your system can be as few as two (for heat only systems), as many as  
eight, or any number in between. If you follow the labeling procedures correctly, you do not  
have to be concerned about how many wires there are.  
There is often no terminal marking on the existing thermostat of two wire, heat only systems.  
Do not worry, just connect either of the wires to the RH terminal, then connect the other wire  
to the W terminal to complete the circuit.  
IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE SELF-ADHESIVE LABELS  
PROVIDED TO THE WIRE AS SHOWN IN TABLE A ON PAGE 11. (For example, attach the  
label marked W to the wire which goes to the W or H terminal on your existing thermostat.)  
IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard.  
After labeling wires, disconnect them from the existing  
thermostat terminals.  
Y
G
W
RH  
RC  
Remove existing wallplate. To make sure wires do not fall  
back into wall opening, you may want to tape them to the  
wall.  
If hole in wall is larger than necessary for wires, seal this hole  
so that no hot or cold air can enter the back of the  
thermostat from the wall. This air could cause a false  
thermostat reading.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wire Labeling  
If the code letter on your  
existing thermostat is  
and connect to thermostat  
Terminal shown  
then mark wire  
with label shown  
RH, R,  
VR or 4  
24 Volt  
This table will help you  
match the labels to the  
wires so you can attach  
them to your Hunter  
Thermostat.  
RH  
RED  
RC, VC  
24 Volt Cool  
RC  
RC  
BLUE  
G or F  
Fan  
G
NOTE: Follow the labels  
when connecting wires  
since many installations  
do not follow color  
GREEN  
Y, C or M  
(See Note)  
coding of wires.  
Y
Air Conditioning  
YELLOW  
W or H  
Heating  
W
WHITE  
TABLE A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
12-13  
Wire Labeling  
NOTE: If your thermostat has one wire marked R or RH (4-wire system), then leave  
the jumper wire between the RH and RC terminals. Otherwise, if you have separate  
RH and RC wires (5-wire system), then remove the jumper wire between the RH and  
RC terminals.  
NOTE: Do not connect a Common” wire (sometimes labelled C) to any terminal on  
this thermostat. Tape up the wire and do not use. This wire provides electricity to non-  
battery powered thermostats.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mount Wallplate and Thermostat  
Snap open the wallplate from your thermostat by pressing the release tab on the bottom of  
the thermostat.  
Position wallplate on wall and pull existing wires through large opening. Then level for  
appearance. Mark holes for plastic anchors provided if existing holes do not line up with  
Hunter Thermostat holes.  
Drill holes with 3/16" bit and gently tap anchors into the holes until flush with wall.  
Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws  
provided into wall anchor and tighten. (See Figure 2.)  
Figure 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
14-15  
Selector Switches  
The heating system selector and the F°/C° selector switches are located on the Printed  
Circuit Board.  
Heating system selector  
The heating system selector is a switch on the Printed Circuit Board on the inside of the  
thermostat. The switch is at “HG” position. Leave it in this position if you have a gas  
furnace or an oil burner.  
If you have an electric furnace, test to see whether the heat and fan come on as  
expected. Leave the switch in the “HG” position. If the fan does not come on when the  
thermostat calls for heat, change the switch position to “HE.”  
The system selector has no effect in the cooling mode.  
NOTE: HG” position is for gas and most other systems. HE” position is for certain  
electric systems having a fan relay.  
/C° selector (Fahrenheit/Centigrade)  
Your thermostat is set for F° mode from the factory. In order to  
HE  
HG  
change to C° mode, slide the switch to C° and press reset  
button on front of the thermostat with a paper clip. The reset  
button is located near the display.  
C
F
NOTE: Unless reset button is pressed, the thermostat will  
not change the mode.  
Connect Wires and Mount Thermostat Cover to Wall Plate  
Match and connect the labeled wires to the appropriate coded terminal screws on the  
mounting plate. (See Figure 3, 4.) Ignore any wires which may be present, but which were  
not connected to the old thermostat.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational  
problems with your system or thermostat.  
Push excess wire back into hole to prevent interference with mounting of the thermostat cover.  
Make sure the Function Switch is set at OFF, and the FAN-AUTO Switch is in AUTO.  
Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate.  
Press top of the thermostat body to snap it into the wallplate. (NOTE: Do not force the  
thermostat onto the wallplate, as the terminal pins may be damaged. If it does not  
snap properly, the thermostat may not work.)  
Insert the two AA size batteries, observing the  
polarity marked on the unit.  
Switch on the main power. Press the reset button.  
(See Figure 5.)  
The LCD display indicates the current room  
temperature of your house. If it shows random  
numbers or partial digits, press the reset button  
once again.  
The installation is now complete. Continue reading  
Owner’s Manual for complete operating instructions.  
RH  
G
W
Y
RC RH  
FIGURE 4  
FIGURE 3  
FIGURE 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
16-17  
Remove mylar label covering display  
window.  
If power is interrupted the batteries will  
keep all programs.  
1
2
3
4
When the heating or cooling system is  
actually operating, “HEAT” or “COOL”  
will appear on the display.  
If LOW BATT” indicator appears on the  
display replace the batteries.  
Setting the Time and Day of Week  
When you first install the two AA batteries, the thermostat automatically sets the day and  
time to Monday, 12:00 a.m., shows the current room temperature and is programmed for 68°  
in heat mode and 78° in cool mode. Press the reset button after installing new batteries.  
The first data you should enter is the current time and day of week. As the keys are pressed,  
the display will show the data being entered.  
EXAMPLE:  
If the unit is  
being  
ݗ
ݚݙݘ
 
Initial read-out after pressing  
M T W TH F SA SU  
HEAT COOL  
c
reset button.  
Current room temperature is 72°.  
No indication of program number.  
AM  
PM  
:
installed at  
9:15 p.m.,  
Saturday, to  
set the  
thermostat,  
you would  
press the  
keys in the  
shown  
I 2 0 0 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
Press once. Temperature digits  
c
disappear, show time set mode.  
AM  
PM  
:
HOUR  
I 2 0 0 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
sequence.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
Press and hold until current hour  
c
AM  
appears on display.  
HOUR  
MIN  
:
PM  
I 9 0 0 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
HEAT CcOOL  
Press and hold until current  
M T W TH F SA SU  
minutes appear on display.  
AM  
PM  
:
I 9 I 5 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
Press until current day appears  
HEAT CcOOL  
M T W TH F SA SU  
on display.  
AM  
DAY  
:
PM  
I 9 I 5 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
Returns to normal time and  
temperature.  
If return is not pressed it will return  
automatically in 10 seconds.  
HEAT CcOOL  
M T W TH F SA SU  
AM  
PM  
RETURN  
:
I 9 I 5 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
18-19  
Typical Suggested Summer  
and Winter Programs for Maximum Savings  
Studies conducted by the Department of  
Energy estimate that setting your thermostat  
MO  
to  
FR  
PROG #  
TIME  
5:00AM  
7:00AM  
3:00PM  
TEMP IN F° (C°)  
back 10°F for two 8-hour periods during  
winter can reduce your fuel bill by as much  
as 33%. By setting your thermostat up 5°  
for two 8-hour periods during summer you  
can reduce your fuel bill up to 25%.  
1
2
3
4
68 (20) 78 (25)  
60 (15) 85 (29)  
68 (20) 78 (25)  
10:00PM 62 (16) 82 (27)  
Your thermostat is capable of holding up to  
4 separate programs for each day of the  
week. You can program all weekdays,  
Monday to Friday, to the same 4 programs  
as shown in the table, or each weekday can  
have a different set of 4 programs. Similarly  
weekend programs, Saturday and Sunday,  
can be the same 4 programs or each  
weekend day can have a different set of 4  
programs.  
SA  
and  
SUN  
PROG #  
TIME  
TEMP IN F° (C°)  
1
2
3
4
5:00AM  
68 (20) 78 (25)  
10:00AM 62 (16) 82 (27)  
3:00PM 68 (20) 78 (25)  
10:00PM 62 (16) 82 (27)  
A typical set of programs is shown in Table 3.  
TABLE 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: The thermostat program will NOT  
take effect immediately after  
When your program becomes effective at  
the next time/temperature setting, the  
appropriate corresponding program number  
will appear on the display.  
programming of your thermostat but at  
the next programmed time/temperature  
change. The thermostat is preset to 68°F  
for heat and 78°F for air conditioning. So  
if you want a temperature other than 68°F  
or 78°F right away, use the temporary  
manual override feature (described on  
page 28) to enter your desired  
temperature setting.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
20-21  
Personal Program Schedule  
Before programming or changing the  
Use a pencil so you can revise your records  
program, use this Personal Program Schedule each time you change your temperature  
to determine which times and temperature  
settings will best satisfy both your comfort  
and energy saving requirements.  
settings.  
FOR WINTER  
FOR SUMMER  
PROGRAM PROGRAM PROGRAM PROGRAM  
PROGRAM PROGRAM PROGRAM PROGRAM  
NUMBER  
1
2
3
4
NUMBER  
1
2
3
4
MONDAY  
TIME  
TIME  
TIME  
TIME  
MONDAY  
TIME  
TIME  
TIME  
TIME  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TUESDAY  
TIME  
TIME  
TIME  
TIME  
TUESDAY  
TIME  
TIME  
TIME  
TIME  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
WEDNESDAY TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
WEDNESDAY TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
THURSDAY  
TIME  
TIME  
TIME  
TIME  
THURSDAY  
TIME  
TIME  
TIME  
TIME  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
FRIDAY  
TIME  
TIME  
TIME  
TIME  
FRIDAY  
TIME  
TIME  
TIME  
TIME  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
SATURDAY  
SUNDAY  
TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
SATURDAY  
SUNDAY  
TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
TIME  
TEMP  
TIME  
TIME  
TIME  
TIME  
TIME  
TIME  
TIME  
TIME  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
TEMP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming Your Thermostat  
Your thermostat can be programmed in two  
different ways.  
1. Auto-program method  
2. Manual method  
PROGRAM  
NUMBER  
TIME  
TEMP IN F° (C°)  
HEAT COOL  
1
2
3
4
5:00AM  
7:00AM  
3:00PM  
68 (20) 78 (25)  
60 (15) 85 (29)  
68 (20) 78 (25)  
MON. –  
FRI.  
Before programming, position the  
HEAT/OFF/COOL selector to the mode to be  
programmed.  
Auto-program method  
10:00PM 62 (16) 82 (27)  
5:00AM 68 (20) 78 (25)  
10:00PM 60 (15) 85 (29)  
3:00PM 68 (20) 78 (25)  
10:00PM 62 (16) 82 (27)  
In auto-program method, you can program  
your thermostat instantly for the entire week  
by simply pressing “Auto Prog.” key once.  
When this key is pressed, the standard  
program gets activated and your thermostat  
is programmed automatically. The standard  
program is shown in table 4.  
1
2
3
4
SAT. &  
SUN.  
TABLE 4  
Manual method  
In this method, each program is inserted  
according to your personal programming  
schedule.  
When the battery is first inserted, the  
thermostat is programmed for 68°F (20°C) in  
heat mode and 78°F (25°C) in cool mode.  
NOTE: There are no energy saving time or  
temperature settings.  
If you wish to change this program to suit  
your life style, you can do so by changing the  
time and the temperatures of those programs  
which you want to be different than standard  
programs. The method is explained in the  
manual method of programming.  
AUTO  
PROG  
Press  
. Your thermostat will be  
programmed automatically according to Table 4.  
Familiarize yourself with manual  
programming. The following example  
demonstrates the manual programming  
method. You can program or change the  
program of weekdays, weekends, or  
individual days.  
(If the slide switch is in the heat mode, only  
heat program is effective. In order to activate  
cool program, slide the switch to cool mode  
and press Auto Prog.”)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
22-23  
Programming Your Thermostat (Continued)  
NOTE: 1) The program time is set in  
increments of 15 minutes.  
3) When setting PM time, make  
sure the “PM” indicator  
appears on the display.  
2) The program temperature is  
set in increments of 1°F.  
Press  
Display Reads  
Weekday  
Programs  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
Normal display of time, temper-  
c
ature, and day of the week.  
AM  
PM  
:
8 9 1 5 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Step 1  
Step 2  
Step 3  
ݗ
ݚݙݘ
 
Selects days M to F for same set  
M T W TH F SA SU  
HEAT COOL  
c
of 4 programs each day.  
PROG  
AM  
PM  
:
DAY  
80 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
Program indicator (1) is displayed.  
68°F is displayed.  
0:00 space for time is displayed.  
M to F is displayed.  
M T W TH F SA SU  
HEAT COOL  
c
AM  
PM  
:
PROG  
80 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
Press and hold until 6:00 is  
displayed.  
Note AM/PM  
M T W TH F SA SU  
HEAT COOL  
c
AM  
PM  
:
HOUR  
86 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Press  
Display Reads  
Step 4  
ݗ
ݚݙݘ
 
HEAT COcOL  
M T W TH F SA SU  
Press once to change  
temperature to 69°F.  
Weekday program 1 is complete.  
Press PROG to move to  
program 2, 3, and 4 and follow  
the same steps  
AM  
:
PM  
86 00 69  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Use  
to insert or change time and  
HOUR  
MIN  
temperatures of other programs.  
Continue  
for  
Weekend  
Programs  
ݗ
ݚݙݘ
 
Selects weekend days SA, SU  
for same set of 2 programs each  
weekend day.  
Follow steps 2-4 to enter  
programs.  
M T W TH F SA SU  
HEAT COOL  
c
AM  
PM  
PROG  
DAY  
:
86 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Similar to weekday programming.  
to insert weekend programs.  
PROG  
HOUR  
MIN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
24-25  
Individual Day Programming  
To program for each individual day separately by a different set of programs, first select day  
by displaying the day of program, then insert the desired times and temperatures.  
Press  
Display Reads  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
M to F are selected. M to F will  
c
PROG  
DAY  
have same programs.  
AM  
PM  
:
80 00 68  
ݗ
ݚݙݘ
 
FILTER LO BAT  
SET TEMP HOLD TEMP  
HEAT COcOL  
M T W TH F SA SU  
SA and SU will have same  
PROG  
DAY  
program.  
AM  
PM  
:
83 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
M is selected, program for M  
c
PROG  
DAY  
only.  
AM  
PM  
:
80 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to enter programs  
for Monday.  
Use  
PROG  
HOUR  
MIN  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
T is selected.  
c
PROG  
DAY  
AM  
Similarly  
:
PM  
80 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
W is selected.  
c
PROG  
DAY  
AM  
PM  
:
80 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Display the day to be programmed and use  
to enter programs.  
PROG  
HOUR  
MIN  
NOTE: Another approach to programming is to first program all weekdays M through F  
and SA and SU as same programs. Then, display and change the programs of only  
those days which will have different programs.  
NOTE: If program time remains 0:00, that particular program will not be effective; e.g.,  
if Program #2 has time 0:00, the thermostat will jump from Program #1 to Program #3.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
26-27  
Reviewing Programs  
You may want to review the programs to see that the settings are compatible with your lifestyle.  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
Normal display of current time,  
Weekday  
Program  
c
temperature, and day of week.  
AM  
:
PM  
8 9 1 5 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
1st weekday program is displayed.  
Program indicator (1) appears.  
M to F indication appears.  
M T W TH F SA SU  
HEAT COOL  
c
AM  
PM  
:
PROG  
86 00 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Continue pressing  
to review programs.  
PROG  
NOTE: The temperatures you have  
entered will NOT take effect immediately,  
but at the next program time change. The  
Thermostat is pre-set to 68°F in heat  
mode and 78°F in cool mode.  
When your entered program becomes  
effective, the corresponding program  
number will appear on the display.  
After programming, confirm  
PROG  
the new programs by pressing  
If you want a temperature other than 68°F  
or 78°F right away, you must use the  
manual override feature described below  
to enter the temperature you want.  
If you are armchair programming the  
thermostat, before you mount the face of the  
thermostat, turn the system selector to the  
OFF position.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Review The Current Temperature Setting:  
ݗ
ݘ
ݚݙ
 
Current time and temperature  
M T W TH F SA SU  
HEAT COOL  
c
AM  
:
PM  
8 9 1 5 6 8  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݘ
ݚݙ
 
70 indicates the current setting of  
the thermostat is 70°F. 68 shows  
the present room temperature as  
68°F.  
M T W TH F SA SU  
HEAT COOL  
Press  
for 2  
seconds  
or less:  
c
AM  
PM  
:
86 70 68  
FILTER LO BAT  
SET TEMP HOLD TEMP  
or  
If held for more than 2 seconds,  
you will manually override your  
present temperature to a new  
setting as explained below.  
Manual Override of Program  
If You Want to Change the Temperature Without Affecting  
Your Program:  
Press and hold  
Press and hold  
to raise  
to lower  
temperature.  
temperature.  
The new temperature will hold until the next program time is reached.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
28-29  
Temporary Manual Override  
In the following example, the present room temperature is 60°F and we want to raise the  
temperature to 70°F temporarily until the next program.  
ݗ
ݘ
ݚݙ
 
Press arrow to display current  
M T W TH F SA SU  
HEAT COOL  
c
set and room temperatures.  
AM  
PM  
:
8 9 6 8 6 0  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
Continue pressing arrow. After 2  
seconds, the set temperature  
digits will blink and begin to  
increase until the button is  
released at the desired setting (in  
this case 70°F).  
c
AM  
PM  
:
8 9 7 0 6 0  
FILTER LO BAT  
SET TEMP HOLD TEMP  
Program number flashes.  
Press return or in 10 seconds it  
will return to showing current  
time and temperature.  
To display a manual override setting, press  
either arrow for less than 2 seconds.  
When arrow is released, the display will  
show current time and temperature.  
Your thermostat is now in manual override  
mode to 70°F until the next program.  
Indicator number flashes until the next  
program time comes into effect.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming Your Thermostat (Continued)  
Permanent Manual Override  
In the event you wish to hold your manual  
override for vacation or just an extended  
period of time, follow the temporary manual  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
override instructions on  
page 28, then immediately  
press HOLD/CLEAR.  
c
HOLD  
CLEAR  
HOLD  
CLEAR  
AM  
:
PM  
8 9 5 5 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
This will maintain override  
setting indefinitely. HOLD” will  
appear on the display.  
To Return To Program*  
ݗ
ݘ
ݚݙ
 
To return immediately to the  
HEAT CcOOL  
M T W TH F SA SU  
current program, press  
HOLD  
CLEAR  
HOLD  
CLEAR  
AM  
PM  
:
8 9 1 5 5 5  
HOLD/CLEAR until program  
number appears. “HOLD”  
will disappear if you were in  
permanent manual override.  
FILTER LO BAT  
SET TEMP HOLD TEMP  
(*From temporary or permanent manual  
override state)  
NOTE: You can also return the current  
program by pressing HOLD TEMP” once  
in permanent override mode.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Other Features  
30-31  
Temperature Span  
Your thermostat is pre-programmed at the  
factory to cycle when the temperature rises  
1° above or 1° below the temperature  
setting. It cannot be changed.  
Backlighting (Model 44350 only)  
Press  
The display will remain backlit for  
LIGHT  
approximately five (5) seconds. If another  
button is pushed, the five second timer will  
reset, and the light will turn off five seconds  
after the last button is pressed.  
Your thermostat comes with an electrolumi-  
nescent lamp for easy viewing of the display  
in the dark. To activate press the “light”  
button between the up and down arrow keys.  
12/24 Hour Clock  
The 12/24 hour switch is located on the  
printed circuit board inside the thermostat.  
(Model 44350 only) Pressing the 12/24  
button alternates the clock between 12 or  
24 hour (military) mode.  
NOTE: Move system selector slide switch  
to “OFF” before removing thermostat  
from wall and changing 12/24 hour clock  
mode.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operations  
Using the Filter Review Feature  
Your thermostat also keeps a record of the  
number of hours your filter has been in use.  
To maximize energy efficienty, change or  
clean your filter regularly.  
To help you remember, at 500 hours, the  
word “FILTER” will appear on the display,  
reminding you to change the filter and reset  
the counter back to zero. The “FILTER” will  
continue to display if the counter is not set  
back to zero.  
Filter review will display up to 999 hours  
and 59 minutes of usage. Counter will start  
from zero after 999 hours and 59 minutes  
of usage.  
ݗ
ݚݙݘ
 
Indicates the usage of filter or total  
Press for  
2 Seconds  
or Less  
M T W TH F SA SU  
HEAT COOL  
c
usage in hours and minutes. For  
example, 145 hours and 38 minutes.  
(If held for more than 2 seconds, the  
counter will reset to zero.)  
AM  
FILTER  
:
PM  
8 I 4 5 3 8  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
HEAT CcOOL  
M T W TH F SA SU  
Back to normal display of time and  
temperature.  
Auto-return after 10 seconds if no  
AM  
PM  
RETURN  
FILTER  
:
8 9 I 5 7 2  
FILTER LO BAT  
SET TEMP HOLD TEMP  
key is pressed.  
To reset filter  
counter back  
to zero.  
Press and  
Hold for  
3 to 4  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
Indicates the usage of filter or total  
c
usage in hours.  
AM  
PM  
:
8 I 4 5 3 8  
FILTER LO BAT  
SET TEMP HOLD TEMP  
ݗ
ݚݙݘ
 
M T W TH F SA SU  
HEAT COOL  
The counter will reset to zero.  
When released, returns to current  
time and temperature.  
c
AM  
PM  
:
8 0 00 00  
Seconds  
FILTER LO BAT  
SET TEMP HOLD TEMP  
NOTE: Press FILTER RESET to clear the filter counter on Model 44300. The counter is  
only reset when FILTER” is displayed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Problem  
32-33  
Solution  
SCRAMBLED OR DOUBLE DISPLAY  
(numbers over numbers  
1. Remove clear mylar sticker.  
NO DISPLAY  
1. Check battery connections and batteries.  
2. Press reset button once with a small pin  
and hold in for two seconds.  
ENTIRE DISPLAY DIMS  
1. Replace batteries.  
PROGRAM DOES NOT CHANGE AT YOUR  
DESIRED SETTING  
1. Check that time is set properly to “AM” or  
PM.”  
2. Check that thermostat is not in "HOLD"  
mode.  
3. Check for correct day setting.  
AUTO/FAN DOES NOT COME ON  
1. Move HG/HE system selector to opposite  
position.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HEATING OR COOLING DOES NOT GO  
ON OR OFF  
1. Check that function switch is in correct  
position (“HEAT” or “COOL”).  
2. There may be as much as 20 seconds  
delay before the system turns on - wait  
and check.  
3. Check your circuit breakers and switches  
to ensure there is power to the system.  
4. Replace batteries.  
5. Make sure your furnace blower door is  
closed properly.  
6. If your system only uses 4-wires, be sure  
the jumper wire is installed between the  
RC and RH terminals.  
ERRATIC DISPLAY  
1. Press the reset button once with a small  
pin and hold in for two seconds. Then  
reprogram.  
IF UNIT CONTINUES TO OPERATE IN OFF  
POSITION  
1. Replace unit.  
1. Replace unit.  
THERMOSTAT READS , HI, LO  
PERMANENTLY  
If you experience any other problems, call 901-745-9222 from 8AM to 5PM Central  
Standard time for technical assistance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring Diagrams  
34-35  
4-wire Heat/Cool System  
THERMOSTAT  
Jumper  
RC  
RH  
G
W
Y
Heat/Cool  
Transformer  
Fan  
Heat Relay  
or Valve  
Cool  
Contactor  
Relay  
5-wire Heat/Cool System  
THERMOSTAT  
RC  
RH  
G
W
Y
Cool  
Heat  
Fan  
Heat Relay  
or Valve  
Cool  
Transformer  
Transformer  
Relay  
Contactor  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-wire Heat Only  
3-wire Heat Only  
3-wire Cool Only  
THERMOSTAT  
RC  
RC  
RC  
RH  
G
W
Y
Y
Y
Heat  
Heat Relay  
or Valve  
Transformer  
THERMOSTAT  
RH  
G
W
Heat  
Fan  
Heat Relay  
or Valve  
Transformer  
Relay  
THERMOSTAT  
RH  
G
W
Cool  
Transformer  
Fan  
Cool  
Contactor  
Relay  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Dust Collector G1028Z G1029Z User Manual
Grizzly Grinder H4379 User Manual
Hamilton Beach Electric Steamer 37536 User Manual
Hamilton Beach Kitchen Grill 840058500 User Manual
Hans Grohe Plumbing Product 41534XX1 User Manual
Harbor Freight Tools Nail Gun 98733 User Manual
HP Hewlett Packard Carpet Cleaner 608349 User Manual
Husky Paint Sprayer HDS550 User Manual
Husqvarna Brush Cutter 525RK User Manual
IBM Grinder 42T7905 User Manual