Hoshizaki Ice Maker SRC 10H User Manual

Hoshizaki America, Inc.  
Hoshizaki  
Modular Flaker  
Serenity Series  
Model  
FS-1001MLH/-C  
Including  
Condensing Unit Model SRC-10H  
INSTRUCTION MANUAL  
“A Superior Degree  
of Reliability”  
Issued: 7-29-2005  
Revised: 12-27-2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• Please review this manual. It should be read carefully before the icemaker is installed  
and operated. Only qualified service technicians should install, service and maintain the  
icemaker. This manual should be made available to the technician prior to installation,  
maintenance or service.  
• Keep this manual with the icemaker for later reference.  
CONTENTS  
I. Specifications .................................................................................................................... 4  
1. Nameplate Rating ........................................................................................................ 4  
[a] FS-1001MLH, FS-1001MLH-C.............................................................................. 4  
[b] Condensing Unit Model SRC-10H ........................................................................ 5  
2. Dimensions/Connections ............................................................................................. 6  
[a] FS-1001MLH, FS-1001MLH-C.............................................................................. 6  
[b] With Storage Bin.................................................................................................... 7  
[c] Condensing Unit Model SRC-10H ........................................................................ 8  
II. Installation and Operating Instructions .............................................................................. 9  
1. Checks Before Installation............................................................................................ 9  
2. How to Remove Panels ................................................................................................ 9  
3. Location...................................................................................................................... 10  
4. Setup .......................................................................................................................... 10  
5. Electrical Connection ................................................................................................. 11  
6. Installation of Remote Condensing Unit ..................................................................... 11  
[a] Checks Before Installation................................................................................... 11  
[b] Location............................................................................................................... 11  
[c] Setup ................................................................................................................... 12  
[d] Electrical Connection .......................................................................................... 13  
7. Water Supply and Drain Connections......................................................................... 14  
8.Timer Setting .............................................................................................................. 15  
9. Final Checklist............................................................................................................ 16  
10. Startup...................................................................................................................... 17  
11. Preparing the Icemaker for Long Storage ................................................................. 18  
III. Cleaning and Maintenance ............................................................................................ 19  
1. Cleaning and Sanitizing Instructions .......................................................................... 19  
[a] Cleaning Solution................................................................................................ 19  
[b] Cleaning Procedure ............................................................................................ 20  
[c] Sanitizing Solution............................................................................................... 21  
[d] Sanitizing Procedure - Initial................................................................................ 21  
[e] Sanitizing Procedure - Final ................................................................................ 22  
2. Maintenance Instructions............................................................................................ 24  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
I. Specifications  
1. Nameplate Rating  
[a] FS-1001MLH, FS-1001MLH-C  
HOSHIZAKI ICE MAKER  
MODEL NUMBER  
SERIAL NUMBER  
FS-1001MLH  
AC SUPPLY VOLTAGE  
115-120/60/1  
COMPRESSOR  
GEAR MOTOR  
--- --- ---  
120V 3.0FLA 1/4HP  
FAN MOTOR  
--- --- ---  
OTHER  
120V  
0.53A  
15 AMPS  
15 AMPS  
15 AMPS  
15 AMPS  
MAXIMUM FUSE SIZE  
MAX. HACR BREAKER(USA ONLY)  
MAX. CIRC BREAKER (CANADA ONLY)  
MINIMUM CIRCUIT AMPACITY  
DESIGN PRESSURE  
HI-427PSI LO-230PSI  
REFRIGERANT  
404A  
See the nameplate for electrical and refrigeration  
specifications. This nameplate is located on the  
left-hand side of the rear panel.  
IMPORTANT  
This icemaker is designed for connection to HOSHIZAKI CONDENSING  
UNIT, Model SRC-10H only! CONNECTION TO ANOTHER CONDENSING  
UNIT WILL VOID WARRANTY.  
We reserve the right to make changes in specifications and design without prior notice.  
NOTE: Only the “MODEL NUMBER” is replaced for FS-1001MLH-C.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
[b] Condensing Unit Model SRC-10H  
MODEL NUMBER  
SERIAL NUMBER  
SRC-10H  
AC SUPPLY VOLTAGE  
208-230/60/1 (3 WIRE W/  
NEUTRAL FOR 115V)  
208-230V 6.5RLA 46LRA  
COMPRESSOR  
FAN MOTOR  
OTHER  
115V 1.3FLA 65W  
120V  
0.2A  
20 AMPS  
20 AMPS  
20 AMPS  
20 AMPS  
MAXIMUM FUSE SIZE  
MAX. HACR BREAKER(USA ONLY)  
MAX. CIRC BREAKER (CANADA ONLY)  
MINIMUM CIRCUIT AMPACITY  
DESIGN PRESSURE  
HI-427PSI LO-230PSI  
REFRIGERANT  
404A 8lb 2oz.  
See the nameplate for electrical and refrigeration  
specifications. This nameplate is located on the  
left-hand side of the right-side panel.  
We reserve the right to make changes in specifications and design without prior notice.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Dimensions/Connections  
Unit = inches [mm]  
[a] FS-1001MLH, FS-1001MLH-C  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
[b] With Storage Bin  
Unit = inches [mm.]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[c] Condensing Unit Model SRC-10H  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. Installation and Operating Instructions  
1. Checks Before Installation  
WARNING  
Remove shipping carton, tape(s) and packing. If packing material is left in  
the icemaker, it will not work properly.  
IMPORTANT  
Ensure all components, fasteners and thumbscrews are securely in place.  
1) Remove all panels to prevent damage when installing the icemaker. (See “2. How to  
Remove Panels.”)  
2) Remove the package containing the accessories from inside the icemaker.  
3) Remove the protective plastic film from the panels. If the icemaker has been exposed  
to the sun or to heat, remove the film after the icemaker cools.  
4) Check that the refrigerant lines do not rub or touch lines or other surfaces.  
5) See the nameplate on the rear panel, and check that your supplied voltage  
corresponds with the voltage specified on the nameplate.  
6) This icemaker requires a storage bin. The recommended storage bin is HOSHIZAKI  
ICE STORAGE BIN, Model B-500 series.  
7) This icemaker is designed for connection to HOSHIZAKI CONDENSING UNIT,  
Model SRC-10H only!  
NOTE: CONNECTION TO ANOTHER CONDENSING UNIT WILL VOID  
WARRANTY.  
2. How to Remove Panels  
See Fig. 1  
a) Front/Rear Panel ..... Remove the screw(s).  
Lift up and pull towards yo
b) Top Panel................ Lift up.  
c) Side Panel............... Remove the thumbscrew.  
Pull up and lift off.  
Fig. 1  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Location  
WARNING  
This icemaker is not intended for outdoor use. Normal operating ambient  
temperature should be within +45°F to +100°F; Normal operating water  
temperature should be within +45°F to +90°F. Operation of the icemaker for  
extended periods outside of these normal temperature ranges may affect  
production capacity.  
For best operating results:  
• Icemaker should not be located next to ovens, grills or other high heat producing  
equipment.  
• Location should provide a firm and level foundation for the equipment.  
• Allow 6" clearance at rear and sides for proper air circulation and ease of maintenance  
and /or service should they be required. Allow 24" clearance at top to allow for  
removal of the auger.  
4. Setup  
1) Unpack the storage bin, and attach the four adjustable legs provided (bin accessory)  
to the bottom of the storage bin.  
2) Position the storage bin in the selected permanent position.  
3) Place the icemaker on the top of the storage bin.  
4) Secure the icemaker to the storage bin by using  
the two braces, four bolts, and four self-tapping screw
provided. The four bolts come attached to the icemak
Use the four self-tapping screws to make the appropr
holes in the storage bin. See Fig. 2.  
5) Insure a proper seal between the icemaker and the  
storage bin.  
6) Level the icemaker/storage bin in both the  
left-to-right and front-to-rear directions. Adjust  
the storage bin legs to level the icemaker.  
Fig. 2  
7) Replace the icemaker's panels. Secure the front panel and rear panel  
with the proper screw(s) and each side panel with the proper thumbscrew.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Electrical Connection  
This icemaker must have an independent power supply or receptacle of proper capacity.  
See the nameplate.  
6. Installation of Remote Condensing Unit  
[a] Checks Before Installation  
1) Unpack and remove shipping carton, tape(s) and packing.  
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan  
blade turns freely.  
3) Make sure that the icemaker, line sets and remote condensing unit all use R-404A  
refrigerant.  
[b] Location  
The condensing unit must be positioned in a permanent site under the following  
guidelines.  
• A firm and flat site.  
• A dry and well ventilated area with 24" clearance on both front and rear for ease of  
maintenance and service should they be required.  
• Normal condenser ambient temperature: -4°F to +122°F. Temperatures not within this  
operating range may affect the production capacity of the icemaker.  
• The maximum line length is 55 feet. Vertical distance between the condensing unit and  
icemaker should not exceed 30 feet above or 10 feet below the icemaker.  
Note: If the recommended inemaker  
performance may be reduced.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[c] Setup  
1) Secure the legs to the condensing unit with eight M8 x 16 mm hexagon bolts and M8 nuts  
as shown in the illustration. See Fig. 4.  
Note: Locate the legs symmetrically.  
2) The legs have eight mounting holes. Secure the legs with eight bolts (not included).  
3) Install line sets. Precharged tubing kits, available as optional equipment from  
HOSHIZAKI AMERICA, are recommended.  
To fabricate line sets:  
a. Install enough length of two copper tubings between the icemaker and the condensing  
unit. See Fig. 5.  
• The maximum line length is 55 feet.  
• Vertical distance between the condensing unit and icemaker should not exceed 30  
feet above or 10 feet below the icemaker.  
• If the vertical distance between the condensing unit and icemaker is greater than 18  
feet, a p-trap (5/8" OD tubing) must be installed in the suction line. The p-trap must  
be within 18 vertical feet of both the condensing unit and the icemaker. This will  
ensure sufficient oil return to the compressor.  
b. Insulate the two copper tubings separately.  
c. Install Parker quick connect couplings on each end.  
Fig. 4  
4) Line sets fabricated in the field should be evacuated through the charging ports on the  
Parker quick connect couplings and charged with R-404A refrigerant vapor to a pressure  
of15-30 PSIG.  
Note: Factory fabricated tubing kits are precharged and do not need to be evacuated.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5) Remove the plastic caps protecting the couplings. Apply two drops of POE oil to the male  
threads of the couplings. Attach the two refrigerant lines to the male couplings on the  
icemaker and the remote condensing unit. The couplings must be tightened 1/4 turn  
beyond fully seated. Each refrigerant line must be connected as follows:  
Icemaker suction refrigerant line - 5/8" OD tubing  
Icemaker liquid refrigerant line - 1/4" OD tubing  
Note: Make the connections at the remote condensing unit first and then at the icemaker.  
[d] Electrical Connection  
WARNING  
1. This condensing unit must have a separate power supply. See the  
nameplate.  
2. This condensing unit requires a ground that meets the national and local  
electrical code requirements. To prevent possible electrical shock to  
individuals or extensive damage to equipment, install a proper ground wire to  
this condensing unit.  
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.  
• Usually an electrical permit and services of a licensed electrician are required.  
• Installation of an external power disconnect may be required by local code.  
1) Remove the louver panel.  
2) Remove the control box cover.  
3) Connect the three loose leads in the control box to the power supply.  
Note: The white lead must be attached to the neutral line.  
4) Replace the control box cover and the louver panel in their correct positions.  
Note: The icemaker and condensing unit have independent power supply circuits.  
Fig. 6  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Water Supply and Drain Connections  
See Fig. 7  
• External filters or strainers may be required depending on the water quality.  
• Water supply inlet is 1/2" female pipe thread (FPT).  
• A water supply line shut-off valve and drain valve should be installed. A minimum of 3/8"  
OD copper tubing is recommended for the water supply lines.  
• Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If  
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.  
• Drain outlet for icemaking is 3/4" FPT. The icemaker drain piping connections must be  
made separately from the bin drain piping connections.  
• A vented tee connection is required for proper flow.  
• The drains must have 1/4" fall per foot on horizontal runs to get a good flow.  
• The drains should not be piped directly to the sewer system. An air gap of a minimum of  
2 vertical inches should be between the end of the drain pipe from the icemaker or the ice  
bin and the floor drain.  
• A plumbing permit and services of a licensed plumber may be required in some areas.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Timer Setting  
See Fig. 8  
The ice machine is equipped with an adjustable timer in the control box. It controls the  
amount of time the machine waits before shutting down after ice is detected by the bin  
control; the timer thereby controls the ice level in the bin or dispenser. The timer is factory  
set to the minimum delay of 10 seconds.  
Observe the following guidelines when selecting a timer setting.  
• When installed on a Hoshizaki bin, any timer setting is acceptable. Increasing the timer  
setting will allow a higher level of ice in the bin before the ice machine shuts down.  
• When installed on a Lancer dispenser designed for cubelet ice, the timer setting must  
remain at 10 seconds.  
• For other dispenser applications, the ice level at shutoff may need to be adjusted  
depending on the dispenser agitation or dispense method. Observe the ice level in the bin  
after the unit cycles off with the 10 second setting and adjust as necessary for the proper  
fill level.  
10  
1000  
Timer Setting Control  
Fig. 8  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Final Checklist  
1) Is the icemaker level?  
2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F and the  
water temperature within +45°F to +90°F all year around?  
3) Is there at least 6" clearance at rear and sides and 24" at top for maintenance or service?  
4) Have all shipping carton, tape(s) and packing been removed from the icemaker?  
5) Are all components, fasteners and thumbscrews securely in place?  
6) Have all electrical and piping connections been made?  
7) Has the power supply voltage been checked or tested against the nameplate rating?  
8) Are the water supply line shut-off valve and drain valve installed? Has the water supply  
pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG?  
Note: The icemaker stops running when the water supply is OFF or when the pressure is  
below 10 PSIG. When the proper water pressure is restored, the icemaker  
automatically starts running again.  
9) Have the compressor hold down bolts and the refrigerant lines been checked against  
vibration and possible failure?  
10) Has the bin control switch been checked for correct operation? To check, use an object  
to cover the chute opening on the bottom of the icemaker. The pump down solenoid  
should de-energize within 90 seconds.  
11) Has the secondary bin control been checked for correct operation? Move the actuator  
located in the top of the chute. The gear motor should stop in 6 seconds.  
12) Has the end user been given the instruction manual, and instructed on how to operate  
the icemaker and the importance of the recommended periodic maintenance?  
13) Has the end user been given the name and telephone number of an authorized service  
agent?  
14) Has the warranty tag been filled out and forwarded to the factory for warranty  
registration?  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Startup  
IMPORTANT  
1. The condensing unit is shipped with the contacts of the secondary low  
pressure switch open. Once power is supplied to the condensing unit, wait at  
least 4 hours before starting the unit. This will allow the system to settle and  
refrigerant to evaporate from oil in the compressor. To start the unit, press the  
manual reset button on the secondary low pressure switch. Doing this will  
prevent damage to the compressor.  
2. If the unit is turned off, wait for at least 3 minutes before restarting the  
icemaker to prevent damage to the evaporator.  
3. In the event of a power failure that is less than 3 minutes in duration, the gear  
motor fuse in the ice machine could blow upon restart. If this occurs, turn off  
the machine, replace the fuse and wait at least 3 minutes before restarting.  
1) Clean the storage bin. (See “III. 2. Maintenance Instructions.”)  
2) Open the water supply line shut-off valve.  
3) Move the flush switch on the control box to the “ICE” position.  
4) Turn on the power switch on the control box.  
5) Replace all exterior panels in their correct positions.  
6) Turn on the power supply.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. Preparing the Icemaker for Long Storage  
See Fig. 9  
WARNING  
When shutting off the icemaker for an extended time, drain out all water from the  
water line and remove the ice from the storage bin. The storage bin should be  
cleaned and dried. Drain the icemaker to prevent damage to the water supply  
line at sub-freezing temperatures, using air or carbon dioxide. Shut off the  
icemaker until the proper ambient temperature is resumed.  
1) Run the icemaker with the water supply line shut-off valve closed.  
2) Open the drain valve and blow out the water inlet line by using air pressure.  
3) Turn off the power supply.  
4) Remove the front panel.  
5) Move the flush switch on the control box to the “FLUSH” position.  
6) Turn on the power supply, and then drain out all water from the water line.  
7) Turn off the power supply.  
8) Turn off the power switch on the control box.  
9) Replace the front panel in its correct position.  
10) Close the drain valve.  
11) Remove all ice from the storage bin, and cle
Fig. 9  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. Cleaning and Maintenance  
IMPORTANT  
Ensure all components, fasteners and thumbscrews are securely in place after  
any maintenance or cleaning is done to the equipment.  
1. Cleaning and Sanitizing Instructions  
WARNING  
1. HOSHIZAKI recommends cleaning this unit at least once a year. More  
frequent cleaning, however, may be required in some existing water  
conditions.  
2. To prevent injury to individuals and damage to the icemaker, do not use  
ammonia type cleaners.  
3. Always wear liquid-proof gloves to prevent the cleaning and sanitizing  
solutions from coming into contact with skin.  
[a] Cleaning Solution  
Dilute 4.8 fl. oz. (142 ml) of recommended cleaner Hoshizaki “Scale Away” or  
“LIME-A-WAY” (Economics Laboratory, Inc.) with 0.8 gallons (3 l) of warm water. This is a  
minimum amount. Make more solution if necessary.  
IMPORTANT  
For safety and maximum effectiveness, use the solution immediately after  
dilution.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[b] Cleaning Procedure  
The cleaning process will remove lime deposits from the water system.  
1) Remove the front panel and top panel, then turn off the power supply.  
2) Close the water supply line shut-off valve.  
3) Remove all ice from the storage bin.  
4) Move the flush switch to the “FLUSH” position.  
5) Turn on the power supply and drain out all water from the water line.  
6) Turn off the power supply.  
7) Remove the control water valve by removing the fitting nut and two mounting screws. Do  
not lose the packing.  
8) Check the control water valve screen for debris and clean as necessary.  
9) Replace the control water valve in its correct position.  
10) Remove the strap connecting the spout to the chute assembly.  
11) Remove the thumbscrews securing the spout and lift it off.  
12) Pour the cleaning solution over the extruding head until the evaporator assembly and  
the reservoir are filled and the solution starts to overflow into the drain pan.  
Note: If there is excess scale on the extruding head, fill the evaporator assembly and  
reservoir as described above, then use a clamp on the reservoir hose between the  
reservoir and evaporator assembly to block flow. Pour additional cleaning fluid  
over the extruding head until the evaporator assembly is completely full.  
13) Replace the spout and strap in their correct positions.  
14) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on  
the reservoir hose in step 9, remove it before operation.  
15) Move the flush switch to the “ICE” position, then turn on the power supply. Replace the  
top panel and front panel in their correct positions. Make ice using the solution until the  
icemaker stops making ice.  
Note: Always discard the contaminated ice produced during this procedure.  
16) Remove the front panel.  
17) Move the flush switch to the “FLUSH” position to drain the remainder of the solution.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18) After the solution is drained, move the flush switch to the “ICE” position.  
19) Replace the front panel in its correct position.  
20) Open the water supply line shut-off valve and supply water to the reservoir.  
21) When the gear motor starts, remove the front panel and turn off the power supply.  
22) Drain out all water from the water line. See 4) through 6).  
[c] Sanitizing Solution  
Dilute 2.5 fl. oz. (74 ml or 5 tbs) of IMS-II Sanitizer or a 5.25% sodium hypochlorite solution  
(chlorine bleach) with 5 gallons (19 l) of warm water.  
IMPORTANT  
For safety and maximum effectiveness, use the solution immediately after  
dilution.  
[d] Sanitizing Procedure - Initial  
The sanitizing process will sanitize the icemaker.  
1) Close the water supply line shut-off valve.  
2) Remove the strap connecting the spout to the chute assembly.  
3) Remove the thumbscrews securing the spout and lift it off. Remove the rubber O-ring and  
nylon O-ring at the top of the cylinder and also remove the packing between the spout  
and the chute.  
4) Pour the sanitizing solution over the extruding head until the evaporator assembly and  
the reservoir are filled and the solution starts to overflow into the drain pan.  
5) Remove the two thumbscrews securing the proximity switch to the chute assembly.  
6) Remove the chute assembly from the icemaker.  
7) Remove the packing at the bottom of the ice chute.  
8) Remove the three ties and the chute insulation.  
9) Remove the six wing nuts and two baffles.  
10) Remove the two thumbscrews, the plate and the packing from the top of the ice chute,  
then remove the bin control assembly by sliding it slightly toward the chute opening and  
lifting it off.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11) Disassemble the bin control assembly by removing the two snap pins, shaft and  
actuator.  
12) Soak the removed parts in .25 gallons (1 l) of sanitizing solution for 10 minutes then  
wipe them down.  
13) Rinse the parts thoroughly.  
IMPORTANT  
If the solution is left on these parts, they will rust.  
14) Replace all parts in their correct positions.  
IMPORTANT  
When installing the baffles, make sure that the bent surface (the one without the  
studs) faces the actuator so that the bent surface can guide the ice to the center  
of the actuator.  
15) Move the flush switch to the “ICE” position, then turn on the power supply. Replace the  
top panel and front panel in their correct positions. Make ice using the solution until the  
icemaker stops making ice.  
Note: Always discard the contaminated ice produced during this procedure.  
[e] Sanitizing Procedure - Final  
1) Remove the front panel and top panel, then turn off the power supply.  
2) Move the flush switch to the “FLUSH” position.  
3) Turn on the power supply and drain out all water from the water line.  
4) Turn off the power supply.  
5) Remove the strap connecting the spout to the chute assembly.  
6) Remove the thumbscrews securing the spout and lift it off.  
7) Pour the sanitizing solution over the extruding head until the evaporator assembly and  
the reservoir are filled and the solution starts to overflow into the drain pan.  
8) Replace the spout and strap in their correct positions.  
9) Allow the icemaker to sit for about 10 minutes before operation.  
10) Move the flush switch to the “ICE” position, then turn on the power supply. Replace the  
top panel and front panel in their correct positions. Make ice using the solution until the  
icemaker stops making ice.  
Note: Always discard the contaminated ice produced during this procedure.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11) Remove the front panel.  
12) Move the flush switch to the “FLUSH” position to drain the remainder of the solution.  
13) After the solution is drained, move the flush switch to the “ICE” position.  
14) Replace the front panel in its correct position.  
15) Open the water supply line shut-off valve and supply water to the reservoir.  
16) When the gear motor starts, remove the front panel and turn off the power supply.  
17) Drain out all water from the water line. See 2) and 3).  
18) Move the flush switch to the “ICE” position and run the icemaker.  
19) Turn off the power supply after 30 minutes.  
20) Pour warm water into the storage bin to melt all ice, and then clean the bin liner with the  
solution.  
21) Flush out any solution from the storage bin.  
22) Turn on the power supply and start the automatic icemaking process.  
IMPORTANT  
1. After cleaning, do not use ice made from the sanitizing solution. Be careful  
not to leave any solution in the storage bin.  
2. Follow carefully any instructions provided with the bottles of cleaning or  
sanitizing solution.  
3. Never run the icemaker when the reservoir is empty.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Maintenance Instructions  
IMPORTANT  
1. This icemaker must be maintained individually, referring to the instruction  
manual and labels provided with the icemaker.  
2. To achieve optimum icemaker performance, the following parts need periodic  
inspection and maintenance:  
Extruding Head and Upper Bearing  
Housing and Lower Bearing  
Evaporator Cylinder  
Auger  
GearMotor  
Mechanical Seal  
These parts should be inspected at least once a year or every 10,000  
hours of operation. Their service life, however, depends on water quality  
and environment. More frequent inspection and maintenance are  
recommended in bad or severe water conditions.  
Replacement of the following consumable parts is recommended if wear  
exceeds factory recommendations:  
Upper Bearing  
Lower Bearing  
Mechanical Seal  
Consult with your local distributor about inspection and maintenance service.  
To obtain the name and phone number of your local distributor, call  
Hoshizaki Technical Support at 1-800-233-1940 in the USA.  
1) Stainless Steel Exterior  
To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a  
damp cloth containing a neutral cleaner to wipe off oil or dirt build up.  
2) Storage Bin and Scoop  
• Wash your hands before removing ice. Use the plastic scoop provided (bin  
accessory).  
• The storage bin is for ice use only. Do not store anything else in the bin.  
• Keep the scoop clean. Clean using a neutral cleaner and rinse thoroughly.  
• Clean the bin liner using a neutral cleaner. Rinse thoroughly after cleaning.  
3) Condenser  
Check the condenser once a year and clean the coil if required by using a brush or  
vacuum cleaner. More frequent cleaning may be required depending on the location of  
the condensing unit.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOSHIZAKI AMERICA, INC.  
618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A2PB10B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco GPS Receiver 78 User Manual
Graco Swing Sets ISPS013AC User Manual
Grundig Flat Panel Television 32 VLC 6110 C User Manual
GSW Water Heater 319594 000 User Manual
Hamilton Watch Watch Multi Touch Watch User Manual
HannsG Computer Monitor HQ191DP User Manual
Honeywell Air Cleaner F111 Series 1 User Manual
Hotpoint Washer AQ1131 User Manual
HP Hewlett Packard Portable Media Storage MSL6000 User Manual
IDEAL INDUSTRIES Camera Accessories 61 686 User Manual