		 Hoshizaki America, Inc.   
					Hoshizaki   
					Self-Contained Flaker   
					Model   
					F-330BAH(-C)   
					INSTRUCTION MANUAL   
					“A Superior Degree   
					of Reliability”   
					
					® 
					Issued: 5-4-2007   
					Revised: 9-5-2007   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				• Please review this manual. It should be read carefully before the icemaker is installed   
					and operated. Only qualified service technicians should install, service, and maintain the   
					icemaker. This manual should be made available to the technician prior to installation,   
					maintenance, or service.   
					• Keep this manual with the icemaker for later reference.   
					CONTENTS   
					
					A. Nameplate Rating......................................................................................................... 4   
					B. Dimensions/Connections.............................................................................................. 5   
					
					A. Checks Before Installation............................................................................................ 6   
					B. How to Remove Panels ............................................................................................... 6   
					C. Location........................................................................................................................ 7   
					
					E. Electrical Connection.................................................................................................... 7   
					F. Water Supply and Drain Connections........................................................................... 7   
					
					H. Startup........................................................................................................................ 10   
					
					
					
					
					
					
					
					B. Maintenance .............................................................................................................. 15   
					C. Preparing the Icemaker for Long Storage ................................................................. 16   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				I. Specifications   
					A. Nameplate Rating   
					1. F-330BAH, F-330BAH-C   
					MODEL NUMBER   
					SERIAL NUMBER   
					AC SUPPLY VOLTAGE   
					AMPERES   
					F-330BAH   
					115/60/1   
					6.7 AMPS   
					DESIGN PRESSURE   
					REFRIGERANT   
					HI-470PSI LO-230PSI   
					404A 7.1 OZ.   
					MOTOR-COMPRESSOR THERMALLY PROTECTED,   
					NOT INTENDED FOR OUTDOOR USE!   
					Hoshizaki America, Inc.   
					Peachtree City, GA   
					
					LISTED   
					ICE MAKER   
					946Z   
					Note: Only the "MODEL NUMBER" is replaced for F-330BAH-C.   
					See the nameplate for electrical and refrigeration specifications. This nameplate is located   
					on the rear panel.   
					We reserve the right to make changes in specifications and design without prior notice.   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				II. Installation and Operating Instructions   
					A. Checks Before Installation   
					IMPORTANT   
					1. Install in accordance with all applicable national, state, and local regulations.   
					ꢀ. Remove shipping carton, tape, and packing. If any are left in the icemaker, it   
					will not work properly.   
					3. Ensure all components, fasteners, and thumbscrews are securely in place   
					after installation.   
					• 
					Remove the top panel and front panel to prevent damage when installing the   
					icemaker.   
					• 
					• 
					Remove the package containing the accessories.   
					Remove the protective plastic film from the panels. If the icemaker is exposed   
					to the sun or to heat, remove the film after the icemaker cools.   
					• 
					Check that the refrigerant lines do not rub or touch lines or other surfaces, and   
					that the fan blade turns freely.   
					• 
					• 
					Check that the compressor is snug on all mounting pads.   
					See the nameplate on the rear panel, and check that your voltage supplied   
					corresponds with the voltage specified on the nameplate.   
					B. How to Remove Panels   
					See Fig. 1   
					• Front Panel: Remove the screw. Lift up   
					and towards you.   
					Top Panel   
					Screw   
					Screw   
					• Top Panel: Open the door. Remove the   
					screws. Lift up at the front slightly, push   
					rearward, and lift off.   
					Door   
					Front Panel   
					Fig. 1   
					Screw   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				C. Location   
					CAUTION   
					This icemaker is not intended for outdoor use. Normal operating ambient   
					temperature should be within +45°F to +100°F (+7°C to +38°C); Normal   
					operating water temperature should be within +45°F to +90°F (+7°C to +3ꢀ°C).   
					Operation of the icemaker, for extended periods, outside of these normal   
					temperature ranges may affect icemaker performance.   
					For best operating results:   
					• Icemaker should not be located next to ovens, grills or other high heat producing   
					equipment.   
					• Location should provide a firm and level foundation for the equipment.   
					• Allow ꢀ4" (61 cm) clearance at top to allow for removal of the auger and for ease of   
					maintenance and/or service should they be required.   
					D. Setup   
					1) Attach the four adjustable legs provided to the bottom of the icemaker.   
					ꢀ) Position the icemaker in the selected permanent location.   
					3) Level the icemaker from side-to-side and front-to-rear by adjusting the legs.   
					E. Electrical Connection   
					WARNING   
					The GREEN ground wire in the factory-installed power cord is connected   
					to a screw on the bracket where the cord enters the machine. If it becomes   
					necessary to remove or replace the power cord, be sure to connect the power   
					cord's ground wire to this screw upon reattachment.   
					• Electrical connections must be installed in accordance with applicable national, state   
					and local regulations.   
					• The unit requires an independent power supply. See the nameplate for proper voltage   
					and breaker/fuse size.   
					• Usually an electrical permit and services of a licensed electrician are required.   
					F. Water Supply and Drain Connections   
					• Water supply inlet is 1/ꢀ" female pipe thread (FPT).   
					• A water supply line shut-off valve and drain valve must be installed. A minimum of   
					3/8" OD copper tubing is recommended for the water supply lines.   
					• Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG.   
					If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.   
					• Drain outlet is 3/4" FPT.   
					• Drain line must have 1/4" fall per foot (ꢀ cm per 1 m) on horizontal runs to get good   
					flow. A vented tee connection is also required for proper flow.   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				• Drain line should not be piped directly to the sewer system. An air gap of a minimum of   
					ꢀ vertical inches (5 cm) should be between the end of the drain pipe from the unit and   
					the floor drain.   
					• This icemaker must be installed in accordance with applicable national, state, and local   
					regulations.   
					• A plumbing permit and services of a licensed plumber may be required in some areas.   
					Fig. 2   
					Water Supply Inlet   
					1/ꢀ" FPT   
					Shut-Off   
					Valve   
					Piping to   
					approved   
					drain.   
					Drain Outlet   
					3/4" FPT   
					Drain Valve   
					Two-inch   
					(5 cm) air gap   
					Floor   
					Drain   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				G. Final Checklist   
					1) Is the icemaker level?   
					ꢀ) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F   
					(+7°C to +38°C) and the water temperature within +45°F to +90°F (+7°C to +3ꢀ°C) all   
					year around?   
					3) Is there at least ꢀ4" (61 cm) clearance at top for maintenance or service?   
					4) Have the shipping carton and all tape and packing been removed from the icemaker?   
					5) Are all components, fasteners, and thumbscrews securely in place?   
					6) Have all electrical and piping connections been made?   
					7) Has the power supply voltage been checked or tested against the nameplate rating?   
					And has a proper ground been installed to the icemaker?   
					8) Are the water supply line shut-off valve and drain valve installed? Has the water   
					supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of   
					113 PSIG?   
					Note: The icemaker may stop running when the water supply is OFF, or if the pressure   
					is below 10 PSIG. When the proper water pressure is reached, the icemaker will   
					automatically start running again.   
					9) Are the compressor hold-down bolts snug? Have the refrigerant lines been checked to   
					make sure they do not rub or touch other lines or surfaces?   
					10) Has the bin control switch been checked for correct operation? Move the actuator   
					located on the inside of the bin top panel. The compressor should stop within   
					90 seconds, and the gear motor within 150 seconds.   
					11) Has the end user been given the instruction manual, and instructed on how to operate   
					the icemaker and the importance of the recommended periodic maintenance?   
					1ꢀ) Has the end user been given the name and telephone number of an authorized service   
					agent?   
					13) Has the warranty tag been filled out and   
					forwarded to the factory for warranty   
					registration?   
					Spout   
					14) Have the safety switch brackets moved   
					out of location during shipping? Make sure   
					they are in position as illustrated in Fig. 3.   
					Safety Bracket (A)   
					15) Has the safety switch been checked for   
					correct operation? Activate the safety   
					switch. The ice machine should shut down   
					immediately. Turn the ice machine off, then   
					back on, to reset.   
					Safety Bracket (B)   
					Safety Switch   
					Fig. 3   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				H. Startup   
					CAUTION   
					1. All parts are factory-adjusted. Improper adjustments may result in failure.   
					ꢀ. If the unit is turned off, wait for at least 3 minutes before restarting the   
					icemaker to prevent damage to the compressor.   
					1) Clean the storage bin.   
					ꢀ) Open the water supply line shut-off valve.   
					3) Make sure the power switch on the control box is in the "OFF" position. Plug the unit   
					into the electrical outlet.   
					4) Move the flush switch to the "ICE" position and move the power switch to the   
					"ON" position to start the automatic icemaking process   
					. 
					5) Replace the panels in their correct positions.   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				III. Cleaning and Maintenance   
					A. Cleaning and Sanitizing Instructions   
					IMPORTANT   
					Ensure all components, fasteners, and thumbscrews are securely in place after   
					any maintenance or cleaning is done to the equipment.   
					WARNING   
					1. HOSHIZAKI recommends cleaning this unit at least twice a year. More   
					frequent cleaning, however, may be required in some existing water   
					conditions.   
					ꢀ. To prevent injury to individuals and damage to the icemaker, do not use   
					ammonia type cleaners.   
					3. Carefully follow any instructions provided with the bottles of cleaning and   
					sanitizing solution.   
					4. Always wear liquid-proof gloves to prevent the cleaning and sanitizing   
					solutions from coming into contact with skin.   
					5. Never run the icemaker when the reservoir is empty.   
					6. After cleaning, do not use ice made from the cleaning and sanitizing   
					solutions. Be careful not to leave any solution in the storage bin.   
					1. Cleaning Solution   
					Dilute 4.8 fl. oz. (14ꢀ ml) of recommended cleaner Hoshizaki "Scale Away" or   
					"LIME-A-WAY" (Economics Laboratory, Inc.) with 0.8 gallons (3 l) of warm water. This is   
					a minimum amount. Make more solution if necessary.   
					IMPORTANT   
					For safety and maximum effectiveness, use the solution immediately after   
					dilution.   
					2. Cleaning Procedure   
					1) Close the water supply line shut-off valve.   
					ꢀ) Remove the panels. Move the power switch to the "OFF" position and unplug the unit   
					from the electrical outlet.   
					3) Remove all ice from the storage bin.   
					4) Plug the unit back in. Move the flush switch to the "FLUSH" position and move the   
					power switch to the "ON" position to drain out the water from the icemaker.   
					5) After the water has drained, move the power switch to the "OFF" position. Unplug the   
					unit.   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				6) Lift up the top insulation and unsnap the   
					bin control assembly. Lift the assembly up   
					through the insulation and set it aside. See   
					Fig. 4.   
					Bin Control   
					Assembly   
					7) Remove the top insulation.   
					8) Remove the thumbscrews attaching spout   
					(B) to the bin, then remove spout (B). See   
					Fig. 5.   
					Top Insulation   
					Fig. 4   
					9) Remove the thumbscrews attaching   
					spout (A) and safety bracket (A) to the   
					evaporator assembly, then remove   
					spout (A) and safety bracket (A). See   
					Fig. 5.   
					Thumbscrew   
					10) Pour the cleaning solution over the   
					extruding head until the evaporator   
					assembly and the reservoir are full and the   
					solution starts to overflow into the drain   
					pan.   
					Spout   
					Packing (A)   
					Safety Bracket (A)   
					Spout (A)   
					Extruding   
					Head   
					Note: If there is excess scale on the   
					extruding head, fill the evaporator   
					assembly and reservoir as described   
					above, then use a clamp on the   
					reservoir hose between the reservoir   
					and evaporator assembly to block   
					flow. Pour additional cleaning fluid   
					over the extruding head until the   
					evaporator assembly is completely   
					full.   
					Evaporator   
					Assembly   
					Cylinder   
					Packing   
					Spout (B)   
					Thumbscrew   
					11) Allow the icemaker to sit for about   
					10 minutes before operation. If you placed   
					a clamp on the reservoir hose in step 10,   
					remove it before operation.   
					Fig. 5   
					1ꢀ) Replace all parts in their correct positions. Make sure safety bracket (A) is in position as   
					illustrated in Fig. 7.   
					13) Plug the unit back in. Move the flush switch to the "ICE" position and move the power   
					switch to the "ON" position. Replace the panels in their correct positions and allow the   
					unit to make ice using the solution until it stops automatically.   
					Note: This unit is designed to start operating when the water reservoir is full.   
					14) Remove the front panel.   
					15) Move the flush switch to the "FLUSH" position to drain the remainder of the solution.   
					16) After the solution has drained, move the flush switch to the "ICE" position.   
					17) Replace the front panel in its correct position.   
					18) Open the water supply line shut-off valve to supply water to the reservoir.   
					1ꢀ   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				19) When the gear motor starts, remove the front panel and move the flush switch to the   
					"FLUSH" position to drain out the water from the icemaker.   
					ꢀ0) After the water has drained, move the power switch to the "OFF" position and unplug   
					the unit.   
					Note: If you do not sanitize the icemaker, leave the unit plugged in with the power   
					switch in the "ON" position and go to step 18 in "5. Sanitizing Procedure - Final."   
					3. Sanitizing Solution   
					Dilute ꢀ.5 fl. oz. (74 ml or 5 tbs) of a 5.ꢀ5% sodium hypochlorite solution (chlorine   
					bleach) with 5 gallons (19 l) of warm water.   
					IMPORTANT   
					For safety and maximum effectiveness, use the solution immediately after   
					dilution.   
					4. Sanitizing Procedure - Initial   
					1) Close the water supply line shut-off valve.   
					ꢀ) Remove the top panel. Remove the bin control assembly from the top insulation and   
					set it aside. Remove the top insulation.   
					3) Remove the thumbscrews attaching spout (B) to the bin, then remove spout (B).   
					4) Remove the thumbscrews attaching spout (A) and safety bracket (A) to the evaporator   
					assembly, then remove spout (A) and safety bracket (A). Remove spout packing (A)   
					and the cylinder packing. See Fig. 5.   
					5) Pour the sanitizing solution over the extruding head until the evaporator assembly and   
					the reservoir are filled and the solution starts to overflow into the drain pan.   
					6) Lift up slightly on the clip securing the bin control switch to   
					the paddle assembly and slide the switch out. See Fig. 6.   
					7) Soak the spouts, packings and paddle assembly in   
					Clip   
					.ꢀ5 gallons (1 l) of sanitizing solution for 10 minutes then   
					wipe them down.   
					8) Rinse the parts thoroughly, then replace all parts in their   
					correct positions.   
					Bin Control   
					Switch   
					9) Plug the unit back in. Move the flush switch to the "ICE"   
					position and move the power switch to the "ON" position.   
					Replace the panels in their correct positions and allow   
					Fig. 6   
					Paddle   
					Assembly   
					the unit to make ice using the solution until it stops   
					automatically.   
					5. Sanitizing Procedure - Final   
					1) Remove the front panel.   
					ꢀ) Move the flush switch to the "FLUSH" position to drain the remainder of the solution.   
					3) After the solution has drained, move the power switch to the "OFF" position and unplug   
					the unit.   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				4) Remove the top panel.   
					5) Remove the bin control assembly from the top insulation and set it aside. Remove the   
					top insulation.   
					6) Remove the thumbscrews attaching spout (B) to the bin, then remove spout (B).   
					7) Remove the thumbscrews attaching spout (A) and safety bracket (A) to the evaporator   
					assembly, then remove spout (A) and safety bracket (A).   
					8) Pour the sanitizing solution over the extruding head until the evaporator assembly and   
					the reservoir are filled and the solution starts to overflow into the drain pan.   
					9) Allow the icemaker to sit for about 10 minutes before operation.   
					10) Replace all parts in their correct positions. Make sure safety bracket (A) is in position as   
					illustrated in Fig. 7.   
					Spout   
					11) Plug the unit back in. Move the flush switch   
					to the "ICE" position and move the power   
					switch to the "ON" position. Replace the   
					panels in their correct positions and allow   
					Safety Bracket (A)   
					the unit to make ice using the solution until   
					it stops automatically.   
					1ꢀ) Remove the front panel.   
					13) Move the flush switch to the "FLUSH"   
					position to drain the remainder of the   
					solution.   
					Safety Bracket (B)   
					14) After the solution has drained, move the   
					flush switch to the "ICE" position.   
					Safety Switch   
					Fig. 7   
					15) Replace the front panel in its correct position.   
					16) Open the water supply line shut-off valve to supply water to the reservoir.   
					17) When the gear motor starts, remove the front panel and move the flush switch to the   
					"FLUSH" position to drain out the water from the icemaker.   
					18) After the water has drained, move the flush switch to the "ICE" position and allow the   
					icemaker to run. Replace the front panel in its correct position.   
					19) After 30 minutes, remove the front panel and move the power switch to the "OFF"   
					position. Unplug the unit.   
					ꢀ0) Pour warm water into the storage bin to melt all ice, then clean the bin liner with the   
					solution.   
					ꢀ1) Flush out any solution from the storage bin.   
					ꢀꢀ) Plug the unit back in. Move the power switch to the "ON" position to start the automatic   
					icemaking process.   
					ꢀ3) Replace the front panel in its correct position.   
					14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				B. Maintenance   
					IMPORTANT   
					1. This icemaker must be maintained individually, referring to the instruction   
					manual and labels provided with the icemaker.   
					ꢀ. To achieve optimum icemaker performance, the following parts need periodic   
					inspection and maintenance:   
					Extruding Head and Upper Bearing   
					Housing and Lower Bearing   
					Evaporator Cylinder   
					Auger   
					Gear Motor   
					Mechanical Seal   
					These parts should be inspected at least once a year or every 10,000   
					hours of operation. Their service life, however, depends on water quality and   
					environment. More frequent inspection and maintenance are recommended   
					in bad or severe water conditions.   
					Replacement of the following consumable parts is recommended if wear   
					exceeds factory recommendations:   
					Upper Bearing   
					Lower Bearing   
					Mechanical Seal   
					Consult with your local distributor about inspection and maintenance   
					service. To obtain the name and phone number of your local distributor, call   
					Hoshizaki Technical Support at 1-800-ꢀ33-1940 in the USA.   
					1. Stainless Steel Exterior   
					To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a   
					damp cloth containing a neutral cleaner to wipe off oil or dirt build up.   
					2. Storage Bin and Scoop   
					• Wash your hands before removing ice. Use the plastic scoop provided (bin accessory).   
					• The storage bin is for ice use only. Do not store anything else in the bin.   
					• Keep the scoop clean. Clean using a neutral cleaner and rinse thoroughly.   
					• Clean the bin liner using a neutral cleaner. Rinse thoroughly after cleaning.   
					3. Air Filters   
					Plastic mesh air filters remove dirt or dust from the air, and keep the condenser from   
					getting clogged. As the filters get clogged, the icemaker’s performance will be reduced.   
					Check the filters at least twice a month. When clogged, use warm water and a neutral   
					cleaner to wash the filters.   
					4. Condenser   
					Check the condenser once a year, and clean if required by using a brush or vacuum   
					cleaner. More frequent cleaning may be required depending on the location of the   
					icemaker.   
					15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				C. Preparing the Icemaker for Long Storage   
					CAUTION   
					When the icemaker is not used for two or three days under normal conditions, it   
					is sufficient to only move the power switch to the "OFF" position. When storing   
					the icemaker for extended time or in sub-freezing temperatures, turn the water   
					off and drain out all water from the water lines and remove the ice from the bin.   
					The bin should be cleaned and dried. Drain the icemaker water hoses using air   
					or carbon dioxide to prevent damage at sub-freezing temperatures.   
					1) Run the icemaker with the potable water supply line shut-off valve closed. Allow the unit   
					to make ice until it stops automatically.   
					ꢀ) Open the potable water supply line drain valve and blow the line out using compressed   
					air or carbon dioxide.   
					3) Remove the front panel and move the flush switch to the "FLUSH" position to drain out   
					the remaining water from the icemaker.   
					4) After the water has drained, move the power switch to the "OFF" position and unplug   
					the unit.   
					5) Replace the front panel in its correct position.   
					6) Close the potable water supply line drain valve.   
					7) Remove all ice from the storage bin and clean the bin.   
					16   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				HOSHIZAKI AMERICA, INC.   
					618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A2SA10B   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |