Honeywell Weather Radio 08060 TH106 TL6061 69 2024 User Manual |
08160
TH106
TL6160
1.
NOTE: Always keep the thermostat's vents clean and unobstructed.
Description
n
n
This programmable thermostat can be used to control an electric
heating system such as an electric baseboard heater, a radiant ceil-
ing, a radiant floor, a convector, etc.
Temperature
preset buttons
Appears when the
setpoint is displayed
Time and day
Temperature
Set the day
Set the time
Operating
mode icons
o Connect the thermostat wires to the line wires and to the load
Program the
schedule
wires using solderless connectors for copper wires.
Temperature
preset icons
Skip a period
Heating power
indicator
Select the
operating mode
Periods
2-wire installation
Temperature
adjustment
buttons
The thermostat cannot be used under the following conditions:
•
•
•
•
The resistive load is greater than 16.7 A
The resistive load is less than 2 A
The system is driven by a contactor or relay (inductive load)
The system is a central heating system
4-wire installation
SUPPLIED PARTS:
•
•
•
One (1) thermostat
Two (2) 6-32 screws
Two (2) solderless connectors
2.
Installation
o
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
p Push any excess wire back into the electrical box.
THE INSTALLATION MUST BE PERFORMED BY AN ELECTRI-
CIAN.
ꢀ
All cables and connections must conform to the local electrical
code.
ꢀ
Special CO/ALR solderless connectors must be used when con-
necting with aluminum conductors.
ꢀ
ꢀ
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing
the heater.
ꢀ
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight.
NOTE: If necessary, before re-installing the front component, config-
ure the thermostat (see section 3).
ꢀ
ꢀ
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
q Return power to heating system.
The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.
08060 / TH106 / TL6061
69-2024
1/11/06
1/3
Programmable Thermostat - Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
11.
r Press Mode to exit the programming mode.
NOTE: If no button is pressed for 60 seconds, the thermostat will
automatically exit the programming mode.
Warranty
;
Honeywell warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and ser-
vice, for a period of one (1) year from the date of purchase by the
consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, Honeywell shall repair or
replace it (at Honeywell's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it, or
8.
Power Outage
In the event of a power outage, most settings are saved. Only the
u
time must be re-adjusted if the power outage lasts more than 2 hours.
The thermostat will return to the mode that was active prior to the
power outage.
9.
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer
Care will make the determination whether the product should be
returned to the following address: Honeywell Return Goods,
Dock 4 MN10-3860, 1885 Douglas Dr N, Golden Valley, MN
55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by Honeywell that the defect or
malfunction was caused by damage which occurred while the prod-
uct was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the prod-
uct within the terms stated above. HONEYWELL SHALL NOT BE
LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING
ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so this limitation may not
apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEY-
WELL MAKES ON THIS PRODUCT. THE DURATION OF ANY
IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF
THIS WARRANTY. Some states do not allow limitations on how long
an implied warranty lasts, so the above limitation may not apply to
you.
Troubleshooting
v
PROBLEM
SOLUTIONS
This condition is normal. Under normal
operation, the thermostat housing can
reach a temperature between 95 °F
(35 °C) and 104 °F (40 °C).
Thermostat is hot.
The measured temperature is below the
display range. Heating is activated.
LO is displayed.
HI is displayed.
The measured temperature is above the
display range.
Wrong temperature is
displayed.
The thermostat is exposed to air draft.
Eliminate the draft.
The thermostat was without power for
more than 2 hours.
Wrong time is displayed.
Temperature does not
Check that the thermostat is in Automatic
change according to the mode. Check the schedule and clock set-
programmed schedule. tings.
The thermal protection device on the
Display disappears and
heater is open. This can happen after a
reappears after a few
power failure or if the heater is obstructed
minutes.
by furniture or curtains.
Display looks faded
when heating is acti-
vated
The heating system is less than the
required minimum load. This thermostat
cannot be used below that rating.
This warranty gives you specific legal rights, and you may have other
rights which vary from state to state.
10.
If you have any questions concerning this warranty, please write Hon-
eywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN
55422 or call 1-800-468-1502. In Canada, write Retail Products
ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive,
Technical Specifications
w
Power: 120/208/240 VAC, 60 Hz
Minimum load: 2 A (resistive only)
250 W @ 120 VAC
Scarborough, Ontario M1V4Z9.
12.
400 W @ 208 VAC
500 W @ 240 VAC
Customer Assistance
ꢀ
Maximum load: 16.7 A (resistive only)
2000 W @ 120 VAC
If you have any questions about the operation of your thermostat,
Customer Care toll-free at 1-800-468-1502.
3500 W @ 208 VAC
4000 W @ 240 VAC
Display range: 32 °F to 140 °F (0 °C to 60 °C)
Display resolution: 1 °F (0.5 °C)
®
As an ENERGY STAR partner, Honeywell has
determined that this product meets the ENERGY STAR
guidelines for energy efficiency.
Setpoint range: 40 °F to 86 °F (5 °C to 30 °C)
Setpoint interval: 1 °F (0.5 °C)
Storage: -4 °F to 120 °F (-20 °C to 50 °C)
Certification: c UL us
08060 / TH106 / TL6061
69-2024
1/11/06
3/3
Programmable Thermostat - Installation and User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
|