Fixing the adapter by screw which is offered.
(Must use the machine screw to the outlet box.)
(Must use the tapping screw to the wood wall.)
To remove the panel, push inward the locking tab and then pull out the
panel towards the opposite side.
•
Service life and warranty period
Residential Flammable Gas Leakage
Detector (RFR200)
1. The optimal service life is five years (since the purchase, please keep
your invoice).
While installation, ensure the wire is routed out through the reserved hole
before installation. AC wire have to go through the adapter hole. Please
check the direction of adapter and check the arrow and “UP” mark.
Fix the host onto the adapter for mounting with screws.
2. The warranty period for free is one year (since the purchase).
3. User must read through this instruction manual carefully and operate
correctly, and Honeywell will repair or replace for free in case the machine
does not work due to any quality issue at the manufacturer’s side.
Operation Instructions
Thank you for choosing Honeywell gas leakage alarm system. Please
carefully read through the instructions before using this product, and perform
according to the relevant procedures as provided herein to avoid any damage
to this machine or any other incidents incurred by your inappropriate
operation.
The user shall assume any liability arising from or in connection with his
or her failure to comply with the instructions in this manual and part
installation, repair or replacement by unauthorized person.
For the product, its color and style, please refer to the actual product as
standard.
•
•
•
Operation Standard: GB15322.2-2003
Detection Gas :LNG
Installation instruction
The detector should be installed in the room with gas consumed
equipment, and the alarm shall have a horizontal distance of 3m or less from
the gas consumed equipment. In case natural gas is used, the detector may
be installed at the height with a 30m distance or less from the ceiling.
•
Procedures for remote sensor installation
Fix the sensor onto the ceiling with screws.
Please keep this manual in a safe place for future reference. If you should
have any doubt or dissatisfaction with our product or service, including
product technology, quality, installation and maintenance, please contact us
immediately so that we can deal with your suggestions in a proper way.
Flush mounting — in case flush mounting is selected, the adapter for
mounting is not necessarily used. You need to dis-connect the AC power wire
and remote sensor wire from main Assy and take off the adapter first.
Remote sensor
30cm or less
•
Product profile
As the gas detection expert, Honeywell Analytics brings together nearly
connector
Remote sensor
cable
3m or less
200 collective years of expertise in design, manufacture and technology. As
the leader in gas detection and alarm equipment industry in the world, we
apply high-precision detection standards to domestic gas leakage alarm
systems. By integration of powerful catalytic flammable sensing technology
and advanced electronic technology, Honeywell is dedicated to providing
multiple protections for both our customers and their properties.
1.2m-1.6m
Detecting natural gas
•
Function and indication chart
Cut off the strip on the left edge of the host with a knife, and fixed the
machine body into the groove previously excavated on the wall with screws
(detailed dimensions of the groove: width 134mm~136mm, height 92mm~
93mm).
•
Incorrect mounting position
B
u
z
LED
Relay
Operation
1. Places where exhaust, steam and oil smoke from gas appliances may
directly influence
Description
Timing/Interval
G R Y Al Ft
Y N N De En
z
2. Places near to the air inlet, exhaust fan, door and window where
favorable ventilation is ensured
3. Places which are fenced off by the window curtain, vertical curtain,
cabinet door, ceiling and cross beam, etc.
4. Places with high temperature and moisture like cooking room and boiler
room, etc.
5. Places where power supply of the alarm may possibly be switched off
6. Places outdoor or where the temperature is lower than -10 °C or higher
than +55 °C
Check that each part or component is in good condition before
installation, and get prepared the screws and other attachments we’ve
provided in the toolkit.
Always G LED on if
power is normal
Normal
When no gas is present, the green
LED
N
Y
Operation
On demand test result by press the
button. Red LED and Yellow LED will
be blink in order. After then return to
normal mode
On demand test result by press the
button. After then return to normal
mode
8 times beep with red
LED flash 4 times and
then yellow LED flash
4 times
Successful
Test*
Y Y Y En En
Y N Y De De
• Part description
Control panel
Unsuc-
Same as default condition
N
Y
cessful Test
When detects gas, it will give the
alarm signal continuously. The red
LED and sounder will annunciate
When gas level is less then alarm
point, return to normal operation.
Cut off
8 times beep with red
LED flash 8 times
Alarm
Y Y N En En
Front cover assy
Strain relief
•
Precautions on using
1. Do not switch off the power supply of the alarm, otherwise the alarm may
not work when gas leakage occurs.
If relay is used for signal output, then remove the wire trunking and fix it
with screws again after connecting the signal line to the corresponding
connecting terminal.
If required, the audible alarm can be
silenced for 5 minutes by pushing
the button marked “Test”. The red
alarm will continue to flash for 5
minutes
Hush
Function
Red LED flash 4 times
each time
2. Do not touch any part of the power supply with wet hand(s) as this could
cause risk of electric shock.
3. Do not remove or retrofit the alarm.
Y Y N En En
Y Y N En En
N
Y
If gas is still present after 5 minutes
hush period, the audible alarm will
sound
4. Do not use volatile matters in the vicinity of the alarm, like hair spray,
pesticide, paint, adhesive agent and alcohol, so as to avoid false alarm an
eliminate any influence on the service life of the sensitive elements.
5. Do not eject high-concentration gas into the access opening to avoid
performance of the sensor.
6. Frequently check the power LED (green) is always on.
7. Press down the self-test button of the detector once every 6 months to
check it is in normal standby state.
8. In case a fault happens in the alarm, please contact our company or the
local representative office immediately.
9
10. Prevent the product from falling down from a high level during installation
and operation, otherwise the performance of the product may be impaired.
11. Never attempt to replace the remote probe or change the length of its
wire by any unauthorized person.
Main assy
Same as alarm condition
Y N Y De De
Y N Y De De
N N Y De De
Y
Y
Y
Y
3 long chirps/min
1 long chirps/min
2 long chirps/min
Continues beep
End of life time(5 years)
Cell health trouble/No cell
Power trouble
Trouble
Condition
Adapter
Never connect the power supply to any signal output terminal.
EEPROM CRC fail/ Program
code fail
NC:Normal close
COM
NC
N N Y
De De
Remote sensor
Fault
COM
Alarm
Screw
NO:Normal open
* Alarm relay shall be teseted often 5 seconds of button when normal conduction.
Power LED (green)
Alarm LES (red)
Fault (yellow)
12. Never clean the alarm with a cleaning agent.
13. Please keep the alarm away from silicon-contained material.
•
Our company will not assume any responsibility for
product damage or loss of function caused by the
Remote sensor
following reasons:
1. Consumer’s disassembly or intentional damage
2. Force majored like fire, earthquake, lightening, abnormal voltage, etc.
3. Wrong installation position or failure to switch on power supply of the
detector
•
Procedures for control panel installation
Find an appropriate installation point on the wall.
Press down the panel onto the host to complete the installation.
4. Expiration of the lifetime
5. Falling down, impact and other faults and damages incurred by the
consumer
6. Other contamination, damages, faults or damages not caused by the
manufacturer
Honeywell Trading (Shanghai) Ltd
430 Li Bing Road
Zhangjiang Hi-Tech Park
1. Power LED (green): indicates the power system is in normal operation
2. Alarm LED (red): indicates the concentration of combustible gas
leakage reaches the set value
Shanghai, China
H_RFI Manual_09_V1_AP
3. Fault LED (yellow): indicates the alarm is in fault condition