Honeywell Carbon Monoxide Alarm RFR200 User Manual

Fixing the adapter by screw which is offered.  
(Must use the machine screw to the outlet box.)  
(Must use the tapping screw to the wood wall.)  
To remove the panel, push inward the locking tab and then pull out the  
panel towards the opposite side.  
Service life and warranty period  
Residential Flammable Gas Leakage  
Detector (RFR200)  
1. The optimal service life is ve years (since the purchase, please keep  
your invoice).  
While installation, ensure the wire is routed out through the reserved hole  
before installation. AC wire have to go through the adapter hole. Please  
check the direction of adapter and check the arrow and “UP” mark.  
Fix the host onto the adapter for mounting with screws.  
2. The warranty period for free is one year (since the purchase).  
3. User must read through this instruction manual carefully and operate  
correctly, and Honeywell will repair or replace for free in case the machine  
does not work due to any quality issue at the manufacturer’s side.  
Operation Instructions  
Thank you for choosing Honeywell gas leakage alarm system. Please  
carefully read through the instructions before using this product, and perform  
according to the relevant procedures as provided herein to avoid any damage  
to this machine or any other incidents incurred by your inappropriate  
operation.  
The user shall assume any liability arising from or in connection with his  
or her failure to comply with the instructions in this manual and part  
installation, repair or replacement by unauthorized person.  
For the product, its color and style, please refer to the actual product as  
standard.  
Operation Standard: GB15322.2-2003  
Detection Gas :LNG  
Installation instruction  
The detector should be installed in the room with gas consumed  
equipment, and the alarm shall have a horizontal distance of 3m or less from  
the gas consumed equipment. In case natural gas is used, the detector may  
be installed at the height with a 30m distance or less from the ceiling.  
Procedures for remote sensor installation  
Fix the sensor onto the ceiling with screws.  
Please keep this manual in a safe place for future reference. If you should  
have any doubt or dissatisfaction with our product or service, including  
product technology, quality, installation and maintenance, please contact us  
immediately so that we can deal with your suggestions in a proper way.  
Flush mounting — in case ush mounting is selected, the adapter for  
mounting is not necessarily used. You need to dis-connect the AC power wire  
and remote sensor wire from main Assy and take off the adapter rst.  
Remote sensor  
30cm or less  
Product prole  
As the gas detection expert, Honeywell Analytics brings together nearly  
connector  
Remote sensor  
cable  
3m or less  
200 collective years of expertise in design, manufacture and technology. As  
the leader in gas detection and alarm equipment industry in the world, we  
apply high-precision detection standards to domestic gas leakage alarm  
systems. By integration of powerful catalytic ammable sensing technology  
and advanced electronic technology, Honeywell is dedicated to providing  
multiple protections for both our customers and their properties.  
1.2m-1.6m  
Detecting natural gas  
Function and indication chart  
Cut off the strip on the left edge of the host with a knife, and xed the  
machine body into the groove previously excavated on the wall with screws  
(detailed dimensions of the groove: width 134mm~136mm, height 92mm~  
93mm).  
Incorrect mounting position  
B
u
z
LED  
Relay  
Operation  
1. Places where exhaust, steam and oil smoke from gas appliances may  
directly inuence  
Description  
Timing/Interval  
G R Y Al Ft  
Y N N De En  
z
2. Places near to the air inlet, exhaust fan, door and window where  
favorable ventilation is ensured  
3. Places which are fenced off by the window curtain, vertical curtain,  
cabinet door, ceiling and cross beam, etc.  
4. Places with high temperature and moisture like cooking room and boiler  
room, etc.  
5. Places where power supply of the alarm may possibly be switched off  
6. Places outdoor or where the temperature is lower than -10 °C or higher  
than +55 °C  
Check that each part or component is in good condition before  
installation, and get prepared the screws and other attachments we’ve  
provided in the toolkit.  
Always G LED on if  
power is normal  
Normal  
When no gas is present, the green  
LED  
N
Y
Operation  
On demand test result by press the  
button. Red LED and Yellow LED will  
be blink in order. After then return to  
normal mode  
On demand test result by press the  
button. After then return to normal  
mode  
8 times beep with red  
LED ash 4 times and  
then yellow LED ash  
4 times  
Successful  
Test*  
Y Y Y En En  
Y N Y De De  
• Part description  
Control panel  
Unsuc-  
Same as default condition  
N
Y
cessful Test  
When detects gas, it will give the  
alarm signal continuously. The red  
LED and sounder will annunciate  
When gas level is less then alarm  
point, return to normal operation.  
Cut off  
8 times beep with red  
LED ash 8 times  
Alarm  
Y Y N En En  
Front cover assy  
Strain relief  
Precautions on using  
1. Do not switch off the power supply of the alarm, otherwise the alarm may  
not work when gas leakage occurs.  
If relay is used for signal output, then remove the wire trunking and x it  
with screws again after connecting the signal line to the corresponding  
connecting terminal.  
If required, the audible alarm can be  
silenced for 5 minutes by pushing  
the button marked “Test”. The red  
alarm will continue to ash for 5  
minutes  
Hush  
Function  
Red LED ash 4 times  
each time  
2. Do not touch any part of the power supply with wet hand(s) as this could  
cause risk of electric shock.  
3. Do not remove or retrot the alarm.  
Y Y N En En  
Y Y N En En  
N
Y
If gas is still present after 5 minutes  
hush period, the audible alarm will  
sound  
4. Do not use volatile matters in the vicinity of the alarm, like hair spray,  
pesticide, paint, adhesive agent and alcohol, so as to avoid false alarm an  
eliminate any inuence on the service life of the sensitive elements.  
5. Do not eject high-concentration gas into the access opening to avoid  
performance of the sensor.  
6. Frequently check the power LED (green) is always on.  
7. Press down the self-test button of the detector once every 6 months to  
check it is in normal standby state.  
8. In case a fault happens in the alarm, please contact our company or the  
local representative ofce immediately.  
9
10. Prevent the product from falling down from a high level during installation  
and operation, otherwise the performance of the product may be impaired.  
11. Never attempt to replace the remote probe or change the length of its  
wire by any unauthorized person.  
Main assy  
Same as alarm condition  
Y N Y De De  
Y N Y De De  
N N Y De De  
Y
Y
Y
Y
3 long chirps/min  
1 long chirps/min  
2 long chirps/min  
Continues beep  
End of life time(5 years)  
Cell health trouble/No cell  
Power trouble  
Trouble  
Condition  
Adapter  
Never connect the power supply to any signal output terminal.  
EEPROM CRC fail/ Program  
code fail  
NC:Normal close  
COM  
NC  
N N Y  
De De  
Remote sensor  
Fault  
COM  
Alarm  
Screw  
NO:Normal open  
* Alarm relay shall be teseted often 5 seconds of button when normal conduction.  
Power LED (green)  
Alarm LES (red)  
Fault (yellow)  
12. Never clean the alarm with a cleaning agent.  
13. Please keep the alarm away from silicon-contained material.  
Our company will not assume any responsibility for  
product damage or loss of function caused by the  
Remote sensor  
following reasons:  
1. Consumer’s disassembly or intentional damage  
2. Force majored like re, earthquake, lightening, abnormal voltage, etc.  
3. Wrong installation position or failure to switch on power supply of the  
detector  
Procedures for control panel installation  
Find an appropriate installation point on the wall.  
Press down the panel onto the host to complete the installation.  
4. Expiration of the lifetime  
5. Falling down, impact and other faults and damages incurred by the  
consumer  
6. Other contamination, damages, faults or damages not caused by the  
manufacturer  
Honeywell Trading (Shanghai) Ltd  
430 Li Bing Road  
Zhangjiang Hi-Tech Park  
1. Power LED (green): indicates the power system is in normal operation  
2. Alarm LED (red): indicates the concentration of combustible gas  
leakage reaches the set value  
Shanghai, China  
H_RFI Manual_09_V1_AP  
3. Fault LED (yellow): indicates the alarm is in fault condition  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Car Seat 8H98 User Manual
Grizzly Sander G0723 User Manual
Haier Convection Oven MWM10100GCSS User Manual
Harbor Freight Tools Nail Gun 66995 User Manual
Harbor Freight Tools Security Camera 67139 User Manual
Hotpoint Cooktop GW38G User Manual
HP Hewlett Packard Network Card NetMail 3000 User Manual
Husqvarna Chainsaw 315 320 User Manual
Image Home Gym IMBE39401 User Manual
IMC Networks Switch AccessEtherLinx 4 User Manual