Owner’s Manual
Installation and Operation
TIARA PETITE B
DIRECT VENT ROOM HEATER
Model:
Portland
Tested and
Listed by
O-T L
Oregon USA
C
US
TIARAP-BK
TIARAP-BR
TIARAP-CES
TIARAP-CTO
OMNI-Test Laboratories, Inc.
CAUTION
DO NOT DISCARD THIS MANUAL
•
Read, understand and
follow these instructions
for safe installation and
operation.
•
Important operating and
maintenance instructions
included.
•
Leave this manual with
party responsible for use
and operation.
WARNING
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
Hot glass will cause burns.
•
Do not touch glass until it is cooled
• NEVER allow children to touch glass
• What to do if you smell gas
•
•
Keep children away
CAREFULLY SUPERVISE children in the same room
as appliance
- Do not try to light any appliance.
Do not touch any electrical switch. Do not
use any phone in your building.
• Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
•
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
Keep clothing, furniture, draperies and other
combustibles away.
- If you cannot reach your gas supplier, call
In the Commonwealth of Massachusetts:
the fire department.
•
installation must be performed by a licensed plumber or gas
fitter.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
See Table of Contents for additional Commonwealth of Mas-
sachusetts requirements.
This appliance may be installed as an OEM installation in manufactured
home (USA only) or mobile home and must be installed in accordance with
the manufacturer's instructions and the manufactured home construction and
safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised by an NFI
certified professional.
This appliance is only for use with the type(s) of gas indicated on the rating plate.
7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
- TABLE OF CONTENTS -
Section 7: Electrical Information
Section 1: Listing and Code Approvals
A. Appliance Certifications ......................4
B. Glass Specifications............................4
C. Specifications......................................4
D. High Altitude Installations....................4
E. Non-Combustible Materials.................4
F. Combustible Materials ........................4
G. Requirements for the
A. Recommendation for Wire ..................29
B. Connecting to the Appliance...............29
C. Standing Pilot Ignition System
Wiring..................................................29
D. Ignition Module Access and
Battery Replacement ..........................30
Section 8: Appliance Setup
Commonwealth of Massachusetts......5
A. Remove Shipping Materials................31
B. Accessories.........................................31
B. Leg Leveling System...........................31
C. Flue Restrictor Installation ..................32
D. Intake Damper Operation....................32
E. Intake Air Shutter Adjustment .............32
F. Positioning the Logs............................32
G. Mineral Wool.......................................33
H. Accessories.........................................33
I. Blower Installation...............................34
J. Warming Shelves Installation..............37
K. Glass Replacement.............................37
Section 2: Getting Started
A. Design & Installation
Considerations....................................6
B. Tools and Supplies Needed................6
C. Inspect Appliance & Components.......6
Section 3: Appliance Location & Clearances
A. Selecting Appliance Location..............7
B. Clearances to Combustibles...............7
Section 9: Operating Instructions
Section 4: Termination Locations
A. Vent Termination Minimum
A. Before Lighting Appliance...................38
B. Controls...............................................38
C. Lighting Appliance...............................39
D. After Appliance is Lit ...........................40
E. Frequently Asked Questions...............40
Clearances..........................................8
Section 5: Vent Information
A. Venting Components..........................10
B. Use of Elbows.....................................10
C. Measuring Standards..........................10
D. How to Use the Vent Graph................11
E. Venting Guidelines..............................11
F. Horizontal Termination........................12
G. Vertical Termination............................15
H. Slim Line Wall Thimble .......................23
Section 10: Troubleshooting...............................41
Section 11: Maintaining & Servicing Appliance
A. Maintenance Tasks .............................43
Section 12: Reference Materials
A. Appliance Dimension Diagram ...........45
B. Vent Components Diagram ................46
C. Vent Components List ........................47
D. Service Parts List................................49
E. Accessories ........................................53
F. Service and Maintenance Log............54
G. Warranty Policy...................................55
H. Contact Information ............................56
Section 6: Gas Information
A. Fuel Conversions................................25
B. Gas Pressures....................................27
C. Gas Connection.. ................................27
ꢀ
= Contains updated information.
August 1, 2008
Heat & Glo · Tiara Petite B · 7026-101K
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Listing and Code Approvals
1
C. Specifications
A. Appliance Certification
Maxi-
mum
Input
BTU
Mini-
mum
Input
BTU
Orifice
Size
(DMS) Efficiency
*Steady
State
**P.4
%
MODEL
Tiara Petite B
Model
(US or Canada)
LABORATORY OMNI-Test Laboratories, Inc.
%
061-S-47b-5
Tiara Petite B (NG)
Tiara Petite B (LP)
17,000 12,000
17,000 13,000
49
56
73.93
78.19
57.30
63.22
TYPE
Vented Gas Fireplace Heater
STANDARD
ANSI Z21.88b-2003 ּ CSA 2.33b-2003ּ
UL307b ּ CAN/CBA 2.17-M91
*Maximum Vent Blower On
**Canada Only
The product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burning
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles” and "Gas Fired Appliances for use at High
Altitudes".
D. High Altitude Installations
Omni-Test Laboratories, Inc. listed gas appliances are tested
and approved without requiring changes for elevations from 0
to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.
Manufactured Home or Mobile Home installation may occur
only after the home is site located and must conform with
the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or, when such a standard is
not applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA
Z240.4.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. If the heating value of the
gas has been reduced, these rules do not apply. To identify
the proper orifice size, check with the local gas utility.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
E. Non-Combustible Materials
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750°C, shall be considered non-combustible
materials.
B. Glass Specifications
This appliance is equipped with 5mm ceramic glass behind
the curved glass. Replace glass only with 5mm ceramic
glass. Please contact your dealer for replacement glass.
F. Combustible Materials
Materials made of or surfaced with wood, compressed
paper, plant fibers, plastics, or other materials that can ignite
and burn, whether flame proofed or not, or whether plastered
or unplastered shall be considered combustible materials.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the CAN/CGA B149 Installation Codes in Canada.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
Page 4
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspection
NOTE: The following requirements reference various
Massachusetts and national codes not contained in this
document.
The state or local gas inspector of the side wall horizontally
vented gas fueled equipment shall not approve the installa-
tion unless, upon inspection, the inspector observes carbon
monoxide detectors and signage installed in accordance with
the provisions of 248 CMR 5.08(2)(a) 1 through 4.
G. Requirements for the Commonwealth of
Massachusetts
Exemptions
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in whole
or in part for residential purposes, including those owned or
operated by the Commonwealth and where the side wall
exhaust vent termination is less than seven (7) feet above
finished grade in the area of the venting, including but not
limited to decks and porches, the following requirements
shall be satisfied:
The following equipment is exempt from 248 CMR 5.08(2)(a)
1 through 4:
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition of
NFPA 54 as adopted by the Board; and
•
•
Product Approved side wall horizontally vented gas fueled
equipment installed in a room or structure separated from
the dwelling, building or structure used in whole or in part
for residential purposes.
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas fitter shall
observe that a hard wired carbon monoxide detector with an
alarm and battery back-up is installed on the floor level where
the gas equipment is to be installed. In addition, the installing
plumber or gas fitter shall observe that a battery operated or
hard wired carbon monoxide detector with an alarm is installed
on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equip-
ment. It shall be the responsibility of the property owner to
secure the services of qualified licensed professionals for the
installation of hard wired carbon monoxide detectors.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas fueled equipment provides a vent-
ing system design or venting system components with the
equipment, the instructions provided by the manufacturer for
installation of the equipment and the venting system shall
include:
•
Detailed instructions for the installation of the venting sys-
tem design or the venting system components; and
In the event that the side wall horizontally vented gas fueled
equipment is installed in a crawl space or an attic, the hard
wired carbon monoxide detector with alarm and battery back-
up may be installed on the next adjacent floor level.
•
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
In the event that the requirements of this subdivision can not
be met at the time of completion of installation, the owner shall
have a period of thirty (30) days to comply with the above
requirements; provided, however, that during said thirty (30)
day period, a battery operated carbon monoxide detector with
an alarm shall be installed.
When the manufacturer of a Product Approved side wall hor-
izontally vented gas fueled equipment does not provide the
parts for venting the flue gases, but identifies “special vent-
ing systems”, the following requirements shall be satisfied by
the manufacturer:
•
The referenced “special venting system” instructions shall
be included with the appliance or equipment installation
instructions; and
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance
with the above provisions shall comply with NFPA 720 and
be ANSI/UL 2034 listed and IAS certified.
•
The “special venting system” shall be Product Approved
by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
Signage
A metal or plastic identification plate shall be permanently
mounted to the exterior of the building at a minimum height
of eight (8) feet above grade directly in line with the exhaust
vent terminal for the horizontally vented gas fueled heating
appliance or equipment. The sign shall read, in print size no
less than one-half (1/2) inch in size, “GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
A copy of all installation instructions for all Product Approved
side wall horizontally vented gas fueled equipment, all vent-
ing instructions, all parts lists for venting instructions, and/or
all venting design instructions shall remain with the appli-
ance or equipment at the completion of the installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Page 5
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
2
C. Inspect Appliance & Components
A
. Design & Installation Considerations
Heat & Glo direct vent gas appliances are designed to oper-
ate with all combustion air drawn from outside of the building
and all exhaust gases expelled to the outside. No additional
air source is required.
WARNING
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state
and national codes and regulations.
Report damaged parts to dealer.
• Consult local building, fire officials or authorities having
jurisdiction about restrictions, installation inspection,
and permits.
• Carefully remove the appliance and components from
the packaging.
• Remove cast door and glass door, and set aside on pro-
When planning an installation, it is necessary to determine
the following information before installing:
tective surface.
• Remove log set and component pack from firebox.
• Where the appliance is to be installed.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
•
The vent system configuration to be used.
• Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benefit.
• Gas supply piping.
• Electrical wiring.
• Whether optional accessories - devices such as a blower,
thermostat or remote control - are desired.
WARNING
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
WARNING
Keep appliance dry.
• Mold or rust may cause odors.
• Water may damage controls.
• Installation and use of any damaged appliance or vent
system component.
• Modification of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available. Note: Not all
tools will apply to every installation.
Any such action may cause a fire hazard.
Reciprocating saw
Pliers
Variable Speed Drill/Driver
Wrench Set
Hammer
Framing Square
Phillips Screwdriver
Framing Material
Flat Blade Screwdriver Hi temp caulking material
Plumb Line
Level
Voltmeter
Gloves
Manometer
Tape Measure
Safety Glasses
Non-corrosive Leak Check Solution
or combustible gas detector
Page 6
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance Location and Clearances
3
NOTE:
WARNING
Fire Risk
Provide adequate clearance:
· Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
· Illustrations/diagrams are not drawn to scale.
•
•
•
Around air openings
To combustibles
For service access
· Actual installation may vary due to individual design
preference.
Locate appliance away from traffic areas.
A. Selecting Appliance Location
WARNING
When selecting a location for your appliance it is important to
consider the required clearances to wall (see Figure 3.1).
Fire Risk.
•
Locate and install appliance to all
clearance specifications in manual.
NOTE: For actual appliance dimensions refer to
Section 12.
B. Clearances to Combustibles
F
G -Alcove
C
B
H
A
A
D
A
A
C
E
"A" measurement is from
stove top, not side
Model
A
6
B
2
C
2
D
43
E
F
G
H
Inches
Tiara
Petite B
36
30
20-1/4
527
19-1/2
495
Millimeters
152
51
51
1092
914
762
Figure 3.1
It is permissable to place the appliance on carpet.
WARNING
CAUTION
Fire Risk.
Odor Risk.
Tipping Risk
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
•
Install appliance on a stable, level platform/
floor strong enough to support appliance
without tipping.
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
•
USE wood flooring, ceramic tile, brick hearth
or high pressure laminate flooring applied
directly over the sub-flooring material.
Page 7
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Termination Locations
4
A. Vent Termination Minimum Clearances
HORIZONTAL
OVERHANG
WARNING
Fire Risk.
2 FT.
MIN.
20 INCHES MIN.
VERTICAL
WALL
Explosion Risk.
LOWEST
DISCHARGE
OPENING
Maintain vent clearance to combustibles
as specified.
GAS DIRECT VENT
TERMINATION CAP
•
Do not pack air space with insulation or
other materials.
X
12
Failure to keep insulation or other materials
away from vent pipe may cause fire.
ROOF PITCH
IS X/ 12
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Measure vertical clearances from this surface.
Roof Pitch
H (Min.) Ft.
Flat to 6/12 ........................................................ 1.0*
Over 6/12 to.7../.1..2.................................................1.25*
Over 7/12 to 8/12 .............................................. 1.5*
Over 8/12 to 9/12 .............................................. 2.0*
Over 9/12 to 10/12 ............................................ 2.5*
Over 10/12 to 11/12 .......................................... 3.25
Over 11/12 to 12/12 .......................................... 4.0
Over 12/12 to 14/12 .......................................... 5.0
Over 14/12 to 16/12 .......................................... 6.0
Over 16/12 to 18/12 .......................................... 7.0
Over 18/12 to 20/12 .......................................... 7.5
Over 20/12 to 21/12 .......................................... 8.0
* 3 foot minimum in snow regions
Measure horizontal clearances from this surface.
(See Figure 4.4 for specific clearances.)
Figure 4.1 Termination Clearances
GAS, WOOD OR FUEL
OIL TERMINATION
B
Figure 4.3 Minimum Height from Roof to Lowest Discharge
Opening
GAS
TERMINATION
C
Figure 4.3 specifies minimum vent heights for various
pitched roofs.
A
Gas
Wood & Fuel Oil
Termination
Comments
Termination
A
B
C
6 in.
20 in.
18 in.
20 in. min.
24 in. min.
18 in.
Horizontal distance between terminations
Distance to perpendicular wall
Vertical distance between terminations
Figure 4.2 Multiple Vertical Temination
Page 8
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
M
N
P
R
G
v
v
A
H
D
Q
(See Note 2)
v
V
T
B
L
U.S.
B
v
(3 FT)
v
v
B
v
S
S
Electrical
Service
V
V
F
M
I
D*
V
v
X
A
J or K
X
= VENT TERMINAL
= AIR SUPPLY INLET
= AREA WHERE TERMINAL IS NOT PERMITTED
V
K
= 3 ft. (U.S.A.)
A
B
= 12 inches ............. clearances above grade, veran-
6 ft. (Canada) ......... clearance to a mechanical
(See Note 1)
da, porch, deck or balcony
(powered) air supply inlet
= 12 inches ............ clearances to window or door
that may be opened, or to per-
L** = 7 ft. ......................... clearance above paved
(See Note 1)
sidewalkor a paveddriveway
manently closed window. (Glass)
locatedon public property
D*
= 18 inches ............. vertical clearance to unventilat-
ed soffit or to ventilated soffit lo-
M*** = 18 inches .............. clearance under veranda,
porch, deck, balcony or over-
hang
cated above the terminal
42 inches .............. vinyl
*30 inches............ for vinyl clad soffits and below
electrical service
9 inches .............. clearance to outside corner
S = 6 inches ................. clearance from sides of
(See Note 3)
F
=
electrical service
T
= 12 inches................ clearance above electrical
G
H
= 6 inches ............... clearance to inside corner
service
(See Note 3)
= 3 ft. (Canada) ...... not to be installed above a gas
meter/regulatorassemblywithin3
Alcove Applications
feet (90cm) horizontally from the
N
= 6 inches ................. non-vinyl sidewalls
12 inches ............... vinyl sidewalls
= 8 ft.
center-lineof the regulator
P
I
= 3 ft. .......................
= 9 inches (U.S.A.)
clearance to gas service regula-
tor vent outlet
QMIN
RMAX
1 cap
3 feet
2 x Q ACTUAL
J
____________________________________________________________________
12 inches (Canada)clearance to non-mechanical air
supply inlet to building or the
combustion air inlet to any other
appliance
2 caps
6 feet
9 feet
12 feet
1 x Q
ACTUAL
2/3 x Q ACTUAL
1/2 x Q ACTUAL
___________________________________________________________________
_
_____3___c_a__p_s______________________________________________________
4 caps
QMIN = # termination caps x 3
___
RMAX = (2 / # termination caps) xQACTUAL
NOTE:
Local codes or regulations may require different
** a vent shall not terminate directly above a sidewalk or paved
driveway which is located between two single family dwellings and
serves both dwellings.
clearances.
NOTE: Termination caps may be hot. Consider their proximity to
doors or other traffic areas.
*** only permitted if veranda, porch, deck or balcony is fully open on
a minimum of 2 sides beneath the floor, or meets Note 2.
WARNING: In the U.S.: Vent system termination is NOT permitted
in screened porches. You must follow side wall, overhang and
ground clearances as slated in the instructions.
NOTE 1: On private property where termination is less than 7 feet above
a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed
cap is suggested. (See vents components pages.)
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with
two or more sides open. You must follow side wall, overhang and
ground clearances as stated in the instructions.
NOTE 2: Termination in an alcove space (spaces only open on one side
and without an overhang) are permitted with the dimensions specified for
vinyl or non-vinyl siding and soffits. 1. There must be at least 3 feet
minimum between termination caps. 2. All mechanical air intakes within
10 feet of a termination cap must be a minimum of 3 feet below the
termination cap. 3. All gravity air intakes within 3 feet of a termination cap
must be a minimum of 1 foot below the termination cap.
Quadra-Fire assumes no responsibility for the improper perfor-
mance of the appliance when the venting system does not meet
these requirements.
NOTE 3: Location of the vent termination must not interfere with access
Figure 4.4
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING,
IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
Page 9
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Vent Information
5
A. Venting Components
B. Use of Elbows
In order to comply with applicable codes and product
warranties, use only following venting components:
CAUTION
• Hearth & Home Technologies (HHT)
• Simpson Dura-Vent
ALL vent configuration specifications MUST be followed.
•
This product is tested and listed to these
specifications.
• Selkirk Direct-Temp
•
Appliance performance will suffer if specifications are
not followed.
• Amerivent Direct
• Security Secure Vent
Diagonal runs have both vertical and horizontal vent aspects
when calculating the effects. Use the rise for the vertical
aspect and the run for the horizontal aspect. (See Figure
5.1.)
DO
NOT
USE
FIELD-FABRICATED
VENTING
COMPONENTS. Refer to the venting manufacturer’s
instructions.
Two 45° elbows may be used in place of one 90° elbow. On
45° runs, one foot of diagonal is equal to 8-1/2 in. (216mm)
horizontal run and 8-1/2 in. (216mm) vertical run. A length of
straight pipe is allowed between two elbows. (See Figure
5.1.)
This product is approved to be vented either horizontally,
through the side wall or vertically through the roof. You may
vent through a Class A or masonry chimney if an approved
adapter is used.
This appliance is a direct vent heater. All combustion air must
come directly from the outside of the building. The vent pipe
for this unit consists of an inner and an outer pipe. The inner
pipe carries the appliance exhaust out of the system, and the
outer pipe brings fresh combustion air into the appliance.
Vertical
•
A round support box/wall thimble or heat shield is
required when the venting passes through a combus-
tible wall.
8-1/2 in.
•
•
•
A support box or ceiling firestop is required when the
venting passes through a ceiling.
Roof flashing and a storm collar are required when vent-
ing passes through the roof.
Follow instructions provided with the venting for instal-
lation of these items.
Horizontal
Figure 5.1
WARNING
Fire Hazard.
C. Measuring Standards
Vertical and horizontal measurements were made using the
following standards.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
flue serving a separate solid-fuel or gas burning
appliance.
•
•
Pipe measurements are from center line to center line.
Horizontal terminations are measured to the outside of
the mounting surface (flange of termination cap). See
Figure 4.1 on page 8.
•
•
Vent this appliance directly outside.
Use separate vent system for this appliance.
•
•
Vertical terminations are measured to the top of the last
pipe before termination cap.
May impair safe operation of this appliance or
other appliances connected to the flue.
Horizontal pipe installed level with 1/4 in. rise.
Page 10
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
D. How to Use the Vent Graph
E. Venting Guidelines
Notes:
1. Measure the distance from the top of appliance to the
center of the 90° elbow. On the graph below, draw a
horizontal line from that measurement on the vertical
axis across until it intersects with the slanted line.
•
•
•
•
•
The maximum horizontal vent run is 15 ft. (5m) when the
vertical vent rise is 10 ft. (3m).
Horizontal sections require a 1/4 in. (6mm) rise for every
12 in. (305mm) of horizontal travel.
2. From the point of this intersection, draw a vertical line to
the bottom of the graph.
3. The point at which this line meets the bottom line of the
graph is the maximum length of the horizontal run.
Exterior vent diameter = 6-5/8 in. (168mm); Inner vent
diameter = 4 in. (102mm).
Example 1:
If the vertical dimension from the top of the
Horizontal sections require noncombustible support every
3 ft. (914mm) , e.g. wall straps.
appliance to the center of the 90° elbow is 7 ft. (2m), the
horizontal run to the outer wall flange must not exceed 9
ft.-8 in. (3m).
For any vertical termination a minimum of 6 ft. (2m)
vertical must be used.
.
Example 2: If the vertical dimension from the top of the
appliance is 21 ft. (6m), the horizontal run to the outer wall
flange must not exceed 4 ft.-3 in. (1m).
EXCEPTIONS FOR HORIZONTAL INSTALLATIONS:
*The maximum horizontal vent run is 30 in. (762mm).
*The maximum horizontal vent run with a 45° elbow is
18 in. (457mm).
4. Each 90° elbow is equivalent to 3 ft. (914mm) of vent
pipe and each 45° elbow is equivalent to 1 ft. (305mm)
of vent pipe, and must be subtracted from vent pipe
run. A single vertical to horizontal 90° elbow is already
calculated into the allowable 15 ft. (5m) run. Each
additional 90° elbow reduces the maximum horizontal
distance by 3 ft. (914mm).
*No external minimum rise is required.
*The minimum horizontal vent run is 6 in. (152mm).
Example: The use of three elbows would reduce the
allowable horizontal run to 9 ft. (3 - 1 = 2 elbows
x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)
Termination cap
NOTE: In the Commonwealth of Mas-
sachusetts the word damper shall be
replaced with the words flue restrictor.
25 ft. (8m)
Maximum Vertical
25'
24'
Example 2
22'
20'
18'
16'
14'
12'
10'
8'
Adjust
Intake
VERTICAL DISTANCE
FROM APPLIANCE TO
90° ELBOW
Damper
Install Flue
Restrictor
Example 1
Termination cap
6'
6 ft. (2m) Minimum
Vertical Termination
4'
2'
C
L
2'
4'
6'
8'
10'
12' 14' 15'
SLK-01TRD or an approved Termination Cap
6 in. (152mm) Minimum starter pipe
30 in. (762mm) Maximum Horizontal run with no vertical pipe and with 1/4 in.
(6mm) rise per foot. Must use approved Termination Cap.
Figure 5.2
Page 11
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
F. Horizontal Termination
WARNING
Fire Hazard.
Type A - Up & Out Installation
Exhaust Fume Risk.
TERMINATION CAP
Impaired Performance of Appliance.
90° ELBOW
CENTER LINE
•
•
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.
PIPE LENGTH
WALL THIMBLE
Step 2.
WALL THIMBLE COVER
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall thickness
in minimum clearances when figuring venting lengths for
your installation needs.
PIPE LENGTH
Note: Female ends of direct vent pipe/elbows are designed
to slide straight onto the male ends of adjacent pipes by
orienting the pipe indentations so they match and slide into
the entry slots on the male ends, see Figure 5.4. Push
the pipe sections completely together, then twist-lock one
section clockwise approximately one-quarter turn, until the
two sections are fully locked. The female locking lugs may
not be visible from the outside. They may be located by
examining the inside of the female ends.
Type B - Straight Out Installation
TERMINATION CAP
CENTER LINE
16-5/8 in.
(42 cm)
WALL THIMBLE
Female Locking Lugs
WALL THIMBLE COVER
Type C - 45° Elbow in Corner Installation
Male Locking Lugs
WALL THIMBLE
Figure 5.4
45°
ELBOW
2 in. (51mm) CLEARANCE FROM
STOVE CORNER TO
COMBUSTILE WALL
WARNING
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
2 in. (51mm) CLEARANCE FROM STOVE CORNER TO COMBUSTIBLE
WALL
•
•
Maintain all clearances to combustibles.
Figure 5.3
Do NOT allow vent to sag below connection
point to appliance.
• Maintain specified slope (if required).
Step 1.
Improper support may allow vent to sag or separate.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.
Page 12
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 3.
Step 4.
For installations using a round support box/wall thimble Position the horizontal termination cap in the center of the 10
(check pipe manufacturer's instructions), mark the wall for a in. x 10 in. (254mm x 254mm) square hole and run a bead
10 in. x 10 in. (254mm x 254mm) square hole. The center of non-hardening mastic around its outside edges, so as to
of the square hole should line up with the center line of the make a seal between it and the wall, attach termination cap
horizontal pipe, as shown in Figure 5.5. Cut and frame the to the exterior wall with the four wood screws provided. The
hole in the exterior wall where the vent will be terminated. If arrow on the vent cap should be pointing up (Figure 5.6).
the wall being penetrated is constructed of noncombustible
material, i.e. masonry block or concrete, a 7 in. (178mm)
diameter hole is acceptable.
WOOD
SCREW
CENTER OF
HOLE
HOT
CENTER
LINE
WALL THIMBLE
CENTER LINE
WALL
THIMBLE
Figure 5.6
NOTES:
(1) The four wood screws provided should be replaced with
appropriate fasteners for stucco, brick, concrete, or
other types of sidings.
Figure 5.5
(2) A termination cap with a built-in vinyl siding standoff is
highly recommended on a building with vinyl siding. The
pilot hole will be 2 in. (51mm) closer to the bottom of the
square than the top. Using a framing square, draw a 14
in. x 14 in. (356mm x 356mm) square around the pilot
hole in the siding. See Figure 5.7.
NOTE:
(1) Installation requires a minimum of 6 in. (152mm)
horizontalrunofventwitha1/4in. (6mm)riseruntowards
the termination. Each 1 ft. (305mm) of horizontal venting
must include a 1/4 in. (6mm) rise. Never allow the vent
to run downward. This could cause high temperatures
and may present the possibility of a fire.
(2) The location of the horizontal vent termination on an
exterior wall must meet all local and national building
codes, and must not be easily blocked or obstructed,
see Figure 4.4 on page 9.
8 in.
(203mm)
7 in.
(178mm)
7 in.
(178mm)
6 in.
(3) For installations requiring a vertical rise on the exterior
of the building, a snorkel kit is available with a 14 in.
(356mm) and a 36 in. (914mm) tall snorkel termination
cap. Follow the same installation procedures as used
for standard horizontal terminations. If the snorkel
termination must be installed below grade (i.e. basement
application), proper drainage must be provided to
prevent water from entering the snorkel termination. Do
not backfill around snorkel termination.
(152mm)
Figure 5.7
Page 13
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
(NOTE: Some termination caps may cause the vent Note: The attachment from the vent pipe to the vent
pipe to be off center on flashing). Ensure that proper termination cap must be sealed with silicone. Termination
clearances to combustible materials are maintained. caps shall not be recessed into a wall or siding.
If you are not using an approved termination cap with
a built-in standoff on a building with vinyl siding, a
vinyl siding standoff should be installed between the
termination cap and the exterior wall (Figure 5.8). Follow
WARNING
manufacturer’s instructions for attaching the vinyl siding
standoff to the horizontal termination cap. The vinyl
siding standoff prevents excessive heat from possibly
melting the vinyl siding material. The vent terminal cap
shall not be recessed into a wall or siding. Remove
siding from the area where the standoff will be located.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
•
•
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.
VINYL SIDING
WARNING
Apply sealant to all four sides
SCREWS
Do NOT connect a pipe section to a termination cap without
using the telescoping flue section found on the termination cap.
Bolt horizontal top to vinyl
standoff
WARNING
Burn Risk.
•
SCREWS
WALL THIMBLE COVER
Local codes may require installation of a cap
shield to prevent anything or anyone from
touching the hot cap.
Vinyl siding standoff with siding beneath
removed
WALL THIMBLE
Figure 5.8
Step 5.
Place the wall thimble cover over the pipe assembly and
slide the appliance and vent assembly towards the wall,
carefully inserting the vent pipe into the vent termination
cap assembly. It is important that the vent pipe extend into
the vent termination cap a sufficient distance so as to result
in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the
connection between the vent pipe and the vent termination
cap by attaching the two sheet metal strips extending from
the vent termination cap assembly into the outer wall of
the vent pipe. Use the two sheet metal screws provided to
connect the strips to the pipe section (Figure 5.9).
1/4 in. (6mm)
Fold Strap Here
Sheet Metal Screw
Wall Thimble
Wall Thimble Cover/Ceiling
Firestop as Required by Local
Jurisdiction
Strap
Figure 5.9
Page 14
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
G. Vertical Termination
1. Direct Vent Pipe
VERTICAL
TERMINATION
CAP
STORM
COLLAR
25 ft. (8m)
MAXIMUM
FLASHING
FIRESTOP
SUPPORT BOX
PIPE LENGTH
Figure 5.11
Step 2.
Set the gas appliance in its desired location. Drop a plumb
bob down from the ceiling to the position of the appliance
flue exit, and mark the location where the vent will penetrate
the ceiling. Drill a small hole at this point. Next, drop a plumb
bob from the roof to the hole previously drilled in the ceiling,
and mark the spot where the vent will penetrate the roof.
Determine if ceiling joists, roof rafters, or other framing will
obstruct the venting system. You may wish to relocate the
appliance, or to offset, as shown in Figure 5.12 to avoid
cutting loadbearing members.
Figure 5.10
Step 1.
Check the installation instructions for required 1 in. (25mm)
clearances (air space) to combustibles when passing
through ceilings, walls, roofs, enclosures, attic rafters, or
other nearby combustible surfaces. See page 17, Figure
5.16. Check the instructions below for maximum vertical rise
of the venting system, and any maximum horizontal offset
limitations. All offsets must fall within the set parameters of
the vent graph (Figure 5.2) located on page 11.
Plumber’s Tape
connected to
Wall Strap
NOTE: Maximum vertical rise allowable is 25 ft. (8m),
Figure 5.11.
Wall Strap
NOTE: Maximum number of 45° elbows permitted for a
vertical installation is eight, provided their installation
does not decrease maximum allowable horizontal run (as
specified by vent graph, on page 11).
Two 45˚ Elbows
WARNING
Fire Risk.
Explosion Risk.
Figure 5.12
Maintain vent clearance to combustibles as speci-
fied.
• Do not pack air space with insulation or other
materials.
Failure to keep insulation or other materials away
from vent pipe may cause fire.
Page 15
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 3.
To install the round support box/wall thimble cover in a flat
ceiling, cut a 10 in. (254mm) square hole in the ceiling,
centered on the hole drilled in Step 2. Frame the hole as
shown in Figure 5.13.
CAP AND STORM
COLLAR NOT SHOWN
FOR CLARITY
Shingles overlap on
top edge of flashing
Ceiling
Joists
Framing
Figure 5.14
Step 7.
Continue to assemble pipe sections until the height of the
vent (before adding the termination cap) meets the minimum
code requirements as outlined in the current CAN/CGA-B149
Installation Codes (in Canada), the National Fuel Gas Code
NFPA 54/ANSI Z223.1 (in USA), or local codes. Note that
for steep roof pitches, the vent height must be increased.
See roof pitch table (Figure 4.3, on page 8). In high wind
conditions, nearby trees adjoining rooflines, steep pitched
roofs, and other similar factors can result in poor draft, or
down drafting. In these cases increasing the vent height or
switching to the high wind termination cap may solve this
problem.
1 - 1/2 in. (38mm) Long
Wood Screws
Figure 5.13
Step 4.
Assemble the desired lengths of pipe and elbows necessary
to reach from the appliance up through the round support
box. Ensure that all pipe and elbow connections are in their
fully twist-locked position. Assemble as instructed.
Step 5.
Cut a hole in the roof centered on the small drill hole placed in
the roof in Step 2. The hole should be of sufficient size to meet
the minimum requirements for clearance to combustibles, as
specified. Continue to assemble lengths of pipe and elbows
necessary to reach from the ceiling support box/wall thimble
up through the roof line. Galvanized pipe and elbows may
be utilized in the attic, as well as above the roofline. The
galvanized finish is desirable above the roofline, due to its
higher corrosion resistance.
Step 8.
Slip the storm collar over the pipe, and push it down to the
top of the flashing (Figure 5.15). Use non-hardening sealant
above and below the joint between the storm collar and the
pipe.
Optional High Wind Termination Cap
Secure Flashing with Non-Hardening
Sealant and Roofing Nails
NOTE:
(1) If an offset is necessary in the attic to avoid obstructions,
it is important to support the vent pipe every 3 ft.
(914mm) to avoid excessive stress on the elbows, and
possible separation. Wall straps are available for this
purpose, Figure 5.12, page 15.
(2) Whenever possible, use 45° elbows, instead of 90°
elbows. The 45° elbow offers less restriction to the flow
of flue gases and intake air.
Step 6.
Figure 5.15
Slip the flashing over the pipe section(s) protruding through
the roof. Secure the base of the flashing to the roof with
roofing nails. Ensure the roofing material overlaps the top
edge of the flashing as shown in Figure 5.14. Verify that the
chimney is the required height above the roof. See roof pitch
table, Figure 4.3, on page 8.
Page 16
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 9.
Twist-lock the vent cap and seal.
Note: For multi-story vertical installations, a ceiling firestop
is required at the second floor, and any subsequent floors
(Figure 5.16). The opening should be framed to 10 in. x
10 in. (254mm x 254mm) inside dimensions, in the same
manner as shown in Figure 5.13 on page 16.
NAILS
CEILING FIRES TOP
MIN. 1 in. (25mm)
CLEARANCE
MIN. 1 in. (25mm)
CLEARANCE
MIN. 1 in. (25mm)
CLEARANCE
MIN. 1 in. (25mm)
CLEARANCE
Figure 5.16
WARNING
Fire Risk.
Explosion Risk.
• Any occupied areas above the first floor, including
closets and storage spaces, which the vertical
vent passed through must be enclosed. The
enclosure may be framed and sheetrocked with
standard construction materials; however, refer
to these installation instructions for the minimum
allowable clearance between the outside of the
vent pipe and the combustible surfaces of the
enclosure. Do not fill any of the required air space
with insulation.
Page 17
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Cathedral Ceiling
Step 1.
Follow installation Steps 1 and 2 under vertical installation
section, page 15.
Step 2.
Remove shingles or other roof covering as necessary to cut
the rectangular hole for the support box. Cut the hole 1/8 in.
(3mm) larger than the support box outline.
Step 3.
Lower the support box through the hole in the roof until the
bottom of the support box protrudes at least 2 in. (51mm)
below the ceiling (Figure 5.17). Align the support box both
vertically and horizontally with a level. Temporarily tack the
support box in place through the inside walls and into the
roof sheathing.
Figure 5.18
Step 6.
Level
Place the support clamp (provided with the support box)
inside the support box (at the bottom), and secure to the pipe
section. The clamp allows the support box to support the
weight of the pipe sections. Continue to add pipe sections
until you are above the roofline.
Cathedral Ceiling
Support Box
Step 7.
Complete the cathedral ceiling installation by following the
same procedures outlined in steps 7 through 9 for vertical
installations, pages 16-17.
2 in. (51mm)
Min. below
finished ceiling
Step 8.
Cut hole 1/8 in. (3mm)
greater in size than
pattern of support box
as it is projected onto
roof line
Install the black trim collar around the outside of the cathedral
ceiling support box (Figure 5.19). The two pieces of the trim
collar slide over one another to allow for easy adjustment
around the support box. Using the six screws provided,
secure the four corners and the overlapping sections of the
trim collar to the ceiling. You may want to predrill the holes for
the overlapped sections for ease of installation.
Figure 5.17
Step 4.
Using tin snips, cut the support box from the top corners
down to the roofline, and fold the resulting flaps over the
roof sheathing (Figure 5.18). Before nailing it to the roof,
run a bead of non-hardening mastic around the top edges
of the support box to make a seal between it and the roof.
Clean out any combustible material from inside the support
box.
Trim Collar
Step 5.
Assemble the desired lengths of pipe and elbows necessary
to reach from the appliance up through the round support
box. Ensure that all pipe and elbow connections are in their
fully twist-locked position. Assemble as instructed.
Cathedral
Ceiling
Support
Box
Screws
Figure 5.19
Page 18
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Class A Metal Chimney
Step 4.
Pass the flex pipe down through the center of the chimney
system, and center the top adapter on the top of the chimney
pipe. Drill four 1/8 in. (3mm) diameter holes through the
top adapter, and into the chimney top. Ensure that you are
drilling into the metal on the chimney. Twist lock the high
wind termination cap onto the top adapter (Figures 5.22
and 5.23).
TERMINATION
CAP
TOP
ADAPTOR
FLASHING
EXISTING
METAL
CHIMNEY
SYSTEM
4 in. (102mm)
FLEX PIPE
RETRO CONNECTOR
DIRECT VENT PIPE
Figure 5.22
Figure 5.20
High Wind Termination
Cap
CAUTION
Ensure that existing chimney is functionally sound and clean.
•
Have inspection done by qualified chimney sweep or
professional installer BEFORE converting to direct vent
appliance.
Sheet Metal Screws
Step 1.
Drill Four 1/8 in.
(3mm) Diamater
Holes
Remove existing chimney cap.
Step 2.
Measure the distance from the top of the chimney to the
bottom of the ceiling support box, add 3 in. (76mm) to this
measurement, and cut a section of 4 in. (101mm) flex pipe to
that length (the flex should be fully extended).
Figure 5.23
Step 3.
Connect the end of the flex pipe section to the underside
of the top adapter, using four sheet metal screws (Figure
5.21).
Step 5.
Pull the flex pipe down through the ceiling support box, until
it protrudes approximately 3 in. (76mm). Connect the flex
pipe to the retro connector, and attach with sheet metal
screws.
Top Adapter
Step 6.
Push the flex pipe back up into the ceiling support box,
center the retro connector, and attach it to the support box
with sheet metal screws.
Flex Pipe
Sheet Metal Screws
Step 7.
The connection between the appliance and the retro
connector may be completed with sections of direct vent
pipe.
Figure 5.21
Page 19
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Existing Masonry Chimney
Type A & B Co-Axial to Co-Linear
CHIMNEY LINER
TERMINATION
CAP
CHIMNEY LINER
TERMINATION CAP
25 ft. (8m) OF 3 in.
(76mm) FLEX
LINER EXHAUST
SECTION
3 in. (76mm)
FLEX LINER
THIS SECTION OF
THE CHIMNEY MUST
BE SEALED
CO-AXIAL TO
CO-LINEAR
CO-AXIAL TO
CO-LINEAR
CONNECTOR
CONNECTOR
THE CHIMNEY MUST BE
SEALED FROM THE 4 ft. (1m)
SECTION TO TERMINATION
USING A SMOKE SHELF OR A
DAMPER. THE SEAL SHOULD
BE 6 in. (152mm) BELOW THE
END OF THE 4 ft. (1m) AIR
INTAKE SECTION.
PIPE LENGTH
OPTIONAL
PIPE LENGTH
OPTIONAL
SHOWING TWO
25 ft. (8m)
SECTIONS OF
FLEX LINER
4 ft. (1m) OF 3 in.
(152mm) FLEX LINER
AIR INTAKE SECTION
Type D - Hearth Mount
Type C - Up & Out Installation
TERMINATION
CAP
CHIMNEY LINER
TERMINATION CAP
TOP ADAPTOR
FLASHING
25 ft. (8m) OF 3 in.
(76mm) FLEX LINER
THIS SECTION OF THE
CHIMNEY MUST BE
SEALED
ALCOVE CLEARANCE
TO COMBUSTIBLES
MUST BE MAINTAINED.
4 in. (1m) FLEX
LINER
RETRO
CONNECTOR
CHIMNEY MUST BE SEALED
FROM 4 ft. (1m) SECTION TO
TERMINIATION USING A
SMOKE SHELF OR A
90 DEGREE
ELBOW
DAMPER*. SEAL SHOULD BE
6 in. (152mm) BELOW END OF
4 ft. (1m) AIR INTAKE
SECTION.
DIRECT
VENT PIPE
4 ft. (1m) OF 3 in. (76mm)
FLEX LINER AIR INTAKE
SECTION
CO-AXIAL TO CO-LINEAR
CONNECTOR
*In the Commonwealth of Massachusetts, the word damper shall be
replaced with the words flue restrictor.
Figure 5.24
Page 20
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION
Cut and bend flashing as needed
to fit
Ensure that existing chimney is functionally sound and clean.
•
Have inspection done by qualified chimney sweep or
professional installer BEFORE converting to direct vent
appliance.
Step 1.
Before cutting any holes, assemble the desired sections
of direct vent pipe to determine the center of the masonry
penetration.
Sealant adhesive
Figure 5.26
Step 2.
Once the center point of the penetration has been determined,
cut a 6 in. (152mm) diameter hole in the masonry. If the hole
is too large, the retro connector might not mount properly; if
the hole is too small, the appliance might starve for intake
air. If there is a frame wall in front of the masonry wall, cut
and frame a 10 in. (254mm) square opening in the wall
(centered around the 6 in. (152mm) masonry opening). If
there is sheet rock only (no studs) in front of the masonry the
10 in. (254mm) opening is still needed, but does not need
to be framed. If the hole is framed a round support box/wall
thimble is required. This allows the retro connector to mount
directly on the masonry and provide the correct clearances to
combustibles (Figure 5.25).
Step 4.
To determine the length of flex needed, measure from 3 in.
(76mm) above the top of the flashing down to the level of the
opening. Add the distance from the center of the chimney
out through the wall. Cut a piece of 4 in. (102mm) flex to this
length (extended to its nominal length). Be sure to leave 2-3
in. (51-76mm) of flex above the existing chimney to allow for
connection to the termination kit.
Step 5.
Connect the flex liner to the top adapter using three sheet
metal screws (Figure 5.21 page 19).
Step 6.
Studwall
Feed the flex liner through the flashing into the chimney.
Carefully feed the flex liner down the chimney to the bottom
and out the opening in the masonry wall, forming an angle to
line up the flex liner with the vent opening on the appliance.
10 in. x 10 in. (254mm x 254mm)
Masonry
Chimney
framed opening in wall
Retro Connector
WARNING
Fire Risk.
Wall Thimble Cover
Explosion Risk.
(4) Masonry Bolts
(Not Included)
•
Do not let the flex liner sag below the level at
which it will connect to the appliance or connector.
This could allow hot gas to become trapped and
potentially become a fire hazard. The flex liner path
should always be sloped up toward the termination
cap.
NOTE: For hearth applications refer to page 19, Figure 5.24 for
the use of a co-axial to co-linear appliance connector.
Figure 5.25
Step 3.
Secure the flashing to the top of the masonry chimney using
a bead of non-hardening sealant-adhesive. If the flashing is
larger than the top of the chimney, cut and fold flashing as
needed to fit chimney (Figure 5.26).
Step 7.
If additional lengths of flex liner are needed to span the
chimney height, use a flex coupler to connect the pieces of
flex liner together. Connect the flex to the coupler by using
four sheet metal screws for each side (Figure 5.27, on the
next page).
Page 21
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Flex Liner
6 in. (152mm) diameter
opening in masonry wall
Flex Coupler
Sheet Metal Screws
Retro Connector
(3) Masonry Bolts
(Not included)
Figure 5.27
Figure 5.29
Step 8.
Secure the top adapter to the flashing. Use three sheet
metal screws through the side of the top adapter into the
flange on the flashing (Figure 5.28). Twist lock the high
wind termination cap on to the top adapter.
Step 10.
Slide wall thimble cover over retro connector and secure
with masonry bolts (Figure 5.30). If you have a framed wall
in front of the masonry, use wood screws to mount wall
thimble cover to framed wall, over retro connector and 10
in. (254mm) square framed opening (Figure 5.25, page
21). If needed, add a section of direct vent pipe to the retro
connector in order to extend through the opening in the wall
thimble cover.
High Wind
Termination Cap
Top Adaptor
(3) Sheet Metal Screws
Retro Connector
Wall Thimble Cover
Flashing
(4) Masonry Bolts
(Not included)
Figure 5.28
Figure 5.30
Step 9.
Attach the flex to the retro connector. Use three sheet metal
screws to attach the flex liner to the connector (Figure
5.29). Mount the retro connector to the masonry wall using
masonry bolts. Redrill larger holes on connector as needed.
Be careful to ensure that the connector is centered in the
opening and the mounting holes line up with the masonry
wall.
Step 11.
The connection between the appliance and the retro
connector may be completed with sections of direct vent
pipe.
Page 22
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
H. Slim Line Wall Thimble
BEFORE YOU BEGIN:
Review the venting configurations in Figures A, B and C on
the next page.
1. Assembling Slim Line Trim Ring and Heat Shield
Figure 5.33 Attach the heat shield to the trim ring with the four
screws provided. Screws go through the heat shield and into
the brackets on the trim ring.
2. Installing Slim Line Trim Ring and Heat Shield
Measure from the floor to the center of the vent pipe. Cut out
a 9-1/2 in. (241mm) hole in the wall. Hold the trim ring/heat
shield assembly in place and put a mark on the shield with
a black marker where it protrudes through the exterior wall.
See Figure A on the next page.
Figure 5.31 Lay the trim ring on flat surface and bend up the
six welded brackets into a 90 degree position. The brackets
along the outer edge of the ring are for locating the ring in
the center of the hole.
Use that mark as a guide to trim off excess heat shield with
a pair of sheet metal shears.
3/4
3/4
3/4
Figure 5.34 When installing the trim ring/heat shield assem-
bly make sure the trim ring is centered in the hole and that
the shield is above the pipe. There must be a minimum of
3/4 in. (19mm) minimum clearance maintained to combus-
tibles from the top of the heat shield.
Figure 5.32 The heat shield is shipped flat and must be hand
bent into a half circle before attaching it to the trim ring. Bend
the heat shield as shown.
NOTE: Wear leather gloves when bending the heat shield to
prevent injury.
Ensure that framing on the inside of the wall is a mini-
mum inner framing diameter of 10 in. x 10. in. (254mm x
254mm).
CAUTION
Sharp Edges
The four trim ring mounting screws provided should be
replaced with appropriate fasteners for stucco, brick, con-
crete, or other types of sidings.
•
Wear protective gloves
and safety glasses during
installation.
Page 23
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
FIG. A 90 DEGREE ELBOW
PLACE MARK WHERE PROTRUDES THROUGH
EXTERIOR WALL TO CUT OFF EXCESS
90° ELBOW
CENTER LINE
TERMINATION CAP
HEAT SHIELD
OVER PIPE
PIPE LENGTH
TRIM RING
PIPE LENGTH
FIG. B 45 DEGREE ELBOW
TRIM RING
HEAT SHIELD OR WALL
THIMBLE OVER PIPE
45°
ELBOW
2 in. (51mm) CLEARANCE FROM
STOVE CORNER TO COMBUSTILE
WALL
2 in. (51mm) CLEARANCE FROM STOVE CORNER TO COMBUSTIBLE
WALL
FIG. C MINIMUM CLEARANCE
MINIMUM OF 6 in. (152mm) OF PIPE
THROUGH THE WALL
INTERIOR WALL (2 in. (51mm)
clearance from rear of stove)
WALL THIMBLE
CENTER LINE
TERMINATON CAP
HEAT SHIELD OVER TOP HALF
OF PIPE
TRIM RING
Figure 5.34
Page 24
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Information
6
PILOT HOOD
A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
MILLIVOT GENERATOR
THERMOCOUPLE
ALIGNMENT NOTCH
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a qualified
technician using Hearth & Home Technologies specified and
approved parts.
Figure 6.2 Pull off pilot hood and set aside. Do not remove
the wire clip.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed by a
qualified service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must
be performed by a licensed plumber or gas fitter.
5/32 in. Allen
wrench
Anydamagedvalvecomponentsshouldnotbeinstalled.
If a valve or regulator has been dropped or appears to
have been modified, the valve or regulator should not
be installed.
Figure 6.3 Use a 5/32 in. Allen wrench to remove the pilot
injector. Replace pilot injector with the one supplied with the
appliance (#35 for Propane, #62 for Natural Gas).
KIT CONTENTS: Replacement orifice; replacement
pilot injector; valve regulator; and conversion label.
Replace pilot hood, snapping into position.
TOOLS REQUIRED: #2 Phillips head screwdriver, slot-
ted screwdriver or Torx TH20; 5/32 in. Allen wrench; 3/8
in. open end wrench.
Remove 2 screws
Figure 6.4 Remove main burner orifice using a 3/8 in. wrench.
Be sure to align notch on left side of pilot hood, shown.
Replace orifice with the proper size as indicated below for
your gas type and venting.
Figure 6.1 Remove top and front (if installed), glass, and
logs (if installed). Remove burner by removing ONLY the
two screws indicated. DO NOT remove the screws from the
burner top. Lift the burner up and out of the firebox.
PROPANE
NATURAL GAS
#56
#49
Reinstall burner.
Page 25
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Valve Regulator Replacement
Screws
E
WARNING
Fire Risk.
Explosion Risk.
D
•
Disconnect any electrical cords and
turn off gas supply to unit before
proceeding if converting fuel on an
appliance already fully installed.
Rubber Gasket
F
Identification Label
Remove upper and lower back shield. Loosen the set col-
lars on the extension rods with the 3/32 in. Allen wrench.
Remove the rods and adapter cap.
Figure 6.6 Ensure that the rubber gasket (D) is properly posi-
tioned and install the new HI/LO pressure regulator assem-
bly to the valve using the new screws (E) supplied with the
kit. Tighten screws securely. (Reference torque = 25 in./lb.)
Install the enclosed identification label (F) to the valve body
where it can be seen.
A
B
Mounting Screws
Pressure Regulator Tower
C
Diaphragm
Fill out the conversion label and attach it to the valve cover.
WARNING
Fire Risk.
Explosion Risk.
Gas Leak Risk.
•
Rubber gasket must be seated properly on valve
face.
•
Do no install a valve or regulator that has been
dropped.
Figure 6.5 Turn control knob to the OFF position, ensure that
gas supply to the valve has been turned off. Using a Torx
TH20, or slotted screwdriver, remove the three pressure reg-
ulator mounting screws (A), pressure regulator tower (B),
and diaphragm (C).
WARNING
Fire Risk.
Explosion Risk.
•
If the information in these instructions is
not followed exactly, a fire, explosion or
production of carbon monoxide may result
causing property damage, personal injury
or loss of life.
•
The qualified service agency is responsible
for the proper installation of this conversion
kit. The installation is not proper and
complete until the operation of the converted
appliance is checked as specified in the
manufacturer’s instructions supplied with
the kit.
Page 26
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Gas Pressures
C. Gas Connection
Proper input pressures required for optimum appliance per-
formance, gas line sizing requirements need to be followed
from NFPA51.
NOTE: Have the gas supply line installed in accordance with
local building codes, if any. If not, followANSI Z223.1. Instal-
lation should be done by a qualified installer approved and/or
licensed as required by the locality. (In the Commonwealth of
Massachusetts, installation must be performed by a licensed
plumber or gas fitter.)
WARNING
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
NOTE: A listed (and Commonwealth of Massachusetts
approved) 1/2 inch (13mm) T-handle manual shut-off valve and
flexible gas connector are connected to the 1/2 inch (13mm)
control valve inlet.
•
Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
•
Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
•
If substituting for these components, please consult
local codes for compliance.
WARNING
WARNING
Verify inlet pressures.
Gas Leak Risk.
•
•
•
High pressure may cause overfire condition.
Low pressure may cause explosion.
Verify minimum pressures when other household
gas appliances are operating.
•
Support control when attaching pipe to
prevent bending gas line.
Install regulator upstream of valve if line pressure is
greater than 1/2 psig.
NOTE: The gap between the supply piping and gas access
hole may be plugged with non-combustible insulation to prevent
cold air infiltration.
Pressure requirements for appliance are shown in the table
below. Minimum pressures must be met when other house-
hold gas appliances are operating.
Leak test all gas line joints and the gas control valve prior
to and after starting the appliance.
PRESSURE
NG
LP
Before making the gas connection, ensure that the appliance
you are installing is designed for the type of gas being
supplied. This information can be found on the ratings label
under the appliance. If the appliance has been converted
to propane (LP), the valve cover should have a label stating
that the appliance has been converted to propane.
Minimum Inlet Pressure
Maximum Inlet Pressure
5 inches w.c.
10 inches w.c.
11 inches w.c.
13 inches w.c.
10 inches w.c.
Manifold Pressure on “HI” 3.5 inches w.c.
If the pressure is not sufficient, ensure:
Connect the gas line at the 3/8 in. (10mm) pipe connector
on the valve at the back of appliance. We recommend
connecting the appliance with an approved flex gas line.
If flex gas lines are not approved in your area, you must
connect a hard pipe to the gas hookup.
1) the piping used is large enough.
2) the supply regulator is adequately adjusted.
3) that the total gas load for the residence does not exceed
the amount supplied.
You must supply a manual shut-off valve in a visible location
within 3 ft. (914mm) of the appliance.
The supply regulator (the regulator that attaches directly to the
residence inlet or to the propane tank) should supply gas at
the suggested input pressure listed above. Contact the local
gas supplier if the regulator is at an improper pressure.
Page 27
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
HIGH ALTITUDE INSTALLATIONS
WARNING
Omni-Test Laboratories, Inc. listed gas appliances are tested and
approved without requiring changes for elevations from 0 to 2000
feet in the U.S.A. and 0 to 4500 feet in Canada.
Fire Risk or Explosion Hazard.
•
•
Gas build-up during line purge may ignite.
Purge should be performed by a qualified
technician.
Ensure adequate ventilation.
Ensure there are no ignition sources such
as sparks or open flame.
When installing this appliance at an elevation above 2000 feet,
it may be necessary to decrease the input rating by changing
the existing burner orifice to a smaller size. Input rate should be
reduced by 4% for each 1000 feet above a 2000 foot elevation
in the U.S.A. If the heating value of the gas has been reduced,
these rules do not apply. To identify the proper orifice size, check
with the local gas utility.
•
•
A small amount of air will be in the gas supply lines. When
first lighting appliance it will take a short time for air to
purge from lines. When purging is complete the appliance
will light and operate normally.
•
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
Air only needs to be purged again if gas valve has been
turned to the OFF position.
WARNING
CHECK FOR GAS LEAKS
Explosion Risk.
Fire Risk.
Asphyxiation Risk.
•
•
•
Check the fittings and connections
Do not use open flame.
After the gas line installation is complete, all
connections must be tightened and checked
for leaks with a commercially-available, non-
corrosive leak check solution. Be sure to rinse
off all leak check solution following testing.
Fittings and connections may have loosened during
shipping and handling.
WARNING
Fire hazard.
Do NOT change the valve settings.
•
•
This valve has been preset at the factory.
Changing valve settings may result in fire
hazard or bodily injury.
Page 28
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Information
7
A. Recommendation for Wire
8. Ensure the thermostat is mounted level for accurate
readings.
See B5 below for recommended maximum lead length (two
wire) when using wall thermostat/switch.
9. The thermostat should be mounted on an inside wall
and not in direct line with the appliance convection air.
NOTE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code, CSA
C221.1.
10. If the thermostat is located too close to the appliance,
you may need to set the temperature setting slightly
higher to maintain the desired temperature in your
home.
Do not connect this appliance to a thermostat serving
any other appliance.
B. Connecting to the Appliance
Bedroom installation in Canada requires this appliance
to be connected to a thermostat.
WARNING
Wire 110v to electrical junction box.
Do NOT wire 110v to the valve.
Do NOT wire 110V to wall switch.
WARNING
•
Incorrect wiring will damage millivolt
systems.
Shock hazard.
•
This appliaance is eqquuipped witth a three
prongged (grrounddiing) pllug forr your pprotection
againnst shhoock hazzard aand shoould bbe plugged
directlyy into a prroperly grounded three prong
receptacle. Do not cut or remove the grounding
prong from this plug.
1. This appliance may be used with a wall switch, wall
mounted thermostat and / or a remote control.
2. If using thermostat, use one compatible with a millivolt
gas valve system.
C. Standing Pilot Ignition System Wiring
This appliance DOES NOT require 110 VAC supply for
operation. A wiring diagram is shown in Figure 7.1 on the
next page.
3. Follow parameters for locating thermostat (see individ-
ual thermostat instructions) to ensure proper operation
of appliance.
This appliance is equipped with a millivolt control valve.
4. Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
5. Use the following chart for wire sizing.
Wire Size
16 gauge
18 gauge
20 gauge
22 gauge
Max. Length
65 feet
40 feet
25 feet
18 feet
6. Keep wire lengths as short as possible by removing
any excess wire length.
7. Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
Page 29
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
PILOT ASSEMBLY
Ignition Module
TPTH
TP
Black
E
A
ON/OFF
F
F
O
Switch
T
P
O L I
P
L
I
T
O
Black
TH
VALVE
Figure 7.1
CAUTION
CAUTION
Shock hazard.
•
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Replace damaged wire with type 105O C
rated wire.
Wire must have high temperature insulation.
•
D. Ignition Module Access and Battery
Replacement
The Ignition Module is located under the appliance attached
to the decorative cover.
To access the module:
1. Lift off the appliance top and place it on a flat surface,
with the porcelain side up to prevent damage.
2. Remove the appliance front by sliding it upwards in the
grooves, being careful not to chip the porcelain. Lay the
front face up on a flat surface.
3. With the cast iron front removed, remove the decorative
cover located under the apliance. To remove the cover,
remove the two screws on the front of the appliance that
hold the cover in place. Pull the cover forward, down
and out. The module will then be accessible for service
and battery replacement.
Figure 7.2
CAUTION
Battery polarity must be correct or module damage will occur.
The single "AA" 1.5V battery that powers the ignitor is
located in the module. To replace the battery, open the
battery compartment and remove the old battery. Replace
the battery making sure the polarity is correct.
Page 30
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance Setup
8
A. Remove Shipping Materials
C. Flue Restrictor Installation
Remove shipping materials from inside or underneath the
firebox.
When your installation falls within a shaded area on the vent
graph (page 11), a flue restrictor must be installed for proper
operation.
B. Leg Leveling System
Figure 8.1 Thread Allen bolts through nuts until flush. The
Allen bolts and nuts are included in the component pack inside
the appliance firebox.
Figure 8.4 Installation of the flue restrictor requires the removal
of the baffle located inside the firebox. Remove the baffle
by first removing the two screws holding the baffle in place
(one on each side).
Lift the baffle out of the bracket along the back of the firebox,
angle the baffle slightly and remove it from the firebox.
Figure 8.2 Slide assembled nuts and bolts into the slots on
the legs with the nuts on the bottom.
Figure 8.5 With the baffle removed, remove the two screws
located in the back of the firebox. Reuse the screws to install
the flue restrictor. Reinstall the baffle using the two screws
previously removed.
Figure 8.3 Use a 5/32 in. 4mm) Allen wrench to adjust legs
up and down to desired level.
The flue restrictor should be used in all situations that fall
within the shaded area on the vent graph.
Page 31
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
D. Intake Damper Operation
F. Positioning the Logs
The intake damper can be used with or without the flue While still breakable, the logs do not become fragile until
restrictor to adjust the air flow. Opening the damper makes after the appliance is burned and they have cured. After
the flames shorter and more active. Closing the damper curing, any handling must be done with care as breakage
makes the flames taller and less active.
can easily occur.
PLEASE NOTE: Logs have been designed to work
specifically with the burner of this appliance. Exact
placement will ensure proper operation of your gas
appliance and reduce sooting.
Figure 8.6 Loosen the wingnut that secures the damper. The
wingnut is located on the underside of the appliance, to the
right of the pilot assembly.
To CLOSE the intake damper, pull the wingnut forward.
To OPEN the damper, push the wingnut back. Adust the
damper in 1/4 in. increments until the desired flame is
achieved. After adjustment, tighten the wingnut.
Figure 8.8 Gently remove the top of the appliance and set
aside. Remove the cast face by sliding straight up and set
it aside.
NOTE: In the Commonwealth of Massachusetts, the word
damper shall be replaced with the words flue restrictor.
Remove the glass by releasing the latch located on the top of
the appliance. Lean the glass frame forward and lift it out.
Place the left log on the log shelf along the back of the firebox
with thefront resting on the burner.
E. Intake Air Shutter Adjustment
OPEN
CLOSE
Figure 8.9 Place the right log on the log shelf along the back
of the firebox with the front of the log resting on the burner.
Figure 8.7 The shutter is located on the underside of the
appliance, on the right side. To adjust the shutter, loosen
the wingnut.
Moving the shutter bolt to the right closes the shutter. Moving
the shutter bolt to the left, will open the shutter. Opening the
shutter causes flames to become shorter and blue. Closing
the shutter creates taller orange/yellow flames.
NOTE: Do not close so much as to cause a sooty flame.
Improper adjustment can cause sooting in the firebox and/
or on the outside of a house with a horizontal termination.
Retighten the wingnut after adjustment.
Page 32
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
H. Accessories
Install approved accessories per instructions included with
accessories. Refer to Section 12 for appropriate accesso-
ries.
WARNING
Shock or fire risk.
Use ONLY optional accessories approved for
this appliance.
Figure 8.10 Place the twig with the center resting on the flat
area in the center of the burner and both ends positioned as
shown.
•
•
•
Using non-listed accessories voids
warranty.
Using non-listed accessories may result in a
safety hazard.
Only Hearth & Home Technologies approved
accessories may be used safely.
G. Mineral Wool
WARNING
Explosion Risk.
•
•
•
Follow ember placement instructions in
manual.
Do NOT place embers directly over
burner ports.
Replace ember material annually.
Improperly placed embers interferes with proper burner
operation.
Figure 8.11
Apply dime size pieces sparingly along front
edge of burner. Do not completely block ports.
Page 33
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
I. Blower Installation
KIT CONTENTS:
1 - Blower Mounted in Housing
2 - Speed Control Knob
3 - Pal Nut
4 - Ceramic Snap Disk
5 - Speed Control (Rheostat)
6 - Wire Harness (attached to Blower)
7 - 12 Screws
8 - 12 inch Glass Tape
9 - 1 Zip Tie
10 - Bracket #1
Figure 8.13 Lift off the appliance top and place it on a flat
surface, with the porcelain side up to prevent damage.
Remove the back shield by removing the two screws along
the top of the shield.
11 - Snap Disc Bracket
TOOLS REQUIRED: Short #2 Philips screwdriver; 11/16"
wrench.
Place the blower on the floor behind the appliance and route
the ends of the wiring harness through the rubber grommet
on the underside.
Figure 8.14
Holding the blower in place, attach it to the
appliance with four of the screws provided.
SNAP DISC
SNAP DISC
BRACKET
11
10
Figure 8.12
Open and inspect contents of the blower kit.
The contents of the kit are listed above. If any of the parts
are missing or damaged, please contact your dealer for
replacements. NOTE: Not all parts will be used for this
install.
SPADE
TERMINALS
Figure 8.15
Install the snap disc. A snap disc bracket is
located in the appliance's component bag. Bend the two
spade teminals on the snap disc from a horizontal to a
vertical position. Insert the snap disc through the hole in the
snap disc bracket and attach the two white wires from the
wiring harness to the snap disc.
NOTE: The mounting flange is on top of the bracket.
Page 34
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Plug in the blower.
The blower will not run until the appliance has heated up
enough to activate the snap disc. This can take up to 15
minutesdependingonthetemperatureoftheroom. Likewise,
the blower will not automatically turn off until the appliance
has cooled off enough to turn off the snap disc.
Turning the control knob to the left (counterclockwise) until
you hear an audible click will turn the blower "OFF". Turning
the control knob to the right (clockwise) until you hear a click
Figure 8.16 With the cast iron front of the appliance removed, will turn the blower "ON". Turning the control knob further to
remove the decorative cover located under the appliance. the right will reduce the speed of the blower.
To remove the cover, remove the two screws on the front
of the appliance that hold the cover in place. Pull the cover
forward, down and out.
Figure 8.17 Attach the snap disc bracket to the stud located
under the left side of the appliance using the 10-32 nut also
located in the appliance component bag.
Figure 8.18 Install the speed control (rheostat). The speed
control mounts to the decorative cover removed in Step 5.
Insert the stem of the speed control through the hole located
on the right side of the cover. Secure with the pal nut using
an 11/16 in. (17.5 mm) wrench. Attach the black and white
wires routed under the appliance indicated in Figure 8.13,
on page 34, to the two speed control wires. Push the speed
control knob onto the stem and re-attach the decorative
cover. Secure the wires up and out of the way using the zip
tie provided.
Page 35
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
VARIABLE SPEED CONTROL
JUNCTION BOX
BLOWER RECEPTACLE
BLACK
BLACK
WHITE
GROUND
TEMPERATURE SENSOR SWITCH
BLOWER
GREEN
BLACK
110 - 120 VAC
POWER SUPPLY
Figure 8.19 Complete Assembly
Page 36
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
J. Warming Shelves Installation
KIT CONTENTS: (2) Warming shelves, (2) brackets, and (4)
1/4 in. Phillip head screws.
TOOLS NEEDED: Phillips head screwdriver.
Figure 8.23 Align bracket to firebox and gently tighten the
screw to hold it in place.
Reassemble the appliance.
K. Glass Replacement
Figure 8.20
Remove warming shelves and hardware from
Turn the appliance OFF and let it cool down before replacing
the glass. Lift off the appliance top and place it on a flat
surface with the porcelain side up to prevent damage.
packaging. Install leveling bolt to each warming shelf.
Remove the appliance front by sliding it upwards in the
grooves being careful not to chip the porcelain. Lay the front
face up on a flat surface.
Unhook the latch now exposed on top of the appliance. Pull
the top of the glass frame toward you and lift it out of the
retainer along the bottom of the firebox.
Replacement is the reverse of the removal.
Figure 8.21 Install warming shelf bracket loosely to each
warming shelf using the bolt provided.
CAUTION
Handle glass assembly with care.
•
•
Inspect the gasket to ensure it is undamaged.
Inspect the glass for cracks, chips or
scratches.
•
•
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with glass door
removed, cracked, broken or scratched.
Replace glass assembly as a complete
assembly.
•
Figure 8.22 Gently lift cast top off of unit and set aside.
Install warming shelf to unit gently aligning the shelf with the
tabs that are in place on the side of the unit. Use the leveling
bolt in the located in the center of the warming shelf to adjust
the shelf to it's desired position.
Page 37
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
9
A. Before Lighting Appliance
WARNING
Read this entire manual prior to using the appliance. Failure
to follow the instructions may result in property damage,
bodily injury, or even death.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
the owner’s information manual provided with this appliance.
For assistance or additional information consult a qualified
installer, service agency or the gas supplier.
•
Remove all shipping materials from inside and/or
underneath the firebox.
•
•
•
•
•
Review proper placement of logs, mineral wool.
Check the wiring.
WARNING
Check the baffle adjustment.
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Ensure that there are no gas leaks.
Ensure that the glass is sealed and in the proper posi-
tion.
•
Ensure that the flow of combustion and ventilation air
is not obstructed (front grilles and vent caps).
B. Controls
FAN SPEED: The blower is optional installed on the
appliance and this knob controls the speed of the blower
that pushes the heated air into the room.
WARNING
Glass door must be in place when appliance is
operating.
Risk of:
MAIN BURNER: This control is used to turn the appliance
on and off.
•
•
Combustion Fumes
Fire
Do NOT operate appliance with glass door
removed.
PILOT IGNITOR: The pilot ignitor is used only to start the
pilot. When the valve control knob is turned to the pilot
position and fully depressed, it sends an electrical charge
to the pilot assembly. The appliance is equipped with an
electric igniter and should begin sparking right away.
•
•
Open viewing glass for servicing only.
Glass door MUST be in place and sealed before
operating appliance.
Only use glass door certified for use with appliance.
Glass replacement should be done by qualified
technician.
•
•
VALVE CONTROL: This knob is used to control gas to the
appliance and for starting the pilot. There are three positions,
ON, OFF, & PILOT. The indicator on the valve indicates the
position of the knob.
WARNING
COMFORT CONTROL: This knob controls the flame height
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
from low (“LO”) to high (“HI”).
NOTE: If using a remote control wall switch, or thermostat,
the On/Off Switch must be left “OFF”. Turning the On/Off
Switch to “ON” will keep the appliance on continually.
Glass and other surfaces are hot
during operation and cool down.
•
Keep children away.
•
CAREFULLY SUPERVISE children in same room as
appliance.
•
•
•
Alert children and adults to hazards of high temperatures.
Do NOT operate with protective barriers open or removed.
Keep clothing, furniture, draperies and other combustibles
away.
Page 38
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
C. Lighting Appliance
FOR YOUR SAAFETY REAADD BEFORE LLIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life
A. This appliance has a pilot that must be lit manually. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch, do not use any phone in your building.
* Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
* If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't
try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Set the thermostat to the lowest setting (if applicable) and turn off
the switch at the control panel.
3. Disconnect the power from the appliance.
4. Open the door of the appliance. May need to remove face/front first.
5. Push in gas control knob slightly and turn clockwise
position. Do not force.
to the "OFF"
6. Wait five (5) minutes to clear out any gas. Smell for gas, including near the floor. If you smell gas, STOP! Follow "B" of the
safety information above. If you don't smell gas go to the next step.
7. Push gas control knob in and turn counterclockwise
pushed in slightly. Do not force.
to the pilot position. NOTE: Knob cannot be turned unless knob is
8. PIEZO IGNITER: Press down on the gas control knob in pilot position and simultaneously press the piezo igniter.
(This may take many repetitions for lighting.)
ELECTRONIC IGNITER: If the unit is equipped with an electronic igniter it should begin sparking right away.
9. The pilot should be visible through the door opening.
10. After the pilot is lit, continue holding control knob down for approximately
PILOT HOOD
30 seconds. Release the knob and it will pop back up. Pilot should remain lit.
If it goes out, repeat steps 7 through 9.
MILLIVOLT
THERMOCOUPLE
GENERATOR
*
If the knob does not pop up when released, stop and immediately call your
service technician or gas supplier.
*
If the pilot will not stay lit after several tries, turn the gas control knob
clockwise
to "OFF" and call your service technician or gas supplier.
11. Reinstall door and face. Wait five minutes to allow pilot flame to stabilize and
establish proper draft.
12. Push down and turn gas control knob counterclockwise
to "ON".
13. Push burner rocker switch on the control panel to "ON". If thermostat is to be used, leave switch in "OFF" position and set the
thermostat to desired setting.
14. Reconnect electrical power to appliance.
TO TURNN OFF GASS TTOO AAPPPPLLIIAANNCCEE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
3. Push in gas control knob slightly and turn clockwise
to "OFF" position.
Page 39
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
D. After Appliance is Lit
CAUTION
Prevent accidental appliance operation when not
attended.
Unplug or remove batteries from remote control if absent
or if appliance will not be used for an extended period
of time.
Initial Break-in Procedure
•
•
When you light your appliance, you may notice that it pro-
duces heat which does have an associated odor or smell. If
you feel this odor is excessive it may require the initial three
to four hour continuous burn on high followed by a second
burn up to 12 hours to fully drive off any odor from paint and
lubricants used in the manufacturing process. Condensation
on the inside of the glass is normal.
•
Property damage possible from elevated temperatures.
CAUTION
Smoke and odors released during initial operation.
NOTE: The appliance should be run three to four hours
on the initial start-up. Turn it off and let it cool completely.
Remove and clean the glass. Replace the glass and run the
appliance for an additional 12 hours. This will help to cure
the products used in the paint and logs.
•
•
•
Open windows for air circulation.
Leave room during initial operation.
Smoke may set off smoke detectors.
Smoke and odors may be irritating to sensitive
individuals.
During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the appliance’s initial burning.
WARNING
Fire Hazard.
WARNING
Keep combustible materials, gasoline
and other flammable vapors and liquids
clear of appliance.
Fire Risk.
High Temperatures.
•
Do NOT store flammable materials in the appliance’s
vicinity.
Do NOT use gasoline, lantern fuel, kerosene, charcoal
lighter fluid or similar liquids in this appliance.
Combustible materials may ignite.
Keep combustible household items away from appliance.
Do NOT obstruct combustion and ventilation air.
•
•
•
Do NOT place combustible items on top of or in front of
appliance.
•
Keep furniture, draperies away from appliance.
E. Frequently Asked Questions
ISSUE
SOLUTIONS
Condensation on the glass
This is a result of gas combustion and temperature variations. As the appliance warms,
this condensation will disappear.
Blue flames
This is a result of normal operation and the flames will begin to yellow as the appliance
is allowed to burn for 20 to 40 minutes.
Odor from appliance
When first operated, this appliance may release an odor for the first several hours.
This is caused by the curing of the paint and the burning off of any oils remaining from
manufacturing.
Film on the glass
Metallic noise
This is a normal result of the curing process of the paint and logs. Glass should be
cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the
manufacturing process. A non-abrasive cleaner such as gas appliance cleaner may be
necessary. See your dealer.
Noise is caused by metal expanding and contracting as it heats up and cools down,
similar to the sound produced by a furnace or heating duct. This noise does not affect
the operation or longevity of the appliance.
Page 40
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
10
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do
experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the
corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.
Symptom
Possible Cause
Corrective Action
1. After repeated trig-
gering of the piezo
a. Defective ignitor.
Check the spark at the electrode and pilot. If no spark and electrode
wire is properly connected, replace the ignitor.
button, the spark ignitor
will not light the pilot.
b. Defective pilot or
Using a match, light the pilot. If the pilot lights, turn off the pilot and
misaligned electrode trigger the piezo button again. If the pilot lights, an improper gas/air
(spark at electrode). mixture caused the bad lighting and a longer purge period is recom-
mended. If the pilot will not light, ensure the gap at the electrode and
pilot is one-eighth (1/8) inch to have a strong spark. If the gas is OK,
replace the pilot.
c. No gas or low gas Check the remote shut-off valve from the appliance. Usually, there is
pressure.
a valve near the gas main. There can be more that one (1) valve from
the appliance and the main.
d. No LP in tank.
Check the LP (propane) tank. You may be out of fuel.
2. The pilot will not stay a. Defective thermo- Check that the pilot flame impinges on the thermocouple. Clean and /or
lit after carefully follow-
ing the lighting instruc-
tions.
couple.
adjust the pilot for maximum flame impingement.
Ensure that the thermocouple connection at the gas valve is fully
inserted and tight (hand tighten plus 1/4 turn).
Disconnect the thermocouple from the valve, place one millivolt lead
wire on the tip of the thermocouple and the other meter wire on the
thermocouple copper lead. Start the pilot and hold the valve knob in. If
the millivolt reading is less than 15mV, replace the thermocouple.
b. Defective valve.
If the thermocouple is producing more than 15 millivolts, replace faulty
valve.
3. The pilot is burning,
there is no gas to the
burner, the valve knob is
in the ON position, and
the ON/OFF switch is in
the ON position.
a. ON/OFF switch or Check the ON/OFF switch and wires for proper connections. Place the
wires defective.
jumper wires across the terminals at the switch. If the burner comes on,
replace the defective switch. If the switch is OK, place the jumper wires
across the switch wires at the gas valve. IF the burner comes on, the
wires are faulty or connections are bad.
b. Thermopile may
not be generating
If the pilot flame is not close enough physically to the thermopile, adjust
the pilot flame.
sufficient millivoltage.
Be sure the wire connections from the thermopile at the gas valve ter-
minals are tight and that the thermopile is fully inserted into the pilot
bracket.
Check the thermopile with a millivolt meter. Take the reading at TH-
TP&TP terminals of the gas valve. The meter should read 325 millivolts
minimum, while holding the valve knob depressed in the pilot position,
with the pilot lit, and the ON/OFF switch in the OFF position. Replace
the faulty thermopile if the reading is below the specified minimum.
With the pilot in the ON position, disconnect the thermopile leads from
the valve. Take a reading at the thermopile leads. The reading should
be 325 millivolts minimum. Replace the thermopile if the reading is
below the minimum.
Page 41
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Possible Cause
Corrective Action
3. (Continued)
c. Defective valve.
Turn the valve knob to the ON position. Place the ON/OFF switch in the
ON position. Check the millivolt meter at the thermopile terminals. The
millivolt meter should read greater than 125mV. If the reading is accept-
able, and if the burner does not come on, replace the gas valve.
d. Plugged burner
Check the burner orifice for stoppage. Remove stoppage.
orifice.
e. Wall switch or
wires are defective.
Follow the corrective action in Symptom and Possible Cause 1.a.
Check the switch and wiring. Replace where defective.
4. Frequent pilot outage a. Pilot flame may
Clean and adjust the pilot flame for maximum flame impingement on
problem.
be too high or too
low, or blowing
thermocouple. Follow lighting instructions carefully.
(high), causing safety
pilot to drop out.
5. The pilot and main
burner extinguish while
in operation.
a. No LP in tank.
Check the LP (propane) tank. Refill the fuel tank.
b. Inner vent pipe
leaking exhaust
gases back into the
system.
Check for proper vent connection at flue collar and all vent joints.
c. Horizontal vent
improperly pitched.
The horizontal vent cap should slope down only enough to prevent any
water from entering the appliance.
d. Bad thermopile or Replace if necessary.
thermocouple.
e. Improper vent cap Check for proper installation and freedom from debris or blockage.
installation.
6. Glass soots.
a. Flame impinge-
ment.
Adjust the log set so that the flame does not excessively impinge on it.
Check that logs are placed according to installation instructions.
b. Improper shutter
setting.
Adjust the air shutter at the base of the burner.
c. Debris around
opening at base of
burner.
Inspect the opening at the base of the burner. NO MATERIAL SHOULD
BE PLACED IN THIS OPENING.
7. Flame burns blue
and lifts off burner.
a. Insufficient
oxygen being sup-
plied.
Ensure that the vent cap is installed properly and free of debris. Ensure
that the vent system joints are tight and have no leaks.
Ensure that no debris has been placed at the base of, or in the area of
the air holes in the center of the base pan beneath the burner.
Ensure that the glass is tightened properly on the appliance, particu-
larly on top corners.
Page 42
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintaining and Servicing Appliance
11
Although the frequency of your appliance servicing and
maintenance will depend on use and the type of installation,
a qualified service technician should perform an appliance
check-up at the beginning of each heating season.
CAUTION
Handle glass assembly with care.
NOTE: Clean glass after initial 3-4 hours
operation. Longer operation without cleaning
glass may cause a permanent white film on
glass.
WARNING
Risk of injury or property damage.
When cleaning glass door:
Before servicing:
•
•
•
•
•
Avoid striking, scratching or slamming glass.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white film.
Do NOT clean glass when hot.
Turn off appliance after 3-4 hours of operation andALLOW
TO COOL.
•
•
•
Turn off gas.
Turn off electricity to appliance.
Ensure appliance is completely cooled.
After servicing:
•
•
Replace any screen or barrier that was removed.
Reseal and reinstall any venting removed for servicing.
•
•
Remove and clean glass assembly.
Replace glass assembly and operate appliance for
additional 12 hours.
Refer to maintenance instructions.
WARNING
Annual inspection by qualified technician recommended.
Check:
•
•
•
•
•
•
Condition of glass, glass assembly and glass seal.
Obstructions of combustion and ventilation air.
Obstructions of termination cap.
Burner ignition and operation.
Burner air shutter adjustment
Gas connections and fittings.
Clean:
•
•
Glass
Air passageways, grilles,
control compartment
Burner, burner ports
•
Risk of:
•
•
•
•
Fire
Delayed ignition or explosion
Exposure to combustion fumes
Odors
WARNING
Inspect external vent cap regularly.
•
•
Ensure no debris blocks cap.
Combustible materials blocking cap
may ignite.
•
Restricted air flow affects burner
operation.
Page 43
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
A. Maintenance Tasks
Inspect
Maintenance Tasks
Doors
1. Inspect for scratches, dents or other damage and repair as necessary.
2. Verify no obstructions to air flow.
3. Verify maintenance of proper clearance to combustible household objects.
1. Inspect gasket seal and its condition.
Gasket Seal, Glass
Assembly and Glass
2. Inspect glass for scratches and nicks that can lead to breakage when exposed to heat.
3. Confirm there is no damage to glass or glass frame, Replace as necessary.
4. Verify that latches engage properly and glass attachment components are intact and operat-
ing properly. Replace as necessary.
5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be
removed.
Valve Compartment
and Firebox Top
1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these
areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.
2. Remove any foreign objects.
3. Verify unobstructed air circulation.
Logs
1. Inspect for broken, damaged, or missing logs. Replace as necessary.
2. Verify correct log placement and no flame impingement causing sooting. Correct as neces-
sary.
Firebox
1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as neces-
sary.
2. Replace appliance if firebox has been perforated.
Burner Ignition and
Operation
1. Verify burner is properly secured and aligned with pilot or igniter.
2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if
necessary. USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.
3. Replace ember material with new dime-size and shape pieces. Do not block ports or obstruct
lighting paths.
4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.
5. Inspect for lifting and other flame problems.
6. Inspect orifice for soot, dirt or corrosion.
7. Verify manifold and inlet pressures. Adjust regulator as required.
8. Inspect pilot flame strength. Clean or replace orifice as necessary.
9. Inspect thermocouple/thermopile sensor rod for soot, corrosion and deterioration. Clean with
emery cloth or replace as required.
10. Verify millivolt output. Replace as necessary.
Venting
1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.
2. Confirm that termination cap remains clear and unobstructed by plants, etc.
3. Verify that termination cap clearance to subsequent construction (building additions, decks,
fences or sheds) has been maintained.
4. Inspect for corrosion or separation.
5. Verify weather stripping, sealing and flashing remains intact.
1. Verify operation of remote.
Remote Controls
2. Replace batteries in remote transmitters and battery-powered receivers.
Page 44
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference Materials
12
A. Appliance Dimension Diagram
Dimensions are actual appliance dimensions. Use for reference only. For clearances to combustibles refer to Section 3.
A
D
C
B
E
F
Location
Inches
Millimeters
695
Location
Inches
Millimeters
441
A
B
C
27-3/8
18-1/8
15-3/8
D
E
F
17-3/8
22-3/4
16-1/4
460
578
384
413
Figure 12.1 Appliance Dimensions
Page 45
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Vent Components Diagram
6-3/8 in.
(162mm)
6-1/2 in.
(165mm)
9-1/4 in.
(235mm)
6-1/2 in.
(165mm) 9-5/8 in.
(244mm)
6-3/8 in.
(162mm)
6-5/8 in.
(168mm)
SLP45-BK
6-5/8 in.
(168mm)
9-5/8 in.
(244mm)
SLP90M
17-24 in.
(432-610mm)
6-1/2 in.
(165mm)
11-3/4 in.
(298mm)
5-3/4 in.
(146mm)
6-5/8 in.
(168mm)
SLP12AM
SLP12M
SLP6M
47-3/4 in.
(1213mm)
35-3/4 in.
(908mm)
23-3/4 in.
(603mm)
12-17 in.
(305-432mm)
3-3/4 in.
(95mm)
SLP36M
SLP48M
SLP4M
SLP24M
SLP6AM
4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe
Figure 12.2 SL-D Series Vent Components
Page 46
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
C. Vent Components List
Description
HHT SL-P
M= Multi Pack (6)
Simpson
Dura-Vent ®
Selkirk®
Direct-Temp
Amerivent
Direct®
Security
Secure Vent®
DirectVent Pro
4” Pipe Length, Galvanized
4” Pipe Length, Black
SLP4M
-
-
-
-
SLP4-BK
-
-
-
-
SV4L6
SV4LB6
-
6” Pipe Length, Galvanized
6” Pipe Length, Black
SLP6M
46-DVA-06
4DT-6
-
SLP6-BK
46-DVA-06B
4DT-6B
-
7” Pipe Length, Galvanized
7” Pipe Length, Black
-
-
-
4D7
-
-
-
4D7B
-
9” Pipe Length, Galvanized
9” Pipe Length, Black
-
46-DVA-09
4DT-9
-
-
-
46-DVA-09B
4DT-9B
-
-
12” Pipe Length, Galvanized
12” Pipe Length, Black
SLP12M
46-DVA-12
4DT-12
4D12
SV4L12
SV4LB12
-
SLP12-BK
46-DVA-12B
4DT-12B
4D12B
18” Pipe Length, Galvanized
18” Pipe Length, Black
-
46-DVA-18
4DT-18
-
-
46-DVA-18B
4DT-18B
-
-
24” Pipe Length, Galvanized
24” Pipe Length, Black
SLP24M
46-DVA-24
4DT-24
4D2
SV4L24
SV4LB24
SV4L36
SV4LB36
SV4L48
SV4LB48
SLP24-BK
46-DVA-24B
4DT-24B
4D2B
36” Pipe Length, Galvanized
36” Pipe Length, Black
SLP36M
46-DVA-36
4DT-36
4D3
SLP36-BK
46-DVA-36B
4DT-36B
4D3B
48” Pipe Length, Galvanized
48” Pipe Length, Black
SLP48M
46-DVA-48
4DT-48
4D4
SLP48-BK
46-DVA-48B
4DT-48B
4D4B
Adjustable Length, 3”-6”, Black
Adjustable Length, 3”-6”, Galvanized
Adjustable Length, 3”-7”, Galvanized
Adjustable Length, 3”-7”, Black
Adjustable Length, 3”-12”, Black
Adjustable Length, 3”-12”, Galvanized
Adjustable Length, 3”-14.5”, Galvanized
Adjustable Length, 3”-14.5”, Black
Adjustable Length, 7”, Galvanized
Adjustable Length, 7”, Black
Adjustable Length, 11”-14”, Galvanized
Adjustable Length, 11”-14”, Black
Adjustable Length, 12”, Galvanized
Adjustable Length, 12”, Black
Adjustable Length, 16”, Galvanized
Adjustable Length, 16”, Black
Adjustable Length, 24”, Galvanized
Adjustable Length, 24”, Black
2’ Flexible Pipe Length
SLP6A-BK
-
-
-
SLP6AM
-
-
-
-
-
46DVA-08A
-
-
-
-
46DVA-08AB
-
-
-
SLP12A-BK
-
-
-
-
SLP12AM
-
-
-
-
-
46DVA-16A
-
-
-
-
46DVA-16AB
-
-
-
-
-
-
4D7A
-
-
-
-
4F7AB
-
-
-
4DT-AJ
-
-
-
-
4DT-AJB
-
-
-
4DTAJ12
-
4D12A
SV4LA12
-
4DTAJ12-B
-
4D12AB
SV4LBA12
-
46DVA-16A
-
4D16A
-
-
46DVA-16AB
-
-
-
-
-
-
-
SV4LA24
-
-
-
-
SV4LBA24
SLP-FLEX-2
SLP-FLEX-3
SLP-FLEX-5
SLP-FLEX-10
-
-
-
-
-
3’ Flexible Pipe Length
-
-
-
-
5’ Flexible Pipe Length
-
-
-
-
10’ Flexible Pipe Length
-
2280
-
-
-
3” x 35’ Flex Extension
-
-
-
4” x 35’ Flex Extension
-
2281
-
-
-
-
45° Elbow, Galvanized
SLP45M
SLP45-BK
-
-
-
-
45° Elbow, Black
See Swivel
46DVA-E45
4DT-EL45B
-
4D45LB
-
SV4EBR45
SV4E45
45° Elbow, Swivel, Galvanized
Page 47
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
Description
HHT SL-P
M= Multi Pack (6)
Simpson
Dura-Vent ®
Selkirk®
Direct-Temp
Amerivent
Direct®
Security
Secure Vent®
DirectVent Pro
45° Elbow, Swivel, Black
-
46DVA-E45B
-
-
SV4EB45
90° Elbow, Galvanized
SLP90M
See Swivel
4DT-EL905
4D90LS
-
90° Elbow, Black
SLP90-BK
See Swivel
4DT-EL90SB
4D90LBS
SV4EBR90
90° Elbow, Swivel, Galvanized
90° Elbow, Swivel, Black
-
46DVA-E90
-
-
SV4E90
-
46DVA-E90B
-
-
SV4EB90
Adjustable Flashing, 0/12-6/12
Adjustable Flashing, 7/12-12/12
Attic Insulation Shield - Cold Climates 36”
Attic Insulation Shield 12”
Attic Insulation Shield, Adjustable 11”-20”
Cathedral Support Box
SLP-RF6M
46DVA-F6
4DT-AF6
4DF
SV4FA
SLP-RF12M
46DVA-F12
4DT-AF12
4DF12
SV4FB
-
-
-
4DAIS37
-
SLP-AS2M
-
-
4DAIS12
SV4RSA
-
46-DVA-IS
-
-
-
SLP-CCS-BK
46DVA-CS
4DT-CSS
4DRSB
SV4CSB
Ceiling Support
-
46DVA-DC
4DT-CS
4DFSP
SV4SD
Co-Axial to Co-Lineal Appliance Connector
Decorative Ceiling Firestop - Black
Decorative Radius Cover
-
SLP-DCF-BK
DRC-RADIUS
SLP-FSM
SLP-FLEX-TRAP
SLP-FLEX-TRAP30
-
46DVA-GCL
-
-
-
-
-
-
-
-
-
-
-
Firestop Spacer/Ceiling Firestop
Flex Trap Cap with Firestop
Flex Trap Cap with Firestop and 30’ Flex Pipe
Masonry Chimney Conversion Kit
Offset Support
46DVA-FS
4DT-FS
4DFSP
SV4BF
-
-
-
-
-
-
-
-
-
46DVA-KMC
-
4DT-OS
-
-
-
46DVA-ES
-
-
SV4SU
-
Offset Wall Thimble, Black
Silicone Roof Flashing, 4” to 8” pipes (6)
Storm Collar
SLP-WT-BK
RF4-8M
SLP-SCM
-
-
-
-
-
-
46DVA-SC
4DT-SC
4DT-TP
4DT-WS/B
-
4DSC
4DFPB
4DWS
-
SV4FC
SV4LA
SV4BM
SV4PF
SV4RSM
Trim Plate, Black
-
Wall Support Band
SLP-HVSM
-
46-DVA-WS
-
Wall Thimble Support Box/Ceiling Support
Wall Thimble, Black
SLP-WSM
46DVA-WT
4DT-WT
4DWT
TERMINATION CAPS & KITS
Basic Horizontal Termination Kit (A)
Chimney Liner Termination Kit
Horizontal Square Termination Cap
Horizontal Termination Kit (B)
RHVK Snorkel Kit
-
46DVA-KHA
46DVA-GK
46DVA-HC
46DVA-KHC
844-8921
4DT-HKA
4DHTK2
SV-SHK
-
-
-
4DHC
4DHTK1
-
-
SV4CHC
SV-HK
-
SLP-HHW2
4DT-HHC
4DT5-HKB
-
-
-
Snorkel Termination 14”
SLK-SNKD
-
46DVA-SNK14
46DVA-SNK36
-
4DT-ST14
4DT-ST36
-
4D12S
4D36S
-
SV4STC14
SV4STC36
-
Snorkel Termination 36”
LINK-STOVE
*Stove Adaptor Kit (Vertical Cap Kit)
Trapezoid Termination Kit (3-1/8”-4-3/4”)
Trapezoid Termination Kit (5-1/4” X 9-1/4”)
Vertical Termination Cap
SLP-TRAP1
SLP-TRAP2
SLP-TVHW
-
-
-
-
46DVA-VCH
4DT-VKC
4DVT
SV4CGV
* Stove Adaptor Kit (Vertical Cap Kit) Includes 30’-4” flex, adapters, wall thimble, masonry, ZC flashing, 991DA vertical cap.
1
NOTES: Before cutting any holes check pipe manufacturers current instructions.
2Each pipe manufacturer has their own list of parts for kits.
3SL is not interchangeable with SLP.
Page 48
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
TIARA PETITE B
D. Service Parts List
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date:
(NG, LP) Exploded Parts Diagram
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer's VIP site. When
ordering, supply serial and model numbers to ensure correct service parts.
12
10
11
8
9
13
7
6
14
15
3
4
2
5
1
Item
Description
Bulkhead with Flex Tube
Air Shutter Assembly
Baffle
Item
Description
1
2
3
4
5
6
7
8
9
Adapter, DV
10 Blower Shroud Top
11 Relief Door Bracket
12 Relief Door Assembly
13 Latch, Draw
Baffle Back
Damper Assembly
Gasket, Adapter, Elbow
Blower Shroud Back
Flue Shield
14 Door/Glass Assembly
15 Door Retainer
Page 49
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
TIARA PETITE B
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date:
D. Service Parts List
(cont’d.)
(NG, LP) Exploded Parts Diagram
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer's VIP site. When
ordering, supply serial and model numbers to ensure correct service parts.
28
25
27
26
24
29
30
23
22
31
21
1
2
20
3
19
16
17
18
Item
16
17
18
19
20
21
22
23
Description
Item
24
Description
Knob, Extension, ON/OFF
Knob, Extension, HI/LO
Valve Cover
Side, Left or Right (interchangeable)
Back Shield
25
Switch Bracket
26
Ignition Module
27 Switch, Rocker, ON/OFF
Valve, Gas
Top
28
29
30
Burner with Neck Assembly
Gasket, Pilot
Front
Log Set Assembly
Pilot Assembly
31 Valve Bracket
Page 50
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
TIARA PETITE B
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date:
D. Service Parts List
(cont’d.)
(NG, LP) Exploded Parts Diagram
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer's VIP site. When
ordering, supply serial and model numbers to ensure correct service parts.
Item
#
Part Description
Alphabetical Order
SKU
9
2
Adapter, DV
7000-162
7016-017
7016-140
7016-125
7016-126
BK-GAS
Air Shutter Assembly
25 Back Shield
3
4
Baffle
Baffle Back
Blower Assembly
Blower Shroud Back
7
7016-132
7016-118
7000-156
BRNR-TPB
7010-152
7016-120
230-1900
10 Blower Shroud Top
Bulkhead with Flex Tube
1
21 Burner with Neck Assembly
Burner Stop
Burner Support
Cable/Switch Assembly
MBK: 7026-003
BR: 7026-008
CES: 7026-011
CTO: 7026-012
Component Pack Assembly, Matte Black (includes warranty card, ON/OFF valve, mineral wool, leveling assembly, snap disc bracket,
restrictor, owner’s manual, fasteners, and Touch-up Paint.)
Conversion Kit, LP
Conversion Kit, NG
Damper Assembly
LPK-TPB
NGK-TPB
7016-006
7016-117
GLA-TPB
7016-134
7000-197
7016-122
7016-130
See page 52
460-0610
7016-023
230-1880
5
32 Door Frame
14 Door/Glass Assembly
15
8
Door Retainer
Flex Line 3/8 Flare x 22L
Flue Collar
Flue Shield
29 Front
6
Gasket, Adapter Elbow
33 Glass Assembly Only
19 Ignition Module
17 Knob, Extension, HI/LO
16 Knob, Extension, ON/OFF
13 Latch, Draw
571-533
571-534
229-0640
LOGS-TPB
15697A
30 Log Set Assembly
ON/OFF Valve
Orifice Insert #49 (NG)
842-1220
TOUCHUP-CES
7000-304
TOUCHUP-CTO
Paint, Touch-up, Espresso
Paint, Touch-up, Matte Black
Paint, Touch-up, Tuscan Olive
Page 51
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
TIARA PETITE B
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date:
D. Service Parts List
(cont’d.)
(NG, LP) Exploded Parts Diagram
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer's VIP site. When
ordering, supply serial and model numbers to ensure correct service parts.
Item
#
Part Description
Alphabetical Order
Part #
23 Pilot Assembly (NG)
Pilot Shield
230-1781
7016-164
7016-005
7016-121
7016-145
See chart below
7009-108
7016-143
230-0730
See chart below
7016-142
7016-133
842-0230
842-0240
7010-156
12 Relief Door Assembly
11
Relief Door Bracket
Restrictor
24 Side, Left or Right (interchangeable)
Snap Disc Bracket
26 Switch Bracket
27 Switch, Rocker, ON/OFF
28 Top
31 Valve Bracket
18 Valve Cover
20 Valve, Gas (LP)
20 Valve, Gas (NG)
Wire Harness
CAST PARTS - INDIVIDUAL PIECES
Add color code to SKU. Example 476-0030MBK
Part Description
Front
SKU
476-0030
476-0020
476-0010
Color Code
BK - Matte Black
Side
Top
PBR - Porcelain Brown
CES - Powder Coat Espresso
CTO - Powder Coat Tuscan Olive
Page 52
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
TIARA PETITE B
Beginning Manufacturing Date: 4-04
Ending Manufacturing Date:
E. Accessories
(NG, LP) Exploded Parts Diagram
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealer's VIP site. When
ordering, supply serial and model numbers to ensure correct service parts.
Part Description
Part #
Alphabetical Order
Mineral Wool
200-2550
Remote Control 110 VAC
RC-SMART-HNG
SMART-BATT-HNG
SMART-STAT-HNG
WSK-21
Remote Control - Battery Remote Thermostat
Remote Control Thermostat with Timer
Wall Switch Kit, Off-White
Wall Switch Kit, White
WSK-21-W
WH-STAT
Wall Thermostat
Warming Shelves, Matte Black
Warming Shelves, Porcelain Almond
Warming Shelves, Porcelain Black
Warming Shelves, Porcelain Brown
TPSK-BK
TPSK-AL
844-9520
TPSK-BR
Page 53
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
F. Service and Maintenance Log
Date of Service
Performed By
Description of Service
Page 54
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
G. Warranty Policy
LIMITED LIFETIME WARRANTY
HEAT & GLO GAS APPLIANCE PRODUCTS
BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., located at 20802 Kensington Boulevard,
Lakeville, MN 55044, (“HEAT & GLO”) warrants to the original owner that your new HEAT & GLO Gas Appliance (the “Product”) will be free
from defects in materials and workmanship for a period of one year from the date of installation. During the first year, HEAT & GLO will replace
or repair, at its discretion, any defective components at its sole cost and expense, including payment of all reasonable labor costs incurred in
replacing or repairing such components. This basic warranty is subject to the conditions, exclusions and limitations described below.
EXTENDED LIFETIME COVERAGE. HEAT & GLO warrants that the firebox, heat exchanger, log(s), and burner will not be defective in mate-
rial or workmanship during the period the Product is owned by the original owner, subject to the following conditions, exclusions and limitations
described below.
CONDITIONS, EXCLUSIONS AND LIMITATIONS:
1. This warranty applies to the original owner only and is nontransferable.
2. This warranty applies only to Products installed in the United States of America or Canada.
3. This warranty is limited to the replacement or repair of defective components or workmanship and HEAT & GLO may fully discharge all
obligations under this warranty by repairing or replacing, at its discretion, the defective components. The maximum amount recoverable
under this warranty is limited to the purchase price of the Product and, if HEAT & GLO is unable to provide replacement or repair in an
expedient and cost-effective manner, HEAT & GLO may discharge all obligations under this warranty by refunding the purchase price of
the Product. IN NO EVENT SHALL HEAT & GLO BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY
DEFECTS IN THE PRODUCT.
4. Any labor and related repair charges relating to the costs and expenses of replacing or repairing defective components under the Limited
Lifetime Warranty are not covered by this warranty, except as provided for under the Basic One-Year Warranty.
5. Components and parts made by other manufacturers, whether sold with the Product or added thereafter, are NOT covered by this warranty
unless expressly authorized and approved by HEAT & GLO in writing.
6. Any damages caused by environmental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure,
air handling devices such as exhaust fans or forced air furnaces, or other such causes are not covered by this warranty.
7. This warranty will be void if:
a) The Product is not installed, operated and maintained in compliance with local building codes and with the instructions in the Installer’s
Guide, Owner’s Guide and Listing Agent Identification Label furnished with the Product.
b) Any parts or components made by other manufacturers are added or used in the Product, unless expressly authorized and approved
by HEAT & GLO in writing.
c) Any service work is performed on the Product by anyone other than an authorized HEAT & GLO representative.
d) The Product is damaged due to shipping, improper handling, accident, abuse or misuse.
e) Fuels other than those specified in the Installer’s Guide and Owner’s Guide are used.
f ) Modification was made to the Product which was not expressly authorized and approved by HEAT & GLO in writing.
EXCEPT TO THE EXTENT PROVIDED BY LAW, HEAT & GLO MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO THE DURATION OF THE WARRANTY SPECIFIED
ABOVE.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow exclusion or limitation of incidental or consequential
damages, so those limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which
vary from State to State.
If warranty service is needed you should contact your installing dealer and if the installing dealer is unable to provide necessary parts or com-
ponents, contact the nearest authorized HEAT & GLO dealer or supplier.
NOTES TO CUSTOMER:
1. In order to insure proper installation, operation and maintenance HEAT & GLO strongly recommends annual ser-
vicing by an authorized HEAT & GLO dealer.
2. Please complete this information and retain this warranty in a safe place for future reference: Installation Date:______
Model #:_________________ Serial #:______________ Installing Contractor:_________________________
3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications
and prices of the Product. HEAT & GLO also reserves the right to discontinue styles and products.
060-981E 10/07
© 2007 Hearth & Home Technologies Inc.
Page 55
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
H. Contact Information
CONTACT INFORMATION:
Heat & Glo, a brand of Hearth & Home Technologies, Inc.
20802 Kensington Boulevard
Lakeville, MN 55044
Please contact your Heat & Glo dealer with any questions or concerns.
For the number of your nearest Heat & Glo dealer,
CAUTION
Do NOT discard this manual.
•
•
•
Important operating and maintenance
instructions included.
Read, understand and follow these instruc-
tions for safe installation and operation.
Leave this manual with party responsible
for use and operation.
Your Records for Model:
Tiara Petite B
DEALERSHIP WHERE PURCHASED:
SERIAL NUMBER:
DATE PURCHASED:
DATE INSTALLED:
___________________________
___________________________
___________________________
__________________________________________________________________
____________________________________________________________________
____________________________________________________________________
DEALER TELEPHONE: ________________________
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322,
4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495,
5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112,
5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226,
6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942,
6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884,
D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or
other U.S. and foreign patents pending.
Page 56
Heat & Glo · Tiara Petite B · 7026-101K
August 1, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Graham Field Scale LF1007 User Manual
Grundig Wheelchair HS 7630 User Manual
Harbor Freight Tools Heat Gun 47269 User Manual
Hotpoint Washer HAULT 943 User Manual
HP Hewlett Packard Printer 2000CP series User Manual
HP Hewlett Packard Projection Television HP ID5220N User Manual
Hunter Fan Dollhouse 20730 User Manual
IBM Laptop 380XD User Manual
IBM Network Card HPSS User Manual
Ice O Matic Refrigerator CD220 User Manual