Check with your local building code agency before you begin installation to ensure compliance with local codes, including
the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need
clarification of any of the instructions contained here, contact the Technical Services Dept., Hearth & Home Technologies
Inc., phone 1-888-427-3973 or 1-800-927-6841.
CAUTION
DO NOT DISCARD THIS MANUAL
•
Read, understand
and follow these
instructions for safe
installation and
operation.
•
Leave this manual with
party responsible for
use and operation.
•
Important operating
and maintenance
instructions included.
WARNING
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
Glass and other surfaces are hot during
operation and cool down.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
•
•
Keep children away.
CAREFULLY SUPERVISE children in same room as
appliance.
• What to do if you smell gas:
•
•
Alert children and adults to hazards of high
temperatures.
Keep clothing, furniture, draperies and other
combustibles away.
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
In the Commonwealth of Massachusetts:
•
•
•
This appliance must be installed by a licensed plumber
or gas fitter.
The chimney flue damper, when used with gas logs, will
be welded open or completely removed.
A CO detector shall be installed in the room where the
appliance is installed.
Note: An arrow () found in the text signifies change in
content.
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1
2
Listing and Code Approvals
A. Appliance Certification. . . . . . . . . . . . . . . . . . . . . . . . .4
B. Table 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Getting Started
A. Size of Firebox. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
B. Negative Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
C. Tools and Supplies Needed. . . . . . . . . . . . . . . . . . . . . 5
D. Inspect the Appliance and Components . . . . . . . . . . . 5
E. Components of the Gas Hearth Kit . . . . . . . . . . . . . . . 6
3
4
Appliance Preparation
A. Gas Supply Connection. . . . . . . . . . . . . . . . . . . . . . . . 7
B. Convert to Left Side Gas Piping. . . . . . . . . . . . . . . . . . 7
C. Gas Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Installation Instructions
A. Install the Damper Stop . . . . . . . . . . . . . . . . . . . . . . . .9
B. Install the Burner/Pan Assembly . . . . . . . . . . . . . . . . . 9
C. Install the Grate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
D. Place Sand and Rockwool. . . . . . . . . . . . . . . . . . . . . . 9
E. Install the Logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
F. Adjust the Burner Flame . . . . . . . . . . . . . . . . . . . . . . 10
G. Inspect the Venting System. . . . . . . . . . . . . . . . . . . . 10
5
6
Operating Instructions
A. Lighting Instructions. . . . . . . . . . . . . . . . . . . . . . . . . .11
B. Glass Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
C. Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . 12
Maintaining and Servicing the Appliance
A. Servicing Your Appliance. . . . . . . . . . . . . . . . . . . . . . 13
B. Cleaning Your Appliance . . . . . . . . . . . . . . . . . . . . . . 13
C. Annual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . .13
D. Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7
Reference Materials
A. Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . 14-17
B. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
C. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . .20
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Listing and Code Approvals
1
A. Appliance Certification
WARNING
The Gas Log Hearth Kits have been tested and listed in the
U.S. in accordance with ANSI Z21.84-2003 (Gas Log Set).
They have been listed by OMNI Test Labs for installation and
operation in the United States and Canada as described in
these Installation and Operating Instructions. All components
are UL, OMNI or CSA safety certified.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with
this appliance. For assistance or additional information
consult a qualified installer, service agency or the gas
supplier.
Check with your local building code agency prior to installing
this appliance to ensure compliance with local codes,
including the need for permits and follow-up inspections. In
the absence of local codes, comply with the National Fuel
Gas Code, ANSI Z223.1-Latest Edition in the U.S. If any
assistance is required during installation, please contact
your local dealer or call the Technical Services Department
at 1-888-427-3973 or 1-800-927-6841.
WARNING
Fire Risk
Exhaust Fumes Risk
•
Do NOT use this appliance as a “vent-free
heater.
B. Table 1
The flue must be permanently open. Refer
to Table 1.
Product
MHK18NG
MHK24NG
STMHK18NG STMHK24NG
Inlet BTU / KW /HR
Nat.
Nat.
74,000 / 21.7
10.0 / .052
84,000 / 24.6
10 / .052
65,000 / 19
10.0 / .052
75,000 / 22
10.0 / .052
Max. Inlet Pressure
IN. WC / KPa
Nat.
Nat.
3.5 / .018
(#26) .147
3.5 / .018
(#20) .161
3.5 / .018
(#30) .128
3.5 / .018
(#28) .141
Min. Inlet Pressure IN.
WC / KPa
Orifice Size
In. / mm
Front
Rear
28 / 71.1
16 / 40.6
14 / 35.6
16 / 40.6
34 / 86.4
18 / 45.7
16 / 40.6
18 / 45.7
28 / 71.1
-
34 / 86.4
-
Minimum Fireplace
Opening Size
In. / cm
Depth
Height
16 / 40.6
18 / 45.7
16 / 40.6
18 / 45.7
39 / 251.6
48 / 309.7
39 / 251.6
48 / 309.7
Min. Vent Opening in
Square In. / cm
4
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
2
A. Size of Firebox
See Table 1 in Section 1.B.
CAUTION
Sharp Edges
B. Negative Pressure
•
Wear protective gloves
and safety glasses during
installation.
Negative pressure results from the imbalance of air avail-
able for the fireplace to operate properly. Causes for this
imbalance include:
•
•
•
Exhaust fans (kitchen, bath, etc.).
Range hoods.
Combustion air requirements for furnaces, water heaters
and other combustion appliances.
Clothes dryers.
•
•
WARNING
Location of return-air vents to furnace or air
conditioning.
Asphyxiation Risk
This appliance produces carbon monoxide
(CO).
•
•
Imbalances of the HVAC air handling system.
Upper level air leaks: recessed lighting, attic hatch
opening, duct leaks.
•
The free opening areas (in square inches)
of the chimney damper as shown in the
tables must be met.
C. Tools and Supplies Needed
Tools and supplies normally required for installation:
Pliers
•
•
User must make sure damper is locked
open.
The installer is responsible to ensure
proper ventilation of flue gases before
appliance is used.
Phillips screwdriver
Tape measure
Fire needs to draft properly for safe
operation.
Crescent wrenches
Gas shutoff valve
Non-corrosive leak check solution
3/4 in. wrench, 7/16 in. wrench
D. Inspect the Appliance and Components
WARNING
•
Remove the contents from the carton. Attached to the
burner are tags identifying the manufacturer name, serial
number, model number (including gas log size), BTU
ratings, gas type, etc.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
•
Review the attached tags before proceeding. Ensure
that all minimum fireplace dimension requirements are
achieved using Table 1 in Section 1.B. See Figure 2.1.
Ensure the gas type provided in the fireplace coincide
with the gas type marked on the tag.
•
Installation and use of any damaged appliance or
vent system component.
Modification of the appliance or vent system.
Installation other than as instructed by Hearth & Home
Technologies.
•
•
•
•
Improper positioning of the gas logs or the glass
door.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Any such action may cause a fire hazard.
Figure 2.1 Measure Firebox
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
5
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
WARNING
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
Keep appliance dry.
•
Mold or rust may cause
odors.
Water may damage controls.
•
•
•
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
•
Report damaged parts to dealer.
WARNING
E. Components of the Gas Hearth Kit
The Burner/Hearth Kit consists of the following:
Do NOT use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
•
•
•
•
•
•
•
•
•
•
Burner/Pan Assembly
Grate Assembly
Glowing Embers
Sand
Lava Rock
Damper Stop
Aluminum Tubing Assembly
Brass Elbow Connector
Brass Orifice & Cap
Log Set (sold separately)
WARNING
Shock Risk
Fire Risk
Use ONLY optional accessories approved
for this appliance.
•
•
•
Using non-listed accessories voids
warranty.
Using non-listed accessories may result
in a safety hazard.
Only Hearth & Home Technologies
approved accessories may be used
safely.
6
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance Preparation
3
Note: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI 223.1.
Installation should be done by a qualified installer approved
and/or licensed as required by the locality. (In the Common-
wealth of Massachusetts installation must be performed by
a licensed plumber or gas fitter.)
WARNING
Fire Risk
Explosion Risk
Verify inlet pressures.
•
High pressure may cause overfire
condition.
•
Low pressure may cause explosion.
A. Gas Supply Connection
Install regulator upstream of valve if line
pressure is greater than 1/2 psig.
Ensure fittings are of the appropriate size and type on the
gas line connection. If the tubing has to be cut to length be
sure to use the proper cutting and flaring tool. Also, be care-
ful not to crimp the tubing while bending. If the tubing be-
comes crimped, do not use for installation.
B. Convert to Left Side Gas Piping
•
•
Remove the brass elbow from the right side.
Remove the cap from the left side.
WARNING
Note: Prior to installing the fittings, use Teflon tape or joint
compound on the male threads.
Gas Leak Risk
•
Support control when attaching pipe to
prevent bending gas line.
•
•
Replace the cap on the opposite end of the burner tube.
Install the brass elbow on the left side of the burner.
Joint compound or Teflon tape must be used on all threaded
male connections to ensure a tight seal.
WARNING
WARNING
Fire Risk
Explosion Risk
Fire Risk
Explosion Risk
Personal Injury Risk
•
Gas build-up during line purge may
ignite.
Purge should be performed by qualified
technician.
Ensure adequate ventilation.
Ensure there are no ignition sources such
as sparks or open flames.
•
An explosion could occur if a connection is
made directly to an unregulated propane (LP)
tank.
•
•
Note: An individual manual shutoff valve (not supplied) is
required when installing this appliance. The manual shutoff
valve must be located in an easily accessible area, no more
than 6 feet from the appliance.
Note: A listed (and Commonwealth of Massachusetts
approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and flexible gas connector are connected to the 1/2 in.
(13 mm) control valve inlet.
•
If substituting for these components, please consult
local codes for compliance.
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
7
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Gas Supply Pressure: Minimum inlet gas supply pressure
must be 3.5 in. W.C. for the purpose of input adjustment.
Maximum inlet gas pressure must not exceed 10.0 in. W.C.
The gas line supplying the appliance must be sufficient
size to furnish the appropriate supply pressure to the
appliance while operating in the “High” setting. (Minimum
line ID of 1/2 in. required if the line is longer than 20 ft.
Gas Line Pressure Test: Perform pressure test according
to state and local code (if pressure exceeds 1/2 in. psi [3.5
kPa]) before appliance is connected. Be sure to release
air pressure from the gas line before connection is made
to the appliance.
Gas Leak Test: Make sure the gas connections are tight.
Turn on the gas and coat each joint with a non-corrosive
gas leak check solution. Air bubbles will form indicating
any leaks. DO NOT USE A FLAME OR ANY TYPE OF
IGNITION SOURCE TO CHECK FOR LEAKS. All leaks
must be corrected before proceeding with installation.
The appliance must only be installed in a solid-fuel burning
fireplace with the flue damper clamped open. The fireplace
must be constructed of non-combustible material.
The minimum permanent free opening (in square inches)
that must be provided by the fireplace chimney or damper
to vent the flue gases is provided in Table 1. If the free
opening is smaller than the specified area, do not use this
appliance.
C. Gas Pressure
Proper input pressures are required for optimum appliance
performance. Gas line sizing requirements need to be made
following NFPA51.
WARNING
•
•
Fire Risk
Explosion Risk
High pressure will damage valve.
•
Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
•
Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
•
•
WARNING
CHECK FOR GAS LEAKS
Fire Risk
Explosion Risk
Asphyxiation Risk
•
•
•
Check all fittings and connections.
Do not use open flame.
•
•
The damper must be removed or fixed in a manner in
which will secure it open. Some jurisdictions require the
damper to be removed or permanently welded fully open.
Check with state and local codes.
Be sure that the chimney is completely unobstructed to
ensure proper ventilation of flue gases including carbon
monoxide (CO). CO (a poisonous gas) is tasteless,
odorless, colorless and undetectable without proper
equipment.
After the gas line installation is complete,
all connections must be tightened and
checked for leaks with a commercially
available, non-corrosive leak check
solution. Be sure to rinse off all leak check
solution following testing.
Fittings and connections may have loosened
during shipping and handling.
High Altitude Derate
In the USA, input BTU shall be derated 4% (one orifice size)
per 1000 feet for altitudes above 2000 feet. In Canada, input
BTU shall be derated 10% (two orifice sizes) at altitudes
from 2000-4500 feet.
8
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
4
A. Install the Damper Stop
•
Open the damper to the fully open position and secure it
open with the stop as shown in Figure 4.1.
If the damper stop doesn’t fit your application, use a
permanent means that will keep the damper open at
least to the minimum vent opening as outlined in Table 1,
Section 1.B.
•
Figure 4.2 Center Grate Over Burner Pan
D. Place Sand and Rockwool
•
•
•
•
Pour the sand into the burner pan. Sand should follow the
slope of pan, covering it and the burner tube completely.
Allow the sand to spill out the front of the pan and over
the sides onto the fireplace floor.
Lightly place dime-sized pieces of rockwool evenly on top
of the sand or vermiculite.
The gas burns at the point of the least resistance. In
case of an uneven flame pattern it may be necessary to
adjust the materials in the pans (using an object such as
a screwdriver) to achieve the desired effect.
Figure 4.1 Damper Operation
B. Install the Burner/Pan Assembly
The burner/pan assembly is shipped ready for right-hand
gas connection. See Section 3.B. for left-hand connection.
WARNING
Explosion Risk
•
Remove the existing cap or gas jet assembly from the
gas stub in your fireplace. Clean the threads using a wire
brush or steel wool. Apply Teflon tape or pipe dope to the
steel fitting and attach the provided brass adapter to the
stub.
•
Follow rockwool placement instructions
in this manual.
Replace rockwool material annually.
•
Improperly placed rockwool interferes with
proper burner operation.
•
•
•
Place the burner/pan assembly in the fireplace. The pan
should be centered both front to back and side to side.
Bend the provided gas connector to facilitate its installation
between the burner and the gas stub.
Attach one end of the gas connector to the brass elbow
or safety pilot fitting. Attach the other end to the brass
adapter at the gas tube.
Note: For best results, do not pack down the rock wool.
The placement of rock wool can have an effect on flame
pattern and may need to be adjusted to achieve a desired
appearance.
C. Install the Grate
•
The grate should be centered over the burner pan, side
to side. If the grate sits toward the front of the burner pan,
the flames will be larger coming through the logs. If the
grate sits toward the back of the burner pan, the ember
bed will be more prominent. Refer to Figure 4.2.
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
9
Download from Www.Somanuals.com. All Manuals Search And Download.
E. Install the Logs
F. Adjust the Burner Flame
•
The burner flame can be adjusted at the manual shutoff
valve beside the fireplace to obtain the desired flame
appearance.
WARNING
•
The flame color will stabilize after ten minutes of
operation.
Fire Risk
Explosion Risk
Personal Injury Risk
G. Inspect the Venting System
Failure to position the parts in accordance
with the diagrams provided with the log
packages or failure to use only parts
approved with this appliance may result in
property damage or personal injury.
The fireplace venting system is designed and constructed to
develop a positive flow adequate to remove flue gases to the
outside atmosphere. See fireplace installation instructions.
A spillage test must be made before the installed
appliance is left with the consumer
•
•
Install the logs using the installation instructions included
with them.
•
•
•
Close all doors and windows in the home.
Light the log set.
After three minutes, test with a smoke match, smoke
candle, stick incense or cigarette one inch below the top of
the opening (lintel) moving across the full width. If spillage
(smoke drawn into the room) occurs, it will most likely be
near the top, outside corners.
Light the burner as outlined in the operating section. Allow
the flame pattern to stabilize. If you are satisfied with the
flame pattern go to the next step. If you want more or less
flame around the front log, turn off the gas and move the
grate backward or forward.
•
•
Once you are satisfied, turn on the gas and go on to the
next step.
Possible Cures if Spilling Occurs
•
•
The damper should be fully open.
Arrange the top logs as shown in your log set up
instructions. Light the burner as outlined in the operating
instructions and allow the flame to stabilize.
Spread the lava rock around the outside of the burner
pan on the floor of the fireplace. If possible, cover the gas
connector with the cinders.
The fireplace opening needs to be reduced by adding a
drop panel across the top under the lintel.
The air supply from outdoors needs to be increased. Open
the outside air kit if the appliance is so equipped, or crack
open a door or window.
•
•
•
If necessary, seek expert advice. Do not operate this
appliance.
Cleaning
Note: If your log set is the burnt-out type, place the rock
wool in the center of the logs to give a glowing ember
effect.
•
Periodic examination and cleaning of the venting system
of the fireplace should be done before initial use and at
least annually by a qualified agency.
WARNING
Fire Risk
Explosion Risk
Inspect external vent cap regularly.
•
•
Ensure no debris blocks cap.
Combustible materials blocking cap may
ignite.
•
Restricted air flow affects burner
operation.
10
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
5
A. Lighting Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING! IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a manually lighted burner and must be lit by hand. When lighting the burner, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•
•
•
•
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
C. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system and any gas control that has been under water.
D. Use only your hand to push in or turn the gas control handle. Never use tools. If the handle will not push in or turn
by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or
explosion.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information previously listed above.
2. Turn gas control manual valve to the full “OFF” position.
3. Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B”
in the safety information above on this label. If you don’t smell gas, go to the next step.
4. Place a lit match on the surface of the burning embers. Do not hold match in hand.
5. Turn gas control manual valve to the full “ON” position.
6. If appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service
technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
Turn manual gas control handle to “OFF” position. Do not force.
(Located in wall or floor
near fireplace)
(Place lit match in ember bed before turning on valve)
Valve
Valve Key
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
11
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Aqualifiedservicetechnicianmustperforminstallation
andrepair.Theapplianceshouldbeinspectedandcleaned
annually by a qualified service technician. More frequent
cleaning may be required due to excessive lint, dust, pet
hair, etc. It is imperative that the control compartments,
burners and air passageways are unobstructed during
operation.
B. Glass Doors
If your fireplace is equipped with glass doors:
•
Glass doors should be in fully open poisition when
appliance is operating.
•
Operating in the closed position will block the radiant heat
output and may cause incomplete combustion of the gas
and minimize overheating of any valve installation.
-
Review proper placement of logs, rockwool, lava rock,
sand or vermiculite.
-
-
Ensure there are no gas leaks.
Ensure the flow of combustion and ventilation air is not
obstructed (front grilles and vent caps).
WARNING
Fire Risk
•
•
•
Before installing into a solid fuel burning fireplace, the
chimney and firebox should be inspected and cleaned to
remove soot, creosote, ashes, paint, bird nests etc.
Annual examination of the chimney must be performed
by a qualified agency to ensure proper ventilation of flue
gases created by this appliance.
Have the chimney and adjacent structure inspected
and cleaned by qualified professionals. Hearth & Home
Technologies recommends that NFI certified professionals,
or technicians under the direction of certified professionals,
conduct a minimum of an NFPA 211 Level 2 inspection
of the chimney.
Replace component parts of the chimney and fireplace as
specified by the professionals.
Ensure all joints are properly engaged and the chimmney
is properly secured.
Do not allow fans to blow directly into the fireplace. Avoid
any drafts that alter burner flame pattern.
Do not use a blower insert, heat exchanger insert or other
accessories not approved for use with this appliance.
Solid fuels shall not be burned in a fireplace where a
decorative appliance is installed.
Explosion Risk
Do not close the glass doors during appliance
operation.
•
Could cause incomplete combustion of
the gas.
•
Glass doors may be closed when the hearth kit is not being
used.
C. Important Safeguards
•
Other Fuels
•
•
•
•
-
Althoughyourgaslogsetisveryrealisticinappearance,
it is not a real woodburning fire and must not be used
for burning any fuel other than natural gas.
To avoid irreparable damage to the appliance and/or
personal injury, wood, matches, paper, garbage or any
other material must not be placed or thrown on top of
the logs.
-
•
Appliance Safety
-
-
-
To avoid personal injury, do not touch hot surfaces
when the appliance is operating.
Always ensure that the fireplace screen is closed when
the appliance is operating.
Close supervision is necessary when the appliance is
being used near children.
•
If glass doors are present, the glass doors must be fully
opened while appliance is in operation.
•
•
Do not remove any of the attached metal plates, which
contain important safety and operating information.
Keep the appliance area clear and free of all combustible
materials, gasoline and other flammable vapors and
liquids.
WARNING
Fire Risk
High Temperatures
Keep combustible household items away
from appliance.
Do NOT obstruct combustion and ventilation
air.
WARNING
•
Do NOT place combustible items on top
of or in front of appliance.
Do NOT use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
•
Keep furniture, draperies away from
appliance.
12
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintaining and Servicing the Appliance
6
A. Servicing Your Appliance
C. Annual Inspection
WARNING
WARNING
Risk of injury or property damage
Before servicing:
Annual inspection by qualified technician
recommended.
Check:
•
•
•
•
Turn off gas.
•
•
Condition of doors, surrounds and fronts.
Obstructions of combustion and ventilation
air.
Turn off electricity to appliance.
Disable remote control, if one is present.
Ensure appliance is completely cooled.
•
•
•
•
Condition of logs.
Condition of firebox.
Gas connections and fittings.
Obstructions of termination cap.
After Servicing:
•
•
Replace any screen or barrier that was removed.
Reseal and reinstall any venting removed for
servicing.
Clean:
•
•
•
Glass.
Logs.
Burner, burner ports.
•
•
Repair and replacement work should be done by a
qualified service technician.
Alwaysshutoffthegassupplyandmakesuretheappliance
is cool before beginning any service operation.
Always check for gas leaks after servicing.
Always check for proper venting.
Risk of:
•
•
•
•
Fire
Delayed ignition or explosion
Exposure to combustion fumes
Odors
•
•
B. Cleaning Your Appliance
Your gas logs require little care. Keep the burner assembly,
logs and burner area surrounding the logs clean by
vacuuming or brushing with a dry paint brush at least twice
a year.
D. Troubleshooting
With proper installation and maintenance, your new
decorative gas appliance should provide years of trouble-
free service. If you do experience a problem, refer to the
troubleshooting guide below. This guide will assist you or a
qualified service technician in the diagnosis of problems and
the corrective action to be taken.
•
The logs become fragile after burning. Take care in
handling.
•
Always turn off the gas before cleaning. For relighting,
refer to lighting instructions located in Section 5.A. of these
instructions.
Symptoms
Possible Causes
Corrective Action
•
•
Always keep the appliance clear and free from combustible
materials, gasoline, and other flammable vapors and
liquids.
Never obstruct the flow of combustion and ventilation air.
Keep the front of the appliance clear of all obstacles and
materials.
1. A match will
not light the
A. Main gas shutoff
valve is closed
1. Make sure the shutoff
valve located on the
incoming gas line is
open.
main burner;
no gas to the
main burner
B. There is air in the
gas line.
1. Bleed air from the gas
line; wait five minutes
and attempt to relight
the main burner.
•
•
Leave clearance of at least 36 in. from the front of the
fireplace.
The air shutter should not be blocked.
C. No gas supply to
the appliance.
1. Check the plumbing to
ensure the appliance
has been hooked up
to the gas supply line.
CAUTION
•
Logs can get very hot. Handle only when they are
cool.
D. A blockage is
1. Inspect the burner
orifice for obstruction.
Call a qualified
preventing gas flow.
service technician.
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference Materials
7
A. Replacement Parts
Service Parts
Fireside HeartH Kits
Exploded Parts Diagram
MHK-NG
Beginning Manufacturing Date:8/1/2010
Ending Manufacturing Date: Active
TM
1 - MHK Burner Pan Assembly
2 - MHK Grate Assembly
MHK Hearth Kit Assembly
7
5
8
3
6
4
14
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Parts
Fireside HeartH Kits
Service Parts List
MHK -NG
Beginning Manufacturing Date:8/1/2010
Ending Manufacturing Date: Active
TM
#
Description of Part
Burner Pan Assy
Grate Assy
MHK18NG
MHK24NG
Qty.
1
1
SRVAGLBP14 SRVAGLBP18
2
3
4
5
6
7
8
SRVAG16
BPO-2-26
SRVAG18
BPO-2-20
1
Orifice
1
Connector Tube
Damper Stop Assy
SRV3814NXN SRV3814NXN
1
SRV500-SC
01-1050
SRV500-SC
01-1050
1
Elbow, 3/8” MFL x 3/8” FPT Brass
Elbow, 3/8” Flare x 1/2” FIP Brass
Cap, 1/2” Malleable Pipe
Sand
1
10-1037
10-1037
1
10-1053
10-1053
1
SRVACC15
SRVACC10
SRVACC12
SRVACC15
SRVACC10
SRVACC12
1
Lava Rock
1
Glowing Embers
1
Hearth Kit Install
4004-304
4004-304
1
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Parts
Fireside HeartH Kits
Exploded Parts Diagram
STMHK-NG
Beginning Manufacturing Date:8/1/2010
Ending Manufacturing Date: Active
TM
1 - STMHK Burner Pan Assembly
2 - STMHK Grate
5
7
3
6
4
16
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Parts
Fireside HeartH Kits
Service Parts List
STMHK -NG
Beginning Manufacturing Date:8/1/2010
Ending Manufacturing Date: Active
TM
#
Description of Part
Burner Pan Assy
Grate Assy
STMHK18NG
STMHK24NG Qty.
1
SRVOBP18ST SRVOPB20ST
1
1
1
1
1
1
1
1
1
1
2
3
4
5
6
7
SRVAG16
BPO-2-26
SRVAG18
BPO-2-20
Orifice
Connector Tube
Damper Stop Assy
SRV3814NXN SRV3814NXN
SRV500-SC
01-1050
SRV500-SC
01-1050
Elbow, 3/8” MFL x 3/8” FPT Brass
Elbow, 3/8” Flare x 1/2” FIP Brass
Sand
10-1037
10-1037
SRVACC15
SRVACC10
SRVACC12
SRVACC15
SRVACC10
SRVACC12
Lava Rock
Glowing Embers
Hearth Kit Install
4004-304
4004-304
1
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
17
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-304 Rev C • 08/2010
19
Download from Www.Somanuals.com. All Manuals Search And Download.
C. Contact Information
TM
Please contact your Hearth & Home Technologies dealer with any questions or concerns.
For the number of your nearest Hearth & Home Technologies dealer, please call 1-800-927-6841 or 1-888-427-3973.
- NOTES -
CAUTION
DO NOT DISCARD THIS MANUAL
•
Read, understand
and follow these
instructions for safe
installation and
operation.
•
Leave this manual with
party responsible for
use and operation.
•
Important operating
and maintenance
instructions included.