Harman Stove Company Stove 929BV User Manual

installation & operating Manual  
The harman Clarity 929bv gas Stove  
“Ce manuel est disponible en Français sur demande”  
R5  
SAFETY NOTICE  
PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr. FAIlurE  
TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh.  
IF ThIS hArmAN STOvE IS NOT PrOPErlY INSTAllEd, A hOuSE FIrE mAY rESulT. FOr YOur SAFETY, FOl-  
lOw INSTAllATION dIrECTIONS.  
CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT rESTrICTIONS ANd INSTAllATION INSPECTION  
rEQuIrEmENTS IN YOur ArEA.  
CONTACT YOur lOCAl AuThOrITY (SuCh AS muNICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT, FIrE  
PrEvENTION burEAu, ETC.) TO dETErmINE ThE NEEd FOr A PErmIT.  
CETTE guIdE d'uTIlISATION EST dISPONIblE EN FrANCAIS. ChEz vOTrE CONCESSIONNAIrE dE hArmAN  
STOvE COmPANY.  
whAT TO dO IF YOu SmEll gAS  
• dO NOT TrY TO lIghT ANY APPlIANCE.  
• dO NOT TOuCh ANY ElECTrICAl SwITCh; dO NOT uSE ANY PhONE IN YOur buIldINg.  
• ImmEdIATElY CAll YOur gAS SuPPlIEr FrOm A NEIghbOr'S PhONE. FOllOw ThE gAS SuPPlIEr'S  
INSTruCTIONS.  
• IF YOu CANNOT rEACh YOur gAS SuPPlIEr, CAll ThE FIrE dEPArTmENT.  
save these instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction.  
Several.issues.must.be.addressed.when.selecting.a.  
suitable.location.for.your.Clarity.Gas.Heater..Observ-  
ing.required.clearances.to.combustible.materials,.the.  
proximity.to.a.safe.chimney.or.venting.system,and.  
the.accessibility.of.the.gas.and.electrical.supply.must.  
all.be.considered..In.addition,.selecting.a.location.that.  
takes advantage of the building's natural air flow is  
also.desirable.to.maximize.the.heating.effectiveness.  
of.the.heater..In.many.cases,.this.is.a.central.location.  
within.the.building.  
The.Harman.Clarity.929BV.Vented.Gas.Heater.is.a.  
listed gas-fired vented room heater tested by Intertek  
Testing/Warnock.Hersey.to.ANSI.standard.Z21.88-  
2002,.CSA.2.33-M02,.and.CAN/CGA-2.17-M91..  
The.installation.of.the.Clarity.Vented.Gas.Heater.  
must.conform.with.local.codes,.or.in.the.absence.of.  
local.codes,.with.the.current.edition.of.National.Fuel.  
Gas.Code,.ANSI.Z223.1..latest.edition.and.CAN.  
1-B1-149.1.and..2.Installation.Code..  
The.Clarity.929BV.is.not.for.use.in.mobile.homes.  
CaUTIon: This.appliance.must.be.vented.to.the.  
outside..  
Adequate.combustion.and.ventilation.air.must.be.  
provided.  
Installation.and.repair.of.the.Clarity.Vented.Gas.  
Heater should be done by a qualified service person.  
The.appliance.should.be.inspected.before.use.and.at.  
least annually by a qualified service person. More fre-  
quent.cleaning.may.be.required.due.to.excessive.lint.  
from.carpeting,.bedding.material,.etc..It.is.imperative.  
that.control.compartments,.burners,.and.circulating.air.  
passageways.of.the.Clarity.be.kept.clean..  
When.operating.your.Harman.Clarity.Gas.Heater,.  
respect.basic.safety.standards..Read.these.instructions.  
carefully.before.you.attempt.to.operate.the.heater..  
Failure.to.do.so.may.result.in.damage.to.property.or.  
personal.injury.and.may.void.the.product.warranty..  
Consult.with.your.local.building.code.agency.and.  
insurance.representative.before.you.begin.your.instal-  
lation.to.ensure.compliance.with.local.codes,.including.  
the.need.for.permits.and.follow-up.inspections..  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Due to high temperatures, the Clarity Vented Gas  
Heater should be located out of traffic and away  
from furniture and draperies.  
Children and adults should be alerted to the haz-  
ards of high surface temperatures and should stay  
away to avoid burns or clothing ignition.  
Young children should be carefully supervised  
when they are in the same room as the Clarity  
Vented Gas Heater.  
Clearance from corner of unit to walls  
Clothing or other flammable materials should  
not be placed on or near the Clarity Vented Gas  
Heater.  
INSTALLATION  
CleaRanCes  
The.following.clearances.to.combustibles.must.be.  
observed:  
Unit.to.left.sidewall.  
Unit.to.right.sidewall.  
Unit.corner.to.walls.  
Rear.of.unit.to.back.wall.  
9".. (230.mm)  
9".. (230.mm)  
4".. (100.mm)  
3".. (75.mm)  
Clearance to alcove ceiling  
(measured.from.rear.of.draft.hood.to.wall)  
Unit.to.alcove.ceiling.  
Maximum.alcove.depth.  
18".. (460.mm)  
14".. (355.mm)  
Maximum alcove depth  
Sidewall Clearance  
In.addition.to.these.clearances,.adequate.accessibil-  
ity.clearance.for.servicing.and.proper.operation.must.be.  
maintained.  
Do.not.in.any.way.obstruct.the.combustion.air.inlets.  
that.are.located.under.the.heater.  
If.this.appliance.is.installed.directly.on.carpeting,.tile.  
or other combustible material other than wood flooring the  
appliance.shall.be.installed.on.a.metal.or.wood.panel.ex-  
tending.at.least.the.full.width.and.depth.of.the.appliance.  
Clearance to Back wall  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VenTInG  
WARNING: Operation of this heater when not con-  
nected to a properly installed and maintained venting  
system or tampering with the vent safey shutoff system  
can result in carbon monoxide (Co) poisoning and pos-  
sible death.  
The.Clarity.gas.heater.is.equipped.with.its.own.internal.  
draft.hood.so.no.additional.external.draft.hood.is.required..  
The.heater.should.be.installed.so.that.the.draft.hood.is.in.  
the.same.atmospheric.pressure.zone.as.the.air.inlets.to.the.  
heater.  
Use Only Approved Venting  
The.Clarity.gas.heater.is.tested.and.listed.for.connection.  
to.a.4".(100.mm).listed.Class.B.venting.system..  
If.the.unit.is.installed.to.vent.through.an.approved.masonry.  
chimney.or.a.factory-built.chimney.system,.an.approved.  
Class.B.chimney.liner.must.be.used..  
Observe.local.codes.when.venting.the.Clarity..If.no.local.  
codes.exist,.follow.the.current.edition.of.ANSI.Z223.1.and.  
CAN1-.B149.installation.codes..  
Do not connect the venting to the flue of a chimney that  
serves.a.separate.solid-fuel.burning.appliance.  
The.venting.manufacturer's.installation.instructions.must.  
be.followed.exactly.  
TesT foR flUe sPIllaGe  
A.spillage.test.should.always.be.made.at.the.completion.  
of.the.installation.  
IMPORTANT: Because of the high efficiency and low  
flue gas temperatures of this appliance, it is important that  
it be connected to a well-sealed and efficient venting system  
which.is.capable.of.registering.a.negative.pressure.while.  
the.stove.is.in.operation.  
1..Start.all.exhaust.fans.in.the.home.and.then.close.all.  
doors.and.windows.in.the.room.containing.the.heater.  
2..Light.the.heater.and.allow.it.to.run.for.5.minutes.on.the.  
high.output.setting..If.the.convection.air.blower.is.installed,.  
it.should.be.turned.off.for.the.test.  
The most efficient venting systems are those that have a  
minimum.number.of.bends.and.minimal.horizontal.runs.  
The.Clarity.gas.heater.is.equipped.with.a.thermally.acti-  
vated.vent.safety.switch.that.will.shut.down.the.main.burner.  
if.the.heater.is.not.properly.venting..The.safety.switch.will.  
automatically.reset.after.the.heater.has.cooled.down.  
The.switch.will.continue.to.cycle.off.and.on.until.the.  
venting.problem.is.corrected..If.you.are.unable.to.correct.  
the.venting.problem,.seek.expert.advice.from.your.Harman.  
dealer.or.installer.  
3..Hold.a.match.or.other.source.of.smoke.near.the.draft.  
hood.outlet.on.the.upper.back.of.the.stove..  
4..If.the.smoke.is.not.drawn.in,.turn.off.the.heater.and.  
determine.the.cause.of.the.lack.of.draft..If.necessary,.seek.  
expert.advice.  
For.sites.with.swirling.or.turbulent.wind.conditions,.a.  
wind.cap.may.solve.the.problem.  
Do noT DIsConneCT oR bYPass THe VenT  
safeTY sWITCH.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
asseMblY  
The.Clarity.is.shipped.from.the.factory.with.the.log.set.  
packed inside the firebox. To prepare the stove for installa-  
tion,.the.log.set.must.be.unpacked,.the.appropriate.burner.  
system.module.for.either.natural.gas.or.propane.installed,.  
and.the.logs.installed.  
1
2
Removing the Glass Front  
NOTE:.The.glass.front.is.heavy..Be.prepared.for.its.  
weight.when.lifting.it.to.avoid.damage.during.removal.  
The.wing.doors.on.each.side.are.held.closed.by.magnets..  
Push.on.each.door.to.open.it..Loosen.the.wing.nut.on.each.  
of.the.two.levers..Grasp.each.lever.and.push.to.the.rear.to.  
disengage.the.front..To.keep.the.levers.in.the.disengaged.  
position,.tighten.the.wing.nuts..Lift.the.glass.front.slightly.  
and.remove.it.from.the.stove..Set.the.glass.aside.in.a.safe.  
place.where.it.will.not.be.damaged.  
WaRnInG: Do not abuse the Clarity's glass by  
striking, slamming, or similar trauma. Do not oper-  
ate the Clarity Vented Gas Heater with the glass panel  
removed,  
4
3
The.log.set.components.are.shipped.from.the.factory.  
individually.wrapped.and.packed.inside.the.stove..Take.them.  
out.of.the.stove,.then.carefully.remove.the.wrapping..Handle.  
the.logs.gently.as.they.may.be.damaged.easily.  
The.front.is.released.when.  
levers.on.the.left.and.  
right.sides.are.pushed.to.  
the.rear  
cracked or broken. Use only glass supplied by Harman  
and approved for use with this heater. Do not use substi-  
tute materials. Replacement of the panel should be done  
by a licensed or qualified service person.  
Remove and Unwrap the Log Set  
As.shown.in.the.photo.above.right,.the.log.set.consists.  
of.a.back.log.(1),.a.center.log.that.has.a.pilot-viewing.port.  
in.the.left.end.(2),.ember.strip.(3),.and.a.branch.that.rests.on.  
top.(4)..  
In.addition,.there.are.two.side.brick.panels.and.a.back.  
brick.panel.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install the Back Log and Back Brick Panel  
These.two.components.are.installed.as.a.single.piece..  
Rest.the.back.brick.panel.on.the.shelf.located.on.the.back.  
side.of.the.back.log,.and.center.it..Holding.the.two.pieces.  
as.a.single.unit,.tilt.the.top.forward.slightly.and.manuever.  
it.over.the.top.of.the.rear.burner—taking.care.that.the.top.  
corners.clear.the.front.opening..Place.it.snugly.against.the.  
back.wall.and.center.it.  
Install the Side Brick Panels  
These.slide.into.place.along.each.side.and.are.held.by.  
friction..The.notch.in.each.panel.faces.the.back..Install.one.  
side,.and.then.the.other.  
Install the Ember Strips  
The ember strips rest against the front of the firebox and  
should fit snugly. Guide them toward you and to the outside  
until they fit snugly. Check the air slot in the inside of the  
ember strips to confirm that they do not obstruct it.  
Install the Center Log  
The.center.log.goes.all.the.way.to.the.back.and.should.  
be.centered..When.properly.positioned,.there.should.be.an.  
even.gap.along.the.front.of.the.center.burner.in.the.cavity.  
in.the.log..A.small.portion.of.the.log.support.frame.will.be.  
revealed.  
The.center.log.has.a.round.viewing.port.in.the.left.end.  
through.which.the.pilot.can.be.observed.  
Install the Branch  
Orient.the.branch.with.the.forked.end.toward.the.left.rear.  
of.the.stove.and.slip.it.over.the.two.locator.pins,.one.on.top.  
of.the.back.log.and.the.other.on.the.top.of.the.center.log.  
Secure the Glass Front  
NOTE:.The.glass.front.is.heavy..Lift.it.carefully.to.pre-  
vent.damage..Center.the.glass.on.the.opening.and.suspend.  
it.in.place.by.placing.the..the.tab.hooks.over.the.top.edge.  
of.the.opening..Loosen.the.wing.nuts.that.hold.the.spring-  
loaded.levers.in.place..Press.the.glass.slightly.against.the.  
stove to confirm that it seats properly, then press it firmly  
against.the.front.while.pulling.the.levers.forward.to.engage.  
them..Tighten.the.wing.nuts..  
The.complete.log.set,.with.the.logs.installed.and.positioned.correctly.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConneCTInG THe HeaTeR  
To a Gas sUPPlY  
natural Gas:  
Maximum. inlet. pressure. 7.0". w.c.. (1.74. kPa).  
Minimum. inlet. pressure. 5.0". w.c.. (1.25. kPa).  
Gas.manifold.pressure.3.5".w.c..(0.87.kPa)  
Burn Only the Fuel for which the Heater is Equipped  
The.Clarity.B-Vent.will.burn.either.natural.gas.or.pro-  
pane,.but.requires.a.dedicated.burner.system.module.for.  
either.fuel..The.label.on.the.burner.system.module.indicates.  
the.fuel.for.which.it.is.equipped..A.second.label,.located.near.  
the.rating.plate,.also.indicates.the.fuel.type.  
lPG Gas:  
Maximum. inlet. pressure. 13". w.c.. (3.24. kPa).  
Minimum. inlet. pressure. 11". w.c.. (2.74. kPa).  
Gas.manifold.pressure.10".w.c..(2.49.kPa)  
DO.NOT.USE.THIS.HEATER.IF.ANY.PART.HAS.  
BEEN.UNDER.WATER.OR.EXPOSED.TO.MOISTURE.  
CORROSION.. IMMEDIATELY. CALL.A. QUALlFlED.  
SERVICE.TECHNICIAN.TO.INSPECT.THE.HEATER.  
AND.REPLACE.ANY.PART.OF.THE.CONTROL.SYS-  
TEM.AND.ANY.GAS.CONTROL.WHICH.HAS.BEEN.  
UNDER.WATER.  
NATURAL GAS  
PROPANE  
RECOMMENDED.GAS.PIPE.DIAMETER  
Pipe.Length.  
(Feet).  
Schedule.40.Pipe.  
Inside.Diameter.  
Tubing,.Type.L  
Outside.Diameter  
N.G..  
L.P..  
N.G..  
L.P.  
0-10.  
.
1/2".  
1.3.cm.  
3/8".  
1.0.cm.  
1/2".  
1.3.cm.  
3/8"  
1.0.cm  
10-40.  
.
1/2".  
1.3.cm.  
1/2".  
1.3.cm.  
5/8".  
1.6.cm.  
1/2"  
1.3.cm  
40-100.  
.
1/2".  
1.3.cm.  
1/2".  
1.3.cm.  
3/4".  
1.6.cm.  
1/2"  
1.3.cm  
100-150.  
.
3/4".  
2.0.cm.  
1/2".  
1.3.cm.  
7/8".  
2.3.cm.  
3/4"  
2.0.cm  
Making The Connection  
The.gas.inlet.is.located.at.the.bottom.right.rear.of.the.stove..  
The inlet fitting is a 1/2" female flare flexible pipe.  
A.separate.gas.shut-off.valve.and.a.1/8".N.P.T..plugged.  
tapping.should.be.installed.immediately.upstream.of.the.  
connection.to.the.appliance.  
NOTE:.NEVER.USE.PLASTIC.PIPE..CHECK.TO.CONFIRM.  
WHETHER.YOUR.LOCAL.CODES.ALLOW.COPPER.TUBING.  
OR.GALVANIZED.PIPE.  
The.Clarity.B-Vent.Gas.Heater.must.be.disconnected.from.  
the.gas.supply.piping.during.any.pressure.testing.of.that.  
system.at.pressures.in.excess.of.1/2.psig.(3.5.kPa).  
The.Clarity.gas.control.valve.must.be.in.the.OFF.position.  
during.any.pressure.testing.of.the.gas.supply.system.at.pres-  
sures.equal.to.or.less.than.1/2.psig.(3.5.kPa).  
WARNING: To avoid pipe compounds from entering  
into the gas train, apply compounds only to the male pipe  
threads and only to the first two threads.  
Whether or not you have installed a conversion kit, fill  
out.the.installer.fuel.label,.on.the.stove,.or.the.one.that.was.  
included with the conversion kit, and affix it to the stove  
in.the.appropriate.location..  
CAUTION:.TEST.ALL.JOINTS.FOR.LEAKS.BEFORE.  
OPERATING.  
Gas Pressure Requirements  
Correct.gas.pressure.and.the.use.of.a.properly.sized.  
gas supply line are essential for the safe and efficient per-  
formance.of.this.appliance..Make.sure.that.the.plumber.or.  
gas.supplier.checks.the.gas.supply.line.and.gas.pressure.at.  
installation.  
.NOTE:.Improper.gas.pressure.can.affect.heater.perfor-  
mance, flame color, or cause pilot outage.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConneCTInG THe CoRDseT  
The.Clarity.B-Vent.Gas.Heater.must.be.installed.in.ac-  
cordance.with.local.codes.or,.in.the.absence.of.local.codes,.  
with.the.most.recent.edition.of.the.National.Electrical.Code.  
ANSI/NFPA.70,.or.the.current.Canadian.Electrical.Code.  
C22.1.  
NOTE:.The.convection.fan.requires.a.120.VAC.supply.  
for.operation,.but.the.heater.can.be.operated.without.the.fan.  
as.in.the.case.of.a.power.outage.  
Terminal.strip.for.  
thermostat.connec-  
tion  
Plug.the.3-prong.grounded.electrical.cord.plug.into.  
the.wall.  
Rear.view.of.Clarity  
ConneCTInG THe  
oPTIonal THeRMosTaT  
If.connecting.the.optional.thermostat,.it.must.be.plugged.  
into.the.terminal.strip.located.on.the.left.side.near.the.bot-  
tom.of.the.stove.  
When. installing. a. millivolt. control. sys-  
tem,. use. only. a. special. low. resistance. thermostat..  
Do.not.use.a.regular.heating.thermostat.  
WaRnInG: THIs HeaTeR Is eqUIPPeD WITH  
a THRee-PRonGeD GRoUnDInG PlUG THaT  
sHoUlD be PlUGGeD DIReCTlY InTo a PRoP-  
eRlY GRoUnDeD ReCePTaCle. Do noT CUT  
oR ReMoVe THe GRoUnDInG PRonG fRoM  
THe PlUG.  
Be.sure.that.all.electrical.connections.are.clean,.free.  
from.corrosion,.and.tight..Inspect.connections.periodically.  
to confirm that no corrosion has built up over time.  
When.properly.installed.and.maintained,.a.millivolt.  
control. system. should. give. many. years. of. trouble-free.  
service.  
It.is.important.to.use.wire.of.a.gauge.proper.for.the.  
length.of.the.wire:  
ReCoMMenDeD WIRe GaUGes  
.
Maximum .  
Length  
100'.  
Wire  
Gauge.  
14.  
16.  
18  
.
.
.
.
.
60'.  
40'.  
25'.  
15'.  
20  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
aIR sHUTTeR aDJUsTMenT  
MonIToRInG THe Gas flaMe  
The final step of the installation is to check the flame  
pattern,.which.should.resemble.the.pattern.illustrated.in.the.  
right column: The flames should be relatively well-defined  
and.stable..They.should.be.bright.yellow.with.a.blue.base.  
where.attached.to.the.burner.ports,.and.should.not.look.  
orange.or.sooty...  
Start.the.heater.according.to.the.directions.on.page.11.and.  
allow.the.heater.to.burn.for.approximately.15.minutes..The.  
flames will increase in length and become more yellow in  
color.as.the.Clarity.heats.up.  
Periodically, the flames of the Clarity B-Vent Gas Heater  
should be checked while it is operation. The flames should  
be relatively well-defined and stable. They should be bright  
yellow.with.a.blue.base.where.attached.to.the.burner.ports..  
The flames should not look orange or sooty. Portions of the  
logs will glow red when the flames are properly adjusted.  
If you find the flames to be other than that described here,  
do not operate the heater. Consult a qualified service person  
or.your.Harman.dealer.for.advice...  
If the flames do not resemble the description above and  
the illustration in the right column, the air shutters may be  
adjusted.  
Three.separate.screws—one.for.each.burner—are.used.to.  
adjust the flames for a particular installation. Two of them  
are.accessible.through.the.side.access.port.on.the.right.side.  
of.the.stove..The.third.is.accessible.from.the.front.when.the.  
control.door.is.open..The.screws.may.become.hot.to.the.  
touch.after.prolonged.operation..Use.a.3/16".Allen.wrench.  
to avoid contact if hot. For best results when fine-tuning the  
flame picture, initially leave the middle screw unchanged  
from.its.factory.setting..Turn.the.other.two.screws.as.needed.  
to increase or decrease the brightness and length of the flame:  
turning counterclockwise will increase the flame; turning  
clockwise will decrease the flame.  
The Clarity flame pattern will resemble this when the unit is  
burning properly.  
1..To.adjust.the.rear.burner,.open.the.right.wing.door,.  
reach.through.the.side.access.port,.and.turn.the.rear.screw.  
to adjust flame (see directions above).  
2. To adjust the front burner, first open the control door,  
then turn the front screw to adjust flame (see directions  
above)..  
The properly-burning pilot  
will resemble the illustration  
to the right.  
Repeat procedure as needed until desired flame effect is  
achieved.  
Rear.burner.  
Air adjustment screws  
Center.burner.  
Front.burner.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
HoW To lIGHT THe fIRe  
1...STOP!..Read.the.safety.information.on.the.left.side.  
of.the.panel.below.  
2...If.using.the.optional.thermostat,.set.thermostat.to.the.  
lowest.setting.  
3...Turn.off.electric.power.to.the.appliance.  
4...Turn.the.ON-OFF/THERMOSTAT.switch.to.the.OFF.  
position.  
..•If.the.knob.does.not.pop.up.when.released,.stop.and.  
immediately.call.your.service.technician.or.gas.supplier.  
..•If.the.pilot.will.not.stay.lit.after.several.tries,.turn.the.  
gas.control.knob.to."OFF".and.call.your.service.technician.  
or.gas.supplier.  
11.. .Turn. the. gas. control. knob. counterclockwise.to.  
"ON."  
5.. . Push. in. the. gas. con-  
trol. knob. slightly. and. turn.  
it. clockwise. to. "OFF.".  
12...Place.the.ON-OFF/THERMOSTAT.switch.in.the.ON.  
position.or.in.the.THERMOSTAT.position.if.the.optional.  
thermostat.is.used.  
NOTE:..The.knob.cannot.be.  
turned.from."PILOT".to."OFF".  
unless.it.is.pushed.in.slightly...Do.  
13...Turn.on.the.electric.power.to.the.heater.  
14...Set.the.optional.thermostat.to.the.desired.room.tem-  
perature.  
not.force.it...  
15..Set.the.High-Low.Regulator.to.desired.setting:.turn.  
fully.counterclockwise.for.High.and.fully.clockwise.for.  
Low.  
NOTE:.An.odor.resulting.from.the.initial.heating.of.new.  
materials in your heater is not unusual during the first fire,  
and.in.most.cases.will.disappear.after.an.hour.or.two.  
6. Wait five (5) minutes to clear out any gas. If you then  
smell.gas,.STOP!..Follow."B".in.the.safety.information.on.  
the.label.below..If.you.don't.smell.gas,.go.to.the.next.step.  
7..Set.the.High-Low.Regulator.to.High.by.turning.it.fully.  
counterclockwise.  
8...Press.in.the.gas.control.knob.slightly.and.turn.coun-  
terclockwise.to."PILOT."  
9...Find.the.pilot.by.looking.through.the.round.opening.  
on.the.left.end.of.the.center.log.  
10...Push.the.control.knob.fully.down.and.hold..Immedi-  
ately.push.the.red.piezo.ignitor.button.to.light.the.pilot..It.is.  
normal.to.have.to.push.the.red.button.several.times.before.  
the.pilot.ignites..Continue.to.hold.the.control.knob.in.for.  
about.one.(1).minute.after.the.pilot.is.lit...Release.the.knob.  
and.it.will.pop.back.up...Pilot.should.remain.lit..If.it.goes.  
out,.repeat.steps.5.through.9.  
HoW To TURn off THe fIRe  
1...If.using.optional.thermostat,.set.thermostat.to.the.low-  
est.position.  
2...Turn.off.the.electric.power.to.the.appliance.  
3...Turn.the.ON-OFF/THERMOSTAT.switch.to.the.OFF.  
position.  
4...Push.in.the.gas.control.knob.slightly.and.turn.it.clock-  
wise.to.“OFF.”  
NOTE:..The.knob.cannot.be.turned.from.PILOT”.to.  
“OFF”.unless.it.is.pushed.in.slightly..Do.not.force.it.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CleanInG THe loG seT anD fIRebox  
During.the.annual.inspection.and.maintenance.appoint-  
ment,.the.service.person.should.clean.dust,.lint,.and.any.  
light accumulation from the logs and the firebox area.  
An.extra-soft.brush.should.be.used.on.the.logs.as.they.  
are extremely fragile; a vacuum cleaner may be used on  
the firebox. If at any time the logs cannot be removed or  
installed.without.forcing,.the.cause.must.be.found..The.  
logs.must.never.be.forced.  
Maintenance  
A qualified service person recommended by your  
Harman.dealer.should.conduct.an.annual.inspection.and.  
maintenance.of.your.Clarity,.its.venting,.and.the.installa-  
tion to keep it running safely and efficiently. These pro-  
cedures should be performed only by a qualified service  
person..The.gas.supply.should.be.turned.off.whenever.a.  
maintenance.procedure.is.performed.  
If.the.front.panel,.side.doors,.or.front.access.door.are.  
removed.for.servicing,.they.must.be.replaced.prior.to.  
operating.the.Clarity.  
Removing the Front  
See.directions.on.page.6.  
Removal and Re-installation of the Log Set for Cleaning  
CAUTION:.The.ceramic.logs.are.durable.when.  
handled.and.installed.properly..However,.they.are.deli-  
cate.and.may.be.damaged.easily.if.not.handled.with.care..  
Handling.damage.to.the.ceramic.logs.is.not.covered.by.  
warranty.  
DO.NOT.HANDLE.LOGS.WHILE.THEY.ARE.  
HOT..ALLOW.PLENTY.OF.TIME.FOR.THE.STOVE.  
TO.COOL.COMPLETELY.BEFORE.HANLDING.  
ReMoVInG THe Glass fRonT  
foR RePlaCeMenT  
Refer.to.page.6.for.directions.on.removing.the.glass.  
front..Use.only.authorized.Harman.replacement.glass.  
components.available.from.your.dealer.  
RePlaCInG THe GaskeT  
The Clarity has 5/8" diameter fiberglass gasket in the  
front.door..Should.it.ever.need.replacement,.use.only.the.  
proper.replacement.gasket.that.is.available.from.your.  
Harman.dealer..To.replace.the.gasket,.follow.this.proce-  
dure.  
1..Open.the.door  
2..Remove.the.existing.gasket.and.clean.its.channel.  
with.a.scraper.or.wire.brush.  
Remove the Branch  
Detach.the.branch.from.the.two.locator.pins.and.re-  
move.it..Brush.it.gently.and.carefully.place.it.to.one.side.  
Remove the Center Log  
Lift.the.center.log.and.remove.it..Brush.it.gently.and.  
carefully.place.it.to.one.side.with.the.branch.  
Remove the Ember Strips  
Carefully.remove.the.ember.strips,.clean.them,.and.  
place.them.with.the.other.logs.  
3..Lay.a.thin.bead.of.high.temperature.silicone.the.  
entire.length.of.the.channel.  
4. Lay the gasket in the channel with sufficient pressure  
that.is.stays.in.place.  
Remove the Side Brick Panels  
Carefully remove first one side panel, and then the  
other..Clean.and.place.to.side.  
5..Trim.the.excess.from.the.end.of.the.gasket.so.that.it.  
butts.snugly.against.the.other.end.without.leaving.a.gap..  
Seal.the.end.joint.with.high.temperature.silicone.  
6. Close the door and apply firm pressure to seat the  
gasket.evenly.throughout.  
Remove the Back Log and Back Brick Panel  
Finally,.carefully.remove.these.two.components.as.a.sin-  
gle.piece..Brush.them.gently.and.place.them.to.the.side.  
Finish.the.procedure.by.vacuuming.the.interior.of.the.  
firebox, then re-install the logs and secure the glass front  
following.the.procedures.on.page.7.  
CleanInG THe Glass  
The.glass.may.be.cleaned.with.ordinary.household.  
glass.cleaner.and.a.soft.cloth.or.paper.towel.  
WARNING: Never clean the glass when it is hot. Do  
not use abrasive cleaners on the glass.  
InsPeCTInG THe VenTInG  
An.inspection.of..the.venting.system.should.be.made.  
during.the.annual.service.appointment..The.system.must.  
have.no.blockage.and.must.be.in.good.repair..The.vent.  
manufacturer's instructions may provide specific sugges-  
tions.or.details.on.vent.inspection..Any.sections.that.are.  
taken.apart.for.the.inspection.must.be.reassembled.and.  
sealed.as.required.  
1ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Clarity B-Vent gas heater, when installed, must be electri-  
cally grounded in accordance with local codes or, in the absence  
of local codes, with the current edition of the National Electri-  
cal Code, ansI/nfPa 70 in the United states or the current  
Canadian electrical Code Csa 22.1 in Canada.  
1ꢁ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts.List  
The.following.replacement.parts.for.your.Harman.Clarity.B-Vent.are.available.from.your.Harman.dealer.  
ID# Part no.  
Part  
39. 3-40-08230.  
40. 3-40-08228.  
41. 3-40-08220.  
42. 3-31-08282.  
Pilot,.LP  
1.  
2.  
3.  
4
1-89-08270.  
BVG.weldment  
Left.wing.door  
Thermocouple  
1-10-08262-1.  
1-10-08262-2.  
3-40-08286  
3-40-08235.  
3-40-08236.  
3-40-08237.  
3-40-08401.  
3-40-08232.  
Piezo.ignitor  
Right.wing.door  
1/2" gas inlet flex  
Rear.log  
90°.brass.elbow  
43  
44  
3-31-08283  
3-31-08284  
1/4" tp 3/8" male compression fitting  
3/8" tp 3/8" male compression fitting  
5.  
6.  
7.  
8.  
9.  
Front.log  
45. 3-30-310056082. BHSCS.5mm.X.8mm.for.valve  
Top.log  
46. 3-20-326006.  
47. 3-20-326005.  
48. 3-20-08221.  
49. 3-20-08219.  
50. 2-00-08281.  
51. 0-46-250.  
18".valve.harness  
Harness.w/VSC  
Ember.strip  
Left.brick.panel  
Right.brick.panel  
Rear.brick.panel  
Front.burner.tube  
Center.burner.tube  
Rear.burner.tube  
Ext..spring  
On-Off.rocker.switch  
Thermopile  
10. 3-40-08233.  
11. 3-40-08234.  
12. 3-40-08224.  
13. 3-40-08225.  
14. 3-40-08226.  
15. 3-31-965487.  
16. 3-40-00141.  
17. 3-31-08225.  
18. 3-20-408412.  
19. 2-00-4213.  
20. 3-20-326004.  
21. 2-00-4177.  
22. 3-42-2312.  
23. 3-44-1086405.  
24. 3-43-4103.  
25. 3-40-120.  
3/8".tubing  
1/4".tubing  
52. 1-00-08513.  
53. 1-00-08314.  
54. 3-20-408411.  
55. 2-00-42208.  
56a. 2-00-42220.  
56b. 2-00-42219.  
57. 2-00-4169.  
58. 1-10-08265-1.  
59a. 1-10-08265-2.  
60a. 2-00-4138-1.  
60b. 2-00-4138-2.  
61. 1-10-08287.  
62. 1-10-08258.  
63. 2-00-42217.  
64. 2-00-4162.  
65. 2-00-4210.  
Valve.change-over.assembly,.NG  
Valve.change-over.assembly,.LP  
Snap.disc.safety.switch  
Rear.cover  
Formed.wire.gold.trim  
Magnet  
Snap.disc.safety.switch.bracket  
Snap.disc.safety.switch.heat.shield  
Base.trim  
Snap.disc.fan.control  
Snap.disc.fan.control.bracket  
Power.cord  
Latch.arm,.left  
Lower.rear.access.cover  
Glass.gasket  
Latch.arm,.right  
Latch.cam,.left  
5/8".tight.knit.rope.for.door  
Gold.plated.door.frame  
13-3/4".X.19".glass  
5-3/4".X.13-3/4".glass  
Distribution.blower.w/ends  
Pilot.tower.gasket  
NG.valve  
Latch.cam,.right  
Front.door.assembly  
Top  
26. 3-40-121.  
Draft.hood.heat.shield  
Control.door  
27. 1-10-08285.  
28. 3-44-08278.  
29. 3-40-820628.  
30. 3-40-82057.  
Control.heat.shield  
Baffle  
66  
2-00-4172  
LP.valve  
.
.
31  
32  
33  
34  
35  
36  
3-40-57356  
3-40-64347  
3-40-64739  
3-40-57271  
3-40-57753  
3-40-57753  
#56 orifice, LP front/NG center  
#47 orifice, NG front  
#39 orifice, NG rear  
#71 orifice, LP center  
#53 orifice, LP rear  
#53 orifice, LP rear  
Piezo.cable  
37. 3-40-08231.  
38. 3-40-08229.  
Pilot,.NG  
1ꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clarity.B-Vent.-.Exploded.View  
1ꢃ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clarity.Burner.Module.-.Exploded.View  
38  
49  
40  
37  
14  
13  
12  
52  
33  
32  
41  
31  
51  
50  
43  
44  
48  
42  
1ꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix.A  
step 3: Using a small flat-blade screwdriver, remove  
the.three.screws.that.hold.the.LP.knob.module.in.place..  
Remove.the.module.and.replace.it.with.the.Natural.Gas.  
module.from.the.kit..See.kit.instructions.  
step 4: Affix the conversion label to the valve so that any  
future.service.tech.etc....can.plainly.see.that.the.valve.was.  
converted.  
step 5: Mark.the.appropriate.fuel.box.on.the.unit.label.  
using.a.permanent.marker.  
step 6: Affix the Installer Fuel Label in place of the exist-  
ing.one.  
ConVeRTInG THe ClaRITY b-VenT fRoM  
one Gas To anoTHeR In THe fIelD  
noTe: THe ConVeRsIon sHall be CaR-  
RIeD oUT In aCCoRDanCe WITH THe Re-  
qUIReMenTs of THe PRoVInCIal oR loCal  
aUTHoRITIes HaVInG JURIsDICTIon anD In  
aCCoRDanCe WITH ReqUIReMenTs of THe  
CURRenTeDITIon ofTHe naTIonalfUelGas  
CoDe, ansI Z223.1 or the Can/CGa-b149 InsTal-  
laTIon CoDes.  
.Important: Perform a leak test upon completion  
of the fuel conversion.  
ConVeRsIon kIT CoMPonenTs  
*1 Pilot Orifice  
*2 Burner Orifices  
*.Regulator.Assembly  
*.Conversion.Instructions  
*.Installer.Fuel.Label  
*.Conversion.Label-Must be  
attached to valve upon com-  
pletion.  
NATURAL GAS  
PROPANE  
Steps For Completing The Fuel Conversion.  
Prior.to.installing.the.fuel.conversion,.remove.the.Glass.  
door.and.the.log.set,.to.gain.access.to.the.burner.module..  
Remove.the.burner.tubes.by.sliding.to.the.left.while.lift-  
ing.upward..Remove.the.burner.cover.plate.and.the.tube.  
box.top.  
step 1: Remove.pilot.hood.with.a.7/16”.wrench..Inside,.  
you will find and discard the Propane orifice. Install the  
new Natural Gas orifice from the kit. Tighten the pilot  
hood.and.assure.proper.alignment.of.the.directional.open-  
ings.  
step 2:.Using.a.1/2.in..deep-well.socket,.remove.the.  
three main burner orifices. Install the new orifices accord-  
ingly; Front = #47, Middle = #56, Rear = #39. Notice  
the.#56.that.you.removed.from.the.front.will.be.used.in.  
the.middle.for.Natural.Gas..Apply.a.thread.sealer.to.the.  
orifices prior to installing.  
CaUTIon: label all WIRes PRIoR To DIsConneC-  
TIon WHen seRVICInG ConTRols. WIRInG eRRoRs  
Can CaUse IMPRoPeR anD DanGeRoUs oPeRaTIon.  
VeRIfY PRoPeR oPeRaTIon afTeR seRVICInG.  
see WIRInG DIaGRaM on PaGe 13.  
1ꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix.B  
De-RaTInG foR HIGH alTITUDe  
For.U.S..installations,.the.Clarity.B-Vent.is.approved.  
for.elevations.up.to.2000.feet.using.the.factory-installed.  
burner.injectors..At.elevations.above.2000.feet,.U.S..codes.  
require.a.decrease.in.the.input.rating.by.changing.the.burner.  
injectors.to.a.smaller.size..The.chart.below.lists.by.part.  
numbers.the.appropriate.injectors.for.both.LP.and.natural.  
gas.at.various.altitudes.  
For.Canadian.installations,.the.Clarity.B-Vent.is.ap-  
proved.for.elevations.up.to.610.meters.(2000.feet)..For.  
installations.from.610-1370.meters.(2000-4500.ft.).the.  
orifice sizes (DMS) for natural and propane gas are as  
shown.in.the.chart.below.  
.For.high.altitude.installations.consult.the.local.gas.dis-  
tributor.or.the.authority.having.jurisdiction.for.proper.rating.  
methods.  
NOTE:.The.difference.in.altitude.derating.requirements.  
for.the.U.S..and.Canada.is.simply.a.result.of.differences.in.  
testing.standards.between.the.two.countries.  
If.the.installer.must.convert.the.unit.to.adjust.for.varying.  
altitudes,.an.information.sticker.like.the.one.below.must.be.  
filled out and affixed to the appliance at the time of conver-  
sion.  
naTURal Gas  
front  
Harman  
Center Harman  
Injector Part no.  
Rear  
Injector Part no.  
Harman  
nominal btu  
Input Rate  
40,000.  
38,400  
36,900  
35,400  
34,000.  
32,600  
31,300  
altitude  
Injector Part no.  
0-2000'.  
47.  
48.  
49.  
49.  
50.  
50.  
51.  
51.  
3-40-64347.  
56.  
56.  
56.  
57.  
57.  
57.  
58.  
58.  
3-40-57356.  
39.  
40.  
41.  
42.  
42.  
43.  
43.  
44.  
3-40-64739.  
2000-3000'.  
3000-4000'.  
4000-5000'.  
5000-6000'.  
6000-7000'.  
7000-8000'.  
8000-9000'.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
3-40-57356.  
3-40-57356.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
.
.
.
.
.
.
.
MALE.  
MALE.  
30,100  
PRoPane  
front  
Injector Part no.  
Harman  
Center Harman  
Injector Part no.  
Rear  
Injector Part no.  
Harman  
nominal btu  
Input Rate  
40,000.  
36,900  
36,900  
35,400.  
32,600.  
32,600.  
30,100.  
altitude  
0-2000'.  
56.  
56.  
56.  
57.  
57.  
57.  
58.  
58.  
3-40-57356.  
71.  
71.  
71.  
71.  
71.  
71.  
71.  
71.  
3-40-57271.  
53.  
54.  
54.  
54.  
55.  
55.  
56.  
56.  
3-40-57753.  
2000-3000'.  
3000-4000'.  
4000-5000'.  
5000-6000'.  
6000-7000'.  
7000-8000'.  
8000-9000'.  
3-40-57356.  
3-40-57356.  
MALE.  
MALE.  
MALE.  
3-40-57271.  
3-40-57271.  
3-40-57271.  
3-40-57271.  
3-40-57271.  
3-40-57271.  
3-40-57271.  
MALE.  
MALE.  
MALE.  
MALE.  
MALE.  
.
.
.
.
.
MALE.  
MALE.  
3-40-57356.  
3-40-57356.  
30,100  
●When ordering injectors that have no Harman  
Part number, specify Male or feMale and  
the appropriate 2- digit number.  
THe ConVeRsIon sHall be CaRRIeD oUT  
bY a ManUfaCTUReR's aUTHoRIZeD ReP-  
ResenTaTIVe In aCCoRDanCe WITH THe  
ReqUIReMenTs of THe ManUfaCTUReR,  
PRoVInCIal oR TeRRIToRIalaUTHoRITIes  
HaVInG JURIsDICTIon anD In aCCoRDanCe  
WITH THe ReqUIReMenTs ofTHe CURRenT  
eDITIon of Can/CGa-b141.1 oR Can/CGa-  
b141.2 InsTallaTIon CoDes.  
This.appliance.has.been.converted.for.use.at.an.altitude.of.__________ft.  
Orifice Sizes: Front ________ Center_________ Rear ________  
Input.(Btu/hr)............._________________  
Manifold.Pressure......__________________  
Fuel.Type............_______________________  
Converted.By...._________________________________  
Date.of.Conversion.._______________________________  
1ꢆ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clarity.B.Vent..  
Gas Heater Specifications  
Tested.to.ANSI.Z21.88-2002,.CSA.2.33-M02,.CAN/CGA.2.17-M91.  
.
naTURal Gas  
PRoPane  
40,000  
28,000  
56/71/53  
10.0/2.49  
5.9/1.47  
11.0/2.74  
30,800  
Input.Rating.(Btu/hr).(0-1375.m).  
40,000.  
27,000.  
47/56/39.  
3.5/0.87.  
1.7/0.42.  
5.0/1.25.  
30,500.  
65.2%.  
Min..Input.Rating.(Btu/hr)..(0-1375.m).  
Injector.Sizes.(DMS).(front/center/rear..(0-1375.m).  
Manifold.Pressure.(in.w.c./kPa)....  
Minimum.Manifold.Pressure.(in.w.c./kPa)....  
Minimum.Inlet.Pressure.(in.w.c./kPa)....  
Maximum.Output.(Btu/hr)..(0-1375.m)...  
AFUE (seasonal efficiency; minimum venting)  
Steady State Efficiency (max. input, blower on High)  
66.0%.  
79.7%...  
78.2%.  
MInIMUM CleaRanCes fRoM CoMbUsTIble ConsTRUCTIon  
Unit.to.left.sidewall.  
Unit.to.right.sidewall.  
Unit.corner.to.walls.  
Rear.of.unit.to.back.wall..  
(measured.from.rear.of.draft.hood.heat.shield)  
Unit.to.alcove.ceiling.  
9.in... (230.mm).  
9.in... (230.mm)  
4.in... (100.mm).  
3.in... (75.mm)..  
18.in... (460.mm).  
14.in... (355.mm)  
Maximum.alcove.depth.  
Electrical.Rating:.120.Volts,.60.Hz.,.Less.than.1..Amp  
.....Stove.Weight:..234.lbs.  
1ꢇ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HaRMan GolD WaRRanTY  
6 YeaR TRansfeRable lIMITeD  
WaRRanTY (Residential)  
1 YeaR lIMITeD WaRRanTY (Commercial)  
Harman.Stove.Company.warrants.its.products.to.be.free.from.defects.in.material.or.workmanship,.in.normal.use.and.ser-  
vice,.for.a.period.of.6.years.from.the.date.of.sales.invoice.and.for.mechanical.and.electrical.failures,.in.normal.use.and.service,.  
for.a.period.of.3.years.from.the.date.of.sales.invoice.  
If.defective.in.material.or.workmanship,.during.the.warranty.period,.Harman.Stove.Company.will,.at.its.option,.repair.or.  
replace.the.product.as.described.below.  
The.warranty.above.constitutes.the.entire.warranty.with.respect.to.Harman.Stove.Company.products...HARMAN.STOVE.  
COMPANY..MAKES..NO..OTHER..WARRANTY,..EXPRESSED..OR..IMPLIED,..INCLUDING..“ANY”..WARRANTY.  
OF.MERCHANTABILITY,..OR..WARRANTY..OF..FITNESS..FOR..A..PARTICULAR..PURPOSE...No.employee,.agent,.  
dealer,.or.other.person.is.authorized.to.give.any.warranty.on.behalf.of.Harman.Stove.Company...This.warranty.does.not.apply.  
if.the.product.has.been.altered.in.any.way.after.leaving.the.factory...Harman.Stove.Company.and.its.agents.assume.no.liability.  
for.“resultant.damages.of.any.kind”.arising.from.the.use.of.its.products...In.addition,.the.manufacturer.and.its.warranty.admin-  
istrator.shall.be.held.free.and.harmless.from.liability.from.damage.to.property.related.to.the.operation,.proper.or.improper,.of.  
the.equipment.  
THERE..ARE..NO..WARRANTIES..WHICH..EXTEND..BEYOND..THE..DESCRIPTION..ON..THE..FACE..HERE-  
OF.  
THESE..WARRANTIES..APPLY.only.if.the.device.is.installed.and.operated.as.recommended.in.the.user’s.manual.  
THESE..WARRANTIES.WILL..NOT..APPLY.if.abuse,.accident,.improper.installation,.negligence,.or.use.beyond.rated.  
capacity.causes.damage.  
HOW..TO.MAKE.A.CLAIM.-.Any.claim.under.this.warranty.should.be.made.to.the.dealer.from.whom.this.appliance.  
was.purchased...Then.contact.is.made.with.manufacturer,.giving.the.model.and.serial.numbers,.the.date.of.purchase,.your.  
dealer’s.name.and.address,.plus.a.simple.explanation.of.the.nature.of.the.defect...Extra.costs.such.as.mileage.and.overtime.are.  
not.covered...Nuisance.calls.are.not.covered.by.these.warranties.  
THIS...WARRANTY...IS...LIMITED...TO...DEFECTIVE...PARTS.-.REPAIR...AND/OR...REPLACEMENT...AT...HAR-  
MAN...STOVE..COMPANY’S...OPTION...AND...EXCLUDES...ANY..INCIDENTAL...AND...CONSEQUENTIAL...DAM-  
AGES...CONNECTED..THEREWITH.  
WARRANTY EXCLUSIONS: Failure due, but not limited to, fire, lightning, acts of God, power failures and/or surges,  
rust, corrosion and venting problems are not covered. Damage and/or repairs including but not limited to; remote controls,  
filters, fuses, knobs, glass, ceramic brick panels, ceramic fiber afterburners, door packing, tile, ceramic log sets, paint, batteries  
or.battery.back-up.and.related.duct.work.are.not.covered..Also.excluded.from.this.warranty.are.consumable.or.normal.wear.  
items including but not limited to; flame guides, grates, coal bars, afterburner hoods, fire brick, gaskets. Additional exclusions  
for.corn.stoves.are.burnpot.housing.weldment,.burnpot.grate.weldment.(pellet.or.corn),.burnpot.front.plate.(pellet.or.corn),.  
burnpot.front.plate.lock,.corn.auger.extension,.ceramic.insert,.and.ceramic.insert.plate..Additional.or.unusual.utility.bills.incurred.  
due.to.any.malfunction.or.defect.in.equipment.and.the.labor.cost.of.gaining.access.to.or.removal.of.a.unit.that.requires.special.  
tools.or.equipment.are.not.covered...Maintenance.needed.to.keep.the.stove.in.“good.operating.condition”.is.not.covered...This.  
includes,.but.is.not.limited.to,.cleaning,.adjustment.of.customer.controls.and.customer.education...Labor,.materials,.expenses.  
and/or.equipment.needed.to.comply.with.law.and/or.regulations.set.forth.by.any.governmental.agencies.are.not.covered..  
This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state.  
In.the.event.of.change.in.ownership,.the.remaining.portion.of.this.warranty.may.be.transferred.to.the.new.owner.by.send-  
ing.the.new.owner.information.and.a.transfer.fee.of.$25.00.US.to.the.Harman.Stove.Company.  
PLEASE..READ..THE..LITERATURE..BY..THE..MANUFACTURER..FOR..THE..VARIOUS..ACCESSORY..DEVICES..  
THE.MANUFACTURER..WARRANTS..THESE..ACCESSORY..DEVICES,..NOT..HARMAN..STOVE..COMPANY..OR.  
THEIR.WARRANTY..ADMINISTRATOR....FURTHERMORE,..THESE..ACCESSORY..DEVICES..MUST..BE..INSTALLED.  
AND..USED.ACCORDING..TO..THE..RECOMMENDATIONS..OF..THE..MANUFACTURER.  
REMEDIES.-.The.remedies.set.forth.herein.are.exclusive.and.the.liability.of.seller.with.respect.to.any.contract.or.sale.  
or.anything.done.in.connection.therewith,.whether.in.Contract,.in.tort,.under.any.warranty,.or.otherwise,.shall.not,.except.as.  
herein.expressly.provided,.exceed.the.price.of.the.equipment.or.part.of.which.such.liability.is.based.  
CLARIFY.-.The.above.represents.the.complete.warranty,.which.is.given.in.connection.with.stoves,.manufactured.by.Harman.  
Stove.Company...No.other.commitments,.verbal.or.otherwise,.shall.apply.except.by.a.written.addendum.to.this.warranty.  
ꢀ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graham Field Blood Pressure Monitor 707A User Manual
Haier Water Dispenser HLM 801B User Manual
Hamilton Beach Iron 840068700 User Manual
Harbor Freight Tools Welder 6098 User Manual
Havis Shields Automobile Accessories C TM F250 1 User Manual
Honeywell Home Security System 128BPTSIA User Manual
Honeywell Ventilation Hood W8150 User Manual
Hotpoint Refrigerator 39 6240 User Manual
HP Hewlett Packard Camera Accessories PhotoSmart User Manual
Ice O Matic Ice Maker GEM 0956 User Manual