		 1 HP cast Iron   
					sewage PumP   
					66351   
					set uP, oPeratIng, and maIntenance   
					InstructIons   
					Visit our website at: http://www.harborfreight.com   
					read this material before using this product.   
					Failure to do so can result in serious injury.   
					saVe tHIs manual.   
					© 
					® 
					Copyright 2008 by Harbor Freight Tools . All rights reserved. No portion of this manual or any artwork   
					contained herein may be reproduced in any shape or form without the express written consent of   
					Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing   
					improvements, actual product may differ slightly from the product described herein. Tools required for   
					assembly and service may not be included.   
					For technical questions or replacement parts, please call 1-800-444-3353.   
					Revised Manual 09i   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ductor in the cord is the grounding   
					wire. Do not connect the green or   
					green and yellow wire to a live termi-   
					nal.   
					d. do not operate this sewage   
					Pump if either the Power cord (1),   
					Power Plug (29), Housing (10), or   
					Base (27), appear cracked or dam-   
					aged in any way.   
					e. warnIng! do not repair a dam-   
					aged power cord. always replace   
					the cord before further use of this   
					sewage Pump.   
					f. do not place this sewage Pump   
					in water with bare hands. always   
					wear heavy-duty, insulated rubber   
					gloves.   
					Your unit has a plug as illustrated   
					above. The outlet used should look   
					like the outlet illustrated above. do   
					not remove the grounding prong   
					from the plug. If the plug will not   
					fit the outlet, have a proper outlet   
					installed by a qualified electrician.   
					g. do not attach the power plug to   
					electrical outlet until the sewage   
					Pump is placed where it will re-   
					main during operation.   
					h. always unplug the sewage Pump   
					before touching, moving, inspect-   
					ing, or servicing.   
					5. WARNING: Handling the cord on   
					this product will expose you to lead,   
					a chemical known to the State of   
					California to cause cancer, and birth   
					defects or other reproductive harm.   
					Wash hands after handling. (Califor-   
					nia Health & Safety Code § 25249.5,   
					et seq.)   
					2. Keep children away when assem-   
					bling, setting up, inspecting and/or   
					servicing this sewage Pump.   
					3.   
					Wear ANSI-approved safety   
					goggles, heavy-duty insu-   
					lated rubber work gloves   
					and rubber boots while working with   
					or around this Sewage Pump.   
					General and Specific Safety   
					1. warnIng: to prevent serious per-   
					sonal injury and/or death to your-   
					self and/or others:   
					4. Do not Overreach - Keep proper foot-   
					ing and balance at all times.   
					5. Stay Alert - Watch what you are do-   
					ing. Use common sense.   
					a. do not use this sewage Pump to   
					pump any flammable, or explosive   
					fluids, such as gasoline, fuel oil,   
					kerosene, etc.   
					b. DO NOT use in flammable, and/or   
					explosive atmosphere.   
					c. use this sewage Pump only with   
					liquids compatible with pump   
					component materials.   
					SKU 66351   
					For technical questions, please call 1-800-444-3353.   
					Page 3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				product, but must be supplied by the   
					operator.   
					drip loop   
					outlet   
					saVe tHese   
					InstructIons.   
					deVIce   
					sPecIFIcatIons   
					cord   
					Electrical Information 120 V, 60 Hz, 10.5 AMPS   
					6. Use Drip-Loop to prevent water from   
					accidentally entering the electrical   
					power outlet. Use only with a GFCI   
					outlet. see second paragraph in   
					“Power cord safety” section of   
					this manual.   
					Gallons Per Minute   
					Pump Motor   
					110   
					1 HP, 3450 RPM   
					unPacKIng   
					When unpacking, check to make sure   
					that the item is intact and undamaged. If   
					any parts are missing or broken, please   
					call Harbor Freight Tools at the number   
					shown on the cover of this manual as soon   
					as possible.   
					use and care   
					1. When servicing use only identical   
					replacement parts.   
					2. Do not use this Sewage Pump for   
					any job except that for which it is   
					intended.   
					set uP InstructIons   
					3. disconnect the sewage Pump from   
					the power supply when not in use,   
					or before inspection and/or ser-   
					vice/storage.   
					read the entIre ImPortant   
					saFety InstructIons   
					section at the beginning of this   
					manual including all text under   
					subheadings therein before set   
					up or use of this product.   
					4. Store Idle Sewage Pump Indoors   
					when not in use out of reach of chil-   
					dren.   
					to   
					PreVent   
					serIous   
					5. Maintain labels and nameplates on   
					the appliance. These carry important   
					safety information. If unreadable or   
					missing, contact Harbor Freight Tools   
					for a replacement.   
					Injury From accIdental   
					oPeratIon:   
					unplug the sewage Pump   
					from its electrical outlet   
					before assembling,   
					inspecting, making any   
					adjustments, or servicing.   
					6. The warnings, precautions, and in-   
					structions discussed in this instruction   
					manual cannot cover all possible con-   
					ditions and situations that may occur.   
					It must be understood by the operator   
					that common sense and caution are   
					factors which cannot be built into this   
					note: For additional information regarding   
					the parts listed in the following pages,   
					SKU 66351   
					For technical questions, please call 1-800-444-3353.   
					Page 4   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				refer to the Assembly Diagram near   
					the end of this manual.   
					oPeratIng InstructIons   
					read the entIre ImPortant   
					saFety InFormatIon section   
					at the beginning of this manual   
					including all text under   
					subheadings therein before set   
					up or use of this product.   
					assemBly   
					1. Thread a discharge hose, or pipe   
					(not supplied) to the orifice on side of   
					Base (27).   
					1. Before operating the Sewage Pump,   
					put on ANSI-approved safety gog-   
					gles and other safety gear including   
					heavy-duty, insulated rubber gloves.   
					Safety goggles and other safety gear   
					are sold separately.   
					2. If you use a check-valve (not sup-   
					plied), mount the check valve hori-   
					zonally or at 45°. The valve pivot   
					should be on top. NOTE: If the   
					check valve should be mounted in a   
					vertical position, solid waste will tend   
					to lodge on top of the valve flapper   
					preventing it from opening.   
					2. Install the Sewage Pump firmly on it’s   
					Legs and supported by rigid hose, or   
					pipe discharge fixtures to eliminate   
					twisting and damage from motor   
					torque during operation.   
					3. If using a check-valve, drill a 1/16”   
					hole in the discharge hose, or pipe 1”   
					to 2” above the Base (27). The hole   
					will prevent an air lock in the Mo-   
					3. After installation, allow the Sew-   
					age Pump to flood with water before   
					plugging Power Cord (1) into outlet.   
					This will help prevent over heating   
					from running the Motor (18) with no   
					water resistance moving through the   
					Sewage Pump. Once this Sewage   
					Pump is plugged into a 120 Volt GFCI   
					outlet, the Motor (18) will start auto-   
					matically.   
					tor (18) both at start up and/or if the   
					Sewage Pump should lose its prime.   
					4. After the check-valve, a (full-port)   
					gate-valve (not supplied), which will   
					pass 2” solid waste should be in-   
					stalled in the system. The gate-valve   
					allows removal of the Sewage Pump   
					for cleaning and service.   
					note: If you do not feel qualified to   
					completely (and safely) install this   
					sewage Pump, it is recommended   
					that you have it installed by a   
					qualified plumber, or service tech-   
					nician.   
					4. This Sewage Pump is designed to   
					transfer waste water in cycles.   
					Rev 09i   
					SKU 66351   
					For technical questions, please call 1-800-444-3353.   
					Page 5   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				warnIng: this sewage Pump contains   
					dielectric motor oil for both lubri-   
					cation and heat transfer. It may be   
					under pressure because of heat   
					collection. let the sewage Pump   
					cool for at least 2 hours before   
					inspecting, or servicing. this oil   
					may be dangerous to the environ-   
					ment. always dispose of used oil   
					in compliance with all local, state   
					and Federal rules and regulations.   
					maIntenance and   
					serVIcIng   
					Procedures not specifically   
					explained in this manual   
					must be performed only by a   
					qualified technician.   
					to PreVent   
					serIous Injury   
					From accIdental   
					oPeratIon or electrIc   
					sHocK:   
					unclogging the Impeller (24).   
					unplug the sewage Pump   
					from its electrical outlet   
					before performing any   
					accessory change, inspection,   
					maintenance, and/or cleaning   
					procedures.   
					1. Unplug the Sewage Pump, put on   
					heavy-duty insulated rubber gloves   
					and ANSI-approved safety goggles.   
					2. Remove the discharge hose, or pipe.   
					3. Lift Sewage Pump out of water using   
					the Handle (5).   
					to PreVent serIous   
					Injury From tool   
					FaIlure:   
					do not use damaged   
					equipment. If abnormal noise   
					or vibration occurs, have the   
					problem corrected before   
					further use.   
					4. To unclog the Impeller (24), remove   
					5 Screws (28) on the Sewage Pump   
					bottom and remove Base (27).   
					5. Flush the Impeller (24) with clean,   
					lukewarm water.   
					6. Reinstall the Impeller (24) and re-   
					place the Base (27) using the 5   
					Screws (28).   
					cleaning, maintenance, and   
					lubrication   
					7. Using the Handle (5), replace the   
					Sewage Pump into water in original   
					position.   
					1. BeFore use and PerIodIcally   
					tHereaFter, inspect the gen-   
					eral condition of the Sewage Pump.   
					Check for loose screws, misalignment   
					or binding of moving parts, cracked or   
					broken parts, damaged electrical wir-   
					ing, and any other condition that may   
					affect its safe operation.   
					8. Re-thread the discharge pipe, or   
					hose.   
					9. Plug the Sewage Pump back into the   
					120 Volt, GFCI power outlet.   
					2.   
					warnIng! If the supply cord of   
					this appliance is damaged, it must   
					be replaced only by a qualified   
					service technician.   
					10. The Sewage Pump will start auto-   
					matically.   
					SKU 66351   
					For technical questions, please call 1-800-444-3353.   
					Page 6   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				troubleshooting   
					Problem   
					Possible causes   
					likely solutions   
					1. Check power at outlet.   
					Sewage Pump will not 1. No power at outlet.   
					start.   
					2. Circuit breaker tripped.   
					2. Check circuit breaker for outlet.   
					3. Check that cord is plugged in.   
					4. Check water level.   
					3. Cord not connected.   
					4. Water level too low.   
					Low flow from   
					1. Possible excess solid debris lodged 1. Check and clean debris from   
					discharge outlets.   
					Sewage Pump starts   
					and stops too often.   
					in Impeller.   
					1. Possible back flow from discharge   
					pipe and/or hoses.   
					Impeller per instructions on Page 6.   
					1. Install a check-valve.   
					2. Check-valve either not installed, or if 2. Remove and examine check-valve   
					installed, it is leaking.   
					for proper installation and operation.   
					Replace if necessary.   
					Sewage Pump   
					operates but delivers   
					little or no water.   
					1. Low line voltage.   
					1. If voltage is under recommended   
					minimum, check wiring size from the   
					main switch on property. If not OK,   
					contact local power company.   
					2. Debris caught in Impeller or   
					discharge hoses or pipes.   
					2. Remove and check Impeller and   
					discharge hoses or pipes. Clean if   
					needed.   
					3. Check-valve stuck closed or   
					installed backwards.   
					3. Remove and examine check-valve   
					and reinstall correctly or replace.   
					Follow all safety precautions whenever diagnosing or servicing the   
					appliance. disconnect power supply before service.   
					Please read tHe FollowIng careFully   
					THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY   
					DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR   
					DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT   
					HE OR SHE IS qUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS   
					qUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR   
					DISTRIBUTOR ExPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE   
					UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER   
					ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL   
					PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION   
					OF REPLACEMENT PARTS THERETO.   
					REV 09i   
					SKU 66351   
					For technical questions, please call 1-800-444-3353.   
					Page 7   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Parts lIst   
					Parts lIst   
					Part   
					description   
					Q’ty   
					1 
					2 
					1 
					2 
					1 
					1 
					1 
					1 
					1 
					1 
					2 
					1 
					4 
					1 
					Part   
					description   
					Q’ty   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					Power Cord   
					17 Motor Shaft   
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					6 
					1 
					1 
					5 
					1 
					Screw 3/16 - 24 x 1/4   
					Cord Cover (Protector)   
					Screw 1/4 - 20 x 1/4   
					Handle   
					Washer 3/16   
					Strain Relief   
					18 Motor   
					19 Washer 6202zz - 12.7   
					20 Mechanic Seal Typ 21   
					21 O-Ring   
					22 Motor Seat   
					23 V-Seal   
					Screw 3/16 24 x 308   
					1/4” NPT Oil Plug   
					24 Impeller   
					25 Flat Screw 3/16 - 24 x 5/8   
					26 Packing Gasket   
					27 Base   
					28 Screw 1/4 - 20 x 3/4   
					29 Power Plug   
					10 Pump Motor Housing   
					11 Washer 3/16 x 1/4   
					12 Capacitor 40uf/350 V Vac   
					13 Screw M4 x 130   
					14 Rear Cover   
					15 Washer   
					2 
					16 Washer 608zz   
					1 
					assemBly dIagram   
					SKU 66351   
					For technical questions, please call 1-800-444-3353.   
					Page 8   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				lImIted 90 day warranty   
					Harbor Freight Tools Co. makes every effort to assure that its products meet high   
					quality and durability standards, and warrants to the original purchaser that this prod-   
					uct is free from defects in materials and workmanship for the period of 90 days from   
					the date of purchase. This warranty does not apply to damage due directly or indirectly,   
					to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities,   
					criminal activity, improper installation, normal wear and tear, or to lack of maintenance.   
					We shall in no event be liable for death, injuries to persons or property, or for incidental,   
					contingent, special or consequential damages arising from the use of our product. Some   
					states do not allow the exclusion or limitation of incidental or consequential damages, so   
					the above limitation of exclusion may not apply to you. THIS WARRANTY IS ExPRESS-   
					LY IN LIEU OF ALL OTHER WARRANTIES, ExPRESS OR IMPLIED, INCLUDING THE   
					WARRANTIES OF MERCHANTABILITY AND FITNESS.   
					To take advantage of this warranty, the product or part must be returned to us with   
					transportation charges prepaid. Proof of purchase date and an explanation of the com-   
					plaint must accompany the merchandise. If our inspection verifies the defect, we will ei-   
					ther repair or replace the product at our election or we may elect to refund the purchase   
					price if we cannot readily and quickly provide you with a replacement. We will return re-   
					paired products at our expense, but if we determine there is no defect, or that the defect   
					resulted from causes not within the scope of our warranty, then you must bear the cost   
					of returning the product.   
					This warranty gives you specific legal rights and you may also have other rights   
					which vary from state to state.   
					3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353   
					record Product’s serial number Here:   
					note: If product has no serial number, record month and year of purchase instead.   
					note: Some parts are listed and shown for illustration purposes only, and are not avail-   
					able individually as replacement parts.   
					SKU 66351   
					For technical questions, please call 1-800-444-3353.   
					Page 9   