Owners &
U32 Gas Insert
Installation Manual
MODELS: U32-NG5 Natural Gas U32-LP5 Propane
WARNING:
FOR YOUR SAFETY
Improper installation, adjustment, alteration, service or What to do if you smell gas:
maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information consult
an authorized installer, service agency or the gas supplier.
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
918-677b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
03/05/08
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
OPERATING INSTRUCTIONS
SAFETY LABEL
Operating Instructions ................................................29
Lighting Procedure ......................................................29
Shutdown Procedure...................................................29
First Fire ......................................................................29
Automatic Convection Fan Operation ........................29
Normal Operating Sounds Of Gas Appliances............29
Copy Of Lighting Instruction Plate...............................30
Serial No. Decal ............................................................4
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)............................5
INSTALLATION
MAINTENANCE
Important Message ......................................................6
For Your Safety..............................................................6
Specifications ................................................................6
Gas Pressure Testing ....................................................6
Installation Into A Solid Fuel Burning
Maintenance Instructions ...........................................30
General Vent Maintenance..........................................31
Log Replacement ........................................................31
Glass Gasket...............................................................31
Gold-plated Trim..........................................................31
Door Glass .................................................................31
Fan Maintenance.........................................................32
Valve Replacement......................................................33
Fireplace Or Factory Built Fireplace..............................6
Before You Start ............................................................6
Installation Checklist......................................................7
Manufactured Mobile Home Additional Requirements ..7
Materials Required ........................................................7
Minimum Fireplace Dimensions ....................................7
Clearances To Combustibles.........................................7
Gas Connection ............................................................8
Venting ..........................................................................8
Flue Liner Installation ....................................................8
Gas Pipe Pressure Testing............................................9
Gas Insert Aeration System...........................................9
Optional Brick Panel......................................................9
Log Set Installation......................................................10
Regency Faceplate & Trim Installation........................14
Standard Flush Door ...................................................15
Optional Flush Trim .....................................................15
Optional Double Screen Doors....................................15
Flush Louvers..............................................................15
Bay Louvers ................................................................16
Optional Bay Door.......................................................16
Optional Bay Trim........................................................16
Conversion Kit #514-969 from NG to LP ...................17
Full Screen Doors........................................................20
Hampton® Cast Faceplate Installation.........................22
Hampton® Cast Grill Installation ..................................23
The Kensington® Front Installation ..............................24
The Kensington® 2-panel Door Installation..................25
PARTS LIST
Main Assembly ............................................................34
Burner Assembly & Log Set ........................................35
Bay & Flush Front Assembly .......................................36
Faceplate Assembly ....................................................37
Hampton® Cast - Faceplate Assembly.........................38
WARRANTY
The Warranty: Limited Lifetime...................................39
The Kensington® 3-panel Door Installation .................26
Optional Wall Thermostat ...........................................26
Optional Remote Control ............................................26
Final Check .................................................................26
Wiring Diagrams..........................................................27
U32-5 FPI Direct Vent Gas Insert
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY LABEL
This is a copy of the labels that accompany each U32-5 Gas Insert. We NOTE: FPI units are constantly being improved. Check the label
have printed a copy of the contents here for your review. The safety label on the unit and if there is a difference, the label on the unit is the
is located on a plate inside the base of the unit visible when the bottom correct one.
louver is opened.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
4
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
U32-5 FPI Direct Vent Gas Insert
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
General Safety Information
GAS PRESSURE
TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than
IMPORTANT MESSAGE
SAVE THESE
1) The appliance installation must conform
with local codes or in the absence of local
codes, with CAN/CGAB149 (in Canada) or
the National Fuel Gas CodeANSI Z223.1 in
theU.S.A.Thisapplianceshouldbeinstalled
by a qualified gas fitter technician only.
INSTRUCTIONS
The FPI Gas Insert must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual first.
Consultthebuildingauthorityhavingjurisdiction
todeterminetheneedforapermitpriortostarting
the installation.
2) Installation and repair should be done
by a qualified service person.
1/2 psig. (3.45 kPa).
3) The appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting,beddingmaterial,animalhair,etc.
It is imperative that control compartments,
burners and circulating air passageways of
the appliance be kept clean.
NOTE: Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/or
property damage. Failure to follow these
instructions may also void your fire insurance
and/or warranty.
INSTALLATION INTO A
SOLID FUEL BURNING
FIREPLACE OR
FACTORY BUILT
FIREPLACE
4) See general construction and assembly
instructions. This appliance may only be
installed in a vented, noncombustible
fireplace.
FOR YOUR SAFETY
The U32-5 Gas Inserts have been tested and
approvedtobeventedintoanymasonryfireplace
or approved solid fuel burning factory built
fireplace that will allow the insert to physically
fit into the firebox. Refer to "Minimum Fireplace
Dimensions" section for minimum fireplace
clearances.
Thisappliancerequiresairforpropercombustion.
Always provide adequate combustion and
ventilation air. Follow instructions and
information in CAN/CGA B149 (in Canada) or
theNationalFuelGasCodeANSIZ223.1(inthe
USA), regarding requirements for combustion
and ventilation air.
5) This appliance is Listed for bedroom
installationswhenusedwithaListedMillivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
If the factory built fireplace* height is too low for
your Insert, you may remove the smoke baffle
plate, damper, refractory (firebricks), glass
doors, screen rails, screen mesh and log grates
from the factory built fireplace as long as these
items are saved and are reinstalled in the event
that the Insert is removed.
6) Always connect this insert to a vent system
venting to the outside of the building
envelope. Never vent to another room or
inside a building. Make sure that the vent
is properly sized and is of adequate height
to provide the proper draft.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
Smoke shelves, shields and baffles may be
removed if attached by mechanical fasteners.
If any part is removed it must not weaken the
structural integrity of the factory built fireplace.
7) Inspect the venting system annually for
Gas Input Capacity:
blockage and any signs of deterioration.
Natural Gas 30,000 Btu/h
8) Any glass removed for servicing must be
Propane
30,000 Btu/h
replaced prior to operating the appliance.
NOTE: Any alterations made to the listed solid
fuel burning factory built fireplace may void the
listing of the fireplace.
Min. Input
Natural Gas 15,300 Btu/h
Propane 15,000 Btu/h
9) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
*Check with your local inspector before
commencing with this installation.
10) Due to high temperatures, the appliance
should be located out of high traffic areas
and away from furniture and draperies.
Children and adults should be alerted to
the hazards of high surface temperatures,
especially the fireplace glass and gold
trims, and should stay away to avoid burns
or clothing ignition. Young children should
be carefully supervised when they are in
the same room as the appliance. Clothing
or other flammable material should not be
placed on or near the appliance.
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to
4,500' (0-1370m).
Installer must mechanically attach the supplied
label to the inside of the firebox of the fireplace
into which the gas fireplace insert is installed.
Electrical: 120V A.C. system.
"WARNING:Thisfireplacehasbeenconverted
for use with a gas fireplace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the fireplace re-approved by the authority
having jurisdiction."
Circulation Fan: Variable speed, 110 CFM.
Log Set: Ceramic fibre, 7 per set.
Vent System: 3" co-linear aluminum flex.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
The efficiency rating of the appliance is a
product thermal efficiency rating determined
under continuous operating conditions and
was determined independent of any installed required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
system.
6
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
INSTALLATION
CHECKLIST
Before installing vent system ensure that the
damper plate is open and secure to prevent the
damper plate from falling down and crushing
the liner.
MANUFACTURED
MOBILE HOME
ADDITIONAL
CLEARANCES TO
COMBUSTIBLES
Minimum Clearances to Combustibles
REQUIREMENTS
From Unit
Sides
A
B
C
10" / 255 mm
47.5" / 1205 mm
see Dia. 2 & 3
1) Ensure that structural members are not cut
Ceiling
Mantel
or weakened during installation.
The FPI Gas Insert is installed as listed.
1) Checkallclearancestocombustibles,(Refer
tosections"MinimumFireplaceDimensions
and Clearances to Combustibles)
2) Ensure proper grounding using the #8
Max. Mantle Depth
G
12" / 305 mm
(see Dia. 2)
ground lug provided.
3) Appliance must be anchored to the floor
2) Make the gas connection. (Refer to section
Min. Alcove Width
Max. Alcove Depth
K
L
48" / 1220 mm
36" / 915 mm
with the supplied anchoring methods.
"Gas Connection")
3) Install the 3" flue liner to the sliding
connector plate. (Refer to section "Flue
Liner Installation.")
MATERIALS REQUIRED
Noelectricalpowersupplyisrequiredforthegas
control to operate. A120 VoltAC power cord is
hooked up to the fan. Plug the 3 wire cord into
a suitable receptacle. Do not cut the ground
terminaloffunderanycircumstances. When
connectedwith120volts,theappliancemustbe
electrically grounded in accordance with local
codes,currentversionofCSAC22.1(inCanada)
orintheabsenceoflocalcodes,withtheNational
Electrical Code ANSI/NFPA 70-1987.
4) Slide the unit half way into the fireplace.
5) Pull the vent connector plate through the
taperedbracketsandfastentothefrontplate.
Refer to section "Flue Liner Installation.")
6) Slide the unit fully into the fireplace.
7) Test gas pressure (Refer to section "Gas
Pipe Pressure Testing"). Check aeration
system(Refertosection"GasInsertAeration
System").
MINIMUM FIREPLACE
DIMENSIONS
Theminimumfireplaceclearances&dimensions
for the FPI gas insert are shown in the following
diagrams:
8) Installstandardandoptionalfeatures. Refer
to the following sections:
Diagram 1
a. Brick Panel
b. Lot Set
A
c. Faceplate & Trim
d. Standard Flush Door
e. Flush Trim
f. Double Screen Door
g. Flush Louvers
h. Bay Louvers
i. Bay Door
j. Bay Trim
k. Full Screen Doors
l. Hampton Cast Faceplate
m. Hampton Cast Grills
n. The Kensington Front
o. Wall Thermostat
p. Remote Control
Combustible Mantel Clearances
with Bay & Flush Louvers in
Masonry and Factory Built
Fireplace Installation
B
C
D
E
9) Finalcheck:Beforeleavingthisunitwiththe
customer, the installer must ensure that the
appliance is firing correctly. This includes:
Max Lentil
Bar Depth
A
Width
(rear)
D
Width
(front)
E
Height
B
Depth
C
Regency
Countour
Faceplate
9"
22"
14"
22-1/2"
26-1/2"
a) Clocking the appliance to ensure the
correct firing rate.
Regency
Molded
10"
22"
15"
22-1/2"
29"
Faceplate
b) Adjusting the primary air, if required, to
ensure that the flame does not carbon.
See "Gas Insert Aeration System"
section.
Diagram 2
Palace
Front
10"
9"
22"
22"
15"
14"
22-1/2"
22-1/2"
29"
Hampton
Cast
26-1/2"
Faceplate
c) Ensuring that the appliance is venting
Full
9"
22"
14"
22-1/2"
26-1/2"
correctly.
Screen
Doors
U32-5 FPI Direct Vent Gas Insert
7
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
The Air Intake pipe must be attached to the
inlet air collar of the termination cap.
VENTING
THE APPLIANCE MUST NOT BE
CONNECTED TO A
CHIMNEY FLUE SERVING A
SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex running
the full length of the chimney. The flue length
must be a minimum length of 8 ' (2.44m) and
a maximum of 35' (10.7m). See chart below for
minimumdistancesfromroof.Periodicallycheck
that the vent is unrestricted.
FLUE LINER
INSTALLATION
Masonry chimneys may take various contours
which the flexible liner will accommodate.
However,keeptheflexiblelinerasstraightas
possible, avoid unnecessary bending.
1) Cut the flex liner as required.
2) Mark the end of one liner to indicate
Inlet.
TheAir Intake pipe must be attached to the inlet
air collar of the termination cap.
3) Connect the other end of the above liner to
theinletsideoftheterminationadaptor,seal
connection with high temperature silicone.
Secure with gear clamp.
Part #
948-305
946-529
Description
Diagram 3
3" Flex - 35 ft.
Note: A noncombustible mantel may be
installed at a lower height if the
framing is made of metal studs
covered with a noncombustible
board.
Co-linear DV Vertical
Termination Cap
4) Connect the 2nd liner to the exhaust side
of the adaptor, seal connection with high
temperature silicone. Secure with gear
clamp.
GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work
with gas piping may make the
necessary gas connections
to this appliance.
1) If the appliance is to be installed into an
existing chimney system, thoroughly clean
the masonry or factory built fireplace.
2) Theapplianceisprovidedwithanopeningon
thelefthandsideofthecontrolcompartment.
A3/8"NPTgassupplypipemustbebrought
near this inlet hole.
3) Locate the center point where the vent
will pass through the chimney above the
appliance. Move the appliance into the
exact location where it is to be installed.
Ensure that the Insert is level.
Alternate Approved Caps
5) Install flashing.
980
Vertical Termination Cap
High Wind Cap
6) Insert both liners into chimney, passing
991
923GK
through the damper opening.
3" Co-linear Adaptor with flashing
7) Install termination cap.
In areas of consistently high winds, we
recommend using the Simpson Dura-Vent
System (923GK adapter and 991 high-wind
cap).
8) Connect the marked end of the liner to
the inlet collar of the vent connector plate
marked with an "I", seal connection with
high temperature silicone. Secure with gear
clamp.
8
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
1) Make sure the valve is in the "OFF"
OPTIONAL
position.
BRICK PANEL
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8"
wide flat screwdriver.
1) Unwrap the brick pattern panels from the
protective wrapping.
3) Attach manometer to "IN" and/or "OUT"
2) Remove the glass front if it is already
installed, see "Standard Flush Door"
section.
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position.
3) Put the rear brick panel flat against the back
of the unit.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specified on the safety
label.
6) When finished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" flat
screwdriver.Note:Screwshouldbesnug,
but do not over tighten.
Be careful not to damage thermal insula-
tion when sliding on vent connector plate.
This could cause blockage.
9) Connect the 2nd liner to the exhaust collar
marked with an "E", seal connection with
high temperature silicone. Secure with gear
clamp.
4) Beforeinstallingthesidebrickpanels,loosen
the screws for the brick tabs enough so that
you can slide the brick tabs on to the screws
easily but that the tabs are secure. For the
location of the side brick tab screws see
diagram 1.
GAS INSERT
AERATION SYSTEM
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
throughthebottomlouveropening.Opentheair
shutter for a blue flame or close for a yellower
flame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.
NOTES:
Minimum Air Shutter Opening:
3/16"
1/4"
Natural Gas
Propane
1) Final gas connection should be made after
unit is in place to avoid damage to line when
pushing the unit into position.
2) Mill-pac may be used instead of high
temperature silicone and screws may be
used instead of gear clamps at connections
of liner to inlet and vent collars.
Diagram 1
GAS PIPE
5) Remove the brick tabs and slide the side
brick panels into position. See diagram 1.
Install the brick tabs. See diagram 2.
PRESSURE TESTING
Aeration Adjustment Wire
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa). Disconnectpipingfromvalveatpressures
over 1/2 psig.
PULL= Open
PUSH = Close
CAUTION:Carbonwillbeproducedifairshutter
is closed too much.
Note:anydamageduetocarboningresulting
fromimproperlysettingtheaerationcontrols
is NOT covered under warranty.
Themanifoldpressureiscontrolledbyaregulator
builtintothegascontrol, andshouldbechecked
at the pressure test point.
Note: Aeration Adjustment should only
be performed by an authorized FPI
Installer at the time of installation or
service.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
Diagram 2
U32-5 FPI Direct Vent Gas Insert
9
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
LOG SET INSTALLATION
Readtheinstructionsbelowcarefullyandrefertotheimages.
Dangerousoperatingconditionsmayoccurifthelogsarenot
positioned in their correct locations. If the logs are broken
do not use the unit until they are replaced. Broken logs can
interfere with the pilot operation.
2) Spreadvermiculitearoundtheexposedfireboxbase.Thentakesome
embers and spread them over the vermiculite as shown.
IMPORTANT
For LP units the Air Deflector MUST be installed prior
to log installation. See "Conversion from NG to LP"
section in manual for installation instructions.
Vermiculite and Embers
3) Fit log 27-31 into the pins on the rear log tray.
Log kit (Part # 425-930) contains the following pieces:
a) 27-31
b) 27-32
c) 27-33
d) 27-34
e) 27-35
Rear Log
Middle Left Log
Front Log
Middle Right Log
Left Log
f)
27-36
Right Log
g) 902-154
h) 902-179
Embers Lava
Vermiculite
i)
j)
902-153
946-669
Rock Wool
Platinum Embers (supplied with packaged manual)
27-35
27-34
27-36
27-31
27-32
27-33
27-31
4) Fit log 27-32 into the pins on the middle left hand side of the
burner.
1) Carefully remove the logs from the box and unwrap them. The logs
are fragile, handle with care - do not force into position.
27-32
10
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
6) Fit the groove in log 27-34 into the tab on the right side of the burner.
Rest the other end of log 27-34 on the notch in log 27-33.
27-32
27-34
5) Fit log 27-33 into the pins at the front of the burner.
Tab
27-33
27-34
27-33
7) Fit the bottom end of log 27-35 into the pin in log 27-33 and rest the
top end of log 27-35 on the notch in log 27-31.
27-33
27-35
27-33
U32-5 FPI Direct Vent Gas Insert
11
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
9) Place embers along the front of the burner as shown. Ensure not to
cover any burner ports.
27-35
Embers
8) Fit log 27-36 into the pins on logs 27-33 and 27-31.
10) Separate platinum embers and place on the burner just in front of
the logs as shown. Avoid stacking platinum embers.
27-31
27-36
27-33
Platinum Embers
27-36
12
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Completed Log Set Installation
27-34
27-31
27-35
27-32
27-36
27-33
U32-5 FPI Direct Vent Gas Insert
13
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
REGENCY FACEPLATE
& TRIM
INSTALLATION
1) Lay the faceplate panels flat, face down on
something soft so they don't scratch.
2) Take the top faceplate and align the holes
in it with the holes in the side panels. Using
the screws provided, attach from the top of
the panel (the holes in the top panel are
slightlylargerthantheholesinthesidepanel
to facilitate easier installation). Diagram 1.
Diagram 4
Rear View: Trim Assembly
Diagram 2
5) Connect the fan switch wires by taking the
black and red wires with the male ends (in
the grey harness) and connect them with
the wire connectors from the fan speed
control.
6) ConnecttheON/OFFswitchwiresbytaking
theblackandredwireswiththefemaleends
and connect them to the ON/OFF switch.
Diagram 5
11) Push the Regency® logo plate into the
two holes in the bottom left corner of the
faceplate.
7) Tuckthewiresintothefaceplatetokeepthem
awayfromtheinsertusingtheclipprovided.
Attach the clip to the rear of the faceplate to
ensure that the wires do not touch the side
of the unit. Diagram 3.
Rear View: Faceplate Assembly
Diagram 1
Hint: Don't tighten the screws down
completely at this point, continue on with
steps 3 and 4 and do a trial fit to the unit.
Make any necessary adjustments and
when it fits properly then tighten down the
screws.
Hearth Trim Option: Hearth Trim is an
option that can be used to finish off the
installation when the bottom of the fireplace
is higher than the hearth or to raise the
fireplace. Attach the Hearth Trim to the
bottom of the faceplate side panels with the
screws provided. See Diagram 1.
Diagram 3
8) The power cord should be run behind the
faceplate panel.
9) Attachthebrasstrimtothefaceplatebydrilling
a1/8"holethroughintothefaceplateusingthe
hole in the trim as a guide. Fasten the trim to
the faceplate panels using the plated screws.
Diagram 4.
3) Using the connectors provided, join the left
side trim (with the ON/OFF switch) to the
top trim. Diagram 2. Connect the right side
trim to the top trim.
10) Attach the faceplate panels to the insert
body using the 4 remaining black screws.
Diagram 5.
4) Place the trim on the assembled faceplate
panels, aligning the wire connections from
the switches with the notch on the left side
panel.
14
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Use the hook to pull the spring out until you
can put the hook into the slot on the bottom
door bracket. Repeat for 2nd spring. See
diagram 3.
STANDARD
FLUSH DOOR
OPTIONAL DOUBLE
SCREEN DOORS
1) Pulloutthetop
The standard flush door comes with a black
frame. To install the frame, simply hook the top
door flange onto the top of the unit and swing
the door towards the unit, diagram 1. Be careful
that the glass gasket does not roll up; there
must be a gap between the gasket and the door
lip to ensure that the door sits securely on the
unit. Diagram 2.
louver.
2) Center the
screen door
and hook over
the flush door.
Diagram 3
To remove the flush door, reverse the above
steps.
3) Open the screen door(s) and secure the
screen door to the flush door front with 2
clips on the bottom left and right side.
NOTE: The chain must rest on TOP of the gas
inlet pipe never under it.
Diagram 1a
Clip locations
OPTIONAL
FLUSH TRIM
Clip installed
on right side.
Attach 2 round magnets to the back of the top
trim piece and the other 2 to the bottom trim
piece, then attach trim to the top and bottom
of Flush door.
FLUSH LOUVERS
1) The top louver is held in place by friction fit,
if the louver needs to be adjusted; bend the
bracket out as shown in the diagram.
Diagram 1b
Diagram 2
U32-5 FPI Direct Vent Gas Insert
15
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
2) InstalltheSpringHingesontheleftandright
side of the bottom of the Firebox using 2
screws per hinge.
BAY LOUVERS
1) Install top louver by sliding the two bracket
clips into the brackets located on top of the
baydoor.Seebelow.Thefittedlouverleaves
a small gap between faceplate bottom and
louver top.
3) PlacetheBottomLouvernearthehinge.Flip
hinge over the Bottom Louver and secure
using 3 screws.
Hinge
Location
SIT Extension knobs for Bay Front only.
Removing Bay Door
Bottom Louver
ToremoveonlytheBayDoor-useascrewdriver
to unclip the Bay Bottom bracket from the flush
door and then swing up and unhook from the
top flush door flange.
2) Install bottom louver by sliding the two
bracket clips into the brackets located
underneath the bay door. Secure with 1
screw into each Bottom Louver Mounting
Bracket as per diagram below. Use the
bottom hole in the bracket.
To remove the Bay Door & the Flush Front
together, pull the hook from the slot in the
bottomdoorbracketundertheunit(seeStandard
Flush Door instructions above). Then pull the
Bay Door and Flush door out and lift off of the
flange at the top of the unit.
OPTIONAL BAY DOOR
The Bay louvers MUST be used
with the Bay glass option.
The optional Bay door is an overlay on the
flush front. The standard flush door and glass
must remain on the unit. Hook the top of the bay
door over the flush door flange and swing the
bottom against the bottom flange of the flush
door. Press down on the Bay Bottom bracket
and push in until it clips behind the bottom of
the flush front.
Note: Ifanymaintenanceetc.mustbedone
in the firebox, first remove the Bay
louvers and door.
OPTIONAL BAY TRIM
Attach the 4 supplied magnets, each to the
back of the top and bottom trim pieces (space
out evenly) and attach trim to the top and bot-
tom of Bay door.
3) Slide the valve extension knobs onto the
valveknobs.Matcheachextensionknobwith
the corresponding valve knob. Extension
knobs are for Bay Front installations
only.
16
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
CONVERSION KIT #514-969 FROM NG TO LP
for P36D-1 / P36-4 / U32-5 / U37-1 using SIT 820 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
6) Pull off the pilot cap to expose the pilot
For P36D-1 / P36-4 Only:
Each Kit contains one LPG
Conversion Kit and one DC
Sparker Kit.
orifice.
5) Remove the 2 screws holding the Burner
Assembly to the firebox base. Push the
Burner Assembly to the left and lift out.
Conversion Kit Contains:
Qty.
Part #
Description
1
904-390
904-529
918-590
Burner Orifice #52
5/32" Allen Key
Decal "Converted
to LPG"
1
1
1
1
908-528
910-037
Red "LPG" label
LPG Injector
(Pilot Orifice)
Remove the 2 screws, push Burner Assembly
to the left and lift out.
1
918-481
Instruction Sheet
7) Unscrew the pilot orifice with the allen
key; then replace with the LPG pilot
orifice and the pilot cap, provided in the
kit.
For U32-5 Only:
DC Sparker Kit Contains:
Qty. Part # Description
5a) Remove the grate by removing the
1
1
1
1
2
820-475
820-476
904-153
904-330
904-531
Bracket DC Sparker
Bracket DC Sparker
Washer #8 External Star
Nut 8-32 Hex
Bushing Split Plastic
0.500 in.
screws on each side of the grate.
1
2
1
1
1
904-543
904-553
910-073
910-074
910-078
Screw 8-32 x 3/4 Pan
Head
Screw #8 x 1/2 Type "B",
Black Oxide
Spark Generator Battery
Holder
Spark Generator Switch
C/W Wire
Remove the 2 screws
holding the grate in position.
8) Remove burner orifice with a 1/2"
wrench. Use another wrench to hold on
to the elbow behind the orifice. Discard
orifice.
Battery Size AA
5b) Remove the Burner Tray by removing
the screws on each side of the tray.
Push the tray to the left and lift up.
Energizer En91
2
1
910-199
910-903
Clip Wire Holder
Wire Fan To Power Cord
Ground 30 in.
904-781
904-782
Velcro Hook, Black
Velcro Hook, Black
Installation of LPG
Conversion Kit:
Burner Orifice
1) Shut off the gas supply.
Remove the 2 screws,
push Burner Tray to the left, and lift off.
2) Remove the louvers (and bay door if it is
installed).
IMPORTANT
3) Open the flush door and remove the
Before re-installation of the burner (once
the LP conversion is complete), the air
deflector must be installed. See step 18a.
door.
4) Remove the logs and embers (if already
installed).
U32-5 FPI Direct Vent Gas Insert
17
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
9) Reinstall new burner orifice LPG
16) Verify that if the conversion is from
NG to LPG, the screw must be re-
assembled with the red o-ring visible
(Fig. 5).
Installation of the DC Sparker:
stamped #52 and tighten.
21) Locate the Piezo Ignitor situated at the
10) Turn control knob to the “OFF” position.
side of valve.
LPG Configuration
Red o-ring visible
Piezo
Ignitor
11) Remove the black
protection cap by hand
from the hi-low knob
(Fig.1).
Fig.5
Fig. 1
17) Re-assemble the black protection
22) Remove the Piezo Ignitor by unscrewing
the nut at the back of the mounting
bracket.
cap (Fig. 6).
12) Insert a 5/32” or 4mm
Allen wrench into the
hexagonal key-way
of the screw (Fig.
Ignitor
Wire
2), rotate it counter-
clockwise until it is free
and extract it.
Fig.2
Fig. 6
Piezo
Ignitor
18) Reverse steps 6 - 1.
13) Check that the screw is clean and if
necessary remove dirt.
For U32-5 Only:
23) Disconnect the ignitor wire from the
Piezo Ignitor and connect it to the DC
Sparker.
18a) Install the air deflector to the back wall of
14) Flip the screw (Fig. 3).
the firebox using 2 screws.
DC
Sparker
Fig.3
Ignitor
Wire
15) Using the Allen wrench
as shown in Fig.4, rotate
the screw clockwise until
snug, do not overtighten.
Air Deflector
24) Connect the DC spark generator wires
to the SIT Valve with the screw, which is
provided in the kit.
WARNING!
Also check that the pilot and main
burner injectors are appropriate for
the gas type.
Fig.4
WARNING!
Do not over tighten the screw.
Recommended to
19) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
grip the wrench by the short side.
20) Replace yellow "NG" label with red
"LPG" label.
18
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
25) Locate the ground lug.
28) Install the 1/2" bushing to the heat
32) Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which is
provided in the kit.
shield.
For P36D-1 / P36-4 Only:
25a) By the receptical box, left of the unit.
33) Find a location which is not too hot and
is easy to reach for changing the battery.
Note: It should be kept away from the
29) Plug the DC spark generator wires to the
DC Sparker.
chain.
Chain
For U32-5 Only:
25b) Located on the left side of the unit.
34) Tie up the loose wires with the wire clip.
30) Connectthe groundwiretotheDCSparker
mounting bracket.
26) Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
Ground
wire from
kit
35) Check for gas leaks.
36) Check inlet and outlet pressures.
37) Check operation of flame control.
27) Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
31) Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
38) Check for proper flame appearance and
glow on logs.
Heat Shield
NOTE: The battery in the DC Sparker
Box will need to be replaced an-
nually.
Battery
Compartment
U32-5 FPI Direct Vent Gas Insert
19
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
FULL SCREEN DOORS
3) Completely secure the full screen door frame to the unit by securing
1) Hold the full screen door frame up against the unit in order to make
4 screws to the Left and Right Side Trims.
the following wire connections.
Pull the ON/OFF connector wires from the firebox and connect them
to the switch.
Connect the fan switch wires with the wire connectors from the fan
speed control. Place clips over wires and tuck into side trim.
.
NOTE: When mounting the full screen door frame to the unit, the
inside flange of the side trims are to fit over the inner side of the unit
flange and NOT next to the outer side of the unit flange.
2) Lift unit up slightly and push down on the corners of the Bottom Trim
Bracket and slide under unit. Unit should touch tabs on Bottom Trim
Bracket.
Inside flange of Side Trim goes over
the inner side of the unit flange.
Push in Corners
Bottom Trim Bracket
20
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
4) Install Spring Hinges on the Left and Right Side of the bottom of the
7) Install the Left and Right Side Screen Doors in the fully open position
firebox using 2 screws per hinge.
by placing over top of the hinges on the full screen door frame.
Hinge
5) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and
secure with 3 screws.
Screen Door
Hinge Location
Bottom Frame
8) Close screen doors.
NOTE: If you find that the doors do not align properly, adjust the
hinges on the door(s) by loosening them and adjust accordingly.
6) The Top Frame is held in place by friction fit, if the frame needs to
be adjusted; bend the bracket accordingly.
Top Frame
U32-5 FPI Direct Vent Gas Insert
21
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
HAMPTON® CAST
FACEPLATE INSTALLATION
5) Connect the ON/OFF switch wires by taking the black and red wires
with the blue female ends thru the hole provided and connecting
them to the ON/OFF switch.
1) Lay the faceplate panels flat, face down on something soft so they
don't scratch.
2) Attach the side filler brackets to the left and right sides using 3 screws
and washer per side.
NOTE: There are filler brackets specifically for each side. The way
to differentiate this is that on the side of the brackets there are 2
mounting holes. The side where there is a 7/16" gap from the top
of the bracket to the mounting hole, must face the top.
6) Connectthefanswitchwiresbytakingtheblackandredwireswiththe
male ends (in the grey harness) thru the hole provided and connect
them with the wire connectors from the fan speed control.
7) Insert wires into the strain relief and install into switch box
assembly.
3) Attach the right and left cast sides to the top using 2 screws per
side.
8) Place the switch box assembly over the boss on the rear left side
piece and secure with one screw.
Switch Box Assembly
Ensure that the
top and sides are
aligned.
Boss on rear left side piece.
9) Tuck the wires into the faceplate to keep them away from the insert
using the clip provided. Attach the clip to the rear of the faceplate to
ensure that the wires do not touch the side of the unit.
4) Use a measuring tape to ensure that the distance between the left
and right side pieces is 28" (711mm).
28"
10) The power cord should be run behind the faceplate panel.
22
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
11) Mount the cast faceplate panels onto the insert body, sliding the
side filler brackets into the space between the glass and the firebox.
Secure using the 4 remaining black screws, 2 per side.
HAMPTON® CAST
GRILL INSTALLATION
Slide side filler bracket
into gap between
glass and fire box.
Before the grills are installed, a grill stop bracket needs to be put in
place.
1) The U32 grill stop bracket is installed in the bottom left corner just
under the firebox as shown below.
U32 Grill
Stop
Bracket
2) Place top grill into brackets located inside top of firebox as shown.
Bracket inside
top of firebox.
U31 ONLY:
Install the glass trim by inserting the side hooks on the glass trim
into the 4 slots between the faceplate and the glass. Push the
glass trim down firmly with both hands to lock into place.
Bracket
Top Grill
Side Hook
Slots
Note: The top grill should be placed with the curved
cut-out facing up.
3) The bottom grill, shown in the diagram below, has 2 hinges that are
attached to the lip on the bottom of the unit. Secure using 2 screws
per hinge.
12) To put on the Hampton® logo, peel the sticker from the back of the
logo and place it centered on the bottom left hand corner of the
faceplate.
Hampton® Logo
Left Side
Faceplate
U32-5 FPI Direct Vent Gas Insert
23
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
THE KENSINGTON®
FRONT INSTALLATION
IMPORTANT: Please use the gloves provided when handling the Kensington® Front to avoid fingerprints.
1) Place the Kensington® Front up against the unit , but do not secure.
2) Mount the Kensington® Front onto the firebox by securing in place
Make the following wire connections:
using 4 screws, 2 per side.
Connect the fan switch wires by taking the black and red wires with
the male ends (in the grey harness) and connect them with the wire
connectors from the fan speed control.
Kensington®
Front
Connect the ON/OFF switch wires by taking the black and red wires
with the female ends and connect them to the ON/OFF switch.
Tuck the wires into the faceplate to keep them away from the insert
using the clip provided. Attach the clip to the rear of the faceplate to
ensure that the wires do not touch the side of the unit.
The power cord should be run behind the faceplate panel.
Left Side
Shown
Screws
3) Slide the Tabs on the Blanking Plate into the slots located on Front
and secure using 2 screws.
Blanking Plate Tabs
Kensington®
Front
Blanking
Plate
Screw
Screw
24
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
THE KENSINGTON®
2-PANEL DOOR INSTALLATION
3) Hook the Left Side Screen Door to the Door Frame by placing the
door hinges (top & bottom) over the pins on the Door Frame. Repeat
for Right Side Screen Door.
1) Install the Sub-Frame by hooking the top flange onto the top of the
Glass Door and swing the Sub-Frame towards the unit. Pull out the
hooks which already secure the Glass Door and place them thru the
holes in the bottom of the Sub-Frame to secure both the Glass Door
and Sub-Frame in place together.
Note: It will be easier to put the Screen Door in place by starting with
the bottom hinge.
Glass Door
Sub-Frame
Sub-Frame
Hook
Pin on Door Frame
Left Side Door
Note: If you find that the Left or Right Side Screen Door is lower then
the other, use the spacer provided to help align the Doors.
The spacer is to be placed over the bottom pin before installing the
Screen Door.
2) Mount the 2-panel Door Frame to the flange on Sub-Frame, ensuring
to line up holes. Secure using the 6 screws provided.
Spacer
U32-5 FPI Direct Vent Gas Insert
25
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
THE KENSINGTON®
3-panel Door
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired,
follow the wiring diagram below. FPI offers an
optional programmable thermostat but any
250-750 millivolt rated non-anticipator type
thermostat that is CSA, ULC or UL approved
may be used.
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
Installation
1) Install the Sub-Frame by hooking the top
flange onto the top of the Glass Door and
swing the Sub-Frame towards the unit. Pull
out the hooks which already secure the
Glass Door and place them thru the holes
in the bottom of the Sub-Frame to secure
boththeGlassDoorandSub-Frameinplace
together.
1) Clocking the appliance to ensure the
correct firing rate (rate noted on label) at
15 minutes.
2) Ifrequired,adjustingtheprimaryairtoensure
that the flame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
3) Check for proper draft.
Wire Size
Max. Length
CAUTION
Glass Door
Sub-Frame
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of
the manufacturer.
Sub-Frame
Hook
CAUTION
Do not connect the millivolt wall
thermostat wires
to the 120V wires.
2) Mount the 3-panel Screen Door / Frame
Assembly to the flange on Sub-Frame,
ensuring to line-up holes. Secure using the
4 screws provided.
OPTIONAL REMOTE
CONTROL
Use the FPI Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fireplace to
that location. Use Thermostat Wire Table.
2) Connectthewiresasperthewiringdiagrams
below.
CAUTION
Do not connect the millivolt
remote control wires for
to the 120V wires.
3) Install3AAAalkalinebatteriesintransmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
26
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
WIRING DIAGRAMS
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/
thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes
Green
Fan
Ground
Neutral
Ground
Live
120V AC
ON
OFF
Black
Red Black
Pilot
Assembly
Rotary Speed
Control
Minimum Convection
Air Temp. Switch
To
Thermocouple IN
Thermocouple
In
Piezo
Ignitor
Black
Red
ON
Gas
In
Burner
F
F
O
White
Brown
OFF
"S.I.T" Valve
OFF ON
CAUTION:
Label all wires prior
Thermostat
(Optional)
(Millivolt)
Remote
Receiver
(Optional)
(Millivolt)
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous operation.
Remote Transmitter
(Optional)
WARNING:
Electrical Grounding Instructions
This appliance is equipped with a three pronged (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly grounded three-
prong receptacle. Do not cut or remove the grounding prong from this plug.
U32-5 FPI Direct Vent Gas Insert
27
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
For PROPANE Units and Units Equipped with DC Spark Boxes*
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.
28
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
1) Open the bottom louver assembly
The glass panel may require cleaning
after the unit has cooled down. DO
NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
OPERATING
2) If the control knob is in the "OFF" position
INSTRUCTIONS
proceed to Step 5.
Beforeoperatingthisappliance,proceedthrough
the following check list.
3) Push in gas control knob slightly and turn
clockwise to "OFF". Knob cannot be turned
from"PILOT"to"OFF"unlessknobispushed
in slightly. Do not force.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and
will disappear in a few minutes as
the glass heats up.
1) Read and understand these Instructions
before operating this appliance.
4) Wait five minutes to allow gas, that may
have accumulated in the main burner
compartment, to escape. If you do smell
gas, follow the instructions on the front of
this manual. If you don't smell gas continue
on to the next step.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the first few fires, a white film
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the film will bake on and
become very difficult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
4) Make sure the glass door is in place. Never
operate the appliance with the door glass
removed.
5) Turn the gas control counter clockwise to
"PILOT".
6) Push in control knob all the way and hold
in. Continually push and release the black
button on spark igniter until pilot lights.
Continue to hold the control knob in for
approximately one minute, then release
the gas control knob. The pilot flame should
continue to burn. If the pilot does not remain
lit, repeatoperationallowingalongerperiod
before releasing gas control knob.
5) Verify that all venting and the cap is
unobstructed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
7) The unit should never be turned off and on
again without a minimum of a 60 second
wait.
AUTOMATIC
CONVECTION FAN
OPERATION
7) Turn gas control knob counter clockwise to
"ON".
8) When lighting the appliance, the inside of
the glass may fog up. This will burn off after
a few minutes of operation.
8) Use the rocker switch to operate main
Thefanoperatesautomatically,turntheknobon
the side of the faceplate to adjust to the desired
speed. The fan will turn on as the stove comes
up to operating temperature. After the unit has
been turned off and the unit cooled to below a
useful heat output range the fan will shut off
automatically.
burner.
9) Rotate the variable flame control to adjust
DO NOT BURN THE APPLIANCE
WITH THE GLASS ASSEMBLY
REMOVED.
the flame height higher or lower.
10) Close the bottom louver assembly.
SHUTDOWN
PROCEDURE
NORMAL OPERATING
SOUNDS OF
1) Use the rocker switch to turn off the main
GAS APPLIANCES
burner.
2) Open the bottom louver assembly.
It is possible that you will hear some sounds
fromyourgasappliance.Thisisperfectlynormal
due to the fact that there are various gauges
and types of steel used within your appliance.
Listedbelowaresomeexamples.Allarenormal
operatingsoundsandshouldnotbeconsidered
as defects in your appliance.
LIGHTING
3) Push in the gas control knob slightly and
turn clockwise to "OFF". Do not force.
PROCEDURE
4) Disconnect all electric power and gas to the
IMPORTANT
appliance if service is to be performed.
To ignite or reignite the pilot, you must first
release the tension springs below the door.
Blower:
FIRST FIRE
Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not be operated with the tension springs
unattached.
FPI gas appliances use high tech blowers to
push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.
The first fire in your stove is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you
burn your fireplace for at least four (4) hours
the first time you use it with the fan on. When
first operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
NOTE:Forallpropaneunitsandunitsequipped
with electric spark boxes, see "Copy of Lighting
Plate Instructions" section for more details.
Burner Tray:
The burner tray is positioned directly under the
burnertube(s)andlogsandismadeofadifferent
gauge material from the rest of the firebox and
body.Therefore,thevaryingthicknessesofsteel
will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
IMPORTANT: Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
U32-5 FPI Direct Vent Gas Insert
29
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
sounds. You should also be aware that as there
COPY OF LIGHTING INSTRUCTION PLATE
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fireboxes.
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)
Blower Thermodisc:
WARNING:Ifyoudonotfollowtheseinstructionsexactly,afireorexplosionmayresultcausingpropertydamage,
personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance
or additional information consult a qualified installer, service agency or gas supplier.
A) This appliance has a pilot which must be lighted by hand, following the instructions below exactly.
B) BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.
When this thermally activated switch turns ON
it will create a small "clicking" sound. This is the
switch contacts closing and is normal.
Pilot Flame:
While the pilot flame is on it can make a very
slight "whisper" sound.
WHAT TO DO IF YOU SMELL GAS
-
-
-
-
Do not try to light any appliance
Do not touch any electric switch, do not use any phone in your building
Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
C) Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to
repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dullclickingsoundmaybeaudible,thisisnormal
operation of a gas regulator or valve.
D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control which has been under water.
E) This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures
keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner
and control compartment clean. See installation and operating instructions accompanying appliance.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
LIGHTING INSTRUCTIONS
STOP! Read the safety information above on this label.
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK:
1) Push in gas control knob slightly and turn clockwise
“OFF”. Knob cannot be turned from “PILOT” to “OFF” unless
knob is pushed in slightly. Do not force.
FOR ALL PROPANE UNITS AND
UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:
to
1) Push in gas control knob slightly and turn to “PILOT” position.
OFF
PILOT BURNER
VEILLEUSE
2) Push in control knob all the way and hold in until the pilot lights
up. Continue to hold the control knob in for about 20 seconds
after the pilot is lit. Release knob.
MAINTENANCE
INSTRUCTIONS
1) Always turn the gas valve to off before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and
vacuuming at least once a year. When
cleaning the logs, use a clean soft paint
brush as the logs are fragile and easily
damaged.
THERMOPILE
ELEMENT
Gas Inlet
3) Push in gas control knob slightly and turn to "ON" position.
THERMO-
ELECTRIQUE
4) Turn ON the flame switch.
2) Wait five (5) minutes to clear out any gas. If you then smell gas
STOP! follow “B” in the safety information above on this label. If
you don’t smell gas, go to the next step.
Gas Inlet
3) Turn knob on gas control counterclockwise
to “PILOT”.
4) Push in control knob all the way and hold in. Immediately push
black button on spark igniter until pilot lights. Continue to hold the
control knob in for about 1/2 minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain lit. If it goes out,
repeat steps 3) and 4).
If knob does not pop up when released, stop and immediately call
your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control
knob to “OFF” and call your service technician or gas supplier.
5) Turn gas control knob counterclockwise
6) Use rocker switch to operate main burner.
to “ON”.
2) Clean (never when unit is hot) appliance,
door and louvers with a damp cloth. Never
use an abrasive cleaner. The gold louvers
(and optional gold door) may be scratched
if abrasives are used to clean them.
TO TURN OFF GAS APPLIANCE
1) Turn off the flame switch.
2) Push in the gas control knob slightly and turn clockwise
3) Turn off all electric power to the appliance if service is to be performed.
You may shut off the pilot during prolonged non use periods to conserve fuel.
to “OFF”. Do not force.
The heater is finished in a heat resistant
paintandshouldonlyberefinishedwithheat
resistantpaint(notwithwallpaint). FPIuses
StoveBrite Paint - Metallic Black #6309.
DO NOT REMOVE THIS INSTRUCTION PLATE
918-474a
6) Each time the appliance is lit, it may cause
condensation and fog the glass. This
condensation and fog is normal and will
disappear in a few minutes as the glass
heats up.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY
AWAYTOAVOIDBURNSORCLOTHING
IGNITION.YOUNGCHILDRENSHOULD
BE CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
3) Make a periodic check of burner for proper
position and condition. Visually check the
flameoftheburnerperiodically,makingsure
the flames are steady; not lifting or floating.
If there is a problem, call a qualified service
person.
Never operate the appliance without the
glass properly secured in place or with
the door open.
4) The appliance and venting system must be
inspected before use, and at least annually,
byaqualifiedfieldserviceperson, toensure
that the flow of combustion and ventilation
air is not obstructed.
7) Donotusethisapplianceifanyparthasbeen
under water. Immediately call a qualified
service technician to inspect the appliance
andtoreplacenaypartofthecontrolsystem
and any gas control which has been under
water.
CAUTION: ANY SAFETY SCREEN OR
GUARDREMOVEDFORSERVICINGAN
APPLIANCEMUSTBEREPLACEDPRIOR
TO OPERATING THE APPLIANCE.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers but do
not block the pilot.
8) Periodically check the pilot flames. Correct
flamepatternhasthreestrongblueflames:1
flowing around the thermopile and 1 around
the thermocouple, and 1 flowing across the
rear of the burner (it does not have to be
touching the burner).
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
30
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
GOLD-PLATED TRIM
The 24 carat gold plated finish on the trim
requires little maintenance, and need only be
cleanedwithadampcloth.DONOTuseabrasive
materials or chemical cleaners, as they may
harm the finish and void the warranty. Clean
any fingerprints off before turning the unit
on. If the top louvers start to discolour,
check the door gasket seal and replace if
necessary.
1) Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or
streaks, and in extreme cases, holes.
These components should be replaced
immediately.
Top View of pilot flame
DOOR GLASS
Incorrectflamepatternwillhavesmall, probably
yellow flames, not coming into proper contact
with the rear of the burner or thermopile.
YourFPI insertissuppliedwithhightemperature,
5mmNeoceramceramicglassthatwillwithstand
the highest heat that your unit will produce. If
your glass requires cleaning, we recommend
using an approved glass cleaner available at
all authorized dealers. Do not use abrasive
materials. Do not clean the glass when hot.
2) Remove the Termination Cap, and shine a
flashlight down the Vent. Remove any bird
nests, or other foreign material.
3) Check for evidences of excessive
condensation,suchaswaterdropletsforming
in the inner liner, and subsequently dripping
outthejoints,Continuouscondensationcan
cause corrosion of caps, pipe, and fittings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to
cold weather.
Intheeventthatyoubreakyourglassbyimpact,
purchase your replacement from an authorized
FPI dealer only, and follow our step-by-step
instructions for replacement.
Warning: Do not operate appliance
withglasspanelsremoved,cracked
orbroken.Replacementoftheglass
should be done by a licensed or
qualified service person.
4) Inspect joints, to verify that no pipe
sections or fittings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
Top View of pilot flame
If you have an incorrect flame pattern, contact
your FPI dealer for further instructions.
Caution: Wear gloves when removing
damaged or broken glass.
LOG REPLACEMENT
Flush Glass Replacement
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.
Remove the flush door front (as per instructions
in section "Standard Flush Doo"). Remove the
4 glass clips from each corner. Slide in the new
replacement glass. Push the 4 glass clips back
onto the frame.
NOTE: Improper positioning of logs may
create carbon build-up and will alter the unit’s
performance which is not covered under
warranty.
GLASS GASKET
If the glass gasket requires replacement use
glass gasket (Part # 936-265) for the Bay Front
and a tadpole gasket for the Flush Front (Part
# 936-155).
U32-5 FPI Direct Vent Gas Insert
31
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
10) Unplug the wires from the fan motor (from
TO REMOVE FAN:
Bay Glass Removal
inside the stove).
1) Turn the unit off and allow it to cool to room
1) Remove the door from the unit and place
11) LiftFanAssemblyoffofthe2pins,tipforward
temperature.
on a soft surface to prevent scratching.
and pull through firebox opening.
2) Unplug or disconnect power source to
2) Removethenutsholdingtheglassretainers
12) Disconnect green wire from power cord.
stove.
in place.
3) Remove glass front (see section "Standard
3) Remove the glass retainers (sides, top and
Flush Door.")
bottom).
4) Remove logs and brick panels, if used.
4) Replace the glass. The glass must have
gasketing around it.
5) Remove the grate by loosening the two
screws and sliding the grate out.
5) Reverse the previous steps, replace the
retainers and fasten with the nuts but do not
over tighten, as this can break the glass.
6) Remove the burner/front log support
assembly by removing the 2 screws and
lifting it out.
6) Replace door on the stove and check the
seal.
Grate screws
7) Remove the 2 screws holding theAir Intake
Hood to the rear firebox wall and lift out.
Replacing fan:
FAN MAINTENANCE
Reverseabovesteps. Hintforpushingfandown
onto pins - rub a bit of dish soap on the grommet
so it will slide more easily onto the pin.
8) Remove the 10 screws holding the Access
Ifyourfanrequiresmaintenanceorreplacement,
accesstothefanisthroughtheplateontherear
wall of the firebox. NOTE: the unit MUST NOT
be operated without the fan access panel
securely in place.
Panel in place.
Check to make sure the fan is seated properly
on the pins, this is very important- try to move
thefanbackandforth, thereshouldbenonoise,
if there is check that the grommets haven't
come loose.
Caution: Label all wires prior to
disconnectingwhenservicingcontrols.
Wiring errors can cause improper and
dangerous operation. Verify proper
operation after servicing.
Seal fan access panel using high temperature
silicone (sparingly).
9) Remove the Fan Air Duct by loosening the
3 screws, squeeze the sides together to
remove.
32
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
11) Push the valve assembly to the left and lift 5) Reconnect the pilot tube nut with a 7/16"
VALVE REPLACEMENT
the entrire assembly out.
wrench.
1) Shut off the gas supply.
6) Re-attach the valve mounting bracket to the
valve tray.
2) Remove the louvers (and bay door if it is
on).
3) Open the flush door and remove the door.
4) Remove the logs and brick panels.
5) Remove the grate by loosening the two
screws and sliding the grate out.
12) Removethevalveby removingthe4screws
in the base of the valve tray.
7) Scrape off the old gasket from the floor of
the firebox and from the valve tray.
8) Install a new gasket and reinstall the
valve assembly.
Grate screws
Note: Failure to install a new gasket may
severely affect the appliance performance.
6) Remove the burner assembly by removing
the 2 screws and lifting it out.
9) Reinstall the 11 hold down screws.
13) Undo the pilot tube from the valve with a
10) Hook up the TP, TH, and TP/TH wires to
7/16" wrench.
the appropriate connections on the valve.
14) Undo the quick drop out thermocouple nut
11) Reinstall the burner assembly.
on the valve with a 9mm (metric) wrench.
15) Undo the "gas out" flare nut with a 13/16"
wrench.
16) Undothe"gasout"flarefittingwithan11/16"
7) Remove the 2 screws holding theAir Intake
wrench.
Hood to the rear firebox wall and lift out.
17) Remove the valve mounting brackets.
Note: when installing the burner assembly
be sure to slide the aeration adjustment wire
through the hole in the base of the burner
tray.
8) Disconnect the inlet gas line.
9) Disconnect the TP wire, the TH wire, and
the TH/TP wire from the valve.
12) Install the grate.
Hint: If you are using black pipe, ensure that
there is a union by the valve, otherwise removal
will be almost impossible.
10) Removethe11Phillipsheadscrewssecuring
thevalvetrayinplace.andthenlifttheentire
assembly out.
13) Hook up the gas line and check for gas
leaks with a soap and water solution or a
gas leak detector. (Do not use open flame
for leak testing.)
INSTALLING VALVE
13) Fire up the unit temporarily and check the
1) Re-attach the valve mounting brackets to
manifold pressure.
the valve.
14) Reinstallthevermiculite,embers,rockwool,
2) Reconnect the "gas out" flare fitting with an
logs and brick panels as needed.
11/16" wrench.
15) Close the door and replace the louvers.
3) Reconnect the "gas out" flare nut with a .
13/16" wrench.
16) Fire up the unit again and check for proper
flame appearance and glow on logs.
4) Reconnectthequickdropoutthermocouple
nut with a 9mm wrench.
U32-5 FPI Direct Vent Gas Insert
33
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
MAIN ASSEMBLY
Part #
Description
Part #
Description
1) 420-122
2) 420-142
422-518/P
Fan Access Panel
Gasket - Fan Access Panel
Fan Assembly:
Fan Motor (120 V)
Power Cord (120 V)
Wire Harness (intermediate)
Thermodisc-Fan Auto ON/OFF
Fan Switch Cover
Thermodisc Bracket
Flue Restrictor
41) 420-157
42) 420-054
43) *
Gasket - Transition Box Bottom
Gasket - Transition Box Top
Stove Top
3) 910-215/P
5) 910-750
910-752
44) 420-048
45) *
Thermal Insulation
Adaptor Stop
46) *
47) *
48) 320-518
50) *
Adaptor Holding Brkt-Left
Adaptor Holding Brkt-Right
Flue Adaptor Assy
7) 910-142
8)
9)
*
*
Insulation Hold Down Brkt
10) 420-140
12) *
Air Hood
Levelling Bolt 5/16 x 3" Hex Hd
Jack Chain
51) 420-170
52) 420-171
53) 420-172
Top Fan Air Channel
Upper Fan Air Channel
Lower Fan Air Channel
13) *
14) 948-045
15) 948-247
16) 948-025
17) *
Spring Lever Handle
Door Extension Spring
Wire Holder Clip
*Not available as a replacement part.
18) *
19) *
Strain Relief
Grommet for Power Cord
Conversion Kit to Propane
Logo Plate - Hampton®
Manual
514-969
948-220
918-677
21) 420-920
420-922
FlushLouvers (Set) - Black/Gold
Flush Louvers (Set) - Black
FlushLouvers (Set) - Black/Steel
420-923
25) 420-940
420-938
Bay Louvers (Set) - Black/Gold
Bay Louvers (Set) - Black
Bay Louver (Set) - Black/Steel
420-942
422-901
422-902
422-903
Brick Panel Set - Standard Brown
Brick Panel Set - Standard Red
Brick Panel Set
- Herringbone Brown
33) *
Brick Panel - Right Side
Brick Panel - Left Side
Brick Panel - Back
Brick Clip
34) *
35) *
36) 400-090
34
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
BURNER ASSEMBLY & LOG SET
Part #
Description
423-574/P
423-576/P
Valve Assembly - NG
Valve Assembly - LP
Valve - SIT NG / LP
Ignitor Piezo and Nut
Valve Tray
Burner Orifice Nat. Gas #37
Burner Orifice LP # 52
Orifice Gasket
52) 910-478
53) 910-190
55)
*
58) 904-240
904-390
936-170
66) 910-038
910-039
Pilot Assembly - 3 Flame (NG)
Pilot Assembly - 3 Flame (LP)
Pilot Holder
67)
*
68) W840470
Pilot Assembly Gasket
425-930
Log Set
70) 420-143
71) 402-526
72) 402-519
Valve Tray Gasket
Grate/Diffuser Assy
Burner Assembly (NG/LP)
Log Tray Mount Bracket
Log Tray Rear
73)
74)
*
*
90) 910-421
91) 910-422
Pilot ON/OFF 3" (SIT)
Extension Knob
HI/LOW 3" (SIT)
Extension Knob
*Not available as a replacement part.
U32-5 FPI Direct Vent Gas Insert
35
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
BAY & FLUSH FRONT ASSEMBLY
Part #
Description
Bay Door
Complete Bay Door with Black Trim
Glass Retainer Side (Top & Btm)
Glass Retainer Front (Top & Btm)
420-931
102) *
103) *
106) 940-315/P Side Glass
107) 936-243 Gasket
108) 940-314/P Center Glass
110) 420-244
Bay Brick Panel - Steel
111) *
112) 904-196
Door Trim
1" Round Magnet
910-421
910-422
402-956
Pilot On/Off 3" Extension Knob (SIT)
FlameHi/Low3"Extension Knob (SIT)
Gold Trim Bay Front
*Not available as a replacement part.
Flush Door
422-530
Complete Flush Door Assy
112) 904-196
1" Round Magnet
135) 940-307/P Flush Glass
137) 904-691
139) 936-155
U Clip
Tadpole Glass Gasket
422-943
171) 512-546
173) 430-133
904-712
Double Screen Door (Optional)
Door Latch Assembly
Handle
U-clip for frame
36
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
FACEPLATE ASSEMBLY
Part # Description
Part # Description
180) 400-950 Hearth Trim 1" - Regular
181) 320-940 Hearth Trim 1" - Oversize
180) 400-926 Hearth Trim 2" - Regular
181) 320-942 Hearth Trim 2" - Oversize
180) 400-928 Hearth Trim 4" - Regular
181) 320-944 Hearth Trim 4" - Oversize
180) 400-959 Hearth Trim 6" - Regular
181) 320-946 Hearth Trim 6" - Oversize
402-919
Complete Faceplate (Set) Contour
with Black Trim-Oversize
51) *
59) *
60) *
Faceplate Side Right - Oversize
Faceplate Top - Oversize
Faceplate Side Left Assy-Oversize
Trims Pkg. Black - Oversize, Zero Clearance
Faceplate Trim Right - Oversize
Faceplate Trim Top - Oversize
Faceplate Trim Left Assy - Oversize
402-534
65) *
68) *
70) *
190) *
191) *
Screw #8 x 1/2" Black self-tapping
Screw #8 x 1/2" Brass self-tapping
97) 910-246
98) 910-330
99) 904-569
2-way Gold Contact Switch
Fan Speed Control (120 V)
Fan Speed Control Knob (120 V)
199) 948-216 Regency® Logo Plate
*Not available as a replacement part.
400-917
71) *
Complete Custom Faceplate (Set)
Faceplate Side Right - Custom
Faceplate Top - Custom
SEE DETAIL 'A'
SEE DETAIL 'A'
72) *
73) *
Faceplate Side Left - Custom
74) 904-586
Speed Control Knob
c/w Spring Clip
68
95
99
99
70
94
60
92
93
59
96
STANDARD SIZE
FRONT VIEW
OVERSIZE
FRONT VIEW
LOGOPLA
O
G
O
PL
A
TEHERE
E
E
H
E
R
199
65
199
181
51
91
180
SEE DETAIL 'A'
191
147
191
147
145
147
99
402-918
Complete Faceplate (Set)
Standard Contour with Black Trim
97
98
144
147
91) *
Faceplate Side Right - Standard
Faceplate Top - Standard
Faceplate Side Left Assy - Standard
Trims Pkg. - Standard Black
Trim Pkg. - Standard Brass
Faceplate Trim Right - Standard
Faceplate Trim Top - Standard
Faceplate Trim Left Assy - Standard
190
142
143
146
92) *
93) *
DETAIL 'A'
147
147
REAR VIEW
402-532
402-950
94) *
MOLDED FACEPLATE
FRONT VIEW
190
141
95) *
96) *
97) 910-246
98) 910-330
99) 904-569
2-way Gold Contact Switch
Fan Speed Control (120 V)
Fan Speed Control Knob (120 V)
73
98
72
402-933 Complete Faceplate (Set) Molded
141) *
Faceplate Side Right - Molded
Faceplate Top - Molded
Faceplate Side Left -Molded
Mounting Bracket - Right
Filler Bracket
Mounting Bracket - Left
Screw #8 x 3/4" Pan Head
190
74
199
142) *
143) *
144) *
145) *
146) *
147) *
190
190
LOGOPLA
O
G
O
97
PL
A
TEHERE
E
H
E
R
E
71
CUSTOM FACEPLATES
FRONT VIEW
CUSTOM FACEPLATES
REAR VIEW
U32-5 FPI Direct Vent Gas Insert
37
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
HAMPTON® CAST - FACEPLATE ASSEMBLY
Part #
Description
402-971** Cast Faceplates (Set)
187) 910-246
188) 910-330
189) 904-733
Burner On/Off Switch
Fan Speed Control (120 V)
Knob - Black Cast Surround
201) *
202) *
203) *
205) *
194) *
195)
Cast Faceplate - Right
Cast Faceplate - Top
Cast Faceplate - Left
Flush Glass Frame
Mounting Flange
Hampton® Logo Plate
207) 402-981** Cast Grill (Set) - Top & Bottom
*Not available as a replacement part.
** Last digit of part number represents colour:
1=Black Metallic, 5=Enamel Brown
202
187
189
188
194
203
194
201
207
195
205
38
U32-5 FPI Direct Vent Gas Insert
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit
thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a
Excalibur Product. This warranty is not transferable.
The Warranty: Limited Lifetime
The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime
Warranty for five (5) years for parts and subsidized labour* and parts only thereafter.
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date
of purchase and parts only thereafter.
Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating
and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks,
ie. finger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
Electricalandmechanicalcomponentssuchasblowers,switches,wiring,thermodiscs,FPIremotecontrols,spillswitches,thermopiles,thermocouples,pilotassemblycomponents,
and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and
continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.
FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any
item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.
Conditions:
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided
that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of
installation. Reported damage after this time will be subject to rejection.
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated
for manufacturer defect.
The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from
unauthorized service persons or dealers.
At all times FPI reserves the right to inspect product in the field which is claimed to be defective.
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name,
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions:
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.
ie. as products evolve, field modifications or upgrades will not be performed.
FPI will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical
systems such as furnaces, fans, clothes dryer, etc.
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty
on this product.
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.
* Subsidy according to job scale as predetermined by FPI.
U32-5 FPI Direct Vent Gas Insert
39
Download from Www.Somanuals.com. All Manuals Search And Download.
FPI fireplaces are designed with reliability and simplicity
in mind. In addition, our internal Quality Assurance Team
carefully inspects each unit thoroughly before it leaves
our door.
FPIFireplaceProductsInternationalLtd.ispleasedtoextend
this Limited Lifetime Warranty to the original
purchaser of a FPI Product.
See the inside back cover for details.
Register your Regency® online at
Register your Hampton® online at
Installer: Please complete the following information
Dealer Name & Address:______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.:__________________________________________________________
FPI, Regency® and Hampton® are trademarks of FPI Fireplace Products International Ltd.
Printed in Canada
© Copyright 2008, FPI Fireplace Products International Ltd. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Graco Cooktop 3180 User Manual
Grizzly Drill H6363 User Manual
Haier Clothes Dryer GDZ35 1 User Manual
Haier Washer Dryer DWE 3120A User Manual
Heat Glo LifeStyle Indoor Fireplace EM 415 36 User Manual
Hotpoint Dishwasher DC23 24 User Manual
Hotpoint Double Oven BD32B User Manual
Hotpoint Refrigerator HTN17BBT User Manual
iHome Headphones IH K231MS User Manual
Image Treadmill IMTL15991 User Manual