PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
1.1.2. CONSIDÉRATIONS DE SÉCURITÉ  
1.1.  
Safety Considerations  
1.1.1. SAFETY CONSIDERATIONS  
W A R N I N G  
AVERTISSEMENT  
RISQUE DE DÉCHARGE ÉLECTRIQUE  
N'OUVRIR PAS  
RISK OF ELECTRIC SHOCK  
DO NOT OPEN  
EAU ET HUMIDITÉ  
Pour réduire le risque de feu ou de choc électrique, n'exposez pas d'unité pour  
pleuvoir ou l'humidité. Ne faites pas marcher d'unité près de l'eau – comme; la  
baignoire, la cuvette, l'évier ou la cuve de blanchisserie, la cave mouillée ou près  
d'une piscine.  
WATER AND MOISTURE  
To reduce the risk of fire or electrical shock, do not expose unit to rain or  
moisture. Do not operate unit near water – such as: bathtub, washbowl, kitchen  
sink or laundry tub, wet basement, or near a swimming pool.  
STABILITÉ  
Ne placez pas cette unité sur un chariot instable, un éventaire, une parenthèse  
STABILITY  
ou une table. L'unité peut tomber, en provoquant la blessure sérieuse.  
Do not place this unit on an unstable cart, stand, bracket, or table. Unit may fall,  
causing serious injury.  
VENTILATION  
Ne bloquez pas de devant et élevez la ventilation. L'écoulement d'air nécessaire  
est tenu de garantir l'opération sûre et prévient l'unité de sur le chauffage. L'unité  
ne peut pas placé dans un espace fermé où aucune ventilation ou dans suffisant  
n'est disponible.  
VENTILATION  
Do not block front and rear ventilation. Proper airflow is required to ensure  
reliable operation and prevents unit from over heating. Do not place unit in an  
enclosed space where no or insufficient ventilation is available.  
ÉLECTRIQUE  
ELECTRICAL  
Ne vainquez pas le but de sécurité de la prise de courant de pouvoir de bases.  
La corde de pouvoir devrait être mise en déroute pour qu'ils ne seront pas  
probablement marchés sur ou pincés par les articles placés sur ou contre eux.  
Do not defeat the safety purpose of the grounding power plug. The power cord  
should be routed so that it is not likely to be walked on or pinched by items  
placed upon or against them.  
ENTRETIEN  
SERVICING  
N'essayez pas d'assurer l'entretien de cette unité vous-même. En s'ouvrant ou le  
fait d'enlever le haut, le côté et les couvertures arrière vous exposeront aux  
voltages dangereux ou à d'autres hasards.  
Do not attempt to service this unit yourself. Opening or removing the top, side  
and rear covers will expose you to dangerous voltages or other hazards.  
Page 4  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
1.1.3. SAFTY BERÜCKSICHTIGUNGEN  
1.1.4. CONSIDERACIONES DE SEGURIDAD  
W A R N U N G  
ADVERTENCIA  
ELEKTROSCHOCKGEFAHR  
NICHT ÖFFNEN  
GEFAHR DES STROMSCHLAGS  
NICHT ÖFFNEN  
WASSER UND FEUCHTIGKEIT  
AGUA Y HUMEDAD  
Um eine Brand- oder Elektroschockgefahr weitgehend auszuschließen, Gerät  
nicht Regen oder Feuchtigkeit aussetzen. Gerät nicht in der Nähe von Bade-  
oder Waschwannen, Wasch- oder Spülbecken, feuchten Kellern oder  
Schwimmbecken betreiben.  
Para reducir el riesgo de fuego o electrochoque, no exponga la unidad para  
llover o humedad. No haga funcionar la unidad cerca del agua – como; bañera,  
lavatorio, fregadero o tina de lavandería, sótano mojado o cerca de una piscina.  
ESTABILIDAD  
STABILITÄT  
No coloque esta unidad en un carro inestable, soporte, soporte o mesa. La  
unidad puede caerse, causando la herida seria.  
Das Gerät nicht auf wacklige Karren, Ständer, Halterungen oder Tische stellen,  
da es herunterfallen und Verletzungen verursachen könnte.  
VENTILACIÓN  
BELÜFTUNG  
No bloquee delantero y críe la ventilación. El corriente de aire apropiado es  
requerido asegurar la operación confiable y previene la unidad de sobre la  
calefacción. La unidad no puede colocado en un espacio incluido donde ninguna  
ventilación o en suficiente está disponible.  
Vordere und hintere Belüftungsöffnungen nicht versperren. Das Gerät muss  
ausreichend be- und entlüftet werden können, damit es sich nicht während des  
Betriebs überhitzt. Daher darf das Gerät nicht in geschlossenen Räumen  
aufgestellt werden, in denen keine ausreichende Be- und Entlüftung  
gewährleistet ist.  
ELÉCTRICO  
No derrote el objetivo de seguridad del enchufe de poder que da buenos  
conocimientos. La cuerda de poder debería ser derrotada de modo que ellos  
probablemente no sean andados en o pellizcados por artículos colocados sobre  
o contra ellos.  
STROMVERSORGUNG  
Nicht den Schukostecker modifizieren. Das Stromkabel sollte so verlegt werden,  
dass es nicht durch Auftreten oder durch spitze oder scharfe Gegenstände  
beschädigt werden kann.  
REVISIÓN  
WARTUNG  
No intente atender esta unidad usted mismo. Abriéndose o quitar la cumbre, el  
lado y las tapas traseras le expondrán a voltajes peligrosos u otros riesgos.  
Das Gerät nicht eigenmächtig warten. Durch das Öffnen des Geräts (Abziehen  
der oberen, seitlichen und hinteren Abdeckung) setzen Sie sich  
lebensgefährlichen Spannungen aus.  
Page 6  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
1.2.  
System Requirements  
2. Getting Started  
The PRO RX comes pre-assembled and almost ready for use, just install the  
Disk Modules, the PCI-e (PCI-express) Host Bus Extender (HBE), connect the  
cables, install the software driver and RAID Console. If you are using a Mac,  
you are good to go, by default the unit is pre-formatted for Mac OS X operation.  
For Windows, a small format procedure is needed.  
Operating Systems:  
Windows XP / Vista / 2003/ 2000 / 32 & 64-bit.  
Mac OS X 10.4 or higher.  
Apple Power Mac G5 with one available PCI-e x8 slot.  
Apple Mac Pro with one available PCI-e x8 slot.  
Windows compatible PC with one available PCI-e x8 slot.  
2.1.  
Packaging  
Please do not discard the boxes and packing materials in case you  
might need to reuse them later. Always ship the product in its original  
packaging. Improperly packaged products will be subjected to shipping  
damage, for which you will be liable for the repair.  
Internet connection (to download drivers and utilities).  
2.2.  
Check List  
1.3.  
Technical Support  
Installation and User’s Manual.  
Power Cord (North America user only).  
Set of keys.  
A 12 or 16 disk bay system enclosure.  
8, 12, or 16 Disk Modules.  
A PCI-e x8 Host Bus Extender card.  
A PCI-e x8 Extender Cable.  
Rackmount rails  
Phone  
FAX  
E-mail  
Web  
818-435-6007  
818-576-0324  
If the product requires service, please contact Dulce Systems’ Technical Support  
and obtain an RMA number. Ship the product properly packaged to:  
Dulce Systems  
Attn: RMA  
9620 Topanga Canyon Place,  
Suite E  
Chatsworth, CA 91311  
Page 8  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
Front view with bezel removed  
3. Overview  
Mute Button, Fan Alarm, Temp Alarm  
3.1.  
The Bezel  
The front bezel can be easily removed to access the Disk Modules. The bezel is  
held on by four snap pins located at each of the four corners.  
Use both hands, push from behind the left and right side of the bezel. Access  
through the rack mount handles.  
Drive Bays  
Back view  
Removable Cooling Fans  
3.2.  
Disk Modules, Indicators, Controls, Connections  
The disk enclosure has stand alone self-monitoring features. It monitors  
temperature and fan continuously. Should the temperature exceed a safe  
operating range or the fan spin below a preset minimum, the alarms will be  
triggered. A red indicator light will come on plus an audible alarm will sound.  
PCI-e Port  
Config Switches  
Audible Alarm can be muted by pressing the green Mute button. The red  
indicator remains on until the condition is corrected.  
Link Status:  
Cable Installed  
Power On  
4 or 8 Lane Mode  
Management  
Ethernet port  
Disk Module  
Power (white)  
Power Supply  
Host Bus Extender Card  
Activity (blue)  
Key Lock  
PCI-e Port  
Link Status:  
Cable Installed  
Power On  
Config  
Switches  
4 or 8 Lane Mode  
Page 10  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
4. Installation  
Please follow these few steps to install the PRO RX. This process typically takes  
about 20 minutes to complete.  
Slider  
Overview of installation:  
Rackmount installation  
Disk Module Installation  
Host Bus Extender Card Installation  
PCI-express Extender Cable Installation  
Driver Installation  
Rail mounted  
to rack.  
RAID Console Installation  
The PRO RX ship pre-configured in RAID 5 mode and pre-formatted  
for Apple Mac OS X. After the driver installation step and a reboot, the  
PRO RX icon will appear on the desktop ready for use.  
4.2.  
Disk Module Installation  
Windows operation will require a format/partition process. The PRO  
RX ship already pre-configured in RAID 5. After the driver installation,  
simply run the Windows Disk Management utility to prepare the RAID  
for Windows usage.  
Remove the front bezel. Install each marked Disk Module into the slot indicated.  
Pull the lock of the Disk Module left to open the latch. Insert into slot until latch  
begins to close, close latch to lock Disk Module into place.  
4.1.  
Rackmount Installation  
The PRO RX can be rackmounted to a standard 19” rack. 3u height space is  
required. A set of mounting rails are supplied and can be mounted to various  
rack depths.  
Mount the left and right rails to the rack, ensure sufficient 3u space is available.  
Adjust depth as required.  
Mount the left and right sliders on the PRO RX.  
Install the PRO RX carefully on the rack by aligning the sliders in the rails.  
Page 12  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
Switches 1 to 7 are preset at the  
default configuration, they should be  
left at the default settings.  
Default Setting  
4.3.  
Host Bus Extender Card  
Switch  
1
2
3
4
5
6
7
Turn off the computer and unplug the power source before proceeding with the  
Host Bus Extender (HBE) Card installation.  
On Off On Off On On Off  
Switch 8 and 9 needs to be set to match the slot  
speed of the computer. If you are unsure, the 4  
lane setting is a good place to start.  
PCI-express Lanes  
A PCI-e HBE Card supplied with your PRO RX. The HBE Card will require an  
available PCI-e slot in your computer.  
8
9
Off Off 8 Lanes  
On Off 4 Lanes  
On On 1 Lane  
4.3.2. HBE Card Installation  
The PCI-e HBE Card requires a x8 slot or larger. Computers with PCI-e slots  
less than x8 will not physically accommodate the HBE. PCI-e slots x8 or larger  
will work.  
PCI-express Host Bus Extender (HBE)  
Apple Mac Pro (Intel) and newer versions of Power Mac G5 support PCI-e, as  
well as the HP xw series workstations.  
PCI-e and PCI-x are not compatible or interchangeable with each other. A PCI-e  
card can only be installed in a PCI-e equipped computer. Some computers  
support both PCI-e and PCI-x such as the HP xw series but not Apple Macs.  
Apple Mac Pro  
and Power Mac  
Typical  
Windows PC  
4.3.1. Switch Settings  
Determine the correct switch settings. Set both the HBE and PRO RX to same  
configuration.  
The HBE Card and the PRO RX enclosure can operate at 1, 4 or 8 lane speed  
configurations. The maximum speed will be determined by the capability and  
selection of the computer’s PCI-e slot. The HBE Card and the PRO RX must be  
configured to match the speed of the computer PCI-express slot.  
PRO RX  
& HBE  
same  
settings  
Switch position  
ON OFF  
Page 14  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
4.4.3. Windows PC Connection  
4.4.  
Making the Connections  
4.4.1. PCI-e Extender Cable  
Typical Windows PC  
The PRO RX is supplied with a PCI-e Extender Cable. This cable carries 8 lanes  
of the PCI-e interface. The green tab is up in this orientation. To remove, pull  
the tab to unlock the latches and then pull the metal body to remove the  
connector.  
Green  
Tab on  
Bottom.  
Green  
Tab on  
top.  
Switches to  
left, green  
Tab on top.  
4.4.2. Mac Connection  
Mac Pro or Power Mac  
Green  
Tab on  
top.  
Green  
Tab on  
top.  
Page 16  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
4.5.2. Mac Driver Installation  
4.5.  
Driver Installation  
For the latest Mac drivers, please visit our web site and download the  
appropriate driver for your Mac.  
4.5.1. Mac Pro – Expansion Slot Utility settings  
This section applies exclusively to the Apple Mac Pro produced in  
2006 and 2007. Skip this section for Mac Pros from Early 2008 and  
later as well as all other computers.  
Download  
From:  
The Mac Pro (Intel Xeon-based) will detect changes in the PCI-e slot  
configuration, it will automatically launch the Expansion Slot Utility  
where you can make performance adjustments for the various PCI-e slots. The  
utility can be manually started also, it can be found at: Under my Mac Pro:  
/System/Library/CoreServices.  
After download, a folder named Dulce MRAID Install will be placed on your  
desktop. Open it and follow the simply steps outlined in the Install Read Me  
document.  
Ensure there is at least a x4 speed assignment for the slot where HBE Card is  
installed, making sure also that your video capture/playback card and video  
display card also get a sufficient x value.  
Example below is a good balance, it shows the RAID Controller in slot 4, a  
popular video capture card in slot 3, a eSATA adapter in slot 2, and the standard  
graphic card in slot 1.  
After driver installation, reboot the computer and the PRO RX icon will appear on  
the desktop. Your new storage is now ready to go to work.  
Pre-configured  
for Mac OS X  
You may proceed to the RAID Console section if you wish to change the  
configuration or just to learn about the RAID Console.  
Page 18  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
4.5.3. Windows XP/2000 Driver Installation  
4.6.  
RAID Console Installation  
After boot Windows will detect the RAID Controller and launch the  
“Found New Hardware Wizard.”, click Cancel to dismiss the wizard.  
4.6.1. Apple Mac RAID Console Installation  
The RAID Console is automatically installed during the driver installation  
process. No additional steps are required to install the RAID Console.  
You may proceed directly to the RAID Console Operation section.  
Download the latest driver and utility appropriate for your version of  
Windows.  
Download  
From:  
4.6.2. Windows PC RAID Console Installation  
Download the latest RAID Console utility.  
Unzip the downloaded folders and place the content on the desktop.  
Download  
From:  
Launch the Hardware Update Wizard (can be found at Start > Control  
Panel > System > Hardware < Device manager).  
Unzip and run the setup.exe to install the RAID Console utility.  
Expand Other Devices, right click RAID Controller, click Update Driver….,  
click Yes then Next.  
Select “Install from a list….(Advanced)”, click Next.  
Browse to the unzip folder and follow the instructions on screen.  
4.5.4. Windows Vista Driver Installation  
For the latest Windows Vista driver, please visit our web site and  
download the most up-today driver.  
Download  
From:  
Unzip the downloaded folder and place the content on the desktop.  
Launch Device Manager (can be found at Start > Control Panel > Systems  
and Maintenance > System).  
Expand Storage Controllers from the list, point to and right click on RAID  
Controller. Select Update Driver Software…  
Browse to the unzipped download folder to install the driver. Successful  
installation will show (SCSIPORT) SATA RAID Host Adapter.  
Page 20  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
4.7.  
Built-in Ethernet Configuration  
5. RAID Console Operations  
5.1.  
Start RAID Console GUI  
The PRO RX has a built-in Ethernet Port. In addition to managing the RAID  
Console at the host computer, this allows the PRO RX to be managed via any  
computer on the network.  
The RAID Console is where all of the management and maintenance of the  
storage unit is accomplished. After the installation process, the RAID Console is  
executed from your computer’s Web Browser.  
By default, the PRO RX uses DHCP to acquire and IP Address, you may also  
hardcode the IP address.  
5.1.1. Start Apple Mac RAID Console GUI  
Double click on the Dulce RAID Console icon in the Dulce MRAID Install  
folder to launch the RAID Console. For quicker access, you may move  
the Dulce RAID Console icon to the dock.  
Use RAID Console from the host computer to configure the Built-in Ethernet Port.  
The NetherNet Config page is located at System Control > EtherNet Config.  
A Web Browser will open and the RAID Console starts  
Default login name is: admin  
Default password is: 0000 (four zeros)  
Welcome screen of RAID Console after successful login:  
4.8.  
E-mail notification  
Setting up an e-mail event notification is easy using the built-in SMTP mail  
configuration option.  
For the latest up-to-day procedure, please check the Tech Notes section of the  
Dulce support web site:  
Page 22  
Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
5.1.2. Start Windows PC RAID Console GUI  
Welcome screen of RAID Console after successful login:  
Start the RAID Console from Start > All Programs > Areca Technology  
> ArcHttpSrvGUI > Areca HTTP Proxy Server GUI.  
The ARCHTTP service will start  
Double click on the Controller #01 to start the RAID Console  
Default login name is: admin  
Default password is: 0000 (four zeros)  
5.1.3. Built-in Ethernet  
If the PRO RX’s Ethernet port is connected to the network, and you know the IP  
address of the PRO RX, you can use any computer on the network via any web  
browser to connect to the RAID Console and manage the PRO RX.  
You can discover the PRO RX IP address by using the local computer that is  
connected to the PRO RX, launch the appropriate RAID Console. The Ethernet  
Configuration page is at System Controls > EtherNet Config.  
Page 24  
Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
5.2.2. Create a RAID Set  
5.2.  
Change RAID Mode – Deleting / Creating  
This procedure will erase all data on the PRO RX.  
No need to wait for hours of format, simply select the No Init option in the  
Volume Initialization Mode field.  
Changing the RAID mode requires the current RAID Set to be deleted  
first, then create a new RAID Set with the new RAID mode.  
For Windows XP (32 bit) with larger than 2TB RAID, read next section.  
5.2.1. Delete the RAID Set  
From the RAID Console GUI. On the left side menu bar click on  
From the RAID Console GUI. On the left side menu bar click on  
RaidSet Functions > Delete Raid Set  
Select the Raid Set and check the Confirm box  
Click Submit to delete the RAID Set  
Click on Quick Function > Quick Create  
Change the Select Raid Level as desire  
Change Greater Two TB Volume Support: Set to 64bit LBA  
Windows XP (32 bit): Set to No.  
Volume Initialization Mode: Change to No Init.  
Check Confirm the Operation  
Click Submit  
No Init allows for immediate RAID Set availability. The RAID is ready for the OS  
format and partition.  
Page 26  
Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
To view and confirm the Volume settings, select Information > RaidSet Hierarchy.  
5.2.3. Create >2TB RAID Set for Windows XP (32bit):  
If RAID is larger than 2TB, configure using multiple 2TB Volumes and then use  
Windows to Span them together. This will end up with one drive letter of the full  
capacity of the RAID.  
1)  
Create the RAID Set under RaidSet Functions by selecting all of the drives.  
Create multiple Volume Sets under the VolumeSet Functions  
Select the desired Volume Raid Level  
Set the Select Volume Capacity to 2199GB  
Set Greater Two TB Volume Support to No  
Set Volume Initialization Mode to No Init (if applicable)*  
Check the Confirm the Operation box  
Click Submit  
Repeat this step until all of the space are assigned.  
2)  
In Windows Disk Management, make these volumes as Dynamic Disks and span  
them together to make one large disk. Spanning is recommend as oppose to  
striping. Striping in this configuration requires more system overhead and will  
actually reduce performance. Use Spanning.  
* By setting the Volume Initialization Mode to No Init will result in immediate  
availability of the RAID set, no need to wait for long initialization time.  
Page 28  
Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
6. Alarm Conditions / Degraded RAID Set  
There are two possible sources for alarms: one from the enclosure monitors, the  
other from the RAID Controller inside the PRO RX.  
Enclosure Alarms  
(Audible and red indicators):  
Temperature (enclosure  
detected over heating  
condition)  
Fan (enclosure cooling  
fan not operational, could  
lead to over heating)  
Mute Alarm: Enclosure audible alarm can be muted by pressing the  
green mute button above the indicators, the red indicator remains on  
until the condition is corrected.  
6.1.  
Replacing a Disk Module  
RAID Controller Alarm  
(Audible, Drive Indicators and  
RAID Console GUI indicator):  
A defective Disk Module can be easily replaced. Hot swapping is allowed without  
interruption to your workflow if the RAID is operating in one of the drive  
redundant RAID mode (1,3,5,6).  
Degraded RAID Set (one  
or more drives not  
detected or down)  
Temperature (RAID  
Controller detected over  
heating)  
In a redundant RAID mode, rebuild will start automatically after replacement of a  
defective module.  
Pull the lock left to unlock the latch.  
Pull latch forward and right to move the module out.  
Mute Alarm: RAID Controller Alarm can be muted by the RAID  
Console. Start the RAID Console GUI, go to System Controls > View  
Event / Mute Beeper.  
The Systems Event Information screen provides a log of events which triggered  
the alarm. The example below shows the RAID Set is degraded because IDE  
Channel 4 (drive 4) was removed.  
Page 30  
Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
7.1.2. Create a new partition  
Select Dulce on the left side drive list, click on Partition tab, change Volume  
Scheme to 1 Partition, change Name as desired, click on Partition on lower right.  
7. Formatting and Partitioning  
7.1.  
Apple OS X Formatting  
The PRO RX are shipped pre-configured for Mac OS X, the RAID will  
appear on the desktop after driver installation and reboot.  
Should it be necessary to re-format and partition the RAID, use the  
Apple Disk Utility.  
To start Disk Utility, move pointer to upper left corner of screen, click on Go then  
click on Utilities. Locate and launch Disk Utility.  
7.1.1. Erase an existing partition  
Select the RAID on left, click on Partition tab, select Free Space. Click on  
Partition on lower right.  
The drive will appear on the desktop after successful completion of the Partition.  
Page 32  
Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
Right click the Unallocated segment and select New Simple Volume. Enter the  
desired Volume Size, assign the desired Drive Letter or Path, check Perform a  
Quick Format at the Format Partition screen.  
7.2.  
Windows XP / Vista Formatting  
Start Disk Management (can be found at Control Panel > System and  
Maintenance > Administrative Tools > Computer Management. Under  
Storage.)  
If the RAID shows up as Unknown / Not Initialized, right click on the disk and  
Initialize it.  
If the drive is larger than 2TB, if using Vista, right click over the disk and Convert  
to GPT Disk. Windows XP 32 bit does not support larger than 2TB capacity.  
Configure with multiple capacities of 2TB or less.  
Page 34  
Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
Limited Warranty  
WHAT THE WARRANTY COVERS  
8. RAID Level Descriptions  
Although the RAID Controller supports a large variety of RAID Levels, RAID 0 or  
RAID 3 are most commonly used for video and content creation purpose.  
Dulce Systems warrants your product against any defect in material and workmanship and conforms to Dulce published  
specifications under normal use.  
WHAT THE WARRANTY DOES NOT COVER  
The warranty does not cover equipment which has been damaged due to accident, misuse, abuse, fire, flood, "Acts of  
God," or other contingencies beyond our control; use of incorrect line voltages; improper or insufficient ventilation; failure  
to follow operating instructions; or improper or unauthorized repair; improperly packaged for shipping; packaged in non-  
approved shipping container; shipping damage.  
RAID  
Level  
Description  
Striping.  
Advantage  
Disadvantage  
Ideal for  
Highest  
resolution HD,  
2K, and  
maximum  
multiple  
No disk  
The warranty is voided by removal or alteration of the product or parts identification labels.  
Highest  
performance.  
redundancy, one  
drive failure will  
lose all data.  
0
Dulce has no liability for general, consequential, incidental or special damages. These include loss of recorded data, the  
cost of recovery of lost data, lost profits and the cost of the installation or removal of any Products, the installation of  
replacement Products, and any inspection, testing, or redesign caused by any defect or by the repair or replacement of  
Products arising from a defect in any Product.  
streams.  
WHAT THE WARRANTY PERIOD IS  
Data protection  
is paramount,  
maximum disk  
failure  
protection.  
Well balanced  
for video  
requiring  
performance  
and  
redundancy.  
Well balanced  
for file server  
requiring  
Less cost efficient  
for redundancy,  
loses ½ disk  
Dulce Systems warrants your PRO RX product for 36 months and if the product is registered with Dulce within 30 days of  
purchase, we will extend the warranty for another 6 months totaling 42 months. We warrant the Duo for 36 months. The  
warranty period begins at the date of shipment to the original end user, company or organization.  
Highest  
redundancy.  
1
3
Mirroring.  
capacity.  
Our warranty applies to repaired or replaced Products for the balance of the applicable period of the original warranty or  
ninety days from the date of shipment of a repaired or replaced Product, whichever is longer.  
WHAT WE WILL DO TO CORRECT THE PROBLEM  
Efficient drive  
redundancy, 1  
drive used for  
parity.  
Striping with  
a dedicated  
parity drive.  
Loses 1 disk drive  
capacity.  
We may elect which remedy or combination of remedies to provide at our sole discretion. We shall have a reasonable  
time after determining that a defective Product exists to repair or replace a defective Product. Our replacement Product  
under its limited warranty will be manufactured from new or reconditioned parts.  
Your exclusive remedy for any defective Product is limited to the repair or replacement of the defective Product.  
We will return the repaired or replacement Product to you prepaid using the same method of shipping (ex: overnight,  
ground, 2nd day, …) as was shipped to us. If a more expedited return shipping method is required, extra charges might  
apply at our discretion.  
Efficient drive  
redundancy,  
parity distributed  
Striping the  
parity across  
all drives.  
Loses 1 disk drive  
capacity.  
5
HOW YOU CAN GET SERVICE  
performance  
and  
redundancy.  
to all drives.  
Contact our Technical Support to obtain a RMA (Return Materials Authorization) number. The model number, serial  
number, and description of the problem will be required. A valid proof of purchase might be required to further validate the  
Products warranty eligibility, the valid proof of purchase document must show the product model, serial number, purchase  
date, and supplier name. If the valid proof of purchase is not available, the original manufacturing date of the product will  
be used to determine the warranty period.  
Striping with  
two  
dedicated  
parity drives.  
Double drive  
redundancy, 2  
drives used for  
parity.  
Each drive can  
be accessed  
individually from  
operating  
Loses 2 disk drive  
capacity.  
6
Mission critical.  
No returns will be accepted without a RMA number. We reserve the right to refuse the delivery of the return.  
You shall bear all shipping, packing and insurance costs and all other costs, excluding parts and labor, necessary to  
effectuate repair or replacement under this warranty.  
All products returned to us must be shipped in the original packaging or Dulce approved packaging. If you do not have the  
original packaging, call us to request packaging. A nominal fee will be charged for the requested packaging and for  
shipment. Ship the RMA to us pre-paid.  
Just a Bunch  
of disks.  
Audio  
applications.  
JBOD  
No redundancy.  
system.  
Products that are improperly packaged for shipping; packaged in a non-approved shipping container; or incur shipping  
damages are not covered under warranty.  
Loses another  
drive capacity. (In  
addition to the  
drive(s) needed for level exposure  
the RAID level  
A drive is set  
aside as an  
online hot  
spare.  
Minimizes  
degraded RAID  
HOW STATE LAW RELATES TO WARRANTY  
RAID  
+
Spare  
Automatic  
rebuild of a  
failed drive.  
In the United States, some states do not allow exclusion or limitation of incidental or consequential damages, so the  
limitations above may not apply to you. This warranty gives you specific legal rights and you may also have other rights  
which vary from state to state.  
time.  
selected.)  
Page 36  
Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
PRO RX Installation and User’s Manual  
(Page left blank intentionally)  
9. Product Registration  
R E G I S T E R N O W  
ADDS 6 MONTHS  
Register your product within 30 days of purchase  
and extend your warranty by another 6 months.  
1 minute = 6 months  
It will take only one minute to register and you’ll get 6 months in return!  
By registering your PRO RX, the standard 36 months warranty will be extended  
for another 6 months. That’s a total of 42 months (3 years and 6 months  
warranty.) The longest warranty in the industry!  
Please visit our web site and register online.  
A valid proof of purchase might be required to further validate the Products warranty eligibility, the  
valid proof of purchase document must show the product model, serial number, purchase date,  
and supplier name. If the valid proof of purchase is not available, the original manufacturing date  
of the product will be used to determine the warranty period.  
Page 38  
Page 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRO RX Installation and User’s Manual  
Page 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Tablet Accessory 24N815 User Manual
Greenheck Fan Ventilation Hood USGF User Manual
Haier Dishwasher DW9 AFM ME User Manual
Hotpoint Ventilation Hood RGB747GER User Manual
HP Hewlett Packard Server 670632 S21 User Manual
HP Hewlett Packard Stereo System 2138A User Manual
Hustler Turf Lawn Mower Super Duty 48 User Manual
IKEA Indoor Furnishings AA 129995 2 User Manual
IKEA Microwave Oven IMH15XR User Manual
Impex Home Gym MWM 950 User Manual