HP Hewlett Packard Switch 2012i User Manual

HP StorageWorks  
2012i Modular Smart Array  
user guide  
Part number: 481598-001  
First edition: March, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Customer Self Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Product Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Subscription Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
HP Websites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
1. Before You Begin  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
System Management Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
HP StorageWorks MSA2000 Family Storage Management Utility (SMU) . . . . 12  
Command-Line Interface (CLI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
Hardware Components and LEDs  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Controller Components and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Drive Enclosure Components and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Installing and Cabling Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
Installing Enclosures Into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
Preparing the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
Rack Installation Overview and Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32  
Connecting AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
Testing the Enclosure Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
Obtaining IP Values for Your Storage System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
Ethernet Management Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
Data Host Ethernet Port  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
iSCSI Host Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
Correcting Enclosure IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
Host System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
Installing the Microsoft iSCSI Software Initiator . . . . . . . . . . . . . . . . . . . . . . . 40  
Installing the MSA2000 Family SES Driver for Microsoft Windows Hosts . . . 41  
Connecting Data Hosts to Controller Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . 41  
Connecting Remote Management Hosts  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43  
Next Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43  
4
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Configuring a System for the First Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
Setting Management Port IP Addresses Using the CLI . . . . . . . . . . . . . . . . . . . . . . 46  
Configuring Your Web Browser for SMU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49  
Logging in to SMU from a Local Management Host . . . . . . . . . . . . . . . . . . . . . . . . 50  
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50  
Configuring Controller Enclosure Host Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
Configuring Data Host Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
Configuring the Microsoft iSCSI Software Initiator . . . . . . . . . . . . . . . . . . . . . . . . . 53  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 55  
Creating Virtual Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
Mapping a Data Host to a Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
Testing the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
Logging Out of SMU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60  
Next Steps  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60  
A. Powering the System Off and On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61  
B. Regulatory Compliance and Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63  
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83  
Contents  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Guide  
Intended Audience  
This guide is intended for use by system administrators and information  
professionals who are experienced with the following:  
Direct attach storage (DAS) or storage area network (SAN) management  
Network administration  
Network installation  
Storage system installation and configuration, including installing an HP rack  
Prerequisites  
Prerequisites for installing and configuring this product include familiarity with:  
Servers and computer networks  
Fibre Channel, iSCSI, and Ethernet protocols  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Document Conventions  
Typeface  
Meaning  
Examples  
AaBbCc123  
Book title, new term, or  
emphasized word  
See the Release Notes.  
A virtual disk (vdisk) can ....  
You must be an advanced user to ....  
AaBbCc123 Directory or file name,  
value, command, or  
The default file name is store.logs.  
The default IP address is 10.0.0.1.  
Type exit.  
on-screen output  
AaBbCc123 Text you type, contrasted # set password  
with on-screen output  
Enter new password:  
AaBbCc123 Variable text you replace  
Use the format http://ip-address.  
with an actual value  
Rack Stability  
Caution – To reduce the risk of personal injury or damage to the equipment:  
Extend leveling jacks to the floor.  
Ensure that the full weight of the rack rests on the leveling jacks.  
Install stabilizing feet on the rack.  
In multiple-rack installations, secure racks together.  
Extend only one rack component at a time. Racks may become unstable if more  
than one component is extended.  
8
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
HP Technical Support  
Telephone numbers for worldwide technical support are listed on the HP support  
Collect the following information before calling:  
Technical support registration number (if applicable)  
Product serial numbers  
Product model names and numbers  
Applicable error messages  
Operating system type and revision level  
Detailed, specific questions  
For continuous quality improvement, calls may be recorded or monitored.  
Customer Self Repair  
HP customer self repair (CSR) programs allow you to repair your HP StorageWorks  
product. If a CSR part needs replacing, HP ships the part directly to you so that you  
can install it at your convenience. Some parts do not qualify for CSR. Your HP-  
authorized service provider will determine whether a repair can be accomplished by  
CSR.  
For more information about CSR, contact your local service provider. For North  
America, see the CSR website:  
Product Warranties  
For information about HP StorageWorks product warranties, see the warranty  
information website:  
About This Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Subscription Service  
HP strongly recommends that customers sign up online using the Subscriber's  
choice website: http://www.hp.com/go/e-updates.  
Subscribing to this service provides you with e-mail updates on the latest product  
enhancements, newest versions of drivers, and firmware documentation updates as  
well as instant access to numerous other product resources.  
HP Websites  
For other product information, see the following HP websites:  
Documentation Feedback  
HP welcomes your feedback.  
To make comments and suggestions about product documentation, please send a  
message to [email protected]. All submissions become the  
property of HP.  
10 HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
CHAPTER  
1
Before You Begin  
The MSA2000 Family 2012i Modular Smart Array and MSA2000 Drive Enclosure  
are high-performance storage solutions that combine outstanding performance with  
high reliability, availability, flexibility, and manageability.  
Supported configurations include a controller enclosure with or without attached  
drive enclosures. A controller enclosure can contain two controllers that interact and  
rack cabinets.  
This chapter provides information that you must know before installing and initially  
configuring your storage system:  
“System Management Software” on page 12  
“Hardware Components and LEDs” on page 13  
“Installation Checklist” on page 23  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
System Management Software  
Embedded management software includes a web-browser interface and the  
command-line interface described below.  
HP StorageWorks MSA2000 Family Storage  
Management Utility (SMU)  
SMU is the primary interface for configuring and managing the system. A web  
server resides in each controller module. SMU enables you to manage the system  
from a web browser that is properly configured and that can access a controller  
module through an Ethernet connection.  
Information about using SMU is in its online help and in the reference guide.  
Command-Line Interface (CLI)  
The embedded CLI enables you to configure and manage the system using  
individual commands or command scripts through an out-of-band RS-232 or  
Ethernet connection.  
Information about using the CLI is in the CLI reference guide.  
12  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Hardware Components and LEDs  
This section describes the main hardware components of your storage system  
enclosures.  
Controller Components and LEDs  
The controller enclosure can be connected through switches to Ethernet adapters  
(NICs) or host iSCSI ports. Table 1-1 describes the enclosure components.  
Table 1-1 Controller Enclosure Components  
Description  
Quantity  
1
iSCSI controller (I/O) module  
SAS or SATA drive module  
AC power-and-cooling module  
1-Gbps Ethernet host port  
3-Gbps, 4-lane SAS expansion port  
Ethernet port (RJ-45)  
1 or 2  
2–12 per enclosure  
2 per enclosure  
2 per controller module  
1 per controller module  
1 per controller module  
1 per controller module  
1 per controller module  
CLI port (RS-232 micro-DB9)  
Service port (RS-232 3.5-mm jack)  
1
Air-management system drive blanks or I/O blanks must fill empty slots to maintain optimum airflow through the chassis.  
Chapter 1 Before You Begin  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
           
Figure 1-1 shows the components and LEDs on the front of a controller.  
Enclosure ID  
Drive module LEDs (top to bottom) Status LEDs (top to bottom):  
UID  
Fault/UID  
Fault ID  
Heartbeat  
Online/Activity  
Drive modules are numbered by column top to bottom: 0–2, 3–5, 6–8, 9–11  
Figure 1-1 Controller (Front View)  
Table 1-2 describes the LEDs on the front of a controller.  
Table 1-2 Controller LEDs (Front)  
Operating  
State  
LED  
Color  
Description  
Enclosure ID  
Green  
On  
Shows the enclosure ID, which enables you to correlate  
an enclosure with logical views presented by  
management software. The enclosure ID for a controller  
enclosure is zero (0); the enclosure ID for an attached  
drive enclosure is nonzero.  
UID  
Blue  
On  
Identified.  
(Unit  
Identification)  
Off  
Off  
Not identified.  
Fault ID  
Amber  
No fault condition exists.  
On  
Fault condition exists. Service action is required. The  
event has been acknowledged but the problem needs  
attention.  
Heartbeat  
LED  
Green  
On  
The enclosure is powered on with at least one power and  
cooling module operating normally.  
Off  
Both power and cooling modules are off.  
14  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Table 1-3 describes the LEDs on the drive module.  
Table 1-3 Drive Module LED Combinations (Front)  
Online/Activity  
(green)  
Fault/UID  
(amber/blue)  
Description  
On  
Off  
Off  
The drive is online, but it is not currently active.  
The drive is active and operating normally.  
Blinking  
irregularly  
Off  
Amber, blinking  
regularly (1 Hz)  
Offline; the drive is not being accessed. A predictive  
failure alert has been received for this device. Further  
investigation is required.  
On  
Amber, blinking  
regularly (1 Hz)  
Online; no activity. A predictive failure alert has been  
received for this device. Further investigation is  
required.  
Blinking  
irregularly  
Amber, blinking  
regularly (1 Hz)  
The drive is active, but a predictive failure alert has been  
received for this drive. Further investigation is required.  
Off  
Amber, solid  
Blue; solid  
Blue; solid  
Offline; no activity. A critical fault condition has been  
identified for this drive.  
Off  
Offline. The drive has been selected by a management  
application.  
On or blinking  
The drive is operating normally, and it has been selected  
by a management application.  
Blinking regularly Off  
(1 Hz)  
Do not remove the drive. Removing a drive may  
terminate the current operation and cause data loss.  
The drive is rebuilding.  
Off  
Off  
Either there is no power, the drive is offline, or the drive  
is not configured.  
Chapter 1 Before You Begin  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Figure 1-2 shows the ports and switches at the back of the controller.  
Power switch  
LINK  
ACT  
LINK  
ACT  
Service  
iSCSI  
Port  
iSCSI  
Port  
0
1
DIRTY  
CLEAN  
CLI  
CLI  
CACHE  
ACTIVITY  
10/100 BASE-T  
STATUS  
LINK  
ACT  
LINK  
ACT  
Service  
iSCSI  
Port  
iSCSI  
Port  
0
1
DIRTY  
CLEAN  
CACHE  
ACTIVITY  
10/100 BASE-T  
STATUS  
Host ports  
Figure 1-2 Controller Enclosure Ports and Switches (Back View)  
Table 1-4 describes the ports and switches on the back of the controller.  
Table 1-4 Controller Ports and Switches (Back)  
Service port  
CLI port  
Ethernet management port  
Expansion port  
Location  
Port/Switch  
Description  
Power and Power switch Toggle, where:  
cooling  
module  
• – is On  
Ois Off  
Controller Host ports  
module  
1-GbE Ethernet ports used to connect to data hosts through Ethernet  
switches. Host port 0 and 1 correspond to host channel 0 and 1,  
respectively.  
Controller Expansion  
3-Gbps, 4-lane (12 Gbps total) table-routed SAS Out port used to connect  
drive enclosures.  
module  
Controller Ethernet  
module management  
port  
port  
10/100BASE-T Ethernet port used for TCP/IP-based out-of-band  
management of the RAID controller. An internal Ethernet device provides  
standard 10 Mbit/second and 100 Mbit/second full-duplex connectivity.  
Controller CLI port  
module  
Micro-DB9 port used to connect the controller enclosure to a local  
management host using RS-232 communication for out-of-band  
configuration and management.  
Controller Service port  
module  
3.5-mm jack port used by service technicians only.  
16  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Figure 1-3 shows the LEDs at the back of the controller.  
AC Power Good  
DC Voltage/Fan Fault/  
Service Required  
Host link status  
Host link activity  
Cache status  
Host activity  
Expansion port status  
LINK  
ACT  
LINK  
ACT  
Service  
iSCSI  
Port  
iSCSI  
Port  
0
1
DIRTY  
CLEAN  
CLI  
CLI  
CACHE  
ACTIVITY  
10/100 BASE-T  
STATUS  
LINK  
ACT  
LINK  
ACT  
Service  
iSCSI  
Port  
iSCSI  
Port  
0
1
DIRTY  
CLEAN  
CACHE  
ACTIVITY  
10/100 BASE-T  
STATUS  
Unit Locator  
OK  
Ethernet activity  
Ethernet link status  
OK to Remove Fault/Service Required  
Figure 1-3 Controller LEDs (Back View)  
Table 1-5 describes the LEDs on the back of the controller  
Table 1-5 Controller LEDs (Back)  
Location  
LED  
Color  
State Description  
Power and AC Power Good  
cooling  
module  
Green  
Off  
AC power is off or input voltage is below the  
minimum threshold.  
On  
AC power is on and input voltage is normal.  
DC output voltage is normal.  
Power and DC Voltage/  
Amber Off  
On  
cooling  
module  
Fan Fault/  
Service Required  
DC output voltage is out of range or a fan is  
operating below the minimum required RPM.  
Controller Host link status  
module  
Green  
Green  
Off  
The port is empty or the link is down.  
On  
The port link is up and connected.  
Controller Host link activity  
module  
Off  
The host port is not connected or the link is down.  
On  
The host link is up and active.  
Chapter 1 Before You Begin  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Table 1-5 Controller LEDs (Back) (Continued)  
Location  
LED  
Color  
State Description  
Unit Locator  
Controller  
module  
White  
Off  
Normal operation.  
Blink Physically identifies the controller module.  
Controller  
module  
OK to  
Remove  
Blue  
Off  
The controller module is not prepared for removal.  
On  
The controller module can be removed.  
Controller  
module  
Fault/Service Amber On  
Required  
A fault has been detected or a service action is  
required.  
Blink Indicates a hardware-controlled power up or a  
cache flush or restore error.  
Controller  
module  
OK  
Green  
Green  
Off  
Controller module is not OK.  
On  
Controller module is operating normally.  
Blink System is booting.  
Controller Cache status  
module  
Off  
Cache is clean (contains no unwritten data).  
On  
Cache is dirty (contains unwritten data) and  
operation is normal.  
Blink A Compact Flash flush or cache self-refresh is in  
progress. Indicates cache activity.  
Controller Host activity  
module  
Green  
Off  
The host ports have no I/O activity.  
Blink At least one host port has I/O activity.  
Controller Ethernet link status Green  
module  
Off  
The Ethernet port is not connected or the link is  
down.  
On  
The Ethernet link is up.  
Controller Ethernet activity  
module  
Green  
Green  
Off  
The Ethernet link has no I/O activity.  
Blink The Ethernet link has I/O activity.  
Controller Expansion port  
Off  
The port is empty or the link is down.  
module  
status  
On  
The port link is up and connected.  
18  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Drive Enclosure Components and LEDs  
A drive enclosure can be connected to a controller enclosure or to another drive  
enclosure to provide additional disk storage capacity. Table 1-6 describes the drive  
enclosure components.  
Table 1-6 Drive Enclosure Components  
Description  
Quantity  
1
Expansion (I/O) module  
SAS or SATA drive module  
AC power and cooling module  
3-Gbps, 4-lane SAS In port  
3-Gbps, 4-lane SAS Out port  
Service port (RS-232 micro-DB9)  
1 or 2  
2–12 per enclosure  
2 per enclosure  
1 per expansion module  
1 per expansion module  
1
Air-management system drive blanks or I/O blanks must fill empty slots to maintain optimum airflow through the chassis.  
The components and LEDs on the front of a drive enclosure are the same as on a  
controller enclosure; see Figure 1-1 and Table 1-2.  
Chapter 1 Before You Begin  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Figure 1-4 shows the ports and switches at the back of the drive enclosure.  
Power switch  
0
0
Service  
Service  
0
0
SAS In port  
Service port  
SAS Out port  
Figure 1-4 Drive Enclosure Ports and Switches (Back View)  
Table 1-7 describes the ports and switches on the back of the drive enclosure.  
Table 1-7 Drive Enclosure Ports and Switches (Back)  
Location  
Port/Switch  
Description  
Power and  
cooling module  
Power switch Toggle, where:  
• – is On  
Ois Off  
Expansion  
module  
SAS In port  
3-Gbps, 4-lane (12 Gbps total) subtractive ingress port used to  
connect to a controller enclosure.  
Expansion  
module  
SAS Out port 3-Gbps, 4-lane (12 Gbps total) table-routed egress port used to  
connect to another drive enclosure.  
Expansion  
module  
Service port  
Micro-DB9 port for manufacturing technicians.  
20  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Figure 1-5 shows the LEDs at the back of the drive enclosure.  
AC Power Good  
DC Voltage/Fan Fault/  
Service Required  
SAS In port status  
SAS Out port status  
0
0
0
Service  
0
Service  
Unit Locator  
OK  
OK to Remove Fault/Service Required  
Figure 1-5 Drive Enclosure LEDs (Back View)  
Table 1-8 describes the LEDs on the back of the drive enclosure.  
Table 1-8 Drive Enclosure LEDs (Back)  
Location  
LED  
Color  
State Description  
Power and AC Power Good  
Green  
Off  
AC power is off or input voltage is below the  
cooling  
module  
minimum threshold.  
On  
AC power is on and input voltage is normal.  
DC output voltage is normal.  
Power and DC Voltage/  
Amber Off  
On  
cooling  
module  
Fan Fault/  
Service Required  
DC output voltage is out of range or a fan is  
operating below the minimum required RPM.  
Expansion SAS In port status Green  
module  
Off  
The port is empty or the link is down.  
On  
The port link is up and connected.  
Normal operation.  
Expansion  
module  
Unit Locator  
White  
Blue  
Off  
Blink Physically identifies the expansion module.  
Off Not implemented.  
Expansion  
module  
OK to  
Remove  
Chapter 1 Before You Begin  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
             
Table 1-8 Drive Enclosure LEDs (Back) (Continued)  
Location  
LED  
Color  
State Description  
Expansion  
module  
Fault/Service Amber On  
Required  
A fault has been detected or a service action is  
required.  
Blink Indicates a hardware-controlled power up or a  
cache flush or restore error.  
Expansion  
module  
OK  
Green  
Green  
Off  
Expansion module is not OK.  
On  
Expansion module is operating normally.  
Blink System is booting.  
Expansion SAS Out port  
Off  
The port is empty or the link is down.  
module  
status  
On  
The port link is up and connected.  
22  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation Checklist  
Table 1-9 outlines the steps required to install the enclosures and initially configure  
the system. To ensure a successful installation, perform the tasks in the order they  
are presented.  
Table 1-9 Installation Checklist  
Step Installation Task  
Where to Find Procedure  
1.  
2.  
Prepare the rack for installation.  
Install the controller enclosure and optional drive  
enclosures in the rack.  
Procedure” on page 28  
3.  
4.  
Attach the ear caps.  
Connect the enclosures.  
5.  
6.  
Connect the power cords.  
“Testing the Enclosure Connections” on  
page 36  
Test the enclosure connections.  
7.  
8.  
Obtain IP values.  
“Obtaining IP Values for Your Storage  
System” on page 37  
“Host System Requirements” on page 39  
Install required host software and drivers, including:  
• HBA drivers  
• iSCSI Software Initiator  
• MSA2000 Family SES Driver  
Chapter 1 Before You Begin  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Table 1-9 Installation Checklist (Continued)  
Step Installation Task  
Where to Find Procedure  
9.  
Connect the data hosts.  
“Connecting Remote Management  
Hosts” on page 43  
10.  
11.  
Connect the management host.  
“Configuring a System for the First  
Time” on page 45  
Perform initial configuration tasks:  
• Set management port IP properties on the  
controller enclosure  
Verify that controllers and enclosures have the  
latest firmware  
• Set the date and time on the controller enclosure  
• Configure host ports on the controller enclosure  
• Configure Ethernet ports on data hosts  
• Configure iSCSI Software Initiator settings on  
data hosts  
• Edit Registry values for Ethernet adapters on data  
hosts.  
• Create virtual disks and map volumes  
• Test the configuration  
24  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER  
2
Installing and Cabling Enclosures  
This chapter describes how to install and cable enclosures in a standard 19-inch EIA  
rack cabinet. It contains the following sections:  
“Connecting Controller and Drive Enclosures” on page 32  
“Connecting AC Power” on page 35  
“Testing the Enclosure Connections” on page 36  
“Obtaining IP Values for Your Storage System” on page 37  
“Correcting Enclosure IDs” on page 38  
“Next Steps” on page 38  
Required Tools  
The installation procedures in this chapter require the following items:  
#2 Phillips screwdriver  
Standard screwdriver  
Antistatic protection devices  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Safety Precautions  
For your protection, observe the following safety precautions when setting up your  
equipment:  
Follow all cautions and instructions marked on the equipment.  
Ensure that the voltage and frequency of your power source match the voltage  
and frequency inscribed on the equipment’s electrical rating label.  
Never push objects of any kind through openings in the equipment. Dangerous  
voltages may be present. Conductive foreign objects could produce a short circuit  
that could cause fire, electric shock, or damage to your equipment.  
Note – Do not make mechanical or electrical modifications to the product. The  
vendor is not responsible for the safety or regulatory compliance of a modified  
product.  
Caution – Two people are needed to lift and move the enclosure. Use care to avoid  
injury. An enclosure with all drives installed can weigh 65 pounds (29.5 kilograms).  
Caution – Electrostatic discharge can damage sensitive components. Be sure you  
are properly grounded before touching a static-sensitive component or assembly.  
26  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing Enclosures Into a Rack  
This section describes how to install the enclosures into a standard 19-inch rack  
cabinet with a 28 to 36-inch (71.12 to 91.44-cm) depth.  
Note – Keep all hardware items in plastic bags until you are ready to use them. This  
enables you to correctly identify the screws and avoid confusion.  
Preparing the Rack  
Before installing enclosures in a rack cabinet, ensure the rack is installed according  
to its installation instructions and that the installation complies with local safety  
codes.  
1. Stabilize the rack as described in its documentation.  
2. If the rack has casters, make sure the casters are locked to prevent the rack from  
rolling.  
3. Remove or open the top front panel and the vented back panel.  
Chapter 2 Installing and Cabling Enclosures  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
       
Rack Installation Overview and Procedure  
Figure 2-1 provides a visual overview of rack installation and components and  
corresponds to the steps that follow.  
#10-32 x 5/8-in. Truss screws  
(Step 6)  
#10-32 x 5/8-in. Truss screws  
(Step 9)  
Rear bracket connected to rack  
Threaded PEMs (4)  
Side bracket  
#8-32 x 3/16-in. flathead screws  
(Step 5)  
#8-32 x 1/4-in. flathead screws  
(Step 8)  
Figure 2-1 Overview of Standard 19-Inch EIA Rackmounting Components  
28  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Use the following procedure and refer to Figure 2-1 to install each enclosure into  
the rack.  
When positioning an enclosure in the rack, do not block the air vents at the front or  
back of the enclosure.  
Caution – If you only have one person to perform the installation, remove the  
power and cooling modules and drive modules from an enclosure before  
installation, and use the optional nylon front support brackets. If possible, position  
the enclosure on top of another device or shelf in the rack to hold the enclosure as  
you attach the front brackets.  
1. Considering your system configuration and weight distribution in the rack,  
determine where you will install each enclosure in the rack.  
2. Confirm that you have cables of adequate length to connect to hosts and to power  
outlets.  
3. (Square-cut European-style racks only) Insert the cage nuts in the corresponding  
holes on the front and rear of the rack.  
4. (Optional-one person installation) Screw the front support brackets into position on  
the rack face using #10-32 x 5/8-inch screws (two per bracket).  
These brackets enable one person to easily position and support the front of the  
enclosure in the rack during installation.  
5. Attach the side brackets to each side of the enclosure using #8-32 x 3/16-inch  
flathead screws (four to eight on each side). The right and left side brackets are  
identical.  
Note – To allow adjustment of the brackets, do not tighten the screws completely  
until the enclosure is mounted in the rack.  
a. Use the alignment marks (Figure 2-2) stamped into the side brackets to position  
the brackets and screws. The alignment marks show depth in inches.  
Determine the depth you require and align the rear-most alignment mark on the  
side bracket with the rear-most threaded holes on the enclosure. Make sure that  
the alignment mark corresponding to the depth you want lines up with both the  
top and bottom holes.  
Chapter 2 Installing and Cabling Enclosures  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29  
 
Figure 2-2 Side Bracket With Alignment Marks  
b. On one side, insert the first two screws through the side bracket slots above and  
below the alignment mark into the rear-most threaded holes in the enclosure.  
For example, to mount the enclosure in a 28-inch deep rack, position the side  
bracket so that the 28-inch alignment mark is aligned with the rear-most threaded  
holes in the enclosure.  
c. Insert up to six more screws through the side bracket slots into the other threaded  
holes in the side of the enclosure.  
d. Repeat Step b and Step c to attach the other side bracket to the enclosure.  
6. Attach the rear brackets to the rear vertical posts of the rack using #10-32 x 5/8-inch  
screws (two per bracket).  
7. Lift the enclosure and slide the side brackets into the rear brackets, which are  
attached to the rear posts.  
Adjust the depth of the side brackets so that the slots nearest the ends of the side  
brackets align with the four PEM nuts in the rear brackets.  
8. Attach each side bracket to a rear bracket using #8-32 x 1/4-inch screws (four per  
bracket).  
9. Make sure that the enclosure is level and then secure the mounting ears on the front  
of the enclosure to the rack face using #10-32 x 5/8-inch screws (two per ear).  
10. Tighten the screws in the side brackets.  
11. If you removed modules from the enclosure, reinsert them.  
12. If you attached the optional front support nylon brackets to the rack face, remove  
those brackets.  
Note – When you finish installing an enclosure, you may have unused screws left  
in your rack kit; extra screws are provided in case any are misplaced.  
30  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Attaching the Ear Caps  
The plastic ear caps are snap-on parts that require some care when attaching or  
removing them. After the enclosure has been installed in the rack cabinet, attach the  
ear caps, which are located in a plastic bag included in the controller enclosure  
package.  
1. Remove the ear caps from the plastic package.  
2. As you attach each ear cap, hold it so that its indent is closest to the chassis.  
Indent  
Left ear cap  
Indent  
Right ear cap  
Figure 2-3 Ear Caps  
3. Apply gentle pressure to snap the caps onto the chassis’ ears.  
Chapter 2 Installing and Cabling Enclosures  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31  
     
Connecting Controller and Drive Enclosures  
Use the supplied SAS cables to connect a controller enclosure to up to three drive  
enclosures. Figure 2-4 and Figure 2-5 show the recommended fault-tolerant cabling  
patterns. In an enclosure, the upper module is designated A and the lower module is  
designated B.  
When connecting multiple drive enclosures, use reverse cabling to ensure the  
highest level of fault tolerance. For example, Figure 2-5 shows controller A  
connected to expansion module 1A, and the chain of connections continuing down.  
Controller B is connected to the lower module (B) of the last drive enclosure in the  
chain, with connections moving in the opposite direction.  
Fault-tolerant cabling is recommended because it enables the controllers to access  
remaining drive enclosures if any one drive enclosure fails. However, the system  
also supports non-fault-tolerant cabling using the supplied SAS cables.  
drive enclosures.  
Note – For clarity, the schematic illustrations of the controllers shown in this  
section show only relevant details such as expansion ports. For detailed illustrations  
showing all components, see “Hardware Components and LEDs” on page 13.  
Controller A  
Controller B  
1A  
In  
In  
Out  
Out  
1B  
Figure 2-4 Cabling Connections Between One Controller Enclosure and One  
Drive Enclosure  
32  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Controller A  
Controller B  
1A  
1B  
In  
In  
Out  
Out  
2A  
2B  
In  
In  
Out  
Out  
3A  
3B  
In  
In  
Out  
Out  
Figure 2-5 Fault-Tolerant Cabling Connections Between One Controller  
Enclosure and Up to Three Drive Enclosures  
Chapter 2 Installing and Cabling Enclosures  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Controller A  
Controller B  
1A  
1B  
In  
In  
Out  
Out  
2A  
2B  
In  
In  
Out  
Out  
In  
In  
Out  
Out  
3A  
3B  
Figure 2-6 Non-Fault-Tolerant Cabling Connections Between One Controller  
and Up to Three Drive Enclosures  
34  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting AC Power  
Use this procedure to connect AC power to the enclosures.  
1. Verify that both power switches are off.  
2. Using the AC power cords, for each enclosure, connect one power and cooling  
module to one power source in the rack, and the other power and cooling module to  
a separate power source in the rack.  
3. Connect the primary power cords from the rack to separate external power sources.  
Power on the system as described in the topic that follows.  
Chapter 2 Installing and Cabling Enclosures  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
     
Testing the Enclosure Connections  
Use this procedure to power on the newly installed system.  
1. Press the power switches at the back of each drive enclosure to the On (–) position.  
This ensures that the disks in the drive enclosures have enough time to completely  
spin up before being scanned by the RAID modules in the controller enclosure.  
Depending on your configuration, it can take several minutes for the system to  
While enclosures power up, their LEDs blink. After the LEDs stop blinking, if no  
LEDs on the front and back of the enclosure are amber, the power-on sequence is  
complete and no faults have been detected.  
For a description of LED behavior and status, see “Hardware Components and  
LEDs” on page 13.  
2. Press the power switches at the back of the controller enclosure to the On (–)  
position.  
If the enclosure’s power-on sequence succeeds as described in Step 1, the system is  
ready to use.  
36  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Obtaining IP Values for Your Storage System  
Use the guidelines presented in this section when requesting or assigning IP values  
for your storage system.  
Use DHCP to obtain a different IP address for each Ethernet management port (one  
each for controller A and controller B). If you do not have a DHCP server, you will  
need to obtain the IP addresses from your network administrator, and set them using  
the CLI during initial configuration (see “Setting Management Port IP Addresses  
Using the CLI” on page 46).  
To obtain the IP and gateway addresses for the Ethernet management port using  
DHCP:  
1. Look in the DCHP server’s address for the two IP addresses assigned to an “HP  
StorageWorks MSA2000 Family” storage device.  
2. Use a network management utility to discover “HP StorageWorks MSA2000  
Family” storage devices on the local LAN through SNMP.  
3. Use a pingbroadcast to try to identify the device through the host’s ARP table.  
Data Host Ethernet Port  
From your network administrator, obtain an IP address for each data host Ethernet  
port that will be used for iSCSI connectivity. You will use these IP addresses when  
you configure data host ports (see “Configuring Data Host Ethernet Ports” on  
page 52). Each Ethernet port on a data host should be assigned an IP address on a  
different subnet.  
iSCSI Host Ports  
You will need to set IP and gateway addresses for each iSCSI host port on the  
controller enclosure when you configure iSCSI Software Initiator settings (see  
“Configuring the Microsoft iSCSI Software Initiator” on page 53).  
Chapter 2 Installing and Cabling Enclosures  
Download from Www.Somanuals.com. All Manuals Search And Download.  
37  
           
iSCSI host ports should be assigned IP addresses that are on one or the other subnet  
to which data host ports are assigned. That is, one iSCSI host port on controller A  
should be on the same subnet as one of the data host ports, with the other iSCSI host  
port on the subnet as the other data host port, and likewise for controller B.  
Correcting Enclosure IDs  
When installing a system with drive enclosures attached, the enclosure IDs might  
not agree with the physical cabling order. This is because the controller might have  
been previously attached to some of the same enclosures and it attempts to preserve  
the previous enclosure IDs if possible. To correct this condition, make sure that both  
controllers are up and perform a rescan using SMU or the CLI. This will reorder the  
enclosures, but can take up to two minutes for the enclosure IDs to be corrected.  
To perform a rescan using the CLI, type the following command:  
rescan  
To rescan using SMU, as an Advanced Manage user:  
1. Select Manage > Utilities > Disk Drive Utilities > Rescan.  
2. In the Rescan For Devices panel, click Rescan.  
Next Steps  
Now you are ready to connect the data and management hosts, as described in  
Chapter 3.  
38  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER  
3
Connecting Hosts  
This chapter describes how to connect data and management hosts to controller  
enclosures. It contains the following sections:  
“Host System Requirements” on page 39  
“Connecting Data Hosts to Controller Enclosures” on page 41  
“Connecting Remote Management Hosts” on page 43  
“Next Steps” on page 43  
Host System Requirements  
Data hosts connected to MSA2000 Family 2012i Modular Smart Arrays must meet  
the following requirements:  
Systems must have two dedicated Ethernet ports available with either HBAs or  
Ethernet adapters (NIC hardware) that support iSCSI connectivity.  
For systems with iSCSI HBAs, install any HBA drivers required for your  
system as specified in the MSA QuickSpecs. QuickSpecs can be found from  
your HP MSA products page at http://www.hp.com/go/msa. Select MSA  
SAN Arrays, and then select your product. The link for QuickSpecs will be on  
the right.  
For systems using NIC hardware, you must install and configure the  
Microsoft® iSCSI Software Initiator. For more information, see “Installing the  
Microsoft iSCSI Software Initiator” on page 40.  
Depending on your system configuration, data host operating systems may  
require that multipathing is supported. If a data host uses a single cable to attach  
to the storage, then multipathing software is not required. If a data host uses  
multiple cables to attach to the storage, and fault tolerance is expected, then  
multipathing software is required.  
To obtain the MSA2000 Family MPIO DSM, go to the HP MSA products page at  
http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product,  
and go to Related products.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
®
To prevent Microsoft Windows data hosts from displaying the Found New  
Hardware Wizard when the storage system is discovered, install the MSA2000  
Family SCSI Enclosure Services driver. For more information, see “Installing the  
MSA2000 Family SES Driver for Microsoft Windows Hosts” on page 41.  
Installing the Microsoft iSCSI Software Initiator  
Note – This section applies only to Microsoft Windows hosts that use Ethernet  
adapters (NIC hardware) for iSCSI connectivity.  
Installing the Microsoft iSCSI Software Initiator enables iSCSI connectivity on  
Ethernet host ports. The software initiator must be installed in addition to standard  
Microsoft Windows network and HBA drivers.  
1. Locate and download the Microsoft iSCSI Software Initiator (Version 2.06) for your  
host system found at:  
2. Install the software initiator as directed on the download site.  
If the operating system on your data host supports MPIO, select Microsoft MPIO  
3. Complete the installation on additional data hosts.  
Note – After connecting data hosts to the storage system as described later in this  
chapter, you must configure the iSCSI Software Initiator on each host. For more  
information, see “Configuring the Microsoft iSCSI Software Initiator” on page 53.  
40  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the MSA2000 Family SES Driver for  
Microsoft Windows Hosts  
Installing the MSA2000 Family SCSI Enclosure Services (SES) driver prevents  
Microsoft Windows hosts from displaying the Found New Hardware Wizard when  
the storage system is discovered.  
1. Download the MSA2000 Family SCSI Enclosure Services (SES) driver package  
msa2000-ses-version.zipfrom http://www.hp.com/go/msa. Select MSA  
SAN arrays, select your product, and go to Related products.  
2. Extract the package contents to a temporary folder on the host.  
3. In that folder, double-click Setup.exeto install the driver.  
4. Click Finish.  
The driver is installed.  
5. Optionally, delete the extracted files and the SES driver package.  
Connecting Data Hosts to Controller Enclosures  
This section explains how to connect the controller enclosure to data hosts through  
Ethernet switches.  
The controller enclosure has four host connections, two per controller. Connect  
Ethernet cables from controller hosts ports to switch ports, and from switch ports to  
data hosts, as shown in the following figure.  
To maintain redundancy, connect each data host through the switch or switches to  
both controller A and controller B. Make sure that link speed and topology settings  
speed mismatch prevents the host from accessing the storage system.  
Note – For clarity, the schematic illustrations of the controllers shown in this  
section show only relevant details such as host ports. For detailed illustrations  
showing all components, see “Hardware Components and LEDs” on page 13.  
Chapter 3 Connecting Hosts  
Download from Www.Somanuals.com. All Manuals Search And Download.  
41  
       
Figure 3-1 shows the preferred high-availability dual-controller connection through  
two switches to two dual-port data hosts, in which each data host has two Ethernet  
ports with each port connected to a different switch.  
Switch B  
Switch A  
Controller A  
Controller B  
Figure 3-1 High-Availability Connection Through Two Switches to Two Dual-  
Port Data Hosts  
42  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting Remote Management Hosts  
The management host directly manages systems out-of-band over an Ethernet  
network. This section describes how to connect the Ethernet cables to the  
management host.  
1. Connect an Ethernet cable to the Ethernet management port on each controller.  
Note – Do not confuse Ethernet management ports with Ethernet host ports, also  
located on the rear panel of the controller enclosure. For a description of controller  
enclosure ports, see “Hardware Components and LEDs” on page 13.  
2. Connect the other end of each Ethernet cable to a network that your management  
host can access (preferably on the same subnet).  
Next Steps  
After you have connected the management host and data hosts, you are ready to  
perform first-time configuration on the storage system and data hosts as described in  
Chapter 4.  
Chapter 3 Connecting Hosts  
Download from Www.Somanuals.com. All Manuals Search And Download.  
43  
       
44  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER  
4
Configuring a System for the First Time  
This chapter includes the following topics:  
“Configuring the Microsoft iSCSI Software Initiator” on page 53  
“Editing Registry Values for Ethernet Adapters” on page 55  
“Creating Virtual Disks” on page 58  
“Mapping a Data Host to a Volume” on page 59  
“Testing the Configuration” on page 59  
“Logging Out of SMU” on page 60  
“Next Steps” on page 60  
For information about additional configuration and management tasks, including  
changing the manageuser’s password, refer to SMU’s online help or the reference  
guide.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Setting Management Port IP Addresses Using the CLI  
Note – If you used DHCP to set the IP addresses, you do not have to set them using  
the CLI as described in this section.  
Ethernet Management ports on controller module A and controller module B are  
configured with the following default values:  
Management Port IP Address: 10.0.0.2 (controller A), 10.0.0.3 (controller B)  
IP Subnet Mask: 255.255.255.0  
Gateway IP Address: 10.0.0.1  
If the default IP addresses are not compatible with your network, you must set an IP  
address for each management port using the command-line interface (CLI)  
embedded in each controller module. The CLI enables you to access the system  
using RS-232 communication and terminal emulation software.  
Use the CLI commands described in the steps below to set the IP address for the  
Ethernet management port on each controller module.  
Once new IP addresses are set, you can change them as needed using SMU.  
Note – Changing IP settings can cause management hosts to lose access to the  
storage system.  
1. Refer to the list of IP values you obtained before beginning installation (see  
“Installation Checklist” on page 23).  
46  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Your package contents include a micro-DB9-to-DB9 serial cable. If necessary, use a  
DB9-to-DB25 adapter (not included) for connecting the serial cable to a DB25  
serial port on the host computer.  
2. Start and configure a terminal emulator, such as HyperTerminal or VT-100, using  
the display settings in Table 4-1 and the connection settings in Table 4-2.  
Table 4-1 Terminal Emulator Display Settings  
Parameter  
Value  
Terminal Emulation Mode VT-100 or ANSI (for color support)  
Font  
Terminal  
None  
80  
Translations  
Columns  
Table 4-2 Terminal Emulator Connection Settings  
Parameter  
Connector  
Baud rate (bits/sec)  
Data bits  
Value  
COM1 (typically)  
115,200  
8
Parity  
None  
1
Stop bits  
Flow control  
None  
Chapter 4 Configuring a System for the First Time  
Download from Www.Somanuals.com. All Manuals Search And Download.  
47  
         
3. In the terminal emulator, connect to controller A.  
4. Press Enter to display the CLI prompt (#).  
5. At the prompt, type the following command to set the values you obtained in Step 1  
for each Ethernet management port, first for controller A and then for controller B:  
set network-parameters ip address netmask netmask gateway gateway  
controller a|b  
where:  
address is the IP address of the controller  
netmask is the subnet mask  
gateway is the IP address of the subnet router  
a|bspecifies the controller whose network parameters you are setting  
For example:  
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0  
gateway 192.168.0.1 controller a  
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0  
gateway 192.168.0.1 controller b  
6. Type the following command to verify the new IP addresses:  
show network-parameters  
Network parameters, including the IP address, subnet mask, and gateway address  
are displayed for each controller.  
7. Disconnect from the CLI and exit the emulator.  
48  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. In the host computer's command window, type the following command to verify  
Ethernet connectivity, first for controller A and then for controller B:  
ping IP-address  
If you cannot your access your system for at least three minutes after changing  
the IP address, your network might require you to restart the management  
controller using the serial CLI. When you restart a management controller,  
communication with it is temporarily lost until it successfully restarts.  
Type the following command to restart the management controller on both  
controllers:  
restart mc both  
Configuring Your Web Browser for SMU  
Before using SMU to perform remaining steps, ensure that your web browser is  
properly configured according to the following guidelines:  
Use one of the following browsers:  
Microsoft Internet Explorer 5.5 or later  
Mozilla Firefox 1.0.7 or later  
Because SMU uses popup windows to indicate the progress of user-requested  
tasks, disable any browser features or tools that block popup windows.  
For optimal performance, set your browser to use stored (cached) web pages.  
Note – Changing your browser cache setting might affect other sites you visit with  
your browser.  
To optimize display, use a color monitor and set its color quality to the highest  
setting.  
For Internet Explorer, to ensure you can navigate beyond SMU login page, set  
the local-intranet security option to medium or medium-low.  
Chapter 4 Configuring a System for the First Time  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Logging in to SMU from a Local Management Host  
To log in to SMU from a local management host:  
1. In your web browser’s address field, type the IP address of one of the controller  
enclosure’s Ethernet management ports and press Enter.  
The SMU Login page is displayed. If the Login page does not display, verify that  
you have entered the correct IP address.  
2. On the login page, type the default management user name manageand default  
password !manage.  
3. Click Log In.  
The Status Summary page is displayed.  
Updating Firmware  
After installing the hardware and powering up the enclosure for the first time, be  
sure to verify that the controllers and drive enclosures have the latest firmware.  
SMU enables you to view the software, hardware, and other version information for  
each controller and the enclosures. To view controller version information, select  
Monitor > Status > Advanced Settings > Controller Versions.To view drive  
enclosure information, select Manage > Update Software > Enclosure Firmware >  
Show Enclosures.  
For software and firmware updates, go to http://www.hp.com/go/msa. Select  
MSA SAN Arrays, select your product, and go to Support.  
Setting the Date and Time  
You can set the date and time manually or configure the system to use Network  
Time Protocol (NTP) to obtain them from a network-attached server. When NTP is  
enabled, and if an NTP server is available, the system time and date can be obtained  
from the NTP server. This allows multiple storage devices, hosts, log files, and so  
forth to be synchronized.  
50  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
NTP server time is provided in Universal Time (UT), which provides several  
options:  
If you want to synchronize the times and logs between storage devices installed  
in multiple time zones, set all the storage devices to use UT.  
If you want to use the local time for the device, set its time zone appropriately.  
If a time server can provide local time rather than UT, configure the storage  
devices to use that time server, with no further time adjustment.  
If no NTP server is present, the date and time are maintained as if NTP had not been  
enabled.  
To manually set the system date and time:  
1. Select Manage > General Config > Set Date/Time.  
2. In the Set System Date panel, select the current month, day, and year.  
3. In the Set System Time panel, type time values using a 24-hour clock (where hour 8  
represents 8 a.m. and hour 20 represents 8 p.m.) and select the proper time zone.  
4. Click Change Date/Time.  
To obtain the date and time from an NTP server:  
1. Select Manage > General Config > Set Date/Time.  
2. In the Obtain Time With NTP panel, set Network Time Protocol to Enable and  
optionally type the IP address of an NTP server.  
If no IP server address is set, the system listens for time messages sent by an NTP  
server in broadcast mode.  
3. In the Set System Time panel, select the proper time zone.  
4. Click Change Date/Time.  
You might have to refresh the page to display updated values from the NTP server.  
Chapter 4 Configuring a System for the First Time  
Download from Www.Somanuals.com. All Manuals Search And Download.  
51  
Configuring Controller Enclosure Host Ports  
To configure iSCSI host ports on the controller enclosure, complete the following  
steps:  
1. Select Manage > General Config > Host Port Configuration.  
2. In the Controller Module Host Port Configuration panels, for each host port on  
controller A and controller B, enter the following values:  
IP address. (Refer to the list of IP addresses you obtained after you installed the  
enclosures.)  
Subnet mask. Set all subnet mask fields to 255.255.255.0  
Gateway IP address. Leave this field blank (set to 0.0.0.0) for all ports.  
3. Click Update Host Port Configuration.  
The Host Port Configuration page displays again.  
Configuring Data Host Ethernet Ports  
After installing the enclosures, you should have obtained from your network  
administrator an IP address for each data host Ethernet port that will be used for  
iSCSI connectivity. Each Ethernet port on a data host should be assigned an IP  
address on a different subnet. To configure data host Ethernet ports for iSCSI  
connectivity so that hosts can communicate with the storage system, complete the  
following steps:  
1. On the host system, click Start > Control Panel > Network Connections.  
2. Select and rename each Ethernet port that will be used for iSCSI connectivity using  
a descriptive name.  
Examples: iSCSI_Port0_10.10.10.10and iSCSI_Port1_10.11.10.10  
3. Right click on the first port and select Properties.  
4. From the This Connection Uses the Following Items list, located on the General tab,  
select Internet Protocol (TCP/IP) and click Properties.  
Select Use the Following IP Address and set IP properties as follows:  
a. Enter an IP address that is on the same subnet as IP addresses used for one of the  
iSCSI host ports on controller A and one of the iSCSI host ports on controller B.  
b. Set the subnet mask for the IP address you entered.  
c. Leave the Default gateway field blank.  
52  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
5. Click OK to save these settings.  
6. Complete Step 3 through Step 5 for the second data host Ethernet port, selecting IP  
addresses on the subnet not used for the first Ethernet port.  
IP properties have been set for Ethernet ports on the data host.  
7. Complete Step 1 to Step 6 on additional data hosts.  
Configuring the Microsoft iSCSI Software Initiator  
Now that you have connected data hosts to the storage system and set IP properties  
for the controller Ethernet management port and data host Ethernet ports, you can  
configure settings in the Microsoft iSCSI Software Initiator, which you installed  
earlier on the data hosts.  
Configuring these settings on each data host includes:  
Setting IP addresses for each iSCSI host port (called a target portal) located on  
the storage system  
Logging on to iSCSI host ports on each controller module (called a target) from  
the data host to initiate connectivity between the data host and the storage system  
Note – Before completing the steps that follow, you must connect storage system  
enclosures as described in “Installing and Cabling Enclosures” on page 25. You  
must also install all software and drivers required on data hosts (see “Host System  
Requirements” on page 39), and connect hosts to the storage system as described  
earlier in this chapter (see “Connecting Hosts” on page 39).  
1. Double-click the Microsoft iSCSI Software Initiator icon located on the desktop of  
the host system.  
2. In the Target Portals area of the Discovery tab, click Add.  
3. Enter the IP address of an iSCSI host port on your storage system, leave the Port  
field set at 3260, and click Add.  
4. Repeat Step 2 and Step 3, adding IP addresses for the remaining iSCSI host ports on  
the storage system.  
IP addresses for storage system host ports (targets) are identified on the data host.  
5. On the Targets tab, verify that two targets have been configured (.a and .b).  
If two targets are not configured, one or more of the following issues may need to  
be resolved:  
Chapter 4 Configuring a System for the First Time  
Download from Www.Somanuals.com. All Manuals Search And Download.  
53  
           
Data host IP addresses may not be set correctly  
Controller enclosure host port addresses may not be set correctly on the data host  
Cables between the controller enclosure and/or switches and/or data hosts may  
not be connected correctly  
Correct the issue, return to the Targets tab and click Refresh.  
6. If two targets are configured, select the first target (controller module) and click Log  
On.  
7. On the Log On to Target dialog, set the following options:  
a. For connectivity settings to persist across system reboots, check Automatically  
Restore this Connection When the System Boots.  
b. For fault-tolerant configurations, select Enable Multi-path.  
c. Click Advanced to set connectivity settings as follows:  
i. At the Local Adapter field, select Microsoft iSCSI Initiator from the drop-  
down menu.  
ii. At the Source IP field, select the IP address for the local data Ethernet port  
that is on the same subnet as the first target portal (iSCSI host port) to which  
you want the host to connect.  
iii. At the Target Portal field, select the IP address for the iSCSI host port on the  
target (controller module) to which you are connecting.  
iv. Repeat the log on procedure (Step i through Step iii) to initiate connectivity for  
the second target portal on the selected target.  
8. To allow LUN access through all available ports during failover, change default  
multipathing settings as follows:  
a. On the Targets tab, select the target and click Details.  
b. On the Devices tab of the Target Properties dialog, select the first device and  
click Advanced.  
c. On the MPIO tab of the Device Details dialog, select Round Robin from the Load  
Balance Policy drop-down menu and click OK.  
d. Repeat Step b and Step c for all devices listed.  
9. Repeat tasks in Step 6, Step 7, and Step 8 for the second target.  
54  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
10. On the Persistent Targets tab, verify that two entries appear for each controller (.a  
and .b) for a total of four connections.  
Configuring more than one session per controller port will use additional host  
interface resources and may cause failover to function improperly.  
If two persistent targets are not configured for each controller host port, complete  
the following steps to remove and reconfigure targets:  
a. Select each entry and click Remove.  
b. Log off for each connection by selecting Targets > Details > Sessions > Log Off.  
c. Verify that IP addresses were set correctly. If not, correct IP address settings.  
d. Log on again for each target using the instructions in this section, starting at  
Step 2.  
The data host can now communicate with the controllers through iSCSI Ethernet  
host ports.  
Editing Registry Values for Ethernet Adapters  
Note – This section applies only to Microsoft Windows hosts that use Ethernet  
adapters (NIC hardware) for iSCSI connectivity.  
For the iSCSI Software Initiator to communicate efficiently with the controller  
enclosure, edit Microsoft Windows registry settings for Ethernet adapters on data  
hosts as follows.  
Caution – Use caution when editing the Windows registry. Editing the wrong entry  
or setting an incorrect value for a setting can introduce errors that cause the system  
to malfunction. Create a registry back up before following instructions in this  
section.  
Chapter 4 Configuring a System for the First Time  
Download from Www.Somanuals.com. All Manuals Search And Download.  
55  
 
Optimizing NIC Hardware TCP Settings  
To improve performance on single-threaded read and write actions, edit the TCP  
registry settings as follows.  
Note – For hosts running Windows Server 2003 SP1 or later.  
1. Start the Registry Editor.  
2. Locate and select the following registry subkey:  
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\  
Parameters\Interfaces  
The interfaces will be listed below the key using automatically generated Globally  
Unique Identifiers (GUIDs).  
Example: 064A622F-850B-4C97-96B3-0F0E99162E56  
3. Select and perform the following steps for each GUID:  
a. Check the IPAddressor DhcpIPAddressparameters to determine whether the  
interface is used for iSCSI traffic.  
If not, skip to the next GUID.  
b. If so, from the Edit menu, select New > DWORD.  
c. Rename the value to TcpAckFrequency.  
d. Assign a value of 1.  
4. Exit the Registry Editor.  
5. Restart Windows for the new settings to take effect.  
56  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optimizing iSCSI Initiator Parameters  
To optimize performance, edit the following two iSCSI initiator registry keys:  
LinkDownTime: Edit this key to increase the amount of time that the host  
allows for failover on the controller enclosure before removing the controller  
from the system.  
MaxTransferLength: (Optional) The default registry setting for maximum size  
per I/O transfer is 256 KB. This results in larger transfers being segmented into  
multiple commands. If your application requires I/O transfers larger than 256  
KB, edit this setting.  
1. Locate and select the following registry subkey:  
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Class\  
{4D36E97B-E325-11CE-BFC1-08002BE10318}  
Instances will be listed below the key using automatically generated (GUIDs).  
Example: 0000,0001  
2. Select and perform the following steps for each instance ID:  
a. Check to see whether the DriverDescparameter is set to Microsoft iSCSI  
Initiator.  
If not, skip to the next interface ID.  
b. If so, double-click to open the instance and then to open Parameters.  
c. Edit the LinkDownTimekey. The default value is 0x0f(15). Change this to  
0x30(48).  
d. (Optional) Edit the MaxTransferLengthkey value. The default value is  
0x40000(256 KB). Common values to use instead are 0x80000(512 KB),  
0x100000(1 MB), or 0x200000(2 MB).  
3. Exit the Registry Editor.  
4. Restart Windows for the new settings to take effect.  
Chapter 4 Configuring a System for the First Time  
Download from Www.Somanuals.com. All Manuals Search And Download.  
57  
Creating Virtual Disks  
Two or more disk drives can be logically combined to form a virtual disk. The  
combined storage capacity can then be partitioned into volumes. SMU provides both  
manual and automatic methods for creating virtual disks, as described in its online  
help and in the Administrators Guide.  
As an example, the following steps use the manual method to create two virtual  
disks with the following characteristics:  
RAID 5, in which parity is distributed across all disk drives in the virtual disk  
Five disk drives per virtual disk  
One spare disk drive dedicated to each virtual disk  
One volume per virtual disk, where the volume is not visible to data hosts  
To create both virtual disks:  
1. In SMU, select Manage > Virtual Disk Config > Create A Vdisk.  
2. Select Manual Virtual Disk Creation (Detail-based).  
3. Type a name for the virtual disk.  
The name is case-sensitive and can include 17 characters. Allowed characters  
include letters, numbers, hyphens, underscores, and spaces.  
4. Select RAID 5 – Parity RAID, Parity Distributed.  
5. Click Create New Virtual Disk.  
6. Select five drives of the same size and type (all SAS or all SATA).  
7. For the dedicated spare drive option, select Yes and click Continue.  
8. Select a drive to be the spare and click Continue.  
9. For the number of volumes, select 1.  
Notice that by default the volume will not be exposed to (accessible by) hosts.  
10. Click Create Virtual Disk.  
A page is displayed that shows the progress of initializing the virtual disk.  
11. Click the link to create another virtual disk.  
12. Repeat Step 2 to Step 10 to create a second virtual disk with a different name.  
58  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Mapping a Data Host to a Volume  
To enable a data host to access a volume you created, you must map the volume to  
the host. The host value, typically the IQN (iSCSI qualified name), of each host port  
connected to the system is automatically added to the system’s global host port list.  
Before mapping a data host to a volume you must identify the data host’s iSCSI  
node name (IQN) and a LUN that the host is not using.  
To map a data host to a volume:  
1. Select Manage > Volume Management > Volume Mapping > Map Hosts To Volume.  
Notice that your first virtual disk and its volume are selected, and the volume’s host  
mapping values are set to None.  
2. In the Assign Host Access Privileges panel:  
a. Select the host port IQN value that you identified before beginning.  
b. Type the LUN that you identified.  
Notice that the mapped host will have read-write access through all controller  
host ports.  
c. Click Map It.  
Testing the Configuration  
To determine that your system is ready for use, test the configuration as follows:  
1. In SMU, select Monitor > Vdisk Status and view the configuration information for  
each virtual disk.  
The virtual disk status is Critical during initialization but you can perform I/O to the  
volume.  
2. From the data host:  
a. Make the volume an operating system partition.  
b. Verify that you can access the mapped volume and the volume size shown on the  
data host matches the size shown in SMU.  
c. Verify that you can write data to the volume.  
If the above tests succeed, your system is ready for use.  
Chapter 4 Configuring a System for the First Time  
Download from Www.Somanuals.com. All Manuals Search And Download.  
59  
         
3. Once you have determined that your system is ready for use, tighten the thumb  
screws on all SAS cables.  
4. Optionally, unmount the volume and delete the test vdisks.  
Logging Out of SMU  
If you do not log out of SMU when you have finished using it, other manageusers  
cannot log in to the same controller module and your IP address stays logged in for  
30 minutes (the default auto-logout timeout setting).  
To log out of SMU:  
1. Click Log Off at the bottom of the menu.  
The Log Off page is displayed.  
2. Click Log Off.  
Next Steps  
You have completed the initial configuration tasks covered in this guide. For  
additional information on configuring your system and performing administrative  
tasks, refer to SMU’s online help or the reference guide.  
60  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
APPENDIX  
A
Powering the System Off and On  
This appendix describes how to power off and power on the system when needed.  
Powering Off the System  
The system rarely needs to be powered off. You remove power only when you plan  
to physically move the system to another location.  
Use this procedure when you need to power off the system.  
1. Stop all I/O from hosts to the system.  
2. Use SMU to shut down both controllers.  
Wait until SMU indicates that processing is complete.  
3. Press the power switches at the back of the controller enclosure to the Off (O)  
position.  
4. Press the power switches at the back of each drive enclosure to the Off (O)  
position.  
Powering On the System  
Power on any drive enclosures before powering on the controller enclosure. This  
ensures that the disks in the drive enclosures have enough time to completely spin  
up before being scanned by the RAID controllers in the controller enclosure.  
Depending on your configuration, it can take several minutes for the system to  
power up.  
Use this procedure to turn power on for all enclosures installed in a rack.  
1. Press the power switches at the back of each drive enclosure to the On (–) position.  
While enclosures power up, their LEDs blink. After the LEDs stop blinking, if no  
LEDs on the front and back of the enclosure are amber, the power-on sequence is  
complete and no faults have been detected.  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
2. Press the power switches at the back of the controller enclosure to the On (–)  
position.  
If the enclosure’s power-on sequence succeeds as described in Step 1, the system is  
ready to use.  
62  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX  
B
Regulatory Compliance and Safety  
Regulatory Compliance  
Federal Communications Commission Notice  
Part 15 of the Federal Communications Commission (FCC) Rules and Regulations  
has established Radio Frequency (RF) emission limits to provide an interference-  
free radio frequency spectrum. Many electronic devices, including computers,  
generate RF energy incidental to their intended function and are, therefore, covered  
by these rules. These rules place computers and related peripheral devices into two  
classes, A and B, depending upon their intended installation. Class A devices are  
those that may reasonably be expected to be installed in a business or commercial  
environment. Class B devices are those that may reasonably be expected to be  
installed in a residential environment (i.e., personal computers). The FCC requires  
devices in both classes to bear a label indicating the interference potential of the  
device as well as additional operating instructions for the user.  
The rating label on the device shows which class (A or B) the equipment falls into.  
Class B devices have an FCC logo or FCC ID on the label. Class A devices do not  
have an FCC logo or FCC ID on the label. Once the class of the device is  
determined, refer to the following corresponding statement.  
Class A Equipment  
This equipment has been tested and found to comply with the limits for a Class A  
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful interference when the equipment is  
operated in a commercial environment. This equipment generates, uses, and can  
radiate radio frequency energy and, if not installed and used in accordance with the  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
instructions, may cause harmful interference to radio communications. Operation of  
this equipment in a residential area is likely to cause harmful interference, in which  
case the user will be required to correct the interference at personal expense.  
Class B Equipment  
This equipment has been tested and found to comply with the limits for a Class B  
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful interference in a residential  
installation. This equipment generates, uses, and can radiate radio frequency energy  
and, if not installed and used in accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no guarantee that  
interference will not occur in a particular installation. If this equipment does cause  
harmful interference to radio or television reception, which can be determined by  
turning the equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit that is different from that to  
which the receiver is connected.  
Consult the dealer or an experienced radio or television technician for help.  
Declaration of Conformity for Products Marked  
With the FCC logo, United States only  
This device complies with Part 15 of the FCC Rules. Operation is subject to the  
following two conditions: (1) this device may not cause harmful interference, and  
(2) this device must accept any interference received, including interference that  
may cause undesired operation.  
For questions regarding your product, visit http://www.hp.com.  
For questions regarding this FCC declaration, contact us by mail or telephone:  
Hewlett-Packard Company  
P.O. Box 692000, Mailstop 510101  
Houston, Texas 77269-2000  
1-281-514-3333  
64  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
To identify this product, refer to the part, Regulatory Model Number, or product  
number found on the product.  
Modifications  
The FCC requires the user to be notified that any changes or modifications made to  
this device that are not expressly approved by Hewlett-Packard Company may void  
the user's authority to operate the equipment.  
Cables  
Connections to this device must be made with shielded cables with metallic  
RFI/EMI connector hoods in order to maintain compliance with FCC Rules and  
Regulations.  
Regulatory Compliance Identification Numbers  
For the purpose of regulatory compliance certifications and identification, your  
product has been assigned a unique Regulatory Model Number. The RMN can be  
found on the product nameplate label, along with all required approval markings  
and information. When requesting compliance information for this product, always  
refer to this RMN. The Regulatory Model Number should not be confused with the  
marketing name or model number of the product.  
Regulatory Compliance Label Location  
The Regulatory Compliance label for the 2012fc Modular Smart Array is located  
behind the left ear on the side of the chassis.  
Laser Device  
All HP systems equipped with a laser device comply with safety standards,  
including International Electrotechnical Commission (IEC) 825. With specific  
regard to the laser, the equipment complies with laser product performance  
standards set by government agencies as a Class 1 laser product. The product does  
not emit hazardous light.  
Appendix B Regulatory Compliance and Safety  
Download from Www.Somanuals.com. All Manuals Search And Download.  
65  
       
Laser Safety Warning  
Warning – To reduce the risk of exposure to hazardous radiation:  
Do not try to open the laser device enclosure. There are no user-serviceable  
components inside.  
Do not operate controls, make adjustments, or perform procedures to the laser  
device other than those specified herein.  
Allow only HP authorized service technicians to repair the laser device.  
Certification and Classification Information  
This product contains a laser internal to the fiber optic (FO) transceiver for  
connection to the Fibre Channel communications port.  
In the USA, the FO transceiver is certified as a Class 1 laser product conforming to  
the requirements contained in the Department of Health and Human Services  
(DHHS) regulation 21 CFR, Subchapter J. A label on the plastic FO transceiver  
housing indicates the certification.  
Outside the USA, the FO transceiver is certified as a Class 1 laser product  
conforming to the requirements contained in IEC 825-1:1993 and EN 60825-1:1994,  
including Amendment 11:1996 and Amendment 2:2001.  
Laser Product Label  
The optional label in Figure 4-1 or equivalent may be located on the surface of the  
HP supplied laser device.  
This optional label indicates that the product is classified as a  
CLASS 1 LASER PRODUCT. This label may appear on the laser  
device installed in your product.  
Figure 4-1 Class 1 Laser Product Label  
66  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
International Notices and Statements  
Canadian Notice (avis Canadien)  
Class A Equipment  
This Class A digital apparatus meets all requirements of the Canadian Interference-  
Causing Equipment Regulations.  
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement  
sur le matériel brouilleur du Canada.  
Class B Equipment  
This Class B digital apparatus meets all requirements of the Canadian Interference-  
Causing Equipment Regulations.  
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement  
sur le matériel brouilleur du Canada.  
European Union Notice  
Products bearing the CE marking comply with the EMC Directive (89/336/EEC)  
and the Low Voltage Directive (73/23/EEC) issued by the Commission of the  
European Community and if this product has telecommunication functionality, the  
R&TTE Directive (1999/5/EC).  
Compliance with these directives implies conformity to the following European  
Norms (in parentheses are the equivalent international standards and regulations):  
EN55022 (CISPR 22) - Electromagnetic Interference  
EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-4- 4, IEC61000-4-5,  
IEC61000-4-6, IEC61000-4-8, IEC61000-4-11) - Electromagnetic Immunity  
Power Quality:  
EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics  
EN61000-3-3 (IEC61000-3-3) - Power Line Flicker  
EN60950 (IEC60950) - Product Safety  
Appendix B Regulatory Compliance and Safety  
Download from Www.Somanuals.com. All Manuals Search And Download.  
67  
       
Also approved under UL 60950/CSA C22.2 No. 60950-00, Safety of Information  
Technology Equipment.  
BSMI Notice  
Japanese Notice  
68  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Korean Notices  
Safety  
Battery Replacement Notice  
Your computer is equipped with a lithium manganese dioxide, a vanadium  
pentoxide, or an alkaline internal battery or battery pack. There is a danger of  
explosion and risk of personal injury if the battery is incorrectly replaced or  
mistreated. Replacement is to be done by an HP authorized service provider using  
the HP spare part designated for this product. For more information about battery  
replacement or proper disposal, contact an HP authorized reseller or HP authorized  
service provider.  
Warning – Your computer contains an internal lithium manganese dioxide, a  
vanadium pentoxide, or an alkaline battery pack. There is risk of fire and burns if  
the battery pack is not properly handled. To reduce the risk of personal injury:  
Do not attempt to recharge the battery.  
Do not expose to temperatures higher than 60°C.  
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire  
or water.  
Replace only with the HP spare part designated for this product.  
Appendix B Regulatory Compliance and Safety  
Download from Www.Somanuals.com. All Manuals Search And Download.  
69  
   
Batteries, battery packs, and accumulators should not be disposed of together with the  
general household waste. To forward them to recycling or proper disposal, please use the  
public collection system or return them to HP, an authorized HP Partner, or their agents.  
For more information about battery replacement or proper disposal, contact an HP  
authorized reseller or service provider.  
Taiwan Battery Recycling Notice  
The Taiwan EPA requires dry battery manufacturing or importing firms  
in accordance with Article 15 of the Waste Disposal Act to indicate the  
recovery marks on the batteries used in sales, giveaway or promotion.  
Contact a qualified Taiwanese recycler for proper battery disposal.  
Power Cords  
The power cord set must meet the requirements for use in the country where the  
product was purchased. If the product is to be used in another country, purchase a  
power cord that is approved for use in that country.  
The power cord must be rated for the product and for the voltage and current  
marked on the product electrical ratings label. The voltage and current rating of the  
cord should be greater than the voltage and current rating marked on the product. In  
2
addition, the diameter of the wire must be a minimum of 1.00 mm or 18 AWG, and  
the length of the cord must be between 1.8 m (6 ft) and 3.6 m (12 ft). If you have  
questions about the type of power cord to use, contact an HP authorized service  
provider.  
Note – Route power cords so that they will not be walked on and cannot be pinched  
by items placed upon or against them. Pay particular attention to the plug, electrical  
outlet, and the point where the cords exit from the product.  
70  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Japanese Power Cord Notice  
Electrostatic Discharge  
To prevent damage to the system, be aware of the precautions you need to follow  
when setting up the system or handling parts. A discharge of static electricity from  
a finger or other conductor may damage system boards or other static-sensitive  
devices. This type of damage may reduce the life expectancy of the device.  
Preventing Electrostatic Damage  
To prevent electrostatic damage, observe the following precautions:  
Avoid hand contact by transporting and storing products in static-safe containers.  
Keep electrostatic-sensitive parts in their containers until they arrive at static-free  
workstations.  
Place parts on a grounded surface before removing them from their containers.  
Avoid touching pins, leads, or circuitry.  
Always be properly grounded when touching a static-sensitive component or  
assembly (see “Grounding Methods” on page 71).  
Grounding Methods  
There are several methods for grounding. Use one or more of the following methods  
when handling or installing electrostatic-sensitive parts:  
Use a wrist strap connected by a ground cord to a grounded workstation or  
computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm  
(±10 percent) resistance in the ground cords. To provide proper ground, wear the  
strap snug against the skin.  
Use heel straps, toe straps, or boot straps at standing workstations. Wear the  
straps on both feet when standing on conductive floors or dissipating floor mats.  
Use conductive field service tools.  
Use a portable field service kit with a folding static-dissipating work mat.  
If you do not have any of the suggested equipment for proper grounding, have an  
HP authorized reseller install the part.  
Appendix B Regulatory Compliance and Safety  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                       
Note – For more information on static electricity, or assistance with product  
installation, contact your HP authorized reseller.  
Waste Electrical and Electronic Equipment Directive  
Czechoslovakian Notice  
Danish Notice  
Bortskaffelse af affald fra husstande i den Europæiske Union  
Hvis produktet eller dets emballage er forsynet med dette symbol, angiver det,  
at produktet ikke må bortskaffes med andet almindeligt husholdningsaffald.  
I stedet er det dit ansvar at bortskaffe kasseret udstyr ved at aflevere det på den  
kommunale genbrugsstation, der forestår genvinding af kasseret elektrisk og  
elektronisk udstyr. Den centrale modtagelse og genvinding af kasseret udstyr  
i forbindelse med bortskaffelsen bidrager til bevarelse af naturlige ressourcer  
og sikrer, at udstyret genvindes på en måde, der beskytter både mennesker og miljø.  
Yderligere oplysninger om, hvor du kan aflevere kasseret udstyr til genvinding, kan du få hos  
kommunen, den lokale genbrugsstation eller i den butik, hvor du købte produktet.  
72  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dutch Notice  
Verwijdering van afgedankte apparatuur door privé-gebruikers in de Europese Unie  
Dit symbool op het product of de verpakking geeft aan dat dit product niet  
mag worden gedeponeerd bij het normale huishoudelijke afval. U bent zelf  
verantwoordelijk voor het inleveren van uw afgedankte apparatuur bij een  
inzamelingspunt voor het recyclen van oude elektrische en elektronische  
apparatuur. Door uw oude apparatuur apart aan te bieden en te recyclen,  
kunnen natuurlijke bronnen worden behouden en kan het materiaal worden  
hergebruikt op een manier waarmee de volksgezondheid en het milieu worden beschermd.  
Neem contact op met uw gemeente, het afvalinzamelingsbedrijf of de winkel waar u het  
product hebt gekocht voor meer informatie over inzamelingspunten waar u oude apparatuur  
kunt aanbieden voor recycling.  
English Notice  
Disposal of waste equipment by users in private household in the European Union  
This symbol on the product or on its packaging indicates that this product must not be  
disposed of with your other household waste. Instead, it is your responsibility to  
dispose of your waste equipment by handing it over to a designated collection point  
for recycling of waste electrical and electronic equipment. The separate collection  
and recycling of your waste equipment at the time of disposal will help to conserve  
natural resources and ensure that it is recycled in a manner that protects human  
health and the environment. For more information about where you can drop off your  
waste equipment for recycling, please contact your local city office, your household waste disposal  
service, or the shop where you purchased the product.  
Appendix B Regulatory Compliance and Safety  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Estonian Notice  
Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus  
See tootel või selle pakendil olev sümbol näitab, et kõnealust toodet ei tohi  
koos teiste majapidamisjäätmetega kõrvaldada. Teie kohus on oma  
seadmete jäätmed kõrvaldada, viies need elektri- ja elektroonikaseadmete  
jäätmete ringlussevõtmiseks selleks ettenähtud kogumispunkti. Seadmete  
jäätmete eraldi kogumine ja ringlussevõtmine kõrvaldamise ajal aitab kaitsta  
loodusvarasid ning tagada, et ringlussevõtmine toimub viisil, mis kaitseb inimeste tervist  
ning keskkonda. Lisateabe saamiseks selle kohta, kuhu oma seadmete jäätmed  
ringlussevõtmiseks viia, võtke palun ühendust oma kohaliku linnakantselei,  
majapidamisjäätmete kõrvaldamise teenistuse või kauplusega, kust Te toote ostsite.  
Finnish Notice  
Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella  
Jos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa hävittää  
kotitalousjätteiden mukana. Tällöin hävitettävä laite on toimitettava sähkölaitteid  
ja elektronisten laitteiden kierrätyspisteeseen. Hävitettävien laitteiden erillinen  
käsittely ja kierrätys auttavat säästämään luonnonvaroja ja varmistamaan, että  
laite kierrätetään tavalla, joka estää terveyshaitat ja suojelee luontoa. Lisätietoja  
paikoista, joihin hävitettävät laitteet voi toimittaa kierrätettäväksi, saa ottamalla  
yhteyttä jätehuoltoon tai liikkeeseen, josta tuote on ostettu.  
74  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
French Notice  
Élimination des appareils mis au rebut par les ménages dans l'Union européenne  
Le symbole apposé sur ce produit ou sur son emballage indique que ce produit  
ne doit pas être jeté avec les déchets ménagers ordinaires. Il est de votre  
responsabilité de mettre au rebut vos appareils en les déposant dans les centres  
de collecte publique désignés pour le recyclage des équipements électriques  
et électroniques. La collecte et le recyclage de vos appareils mis au rebut  
indépendamment du reste des déchets contribue à la préservation des ressources  
naturelles et garantit que ces appareils seront recyclés dans le respect de la santé humaine  
et de l'environnement. Pour obtenir plus d'informations sur les centres de collecte et de  
recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, l  
es services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté  
ce produit.  
German Notice  
Entsorgung von Altgeräten aus privaten Haushalten in der EU  
Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin, dass  
das Produkt nicht über den normalen Hausmüll entsorgt werden darf. Benutzer  
sind verpflichtet, die Altgeräte an einer Rücknahmestelle für Elektro- und  
Elektronik-Altgeräte abzugeben. Die getrennte Sammlung und ordnungsgemäß  
Entsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei  
und garantiert eine Wiederverwertung, die die Gesundheit des Menschen und  
die Umwelt schützt. Informationen dazu, wo Sie Rücknahmestellen für Ihre Altgeräte finden  
erhalten Sie bei Ihrer Stadtverwaltung, den örtlichen Müllentsorgungsbetrieben oder im  
Geschäft, in dem Sie das Gerät erworben haben.  
Appendix B Regulatory Compliance and Safety  
Download from Www.Somanuals.com. All Manuals Search And Download.  
75  
Greek Notice  
.
,
.
.
,
,
.
Hungarian Notice  
szülékek magánháztartásban történ selejtezése az Európai Unió területén  
A készüléken, illetve a szülék csomagolásán láthaazonos szimbólum annak  
jelzésére szolgál, hogy a szülék a selejtezés során az egyéb háztartási  
hulladéktól eltér módon kezelend . A vásárló a hulladékká vált készüléket köteles  
a kijelölt gy jt helyre szállítani az elektromos és elektronikai készülékek  
újrahasznosítása céljából. A hulladékká vált készülékek selejtezéskori begy jtése  
és újrahasznosítása hozzájárul a természeti er források meg rzéséhez, valamint biztosítja  
a selejtezett termékek környezetre és emberi egészségre nézve biztonságos feldolgozását.  
A begy jtés pontos helyér l b vebb tájékoztast a lakhelye szerint illetékes önkormányzattól,  
az illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat.  
76  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Italian Notice  
Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea  
Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto  
non può essere smaltito insieme ai rifiuti domestici. È responsabilità dell'utente  
smaltire le apparecchiature consegnandole presso un punto di raccolta designato  
al riciclo e allo smaltimento di apparecchiature elettriche ed elettroniche. La raccolta  
differenziata e il corretto riciclo delle apparecchiature da smaltire permette di  
proteggere la salute degli individui e l'ecosistema. Per ulteriori informazioni relative  
ai punti di raccolta delle apparecchiature, contattare l'ente locale per lo smaltimento dei rifiuti,  
oppure il negozio presso il quale è stato acquistato il prodotto.  
Latvian Notice  
Nolietotu iek rtu izn cin šanas noteikumi lietot jiem Eiropas Savien bas  
priv taj s m jsaimniec b s  
Š ds simbols uz izstr d juma vai uz t iesai ojuma nor da, ka šo  
izstr d jumu nedr kst izmest kop ar citiem sadz ves atkritumiem. J s  
atbildat par to, lai nolietot s iek rtas tiktu nodotas speci li iek rtotos  
punktos, kas paredz ti izmantoto elektrisko un elektronisko iek rtu  
sav kšanai otrreiz jai p rstr dei. Atseviš a nolietoto iek rtu sav kšana un  
otrreiz j p rstr de pal dz s saglab t dabas resursus un garant s, ka š s iek rtas tiks  
otrreiz ji p rstr d tas t d veid , lai pasarg tu vidi un cilv ku vesel bu. Lai uzzin tu, kur  
nolietot s iek rtas var izmest otrreiz jai p rstr dei, j v ršas savas dz ves vietas  
pašvald b , sadz ves atkritumu sav kšanas dienest vai veikal , kur izstr d jums tika  
nopirkts.  
Appendix B Regulatory Compliance and Safety  
Download from Www.Somanuals.com. All Manuals Search And Download.  
77  
Lihuanian Notice  
Nolietotu iek rtu izn cin šanas noteikumi lietot jiem Eiropas Savien bas  
priv taj s m jsaimniec b s  
Š ds simbols uz izstr d juma vai uz t iesai ojuma nor da, ka šo  
izstr d jumu nedr kst izmest kop ar citiem sadz ves atkritumiem. J s  
atbildat par to, lai nolietot s iek rtas tiktu nodotas speci li iek rtotos  
punktos, kas paredz ti izmantoto elektrisko un elektronisko iek rtu  
sav kšanai otrreiz jai p rstr dei. Atseviš a nolietoto iek rtu sav kšana un  
otrreiz j p rstr de pal dz s saglab t dabas resursus un garant s, ka š s iek rtas tiks  
otrreiz ji p rstr d tas t d veid , lai pasarg tu vidi un cilv ku vesel bu. Lai uzzin tu, kur  
nolietot s iek rtas var izmest otrreiz jai p rstr dei, j v ršas savas dz ves vietas  
pašvald b , sadz ves atkritumu sav kšanas dienest vai veikal , kur izstr d jums tika  
nopirkts.  
Polish Notice  
Pozbywanie si zu ytego sprz tu przez u ytkowników w prywatnych gospodarstwach  
domowych w Unii Europejskiej  
Ten symbol na produkcie lub jego opakowaniu oznacza, e produktu nie wolno  
wyrzuca do zwykłych pojemników na mieci. Obowi zkiem u ytkownika jest  
przekazanie zu ytego sprz tu do wyznaczonego punktu zbiórki w celu recyklingu  
odpadów powstałych ze sprz tu elektrycznego i elektronicznego. Osobna zbiórka  
oraz recykling zu ytego sprz tu pomog w ochronie zasobów naturalnych  
i zapewni ponowne wprowadzenie go do obiegu w sposób chroni cy zdrowie człowieka  
i rodowisko. Aby uzyska wi cej informacji o tym, gdzie mo na przekaza zu yty sprz t do  
recyklingu, nale y si skontaktowa z urz dem miasta, zaadem gospodarki odpadami lub  
sklepem, w którym zakupiono produkt.  
78  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Portuguese Notice  
Descarte de Lixo Elétrico na Comunidade Européia  
Este símbolo encontrado no produto ou na embalagem indica que o produto não  
deve ser descartado no lixo doméstico comum. É responsabilidade do cliente  
descartar o material usado (lixo elétrico), encaminhando-o para um ponto de  
coleta para reciclagem. A coleta e a reciclagem seletivas desse tipo de lixo  
ajudarão a conservar as reservas naturais; sendo assim, a reciclagem será feita  
de uma forma segura, protegendo o ambiente e a saúde das pessoas. Para obter  
mais informações sobre locais que reciclam esse tipo de material, entre em contato com  
o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que  
o produto foi adquirido.  
Slovakian Notice  
Appendix B Regulatory Compliance and Safety  
Download from Www.Somanuals.com. All Manuals Search And Download.  
79  
Slovenian Notice  
Spanish Notice  
Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios  
particulares en la Unión Europea  
Este símbolo en el producto o en su envase indica que no debe eliminarse junto  
con los desperdicios generales de la casa. Es responsabilidad del usuario eliminar  
los residuos de este tipo depositándolos en un "punto limpio" para el reciclado  
de residuos eléctricos y electrónicos. La recogida y el reciclado selectivos de  
los residuos de aparatos eléctricos en el momento de su eliminación contribuirá  
a conservar los recursos naturales y a garantizar el reciclado de estos residuos  
de forma que se proteja el medio ambiente y la salud. Para obtener más información sobre  
los puntos de recogida de residuos eléctricos y electrónicos para reciclado, póngase en  
contacto con su ayuntamiento, con el servicio de eliminación de residuos domésticos o  
con el establecimiento en el que adquirió el producto.  
80  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Swedish Notice  
Bortskaffande av avfallsprodukter från användare i privathushåll inom  
Europeiska Unionen  
Om den här symbolen visas på produkten eller förpackningen betyder det att  
produkten inte får slängas på samma ställe som hushållssopor. I stället är det  
ditt ansvar att bortskaffa avfallet genom att överlämna det till ett uppsamlingsställe  
avsett för återvinning av avfall från elektriska och elektroniska produkter. Separat  
insamling och återvinning av avfallet hjälper till att spara på våra naturresurser  
och gör att avfallet återvinns på ett sätt som skyddar människors hälsa och miljön.  
Kontakta ditt lokala kommunkontor, din närmsta återvinningsstation för hushållsavfall eller  
affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall  
för återvinning.  
Appendix B Regulatory Compliance and Safety  
Download from Www.Somanuals.com. All Manuals Search And Download.  
81  
82  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
to remote management hosts, 43  
using reverse cabling, 32  
controller enclosures  
A
accessing  
SMU, 50  
the CLI, 46  
components, 13  
configuring host ports, 52  
connecting to data hosts, 41  
connecting to multiple drive enclosures, 32  
connecting to remote management hosts, 43  
accumulators, 70  
Avis Canadien, regulatory compliance  
notice, 67  
LEDs  
B
batteries  
cache status, 18  
Ethernet activity, 18  
Ethernet link status, 18  
expansion port status, 18  
Fault/Service Required, 18  
host activity, 18  
host link speed, 17  
host link status, 17  
OK to Remove, 18  
Unit Locator, 18  
location, 16  
recycling or disposal, 70  
replacement  
notice, 69  
Taiwan EPA recycling and disposal, 70  
boot straps, using, 71  
BSMI, regulatory compliance notice, 68  
C
cables  
FCC compliance statement, 65  
shielded, 65  
ports  
Ethernet, 16  
expansion, 16  
host, 16  
certification and classification information, laser, 66  
Class A equipment, Canadian compliance statement, 67  
Class B equipment, Canadian compliance statement, 67  
CLI, See command-line interface  
service, 16  
cord. See power cord  
command-line interface  
about, 12  
accessing, 46  
additional documentation, 60  
configuring  
connecting to controller enclosures  
mapping to volumes, 59  
preparing iSCSI ports, 40, 52  
system requirements, 39  
switch attach configurations, 41  
connecting  
AC power, 35  
controller and drive enclosures, 32  
controller enclosures to data hosts, 41  
serial cable to set IP address, 46  
date and time, setting, 50  
declaration of conformity, 64  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
disposal  
waste equipment for EU private households, 73  
disposal, battery, 70  
disposal, Taiwan EPA battery, 70  
drive enclosures  
Class A Equipment, compliance notice, 63  
Class B Equipment, compliance notice, 64  
declaration of conformity, 64  
modifications, 65  
notice, 63  
floor mats, dissipating, 71  
components, 19  
connecting to controller enclosures, 32  
drive modules  
LEDs, 15  
ground strap specifications, 71  
grounding  
methods, 71  
location, 14  
suggested equipment for, 71  
E
ear caps, attaching, 31  
enclosures  
heel straps, using, 71  
help, obtaining, 10  
hosts, See data hosts  
attaching ear caps, 31  
cabling configurations, 32  
installing in a rack, 28  
powering off, 61  
HP  
address for  
powering on, 61  
ESD (electrostatic discharge)  
prevention measures, 71  
storing products, 71  
FCC questions, 64  
telephone number  
FCC questions, 64  
transporting products, 71  
European Union, regulatory compliance  
notice, 67  
indicators, See LEDs  
expansion modules  
LEDs  
installing enclosures  
checklist, 23  
Fault/Service Required, 22  
FRU OK, 22  
in a rack, 28  
safety precautions, 26  
OK to Remove, 21  
SAS In port status, 21  
SAS Out port status, 22  
Unit Locator, 21  
location, 20  
iSCSI Software Initiator, 40  
SES driver, 41  
IP addresses  
setting using the CLI, 46  
ports  
SAS In, 20  
SAS Out, 20  
service, 20  
setting using DHCP, 37  
iSCSI Software Initiator, installing on data hosts, 40  
J
Japan  
F
failover, 11  
regulatory compliance notice, 68  
fault tolerance, 32, 33  
FCC (Federal Communications Commission)  
84  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
expansion, 16  
host, 16  
SAS In, 20  
SAS Out, 20  
service, 20  
K
L
label, laser, 66  
power  
laser  
connecting AC, 35  
switches, 16  
LEDs  
international certification and classification  
information, 66  
product label, 66  
radiation, warning, 66  
regulatory compliance notice, 65  
AC Power Good, 17, 21  
power switches, 16, 20  
LEDs  
AC Power Good, 17, 21  
cache status, 18  
DC Voltage/Fan Fault/Service Required, 17, 21  
drive modules, 15  
compliance notice, 70  
current rating, 70  
replacement, 70  
set, 70  
Enclosure ID, 14  
Ethernet activity, 18  
Ethernet link status, 18  
expansion port status, 18  
fault ID, 14  
voltage rating, 70  
Fault/Service Required, 18, 22  
FRU OK, 22  
heartbeat, 14  
host activity, 18  
installing enclosures in, 28  
preparing, 27  
host link speed, 17  
host link status, 17  
OK to Remove, 18, 21  
SAS In port status, 21  
SAS Out port status, 22  
status, 14  
recycling, battery, 70  
recycling, Taiwan EPA battery, 70  
regulatory compliance  
information number, 65  
notices  
BSMI, 68  
Canada, 67  
Class A, 63  
Class B, 64  
Unit identification (UID), 14  
Unit Locator, 18, 21  
lithium battery, 69  
European Union, 67  
HP series number, 65  
Japan, 68  
Korean, 69  
lasers, 65  
M
managing storage systems  
using SMU, 12  
using the CLI, 12  
modifications, 65  
shielded cables, 65  
remote management, 43  
replacing a power cord, 70  
reverse cabling, 32  
P
parts  
proper handling, 71  
storing, 71  
transporting, 71  
RFI/EMI connector hoods, 65  
ports  
Index  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S
safety precautions, 26  
creating, 58  
viewing status, 59  
voltage compliance rating, 70  
SMU  
additional documentation, 60  
configuring, 49  
creating virtual disks, 58  
logging in, 50  
mapping data hosts, 59  
verifying, 59  
logging out, 60  
warnings  
lasers, radiation, 66  
static-dissipating work mat, 71  
waste equipment disposal for EU private households, 73  
web-browser configuration, 49  
websites  
static-safe containers  
storing products, 71  
transporting products, 71  
status LEDs, 14  
HP storage, 10  
HP Subscriber’s choice, 10  
Storage Management Utility, See SMU  
work mat, static-dissipating, 71  
storage system  
powering off, 61  
powering on, 61  
specifications, 71  
using, 71  
testing configuration, 59  
storage website, 10  
straps, ground  
boot, 71  
heel, 71  
toe, 71  
Subscriber’s choice website, 10  
Subscriber’s choice, HP, 10  
switch attach configurations, 41  
T
telephone numbers  
FCC questions, 64  
terminal emulator  
connection settings, 47  
display settings, 47  
toe straps, using, 71  
tools required for installation, 25  
tools, conductive type, 71  
U
UID LED, 14  
Unit identification (UID) LED, 14  
86  
HP StorageWorks 2012i Modular Smart Array user guide • March 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Great Dane Lawn Mower GDSZ48 14KA User Manual
Grizzly Iron H6138 User Manual
Hans Grohe Plumbing Product 04082XX0 User Manual
Honeywell Fan HS 2007 Series User Manual
Hotpoint Refrigerator HL161I User Manual
HP Hewlett Packard Photo Printer Pro B8850 User Manual
HTC Cell Phone DVB H User Manual
Husqvarna Chainsaw 115 13 81 95 User Manual
Husqvarna Trimmer 227L LD User Manual
Image Home Gym IMBE53901 User Manual