QuickSpecs  
Overview  
HP Basic Power Distribution Units  
HP Basic PDUs are designed for simple installation, reliability and cost effective power distribution. They come in a variety of form  
factors and outlet configurations to meet the needs of today's high-density data center rack environments. With effective power  
distribution supporting from 12 to 42 outlet receptacles and power levels ranging from 1.9 kVA through 19.9 kVA, HP has the Basic  
single or 3-phase PDU for any application.  
The low profile single piece design on these PDU's provides ease of access to rear devices for maintenance consideration and provides  
multiple mounting options. They are designed for HP racks but will also work in a large variety of third party racks as well. They can be  
installed on either side of the rack with outlets facing the back of the rack for easy access and improved clearance. Also for higher  
power density they can be installed side by side on both sides of the rack with the outlets facing in towards the center of the rack.  
HP Basic PDUs are available in 1U/0U and vertical form factors in single and 3-phase models and are back by HP's limited 3-year  
warranty.  
Basic PDU, 1U/0U Models (H5M54A shown)  
Basic PDU, Half Height Models (H5M55A shown)  
Basic PDU, Mid Height Models (H5M62A/H5M70A shown)  
Basic PDU, Full Height Models (H5M67A/H5M73A shown)  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Models  
HP Basic Power Distribution Units  
HP Basic PDU Models  
HP 1.9kVA 120 Volt 12 Outlet NA/JP Basic Power Distribution Unit  
HP 2.8kVA 120 Volt 18 Outlet NA/JP Basic Power Distribution Unit  
H5M54A  
H5M55A  
H5M56A  
H5M57A  
H5M58A  
H5M59A  
H5M60A  
H5M61A  
H5M62A  
H5M63A  
HP 3.6kVA 200-240 Volt 12 Outlet WW Basic Power Distribution Unit  
HP 3.6kVA 200-240 Volt 20 Outlet WW Basic Power Distribution Unit  
HP 4.9kVA 208 Volt 20 Outlet NA/JP Basic Power Distribution Unit  
HP 4.9kVA 208 Volt 30 Outlet NA/JP Basic Power Distribution Unit  
HP 8.3kVA 208 Volt 36 Outlet NA/JP Basic Power Distribution Unit  
HP 8.6kVA 208 Volt Three Phase 18 Outlet NA/JP Basic Power Distribution Unit  
HP 8.6kVA 208 Volt Three Phase 30 Outlet NA/JP Basic Power Distribution Unit  
HP 5.7kVA 208 Volt Three Phase 27 Outlet NA/JP Dual Voltage Basic Power Distribution  
Unit  
HP 8.6kVA 208 Volt Three Phase 30 Outlet NA/JP Dual Voltage Basic Power Distribution  
Unit  
H5M64A  
HP 11kVA 400 Volt Three Phase 42 Outlet NA Basic Power Distribution Unit  
HP Hardwired 200-240 Volt 36 Outlet WW Basic Power Distribution Unit  
HP 13.2kVA 480 Volt Three Phase 15 Outlet NA Basic Power Distribution Unit  
HP 19.9kVA 480 Volt Three Phase 30 Outlet NA Basic Power Distribution Unit  
H5M67A  
H5M75A  
H3X07A  
H3X08A  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Standard Features  
Features List  
HP Basic Power Distribution Units  
One piece rack mount PDUs  
Industry standard button and keyhole mounting  
Easily accessible outlet receptacles and improved cable management  
Models range from 1.9kVA to 19.9kVA  
Key Features  
Ultra-thin design does not interfere with rear maintenance  
1U/0U and vertical form factors with flexible mounting options  
Easy drop in installation  
Multiple models for  
flexible installation  
The HP Basic PDUs is available in four form factors for a variety of racks and environments. All HP Basic  
PDUs can be mounted to stay completely out of the critical rear maintenance path needed to service IT  
equipment in the rack. All vertical models use industry standard button and keyhole mounting for simple  
drop in installation in HP 11000 G2 and Intelligent Series racks and many third party racks.  
1U/0U Basic PDUs  
Mounts in 1U of space in any EIA standard rack these PDUs can also mount in the side of an HP rack for 0U  
mounting. Available in either a low voltage model with twelve NEMA 5-20 receptacles or a high voltage  
model with twelve IEC C13 outlets.  
Vertical Basic PDUs  
A variety of sizes meet the needs of many environments  
Mounts vertically on either side in the rear of the rack using industry standard button and keyhole  
mounting.  
Standard mounting faces the outlet towards the rear of the rack. This configuration fully prevents  
interference in the maintenance zone between rear RETMA rails.  
Using the optional configuration of facing the outlets into the rack, multiple PDUs can be mounted  
on one side of the rack for higher power density.*  
NOTE: Facing the outlets into the rack will interfere with the lower few rack U spaces of the rear  
maintenance zone due to breakers on the PDUs.  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Standard Features  
HP Basic Power Distribution Units  
Vertical PDU Form Factors  
Half Height Basic PDU  
Designed to fit in 22U and taller racks  
Available in low voltage and three phase models with up to 20 outlets.  
Up to 4 Half Height PDUs can be mounted in one side of a 42U or 47U rack using the optional  
inward facing configuration.  
Mid Height Basic PDUs  
Designed to fit in 36U and taller racks  
Available in high voltage and three phase models with a combination of C13 and C19 outlets  
for up to 36 outlets.  
New Three Phase Dual Voltage models provide three NEMA 5-20 convenience outlets for low  
voltage equipment in a high voltage rack.  
Full Height Basic PDUs  
Designed for 42U and taller racks.  
Available in three phase only with 36 x C13 and 6x C19 for a total of 42 outlets.  
480V Basic PDUs  
480V three phase 5 wire input provides 277V single phase output.  
Unique outlets prevent connection of non-277V compatible equipment.  
Available in a 15 outlet Half Height and a 30 outlet Full Height model.  
NOTE: When mounted in the standard rear facing configuration only 1 Mid or Full Height Basic PDU can be  
mounted per side of the rack. Up to 2 Half Height Basic PDUs can be mounted per side in the standard rear  
facing configuration in a 42U or taller rack.  
NOTE: HP 480V Basic PDUs can only be mounted in the standard rear facing configuration.  
Easy Installation and  
compatibility  
Standard button and keyhole mounting provides simple drop in installation in HP 11000 G2 and Intelligent  
Series Rack and many third party racks.  
Warranty Upgrade  
Options  
HP Basic PDUs are backed by a limited 3-year warranty.  
HP Basic PDUs automatically assume the Care Pack coverage level of any covered ProLiant server in the  
same rack.  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Service and Support  
HP Basic Power Distribution Units  
HP Care Pack Services  
Care Pack services provide a range of life cycle support options that let you choose the service levels that  
meet your business requirements, from basic to mission-critical.  
A full range of HP Care Pack hardware and software services are available including:  
Installation and start up  
Education courses  
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7  
days call window with options including 4-hour response or 6-hour Call To Repair  
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and  
VMWare-based IT solutions helping to deliver high level of application availability. Response times  
range from 30 mins for critical problems to 2 hours.  
System Management, Performance Services and Mission Critical Support Solution  
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or  
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at:  
NOTE: Additional information regarding worldwide limited warranty and technical support is available at:  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Related Options  
HP Basic Power Distribution Units  
HP Country specific C19 HP C19 - Nema L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord  
AF593A  
AF592A  
AF584A  
AF582A  
AF583A  
PDU Inlet Cords for  
H5M56A and H5M57A  
(required)  
HP C19 - NBR-14136 BR 250V 16Amp 2.5m Power Cord  
HP C19 - GB-1002 CN 250V 16Amp 2.5m Power Cord  
HP C19 - IS-1293 IN/PK/BD 250V 16Amp 2.5m Power Cord  
HP C19 - ISI-32 IL 250V 16Amp 2.5m Power Cord  
HP C19 - AS3112-3 AU/NZ 250V 15Amp 3.6m Power Cord  
HP C19 - IEC-309 DK/SE/AR 250V 16Amp 3.6m Power Cord  
HP C19 - CEE-VII EU 250V 16Amp 3.6m Power Cord  
AF577A  
AF581A  
AF576A  
HP C19 - CEI-23-50 IT/CL 250V 16Amp 3.6m Power Cord  
HP C19 - SABS-164 ZA 250V 16Amp 3.6m Power Cord  
AF580A  
AF579A  
HP C19 - BS-1363/A UK/HK/SG 250V 13Amp 3.6m Power Cord  
HP 240 VAC 4.5M C19-Unterminated End NA Power Cord  
NOTE: HP Basic PDU models H5M56A and H5M57A require an IEC 320-C19 to country  
specific plug inlet cord which is sold separately.  
359615-031  
E7806A  
NOTE: Please refer to the Power Cord Matrix for more information on power cords/cable  
HP Jumper Cables  
HP C13 - C14 WW 250V 10A Gray 0.7m Jumper Cord  
HP IEC C13-C14 Cable Option Kit  
HP IEC320-C14 to C13 (10A/4.5ft/1.37m) PDU Cable  
HP C13 - C14 WW 250V 10A Gray 1.37m Jumper Cord  
HP IEC320-C14 to C13 10A/4.5ft/1.37m/ 15 PDU Cable  
HP C13 - C14 WW 250V 10Amp 2.0m Jumper Cord  
A0K03A  
142257-B28  
142257-006  
A0K04A  
142257-007  
A0K02A  
HP C13 - C14 WW 250V 10Amp Flint Gray 2.0m Jumper Cord  
HP IEC320-C14 to C13 (10A/8ft/2.5m) PDU Cable  
HP C13 Straight - C14 Straight WW 250V 10AMP 3.0m Jumper Cord  
HP C13 - C14 WW 250V 10A Gray 3.0m Jumper Cord  
HP C20 - C13 WW 250V 15Amp 2.0m Jumper Cord  
AF573A  
142257-002  
142257-003  
A0K06A  
AF590A  
HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord  
HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord  
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord  
AF575A  
AF574A  
295633-B22  
E7807A  
HP 200-250V 10A C15 to C14 .76m Jumper Cable  
NOTE: Please refer to the Power Cord Matrix for more information on power cords/cable  
HP Mounting Brackets  
HP Vertical PDU 10KG2 Mounting Kit  
H6L32A  
NOTE: Allows HP Basic PDU vertical models to be mounted in HP 10000 G2 series racks  
and in the HP V142 rack.  
HP 277 Volt options for HP LS-26 to LS-25 277 Volt 15Amp AC 0.76m Jumper Cord  
TK801A  
TK802A  
H3X09A  
H3X07A and H3X08A  
HP LS-26 to LS-25 277 Volt 15Amp AC 1.37M Jumper Cord  
HP 800VA - 277V Input / 230V Output NA Rack Mount Transformer  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Related Options  
HP Basic Power Distribution Units  
NOTE: 720 watt, 2U transformer converts 277V to 230V for up to 4 devices.  
NOTE: Please refer to the Power Cord Matrix for more information on power cords/cable  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Basic PDU Family Information  
HP Basic Power Distribution Units  
Model Selection Matrix  
HP Basic PDUs 1U/0U models  
Model  
Part Number Input Circuit Current  
Load capacity  
Input  
Connection  
Output circuit Outlet  
breakers Connections  
Maximum  
1.9kVA PDU  
H5M54A  
H5M56A  
100-127V  
20A  
16A  
1920VA @120V 8ft(2.4m) cord 1 x 20A  
with attached  
12 x NEMA 5-  
20R  
NEMA L5-20P  
3.6kVA PDU  
200-240V  
16-20A  
16A  
3680VA @230V Detachable  
input power  
1 x 16A  
12 x IEC C13  
cord with an IEC  
320-C20 inlet*  
Half Height vertical models  
Model  
Part Number Input Voltage Current  
Maximum  
Load capacity  
Input  
Connection  
Output circuit Outlet  
breaker Connections  
2.8kVA PDU  
H5M55A  
100-127V  
30A  
24A  
2880VA @120V 8ft(2.4m) cord 2 x 20A  
with attached  
18 x NEMA 5-  
20R  
NEMA L5-30P  
3.6kVA PDU  
H5M57A  
200-240V  
16-20A  
16A  
3680VA @230V Detachable  
input power  
2 x 16A  
20 x IEC C13  
cord with an IEC  
320-C20 inlet*  
4.9kVA PDU  
7.3kVA PDU  
8.6kVA PDU  
H5M58A  
H5M68A  
H5M61A  
200-240V  
30A  
24A  
32A  
4992VA @208V 8ft(2.4m) cord 2 x 20A  
with attached  
20 x IEC C13  
20 x IEC C13  
18 x IEC C13  
NEMA L6-30P  
200-240V  
32A  
7360VA @230V 8ft(2.4m) cord 2 x 16A  
with attached  
IEC 332P6  
200-208V 30A 41.5A  
3 phase Delta  
8646VA@208V3Ø 8ft(2.4m) cord 3 x 20A  
with attached  
NEMA L15-30  
Mid Height vertical models  
4.9kVA PDU  
7.3kVA PDU  
8.3kVA PDU  
11kVA PDU  
H5M59A  
H5M70A  
H5M60A  
H5M71A  
200-240V  
30A  
24A  
32A  
40A  
48A  
4992VA @208V 8ft(2.4m) cord 3 x 20A  
with attached  
24 x IEC C13  
6 x IEC C19  
NEMA L6-30P  
200-240V  
32A  
7360VA @230V 8ft(2.4m) cord 3 x 16A  
24 x IEC C13  
6 x IEC C19  
with attached  
IEC 332P6  
200-240V  
50A  
8320VA @208V 8ft(2.4m) cord 3 x 20A  
30 x IEC C13  
6 x IEC C19  
with attached  
CS8265C  
200-240V  
63A  
11040VA @230V 8ft(2.4m) cord 3 x 16A  
30 x IEC C13  
6 x IEC C19  
with attached  
IEC 363P6  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Basic PDU Family Information  
HP Basic Power Distribution Units  
Hardwired PDU H5M75A  
200-240V  
50-63A  
46A  
11040VA @230V Terminal block 3 x 20A  
30 x IEC C13  
6 x IEC C19  
for hardwired  
installation  
5.7kVA Dual  
Voltage PDU  
H5M63A  
H5M64A  
200-208V  
20A  
3 phase WYE  
27.7A  
41.5A  
5764VA @208 3Ø 8ft(2.4m) cord 3 x 20A  
with attached  
20 x IEC C13  
3 x NEMA 5-  
20R  
NEMA L21-20P  
8.6kVA Dual  
Voltage PDU  
200-208V  
30A  
3 phase WYE  
8646VA @208 3Ø 8ft(2.4m) cord 3 x 20A  
with attached  
20 x IEC C13  
3 x IEC C19  
3 x NEMA 5-  
20R  
NEMA L21-30P  
8.6kVA PDU  
11kVA PDU  
H5M62A  
H5M72A  
200-208V  
30A  
3 phase Delta  
41.5A  
8646VA @208 3Ø 8ft(2.4m) cord 3 x 20A  
with attached  
24 x IEC C13  
6 x IEC C19  
NEMA 15-30P  
380-415V  
16A  
16A per phase 11084VA  
@ 400V 3Ø  
8ft(2.4m) cord 3 x 16A  
with attached  
24 x IEC C13  
6 x IEC C19  
3 phase WYE  
IEC 516P6  
Full Height vertical models  
11kVA PDU  
H5M73A  
380-415V  
16A  
16A per phase 11040VA  
@ 400V 3Ø  
8ft(2.4m) cord 3 x 16A  
with attached  
36 x IEC C13  
6 x IEC C19  
3 phase WYE  
IEC 516P6  
11kVA PDU  
H5M67A  
380-415V  
30A  
24A per phase 11040VA  
@400V 3Ø  
8ft(2.4m) cord 3 x 20A  
with attached  
36 x IEC C13  
6 x IEC C19  
3 phase WYE  
IEC 530P6  
480/277 Volt models  
13.2kVA PDU H3X07A  
480V 30A 3  
phase WYE  
16A per phase 13301VA  
@480V 3Ø  
9.8ft(3M) cord 3 x 20A  
with attached  
IEC 530P7  
15 x LS-26  
30 x LS-26  
19.9kVA PDU H3X08A  
480V 30A 3  
phase WYE  
24A per phase 19952VA  
@480V 3Ø  
9.8ft(3M) cord 6 x 20A  
with attached  
IEC 530P7  
*NOTE: HP Basic PDU models H5M56A and H5M57A require an IEC 320-C19 to country specific plug inlet cord which is sold separately.  
NOTE: Please refer to the Power Cord Matrix for more information on power cords/cable part numbers, input/output descriptions.  
Disclaimer: HP makes no recommendations regarding power connector manufactures. Please consult a licensed professional to  
determine the best connector or receptacle for your specific needs.  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Technical Specifications  
HP Basic Power Distribution Units  
All PDUs  
Operating Temperature  
Operating Relative Humidity (%)  
Operating Elevation  
50° to 122° F (10° to 50° C)  
10% to 90%  
0 to 10,000 ft (0 to 3048 m)  
-4° to 140° F (-20° to 60° C)  
5% to 95%  
Storage Temperature  
Storage Relative Humidity (%)  
Storage Elevation  
0 to 30,000 ft (0 to 9144 m)  
96 inches (243.8 cm)  
UL, CUL - NA/JPN models  
Input Plug Length (attached cord units)  
Conformance Standards  
UL, CUL, CE, TUV, KC, EAC - WW models  
Mechanical Dimensions (WxHxD) - 1U/0U models  
17.5 x 1.66 x 6 in (44.45 x 4.2x 15.3 cm)  
1.9 x 29.02 x 3.75.0 in (48 x 73.7x 9.5 cm)  
Mechanical Dimensions (WxHxD) - Half Height  
models  
Mechanical Dimensions (WxHxD) - Mid Height models 1.9 x 55.12 x 9.5in (48 x 140 x 9.5 cm)  
Mechanical Dimensions (WxHxD) - Full Height models 1.9 x 61.07 x 3.75 in (48 x 155.1 x 9.5 cm)  
Mechanical Dimensions (WxHxD) - 480V Half Height 1.98 x 32.4 x 3.15 in ( 5.03 x 82.3 x 8 cm)  
Model  
Mechanical Dimensions (WxHxD) - 480V Full Height 1.98 x 62.9 x 3.15 in ( 5.03 x 159.7 x 8 cm)  
Model  
Kit Contents - All Basic PDUs  
All models ship with:  
Mounting brackets/hardware  
Cord Retention bracket  
Tie wraps  
Shipping bracket  
Read me first card  
Environment-friendly  
Products and Approach  
End-of-life Management Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling  
http://www.hp.com/go/green. To recycle your product, please go to:  
http://www.hp.com/go/green or contact your nearest HP sales office.  
Products returned to HP will be recycled, recovered or disposed of in a  
responsible manner.  
and Recycling  
The EU WEEE directive (2002/95/EC) requires manufacturers to provide  
treatment information for each product type for use by treatment facilities.  
This information (product disassembly instructions) is posted on the Hewlett  
used by recyclers and other WEEE treatment facilities as well as HP OEM  
customers who integrate and re-sell HP equipment.  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QuickSpecs  
Technical Specifications  
HP Basic Power Distribution Units  
© Copyright 2013 Hewlett-Packard Development Company, L.P.  
The information contained herein is subject to change without notice.  
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and  
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial  
errors or omissions contained herein.  
DA - 14557 North America — Version 7 — October 1, 2013  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graham Field Medical Alarms GF13605 User Manual
Graham Field Personal Lift lf 1031 User Manual
Hamilton Beach Coffeemaker 48463C User Manual
Honeywell Air Conditioner AMH 10000E User Manual
Hotpoint Oven osx 1036n dcx s User Manual
HP Hewlett Packard Personal Computer 413742 001 User Manual
Huffy Fitness Equipment 2145731 User Manual
Humax Cable Box CX FOX C II User Manual
iHome Battery Charger IB969 User Manual
Image Treadmill IMTL412050 User Manual