QuickSpecs
Overview
HP ProLiant BL30p Server Blade
HP ProLiant BL30p Server Blades Installed in HP BladeSystem p-Class Enhanced Server Blade Enclosure
1. HP ProLiant BL30p Server Blades (16)
2. ProLiant BL p-Class interconnects (2) (patch panel 2 shown)
What's New
Emulex based Dual port Fibre Channel HBA
HP McDATA 4 Gb SAN Switch for HP p-Class BladeSystem
Brocade 4Gb SAN Switch for HP p-Class BladeSystem
At A Glance
Maximum density HP ProLiant BL30p server blade
High density, dual-processor capable server blade for the ProLiant BL p-Class
Up to two Intel Xeon 3.2-GHz/533-MHz with 2MB L3 cache processors
ServerWorks GC-LE chipset
1024-MB PC2100-MHz Registered ECC DDR memory (1 x 1-GB), expandable to 4-GB, flex memory supports
interleaved and non-interleaved memory configurations
Integrated Lights-Out (iLO) Advanced Pack with new static IP bay configuration and HP BladeSystem wizard features
Two (2) NC7781 PCI-X Gigabit NICs (embedded)
One 10/100T NIC (embedded) dedicated to iLO management
Supports up to two optional small form factor ATA 60-GB hard drives
BIOS-Enhanced RAID for Linux enables both primary and secondary hard drives to be bootable
Dual-Port Fibre Channel Adapter (2-Gb) option for SAN connectivity
HP ProLiant BL30p server blade plugs vertically into blade sleeve and sleeve plugs into 6U blade enclosure
Local I/O cable provides two USB ports, one video port, one iLO port and serial port
Integrated Access Tool for blade management and enhanced server blade documentation including Best Practices and
Common Procedures guides
Up to 96 HP ProLiant BL30p server blades fit in 42U rack in non-redundant power configuration; up to 80 HP ProLiant
BL30p server blades fit in 42U in full power redundant configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 1
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
HP BladeSystem p-Class Blade Sleeve (holds 2 HP ProLiant BL30p server blades)
+
HP BladeSystem p-Class Enhanced Server Blade Enclosure
+
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 3
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
OR
Patch Panel (shown) or
Patch Panel 2
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch
or CGESM Interconnect Switch
(fiber or copper-based)
BL p-Class Interconnects
+
HP BladeSystem p-Class 3U power enclosure(s) and power supplies (three phase recommended)
OR
HP BladeSystem p-Class 1U power enclosures and power supplies
OR
Facility DC
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 4
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
OR
OR
Mini bus bars
Bus boxes
Scalable bus bars
Dual power input kit for mini bus bar option
HP BladeSystem p-Class power distribution (only required with 3U power enclosure)
Configuration Steps
For a complete HP ProLiant BL30p server blade solution, do the following:
1.
Select desired model, configuration and quantity of HP ProLiant BL30p server blades
PLUS
2.
Determine how many HP BladeSystem p-Class blade sleeves are required. Each p-Class blade sleeve holds two HP ProLiant
BL30p server blades and one server blade enclosure holds up to eight sleeves.
PLUS
3.
Determine how many HP BladeSystem p-Class Enhanced Server Blade Enclosures are required. Each enhanced server blade
enclosure can hold up to 16 HP ProLiant BL30p server blades.
NOTE: HP BladeSystem p-Class enhanced server blade enclosures are required to support HP ProLiant BL30p server blades.
Enhanced server blade enclosures can be purchased with licenses for Rapid Deployment Pack:
HP BladeSystem p-Class enhanced server blade enclosure with 8 Rapid Deployment Pack licenses (281404-B22)
Or
HP BladeSystem p-Class enhanced server blade enclosure with Rapid Deployment Pack trial (243564-B22)
Or
HP BladeSystem p-Class server blade enclosure with the HP BladeSystem Management Suite which is delivered in a
convenient to purchase pack that includes a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the
following products: Rapid Deployment Pack (RDP) Performance Management Pack (PMP) and the Vulnerability and Patch
Management Pack (VPM). (380625-B22)
PLUS
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 5
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
4.
Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects except the CGESM which includes a single
interconnect switch. One interconnect kit is required with each server blade enclosure:
RJ-45 Patch Panel 2 with Fibre Channel pass through. This is the required patch panel model for Fibre Channel connectivity
on HP ProLiant BL30p server blade (306465-B21).
Or
RJ-45 Patch Panel (230766-B21)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T
downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination
of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with
or without ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for
ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T
downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with (2) 10/100/1000 T/TX/T SFP
modules) (378927-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel
connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM
Interconnect Switch)
Or
BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink
ports ) (283192-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel
connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the GbE2
Interconnect Switch)
Or
BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000
T/TX/T uplink ports) (283193-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre
Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the
GbE2 Interconnect Switch)
PLUS
5.
Select HP BladeSystem p-Class power enclosure(s) and power supplies based on configuration.
NOTE: 3 phase power enclosure options are highly recommended for deployments of HP ProLiant BL30p server blades.
Use the ProLiant BL p-Class sizing utility to help determine power configuration:
NOTE: Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a maximum of four
power supplies) (NA/JPN- 239162-001) (INTL - 239162-421)
Or
Three-phase 3U power enclosure with six power supplies (Three-phase 3U power enclosure holds a maximum of six power
supplies) (NA/JPN- 230769-001) (INTL - 230769-421)
(3U Power enclosures and supplies can also be purchased separately see options list)
Or
1U power enclosure with six power supplies (378284-B21)
Or
1U power enclosure with two power supplies (380314-B21)
(Additional power supplies can also be purchased separately - see options list)
PLUS
6.
Select power distribution option (only required with 3U power enclosures):
Mini bus bars (support up to 3 server blade enclosures) (240559-B21).
NOTE: Two mini-bar configurations can be stacked to fill a 42U rack.
Or
Scalable bus bars (support up to 5 server blade enclosures*) (240560-B21)
Or
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 6
QuickSpecs
Overview
HP ProLiant BL30p Server Blade
Power Bus Box (supports a single server blade enclosure*) (240562-B21)
Or
Dual Power Input Kit for Mini Bus Bar - required for support of two power enclosures. (364565-B21)
Or
HP Modular Distribution Unit 40 Amp (NA/JPN) (P/N 252663-D75)**
Or
HP Modular Distribution Unit 40 Amp (Int'l) (P/N 252663-B34)**
Or
HP Modular Distribution Unit 32 Amp (Int'l) (P/N 252663-B33)**
Or
HP Modular Distribution Unit 24 Amp (NA/JPN) (P/N 252663-D74)**
*NOTE: Maximum depends upon power input
**NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-
class 1U power enclosure.
HP BladeSystem p-Class Enhanced Server Blade Enclosures Installed in 42U Rack
Redundant Power Configuration (left) and Non-Redundant Power Configurations (right)
1. HP BladeSystem p-Class Power Enclosure
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 7
QuickSpecs
Standard Features (Server Blade)
HP ProLiant BL30p Server Blade
Processor
Intel Xeon Processor 3.2-GHz/533-MHz with 2MB L3 cache
Intel Xeon Processor 3.2-GHz/533-MHz with 1MB L3 cache
Intel Xeon Processor 3.06-GHz/533-MHz with 512KB L2 cache
Upgradeability
HP ProLiant BL30p Server Blade is dual-processor capable
Cache Memory
One of the following
depending on Model
2-MB Level 3 cache
1-MB Level 3 cache
512-KB Level 2 cache
Chipset
ServerWorks GC-LE chipset
NOTE: For more information regarding the ServerWorks chipset, see the following website:
Memory Protection
Memory
Memory interleaving when an identical pair of DIMMs is installed (P/N 287494-B21)
Type
PC2100 DDR SDRAM running at 266MHz
Standard
1024-MB (1 x 1-GB)
NOTE: non-interleaved unless a second DIMM option installed 287497-B21
Maximum
4-GB
Network Adapter
Three (3) network adapters total:
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One 10/100T NIC (embedded) dedicated to iLO management
Integrated Manageability Integrated Lights-Out (iLO) Management Advanced Pack with new static IP bay configuration feature
iLO integrated HP BladeSystem wizard simplifies iLO, blade server and operating system installation and
configuration.
Internal Storage
Hard Drives
ATA
None ship standard
Maximum Internal
Storage
120-GB (2 x 60-GB small form factor ATA, 5400rpm hard drives)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 8
QuickSpecs
Standard Features (Server Blade)
HP ProLiant BL30p Server Blade
Fiber Channel on the HP The following items are needed to connect the HP ProLiant BL30p server blade to a SAN via Fibre
ProLiant BL30p server
blade
Channel:
1. HP ProLiant BL30p server blade with Dual-Port Fibre Channel Adapter (option) installed
The Dual-Port Fibre Channel Adapter option 354054-B21 is compatible with the HP ProLiant
BL30p server blade (not compatible with HP ProLiant BL20p server blades series)
Two ports on each configured blade provide redundant Fibre Channel connections
Supports up to 2 Gb/s Fibre Channel equipment
Based on the QLogic ISP2312 chipset
Kit includes two small form factor pluggable transceivers with LC connectors for installation into
the interconnect option kit (see 2A and 2B below)
AND
2A. RJ-45 Patch Panel 2 (with Fibre Channel pass through) interconnect option
Enables pass through of both Ethernet and Fibre Channel signals
Ethernet signals exit the rear of the RJ-45 Patch Panel 2 interconnects
Fibre Channel signals exit the front of the RJ-5 Patch Panel 2 interconnects
8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each
Patch Panel 2 interconnect (16 Fibre Channel SPF transceiver cages per server blade
enclosure)
SPF transceivers are included with the BL30p Dual-Port Fibre Channel Adapter kit (option)
OR
2B. C-GbE2 or F-GbE2 or CGESM Interconnect Kit plus the Storage Connectivity Kit (option)
Enables Ethernet signal consolidation and pass through of Fibre Channel signals
Both Ethernet and Fibre Channel signals exit the rear of the CGESM or GbE2 Interconnect Switch
(with the Storage Connectivity Kit option)
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the back of each
Interconnect Switch (16 Fibre Channel SPF transceiver cages per server blade enclosure)
SPF transceivers included with the BL30p Dual-Port Fibre Channel Adapter kit (option)
AND
3. Compatible SAN
Optimized for StorageWorks arrays:
Modular Smart Array 1000
Enterprise Virtual Array 5000 (EVA5000) V2; Enterprise Virtual Array 3000 (EVA3000)
XP48, 128, 512, 1024;
Compatible with select 3rd party SANs. Refer to blade storage website for details:
Local I/O Cable
No PCI slots, all features integrated
Two (2) USB ports, one (1) video port, one (1) iLO port and one (1) serial port
Two (2) Local I/O cables ship with each server blade enclosure with enhanced backplane components
(281404-B22 and 243564-B22)
NOTE: Tested USB devices (keyboard, mouse, floppy) are listed in options section below.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 9
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
HP ProLiant BL30p Server Blade
HP BladeSystem p-Class Enhanced Server Blade Enclosures and ProLiant BL p-Class
Interconnects
HP BladeSystem p-Class 6U (10.5-inch), 19-inch wide
Enhanced Server Blade
Enclosure
Holds up to:
Eight (8) HP ProLiant BL20p server blades series
Sixteen (16) HP ProLiant BL30p server blades series (HP ProLiant BL30p server blade sleeves
required)
Two (2) HP ProLiant BL40p server blades series
A combination of the above
NOTE: HP BladeSystem p-Class enhanced server blade enclosures are required to support HP ProLiant
BL30p server blades. See compatibility matrix:
NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components
and enables a field upgrade of a blade enclosure to support HP ProLiant BL30p server blades series and
provide a single, physical iLO port for the enclosure.
Two (2) outside bays for interconnects (Patch Panel, Patch Panel 2, GbE Interconnect Switch, GbE2, or
CGESM Interconnect Switch)
Server blade management module on the rear of the server blade enclosure is hot-plug, has a
centralized 10/100T iLO port for all installed blades, reports events of all installed blades and provides
asset and inventory information via SNMP.
HP BladeSystem p-Class Redundant 208V 30amp 3-phase 4 wire, NA
Power Requirements
Redundant 380 - 415V 20A 3-phase 5 wire, Intl
NOTE: 3 phase power highly recommended for BL30p deployments.
Redundant 200V - 240V AC, 30 amp single-phase for NA and International
Redundant -48VDC ± 10%
ProLiant BL p-Class
Interconnect Switch
Option
Interconnect Switch interconnects consolidate the Ethernet signals from the server blades to a smaller set
of external copper-based or fiber-based uplink ports for connection to the network infrastructure. Like the
Patch Panel interconnects, an option is also available to pass through individual HP ProLiant BL20p G2
and HP ProLiant BL30p Fibre Channel signals. The interconnect switches provide up to a 32-to-1 server
(A pair of switches per kit) network cable reduction per server enclosure depending on the mix of HP ProLiant BL20p server blade
series, HP ProLiant BL30p server blade series, and HP ProLiant BL40p server blades series. Each
(Each HP BladeSystem p-
Class server blade
enclosure requires a pair
of interconnects - patch
panels or interconnect
switches)
interconnect switch pair reduces up to sixteen internal server network (NIC) ports to one to six external
ports (four on a modular rear mounting interconnect and two on the switch front panel). This provides a
total of twelve external ports per server blade enclosure.
The Cisco GESM and GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require
network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant BL30p Fibre Channel
pass-through.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 10
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
HP ProLiant BL30p Server Blade
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kit is for applications that require
network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure. The CGESM
supports the same and HP ProLiant BL30p Fibre Channel pass-through as the GbE2.
The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one CGESM Interconnect
Switch or one CGESM Interconnect Switch populated with two (2) RJ-45 10/100/1000 T/TX/T
Small Form Factor Pluggable (SFP) Modules.
Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide two CGESM
Interconnect Switches providing any combination of up to twelve (12) RJ-45 10/100/1000 T/TX/T
or Fiber SX external ports per server blade enclosure.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for HP
ProLiant BL30p Fibre Channel pass-through when using either the CGESM Interconnect Kit.
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) provide NIC consolidation to 1000 Mbps (Gigabit
Ethernet), advanced network feature, Fibre Channel pass-through (for HP ProLiant BL20p server blade
series and HP ProLiant BL30p server blades series), and 1 Gigabit Ethernet bandwidth connectivity to the
network.
The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and
two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45
10/100/1000 T/TX/T external ports per server blade enclosure.
The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and
two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external
ports per server blade enclosure.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for Fibre
Channel pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit.
The GbE Interconnect Kits (C-GbE and F-GbE) provide NIC consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two
DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX
external ports per server blade enclosure.
The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two
QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-
45 10/100 T/TX external ports per server blade enclosure.
Also included (per Interconnect Switch):
One (1) RS-232 DB-9 front panel out-of-band management port
Redundant crosslink ports connecting the two interconnect switches
Redundant power inputs and on-board redundant fans
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
Power ON, management, and per port status and speed LED indicators
Reset/power momentary push-button switch
HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD
Fully pre-configured for rapid deployment and immediate operation
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter
consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two
DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX
external ports per server blade enclosure.
The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two
QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-
45 10/100 T/TX external ports per server blade enclosure.
ProLiant BL Interconnect Switch Management System and Utilities:
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 11
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
HP ProLiant BL30p Server Blade
Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level
user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging,
EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol,
broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP
client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and
duplex mode, and more.
ProLiant BL p-Class
The Storage Connectivity Kit (option) is required for Fibre Channel signal pass-through when using the
Storage Connectivity Kit CGESM or a GbE2 Interconnect Switch Kit. Both Ethernet cable consolidation and Fibre Channel
Option
(supports a pair of two
connectivity is possible using a single interconnect option. Order one Storage Connectivity Kit per server
blade enclosure for Fibre Channel pass through of HP ProLiant BL20p and HP ProLiant BL30p server
CGESM or GbE2 switches) blades series.
The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open
transceiver cages for the pluggable small form factor transceivers that come with each HP ProLiant
BL30p Dual-Port Fibre Channel Adapter (option) and each HP ProLiant BL20p Dual Port Fibre Channel
Adapter. The Storage Connectivity Kit supports up to eight HP ProLiant BL20p server blade series, up to
sixteen HP ProLiant BL30p server blades series or combinations thereof.
ProLiant BL p-Class
RJ-45 Patch Panel
(A pair of patch panels
provided per kit)
6U (10.5-inch), plugs into HP BladeSystem p-Class server blade enclosures.
Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45
connections.
Supports Gigabit Ethernet network adapters.
16 RJ-45 connectors on the back of each RJ-45 Patch Panel (32 RJ-45 connections per server blade
enclosure).
(Each server blade
enclosure requires a pair
of interconnects - patch
panels or interconnect
switches)
The benefits to the RJ-45 Patch Panel are that it:
- Allows the customer to connect signals to their own LAN infrastructure components.
- Provides very economical option enabling the lowest cost blade solution.
- Is completely passive and requires no software or management.
ProLiant BL p-Class RJ-45 6U (10.5-inch), plugs into HP BladeSystem p-Class server blade enclosures
Patch Panel 2 (with Fibre
Channel pass through)
connections.
Passes through Ethernet NIC signals, from all installed server blades, individually out as RJ-45
(A pair of patch panels
provided per kit)
Supports Gigabit Ethernet network adapters.
16 RJ-45 connectors on the back of each RJ-45 Patch Panel 2 (32 RJ-45 connections per server blade
enclosure).
(Each server blade
enclosure requires a pair
of interconnects - patch
panels or interconnect
switches)
Passes through Fibre Channel signals, from all installed HP ProLiant BL20p and HP ProLiant BL30p
server blades series, individually out through small form factor pluggable (SPF) transceiver cages.
Supports 2 Gb/s Fibre Channel signals and backward compatible with existing 1 Gb/s Fibre Channel
equipment.
NOTE: Either Patch Panel
2 or a Switch Interconnect
Kit is required for SAN
connectivity with HP
ProLiant BL20p server
blade series and HP
ProLiant BL30p server
blades series.
8 Fibre Channel small form factor pluggable (SPF) transceiver cages on the front of each Patch Panel 2
(16 Fibre Channel SPF transceiver cages per server blade enclosure).
The benefits to the RJ-45 Patch Panel 2 are that it:
- Allows the customer to connect signals to their own LAN and SAN infrastructure components.
- Provides a very economical option enabling the lowest cost blade solution.
- Is completely passive and requires no software or management.
- Electrically isolates the Ethernet and Fibre Channel signals from each other.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 12
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
HP ProLiant BL30p Server Blade
ProLiant BL p-Class Fibre Fibre Channel signals travel from a HP ProLiant BL20p server blade series and/or HP ProLiant BL30p
Channel pass through
server blades series through the server blade enclosure backplane. Fibre Channel signals are terminated
through the RJ-45 Patch Panel 2 CGESM or GbE2 Interconnect Switch (with Storage Connectivity Kit) in
the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals; one
Fibre Channel signal terminates through the right interconnect, the other Fibre Channel signal terminates
through the left interconnect.
Eight Fibre Channel small form factor pluggable (SPF) transceiver cages exist on the front of each RJ-45
Patch Panel 2 and rear of each GbE2 Interconnect Switch (16 Fibre Channel connections per server
blade enclosure). The SPF cages are used for insertion of SPF transceivers included with the HP ProLiant
BL20p G2 Dual-port Fibre Channel Mezzanine Card and the HP ProLiant BL30p Dual-Port Fibre
Channel Adapter.
Required Network
Cabling
10Base-T
Categories 3, 4 or 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
100Base-TX
1000Base-T
1000Base-SX
Category 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
50/125 µm Multimode Fiber, 400 MHz/Km (500 meters)
50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)
62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)
62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 13
QuickSpecs
Standard Features (Power System and Rack Information)
HP ProLiant BL30p Server Blade
HP BladeSystem
NOTE: To determine power configuration, please refer to the HP BladeSystem p-Class Overview and
p-class Power System and Planning Whitepaper and sizing utility at http://www.hp.com/products/servers/proliant-bl/p-class/info/.
Rack Information
HP BladeSystem p-Class 3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), dual input single
3U Power Enclosure
phase and three phase models available.
HP BladeSystem p-Class 3U power enclosure provides scalable rack-centralized, hot-plug power without
the need for PDUs.
Each 3 phase power enclosure houses six hot-plug power supplies
Each single-phase power enclosure holds four hot-plug power supplies
Please use the sizing utility to determine the power needed for each configuration
NOTE: 3 phase power enclosure options highly recommended for HP ProLiant BL30p server blade
deployments.
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using
facility DC, Facility DC Power Connection kit (240563-B21) is needed.
HP BladeSystem p-Class 1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single
1U Power Enclosure
phase or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power
enclosure houses up to six hot-plug power supplies to power up to one server blade enclosure, fully
populated with BL p-Class server blades and interconnects.
Please use the sizing utility to determine the power needed for each configuration
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using
facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.
HP BladeSystem p-Class In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or
Power Distribution (only facility DC power) is carried from the power enclosures to the server blade enclosures through bus bars
required with 3U power (for multiple enclosures) or power bus boxes (for a single enclosure). Hinges attach the HP BladeSystem
enclosures)
bus bars to the rack rails and provide easy rear access to the blade enclosures and interconnects. Power
is distributed through independent A- and B-sided bus bars.
Three power distribution solutions are available depending on the size of the intended deployment (see
table).
Power Enclosures Supported
Server Blade Enclosures
Max. Rack Space Occupied
Supported
up to 5
up to 3
1
Scalable Bus Bar
Mini Bus Bar
Power Bus Box
1 or 2
1 or 2*
1
36U
24U
9U
NOTE*: Dual power input kit for mini bus bar option (364565-B21) required to support two power
enclosures.
NOTE: To support a full 42U rack of BL p-Class server blades, use two stacked pairs of mini bus bars.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 14
QuickSpecs
Standard Features (Power System and Rack Information)
HP ProLiant BL30p Server Blade
Required Power Source
Two 30-Amp redundant power feeds per power enclosure
Connectors:
1.
NEMA receptacles (NA/Japan)
NA 1-phase L6-30, 250v, 30A 3-wire
NA 3-phase L15-30, 250V, 30A, 4-wire
IEC 309 Pin & Sleeve connectors (International)
Intl 1-phase 250V, 32A, 3- pin (2 pole + ground)
2.
Intl 3-phase 380-415V, 32A, 5--pin (4 pole + ground)
Optimized for power cabling from rack bottom and network cabling from rack top
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 15
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
ProLiant Essentials
Foundation Pack
Software for the ProLiant
BL Server
ProLiant Essentials Rapid Rapid Deployment Pack (RDP) is an automated deployment and provisioning
Deployment Pack
solution for all ProLiant servers. RDP includes the Altiris Deployment Solution
and ProLiant Integration Module featuring ProLiant server pre-configured
events for OS installation, and optimized software drivers, firmware and
management agents. Every RDP CD includes 10-node trial licenses for
evaluation purposes. RDP requires a license for each server deployed and
are available for purchase with blade servers. For more information, visit
HP Systems Insight Manger HP Systems Insight Manager (HP SIM) help maximize system uptime and
performance and reduce system maintenance costs by providing proactive
notification of problems before those problems result in unplanned downtime
or reduced productivity. HP SIM is easy to set up to work with the Insight
Management Agents, integrated Light-Out and Remote Insight Light-Out
Edition, and Version Control Agents to deliver robust fault, configuration,
and asset management as well as remote administration. With HP Systems
Insight Manager customers will also be able to take advantage of role-based
security; the ability to manage ProLiant, Integrity, and HP9000 systems; and
plug-ins for storage, client, printer, and power management as well as server
rapid deployment, performance management, and workload management.
For more details on HP Systems Insight Manager visit
Management Agents
The Management Agents form the foundation for HP's Intelligent
Manageability strategy. They provide direct, browser-based access to in-
depth instrumentation built into HP servers, workstations, desktops, and
portables, and send alerts to HP Systems Insight Manager and other
enterprise management applications in case of subsystem or environmental
failures. For additional information about the Management Agents and other
management products from HP, please visit the management Web site at
Subscriber's Choice
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based
email subscription service that provides software and driver change
notifications for ProLiant products. Sign up at
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
ROMPaq, support
software, and
configuration utilities
The latest software, drivers, and firmware fully optimized and tested for your
ProLiant server and options, available in the RDP CD, SmartStart or
downloadable from Software and Drivers download pages, linked from the
Insight Diagnostics Online The most advanced configuration analysis, reporting and troubleshooting
Edition utilities used by HP and at your fingertips, available in SmartStart.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL:
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 16
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
Optional ProLiant
Essentials Value Packs
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to
address specific business problems and needs:
Workload Management Pack - provides easier management of complex environments, improving
overall server utilization and enabling customers for the first time to confidently deploy multiple
applications on a single multiprocessor ProLiant Server.
Performance Management Pack - identifies and explains hardware performance bottlenecks on
ProLiant servers and attached options enabling users to better utilize their valuable resources.
Intelligent Networking Pack - detects and analyzes network bottlenecks or broken network linkages
and steers traffic to the optimum route based on network conditions.
Vulnerability and Patch Management Pack - identifies and remediates software security
vulnerabilities due to missing patches as well operating system configurations that can be
exploited by viruses, worms, and other blended threats.
Virtual Machine Management Pack - provides central management and control of virtual
machines from Microsoft and VMware. Integrated approach provides the ability to manage both
physical and virtual resources from a single management console. Integrated approach provides
the ability to manage both physical and virtual resources from a single management console.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer
to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product
QuickSpecs for more information.
SmartStart
SmartStart is a tool that simplifies single server setup, providing a rapid way to deploy reliable and
consistent server configurations. To obtain a copy of SmartStart for your blade server, redeem the
coupon that is included with your Blade server or order your copy from the SmartStart web site. For more
SmartStart version supported (minimum): SmartStart 6.20
OS Support
Microsoft® Windows®
LINUX
VMware Virtualization Software
NOTE: For a more complete and up-to-date listing of supported operating systems and versions, please
NOTE: For an up-to-date listing of the latest drivers available for the ProLiant BL p-Class, please visit the
NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware
Server Support Matrix at:
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 17
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
Factory Express Portfolio HP Factory Express offers configuration, customization, integration and deployment services for HP
for Servers and Storage servers and storage products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging, and custom packaging. HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000
servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and
configurable network switches.
For more information on Factory Express services for your specific server model please contact your sales
Intelligent Manageability Integrated Lights-Out (iLO) Advanced Pack
HP BladeSystem wizard - new feature iLO, blade and OS installation and configuration
Static IP bay configuration -- new feature for ProLiant BL p-Class blades
Virtual Text and Graphical Remote Console
Virtual CD-ROM and Virtual Floppy
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
Automatic Server Recovery-2 (ASR-2)
Redundant ROM
Remote Flash ROM
ROM Based Setup Utility (RBSU)
Advanced Configuration and Power Interface Specification Ready (ACPI)
Server and Interconnect Switch Health Logs
Redundant Power Supply Utility
Pre-Failure Warranty (covers processors, as well as hard drives and memory)
Interconnect Switch Management System and Utilities (Interconnect Switch option)
Integrated Management Log (IML)
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Network adapter teaming set-up utility
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 18
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
HP BladeSystem p-Class
Availability Features
Power redundancy:
hot-plug power supplies
redundant AC feeds (requires two power enclosures when using blade enclosures with
enhanced backplane components)
interconnects options and server blade management module share power from both A- and
B- side power buses
Dual-Port Fibre Channel Mezzanine Card for redundant SAN connections
Redundant ROM on each server blade
ECC Memory
Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load
balancing)
Interconnect Switch availability features:
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
Two network connections per HP ProLiant BL30p server blade routed to independent interconnect
switches
Redundant Ethernet inter-switch communication with two sets of redundant Ethernet uplink ports
per each interconnect switch
Redundant front panel ports per each interconnect switch for diagnostics, management, and
additional uplinks
Redundant serial ports
Compatibility with PVST+ (CGESM or GbE2 switch) and 802.1D Spanning tree protocol support
for loop-free path redundancy
Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and
failover
Redundant configuration files and operating system firmware images in memory (GbE2 switch)
Redundant fans per each interconnect switch
Redundant power to each interconnect switch
Support for ProLiant network adapter teaming
Redundant configurable community strings and SNMP trap manager hosts
Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)
Security
Power-on password
Administrator's password
Integrated Lights-Out provides user authentication via directory services or 12 customizable user
accounts
Integration Lights-Out supports SSH and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
Interconnect switch multilevel user names and passwords, management interface time out period setting,
SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication
and authorization*, and IP address restriction
*NOTE: CGESM or GbE2 Interconnect Switch only
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 19
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
Minimum Rack
Requirements
Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria:
Compatible with 19-inch Standard EIA rail sets
EIA rail-to-rail depth is 29 - 30"
Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from
rear RETMA rail to rear door, inclusive in the 36-inch overall depth)
Ample room for top and bottom cable egress (approximately 8 square inches for full rack
configuration with patch panel)
Must be capable of supporting 1600 lb (for full rack configuration)
Perforated front and rear doors to accommodate front-to-back cooling
Must have 65% open perforation on server blade enclosure doors to support airflow requirements
Optimized for use with the HP 10000 Series racks
NOTE: If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are
required.
Rack Airflow
Requirements
HP 10000 series racks provide enhanced airflow for maximum cooling, allowing racks to be fully
loaded with servers and server blades using the latest server technologies.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must
allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit
adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be
a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD
provided with the server, or to the server documentation located in the Support section on the HP
Service and Support
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of
processors, memory and SCSI hard drives). The warranty is fully supported by HP Services and a
worldwide network of resellers and service providers. In addition 90-day's getting started software
telephone support may be covered under the warranty or available for an additional fee. Enhancements
to warranty services are available through HP Care Pack services.
NOTE: Server Blade Limited Warranty includes 3 year Parts, 1 year Labor, 1-year on-site support.
NOTE: Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor,
3-year on-site support.
Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and
VMWare-based IT solutions helping to deliver high level of application availability. Response times
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 20
QuickSpecs
Standard Features (Manageability)
HP ProLiant BL30p Server Blade
range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution
HP has introduced a new building block approach which allows customers to purchase the right
coverage at the right time whether purchasing an initial server blade plus enclosure or purchasing
additional ProLiant server blades over time. HP will offer two sets of Care Pack services, one designed to
support the server blade and one designed to support the enclosure.
HP Care Pack services for HP ProLiant Server Blades cover the server blade and all HP branded
hardware options qualified for the server, purchased at the same time or afterwards, internal to the
server.
HP Care Pack services for HP BladeSystem p-Class Server Blade Enclosure covers the enclosure
including patch panels, HP supported Ethernet interconnects, power enclosure with power supplies and
power distribution.
NOTE: For more information regarding the Blade service portfolio visit our worldwide web site on the
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us
NOTE: Additional information regarding worldwide limited warranty and technical support is available
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 21
QuickSpecs
Models
HP ProLiant BL30p Server Blade
HP ProLiant BL30p X3.2-
2MB, 1GB (2P)
360329-B21
Processor(s)
Cache Memory
Memory
Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported)
2-MB Level 3 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running
at 266-MHz (1 x 1-GB); 2-way interleaved when an identical pair installed
Network Adapter
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
Hard Drives
None ship standard
Internal Storage
Optical Drive
Form Factor
Up to 120-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve
supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs
vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure.
ProLiant BL30p X3.2-
1MB, 1GB (2P)
368271-B21
Processor(s)
Cache Memory
Memory
Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported)
1-MB Level 3 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running
at 266-MHz (1 x 1-GB); 2-way interleaved when an identical pair installed
Network Adapter
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
Hard Drives
None ship standard
Internal Storage
Optical Drive
Form Factor
Up to 120-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve
supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs
vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure.
ProLiant BL30p
X3.06/533MHz-512KB,
1GB (2P)
Processor(s)
Cache Memory
Memory
Two (2) Intel Xeon 3.06-GHz standard (up to 2 supported)
512-KB Level 2 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running
at 266MHz (1 x 1-GB), 2-way interleaved when an identical pair installed
354566-B21
Network Adapter
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
Hard Drives
None ship standard
Internal Storage
Optical Drive
Form Factor
Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
None
Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve
supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs
vertically into HP BladeSystem p-Class Enhanced Server Blade Enclosure.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 22
QuickSpecs
Models
HP ProLiant BL30p Server Blade
ProLiant BL30p
X3.06/533MHz-512KB,
1GB (1P)
Processor(s)
Cache Memory
Memory
One (1) Intel Xeon 3.06-GHz standard (up to 2 supported)
512-KB Level 2 writeback per processor
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running
at 266-MHz (1 x 1-GB), 2-way interleaved when an identical pair installed
354050-B21
Network Adapter
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
Hard Drives
None ship standard
Internal Storage
Optical Drive
Form Factor
Up to 120-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-class blade sleeve. Blade sleeve
supports 1 or 2 HP ProLiant BL30p server blades. Blade sleeve plugs
vertically into ProLiant BL p-Class Enhanced Server Blade Enclosure.
ProLiant 3.2-GHz BL30p Processor(s)
Server Blade Multi-Pack
Each blade is configured with Two (2) Intel Xeon 3.2-GHz standard (up to 2
supported)
368272-B21
NOTE: Multi-pack
contains 8 HP ProLiant
BL30p server blades, 4 HP
ProLiant BL30p server
blade sleeves and 8
Cache Memory
2-MB Level 3 writeback per processor
Memory
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running
at 266-MHz (1 x 1-GB), 2-way interleaved when identical pair installed
Network Adapter
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
licenses for Rapid
Deployment Pack.
Hard Drives
None ship standard
Internal Storage
Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
ProLiant 3.06-GHz BL30p Processor(s)
Server Blade Multi-Pack
Each blade is configured with Two (2) Intel Xeon 3.06-GHz standard (up to 2
supported)
354051-B21
Cache Memory
Memory
512-KB Level 2 writeback per processor
NOTE: Multi-pack
contains 8 HP ProLiant
BL30p server blades, 4 HP
ProLiant BL30p server
blade sleeves and 8
licenses for Rapid
1024-MB (standard) to 4-GB (maximum) of PC2100 DDR SDRAM running
at 266-MHz (1 x 1-GB), 2-way interleaved when identical pair installed
Network Adapter
Two (2) NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE
One (1) 10/100T NIC (embedded) dedicated to iLO management
Hard Drives
None ship standard
Internal Storage
Up to 120-GB maximum (with optional hard drives) 2 x 60-GB
Deployment Pack.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 23
QuickSpecs
HP ProLiant BL30p Server Blade
Configuration Information - Factory Integrated Models (North America only)
NOTE: For Configure to Order requirements within EMEA region, please consult local Sales Contact.
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
Step 1: Base Server Blade Configuration
Model
HP ProLiant BL30p Configurable Model (North America)
367243-405
Configurable Model ships with:
- Two embedded NC7781 PCI-X Gigabit NICs plus one 10/100T NIC for iLO
- Integrated Lights-Out (iLO) Management with Advanced Pack features
Step 2: Choose Required Options (only one of the following from each list unless otherwise
noted)
Processor
Intel Xeon 3.06GHz/512-KB cache Processor Kit (option)
NOTE: If 2 processors are desired, select one 354053-L21and one 354053-B21
354053-L21
368273-L21
364306-L21
Intel Xeon 3.2GHz/533-1M cache Processor Kit (option)
NOTE: If 2 processors are desired, select one 368273-L21and one 368273-B21
Intel Xeon 3.2GHz/533-2M cache Processor Kit (option)
NOTE: If 2 processors are desired, select one 364306-L21and one 364306-B21
Memory
NOTE: Two-way interleaving memory is enabled when an identical pair of DIMMs is
installed.
For 1GB Total Memory choose A or B:
A) 2 x 512 MB PC2100 DDR SDRAM DIMMs
B) 1 x 1GB PC2100 DDR SDRAM DIMM
For 2GB Total Memory choose two:
1 x 1GB PC2100 DDR SDRAM DIMM
For 4GB Total Memory:
300679-B21
287497-B21
287497-B21
300682-B21
2 x 2048MB PC2100 DDR SDRAM DIMM 2x2048
Step 3: Choose Additional Options for Factory Integration
Hard Drive
ATA Hard Drive Kit for ProLiant BL35p and ProLiant BL30p, 2.5" parallel ATA drive,
354052-B21
354054-B21
60GB, 5400 rpm
Fibre Channel Option
Dual-Port Fibre Channel Adapter (2-Gb) Kit for HP ProLiant BL30p or HP ProLiant
BL35p server blades
NOTE: For additional options, including HP BladeSystem p-Class blade sleeve,
enhanced server blade enclosure, interconnect options and power subsystem options,
please refer to the "Options" section below.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 24
QuickSpecs
Options
HP ProLiant BL30p Server Blade
NOTE: Some options may not be factory integratable. Please contact your local sales representative for
additional information.
Unique Options
ATA Hard Drive Kit for ProLiant BL35p and ProLiant BL30p, 2.5" parallel ATA drive,
60GB, 5400 rpm (option)
354052-B21
354101-B21
HP BladeSystem p-Class Blade Sleeve Kit (option)
NOTE: Each blade sleeve supports one or two HP ProLiant BL30p/HP ProLiant BL35p
server blades.
ProLiant BL30p/BL35p
Emulex-based Dual Port Fibre Channel Adapter (2-Gb) Kit (option)
394588-B21
354054-B21
Dual-Port Fibre Channel NOTE: Supports the HP ProLiant 25p/30p/35p/45p Server Blades
Adapter
Dual-Port Fibre Channel Adapter (2-Gb) Kit (option) for HP ProLiant BL30p or HP
ProLiant BL35p server blades*
NOTE: This Fibre-Channel adapter is Qlogic-based
*NOTE: When using this adapter, Patch Panel 2, CGESM, or a GbE2 Interconnect
Switch Kit (with Storage Connectivity Kit) must be used to provide pass through of the
Fibre Channel signals.
ProLiant Essentials Value ProLiant Essentials Vulnerability and Patch Management Pack, 1-Server + 10 Desktop
389941-B21
Pack Software
Bundle License
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License
371645-B21
372029-B21
371646-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity
License
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for
New Servers
371647-B21
378372-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for
Installed servers
ProLiant Essentials Server Migration Pack, 25 - Server License
ProLiant Essentials Server Migration Pack, 50 - Server License
ProLiant Essentials Server Migration Pack, 100 - Server License
391674-B21
391675-B21
391676-B12
390739-B21
ProLiant Essentials Server Migration Pack, 10 - Server License
NOTE: This license allows 10 servers to be migrated from a physical server to 10
virtual machines. Or this license can be used to migrate 10 virtual machines from one
virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware
ESX or Microsoft Virtual Server 2005.
ProLiant Essentials Server Migration Pack, Single-Server License
ProLiant Essentials Server Migration Pack, Flexible-Quantity License
ProLiant Essentials Server Migration Pack, Tracking license
375345-B21
375346-B21
375347-B21
372214-B21
ProLiant Essentials Virtual Machine Management Pack, SINGLE LIC IP CCAO-
WGR
ProLiant Essentials Virtual Machine Management Pack, FLEX LIC IP CCAO-WGR
372215-B21
372216-B21
ProLiant Essentials Virtual Machine Management Pack, TRACKING LIC IP CCAO-
WGR
ProLiant Essentials Performance Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
306696-B21
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 25
QuickSpecs
Options
HP ProLiant BL30p Server Blade
ProLiant Essentials Performance Management Pack, 10-Server License
NOTE: For use with up to 10 servers. Contains 10 licenses with one unique license
activation key and documentation.
374055-B21
306697-B21
ProLiant Essentials Performance Management Pack, Flexible-Quantity License
NOTE: For use with multiple servers. This part number can be used to purchase
multiple licenses with a single activation key. The quantity ordered of this part number
will be the quantity of licenses included in the kit in the form of a corresponding
activation key. Use the same key to activate all licenses in the actual quantity ordered.
For a given order, one kit will be delivered with activation key, and documentation.
ProLiant Essentials Performance Management Pack, Tracking license
NOTE: For use with signed and implemented Activation Key Agreements only.
Purchase of this part number entitles the customer to deploy additional licenses of the
product under the terms of the existing Activation Key Agreement.
306698-B21
NOTE: Nothing is delivered in conjunction with the purchase of this part number. Visit
for more information on Activation Key Agreements.
Rapid Deployment Pack, 10 User, V1.x
269817-B21
269817-291
Rapid Deployment Pack, 10 User, V1.x (Japan)
NOTE: The above license allows 10 servers to be managed and deployed via the
Deployment Server.
NOTE: Not necessary if you purchase the HP ProLiant BL30p Multi-Pack (354051-
B21) or server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B22.
NOTE: Rapid Deployment pack is now available in a Linux Edition for Linux-only
environments.
Rapid Deployment Pack, 1 User, V1.x
267196-B21
267196-291
Rapid Deployment Pack, 1 User, V1.x (Japan)
NOTE: The above license allows 1 server to be managed and deployed via the
Deployment Server.
NOTE: Not necessary if you purchase the HP ProLiant BL30p Multi-Pack (354051-
B21) or server blade enclosure with 8 Rapid Deployment Pack licenses 281404-B22.
NOTE: Rapid Deployment pack is now available in a Linux Edition for Linux-only
environments.
Flexible Quantity License Kit
302127-B21
302128-B21
372906-B21
License-Only - for use with a Master License Agreement
ProLiant Essentials Intelligent Networking Pack, Single Server License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
ProLiant Essentials Intelligent Networking Pack, Flexible License
NOTE: For use with multiple servers. This part number can be used to purchase
multiple licenses with a single activation key. The quantity ordered for this part number
will be the quantity of licenses included in the kit in the form of a corresponding
activation key. Use the same key to activate all licenses in the actual quantity ordered.
For a given order, one kit will be delivered with the activation key, and
documentation.
372950-B21
ProLiant Essentials Intelligent Networking Pack, Tracking License
372951-B21
NOTE: For use with signed and implemented Activation Key Agreements only.
Purchase of this part number entitles the customer to deploy additional licenses of the
product under the terms of the existing Activation Key Agreement.
NOTE: Nothing is delivered in conjunction with the purchase of this part number. Visit
for more information on Activation Key Agreements.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 26
QuickSpecs
Options
HP ProLiant BL30p Server Blade
ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning
Manager version 2.0)
303284-B21
NOTE: For more information regarding ProLiant Essentials Software, please see the
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials
ProLiant Essentials Value Pack product QuickSpecs for more information.
Processor
Intel Xeon 3.06-GHz / 512-KB cache Processor Kit (option)
354053-B21
NOTE: There is no option kit offered for the HP ProLiant BL30p server blade with Intel
Xeon 3.2GHz processor because all models ship with two processors installed.
Memory
(SDRAM DIMMs)
4096-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 2-GB)
2048MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
2048 MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 2048 MB)
300682-B21
300680-B21
301044-B21
287497-B21
1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 1-GB)
NOTE: This DIMM option is an identical match to the DIMM installed on the HP
ProLiant BL30p server blade base model and therefore provides 2-way interleaving
when installed on a base model HP ProLiant BL30p server blade.
1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512-MB)
300679-B21
380625-B22
HP BladeSystem p-Class HP BladeSystem p-Class Enhanced Server Blade Enclosure with the HP BladeSystem
Enhanced Server
Blade Enclosures
Management Suite
NOTE: Includes an HP BladeSystem p-Class Enhanced Server Blade Enclosure, a
single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following
products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and
the Vulnerability and Patch Management Pack (VPM).
HP BladeSystem Management Suite (Software Licenses Only)
389403-B21
NOTE: Adds 8 licenses to ProLiant BL p-Class Server Blade Enclosure with the HP
BladeSystem Management Suite ,P/N 380625-B22 (above) for a total of 16 for a fully
populated enclosure of BL30p blades. Includes a single copy of Systems Insight
Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment
Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch
Management Pack (VPM).
HP BladeSystem p-Class Enhanced Server Blade Enclosure (includes enhanced
backplane components)
243564-B22
281404-B22
HP BladeSystem p-Class Enhanced Server Blade Enclosure with eight (8) ProLiant
Essentials Rapid Deployment Pack Licenses (includes enhanced backplane
components)
NOTE: HP BladeSystem p-Class enhanced server blade enclosures are required to
support HP ProLiant BL30p server blades.
HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)
NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced
backplane components and enables a field upgrade of a blade enclosure to support
HP ProLiant BL30p server blades series and provide a single, physical iLO port for the
enclosure.
354100-B21
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 27
QuickSpecs
Options
HP ProLiant BL30p Server Blade
HP BladeSystem p-Class ProLiant BL p-Class Patch Panel 2 Kit with Fibre Channel pass-through (pair)
306465-B21
Interconnects
NOTE: Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class Patch Panel (pair)
230766-B21
283192-B21
NOTE: Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches
and two QuadT2 Interconnect Modules)
NOTE: Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches
and two QuadSX Interconnect Modules)
283193-B21
378926-B21
378927-B21
NOTE: Only one interconnect kit required per server blade enclosure.
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit
Base Unit only
NOTE: Two CGESM interconnect kits required per server blade enclosure.
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit
Base Unit (populated with two RJ-45 10/100/1000 T/TX/T Small Form Factor
Pluggable (SFP) Modules
NOTE: Two CGESM interconnect kits required per server blade enclosure.
Cisco RJ-45 10/100/1000 T/TX/T SFP Module
Cisco Fiber SX SFP Module
378928-B21
378929-B21
321745-B21
ProLiant BL p-Class Storage Connectivity Kit (with pair of OctalFC Interconnect
Modules and two Fibre Channel signal conditioning cards)
NOTE: Required for HP ProLiant BL30p and HP ProLiant BL35p Fibre Channel signal
pass through when using the CGESM or GbE2 Interconnect Switch.
NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit.
NOTE: Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit
HP BladeSystem p-Class NOTE: Use p-Class sizing tool to help determine power configuration:
Power Options
Single Phase Power Enclosure with 4 power supplies (NA/JPN)
(Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to
order additional power supplies with this option kit)
239162-001
239162-421
230769-001
230769-421
Single Phase Power Enclosure with 4 power supplies (Int'l)
(Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to
order additional power supplies with this option kit)
3 Phase Power Enclosure with 6 power supplies (NA/JPN)
(3 Phase Power Enclosure holds a maximum of 6 power supplies; no need to order
additional power supplies with this option kit)
3 Phase Power Enclosure with 6 power supplies (Int'l)
(3 Phase Power Enclosure holds a maximum of 6 power supplies; no need to order
additional power supplies with this option kit)
Single Phase Power Enclosure (empty) (NA/JPN)
(Holds up to 4 power supplies; power supplies are not included in this kit)
231710-001
231710-421
231709-001
Single Phase Power Enclosure (empty) (Int'l)
(Holds up to 4 power supplies; power supplies are not included in this kit)
3 Phase Power Enclosure (empty) (NA/JPN)
(Holds up to 6 power supplies; power supplies are not included in this kit)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 28
QuickSpecs
Options
HP ProLiant BL30p Server Blade
3 Phase Power Enclosure (empty) (Int'l)
231709-421
(Holds up to 6 power supplies; power supplies are not included in this kit)
Single Power Supply
239161-B21
378284-B21
380314-B21
380312-B21
240563-B21
1U Power Enclosure with six power supplies
1U Power Enclosure with two power supplies
Single 1U power supply
Facility DC Power Connection
HP BladeSystem p-Class HP BladeSystem p-Class Scalable Bus Bar
240560-B21
240559-B21
364565-B21
240562-B21
252663-D75
252663-B34
252663-B33
252663-D74
Power Distribution (only
required with 3U power
enclosures)
HP BladeSystem p-Class Mini Bus Bar
Dual Power Input Kit for Mini Bus Bar
HP BladeSystem p-Class Power Bus Box
HP Modular Distribution Unit 40 Amp (NA/JPN)
HP Modular Distribution Unit 40 Amp (Int'l)
HP Modular Distribution Unit 32 Amp (Int'l)
HP Modular Distribution Unit 24 Amp (NA/JPN)
NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not
required with the HP BladeSystem p-class 1U power enclosure.
HP BladeSystem Power Extension Kit
381686-B21
NOTE: This kit is specifically for HP BladeSystem p-Class customers who want to
upgrade their standard server blade enclosures to enhanced server blade enclosures
and would like to install an additional, redundant 3U power enclosure above the
server blade enclosures rather than below them. The option kit consists of two
extension cable assemblies - one for each side (A and B).
SAN Switches
HP McDATA 4Gb SAN Switch
A8001A
A7533A
A7534A
A7535A
Brocade 4GB SAN Switch, Base
Brocade 4GB SAN Switch, full fabric
Brocade 4GB SAN Switch, power pack
HP BladeSystem p-Class HP BladeSystem p-Class Diagnostic Station
Other Options
230743-B21
293121-B21
HP BladeSystem p-Class Server Enclosure Shipping Bracket Option Kit
NOTE: Used to secure one server blade enclosure in a rack when moving.
HP BladeSystem p-Class Power Enclosure Shipping Bracket Option Kit
NOTE: Used to secure one power enclosure in a rack when moving.
365044-B21
HP BladeSystem p-Class Bus Bar Telco Rack Kit
HP BladeSystem p-Class Enclosure Telco Rack Kit
245249-B21
266076-B21
Tape Libraries
HP StorageWorks MSL6000 Tape Library
Ultrium 960 technology
MSL6030, 1 drive, 30 slots, Ultrium 960
MSL6030, 2 drive, 30 slots, Ultrium 960
MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router
AD606A
AD607A
AD608A
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 29
QuickSpecs
Options
HP ProLiant BL30p Server Blade
MSL6030, 2 drive, 30 slots, Ultrium 960, with embedded FC router
MSL6060, 2 drive, 60 slots, Ultrium 960
AD609A
AD610A
AD611A
MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router
SDLT 600 technology
MSL6026, 1 drive, 26 slots, SDLT 600
AD582A
AD583A
AD584A
AD585A
AD587A
AD588A
MSL6026, 2 drive, 26 slots, SDLT 600
MSL6026, 1 drive, 26 slots, SDLT 600, with embedded FC router
MSL6026, 2 drive, 26 slots, SDLT 600, with embedded FC router
MSL6052, 2 drive, 52 slots, SDLT 600
MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router
Ultrium 460 technology
MSL6030, 1 drive, 30 slots, Ultrium 460
AD598A
AD599A
AD600A
AD601A
AD603A
AD604A
MSL6030, 2 drive, 30 slots, Ultrium 460
MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router
MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router
MSL6060, 2 drive, 60 slot Ultrium 460
MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router
NOTE: Please reference the MSL6000 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks MSL5026S2 Tape Library
MSL5026S2, 1 drive, 26 slots, SDLT 320, RM
293472-B22
293472-B23
293472-B24
293472-B25
MSL5026S2, 2 drive, 26 slots, SDLT 320, RM
MSL5026S2, 1 drive, 26 slots, SDLT 320, RM with embedded FC router
MSL5026S2, 2 drive, 26 slots, SDLT 320, RM with embedded FC router
NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks MSL5052S2 Tape Library
MSL5052S2, 2 drive, 52 slots, SDLT 320, RM
293474-B21
293474-B24
MSL5052S2, 2 drive, 52 slots, SDLT 320, RM with embedded FC router
NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks MSL5060 Tape Library
MSL5060, 2 drive, 60 slots, Ultrium 230, RM
301899-B23
301900-B21
MSL5060, 2 drive, 60 slots, Ultrium 230, RM with embedded FC router
NOTE: Please reference the MSL5060 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
HP StorageWorks ESL E-Series Tape Libraries
ESL Extended 712e Tape Library, 0 drive, 712 LTO slots
AA934B
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 30
QuickSpecs
Options
HP ProLiant BL30p Server Blade
ESL Extended 630e Tape Library, 0 drive, 630 SDLT slots
AA935B
AA939B
AA940B
AD595A
AA937A
AA941A
AA936A
AA928A
ESL Extended 322e Tape Library, 0 drive, 322 LTO slots
ESL Extended 286e Tape Library, 0 drive, 286 SDLT slots
ESL E-Series Ultrium 960 drive kit
ESL E Ultrium 460 drive kit
ESL E-Series Ultrium 460-FC drive kit
ESL E SDLT 320 drive kit
ESL E e2400-FC 2G Interface Controller
NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution. Reference current compatibility information at
HP StorageWorks EML E-Series Tape Libraries
EML103e Tape Library, 0 drive, 103 LTO slots
EML 245e Tape Library, 0 drive, 245 LTO slots
AD560A
AD561A
NOTE: Please reference the EML E-Series Tape Libraries QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution. Reference current compatibility information at
HP StorageWorks Virtual Library Systems
HP 6105 Virtual Library System
AD728A
AD729A
HP 6510 Virtual Library System
NOTE: Please reference the Virtual Library Systems Tape Libraries QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution. Reference current compatibility information at
Magneto-Optical
Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
300mx, 2 drive, 32 slot jukebox
C1150M
C1160M
C1170M
600mx, 4 drive, 64 slot jukebox
700mx, 2 drive, 76 slot jukebox
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
1200mx, 4 drive, up to 128 slots
C1104M
C1105M
C1111M
C1107M
C1110M
1200mx, 6 drive, up to 128 slots
2200mx, 4 drive, up to 238 slots
2200mx, 6 drive, up to 238 slots
2200mx, 10 drive, up to 238 slots
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 31
QuickSpecs
Options
HP ProLiant BL30p Server Blade
NOTE: Please see the HP StorageWorks Magneto-Optical Products data sheet for a
complete listing of available jukeboxes at:
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution
HP StorageWorks Ultra Density Optical Storage
1000ux, 2 drive, 32 slot jukebox
AA965A
AA966A
AA968A
AA967A
AA969A
AA970A
AA973A
AA971A
AA972A
AA974A
1900ux, 4 drive, 64 slot jukebox
1900ux, 4 mixed drive, 64 slot jukebox
2300ux, 2 drive, 76 slot jukebox
3800ux, 4 drive, 128 slot jukebox
3800ux, 6 drive, 128 slot jukebox
7100ux, 4 drive, 238 slot jukebox
7100ux, 6 drive, 238 slot jukebox
7100ux, 10 drive, 238 slot jukebox
7100ux, 6 mixed drive, 238 slot jukebox
NOTE: Please see the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs
for a complete listing of available jukeboxes at:
NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at
http://www.hp.com/go/optical for additional information needed to create a
complete solution
HP StorageWorks
Modular Smart Array
1000
HP StorageWorks Modular Smart Array 1000
Modular Smart Array 1000 Controller
Modular Smart Array Fibre Channel I/O Module
Modular Smart Array hub 2/3
201723-B22
218231-B22
218960-B21
286763-B21
201723-B22
HP StorageWorks Modular Smart Array 1000
NOTE: Please see the StorageWorks Modular Smart Array 1000 QuickSpecs for
additional options and configuration information at:
(North America)
(Worldwide)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 32
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Cluster Options
ProLiant Cluster Kit with OpenView Storage Mirroring
364025-B21
364026-B21
364026-291
ProLiant Cluster HA/F200 for the Entry Level SAN
ProLiant Cluster HA/F200 for the Entry Level SAN
NOTE: For additional information regarding the ProLiant Cluster for HA/F100,
HA/F200 for Modular Smart Array 1000 please see the following QuickSpecs at:
(North America)
(Worldwide)
ProLiant Cluster Starter kit
364023-B21
NOTE: For additional information regarding the HP ProLiant Cluster for ProLiant
Cluster HA/F500 for Enterprise Virtual Array please see the following QuickSpecs at:
(North America)
(Worldwide)
NOTE: For additional information regarding the HP ProLiant Cluster for HA/F500
please see the following QuickSpecs at:
(North America)
(Worldwide)
USB Options
USB 1.44-MB External Diskette Drive (Carbonite)
USB Optical Scroll Mouse (Carbonite)
256MB HP Drive Key II (USB 2.0)
DC141B
DD441B
PH657A
HP Rack 5000 Series
(Graphite Metallic)
HP 5642 Rack - Unassembled
358254-B21
Rack Options for
Rack 5000 Series
(Graphite Metallic)
Stabilizer kit for 5642 Rack (Graphite Carbon)
NOTE: The stabilizing kit is used to prevent rack from tipping over
374493-B21
374499-B21
Baying Kit for 5642 Rack (Graphite Carbon)
NOTE: The baying kit is used to join two or more HP5642 racks.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 33
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Rack, HP Infrastructure 42U (HV)
379005-001
379006-001
257415-B21
Rack 10000 Series
(Graphite Metallic)
Rack, HP Infrastructure 42U (LV)
HP Rack 10842 (42U) - Pallet
NOTE: Server Blade Enclosures must be field integrated into the 10842 racks. Factory
integration of Server Blade Enclosures into the 10842 is not supported.
HP Rack 10842 (42U) - Shock Pallet
257415-B22
NOTE: Server Blade Enclosures must be field integrated into the 10842 racks. Factory
integration of Server Blade Enclosures into the 10842 is not supported.
HP S10614 (14U) Rack Cabinet - Shock Pallet
HP Rack 10647 (47U) Cabinet - Pallet
HP Rack 10647 (47U) Cabinet - Crated
HP Rack 10642 (42U) Cabinet - Pallet
HP Rack 10642 (42U) Cabinet - Shock Pallet
HP Rack 10642 (42U) Cabinet - Crated
HP Rack 10636 (36U) Cabinet - Pallet
HP Rack 10636 (36U) Cabinet - Shock Pallet
HP Rack 10636 (36U) Cabinet - Crate
HP Rack 10622 (22U) Cabinet - Pallet
HP Rack 10622 (22U) Cabinet - Shock Pallet
HP Rack 10622 (22U) Cabinet - Crated
292302-B22
245160-B21
245160-B23
245161-B21
245161-B22
245161-B23
245162-B21
245162-B22
245162-B23
245163-B21
245163-B22
245163-B23
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels)
-B23 (crated) used for air shipments of empty racks
Not all HP equipment is qualified to be shipped in the Rack 10000 series.
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as
height, width, depth, weight, and color:
(Worldwide)
(North America)
NOTE: For additional information regarding Rack Cabinets, please see the following
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 34
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Rack Options for HP
Rack 10000 Series
HP Rack Plinth Kit (Carbon)
251960-B21
361589-B21
246099-B21
246102-B21
255486-B21
HP Rack Light Kit (Neon)
42U Side Panel – Graphite Metallic
36U Side Panel – Graphite Metallic
47U Side Panel – Graphite Metallic
NOTE: For additional information regarding Rack Options, please see the following
TFT7210R Rack Mounted 17" Monitor
TFT5600 Rack Keyboard Monitor
1U Rack Keyboard & Drawer (Carbon)
348373-B21
221546-xx1
257054-xx1
Country Code Key (for TFT5600 RKM Rack Keyboard Monitor
(PN 221546-xx1)and 1U Rack Keyboard & Drawer (Carbon)(P/N 257-54-xx1))
XX = 00
XX = 03
XX = 04
XX = 05
XX = 06
XX = 07
XX = 08
US
XX = 09
XX = 10
XX = 11
XX = 13
XX = 18
XX = 29
XX = B3
Norway
UK
Sweden/Finland
Switzerland
Portugal
Germany
France
Italy
Belgium
Spain
Denmark
Japan
International
NOTE: For additional information regarding Rack Options, please see the following
NOTE: For a complete list of Monitors please view the following URL:
HP KVM Switch Options IP Console Switch Box (KVM/IP), 1 x 1 x 16
IP Console Switch Box (KVM/IP), 3 x 1 x 16
Serial Interface adapter - 1 Pack with power supply
Interface adapter - USB 1.0 (single pack)
CAT5e Cable 3', 4 pack
262585-B21
262586-B21
373035-B21
336047-B21
263474-B21
263474-B22
263474-B23
263474-B24
263474-B25
CAT5e Cable 6', 8 pack
CAT5e Cable 12', 8 pack
CAT5e Cable 20', 4 pack
CAT5e Cable 40', 1 pack
NOTE: For additional information regarding HP KVM Switches and options, please
see the following URL:
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 35
QuickSpecs
Options
HP ProLiant BL30p Server Blade
Service and Support
Offerings (HP Care Pack
Services)
NOTE: The HP Care Pack service part numbers below for ProLiant BL p-Class server
blades, cover the server blade and all HP branded hardware options qualified for the
server, purchased at the same time or afterwards, internal to the server.
Hardware Services On-site Service
Next Business Day On-Site Service, 5-Day x9-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
UD186E
UD187E
UD188E
UD189E
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
NOTE: The HP Care Pack service part numbers below for HP BladeSystem p-Class
server blade enclosure covers the enclosure including patch panels, HP supported
Ethernet interconnects, power enclosure with power supplies and power distribution.
Hardware Services On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
HC031E
HC032E
HC033E
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
NOTE: The HP Care Pack service part numbers below covers the HP BladeSystem
Brocade and McData SAN Switches.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage,
3 Years, Electronic
UC007E
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
UC008E
UC009E
UC023E
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Installation & Start-up Services
UC905E
HP Installation & Startup Service for HP BladeSystem Infrastructure - provides for an
integrated hardware and software implementation that includes remote service
planning, onsite deployment of hardware and software, installation verification testing
and customer orientation. Hardware deployment covers the installation of a single
BladeSystem enclosure that include server blades (up to 16), Ethernet network
interconnect, and power options. Software deployment covers the installation and
configuration of HP Systems Insight Manager (SIM), HP Rapid Deployment Pack (RDP),
and deploy up to two operating system editions of either Windows or Linux, using
scripted operating system installation software
UA219E
U4971E
U5683E
ProLiant BL p-Class Blade Server Hardware Installation, Electronic
ProLiant BL p-Class Enclosure and Server Blade Hardware Installation, Electronic
Provides for the Installation and Start-up of ProLiant Essentials Rapid Deployment Pack
on a Customer supplied server designated as a Deployment Server. Includes the
deployment of a single server. This new server will be deployed using either one of the
pre-configured scripts or an image. In addition, the service will provide for the capture
and storage of the configuration of the newly deployed server and orientation on
product usage. To be delivered during standard office ours, standard office days.
Electronic.
Provides for the Installation and Start-up of Rapid Deployment Pack Implementation of
Rapid Deployment Pack (Basic) (Electronic)
UA042E
Page 36
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
QuickSpecs
Options
HP ProLiant BL30p Server Blade
HP ProLiant Essentials Vulnerability and Patch Management Pack Installation and
Startup Service. Service coverage: onsite installation of the Vulnerability and Patch
UC929E
Management (VPM) software on a customer designated server, configuration of the
VPM software to acquire security patches, enabling the VPM software to scan up to
five (5) systems, applying the security patches to the designated servers, generating a
report from VPM that shows the vulnerability assessment results, and providing
customer with an orientation to the software.
Provides for the Installation and Start-up of System Insight Manager (Electronic)
Provides for the Installation and Start-up of System Insight Manager (Electronic)
UA041E
UA040E
NOTE: For more information, customer/resellers can contact
Software Operating Environment Care Packs
Microsoft Software Operating Environment Software Telephone 9x5 - 3 incident
(Electronic)
U8169E
U3402E
U9615E
U8222E
Red Hat Software Operating Environment Software Telephone 9x5 - 10 incident
(Electronic)
SUSE Software Operating Environment Software Telephone 9x5 - 3 incident
(Electronic)
ProLiant Essentials Operating Environment, - 5 Day, 8x5,1 year, 3 incident (Electronic)
NOTE: For more information, customer/resellers can contact
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 37
QuickSpecs
Memory
HP ProLiant BL30p Server Blade
HP ProLiant BL30p Server Blade (all models)
Standard Memory
1024-MB PC2100 MHz Registered DDR SDRAM DIMM installed (1 x 1-GB SDRAM DIMM)
Standard Memory Replaced with Optional Memory
Up to 4096-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional
SDRAM DDR DIMM memory expansion kits.
Memory
1024 MB
Slot
1
2
Standard
Optional
Optional
Maximum
1024 MB
512 KB
1024 MB
2048 MB
1024 MB
2048 MB
4096 MB
512 KB
1024 MB
2048 MB
Following are memory options available from HP:
4096-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
2048MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
2048 MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 2048 MB)
1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 1 GB)
1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
300682-B21
300680-B21
301044-B21
287497-B21
257974-B21
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 38
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
HP BladeSystem p-Class
Enhanced Server Blade
Enclosure
Dimensions
Height
10.5 in (26.67 cm)
Width
17.60 in (44.70 cm)
28.86 in (73.30 cm)
-43 VDC to -53 VDC Nominal -48 VDC
125 A at -48 VDC
Depth
Input Specifications
Rated input voltage
Rated input current
Rated input Power
Rated input voltage
Rated input current
Rated input Power
Operating
6000 W
Individual Server Blade
Bay Ratings
-43 VDC to -53 VDC Nominal -48 VDC
14.6 A at -48 VDC
700 W
Temperature Range
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
Non-Operating
Operating
Relative Humidity
(non-condensing)
Non-Operating
Operating
5% to 95%
Wet Bulb Temperature
82.4° F (28° C)
Non-Operating
101.7° F (38.7° C)
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for ProLiant
BLp-Class RJ-45 Patch
Panel 2 with Fiber
Channel pass through
Dimensions
Height
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
Width
Depth
Capability
IEEE 802.2, 802.3, 802.3u
10 Base-T (half-duplex)
10 Base-T (full-duplex)
Network Transfer Rate
10 Mbps
20 Mbps
100 Base-TX (half-duplex) 100 Mbps
100 Base-TX (full-duplex) 200 Mbps
1000 Base-TX (full-duplex) 1000 Mbps
Fiber Channel SAN
Connector
Velio VC1070 re-timer
Network
Auto-rate negotiate between 2G and 1G
32 RJ-45 in the back.
Fiber Channel SAN
10 Base-TX
16 Pluggable SFP optical cages in the front
Cable Support
Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)
100 Base-TX
Category 5 UTP (2 pair); up to 328 ft/100 m
Category 5E (4 pair); up to 328 ft (100 m)
SFP optical cable
1000 Base-TX
Fiber Channel
FCC Class A
EMI
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 39
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for ProLiant
BL p-Class RJ-45 Patch
Panel
Dimensions
Height
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
Width
Depth
Capability
IEEE 802.2, 802.3, 802.3u
10 Base-T (half-duplex)
10 Base-T (full-duplex)
Network Transfer Rate
10 Mbps
20 Mbps
100 Base-TX (half-duplex) 100 Mbps
100 Base-TX (full-duplex) 200 Mbps
1000 Base-TX (full-duplex) 1000 Mbps
Connector
Network
16 RJ-45 in the back
Cable Support
10 Base-TX
Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)
100 Base-TX
Category 5 UTP (2 pair); up to 328 ft (100 m)
Category 5E (4 pair); up to 328 ft (100 m)
1000 Base-TX
Power Requirements
Temperature Range
200 mA at + 5V DC; 500 mA at -48V
Operating
50° to 95° F (10° to 35° C)
Non-operating
Operating
-22° to 140° F (-30° to 60° C)
20% to 80%
Relative Humidity
(non-condensing)
Non-operating
Operating
5% to 95%
Wet Bulb Temperature
82.4° F (28° C)
Non-operating
101.7° F (38.7° C)
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for ProLiant
BL p-Class GbE
Interconnect Switch
Dimensions
Height
Width
Depth
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
Weight
11.5 lb/5.2 kg per interconnect switch
Performance
9.6 Gbps external port bandwidth per server blade enclosure (full duplex)
Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per
gigabit port, (64-byte packets)
Non-blocking, full-wire speed for all connections
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
Forwarding Mode
MAC Addresses
8,191 per interconnect switch; MAC address based filtering and MAC
address packet priority configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 40
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Forwarding Table
Maximum age: 1 to 1,000,000 seconds; default: 300 seconds
Age Time
Memory
32MB Main, 6MB flash and 16MB packet buffer per interconnect switch
Compliance
IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D,
802.1p, 802.3ac, 802.3ad (Static), and 802.1Q
SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC
2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674),
Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap
(RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch
MIBs and Environmental Traps
IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC
854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC
2131) and ZModem,
Network Transfer
Rate
10 Base-T (half-duplex)
10 Base-T (full-duplex)
10 Mbps
20 Mbps
100 Base-TX (half-duplex) 100 Mbps
100 Base-TX (full-duplex) 200 Mbps
1000 Base-TX (half and
full-duplex)
2000 Mbps
1000 Base-SX (full-duplex) 2000 Mbps
Connector
EMI
12 RJ-45, 2 DB-9 (C-GbE Interconnect Kit)
4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit)
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
Safety
UL/CUL Listed Accessory
CE
Power
-48VDC: 1050 mA, 50 W maximum (per interconnect switch)
Requirements
Temperature
R range
Operating
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
Non-operating
Operating
Relative Humidity
(non-condensing)
Non-operating
Operating
5% to 95%
Wet Bulb
82.4° F (28° C)
Temperature
Non-operating
101.7° F (38.7° C)
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for ProLiant
BL p-Class GbE2
Dimensions
Height
Width
Depth
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 41
QuickSpecs
HP ProLiant BL30p Server Blade
Technical Specifications
BL p-Class GbE2
Weight
12.0 lb/5.4 kg per interconnect switch
Interconnect Switch
Performance
24 Gbps External port bandwidth per server blade enclosure (full duplex)
Forwarding rate 1.5 million pps per gigabit port (64-byte packets)
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
Forwarding Mode
MAC Addresses
2,048 per interconnect switch
Forwarding Table
Age Time
Maximum age: 1 to 65535 seconds; default: 300 seconds
Memory
128MB Main, 32MB flash and 2MB packet buffer per interconnect switch
Compliance
IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D,
802.3ac, 802.3ad (Static), and 802.1Q
SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface
Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge
MIB , Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.3-2002 MIB,
SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote
Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and
Environmental Traps
RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5,
SCP v1.5, NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem
Network Transfer
Rate
10 Base-T (half-duplex)
10 Base-T (full-duplex)
10 Mbps
20 Mbps
100 Base-TX (half-duplex) 100 Mbps
100 Base-TX (full-duplex) 200 Mbps
1000 Base-TX (half and
full-duplex)
2000 Mbps
1000 Base-SX (full-duplex) 2000 Mbps
Connector
EMI
12 RJ-45, 2 DB-9 (C-GbE2 Interconnect Kit)
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit)
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
Safety
UL/CUL Listed Accessory
CE
Power
Requirements
48VDC: 2040 mA, 98 W maximum (per interconnect switch without Storage
Connectivity Kit)
48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage
Connectivity Kit)
Temperature
Range
Operating
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
Non-operating
Operating
Relative Humidity
(non-condensing)
Non-operating
Operating
5% to 95%
Wet Bulb
82.4° F (28° C)
Temperature
Non-operating
101.7° F (38.7° C)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 42
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for CGESM
Interconnect Switch
Dimensions
Height
Width
Depth
10.405 in (26.43 cm)
1.6 in (4.06 cm)
28 in (71.12 cm)
Weight
11.5 lb/5.2 kg per interconnect switch
Performance
28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum
Forwarding Rate (64 Byte Packets)
9018Bytes Jumbo Frames MTU
Non-blocking architecture. Wire Speed Performance on all ports
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
Forwarding Mode
MAC Addresses
Memory
8000 MAC/physical address Table Size
128MB DRAM Memory. 16MB Flash Memory
Compliance
IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full
duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree
Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3
10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE
802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification,
RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3 (RFC1493) ,
CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-MAN-MIB,
CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB, CISCO-
FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-
IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION-MIB,
CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB,
CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS-
MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE-
RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB,
ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not
supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH-
MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO-
SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per
the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my),
RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB,
SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB,
SNMPv2-MIB, TCP-MIB, UDP-MIB 1000BASE-T ports, 1000BASE-X (SFP),
1000BASE-SX
Network Transfer
Rate
10 Base-T (half-duplex)
10 Base-T (full-duplex)
10 Mbps
20 Mbps
100 Base-TX (half-duplex) 100 Mbps
100 Base-TX (full-duplex) 200 Mbps
1000 Base-TX (half and
full-duplex)
2000 Mbps
1000 Base-SX (full-duplex) 2000 Mbps
Connector
4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 43
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
EMI
FCC Part 15 Class A
EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24)
CNS 13438 Class A MIC
CD
MIC
AS/NZS 3548 Class A CE
VCCI Class A
Safety
Power
UL to UL 60950, Third Edition
C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition
TUV/GS to EN 60950:2000
CB to IEC 60950 with all country deviations
NOM to NOM-019-SCFI
CE Marking
-48VDC: 1050 mA, 125 W maximum (per interconnect switch)
Requirements
Temperature Range
Operating
50 to 95º F (10 to 35º C)
-22 to 140º F (-30 to 60º C)
20% to 85%
Non-operating
Operating
Relative Humidity
(non-condensing)
Non-operating
Operating
5% to 95%
Wet Bulb
82.4° F (28° C)
Temperature
Non-operating
101.7° F (38.7° C)
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for 3U HP
BladeSystem
p-Class Power Enclosures
(North America/Japan)
Single-Phase Model
5.25 in (13.34 cm)
27.15 in (68.96 cm)
17.60 in (44.7 cm)
47.5 lb (21.55 kg)
3-Phase Model
Dimensions
Weights
Height
Width
Depth
5.25 in (13.34 cm)
27.15 in (68.96 cm)
17.60 in (44.7 cm)
47.5 lb (21.55 kg)
No Hot-Plug
Power Supplies
All Hot-Plug
99.5 lb (45.13 kg)
125.5 lb (56.93 kg)
Power Supplies
Input Requirements
Rated input voltage
200 VAC to 240 VAC 200 VAC to 240 VAC
line to line
Rated input frequency
50 Hz to 60 Hz
24A
50 Hz to 60 Hz
24A per phase
Rated input current
per side
Rated input power
per side
5760 W
9976 W
Power cord
1 NEMA L6-30P per
side
1 NEMA L15-30 per
side
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 44
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Output Voltage
Specifications
Rated output voltage
Rated output current
Rated output power
Nominal power
-48.8 VDC to -54 VDC -48.8 VDC to -54 VDC
99A
170A
4298 W
8310 W
4158 W at 208 VAC
7202 W at 208 VAC
Ambient Temperature
Range (See NOTE)
Operating
50° to 95° F
(10° to 35° C)
50° to 95° F
(10° to 35° C)
Shipping
-22° to 140° F
(-30° to 60° C)
-22° to 140° F
(-30° to 60° C)
Relative humidity,
non-condensing
(See NOTE)
Operating
20% to 80%
20% to 80%
Non-operating
5% to 95%
5% to 95%
Wet Bulb
Operating
82.4° F (28° C)
82.4° F (28° C)
Temperature
Non-operating
101.7° F (38.7° C)
101.7° F (38.7° C)
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for 3U HP
BladeSystem
p-Class Power Enclosures
(International)
Single-Phase Model
5.25 in (13.34 cm)
27.15 in (68.96 cm)
17.60 in (44.7 cm)
47.5 lb (21.55 kg)
3-Phase Model
Dimensions
Weights
Height
Width
Depth
5.25 in (13.34 cm)
27.15 in (68.96 cm)
17.60 in (44.7 cm)
47.5 lb (21.55 kg)
No Hot-Plug
Power Supplies
All Hot-Plug
99.5 lb (45.13 kg)
125.5 lb (56.93 kg)
Power Supplies
Input Requirements
Rated input voltage
200 VAC to 240 VAC 6.25 A at -48 VDC
200 VAC to 240 VAC
line to neutral
Rated input frequency
50 Hz to 60 Hz
24A
50 Hz to 60 Hz
20A per phase
Rated input current
per side
Rated input power
per side
5760 W
10,552 W
Power cord
1 IEC 309 3-pin,
32A per side
1 IEC 309 5-pin,
32A per side
Output Voltage
Specifications
Rated output voltage
Rated output current
Rated output power
Nominal power
-48.8 VDC to -54 VDC -48.8 VDC to -54 VDC
99A
180A
4798 W
8790 W
4598 W at 208 VAC
8790 W at 230 VAC L-
N
Ambient Temperature
Range (See NOTE)
Operating
Shipping
50° to 95° F
(10° to 35° C)
50° to 95° F
(10° to 35° C)
-22° to 140° F
(-30° to 60° C)
-22° to 140° F
(-30° to 60° C)
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 45
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Relative humidity,
non-condensing
(See NOTE)
Operating
20% to 80%
20% to 80%
5% to 95%
Non-operating
5% to 95%
Wet Bulb
Operating
82.4° F (28° C)
82.4° F (28° C)
Temperature
Non-operating
101.7° F (38.7° C)
101.7° F (38.7° C)
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Performance
Specifications for HP
BladeSystem p-Class
Power Distribution
Devices
Power Bus Box
1
Mini Bus Bar
1 or 2
Scalable Bus Bar
1 or 2
Power
Enclosures or facility DC
feeds Supported
(3U each)
Server blade enclosures
supported
(6U each)
1
up to 3
24U
up to 5
36U
Total rack height of
supported enclosures
9U
Dimensions
Height
5.1 in (12.95 cm)
19.45 in (49.40 cm)
19.74 in (50.14 cm)
2.2 in (5.59 cm)
48.57 in (123.37 cm)
19.74 in (50.14 cm)
2.2 in (5.59 cm)
Width
3.6 in (9.14 cm) each
3.25 in (8.26 cm)
Depth
Weight
3.62 lb (1.64 kg)
13.2 lb (5.9 kg)
26 lb (11.79 kg)
Rated Operating
Voltage
-43.2 VDC to -54 VDC
-43.2 VDC to -54 VDC -43.2 VDC to -54 VDC
Max Total Power
Supported
3000 W
9000 W 15000 W
Total Max Input Current 69.44 A at -43.2VDC
At Minimum Voltage
208.32 A at -43.2 VDC 347.2 A at -43.2 VDC
(equivalent of 175A per
feed)
Total Max Input Current 62.5 A at -48VDC
At Nominal Voltage
187.5 A at -48 VDC
312.5 A at -48 VDC
(equivalent of 175A per
feed)
Max Current Per Power
Feed
70A
70A
210A
Max Local Ambient
Temperature
149° F (65° C)
149° F (65° C)
149° F (65° C)
NOTE: All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 46
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
Operating and
Performance
Specifications for
Facility DC
Voltage
Nominal input voltage
-48 VDC
Operating voltage range -48VDC ± 10% or -43.2 VDC to -52.8 VDC
Max Input voltage slew
rate
0.5V/uS
Redundant feed voltages* *A and B feeds must differ by no more than
(A & B)
5VDC during steady state operation
Ripple/Noise
Overshoot
480 mV PARD**
Must remain within regulation limits on all feeds
during startup or shutdown
Voltage transients
Must not exceed -60 VDC
Current
Max steady state input
current
62.5A per server blade enclosure installed at -
48VDC
Max steady state current
per feed/total
Power bus boxes
Mini bus bars
70 A/70A
210 A/210A
Scalable bus bars 210 A/350A or equivalent of 175A per feed*
In-rush current
Must support up to 2X the maximum operating current per server blade
enclosure (125 A) for up to 1.0 mS
Input over-current
Customer provided fusing for facility DC feeds that protects the system from
catastrophic over-current within 20 uS. Fuse should sustain all in-rush and
operating currents.
Max Input Current Slew 1A/uS
Rate
Max Rated Power
3000W per server blade enclosure
Connections and Cables HP provided facility DC cable connection kit:
The facility DC connection kit supports the connection of up to four -
48VDC, RETURN pairs and ground
The power cable assemblies consist of 1/0AWG, color-coded, flexible cable
rated at 105° C, terminated with bus mating connectors at one end and
unterminated at the other end. The cable length provided enables the
customer to route to a fuse panel within or adjacent to the rack.
NOTE: *All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B
feeds.
** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured
at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz
frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed
to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF
ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the
current. The printed wiring board assembly is installed in its enclosure for this measurement, or the
measurement leads are properly shielded with Earth grounds applied to the insert.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 47
QuickSpecs
Technical Specifications
HP ProLiant BL30p Server Blade
© Copyright 2005 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
Download from Www.Somanuals.com. All Manuals Search And Download.
DA - 11958
Worldwide — Version 19 — August 15, 2005
Page 48
|