HP Hewlett Packard Life Jacket HP NetRAID 4M User Manual

HP NetServer Installation Guide  
For the  
HP NetRAID-4M  
and  
â
Microsoft Cluster Services  
1 November 2001  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Installation Guide  
Contents  
Contents  
Introduction........................................................................................................................................iv  
Intended Audience..............................................................................................................................iv  
Recommended Reading ......................................................................................................................iv  
Version History ...................................................................................................................................v  
1 OVERVIEW........................................................................................................................................1  
1.1 Software and Networking Requirements........................................................................................1  
1.2 Hardware Requirements................................................................................................................1  
1.3 Installation Sequence – Important Note .......................................................................................1  
1.4 Alternative Installation Sequence...................................................................................................2  
2 NETRAID-4M – CLUSTER HARDWARE COMPONENT INSTALLATION ................................4  
2.1 Create Installation Floppy Diskettes ..............................................................................................5  
2.2 Install the NetRAID-4M and Heartbeat NIC..................................................................................6  
2.3 Set NetRAID-4M BIOS Options .................................................................................................10  
2.4 Install Windows 2000 Drivers .....................................................................................................11  
3 NETRAID-4M - INSTALLING WINDOWS 2000 CLUSTER SERVICES ....................................16  
3.1 Server A: Create Cluster Service User Account ...........................................................................17  
3.2 Server A: Install Cluster Services ................................................................................................18  
3.3 Server B: Install Cluster Services.................................................................................................24  
3.4 Configure the Cluster Shared Quorum.........................................................................................26  
3.5 Create Shared Quorum Cluster Resource .....................................................................................30  
3.6 Test the Shared Quorum Failover ................................................................................................33  
4 EXPAND SHARED STORAGE FOR CLUSTER SERVICES........................................................35  
4.1 Create Shared Disksets, Containers and NTFS Partitions .............................................................36  
4.2 Create NetRAID-4M Diskset Resources for Data Drives..............................................................38  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Installation Guide  
Introduction  
Introduction  
The following pages contain a cursory set of procedures for setting up the clustering  
components of HP NetServers with the HP NetRAID-4M disk controller running Microsoft  
Windows 2000 Advanced Server operating system. Steps include installing the HP NetRAID-  
4M controller and cabling it to the HP RS/12 Shared Storage enclosure, installing the HP  
D5013A network interface card for the intra-cluster network connection, installing Microsoft  
and HP cluster software, and configuring shared disk storage.  
For NetServer platform-specific descriptions of supported cluster configurations of Microsoft  
Cluster Server and the HP NetRAID-4M, refer to the configuration guides on the hp netserver  
Microsoft clusters web site. For more comprehensive information about installing, using and  
configuring disk arrays with the HP NetRAID-4M controller and the FAST (Flexible Array  
Storage Tool) utility, refer to the NetRAID series of accessory manuals available on the hp  
netserver information library web site.  
For more information about Microsoft Clustering technology, refer to the installation guides,  
support articles and technical papers on the Microsoft web site at www.microsoft.com, as well  
as Windows on-line help.  
Intended Audience  
This guide is for the person who installs, administers, and troubleshoots the Microsoft Cluster  
Server who needs cluster installation details specific to the HP NetRAID-4M controller.  
Hewlett-Packard assumes this person is qualified to service computer equipment and trained to  
recognize hazards in products with hazardous energy levels.  
NOTE  
Hewlett-Packard only supports and recommends installation of clustered HP  
NetServer systems using Microsoft Cluster Server software by a Microsoft or  
HP Cluster Certified Installer.  
Recommended Reading  
All downloadable from the hp information library web site, at:  
·
·
·
HP NetRAID 4M Installation Guide  
HP NetRAID 4M Installation Guide Supplement  
HP NetRAID 4M Command Line Users Guide - Performing tasks using the Flexible  
Array Storage Tool  
·
HP NetRAID 4M FAST Users Guide - Using the Flexible Array Storage Tool to  
configure and manage your RAID storage  
Key Chapters: Chapter 13, Managing Storage in a Cluster, introduces cluster  
concepts and highlights differences when running FAST in a cluster.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Installation Guide  
Introduction  
Chapter 14, Working with Disksets, explains how to manage a new  
object type called the diskset, which is required to create containers  
on shared storage.  
Chapter 15, Working with Diskset Resources, explains how to put  
containers hosted by disksets under the control of the MSCS cluster  
software.  
Version History  
1 November 2001  
22 March 2001  
16 March 2001  
15 March 2001  
Added note not recommending RAID-1 for shared quorum drive.  
Fixed step numbering in cabling section  
Added spare set note and force in optimization note.  
Initial release  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Overview  
1 Overview  
1.1 Software and Networking Requirements  
·
·
Microsoft Windows 2000 Advanced Server with the latest service pack installed on each  
server  
Administrator user login name and password for each node, and a domain account for the  
cluster service  
·
·
·
DNS, and computer, domain and cluster NetBIOS names  
TCP/IP, and static IP addresses for each network adapter, cluster service and IP resource  
HP NetServer Navigator CD, version L.20.00 or later, along with 8 floppy disks if driver  
diskettes are the method used as outlined in this guide, rather than browsing the CD, for  
driver and utility installation  
1.2 Hardware Requirements  
·
Two HP NetServers identically configured with processors, BIOS, memory, LAN  
adapter(s), disk drives, power supplies and cables in compliance with the corresponding  
HP Cluster Configuration Guide  
·
·
Two HP NetRAID-4M controllers (P9161A or D9351A) with termination and battery  
enable jumpers installed  
Two D5013B LAN adapter cards and a crossover cable or equivalent dedicated LAN  
connection to create the intra-cluster private network (embedded network interfaces can  
be used and are supported in platforms where they exist)  
·
RS/12 SCSI Storage enclosures (D5989C) containing two SCSI controller cards  
(D6025C), SCSI and power cables and HP disk drives  
1.3 Installation Sequence – Important Note  
The steps that follow serve as an example of one way to build a Microsoft two-node cluster  
with the HP NetServer, Rack Storage/12 and NetRAID-4M. Some of the steps may be done in  
a different sequence if preferred by the experienced installer.  
NOTE  
In systems using shared disk controllers other than the HP NetRAID-4M, when  
multiple nodes simultaneously access the same disk drives before Microsoft  
cluster services are installed, unpredictable drive configuration corruption can  
result. Presence of the cluster service software is necessary to protect the shared  
storage, enabling safely managed access by more than one server at a time.  
When the HP NetRAID-4M is used to connect shared storage, as long as the  
Clustering BIOS setting is enabled on each channel connected to drives in the  
shared storage enclosure, simultaneous access to the storage by the operating  
system on multiple nodes is safely managed.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Overview  
1.4 Alternative Installation Sequence  
NOTE  
For the purpose of illustration, the two server nodes depicted in this guide are  
referred to as Server A, or node A, the first node to establish the cluster, and  
Server B, or node B, the second node to join the same cluster. The ultimate  
assignments of cluster resources are not prescribed in this document. Those design  
considerations are at the discretion of the cluster planner.  
This guide was written in a sequence which directs each task in each subchapter be done first on  
Server A, then on Server B, before proceeding to the next topic, to ensure that the same actions are  
performed on both nodes in an identical fashion. Alternatively, if the installer wishes to complete  
as many steps as possible first on Server A before Server B, then the following sequence may be  
used; however, the installer must jump around in this document in order to do so.  
On Server A (B powered off)  
On Server B (A powered off)  
1. Install Windows 2000 Advanced Server, latest  
service pack, DNS, TCP/IP and public network.  
12. Install Windows 2000 Advanced Server, latest  
service pack, DNS, TCP/IP and public network.  
2. Chapter 3.1, steps 1-13  
13. Chapter 2.2, steps 13-15  
Create a domain user account for Cluster Service  
(Can be done at any time before installing cluster  
services.)  
Add 4M and D5013B card to a PCI slot in node B.  
Connect end of crossover cable to new B NIC.  
14. Chapter 2.2, step 26  
3. Chapter 2.2, steps 1-12  
If required, flash 4M firmware.  
Add 4M and D5013B card to PCI slots in node A.  
Connect one end of crossover cable to new A NIC.  
15. Chapter 2.3, steps 19-20  
4. Chapter 2.2, steps 16-25  
Boot and do Ctrl-A to set 4M BIOS options and  
verify drives in RS/12 are seen.  
If required, flash 4M firmware on A.  
5. Chapter 2.2, steps 27-29  
16. Chapter 2.4, steps 34-35  
Power off A and set switches on RS/12(s).  
Install 4M driver from diskette.  
6. Chapter 2.2, steps 30-35  
With A powered off. Cable shared storage to 4M  
card. Power on RS/12(s) to verify green LEDs.  
17. Chapter 2.4, steps 34-35  
Configure new private LAN connection.  
7. Chapter 2.3, steps 1-18  
18. Chapter 2.4, steps 34-35  
Boot and do Ctrl-A to set 4M BIOS options and  
verify drives in RS/12 are seen.  
Install 4M FAST utility from diskette or Navigator  
CD.  
8. Chapter 2.4, steps 1-11  
Install 4M driver from diskette.  
If all steps to the left have already been completed on  
Server A, Resume the sequence of this install guide at  
Chapter 3.2 to install cluster services and create shared  
quorum, data drives, etc.  
9. Chapter 2.4, steps 12-26  
Configure new private LAN connection.  
10. Chapter 2.4, steps 27-33  
Install 4M FAST utility from diskette or Navigator  
CD.  
11. Go to number 12 in the next column to configure  
node B.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
2 NetRAID-4M – Cluster Hardware Component Installation  
·
Create the installation diskettes required for the HP NetRAID-4M and HP NetServer  
10/100BaseT LAN Adapter (D5013B)  
·
Install the HP NetRAID-4M and HP D5013B LAN Adapter into each HP NetServer  
cluster node and connect the appropriate cables  
·
·
Update the HP NetRAID-4M firmware and configure the controller BIOS settings  
Install and configure the Windows 2000 drivers for both the HP NetRAID-4M and HP  
LAN Adapter  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
2.1 Create Installation Floppy Diskettes  
NOTE  
Refer to an HP NetServer Cluster Configuration Guide for the supported versions  
of the Navigator CD, server BIOS and NetRAID-4M firmware and driver.  
1. Power on Server A and immediately insert the HP NetServer Navigator CD-ROM into the  
Server A CD-ROM drive.  
2. Allow Server A to boot from the HP Navigator CD-ROM.  
3. If the HP Navigator prompts you to update the NetServer BIOS, do so and then return here  
to continue.  
4. Click the language box to select preferred language, then Continue.  
5. Verify or set today’s date and time and click Continue.  
6. From the menu, select the MS Windows 2000 Advanced Server - Cluster option and  
click Continue.  
7. Read the advisory note about Q252332. Because this configuration has the latest Service  
Pack installed which includes the referenced hot fix, this is no longer an issue. Click OK.  
8. Select the Diskette Library option to create the following installation diskettes:  
NOTE  
HP does not currently support loading drivers directly from the HP NetServer  
Navigator CD-ROM, but directory paths to the FAST and Cluster Kit installation  
utilities on the CD-ROM are provided later in this document.  
·
·
·
·
NOS Drivers (for the server model that you are using) – only one diskette is  
required, assuming that the HP 10/100BaseT LAN Adapter (D5013B) driver is  
already installed. (The second diskette in this option is for the LAN adapter drivers.)  
NetRAID Firmware: NetRAID-4M (D9161A, D9151A, D9352A) – Diskette 1 is  
bootable and runs a firmware flash utility. Two diskettes required or use the HP  
NetServer Navigator CD-ROM.  
NetRAID Software-NT/Win2000 (for NetRAID-4M) – contains the HP NetRAID-4M  
FAST (Flexible Array Storage Tool) Utility – three diskettes required or use the HP  
NetServer Navigator CD-ROM.  
NetRAID Software-NT/Win2000 Cluster (for NetRAID-4M) – HP NetRAID-4M  
Cluster Setup Software (Cluster Kit) – two diskettes required or use the HP  
NetServer Navigator CD-ROM.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
2.2 Install the NetRAID-4M and Heartbeat NIC  
1. Power off both Server A and Server B.  
2. Disconnect all cables from the back of Server A.  
3. If working on a racked server, extend the rack enclosure foot.  
4. Extend Server A and open the cover to gain access to the PCI slots.  
5. Insert an HP D5013B NIC into any 32-bit slot available in the server:  
6. Verify that the HP NetRAID-4M termination jumpers are installed as shown in the  
following graphic.  
Jumpers  
7. Verify the Battery Enable Jumper is properly installed on both pins as shown below.  
NOTE  
Note: The card ships from HP with this jumper installed on only one of the two  
pins.  
8. Insert the HP NetRAID-4M into any 64-bit PCI slot available in the server.  
9. Close Server A and if working on a racked server, slide the server back into the rack  
enclosure.  
10. Reconnect the video, keyboard, mouse, power, and network cables.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
11. Connect one end of a 10BaseT Crossover cable to the HP D5013B NIC that was just  
installed into Server A.  
12. DO NOT connect the HP NetRAID-4M controller SCSI cables at this time.  
13. Repeat the above steps, 1 through 8 to add the HP NetRAID-4M and HP D5013B NIC to  
Server B.  
14. Close Server B, and if working on a racked server, slide the server back into the rack  
enclosure, and then reconnect all cables.  
15. Connect the other end of the 10BaseT Crossover cable to the second HP D5013B NIC in  
Server B.  
CAUTION  
DO NOT connect the HP NetRAID-4M controller SCSI cables at this time.  
Update the NetRAID-4M Firmware  
16. Flashing from diskette -- At Server A, insert the HP NetRAID-4M firmware update  
diskette in the floppy drive and power the server on. Do not power on Server B at this  
time. Go to step 17.  
Or  
Flashing from CD-ROM --NetRAID-4M firmware can be flashed without diskettes by  
booting from the HP NetServer Navigator CD-ROM. The sequence of menu selections is:  
Configure the Server, Custom Setup, BIOS and Firmware Update, HP NetRAID-4M  
Adapter(D9161/D9351A).  
If the firmware listed under Version on server IS the latest supported version, remove the  
CD, power off the server, and skip to step 26, otherwise, if the Version on CD is desired,  
check the box next to HP NetRAID-4M Adapter (D9161/ D9351A), Continue, Choose  
Language, Continue. Skip to step 26.  
17. When the NetRAID-4M banners on the screen, note the firmware or build version, for  
example:  
NetRAID-4M BIOS v.2.4-0 [Build 4584]  
18. If the firmware IS the latest supported version, remove the floppy, power off the server,  
and skip to step 26, otherwise, proceed to the next step to update the firmware.  
19. If prompted with a message that the SCSI IDs are not responding, press Enter.  
20. When the server has booted to the HP NetRAID-4M firmware update diskette 1, select  
Update NetRAID Flash Image.  
21. Tab to select OK and press Enter to accept A:\as the directory for the flash image file.  
22. When prompted, insert the HP NetRAID-4M firmware update diskette 2 into the floppy  
drive of the server and press Enter.  
CAUTION  
DO NOT power off or reboot the server during the firmware update. If this  
should occur, the NetRAID-4M card will be made inoperable.  
23. Select OK to NOT reboot the server.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
24. When the update is complete, select the option to exit then press E to exit to DOS.  
25. Remove the floppy from the server floppy drive and power the server off.  
26. Repeat the previous steps 16 – 25 to update the firmware of the HP NetRAID-4M in  
Server B.  
Connect the NetRAID-4M SCSI Cables  
27. Verify that the HP RackStorage/12 units each have two SCSI Controller cards installed, as  
shown below:  
SCSI Controller Cards  
28. Change the HP RackStorage/12 unit option switch 1 (top) to the Cluster Mode position  
(right), as shown below:  
29. Insert disk drives into HP RackStorage/12 units, beginning with the left-most slot.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
CAUTION  
Connecting to adjacent channels, i.e.: 0 and 1, or 2 and 3, on the HP  
NetRAID-4M requires SCSI offset cables. Do NOT try and force connecting  
any other SCSI cables to channels next to each other or the controller may  
become damaged.  
30. As shown in the graphic above, using the appropriate SCSI cables, connect the Server A  
HP NetRAID-4M Channel-0 to an HP RackStorage/12 unit rear left SCSI card port.  
31. Connect the Server A HP NetRAID-4M Channel-1 to a different HP RackStorage/12  
unit, also to a rear left SCSI card port.  
32. Connect the Server B HP NetRAID-4M Channel-0 to the same HP RackStorage/12 unit  
as in step 30, this time, to the rear right SCSI card port.  
33. Connect the Server B HP NetRAID-4M Channel-1 to the same HP RackStorage/12 unit  
as in step 31, to the rear right SCSI card port.  
NOTE  
If more than two RS/12 SCSI cabinets are to be added to this cluster, attach other  
channels of the HP NetRAID-4M in a pattern consistent with the above diagram.  
34. Power on all HP RackStorage/12 units.  
35. Verify that the green indicator lights appear both on the front of the disk drives and on the  
SCSI connector card backplane of each HP RackStorage/12 before continuing.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
2.3 Set NetRAID-4M BIOS Options  
Set Controller Configuration Options  
1. Power on Server A. Do not power on Server B at this time.  
2. During the boot process, press Ctrl-A at the HP NetRAID-4M configuration prompt.  
CAUTION  
DO NOT allow the server to boot to Windows 2000 Advanced Server at this  
point.  
The screen will pause for a few or maybe several seconds while the HP NetRAID-4M  
detects the disk drives and displays the message:  
Waiting for Array Controller #0 to start….|  
3. Within the HP NetRAID-4M Controller Configuration Utility, select the SCSISelect  
Utility option.  
4. Select the Controller Configuration option.  
5. Verify that the Write Cache option is set to Disabled.  
6. To disable the HP NetRAID-4M BIOS, select Runtime BIOS and press Enter. Use the  
arrow key to select Disabled then press Enter. Press ESC to exit this screen and click Yes  
to save changes.  
Set SCSI Configuration Options  
7. Select SCSI Configuration and then select Channel 0. Press Enter.  
8. Verify or change the SCSI ID for the server that you are currently working on as follows:  
Server A:  
Server B:  
ID = 7  
ID = 6  
9. Change the Clustering option to Enabled and verify that the Domain Validation option  
is set to Enabled.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
NOTE  
When the Domain Validation feature is enabled, the HP NetRAID-4M controller  
performs a series of Read/Write buffer tests to check bus integrity and has the  
option of reducing the transfer rate if necessary, until data integrity is ensured.  
10. Press ESC and confirm to save changes by selecting Yes.  
11. On the same server, repeat the preceding steps for any used channels, including SCSI  
Channel 1, 2 , and 3. Be sure to use the same SCSI ID as used for Channel 0.  
Verify disk drives are operational  
12. Press ESC twice to return to the Main Menu.  
13. Select Disk Utilities. Press Enter.  
14. Select a Channel# and press Enter.  
15. The screen should display all of the drives in the HP RackStorage/12 that are attached to  
Channel#. In addition you should see devices on SCSI ID 6 or 7.  
NOTE  
The RackStorage/12 reserves SCSI ID 5 for the enclosure. On each used channel,  
SCSI ID 5 displays HP D5989x.  
16. Press ESC to back out and select each channel being used to verify that the drives are  
being seen.  
17. Press ESC and confirm the rebooting of the server by selecting Yes to exit the HP  
NetRAID-4M Controller Configuration Utility.  
18. After the server starts to reboot, power off the server.  
19. Repeat steps 1 – 17 above for Server B. (Be sure to use SCSI ID 6 for Server B).  
20. When finished with Server B, leave it powered off.  
2.4 Install Windows 2000 Drivers  
HP NetRAID-4M Disk Array Controller Driver  
1. Verify that the HP RackStorage/12 units are powered on.  
2. Power on Server A and allow it to fully boot to Windows 2000 Advanced Server.  
3. Log on.  
4. Wait for the Found Hardware Wizard screen to automatically appear and then click  
Next.  
5. Verify the Found Hardware Wizard (as shown below) is prompting to configure a RAID  
controller device. Select the option Search for a suitable driver for my device and then  
click Next.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
6. Insert the NOS Drivers diskette into the floppy drive.  
7. De-select all options for searching for the driver other than the Floppy Disk drives, click  
Next.  
8. When the wizard has located the HP NetRAID-4M array controller driver  
A:\oemsetup.inf, click Next.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
9. If there is no digital signature found, click Yes to continue.  
10. After the driver files for the controller, including the HP NetRAID-4M Management  
Device driver, have been copied from the floppy disk, click Finish.  
NOTE  
The NetRAID-4M management device communicates controller events to the  
Windows 2000 Advanced Server system event log (SOURCE = HPNMGT).  
11. Remove the HP NetRAID-4M driver diskette from the floppy drive.  
HP 10/100BaseT LAN Adapter (D5013B) NIC Driver  
12. From the Windows 2000 desktop, right-click the My Network Places icon and select  
Properties.  
13. From the toolbar, click on Advanced and select Advanced Settings.  
14. In the Connections panel verify or set the bindings to be in the following order and then  
click OK.  
Local Area Connection (Public)  
Local Area Connection x (Heartbeat)  
[Remote Access connections]  
15. Double-click on the Local Area Connection x (x being the number of the newly added  
D5013B NIC) icon, click the Configure button and then click on the Advanced tab.  
NOTE  
The icon will display a red X because the other node server is powered off.  
16. From the Property list select the Link Speed & Duplex option and then from the Value  
list select the 100 Mbps/Full Duplex option; click OK to continue.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
17. From the General tab screen, de-select all components from the middle panel other than  
Internet Protocol (TCP/IP).  
NOTE  
Microsoft recommends not installing the components: Client for Microsoft  
Networks, or File and Print Sharing for Microsoft Networks on the intra-cluster  
LAN.  
18. Click on the Internet Protocol (TCP/IP) component and then click the Properties  
button.  
19. Select the option to Use the following IP Address:.  
20. Enter a private IP address. For example:  
Server A:  
10.1.1.1  
10.1.1.2  
255.0.0.0  
Leave blank  
Server B:  
Subnet Mask:  
DNS Server:  
NOTE  
The client LAN IP and heartbeat LAN IP addresses must be on different subnets.  
The heartbeat LAN IP addresses on each node must be on the same subnet, and the  
client LAN IP’s on each node must be on the same subnet.  
21. Click the Advanced button.  
22. Click the DNS tab. De-select the Register this connection’s addresses in DNS and the  
Use this connection’s DNS suffix in DNS registration option will become unavailable  
(gray out).  
23. Click the Wins tab and select the Disable NetBIOS over IP option and then click OK.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Hardware, Drivers and Utilities  
24. Click Yes to acknowledge the empty WINS address message, and the click OK in the  
Properties window.  
25. Click OK to acknowledge the empty DNS list message. Click OK at the Properties  
window.  
26. Close the Network & Dial-up Connections windows.  
Install the HP NetRAID-4M FAST Utility  
27. Insert the first HP NetRAID-4M FAST Utility installation diskette in the floppy drive.  
28. Navigate to the A:\directory and double-click on setup.exe.  
Or  
If the HP NetServer Navigator CD-ROM is used, go to path:  
NSNavigator\periph\nraidadp\nt\us\setup.exe  
29. After clicking Next at the Welcome screen, fill out the name and company screen and  
click Next. Choose a path for the new folder and click Next, and Next again to accept the  
path.  
30. Select the option to perform a Full Install. Accept all defaults of the installation program.  
31. When prompted to restart the computer, remove the floppy diskette from the floppy drive,  
select Yes and then click Finish.  
32. Power on Server B, allowing Server B to boot to Windows 2000 Advanced Server.  
33. Log onto Server B.  
34. Repeat the previous steps 1 through 32 on Server B to install the HP NetRAID-4M Disk  
Array Controller driver and FAST utility and configure the IP addressing for the heartbeat  
LAN Adapter (D5013B).  
35. Restart Server B.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
3 NetRAID-4M - Installing Windows 2000 Cluster Services  
·
·
·
·
Install Windows 2000 Cluster Services on both cluster nodes  
Install HP NetRAID-4M cluster add-on software on both cluster nodes  
Use the HP NetRAID-4M FAST utility to configure and initialize shared storage space  
Use the Windows 2000 Disk Management utilities to create and initialize the shared  
quorum partition  
·
·
Use the Windows 2000 Cluster Administrator utility to create and assign the shared  
quorum resource to the cluster  
Use the Windows 2000 Cluster Administrator utility to test the shared quorum by  
initiating a Cluster Group fail-over  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
3.1 Server A: Create Cluster Service User Account  
1. Log on to the domain at Server A as an administrator.  
2. Open the Active Directory Users and Computer utility from the Administrative Tools  
Start menu.  
3. Expand the appropriate domain folder in the left panel.  
4. Click once on the Users folder n the left panel.  
5. Click the Action button and select New and the click on User.  
6. Enter the Full Name: Cluster Services Account  
7. Enter a logon name for this service (e.g.: MSCS) and then click Next.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
8. Enter a password for the cluster service user account.  
9. Select the options User cannot change password and Password never expires. Click  
Next and then click Finish.  
10. Add the new user to the Domain Administrator group by right-clicking on the Cluster  
Service username in the right pane and selecting Add members to group.  
11. Select the group, Domain Admins, then OK.  
12. Click OK to the notice that the Add to group was successful.  
13. Close the Active Directory Users and Computer utility.  
3.2 Server A: Install Cluster Services  
1. On Server A, open the Windows 2000 Control Panel and double-click the Add/Remove  
Programs icon.  
2. In the Add/Remove Programs screen, in the left pane, click on the Add/Remove  
Windows Components option.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
3. Select the Cluster Service option from the list of services and click Next.  
4. Insert the Windows 2000 Advanced Server CD-ROM in the CD-ROM drive. If the  
Windows 2000 Advanced Server splash screen appears, click Exit.  
5. At the message, Please insert Compact Disc labeled ‘Windows 2000….click OK.  
6. At the Cluster Service Configuration Wizard, click Cancel, as shown below.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
7. Click Yes to the prompt to exit the setup.  
8. Click Finish to close the Cluster Service Installation wizard.  
9. Close the Add/Remove Programs and Control Panel windows.  
CAUTION  
For the NetRAID-4M/Server A installation, DO NOT continue past this point  
using the standard Cluster Service Installation wizard.  
10. Open a command prompt and type:  
C:\winnt\cluster\cluscfg –localquorum <Enter>  
This will restart the Cluster Service Configuration wizard in a “local quorum” installation  
mode.  
11. Click Next at the Cluster Service Configuration wizard screen.  
12. Select the I understand … option and click Next.  
13. Select the option The first node in the cluster, click Next.  
14. Enter a name for the cluster.  
(Example: Cluster1.)Click Next.  
15. Enter the cluster service username and password.  
(Example: MSCS/password) Click Next.  
16. At the Configure Cluster Networks screen click Next.  
17. In the Network Connection screen (shown below) enter the intra-cluster (heartbeat) LAN  
name, (e.g.: Heartbeat), and it’s IP address, (e.g.: 10.1.1.1).  
18. Select the Enable this network for cluster use option, then select Internal cluster  
communications only and then click Next.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
19. On the second Network Connection screen, enter the public LAN name, (e.g.: Public  
Network), and an IP address and then select the option to Enable this network for  
cluster use. Click All communications, then click Next.  
20. Verify that the heartbeat network connection is listed at the top of the priority list. If it is  
not, use the up and down arrow buttons on the right of the screen to move it to the top.  
Click Next.  
21. Enter a Cluster IP Address and subnet mask that is accessible to the client (public) LAN.  
Click Next to continue.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
22. Click Finish to complete the installation of Cluster Services.  
23. At the prompt that Cluster Services has successfully started, click OK.  
24. Exitthe command prompt window.  
Server A: Install HP NetRAID-4M Cluster Add-on Software  
NOTE  
The HP NetRAID-4M cluster software contains a Hewlett-Packard extension to  
the Microsoft Cluster Administrator utility (provided with the Microsoft Cluster  
Service software). The Hewlett-Packard extension consists of a resource DLL and  
an administrative DLL which enables use of Cluster Administrator, in addition to  
FAST and the CLI (Command Line Interface), to manage shared storage.  
25. Remove the Microsoft Windows 2000 Advanced Server CD-ROM from the CD-ROM  
drive.  
26. Insert the HP NetRAID-4M Cluster Setup diskette #1 in the floppy drive of Server A.  
Navigate to the A:\ directory and double-click on: setup.exe.  
Or  
If the HP NetServer Navigator CD-ROM is used, go to path:  
NSNavigator\periph\nraidadp\nt\cluster\setup.exe  
27. Accept the defaults in the installation screens. For the type of installation, select the  
Cluster Node option. Click Next.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
25. When the HP NetRAID-4M Cluster software installation is complete, remove the diskette  
from the floppy drive. Click Finish.  
26. Open the Cluster Administrator utility, Start > Programs > Administrative Tools >  
Cluster Administrator. You should see Server A in an Up” operational state as shown  
below.  
27. Leave Server A running.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
3.3 Server B: Install Cluster Services  
1. Log onto Server B.  
2. Open the Control Panel screen and double-click on the Add/Remove Programs icon.  
3. Click on the Add/Remove Windows Components and select the Cluster Service option.  
Click Next to continue.  
4. Insert the Windows 2000 Advanced Server CD-ROM into the server CD-ROM drive. If  
the Windows 2000 Advanced Server splash screen appears, click Exit.  
5. Click Next at the Welcome to the Cluster Service Configuration Wizard screen.  
6. Click the I understand … option and then click Next.  
7. Select the Second node in the cluster option and click Next.  
8. Enter the cluster name. (Example: Cluster1)  
9. Select the option to Connect to cluster as and enter the cluster service user name and  
password (e.g.: MSCS/password) and then click Next.  
If an error appears saying that the username is not valid, go to Active Directory Users  
and Computers. Click on Users and if the user Cluster Service does not display,  
click Refresh. Verify that the Cluster Service username appears before returning to the  
next step.  
10. Reenter the password and then click Next.  
11. Click the Finish button to complete the installation on Server B.  
12. Click OK to the message that the Cluster Services have successfully started.  
13. Wait for the Cluster Service Installation wizard screen to return and then click Finish.  
14. Click the Close button to close the Add/Remove Programs window and then close the  
Control Panel window.  
15. Open the Cluster Administrator utility on Server B and you should now see both Server  
A and Server B in Up” operational states as shown on the next page:  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
Server B: Install HP NetRAID-4M Cluster Add-on software  
16. Remove the Microsoft Windows 2000 Advanced Server CD-ROM from the CD-ROM  
drive.  
17. Insert the first NetRAID Software-NT/Win2000 Cluster Installation diskette in the floppy  
drive of Server B (or insert the Navigator CD-ROM).  
18. Navigate to the A:\ directory and double-click on: setup.exe  
Or  
If the NetServer Navigator CD-ROM is used, go to path:  
NSNavigator\periph\nraidadp\nt\cluster\setup.exe  
19. Accept the defaults in the installation screens. For the type of installation, select the  
Cluster Node option.  
20. When the HP NetRAID-4M Cluster software installation is complete, remove the  
installation media from the drive.  
CAUTION  
Whenever you remove and reinstall the MSCS software, you must also  
remove and reinstall the HP NetRAID-4M Cluster software. Because the  
custom DLLs provided by the HP NetRAID-4M Cluster software are not part  
of the standard MSCS software, these components must be registered each  
time the MSCS software is reinstalled.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
3.4 Configure the Cluster Shared Quorum  
Using the NetRAID-4M FAST Utility  
1. On Server A, from the Windows 2000 Start button start the NetRAID-4M FAST utility.  
2. Verify that the Available Controllers window displays the local HP NetRAID-4M and click  
Open.  
3. Expand the Controller View window.  
Create Disksets  
NOTE  
A diskset cannot span disks across multiple controllers.  
4. From the Disk (Physical Drv) menu, click on the Manage Disksets button.  
5. To create a shared quorum drive on a RAID-5 set, select 3 or more Disk ID’s from the  
Non-Member Disks listing, then click the Create Diskset …>> button.  
NOTE  
HP recommends creating a fault-tolerant RAID type, such as RAID-5 for the  
shared quorum drive. RAID-1 mirrors are NOT recommended for the shared  
quorum when using the HP NetRAID-4M controller.  
6. Enter a Diskset name from 1 to 32 characters. (Example: QuorumDiskSet)  
NOTE  
Diskset names must be unique within the cluster.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
7. Leave the options Attached and Re-initialize disk selected.  
NOTE  
The Attached check box allows you to specify whether or not the diskset is  
attached immediately after it is created (thereby making container information on  
the member disks accessible to the controller).  
Re-initialize disks check box allows you to specify whether existing container  
information is to be removed from the disks being used to create the diskset  
Spare set creates a diskset of hot spares that can later be assigned as global or  
dedicated hot spares to NetRAID-4M containers (logical drives).  
8. Click OK, then click the Close button to complete the drive selections.  
Create Containers  
9. Select the Container (Logical Drv) menu and click on the Creation Wizard option.  
10. From the Diskset drop list, select the newly created diskset (e.g.: QuorumDiskSet).  
11. To create a RAID-5 set for the quorum drive, from the Type to create pulldown menu  
select RAID-5 set.  
NOTE  
Please refer to the HP NetServer Cluster Configuration Guide for a complete  
listing of supported configurations.  
12. Click the Force in Dest check boxes.  
NOTE All of the originally selected non-member disks are considered for inclusion in the  
destination container; but, only those disks with an X in the right-hand In Dest  
column are actually included in the destination container. Disks whose Force in  
Dest check boxes are checked are forced to be included in the container.  
Force in Dest is particularly useful when reconfiguring containers when, for  
example, a rebuild to a hot spare has occurred and the administrator wishes to  
move the array back to the original drive positions after the bad drive has been  
replaced.  
Force channel optimization when checked, attempts to place disks in the  
container on alternating physical SCSI channels, to maximize performance.  
13. In the Size options area, select Use all of … and then click Create, then OK.  
14. Read the Write Cache message:  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
This container’s write cache will be set to “Enable when protected”. However, because the  
container resides on a clustered controller’s shared channel the write cache will not be  
enabled.  
Click OK.  
15. At the Configure Spares screen click Continue. Later, a spare set can be created, if  
desired, and spares can be assigned to this container, but at this step, there are no drives  
available to select.  
NOTE  
For information about assigning spare disks in a cluster, refer to the HP NetRAID  
4M FAST Users Guide downloadable from the hp information library web site.  
16. Read the About Container Creation screen, then click OK.  
17. From the View menu, or by the icon, select the Container (Logical Drv) View option.  
18. Verify that the quorum container is initializing in the Container View screen.  
NOTE  
It is generally a good practice to wait for the initialization process to complete  
before continuing. The process will continue in the background after exiting  
FAST, as long as the operating system and services remain up, until 100% of the  
container is initialized.  
19. Exit the HP NetRAID-4M FAST utility.  
Create NTFS Partitions on shared storage  
20. From the Windows 2000 Start button open the Computer Management utility in the  
Administrative Tools menu.  
21. In the left panel, click on the Disk Management folder.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
22. Expand the view to see all disk space in the Disk Management screen. Right-click on the  
Unallocated Space representing the new container that appears in the window and select the  
Create a Partition option.  
23. Click Next at the Create a Partition wizard.  
24. Select the Primary partition option the click Next.  
25. Accept the Maximum space option and then click Next.  
NOTE  
Do not partition a disk into multiple partitions. Cluster Services software will only  
manage one partition per disk.  
26. Assign a drive letter. Oftentimes Q is used to designate the Quorum; then click Next.  
27. Select the NTFS format option and enter the volume name (e.g.: Quorum).  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
NOTE  
When formatting partitions for a container using the Disk Administrator or Disk  
Management utility, Quick Format is an option. The NetRAID-4M controller’s  
disk verify (with badblock repair) and container consistency check operations,  
which run in the background, will find (and repair) any bad blocks not detected  
during the quick format operation. (When the controller is busy, formatting  
partitions for a container can take a long time.)  
28. Click Next.  
29. Click Finish to complete the process and when the partition reports Healthy close the  
Computer Management window.  
CAUTION  
Do not shutdown or restart the server before completing the next step.  
Although Windows sees the container as a disk now, the NetRAID-4M will  
not allow access to the disk after a reboot, and it will not appear in the Disk  
Management window, unless a NetRAID-4M Diskset resource is associated  
with it.  
3.5 Create Shared Quorum Cluster Resource  
NOTE  
After you create a container, and partition it as a Windows disk, you must create a  
corresponding NetRAID-4M Diskset resource (using the MSCS Cluster  
Administrator utility) that maps to it. Then, that disk is capable of failing over  
according to the policies you establish for the cluster. For more information on  
working with NetRAID-4M Diskset resources, refer to the HP NetRAID 4M  
FAST Users Guide, listed in the Recommended Reading section of this document.  
1. From either server, open the Cluster Administrator utility, if not already open.  
2. In the left panel click once on the Groups folder.  
3. In the right panel, right-click on the Cluster Group.  
4. Select the New option then click on Resource.  
5. Enter the quorum name and then enter a Description (e.g.: Shared Disk Quorum).  
6. From the Resource Type drop list select NETRaid4M Diskset.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
7. For the Group name select Cluster Group and click Next.  
8. Change or confirm settings in the Possible Owners screen and then click Next.  
9. Make no changes in the Dependencies windows and click Next.  
10. Select the shared quorum diskset in the top box, as shown below, and then click Finish.  
11. Click OK to the success dialog box.  
12. Your Cluster Group should now appear as follows:  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
CAUTION  
The shared quorum SHOULD now be offline, and a red X appears next to  
Cluster Group.  
13. Right-click on the Quorum resource that is in an offline state. Select the Bring online  
option.  
14. If prompted with a message that a new device was found and to reboot the server, click  
NO.  
Assign the Shared Quorum to the cluster object  
15. In the left window panel, right-click the Clustername object.  
16. Click on the Properties tab and then click on the Quorum tab.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
17. From the Quorum Resource drop list, select the shared Quorumname item (the example is  
Cluster1) and then click OK.  
18. Click once on the Cluster Group in the left panel.  
Remove the Local Quorum Resource  
19. Right-click on the Local Quorum resource in the right panel and then select Take Off-  
line.  
20. After the Local Quorum shows Off-line status, right-click the Local Quorum resource and  
select the Delete option. Click Yes to confirm the deletion.  
21. The Cluster Group should now appear as shown:  
3.6 Test the Shared Quorum Failover  
1. In the Cluster Administrator left panel, click once on the Cluster Group and observe the  
current ownership of the individual resources.  
NOTE  
If not familiar with the default properties of the Cluster Group, right click the  
Cluster group and select Properties now. Note that by default, for example,  
Prevent Failback is checked. Properties extend to all resources within the group.  
Also, do not change the possible owners list of any resources within a group,  
without understanding that if any resource cannot failover in the group if the  
surviving node is not in its list of possible owners, then the group cannot fail over.  
2. Right-click the Cluster Group object in the left panel and select the Move Group option.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Cluster Software Components and Quorum  
3. Observe the ownership column of the Cluster Group resources in the right panel. The  
ownership should change to Server B.  
4. Move the Cluster Group back to Server A.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Creating Shared Disksets  
4 Expand Shared Storage for Cluster Services  
·
·
Create and initialize additional NetRAID-4M containers  
Create Windows partitions and NetRAID-4M Diskset Resources to be managed by  
Cluster Services  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Creating Shared Disksets  
4.1 Create Shared Disksets, Containers and NTFS Partitions  
1. On Server A, open the NetRAID-4M FAST utility and Open the NetRAID-4M controller  
connecting to shared storage.  
2. From the Disk (Physical Drv) menu select Manage Diskset.  
3. From the Non-Member Disks listing, select the Disk IDs to be included in the new array,  
then click the Create Diskset …>> button.  
4. Enter the Diskset name from 1 to 32 characters. (Example: Shared_S)  
5. Leave the options Attached and Re-initialize disk selected and then click OK.  
6. To create additional arrays, repeat steps 1 through 5.  
7. To assign a RAID type to an array, close the Manage Disksets window and from the  
Container (Logical Drv) menu select the Create Wizard option.  
8. Select a diskset.  
9. From the Type drop list, select a RAID type, in this example, that is:  
Mirror set (RAID 1)  
10. Select the Force in Dest checkboxes.  
11. Verify the entire drive will be used for this container and click Create, then OK.  
12. Click OK to the write cache message.  
13. Click Continue at the Configure Spare window and then click OK at the About Container  
Creation window if it appears.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Creating Shared Disksets  
14. In the FAST Container View console you should see the new logical containers as they are  
being initialized, as shown below:  
15. Wait for all disk initialization to complete before continuing.  
CAUTION  
DO NOT power off the server that the container initialization process was  
started from, until the initialization is complete.  
16. Open the Windows 2000 Disk Management utility to assign drive letters and format  
partitions.  
An example of a Disk Manager window showing formatted partitions:  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HP NetRAID-4M Cluster Services Installation Guide  
Creating Shared Disksets  
4.2 Create NetRAID-4M Diskset Resources for Data Drives  
1. From either server, open the Cluster Administrator utility  
2. In the left panel click once on the Groups folder.  
3. In the right panel, right-click on the Cluster Group.  
4. Select the New option then click on Resource.  
5. Enter the new shared data drive name, (e.g.: Shared_S)  
and then enter a description. (Example: Shared Data Drive S:)  
6. From the Resource Type drop list select NETRaid4M Diskset.  
7. For the Group name select Cluster Group and click Next.  
8. Change or confirm settings in the Possible Owners screen and then click Next.  
9. Make no changes in the Dependencies windows and click Next.  
10. Select the new data drive in the top box and then click Finish.  
13. Click OK to the success dialog box.  
14. Right-click on the resource that is in an offline state. Select the Bring online option.  
15. Create NETRaid4M Diskset resources for each new shared disk.  
NOTE  
Please refer to the HP NetRAID 4M FAST Users Guide, listed in the  
Recommended Reading section of this document, for instructions on configuring  
the myriad of cluster specific features available with the HP NetRAID-4M  
controller and NetRAID-4M Disksets.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Car Seat Car Seat Booster User Manual
Graco Yard Vacuum 253597 User Manual
Grizzly Saw DS300 AC User Manual
Haier Satellite TV System 29F9D User Manual
Harbor Freight Tools Carrying Case 41876 User Manual
Harbor Freight Tools Mobility Aid 96513 User Manual
Heath Zenith Door 598 1151 02 User Manual
Hotpoint Oven SY23 User Manual
Husqvarna Drill 225AI15 AI25 User Manual
i Tech Dynamic Headphones Clip S User Manual