MODEL H7826
Flooring Nailer
OWNER'S MANUAL
COPYRIGHT © OCTOBER, 2005 BY GRIZZLY INDUSTRIAL, INC. MAY, 2007 (TR)
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#EW7635 PRINTED IN CHINA
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Foreword
Contact Information
We are proud to offer the Grizzly Model
H7826 Flooring Nailer. This model is part
of a growing Grizzly family of fine pneu-
matic tools. When used according to the
guidelines set forth in this manual, you
can expect years of trouble-free, enjoyable
operation and proof of Grizzly’s commit-
ment to customer satisfaction.
If you have any comments regarding this
manual, please write to us at the following
address:
Grizzly Industrial, Inc.
C/O Technical Documentation
P.O. Box 2069
Bellingham, WA 98227-2069
It is our pleasure to provide this manual
with the Model H7826 Flooring Nailer. It
was written to encourage safety consid-
erations and guide you through general
operating procedures and maintenance.
Most importantly, we stand behind our
tools. If you have any service questions or
parts requests, please call or write us at
the location listed below.
Grizzly Industrial, Inc.
1203 Lycoming Mall Circle
Muncy, PA 17756
Phone: (570) 546-9663
Fax: (800) 438-5901
The specifications, details, and photo-
graphs in this manual represent the Model
H7826 as supplied when the manual was
prepared. However, owing to Grizzly’s pol-
icy of continuous improvement, changes
may be made at any time with no obliga-
tion on the part of Grizzly.
E-Mail: [email protected]
Machine Data
Nail Length .......................................11⁄2"-2"
Magazine Capacity...................... 100 Nails
Air Inlet ...........................................3⁄8" NPT
Flooring Nailer Weight...................111⁄3 lbs.
Hammer Weight...............................21⁄2 lbs.
Operating Pressure .................. 70-110 PSI
Read the manual before operation.
Become familiar with this tool, its
safety instructions, and its operation
before beginning any work. Serious
personal injury may result if safety or
operational information is not under-
stood or followed.
Model H7826 Flooring Nailer
-1-
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1: SAFETY
For Your Own Safety Read Instruction Manual
Before Operating This Equipment
The purpose of safety symbols is to attract your attention to possible hazard-
ous conditions. This manual uses a series of symbols and signal words which
are intended to convey the level of importance of the safety messages. The
progression of symbols is described below. Remember that safety messages by
themselves do not eliminate danger and are not a substitute for proper accident
prevention measures.
Indicates an imminently hazardous situation which, if
not avoided, WILL result in death or serious injury.
Indicates a potentially hazardous situation which, if
not avoided, COULD result in death or serious injury.
Indicates a potentially hazardous situation which, if
not avoided, MAY result in minor or moderate injury.
It may also be used to alert against unsafe practices.
This symbol is used to alert the user to useful infor-
NOTICE
mation about proper operation of the equipment.
Safety Instructions For Pneumatic Tools
5. KEEP CHILDREN AND VISITORS
AWAY. All children and visitors
should be kept at a safe distance
from work area.
1. KEEP ALL SAFETY DEVICES IN
PLACE and in working order.
2. REMOVE ADJUSTING KEYS AND
WRENCHES. Form habit of check-
ing to see that keys and adjusting
wrenches are removed from tool
before operation.
6. MAKE
WORKSHOP
CHILD
PROOF by locking your shop and
shutting off air valves.
7. DO NOT FORCE TOOL. It will do
the job better and safer at the rate
for which it was designed.
3. KEEP WORK AREA CLEAN.
Cluttered areas and benches invite
accidents.
8. USE THE RIGHT TOOL. Do not
force tool or attachment to do a job
for which it was not designed.
4. DO NOT USE IN DANGEROUS
ENVIRONMENT. Do not use pneu-
matic tools in damp or wet loca-
tions, or where any flammable or
noxious fumes may exist. Keep
work area well lighted.
9. DO NOT USE UNDER THE
INFLUENCE OF DRUGS OR
ALCOHOL.
-2-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Instructions For Pneumatic Tools
17. DISCONNECT TOOLS before ser-
vicing, changing accessories, or
moving to another location.
10. USE PROPER AIR HOSE for the
tool. Make sure your air hose is in
good condition and is long enough to
reach your work without stretching.
18. DO NOT OVERREACH. Keep
proper footing/balance at all times.
11. WEAR PROPER APPAREL. Do not
wear loose clothing, gloves, neck-
ties, rings, bracelets, or other jew-
elry which may get caught in moving
parts. Non-slip footwear is recom-
mended. Wear a protective hair cov-
ering to contain long hair.
19. USE
THE
RECOMMENDED
ACCESSORIES. Consult owner’s
manual for recommended acces-
sories. The use of improper acces-
sories may cause risk of injury.
20. CHECK FOR DAMAGED PARTS
BEFORE USING. Check for bind-
ing and alignment of parts, broken
parts, part mounting, loose bolts,
and any other conditions that may
affect machine operation. Repair or
replace damaged parts.
12. ALWAYS USE SAFETY GLASSES.
Also use a face or dust mask if cut-
ting operation is dusty. Everyday
eyeglasses only have impact resis-
tant lenses, they are NOT safety
glasses.
21. NEVER LEAVE UNATTENDED
TOOL CONNECTED TO AIR.
Disconnect the air hose and do not
leave tool until it is relieved of any
built up pressure.
13. WEAR APPROVED HEARING
PROTECTION. Air escaping from
pneumatic tools can exceed safe
exposure limits and may cause
hearing damage with prolonged
exposure.
22. NEVER ALLOW UNTRAINED
USERS TO USE THIS TOOL
WHILE UNSUPERVISED.
14. SECURE WORK. Use clamps or a
vise to hold work when practical. It is
safer than using your hand and frees
both hands to operate tool.
23. IF YOU ARE UNSURE OF THE
INTENDED OPERATION, STOP
USING TOOL. Seek formal training
or research books or magazines
that specialize in pneumatic tools.
15. MAINTAIN TOOLS WITH CARE.
Keep tools lubricated and clean
for best and safest performance.
Follow instructions for lubricating
and changing accessories.
24. BE AWARE OF HOSE LOCATION
WHEN
USING
PNEUMATIC
TOOLS. Hoses can easily become
a tripping hazard when laid across
the floor or spread out in a disorga-
nized fashion.
16. REDUCE
THE
RISK
OF
UNINTENTIONAL FIRING. Do not
carry tool with hand on trigger and
always disconnect from air when not
in use.
Model H7826 Flooring Nailer
-3-
Download from Www.Somanuals.com. All Manuals Search And Download.
Additional Safety Instructions for Nailers
1. HAND AND FOOT INJURIES: Do
not place your hands or feet near the
nail point of entry. A nail can deflect
and tear through the surface of the
workpiece, puncturing your hand or
foot.
7. NAILING: Avoid driving one nail on
top of another. The nail may deflect
and cause injury.
8. AIR SUPPLY: Disconnect the air
supply before installing nails, clearing
a jam, moving to another work area,
performing maintenance, or when the
tool is not in use. A nailer connected
to air may fire accidentally, causing
serious personal injury. DO NOT use
a check valve or any other fitting that
allows air to remain in the tool.
2. COMPRESSED AIR RATING: Do
not connect the nailer to compressed
air that exceeds 120 PSI.
3. ACTUATING MECHANISM: Be
careful not to bump the actuating
mechanism when carrying or hold-
ing the tool while connected to air.
If bumped, the tool may accidentally
shoot in a dangerous direction.
9. COMBUSTIBLE GASES: Never con-
nect the nailer to pressurized oxy-
gen or other combustible gases as
a power source. Only use regulated
compressed air.
4. SAFE HANDLING: Never point the
nailer at others! Carry the nailer only
by the handle, never by any other
part. Do not carry the nailer by the air
hose.
10. CLEANING: Never use gasoline or
other flammable liquids to clean the
nailer; vapors in the nailer will ignite
by a spark and cause it to explode.
5. HOSE USAGE: Make sure your air
hose is designed for the tool in use, is
in good condition, and is long enough
to reach your work without stretching.
However, an overly long air hose in
the work area may be a tripping haz-
ard.
11. TOOL SERVICE: If the nailer is leak-
ing air, damaged, or not working cor-
rectly, DO NOT use before repairing.
12. OPERATING QUESTIONS: If you
are not sure about the intended oper-
ation, stop using the nailer. Seek
formal training or research books or
magazines that specialize in pneu-
matic tools.
6. HAMMER SAFETY: DO NOT use a
hammer with a damaged handle or
a loose head. Make sure nobody is
standing close enough to be hit when
you swing the hammer.
-4-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
Nailer accidents routinely happen
while moving the gun to another loca-
tion, to another room, or even another
job site. Always disconnect the nail-
er immediately after use and never
transport the nailer while connected
to the air—even if the air compres-
sor is disconnected from its power
source!
Operating this nailer can pro-
pel objects into the air, causing
immediate eye damage. To protect
yourself, always wear American
National Standards Institute (ANSI)
approved safety glasses or goggles
when operating this equipment. In
addition, this nailer discharges at
up to 85-90 decibels. To protect
your hearing, always wear ANSI
approved ear protection when oper-
ating this nailer.
No list of safety guidelines can be
complete. Every shop environment
is different. Always consider safety
first, as it applies to your individu-
al working conditions. Use this and
other tools with caution and respect.
Failure to do so could result in seri-
ous personal injury, damage to equip-
ment or poor work results.
Model H7826 Flooring Nailer
-5-
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 2: SETUP
Unpacking
Inventory
Your Model H7826 left our warehouse in
a carefully packed box. If you discover
the nailer is damaged after you have
signed for delivery, please immediately
call Customer Service at (570) 546-9663
for advice.
After you open the nailer box, you should
find the following.
Model H7826 Inventory (Figure 1)
A. Flooring Nailer.................................... 1
B. Safety Goggles ................................. 1
C. Oil....................................................... 1
D. Base Plate.......................................... 1
E. Hammer ............................................. 1
F. Hex Wrench 4mm.............................. 1
G. Hex Wrench 5mm.............................. 1
Save the containers and all packing mate-
rials for possible inspection by the car-
rier or its agent. Otherwise, filing a freight
claim can be difficult.
When you are completely satisfied with
the condition of the shipment, you should
inventory the equipment.
A
B
E
C
F
D
G
Figure 1. Model H7826 inventory.
-6-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
Compressed Air
System
The Model H7826 is designed to be oper-
ated at 70-110 PSI using clean, dry, regu-
lated, compressed air. DO NOT exceed
the 120 PSI maximum operating pres-
sure for your model. Before using, regu-
late the air pressure on your air compres-
sor to 70 psi.
An in-line filter/lubricator/regulator unit,
depicted in Figure 2, can be installed and
should be located as close to the nailer
as possible.
Exceeding the maximum permissible
operating pressure may cause the
nailer to explode, blowing metal frag-
ments in all directions. To protect
yourself from serious personal injury,
DO NOT allow your air compressor to
exceed the recommended pressure
when connected to this nailer!
The filter/lubricator/regulator unit will pro-
tect your tool from damaging water build-
up, allow you to adjust and maintain
constant air pressure to your tool, and
save you the inconvenience of having to
manually lubricate your tool every time
you use it.
Quick
Connector
Quick
Connector
Lubricator
Regulator
Your
Tool
Air
Compressor
Quick
Coupler
Quick
Coupler
Air Hose
Filter
Figure 2. Typical filter/lubricator/regulator installation order.
Check the current Grizzly catalog for avail-
ability of this unit. If you plan on install-
ing a filter/lubricator/regulator unit in your
compressed air system, always follow the
connection instructions that come with
the unit.
Model H7826 Flooring Nailer
-7-
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Place the base of the nailer on a scrap
piece of wood that is clean and free
of any knots, nails, or other foreign
objects.
Firing Mechanism
The nailer should not fire when connected
to the air supply unless it is fired by hitting
the "whack cap" with the mallet. If the fir-
ing mechanism is not working properly,
the nailer could fire immediately when
connected to the air supply.
5. Hit the whack cap with the mallet using
moderate force. The nailer should fire.
— If it does fire, then the firing mecha-
nism is working properly. Continue
to the next section.
— If the does not fire, then the fir-
ing mechanism may not be work-
ing correctly or may need service.
Disconnect the nailer from the air
supply and please call (570) 546-
9663 for technical support.
Before you load your nailer for the first
time, check the firing mechanism to
ensure safe use.
To check the firing mechanism:
1. Make sure the nailer is disconnect-
ed from the air supply!
NOTICE
Continually firing the nailer when
empty will cause internal damage. Only
fire the empty nailer once or twice to
ensure it is functioning properly.
2. Make sure the magazine is empty and
contains no nails.
3. Place the flooring nailer on the ground
with the nail aperture facing down,
then connect the air hose. The nailer
should not fire.
— If it does not fire, read step 4.
— If the nailer does fire, immediately
disconnect the nailer from the air
supply and call (570) 546-9663 for
technical support.
Point the nailer at the ground when
connecting to the air supply. DO NOT
aim in the direction of another person
or a body part.
-8-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3: OPERATIONS
Oiling Nailer
Loading Nailer
Pneumatic oil has been included with this
Grizzly nailer to help maintain its useful
life. Place several drops of oil in the nailer
air inlet (as shown in Figure 3) before
every use and several times a day if used
continuously. Wipe off any excess oil near
the nailer exhaust to avoid dust build-up.
When the oil that was included with the
nailer has been completely used, replace
with Grizzly Model G2820 Pneumatic Tool
Oil.
When replacing nails in your Model
H7826, follow these guidelines:
Nails:
L-shaped cleat nails
Length: 11⁄2"–2"
Capacity: 100
Note: Use 11⁄2" nails to install 1⁄2" flooring.
Use 2" nails to install 3⁄4" flooring.
To load your nailer:
1. DISCONNECT NAILER FROM THE
AIR SUPPLY!
2. Slide a strip of nails, pointed-end
down, into the magazine as shown in
Figure 4.
Figure 3. Lubricating nailer via air inlet.
Another option to manual oiling would be
to install a lubricator, or a filter/lubricator/
regulator unit, in your air compressor line.
If your air compressor line already has a
lubricator, then regular lubrication of your
nailer will not be necessary. Just make
sure there is always pneumatic tool oil in
the lubricator.
Figure 4. Loading nails into nailer.
3. Push the button inside the pusher (inset
photo in Figure 4), pull the pusher all
the way back, then allow the pusher to
slide forward against the nail strip.
Model H7826 Flooring Nailer
-9-
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Place the nailer with the guide plate on
the flooring as shown in Figure 5, mak-
ing sure the cleat on the bottom of the
nailer is lined up with the edge of the
groove in the flooring.
Operating Nailer
Read the safety instructions in this
manual before operating the nailer.
Before you operate your nailer, place sev-
eral drops of the included oil into the quick
connect fitting where the nailer connects
to the air supply.
The Model H7826 comes with two base
plates of different thicknesses. The thin-
nest base plate is for use with 3⁄4" flooring,
and the thickest base plate is for use with
1
⁄
2" flooring.
Figure 5. Operating nailer.
To operate your nailer:
5. Using the rubber end of the included
hammer, hit the whack cap with light/
medium force to shoot a nail into the
wood. DO NOT use multiple strikes to
force the nail into the wood. This will
cause a jam or a ricochet, and possible
injury.
1. Install the correct base plate for your
size of flooring material.
2. Place the flooring nailer on the ground
with the nail aperture facing down,
then connect the air supply to the quick
connect fitting.
6. Check the nail for proper depth and
placement.
— If the depth is satisfactory, then pro-
ceed with your project.
— If the depth is too shallow, then
slightly increase the air pressure
and repeat Steps 3–5.
— If the depth is too deep, then slight-
ly decrease the air pressure and
repeat Steps 3–5.
Point the nailer at the ground when
connecting to the air supply. DO NOT
aim in the direction of another person
or a body part.
3. Position a flooring strip and tap it into
place with the metal side of the ham-
mer. DO NOT use the nailer to position
the flooring strips.
Note: Nailing depth is not always con-
sistent due to variations in the flooring
material. Sometimes it will be neces-
sary to tap a few nails flush with a ham-
mer and a nail punch.
Note: Test the nailer on a sample floor-
ing strip when installing pre finished
flooring to make sure the nailer does
not damage the finish. Replace the
base plate if it is damaged and marring
the flooring finish.
-10-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Remove the cap screws shown in
Figure 6 that secure the magazine.
Clearing Jammed
Nails
Figure 6. Cap screws securing the
magazine.
5. Remove the jammed nail (Figure 7)
with a pair of needle nose pliers, then
replace the magazine.
This nailer may accidentally fire if
you work on it without disconnecting
it from the air supply. Always discon-
nect air from nailer whenever clearing
a jammed nail!
A jammed nail must be cleared before
using the nailer again.
To clear a jammed nail from the dis-
charge area:
Figure 7. Jammed nail in discharge area.
1. DISCONNECT NAILER FROM THE
AIR SUPPLY!
6. Load a new nail stick that only contains
clean, undamaged nails. DO NOT use
dirty or damaged nails!
2. Pull the magazine loader all the way
back and remove the nail stick.
3. The jammed nail should now be vis-
ible; use needle nose pliers to remove
it from the discharge area.
—If the nail cannot be removed, con-
tinue to Step 4.
—Continue to Step 6, when the
jammed nail is removed.
Model H7826 Flooring Nailer
-11-
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 4: MAINTENANCE
Cleaning
Replacing Pistons/O-
Rings
DISCONNECT THE AIR SUPPLY! Use a
good solvent to clean the nose assembly
of the nailer. Always be sure that the nailer
is dry before using it again.
If you use your nailer day in and day
out, repair pistons are cheap insurance
against wasted down time and lost profits,
in the event that a piston or piston shaft
becomes worn out. Refer to the break-
down diagram in the back of the manual for
part numbers and ordering information.
Do not allow dust, chips, sand, etc. into
the air connectors or into the body of the
nailer; this may result in leaks and dam-
age to the nailer and the air couplings.
Disconnect air from nailer whenev-
er servicing! During maintenance, a
nailer connected to air may fire acci-
dentally, causing serious personal
injury!
To replace a piston:
1. DISCONNECT NAILER FROM THE
AIR SUPPLY!
2. Remove all nails from the magazine
cartridge and remove the base plate.
Never use gasoline or other flamma-
ble liquids to clean this tool. Vapors
in the tool may ignite, causing the
tool to explode. Ignoring this warning
may lead to serious personal injury or
even death!
3. Remove the cap screws shown in
Figure 8 that secure the base.
Figure 8. Removing the base.
-12-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Carefully slide the base off of the driver
and remove the large washer and rub-
ber bumper (see Figure 9).
7. Unscrew the cap screws and remove
the plunger (see Figure 11).
Bumper
Plunger
Washer
Figure 11. Removing the plunger.
Figure 9. Bumper and washer.
8. Grab onto the driver and pull the piston
assembly out from the bottom.
5. Use a flat head screwdriver to pry off
the whack cap shown in Figure 10.
9. Unscrew the piston and driver from the
piston assembly (see Figure 12).
Cylinder
Cover
Whack Cap
Piston Assembly
Exhaust Cover
Piston and
Driver
Figure 10. Removing the whack cap.
6. Loosen the exhaust covers and
remove the cap screws from the cylin-
der cover. Slide the cylinder cover off
of the plunger.
Figure 12. Piston and driver.
10. Apply a thin film of nailer lubricating oil
on the O-rings, then place the new O-
rings on the piston and the plunger.
11. Re-assemble the nailer in reverse
order.
Model H7826 Flooring Nailer
-13-
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Symptom
Possible Cause
Solution
Air leaking at
whack cap area.
1. Damaged seal.
2. O-rings on the plunger are
damaged.
1. Replace damaged seal.
2. O-rings must be replaced.
Air leaking between 1. Loose air fitting.
body and hose.
1. Tighten air fitting & use
teflon tape.
Air leaking around
driver.
1. Damaged O-ring on the pis-
1. Replace O-ring.
ton.
2. Worn bumper.
2. Replace bumper.
Nailer does not fire. 1. Nail is jammed in magazine
or discharge area.
1. Clear magazine or dis-
charge area.
2. Air pressure too low.
2. Check for blockage/
increase air pressure.
3. Place several drops of oil
in the air inlet.
3. Lack of lubrication.
4. Worn or damaged O-rings.
4. Replace O-rings. Make
sure air pressure does
not exceed the maximum
operating pressure.
5. Piston shaft is damaged.
5. Replace piston shaft.
Tool runs slowly
or has a loss of
power.
1. Air pressure too low.
1. Check for blockage/
increase air pressure.
2. Lubricate nailer.
2. Insufficient lubrication.
3. Dirt and oil buildup on driver. 3. Disassemble and clean
driver.
4. Exhaust port in cap is
blocked.
4. Clean exhaust port.
5. Worn or damaged O-rings.
5. Replace O-rings.
Tool skips nails
1. Air leaks.
1. See above.
while discharging.
2. Insufficient lubrication.
3. Dirt in nose.
2. Lubricate nailer.
3. Clean nose.
4. Dirt or damage prevents nails 4. Clean magazine and
from moving in magazine.
5. Inadequate air flow to tool.
inspect/repair damage.
5. Check for blockage/
increase air pressure.
6. Replace O-rings.
7. Replace bumper.
8. Replace pusher spring.
9. Use undamaged, correct
size, nails.
6. Worn or damaged O-rings.
7. Worn bumper.
8. Damaged pusher spring.
9. Bent, damaged, dirty, or
wrong size nails.
10. Damaged driver.
10. Replace driver.
Fasteners frequent- 1. Bent, damaged, dirty, or
1. Use undamaged, correct
size, nails.
ly jam the nailer.
wrong size nails.
2. Magazine screws are loose.
3. Driver or driver guide are
worn or damaged.
2. Tighten magazine.
3. Replace worn or damaged
parts.
-14-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
���
DESCRIPTION
���
���
���
���
���
���
���
���
REF PART #
REF PART #
DESCRIPTION
101 PH7826101 CYLINDER
102 PH7826102 HEAD GASKET
103 PH7826103 BUMPER
133 PH7826133 WHACK CAP
134 PW02M
FLAT WASHER 5MM
135 PH7826135 BRACE
136 PH7826136 RUBBER BRACE CASE
104 PH7826104 O-RING 50 X 3.55
105 PH7826105 DRIVER
137 PLN04M
138 PW01M
LOCK NUT M8-1.25
FLAT WASHER 8MM
106 PRP07M
107 PSS31M
ROLL PIN 6 X 20
SET SCREW M5-.8 X 8
139 PH7826139 L-BOLT
108 PH7826108 PISTON POLE
109 PH7826109 COMPRESSION SPRING
110 PH7826110 O-RING 12.8 X 2.5
111 PH7826111 O-RING 32 X 4.5
112 PH7826112 SEALING SLEEVE
113 PH7826113 O-RING 12.8 X 1.8
114 PH7826114 SEALING CAP
115 PH7826115 O-RING 15.6 X 1.8
116 PH7826116 GUN BODY
140 PH7826140 STOPPER
141 PS38M
PHLP HD SCR M4-.7 X 10
142 PH7826142 MAGAZINE SEAT
143 PH7826143 MAGAZINE END CAP
144 PLN01M
145 PH7826145 PUSHER SEAT
146 PRP42M ROLL PIN 3 X 20
LOCK NUT M4-.7
147 PH7826147 FLAT COIL SPRING
148 PH7826148 SPRING BUSHING
149 PH7826149 COMPRESSION SPRING
150 PH7826150 PUSHER
117 PH7826117 WASHER
118 PH7826118 END CAP
119 PSB39M
CAP SCREW M4-.7 X 20
151 PS07M
PHLP HD SCR M4-.7 X 8
120 PH7826120 BODY SEALING RING
121 PH7826121 BODY SEALING WASHER
122 PH7826122 CYLINDER GASKET
123 PH7826123 SLEEVE GASKET
124 PH7826124 O-RING 46.2 X 3.55
125 PH7826125 PISTON SEAT
152 PH7826152 MAGAZINE
153 PH7826153 NAIL HEAD
154 PH7826154 NAIL HEAD COVER BOARD
155 PH7826155 CYLINDER HEAD SEAT
156 PSB95M
CAP SCREW M5-.8 X 30
157 PH7826157 BASE PLATE
126 PLW02M
127 PSB16M
128 PS56M
LOCK WASHER 4MM
158 PSB95M
CAP SCREW M5-.8 X 30
CAP SCREW M4-.7 X 16
PHLP HD SCR M4-.7 X 16
159 PH7826159 RUBBER BOTTOM
160 PH7826160 BASE
161 PH7826161 WASHER
129 PH7826129 EXHAUST COVER
130 PH7826130 CYLINDER COVER
162 PFH03M
FLAT HD SCR M6-1 X 40
131 PSB53M
CAP SCREW M5-.8 X 18
163 PH7826163 MALLET
132 PH7826132 O-RING 25 X 3.55
164 PH7826164 1/4" NPT AIR PLUG
Model H7826 Flooring Nailer
-15-
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY AND RETURNS
Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original
purchaser from the date of purchase. This warranty does not apply to defects due directly
or indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of
maintenance. This is Grizzly’s sole written warranty and any and all warranties that may
be implied by law, including any merchantability or fitness, for any particular purpose, are
hereby limited to the duration of this written warranty. We do not warrant or represent that
the merchandise complies with the provisions of any law or acts unless the manufacturer so
warrants. In no event shall Grizzly’s liability under this warranty exceed the purchase price
paid for the product and any legal actions brought against Grizzly shall be tried in the State
of Washington, County of Whatcom.
We shall in no event be liable for death, injuries to persons or property or for incidental,
contingent, special, or consequential damages arising from the use of our products.
To take advantage of this warranty, contact us by mail or phone and give us all the details.
We will then issue you a “Return Authorization Number,” which must be clearly posted on
the outside as well as the inside of the carton. We will not accept any item back without this
number. Proof of purchase must accompany the merchandise.
The manufacturers reserve the right to change specifications at any time because they
constantly strive to achieve better quality equipment. We make every effort to ensure that
our products meet high quality and durability standards and we hope you never need to
use this warranty.
Please feel free to write or call us if you have any questions about the machine or the
manual.
Grizzly Industrial, Inc.
1203 Lycoming Mall Circle
Muncy, PA 17756
Phone: (570) 546-9663
Fax: (800) 438-5901
E-Mail:
Thank you again for your business and continued support. We hope to serve you again
soon!
-16-
Model H7826 Flooring Nailer
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY CARD
Name_________________________________________________________________
Street_________________________________________________________________
City _______________________ State_________________________ Zip _________
Phone #____________________ Email ________________________ Invoice #_____
Model # ____________________ Order #_______________________ Serial #______
The following information is given on a voluntary basis. It will be used for marketing purposes to
help us develop better products and services. All information is strictly confidential.
1. How did you learn about us?
____Advertisement
____Friend
____Catalog
____Card Deck
____Website
Other:________________________
2. Which of the following magazines do you subscribe to?
____ Cabinet Maker
____ Family Handyman
____ Hand Loader
____ Handy
____ Home Shop Machinist ____ Precision Shooter
____ Journal of Light Cont. ____ Projects in Metal
____ Popular Mechanics
____ Popular Science
____ Popular Woodworking ____ Wooden Boat
____ Practical Homeowner ____ Woodshop News
____ Today’s Homeowner
____ Wood
____ Woodsmith
____ Woodwork
____ Live Steam
____ Model Airplane News ____ Rifle
____ Modeltec
____ Old House Journal
____ RC Modeler
____ Woodworker West
____ Woodworker’s Journal
____ Other:
____ Shop Notes
____ Shotgun News
3. What is your annual household income?
____$20,000-$29,000
____$30,000-$39,000
____$40,000-$49,000
____$70,000+
____$50,000-$59,000
____$60,000-$69,000
4. What is your age group?
____20-29
____30-39
____60-69
____40-49
____70+
____50-59
5. How long have you been a woodworker/metalworker?
____0-2 Years ____2-8 Years ____8-20 Years
____20+ Years
6. How many of your machines or tools are Grizzly?
____0-2 ____3-5 ____6-9
____10+
____No
____No
7. Do you think your machine represents a good value? ____Yes
8. Would you recommend Grizzly Industrial to a friend? ____Yes
9. Would you allow us to use your name as a reference for our customers in your area?
Note: We never use names more than 3 times. ____Yes ____No
10. Comments:_________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
Download from Www.Somanuals.com. All Manuals Search And Download.
Send a Grizzly Catalog to a friend:
Name________________________________
Street________________________________
City______________State______Zip_______
FOLD ALONG DOTTED LINE
Place
Stamp
Here
GRIZZLY INDUSTRIAL, INC.
P.O. BOX 2069
BELLINGHAM, WA 98227-2069
TAPE ALONG EDGES--PLEASE DO NOT NAIL
Download from Www.Somanuals.com. All Manuals Search And Download.
|