Greenheck Fan Ventilation Hood 747680 User Manual

Document #474680  
Model SP  
®
Model CSP  
Ceiling Exhaust and Inline Fans  
Installation, Operation and Maintenance Manual  
Please read and save these instructions for future reference. Read carefully before attempting to assemble,  
install, operate or maintain the product described. Protect yourself and others by observing all safety  
information. Failure to comply with instructions could result in personal injury and/or property damage!  
Model SP  
Model CSP  
Model SP is a direct drive ceiling exhaust fan designed  
for clean air applications where low sound levels are  
required. Many options and accessories are available  
such as lights, motion detectors, ceiling radiation  
dampers and speed controls. Capacities range from 25  
Model CSP is a direct drive inline exhaust fan designed  
for clean air applications where low sound levels are  
required. Capacities range from 70 to 3,800 cfm (119 to  
6,456 m /hr) and 1 in. wg (248 Pa). AMCA Licensed for  
Air Performance.  
3
3
to 1,600 cfm (42 to 2,718 m /hr) and 1 in. wg (248 Pa).  
AMCA Licensed for Sound and Air Performance.  
ENERGY STAR® Certified models include:  
SP-A, 50, 70, 90, 200, 250, 290 and 410;  
SP-B, 50, 70, 80 and 90.  
WARNING!  
To reduce the risk of fire, electric shock, or injury to  
persons, observe the following:  
• Suitable for use with solid state speed controls.  
• Use this unit only in the manner intended by the manufacturer.  
If you have questions, contact the manufacturer.  
• Before servicing or cleaning unit, switch power off at service  
panel and lock service disconnecting means to prevent  
power from being switched on accidentally. When the service  
disconnecting means cannot be locked, securely fasten a  
prominent warning device, such as a tag, to the service panel.  
• Installation work and electrical wiring must be done by  
qualified person(s) in accordance with all applicable codes  
and standards, including fire-rated construction.  
• Sufficient air is needed for proper combustion and exhausting  
of gases through the flue (chimney) of fuel burning equipment  
to prevent back drafting. Follow the heating equipment  
manufacturer’s guideline and safety standards such as  
those published by the National Fire Protection Association  
(NFPA), and the American Society for Heating, Refrigeration  
and Air Conditioning Engineers (ASHRAE) and the local code  
authorities.  
• When cutting or drilling into wall or ceiling, do not damage  
electrical wiring or other hidden utilities.  
• Acceptable for use over a bathtub or shower when installed  
in a GFCI protected branch circuit. (Up through size SP-A390)  
• Never place a switch where it can be reached from a tub or  
shower.  
• Ducted fans must always be vented to the outdoors.  
• These fans are not recommended for cooking exhaust  
applications. They are designed primarily for low temperature,  
clean air applications only. The diagram shows the minimum  
distance these fans should be placed in relation to cooking  
equipment.  
• Fan/Light combination not to be installed in a ceiling thermally  
insulated to a value greater than R40.  
CAUTION!  
• For general ventilating use only. Do not use to exhaust  
hazardous or explosive materials and vapors.  
Ceiling Exhaust and Inline Fans  
1
®
Download from Www.Somanuals.com. All Manuals Search And Download.  
To mount the ceiling radiation damper to fan, make sure  
grille attachment tabs are facing down. Then place the inlet  
part of the fan into the ceiling radiation damper collar, and  
use self-tapping sheet metal screws (by others) to screw  
through the damper collar and into the fan housing. If the  
fan/light combination is being used, make sure ceiling  
radiation damper has  
Ceiling Radiation Damper (CRD)  
If fan is to be used in a fire resistive membrane  
ceiling, a ceiling radiation damper must be used.  
If the ceiling radiation damper is already mounted to  
the fan from the factory, proceed to Install the Fan.  
an electrical plug in it.  
The electrical plug must  
be inserted into the fan.  
Make sure the electrical  
wire will not interfere with  
damper operation as  
shown in figure below.  
Wires to ceiling fan  
Attachment Tabs  
Do not allow  
interference  
in this area  
Wires from lighted grille  
A-50-510, 710, 780 Models B-Models  
A-700, 900-1550 Models  
Discharge Installation SP-A 50-90 Models  
1
2
Insert plastic duct tab into SP-A box slots.  
Rotate plastic SP-A duct adapter (PN 473322)  
until the screw tabs meets SP-A box.  
Sheet Metal Screw #10x3/8  
Phillips Head (PN 415838)  
Sheet Metal Screw #10x3/8  
Phillips Head (PN 415838)  
SP-A Box  
SP-A Box  
SP-A Box Slot  
Screw Tabs  
Plastic SP-A  
Duct Adapter (PN 473322)  
Plastic SP-A  
Duct Adapter (PN 473322)  
Plastic SP-A  
Duct Adapter Tabs  
3
Install screws provided to secure discharge.  
Screw holes  
Sheet Metal Screw #10x3/8  
Phillips Head (PN 415838)  
Ceiling Exhaust and Inline Fans  
3
®
Download from Www.Somanuals.com. All Manuals Search And Download.  
Discharge Installation SP/CSP-B 50-200 Models  
1
2
Insert SP-B box scroll tab into SP-B box  
scroll slots.  
Rotate plastic SP-B duct adapter (PN 474433)  
until the two SP-B mounting tabs fully engage  
into the two SP-B box mounting slots.  
SP-B  
Box Scroll Tabs  
SP-B  
Box Mounting Slots  
SP-B  
Box Scroll Slots  
SP-B  
Box Mounting Tabs  
3
OPTIONAL  
Align the pins on the TR 6x4 adaptor to the  
duct pin hole on the SP-B 6-inch duct. Push  
until the adaptor snaps into place.  
TR 6x4 Pin  
SP-B  
Plastic Duct Pin Hole  
SP-B  
6-inch  
Plastic Duct  
(PN 474433)  
TR 6x4  
(PN 473324)  
Ceiling Exhaust and Inline Fans  
4
®
Download from Www.Somanuals.com. All Manuals Search And Download.  
For Frame Construction:  
Position unit between  
joists. Position brackets  
such that bottom  
edge of housing will  
be flush with finished  
ceiling, and tighten the  
adjustable mounting  
brackets, shown in  
Fig. 3.  
Install the Fan  
1. For best  
Slots in the  
brackets  
allow fine  
adjustment  
for flush  
performance,  
Do not install  
fan in this area  
choose a location  
with the shortest  
possible duct run  
and minimum  
number of elbows.  
Do not mount near  
cooking equipment, as  
shown in Fig. 1.  
fit with  
wall/ceiling  
opening  
45°  
45°  
Fig. 1  
Fig. 3  
Brackets can be  
used in either  
position to adapt to  
most mounting  
situations  
For Hanging  
Bottom Mount  
Bottom Mount  
Top Mount  
Installations:  
Use Greenheck’s  
optional vibration  
isolator kit Part Number  
VI Kit. Using the fan’s  
standard adjustable  
mounting brackets and  
10 by 32 threaded rod  
(by others), hang unit as  
shown in Fig. 4.  
2. Attach adjustable  
mounting brackets  
to fan, but leave the  
screws loose until  
proper height is  
Fig. 4  
determined, shown  
in Fig. 2. Cut hole to  
dimensions shown  
in table below:  
Fig. 2  
3. Installation of ductwork  
Fig. 5  
Ceiling Openings  
is critical to the performance  
of the fan, shown in Fig. 5.  
Straight ductwork (1) or  
ductwork that turns in  
the same direction as the  
wheel (2) is recommended.  
Ductwork turning opposite  
the wheel direction (3) will  
cause turbulence and back  
pressure resulting in poor  
performance.  
1
Sizes  
SP-A50, A70, A90  
Fan or Fan/Light  
107 x 133  
x 141  
Fan/CRD  
111 x 13716  
(GOOD)  
3
8
8
8
(POOR)  
2
SP-A110, A125, A190  
(GOOD)  
SP-A200, A250, A290, A390  
SP-A700  
121  
233  
8
4  
121  
241  
4
x 143  
x 121  
8
4
x 113  
x 183  
4  
8
4
SP-A410, A510, A710, A780  
143  
4  
8
147  
147  
143  
8
x 18716  
SP-A900, A1050, A1410,  
A1550  
143  
141  
4
x 24  
8
x 241  
x 121  
8
SP-B 50 - 200  
8
x 113  
4  
8
4  
NOTE  
4. Slide ductwork over the fan’s discharge collar and  
securely attach it with sheet metal screws.  
Model SP-A 50-90 are standard with a round duct.  
Should Model SP-A 110-190 require a round duct,  
Model RDC (Round Duct Connector) may be ordered  
from Greenheck for field installation.  
Make sure the screws do not interfere with damper  
operation. Check damper to make sure it opens freely.  
Wire the Fan  
1. Remove wiring cover.  
If fan/light combination  
is being used, make  
sure the fan plug is  
connected to the fan  
Fan  
Light  
receptacle and the light  
plug is connected to  
Fan Outlet (top)  
Fig. 7a  
Fig. 7b  
the light receptacle,  
shown in Fig. 6.  
Light Outlet (bottom)  
Fig. 6  
Using proper wire  
connectors, wire the fan as shown in Fig. 7a.  
For wiring of light proceed to Fig. 7b.  
220 - 240 Volt  
115 & 277 Volt  
Black wire is “Hot”  
Black wire is “Hot”  
White wire is “Neutral”  
Green wire is “Ground”  
White wire is “Hot”  
Green wire is “Neutral/Ground”  
2. Push all wiring into the unit’s cover and replace  
wiring cover.  
Ceiling Exhaust and Inline Fans  
5
®
Download from Www.Somanuals.com. All Manuals Search And Download.  
Attach the Grille  
Fig. 8  
1. If lighted grille is being used, plug wire into fan  
socket.  
If lighted grille and ceiling radiation damper are  
being used, plug wire from lighted grille into ceiling  
radiation damper socket. Do not plug wire directly  
into the fan socket. Make sure the wire does not  
interfere with the ceiling radiation damper operation.  
Fig. 9  
2. Attach grille with two screws provided. Make sure  
not to over tighten; over tightening will damage  
grille.  
3. Slide attachment screw covers over the attachment  
screws, shown in Figure 8 and 9.  
4. If lighted grille is being used, install light bulb(s) into  
light socket(s). For incandescent lights, use maximum  
100 watt bulb (by others). For fluorescent lights, use  
27W GU24 bulbs. Greenheck has replacement 27W  
GU24 bulbs call 1-800-355-5354 to order.  
Squeeze  
tabs to  
insert/remove lens  
5. If lighted grille is being used, snap lens into place, by  
pushing on the outside edges of lens, shown in Fig. 9.  
To remove lens, use small screw driver and pry on  
one side of lens.  
6. Turn on power and check fan and light operation.  
Converting from ceiling to cabinet design for Model SP fans  
All SP convertible sizes will be shipped with grille and duct collar cover.  
Conversion Kit Parts List  
• Qty. of 1 Blower Box Cover  
B
A
Tools Required  
• Phillips Head Screwdriver  
Step 1: Remove grille (A) by removing the two  
grille screws (B).  
Step 2: Remove duct collar cover (C) by  
removing the four duct collar screws (D).  
Step 3: Discard grille (A), two grille screws (B),  
and duct collar cover (C).  
C
D
Step 4: Remove the six (6) tinnerman clips (E)  
by twisting them to one side and pulling  
straight out. Discard two of the six  
tinnerman clips.  
F
E
D
Step 5: Insert the remaining four tinnerman clips  
(E) on grille opening side.  
Step 6: Place blower box cover (F) over  
tinnerman clips (E), which were inserted  
in step 5.  
Step 7: Screw the blower box cover (F) into place  
with four blower box cover screws (D).  
E
SP/CSP models shown are  
UL and cUL listed E 33599  
Ceiling Exhaust and Inline Fans  
6
®
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flex Duct  
Connections  
Other Installation Considerations  
Ductwork and Noise  
Fiberglass ductboard is a better choice than metal  
ductwork for reducing fan noise and is highly  
recommended for low sound applications. Where metal  
duct is used, sound transmission can be reduced with  
flexible duct connections between the fan and the duct.  
Sound and Location  
The location of these fans must be taken into  
consideration before installation. In critical sound  
installations, insulated ductwork, flexible duct  
connections or placing the fan in a remote section of  
ductwork are solutions to meeting the required fan sound  
levels.  
Remote  
Mounted  
CSP and SP-C  
Converted  
to Inline  
Filters  
The addition of an intake filter is highly recommended  
for these fans, even in clean air environments excess  
dirt can accumulate on wheels and motors causing  
reduced performance and imbalance.  
Fiberglass  
Ductboard  
SP and SP-C  
Mounted Directly  
Overhead  
Filters, once installed, should be checked and cleaned  
periodically to maintain performance.  
Greenheck offers washable aluminum mesh filters  
specifically designed for these fans. Please consult our  
SP/CSP catalog for more information.  
Correct Low  
Sound Installation  
Incorrect  
SP/CSP models shown are  
UL and cUL listed E 33599  
General Maintenance Suggestions  
Model SP/CSP ceiling exhaust fans require very little maintenance. But since small problems over time left  
unchecked could lead to loss of performance or early motor failure, we do recommend that the unit be inspected  
periodically (once or twice a year).  
The fan motor and wheel should be checked for dust and dirt accumulations. Dirt buildup can lead to loss of  
performance and motor overheating. Cleaning can be accomplished by brushing off any dust that may have  
accumulated. Even filtered units can accumulate build-up and should be checked when cleaning filters.  
The motor should be checked for lubrication at this time. Lubricate only those motors which have an oil hole  
provided. A few drops of all purpose oil (SAE 20) will be sufficient.  
Ceiling Exhaust and Inline Fans  
7
®
Download from Www.Somanuals.com. All Manuals Search And Download.  
Our Commitment  
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications  
without notice.  
Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the  
Library under Warranties.  
Greenheck SP and CSP catalog provides additional  
information describing the equipment, fan performance,  
available accessories, and specification data.  
AMCA Publication 410-96, Safety Practices for Users and  
Installers of Industrial and Commercial Fans, provides  
additional safety information. This publication can be  
®
474680 • SP/CSP, Rev. 1, March 2011  
Copyright 2011 © Greenheck Fan Corporation  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

Haier Drill 15F6B User Manual
Hamilton Beach Coffeemaker 48131 User Manual
Havis Shields Automobile Parts C TM EXC User Manual
Honeywell Thermostat EN2Z 0906GE51 R0708 User Manual
Hotpoint Washer HVL 241 User Manual
Hotpoint Washer HY6F 1551 User Manual
HP Hewlett Packard Fish Finder 5345A User Manual
Husqvarna Chainsaw EPA III User Manual
IBM Universal Remote Version 4 User Manual
Impex Home Gym EVE 540 User Manual