| SEFSDR-511   Combination Fire Smoke Dampers   Round Stainless Steel Blade   Application   UL 555S Leakage Class I   UL555 1 1/2 Hour Fire Resistance Rating   Model SEFSDR-511 is a severe environment 316SS combination fire   smoke damper with round style blade. The SEFSDR-511 has been   qualified to 3000 fpm (15.2 m/s) and 4 in. wg (1 kPa) for operation   and dynamic closure in emergency fire smoke situations. Model   SEFSDR-511 may be installed vertically (with blades running   horizontal) or horizontally and is rated for airflow and leakage in   either direction.   Model SEFSDR-511 meets the requirements for fire   dampers, smoke dampers and combination fire smoke   dampers established by:   National Fire Protection Association   NFPA Standards 80, 90A, 92A, 92B 101 & 105   IBC International Building Codes   New York City (MEA listing #260-91-M)   California State Fire Marshall   Ratings   UL 555 Fire Resistance Rating   Fire Rating: 1 1/2 Hour   Dynamic Closure Rating: Actual ratings are size dependant   Maximum Velocity: 3000 fpm (15.2 m/s)   Maximum Pressure: 4 in. wg (1 kPa)   Listing #: 3225-0981:112 (fire)   Listing #: 3230-0981:113 (smoke)   UL 555S Leakage Rating   “UL CLASSIFIED (see complete marking on   product)”   Leakage Class:   Operational Rating: Actual ratings are actuator dependant   Maximum Velocity: 3000 fpm (15.2 m/s)   I “UL CLASSIFIED to Canadian safety standards   (see complete marking on product)”   Standard 555 (Listing #R13317)   Maximum Pressure: 4 in. wg (1 kPa)   Maximum Temperature: 350º F (177°C) —Depending on actuator   Standard 555S (Listing #R13447)   Standard Construction   Frame/Sleeve: 20 ga. (1mm) 316 stainless steel integral   sleeve   Blade: Double skin 316 stainless steel (14 ga.   [2mm] equivalent) round style blade   Seal: Extruded silicone rubber blade seal   Axle: 1/2 in. (13mm) dia. 316 stainless steel   Bearing: 316 stainless steel sleeve type   Fusible Link: UL listed 165ºF (74ºC) -not 316SS   Size Limitations   Minimum Size: 6 in. (152mm) diameter   Maximum Size: 24 in. (610mm) diameter   Optional Features   • OCI (Open closed indication switches) -not 316SS   • 165ºF (74°C), 212ºF (100°C), and 350ºF (177°C) RRL - not 316SS.   • TOR (remote override of 165º F (74°C) closure allows damper to   perform smoke management functions during a fire emergency) -not   316SS.   D*   • Electric or pneumatic actuators to accomplish smoke management   and system functions.   * Dimensions furnished approximately 1/8 in. (3mm) undersize.   • One retainer plate required, additional retainer plate available   • 14 ga. (2mm) or 16 ga. (1.5mm) frame/sleeve   Nut   Opening + 2 in. Min.   Retaining   Plate Assembly   Clamping   Minimum Wall/Floor Opening   Screw   = Nominal Dia. + 7/8 in.   Clamping Screw   1.00 in. Min. Typ.   Fasteners   Download from Www.Somanuals.com. All Manuals Search And Download.   |