Instructions-Parts List
®
3T:1rRaationBuslldfoger Pump
306642F
- For use in lubrication applications only -
Model: 205028
With inductor, guide bars and release bar
Model: 205148, Series E
Without inductor, guide bars and release bar
300 psi (2.1 MPa, 21 bar) Maximum Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Use with lubrication applications only! This pump is
designed to be used for pumping non-corrosive and
non-abrasive lubricants and greases only. Any other use of
the pump can cause unsafe operating conditions and result
in component rupture, fire or explosion, which can cause
serious bodily injury.
Priming Piston Hazard
This pump has a priming piston which extends below the
foot valve during operation. This piston could pinch or
amputate your fingers or hands as it moves up, into the cyl-
inder. To reduce the risk of injury, keep your fingers and
hands and all tools away from the priming piston during
operation and whenever the air and fluid pressure in the
pump is not fully relieved.
ti10550a
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 1958, Graco Inc. is registered to I.S. EN ISO 9001
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
Grounding
(c)
(a)
In a low pressure air spray system, static sparking is
generally not a problem; however some simple precau-
tions should be taken to reduce the risk. Check your
local code for detailed grounding instructions for your
area and type of equipment. Ground all equipment.
Grounding reduces the risk of static and electric shock
by providing an escape wire for the electrical current
due to static build up or in the event of a short circuit.
(b)
(d)
•
plied). Loosen grounding lug locknut (a) and washer
(b). Insert one end of ground wire (c) into the slot in
the lug (d). Tighten locknut securely. Connect other
end of wire to a true earth ground.
FIG. 1
•
Air Compressor: according to manufacturer’s rec-
ommendations.
•
•
•
Object being sprayed: according to local code.
Fluid supply container: according to local code.
All solvent pails used when flushing: according to
local code.
Only use conductive, metal pails. Do not place the
pail on a non-conductive surface such as paper or
cardboard, which interrupts the grounding continu-
ity.
•
To maintain grounding continuity when flushing or
relieving pressure, always hold metal part of the dis-
penser firmly to the side of a grounded metal pail,
then squeeze trigger.
306642F
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
The typical installation shown in FIG. 2 is only provided as a guide for selecting and installing required and optional
accessories. Be sure all air and fluid accessories are properly sized for your system and are compatible with the fluid
you are pumping. Contact your Graco representative for assistance in designing a transfer system to suit your spe-
cific needs.
A
C
Air inlet
3/4 npsm(f)
swivel
B
E
D
F
Key:
A
B
C
D
E
F
Air Line Filter
Air Regulator
Air Runaway Valve
Air Line Oiler
Bleed-type Master Air Valve
Outlet Hose
2” npt
outlet
ti0551a
FIG. 2
•
•
•
3/4 in. ID Air Supply Line
3/4 npt(f) Air Inlet Swivel
On the Air Supply Line install:
•
Install Transfer Hose (F) to the 2 in. npt(f) pump
outlet and tighten securely.
For air requirements and additional Technical Data
•
Air Filter (A) to remove harmful dirt and mois-
ture from the compressed air supply
Install the Pump
•
•
Air Regulator (B) to control pump speed
1. Remove cover from a full, open head drum of lubri-
cant.
Air Runaway Valve (C) to stop the pump auto-
matically if the supply container is empty.
2. To help eliminate air pockets, which is essential for
good priming, smooth surface of the lubricant with a
straight edge until it is level.
•
Air Line Oiler (D) for automatic air motor lubri-
cation
•
Bleed-type master air valve (E): required in your
system to relieve air trapped between it and the air
motor when the valve is closed.
3. Lift pump from the inductor plate and wipe bottom of
plate clean.
4. Press inductor plate down onto the lubricant. Rock
plate back and forth to firmly seat it and to exhaust
air trapped under the plate. Continue with this
motion until some lubricant is forced up into the
neck of the inductor plate.
Never operate this pump with the bleed-type master air
valve (E) (supplied with the air motor) removed. When
closed, this valve relieves air trapped between it and
the air motor. Trapped air can cause the pump to cycle
unexpectedly and cause serious bodily injury from
moving parts.
5. Place pump on the inductor plate.
4
306642F
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Operation
Clearing Obstructions
Pressure Relief Procedure
The system pressure must be manually relieved to pre-
vent the system from starting accidentally, which could
cause moving parts to pinch or amputate your fingers.
To reduce the risk for injury, always follow this proce-
dure whenever you:
KEEP YOUR FINGERS AND HANDS AWAY FROM
THE PRIMING PISTON! The priming piston, located
at the pump intake, could pinch or amputate your fin-
gers as it moves into the intake cylinder.
•
•
are instructed to relieve the pressure
to clear any obstructions.
check or service any part of the pump or system.
2. Disconnect Air Hose. Grip 1-3/4 inch hex in the cen-
ter of the piston to unscrew it.
1. Shut off main air supply.
Removing Inductor Plate from Drum
2. Close the air regulator and bleed-type master air
valve.
Reference numbers and letters in parentheses in
3. Loosen a fluid fitting near the pump outlet to relieve
fluid pressure.
Startup
Reference numbers and letters in parentheses in
16
1. Turn on the main air supply.
2. Open Air Valve (E) and slowly open the Air Regula-
tor (B) until the pump is running smoothly. Always
use the lowest pressure necessary to deliver lubri-
cant at the desired quantity.
ti0552a
FIG. 3
CAUTION
Do not let the pump run dry. A dry pump quickly
speeds up and may damage itself. If the pump is run-
ning erratically or speeds up suddenly, relieve pump
pressure following Pressure Relief Procedure
Runaway Valve (D) to shut off the pump automatically
when the drum is empty.
2. Lift pump off inductor plate.
3. Insert the release bar (15) into the neck of the plate
and position it so that by applying leverage, the vac-
uum seal which formed beneath the plate, is broken.
4. Remove the plate.
when the pump is not in use.
306642F
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Troubleshooting
L
Problem
Cause
Solution
Pump doesn’t operate
Insufficient air supply
Be sure adequate volume of air is
supplied to pump. See Technical
Data on back cover.
Check for restriction in air line or
closed valves or regulators.
Check valve plate held closed by
obstruction
Follow the Pressure Relief Procedure
above. Remove pump from inductor
plate and clean pump intake.
Damaged air motor
See motor manual 307049, supplied.
Change drums.
Air motor operates but lubricant flow Empty lubricant drum
is low
Insufficient air supply
Increase air pressure. Do not exceed
100 psi (.7 MPa, 7 bar)
Erratic pump operation
Leakage from weep hole
Worn, damaged or obstructed check Follow the Pressure Relief Proce-
valve plate
inductor plate and clean and/or repair
intake.
Worn or damage throat packings
Replace v-packings and glands. See
page 7.
6
306642F
Download from Www.Somanuals.com. All Manuals Search And Download.
Repair
Repair
P
•
•
The throat packings are actually located in the
base of the air motor, but function as the throat
packings for the pump. To identify part numbers
and order repair parts, refer to parts list page
for air motor 208357 in instruction manual
307049, supplied.
B
C
Reference numbers and letters in parentheses
Parts List page 9.
E
Lips of
V-Packing
Must Face
Up
F
Weep
Hole
H
K
J
2. Disconnect air hose and transfer hose. Remove air
inlet fittings.
M
N
G
3. Remove pump from inductor plate (20).
L
D
17
Lips of
V-Packings
Must Face
Down
14
A
4. Unscrew priming piston (13) from connecting tube
(A). The priming piston has a 1-3/4 in. hex in the
center.
4, 2
19
13
FIG. 4
5. Remove nuts and lock washers (4, 2) holding pump
guides (12) and collars (17). Remove these parts.
6. Pull intake cylinder (19) straight down.
7. Remove screws (P) and air motor shield (B).
8. Remove screws and washers holding air motor cyl-
inder (C) to base (D). Pull base straight off, being
careful not to damage smooth surfaces of connect-
ing tube and cylinder.
9. Inspect v-packing (E) in base. If it is worn or dam-
aged, remove it. Grease new packing and carefully
tuck it into base. Be sure washer (F) is in place in
base.
10. Unscrew packing retainer (G) and remove the
spring and packings.
11. Clean all parts thoroughly and inspect for wear or
damage. Replace all packings and glads and other
parts as necessary.
12. Grease all parts thoroughly with light, waterproof
grease.
306642F
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Repair
13. One at a time, install a washer (H), bearing (J),
female gland (K), four leather v-packings (L) with
lips of the v-packings facing out of the base, male
gland (M), spring (N) and retainer (G).
14. Turn retainer in about 3 times.
15. Lubricate connecting tube (A) with light, waterproof
grease.
2. Disconnect air hose from motor.
3. Remove pump from inductor plate.
16. Carefully push base onto tube and secure it to the
cylinder with screws and washer. Then tighten pack-
ing retainer (G) snugly.
4. Remove nuts and lock washers (4, 2) holding pump
guides (12). Remove collars (17).
17. Inspect o-ring (18) in air motor base. Replace it if it
is damaged. Grease new o-ring before installing it.
5. Pull cylinder (19) straight down.
18. Install air motor shield and screws.
6. Unscrews priming piston (13) from connecting tube
(A). The priming piston has a 1-3/4 in. hex in the
center.
19. Install check valve plate (14), cylinder (19) collars
(17), and pump guides (12). Secure with lock wash-
ers (2) and nuts (4) on screws (5).
7. Remove check valve plate (14).
20. Screw priming piston (13) onto connecting tube (A).
8. Clean all parts thoroughly and inspect for wear or
damage. Replace parts as necessary and
reassemble.
8
306642F
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Parts
Model 205148
Pump, 3:1 Bulldog
3/4” npt air inlet
Ref.
No. Part No. Description
Qty.
2
4
5
8
10
11
13
14
17
18
19
21
100133 LOCKWASHER, spring, 3/8”
100340 NUT, hex; 3/8-16
100454 CAPSCREW, hex hd; 3/8-16x3”
101864 CAPSCREW, soc hd; 5/16-18 x 1”
162841 O-RING
4
4
4
4
1
1
1
1
2
1
1
1
162842 ADAPTER
162844 PLATE, priming shovel
162846 PLATE, check valve
162933 COLLAR, cylinder mounting
162934* O-RING
162936 CYLINDER, pump intake
208357 AIR MOTOR (see manual 307049
for parts)
21
8
2” npt(f)
fluid outlet
11
*
Recommended “tool box” spare parts. Keep on
hand.
1, 3
5
18
10
Model 205028
Pump, 3:1 Bulldog with inductor
Ref.
17
14
4, 2
19
No. Part No. Description
1
3
Qty.
12
100057 SCREW, hex hd cap; 5/16-18 x 3/4”
100214 LOCKWASHER, spring 5/16
4
4
13
6
9
12
15
16
20
100799 SCREW, rd hd mach; 1/4-20 x 1/2” 18
161288 SEGMENT, full barrel, 400 lb
162843 GUIDE, pump
6
4
1
1
1
16 Follow Plate Release Bar
162852* WIPER, follow plate
162853 BAR, follow plate release
205144 PLATE, follow
6
*
Recommended “tool box” spare parts. Keep on
hand.
9
15
20
ti10555a
FIG. 5
306642F
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Technical Data
Fluid Pressure Ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:1
Air Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 - 100 psi (0.28 - 0.7 MPa, 2.8 - 7 bar)
Maximum Working Fluid Pressure . . . . . . . . . . . . . . . . . . 300 psi (2.1 MPa, 21 bar)
Maximum Recommended Pump Speed . . . . . . . . . . . . . 60 cycles/minute
Air Motor Effective Diameter . . . . . . . . . . . . . . . . . . . . . . 7 in. (178 mm)
Stroke. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3/4 in. (120 mm)
Air Inlet Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npsm(f) swivel
Fluid Outlet Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 in. npt(f)
Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Priming Piston
Height. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28.25 in. (718 mm)
Inductor Diameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22.5 in. (570 mm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 lb (53 Kg) approximate
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum, steel, Buna-N, Leather, Brass, neoprene/duck
10
306642F
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
Notes
306642F
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Warranty and Disclaimers
Graco Warranty and Disclaimers
Warranty
Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and work-
manship on the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser’s sole
remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace
any part of the equipment proven defective. This warranty applies only when the equipment is installed, operated and
maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tamper-
ing, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused
by incompatibility with Graco equipment of structures, accessories, equipment or materials not supplied by Graco, or
improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or mate-
rials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco
distributor for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any
defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the
equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge,
which charges may include the costs of parts, labor and transportation.
Disclaimers and Limitations
The terms of this warranty constitute purchaser’s sole and exclusive remedy and are in lieu of any other warranties
(express or implied), including warranty of merchantability or warranty of fitness for a particular purpose, and of any
non-contractual liabilities, including product liabilities, based on negligence or strict liability. Every form of liability for
direct, special or consequential damages or loss is expressly excluded and denied. In no case shall Graco’s liability
exceed the amount of the purchase price. Any action for breach of warranty must be brought within two (2) years of
the date of sale.
Equipment Not Covered by Graco Warranty
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose,
with respect to accessories, equipment, materials, or components sold but not manufactured by Graco. These items
sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.) are subject to the warranty, if any,
of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of
these warranties.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 306642
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
12/1958, Revised 6/2007
12
306642F
Download from Www.Somanuals.com. All Manuals Search And Download.
|