Instructions–Parts List
306522F
Air Operated Pump Elevator
EN
To raise or lower a pump; 120 lb (54 kg) exposed drum size.
For professional use only.
100 psi (7 bar, .7 MPa) Maximum Working Pressure
60 lb (27 kg) Maximum Lift Weight
Model 204121, Series A
Bare elevator
Model 204124
Includes bare elevator, drum cover, and cover bracket
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
06543b
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Locating the Elevator (Fig. 1)
1. Provide sufficient clearance in front of the elevator
to change drums.
2. The ceiling must be at least 6 ft. (1.8 m) high for
the elevator to be fully raised.
114
108
3. Be sure the air supply lines to the pump and
elevator and the fluid outlet line from the pump can
be brought to the site. Use several feet of hose
between the pump and its supply lines to allow the
pump to be raised and lowered.
207
202,
203
204
Installing the Elevator (Fig. 1)
Raised
71in.
(1803 mm)
1. Use 3/8 in. size bolts (A) which are long enough to
firmly secure the elevator base (110) to the con-
crete floor. Use shims as necessary to level the
base. Ensure that the elevator tube is in a true
vertical position.
111
2. Position a 120 lb lubricant drum so that it is touch-
ing the elevator base (110).
Lowered
41.75 in.
3. Loosen the screws (202) and nuts (203) on the
bracket (204). Position the drum cover (207)
squarely on the drum bead. Lightly tighten the
screws and nuts.
(1060 mm)
0.25 in.
(6 mm)
Mounting the Pump
110
R
R
1. Mount a Fire-Ball or Fast-Flo pump on the
bracket.
A
2. Refer to your separate pump instruction manual for
further information on system accessories and
installation.
06543b
Fig. 1
306522
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
304
303
WARNING
To reduce the risk of serious injury, including pinch-
ing or amputating your fingers, or splashing fluid in
the eyes or on the skin, always follow these pre-
cautions when using the elevator.
301
115
302
117
116
1. Relieve the air and the fluid pressure in the
pump before raising the pump to prevent
unexpected cycling of the pump.
108
2. Keep your fingers away from the top of the
drum and the bottom of the drum cover when
lowering the pump into the drum. Grasp the
pump bracket or pump motor when guiding the
pump into the drum.
06545b
Fig. 2
2. Leave the air line connected to the elevator while it
is in the raised position.
3. Position a drum against the base of the elevator.
3. Never use the elevator to lift a pump which
weighs more than 100 lb (45 kg). The elevator
may not be able to hold up a heavier pump,
and the pump could drop unexpectedly, caus-
ing personal injury as well as property damage.
4. Disconnect the air line coupler; the pump will
lower. Check and adjust the elevator speed, if
necessary. See the section to the left.
5. As the pump is lowered, place your hands on top
of the drum cover or on the pump air motor to
guide the pump into the drum.
4. Keep the restrictor valve in the restricted
position to avoid excessive speed when raising
the elevator.
Changing Drums
Adjusting the Elevator Speed
1. Shut off the air supply to the pump and relieve all
air and fluid pressure.
Before regular operation of the elevator, check the
elevator speed.
2. Raise the pump, leaving the air line connected,
and change drums.
1. Loosen the locknut (301) of the restrictor
valve (114) located at the top of the elevator. Turn
the adjusting needle (304) fully clockwise to de-
crease speed. See Fig. 2.
Shutdown
1. Never leave the elevator in the raised position
when not in use. Shut off the air supply to lower
the elevator.
2. Connect the air line to the elevator pin fitting.
Slowly turn the adjusting needle (304) counter-
clockwise to raise the pump. When adequate
speed is obtained, tighten the locknut (301).
2. For overnight shutdown or longer, and before
servicing the elevator, pump, or any system com-
ponents, disconnect the air line coupler from the
elevator pin fitting. Relieve all air and fluid pressure
in the pump and system.
Raising and Lowering the Pump
1. With the elevator speed adjusted, connect the air
line coupler to the elevator pin fitting (108). The
pump will rise. See page 3.
3. If possible, keep the pump submerged in lubricant
to avoid contaminating the system. If that is not
possible, lower the pump into a clean, empty drum.
4
306522
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
Lubrication (Fig. 3)
114
115
Every two or three weeks follow this procedure to keep
the elevator operating smoothly.
117
116
108
1. Disconnect the elevator air line, relieve all air and
fluid pressure in the pump and system.
112
2. With the elevator in the down position, unscrew the
cap (112). Fill the inner cavity of the leather cup
packing (106) with SAE 20 oil. Replace the cap.
106
3. Raise the elevator and lubricate the exposed
surface of the guide tube (104).
104
06544b
Fig. 3
306522
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Model 204124
Elevator Cover and Bracket
Includes items 1 and 2
Ref No. 114, 203743
Restrictor Valve Assembly
Includes items 301 to 304
Ref No. 1, 204121
Elevator
Includes items 101 to 117
Ref No. 2, 204123
Drum Cover and Bracket
Includes items 201 to 207
301
304
302
115
116
108
303
117
112
107
111
202
201
203
101
106
205
105
113
204
207
206
109
104
110
06542b
6
306522
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Model 204124
Ref No. 114, 203743
Pump Elevator, Cover, and Bracket
Includes items 1 and 2
Restrictor Valve Assembly
Includes items 301 to 304
Ref.
No.
Ref.
No.
Part No.
Description
Qty.
Part No.
Description
Qty.
1
204121
ELEVATOR
301
302
303
304
101448
157628
160162
160163
LOCKNUT, jam 3/8–24
PACKING, o-ring
HOUSING, valve
NEEDLE
1
1
1
1
See separate parts list
DRUM COVER & BRACKET
See separate parts list
1
1
2
204123
Ref No. 1, 204121
Elevator
Includes items 101 to 104
Ref No. 2, 204123
Drum Cover & Bracket
Includes items 201 to 207
Ref.
No.
Ref.
No.
Part No.
Description
Qty.
Part No.
Description
Qty.
101
104
105
106*
107
108
109
110
111
112
113
114
100155
154625
154628
154629
154632
169969
157761
160850
160851
160852
160856
203743
NUT, hex, jam; 5/8–18
TUBE, inside elevator guide
WASHER
PACKING, leather cup
GASKET
FITTING, air line
TUBE, elevator stop
BASE, 120 lb. elevator
TUBE, elevator riser
CAP, elevator riser tube
BODY, elevator bracket
RESTRICTOR VALVE ASSEMBLY
See separate parts list
ADAPTER; 1/4 npt(f) x 1/8 npt(m)
BUSHING; 1/4 npt(m) x 1/8 npt(f)
ADAPTER; 1/8 npt(f) x 1/8 npt(m)
1
1
1
1
1
1
1
1
1
1
1
201
202
160854
100022
CLAMP, elevator bracket
CAPSCREW, hex hd
1
1/4–20 x 3/4”
NUT, sq, mach; 1/4–20
BRACKET, elevator
SCREW, mach, flat hd; 1/4–20 x 1”
GASKET, rubber; 40 in. (1016 mm)
COVER, drum, 10 gal
4
4
1
2
1
1
203
204
205
206
207
100677
160853
109469
070148
204126
1
1
1
1
115
116
117
159840
100030
16T421
* Recommended tool box spare part. Keep on hand to reduce
down time
306522
7
Download from Www.Somanuals.com. All Manuals Search And Download.
The Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited
warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment
determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accor-
dance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais-
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Information
patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the distributor closest to you:
Phone: 612–623–6921 or Toll Free: 1–800–328–0211 Fax: 612–378–3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 306522
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES S P.O. BOX 1441 S MINNEAPOLIS, MN 55440–1441 S USA
Copyright 2002, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Revised August 2013
8
306522