Instructions - Parts List
GTP10 Herbicide
Pump
311628C
ENG
For pumping herbicides. Do not use to pump other fluids including water.
Model 260410, 10 gpm (38 lpm), 12 VDC (CSA C/US listed motor)
Model 260411, 10 gpm (38 lpm), 12 VDC (CSA C/US listed motor)
Includes 8 ft (2.44 m) hose, nozzle and inlet suction tube
Model 260408, 12 gpm (45 lpm), 115 VAC
Model 260409, 12 gpm (45 lpm), 115 VAC
Includes 8 ft (2.44 m) hose, nozzle and inlet suction tube
10 psi (0.07 MPa, 0.7 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
CSA mark applies only to 12 VDC motors
for Class I, Div I, Group D Hazardous
Locations.
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS forms from distributor or retailer.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco
replacement parts only.
•
•
•
•
•
•
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your Graco distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe
burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.
311628C
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
suction tube assembly (5c) and screw the suction
tube into the pump inlet (1j).
5. Insert suction tube attached to pump through bung
adapter (9) into tank. Position pump as desired and
tighten union nut (1k) on bung adapter (9).
When unpacking pump, check for shipping damage.
Report any shipping damage to delivering carrier imme-
diately.
Mounting Hose and Nozzle
CAUTION
1. Apply herbicide compatible sealant to male threads
on the street elbow fitting (1e) and screw fitting into
the 3/4 in. npt outlet port on the top of pump. Do not
over tighten.
Do not use a curb pump automatic shut-off nozzle
with this pump. Use of a curb pump automatic nozzle
may cause priming problems, reduced output flow,
and motor overheating. If an automatic shut-off nozzle
is required, use Graco part number 260082 (regular)
or 260083 (unleaded) or Catlow, Inc. part number
NCLF-1 (regular) or NCNLF-1 (unleaded).
2. Apply herbicide compatible sealant to threads on
both ends of the hose assembly. Screw one end of
hose into the female thread on the fitting (1e) and
tighten.
Mounting Pump
3. Screw nozzle onto the other end of hose and
tighten.
CAUTION
•
•
Ensure tank being used is clean and free of welding
slag.
Ensure the tank has a vent to allow air into the tank
as the herbicide is being pumped out. Failure to
vent tank will cause priming problems.
Electrical Installation
12 VDC
To install wiring for a negative ground system:
1. Apply herbicide compatible sealant to large thread
on bung adapter (9) (2 in. x 1-1/2 in. reducer fitting).
Install bung adapter on tank.
1. Ensure pump switch is OFF.
2. To remove electrical cover (2a), remove four bolts
(2c).
2. Assemble suction tube sections by applying PVC
cement (supplied with your pump) to the inside
diameter of the PVC couplers. Make sure PVC
cement is applied to the complete inside diameter
and slide the pipe sections into the coupler with a
twisting motion.
Power cable can be cut to shorter length if 18 feet
(5.5 m) is not required. Cut to proper length and
proceed with steps 3 and 4.
3. Strip 3 in. (76 mm) of outside insulation from power
cable (6c) from end opposite of fuse.
For tanks deeper than 36 in. (914 mm) you will
need a standard 1 in. (25 mm) pipe with 1 in. npt
threads on one end. Suction tubes longer than 60
in. (1.52 m) require a foot valve (Graco Part No.
260217) at the bottom of the tube to prevent loss of
prime.
4. Strip 3/8 in. (10 mm) of insulation from red and black
wires.
5. Slide strain relief (6b) over end of power cable (6c)
on the end just stripped. Male thread of strain relief
should be toward stripped end.
3. Cut the suction tube so that it is 2 in. (55 mm) from
the bottom of the tank when installed in the tank.
6. Insert power cable through conduit thread in electri-
cal cover (2a). Connect wires from power cable to
wires from the motor using wire nuts (2e): red to red
and black to black.
4. Insert inlet gasket (7) into union nut (1k). Apply a
herbicide compatible sealant to the threads on the
4
311628C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
7. Screw strain relief (6b) into electrical cover (2a).
6. Insert electrical power wire through conduit opening
in back of pump.
8. Position power cable (6c) so the large diameter of
power cable extends through strain relief (6b).
7. Using wire nuts (2e), connect wires: green to green,
white to white, and black to black.
9. Tighten nut on strain relief to form a seal around the
power cable.
8. Replace electrical cover.
10. Reinstall electrical cover (2a) on the pump.
Priming Pump
11. Remove 1/2 in. (13 mm) of insulation from wires on
the fuse holder end of the power cable.
1. All pump models will prime with no fluid in the
pumping chamber to a height of 5 ft (1.52 m). If
pump fails to prime, remove hose from street elbow
fitting on pump outlet and pour 8 oz (0.24 liter) of
motor oil into the pump outlet port.
12. Attach battery clamps (6a) with red sleeve to red
wire and black sleeve to black wire. Wire must be
crimped to the battery clamp firmly to get a good
electrical connection.
2. If suction height is too great, the pump may lose its
prime if the nozzle is opened with the pump turned
off.
13. Connect red wire with fuse holder inline to positive
battery terminal. Connect black wire to negative bat-
tery terminal.
3. To hold fluid in the suction tube, a check valve
(Graco Part No. 260217) may be required on the
bottom of tanks with a suction height over 5 ft (1.52
m).
Electrical Installation
115 VAC
4. The tank must be vented or the pump may not prime
or may lose its prime due to a vacuum in the tank.
On 115 VAC pumps, electrical connections must be
made by a licensed electrician per requirements of
local, state, and national codes regarding class 1,
group D installations. Only rigid conduit with
threaded connections should be used. Conduit
opening in pump must be sealed with waterproof,
herbicide-resistant sealant. Failure to comply with
this warning could result in injury from electrical
shock.
1. Ensure pump switch is OFF and electrical power is
disconnected.
2. Install conduit and user-supplied power cord to
pump.
3. Strip 3 in. (76 mm) from power cord jacket and 1/2
in. (13 mm) from individual conductor insulation.
4. To remove electrical cover (2a), remove four bolts
(2c).
5. Remove 1/2 in. (13 mm) of insulation from power
wires inside pump electrical terminal cavity.
311628C
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Operation
Maintenance
1. Clean inlet strainer (3b) after every 50 hours of
operation.
Before servicing, turn pump off and open the
nozzle to relieve pressure.
2. To remove inlet strainer (3b), remove four screws
(3c) and strainer cover (3a). Remove and clean
strainer.
CAUTION
Do not operate pump dry. Do not run pump for more
than 5 minutes with nozzle closed. Do not operate
pump for more than 30 minutes continuously in 1 hour.
3. If strainer is excessively dirty, clean tank to protect
pump and the equipment.
4. After cleaning strainer, replace strainer and cover.
Make sure cover seal (3d) is in place.
On/Off switch lever (8d) is located under nozzle holder.
Remove nozzle before turning pump on.
Flushing Pump
1. Move switch lever (8d) on.
Proper flushing of pump after use with herbicides and
chemicals is essential for long service life. Many herbi-
cides dry quickly and will make pump inoperative if
allowed to dry inside pump.
2. Insert nozzle into tank and actuate nozzle lever to
dispense herbicide.
3. Immediately after dispensing herbicide turn switch
lever (8d) off.
CAUTION
All fluids pumped must be compatible with wetted
1. Remove pump from tank and insert suction tube into
water or chemical agent recommended by chemical
manufacturer.
2. Operate pump until fluid discharge is free of chemi-
cal.
3. For extended storage after use with herbicide or
chemical, flush pump and fill with diesel fuel.
6
311628C
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
311628C
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Troubleshooting
Problem
Cause
Solution
Motor runs but pump will not prime. Motor rotation wrong. (12 VDC units Check wiring instructions for possible
only.) problems.
Missing relief valve o-ring seal (4c). Remove gear cover (1b) inspect seal
(4c), replace if missing or damaged.
Sheared drive key (1g).
Remove cover (1b) and inspect key
(1g/10b), replace if worn or sheared.
Dirt under relief poppet (4a) or seal
(4c).
Remove cover (1b) and inspect,
clean or replace if damaged.
Strainer seal (3d) leaking.
Suction height too high to prime.
Worn or damaged gears.
Inspect and replace if damaged.
Remove cover (1b) and inspect
gears. Replace if worn or damaged.
Fluid level low.
Refill tank.
Cover seal (1f/10c) damaged.
Inlet strainer (3b) clogged.
Air leak in suction tube.
Replace if worn or damaged.
Remove and clean or replace.
Inspect all joints in suction tube,
make sure all joints have sealant
applied.
Air lock in system.
This may occur if filter or meter or
automatic shut-off nozzle is used. If
this occurs, fill pump and meter with
herbicide through top of pump.
Motor does not run at proper speed. Check electric connections. Check
supply voltage for proper voltage
level.
Unit pumps but output flow is low.
Clogged inlet strainer (3b).
Air leak in suction tube.
Clean or replace.
Check to make sure all joints in suc-
tion tube are sealed.
Suction tube too close to tank
bottom.
Suction tube must have a 2 in.
(51 mm) minimum clearance.
Tank empty.
Refill tank.
Tank not vented.
Worn or damaged gears.
Tank must be vented to atmosphere.
Remove cover (1b) and inspect
gears. Replace if worn or damaged.
Damaged motor.
Replace motor.
Clogged suction tube, hose, or
nozzle.
Inspect and clean.
Motor stalls when nozzle is closed.
Bypass relief valve (4a) stuck.
Inspect relief valve, making sure
poppet is free. Replace if damaged.
Low supply voltage.
Check supply voltage.
Gears (1c/10a) damaged and
binding.
Inspect gears. Gears should turn
freely. Replace if damaged.
Faulty motor.
Replace motor.
8
311628C
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Problem
Cause
Solution
Herbicide leaking in motor mount.
Faulty or damaged motor shaft seal Replace shaft seal
(1h).
Operating pump extended time with Do not exceed 5 minutes of operation
nozzle closed.
with nozzle closed.
Motor shaft worn.
Replace motor if shaft has groove
worn in seal area.
Motor overheating.
Gears (1c/10a) binding.
Check to make sure gears turn freely
on shaft.
Operating pump extended time with Do not exceed 5 minutes of operation
nozzle closed.
with nozzle closed.
Clogged inlet strainer (3b).
Clean or replace, see Maintenance,
page 6.
Clogged suction tube, hose, or
nozzle.
Inspect and clean if required.
Operating pump more than 30 min-
utes continuous duty.
Limit operation to 30 minutes per
hour.
Switch will not turn pump on.
Blown fuse.
Replace fuse. 20 amp automotive
fuse (Littelfuse ATO 257020 or
Bussman ATC-20).
Electrical problem.
Check that supply voltage is proper
and getting to pump.
Defective switch (8e).
Mechanical problem.
Check and replace if defective.
Check switch actuator cam (8c). Cam
should be actuating the switch (8e).
Damaged or defective motor.
Check motor, replace if damaged or
defective.
311628C
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts Drawing
Parts Drawing
Models 260410 and 260411, 12 VDC
Models 260408 and 260409, 115 VAC
3c
3d
260456
3a
1i
3b
260458
253723
1b
1f/10c
1g/10b
1c/ 10a
1d
7
1j
4c
9
4b
260544
4a
4d
1h
1a
1k
2g
2h
2i
5c
5a
2c
2b
2d
2e
2f
260300
5b
5a
260450
260452
253719
253721
8e
8f
8b
8g
8c
260433
253718
2a
6a
8a
2c
6b
6c
260454
8d
10
311628C
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts List
Parts List
Models 260410 and 260411, 12 VDC
Models 260408 and 260409, 115 VAC
Ref. No.
Description
Qty.
Ref. No.
Description
Qty.
5
260300 KIT, suction, pipe; includes items
1
260458 KIT, pump with swivel, blue
(includes items 1a-1k)
5a-5d (Models 260411, 260409 only)
PIPE, PVC
COUPLER, PVC, female
ADAPTER, PVC, male
CEMENT, PVC (not shown)
5a
5b
5c
5d
2
1
1
1
253723 KIT, pump with swivel, black
(includes items 1a-1k)
1a
1b
1c (10a) GEAR
1d
1e
BODY, assembly
COVER, gear
1
1
2
2
1
6* 260454 KIT, cable, 12 V
(includes items 6a-6c)
CLAMP, battery
SHAFT, gear
FITTING, outlet, 3/4 in. npt, street
elbow (not shown)
6a
2
1
1
1
1
BLACK SLEEVE
RED SLEEVE
STRAIN RELIEF
ASSEMBLY, power cable,
18 ft (5.5 m), fuse holder, 20 amp
fuse
1f (10c) SEAL, gear cover
1g (10b) KEY, drive
1h
1i
1
1
1
4
1
1
6b
6c
SEAL, shaft
BOLT, hex, 5/16-18 x 3/4 in.
FITTING, inlet
1j
7
8
260084 GASKET, inlet
260433 KIT, switch, blue
1
1k
NUT, union
2
260450 KIT, motor, 12 VDC, blue
(includes items 2a-2i)
(includes items 8a-8g)
253718 KIT, switch, black
(includes items 8a-8g)
260452 KIT, motor, 115 VAC, blue
(includes items 2a-2i)
253719 KIT, motor, 12 VDC, black
(includes items 2a-2i)
253721 KIT, motor, 115 VAC, black
(includes items 2a-2i)
2a
2b
2c
2d
2e
8a
8b
8c
8d
8e
8f
COVER, switch
BRACKET, switch
CAM, actuator switch
SWITCH, actuator assy.
SWITCH
SCREW, phillips, 8-32 x 3/8 in.
SCREW, phillips, 6-32 x 1/4 in.
1
1
1
1
1
2
1
1
COVER, electrical
HOUSING, electrical, 12 V
BOLT, hex, 1/4-20 x 3/4 in.
NUT, 10-32
WIRE NUT, 260450
WIRE NUT, 260452
FLAG TERMINAL
MOTOR, electric
1
1
10
2
2
3
2
1
1
1
8g
9
260061 ADAPTER, bung
10 260277 KIT, gear (includes 10a-10c)
10a (1c) GEAR
2
1
1
10b (1g) KEY, drive
2f
10c (1f) SEAL, gear, cover
11 260310 HOSE, 8 ft, 3/4 in. (MBE),
(Models 260411, 260409 only)
(not shown)
12 260079 NOZZLE, 3/4 npt (f),
(Models 260411, 260409 only)
(not shown)
2g
2h
2i
COVER, nozzle
GUIDE, nozzle
3
4
260456 KIT, filter, universal
(includes items 3a-3d)
3a
3b
3c
3d
COVER, strainer
SCREEN
SCREW, hex head, 10-24 x 3/8 in.
SEAL, strainer cover
1
1
4
1
13▲15G901 LABEL, warning (not shown)
260544 KIT, popoff (includes items 4a-4d)
▲ Replacement Danger and Warning labels, tags, and
4a
4b
4c
4d
POPPET, relief valve
SPRING, relief valve
SEAL, relief valve
RING, retaining
1
1
1
1
cards are available at no cost.
* Used on 12 VDC models only
311628C
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Technical Data
Working pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 psi (0.07 MPa, 0.7 bar)
Inlet size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 in. npt
Outlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 in. npt
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 lb (9 kg)
Power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ft (5.5 m), 14 AWG (12 VDC models only)
Current draw. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VDC models: 12.5 amps
115 VAC models: 2 amps
Duty cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 min/hour
Suction tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 in. x 34 in. (25.4 mm x 864 mm)
Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . carbon steel with zinc plating, 416 and 302 stainless
®
steel, fluoroelastomer, Buna-N, Aluminum, Valox , Nylon,
Nitrile, PVC, Vellumoid, PTFE, EPDM
®
Valox is a registered trademark of the General Electric Company
Performance Chart
ꢀꢁ
ꢀꢂꢃꢄꢅꢁ ꢂꢃꢂꢄꢅ
ꢀꢂ
ꢀꢂꢃꢆꢇꢁ ꢂꢃꢂꢆꢇ
ꢀꢃ
ꢀꢂꢃꢈꢆꢁ ꢂꢃꢂꢈꢆ
ꢄ
ꢀꢂꢃꢅꢉꢁ ꢂꢃꢂꢅꢉ
ꢅ
ꢀꢂꢃꢉꢇꢁ ꢂꢃꢂꢉꢇ
ꢁ
ꢂ
"
ꢀꢂꢃꢊꢋꢁ ꢂꢃꢂꢊꢋ
ꢀꢂꢃꢇꢉꢁ ꢂꢃꢂꢇꢉ
!
ꢃ
ꢀ
ꢁ
ꢂ
ꢃ
ꢄ
ꢅꢀ
ꢅꢁ
ꢅꢂ
ꢆꢇꢈꢃ
ꢆꢅꢉꢈꢅ
ꢆꢁꢁꢈꢇ
ꢆꢊꢀꢈꢊ
ꢆꢊꢇꢈꢋ
ꢆꢂꢉꢈꢂ
ꢆꢉꢊꢈꢀ
GPM ꢆLPM
&,/7 2!4%
0!24 .5-"%23 ,%'%.$
! ꢌꢇꢊ6$#
0RESSURE
RELIEF OPENS
" ꢌ ꢇꢇꢅ6!#
12
311628C
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
311628C
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 311628
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
311628 10/2006 Revised 9/2009