		 GME8 SEriES   
					Multi-Position, Dual$aver   
					Multi-sPeeD Gas Furnace   
					80% AFUE   
					HeatinG inPut: 70,000–115,000 Btu/H   
					Standard Features   
					• Dual-diameter tubular heat exchanger   
					• Two-stage gas valve that allows installer to   
					turn on two-stage operation with the flip   
					of a dipswitch   
					• Energy-efficient circulator motor (EEM)   
					• 115V Silicon Nitride igniter designed for long igniter life   
					• Furnace control board with self-diagnostics, color-cod-   
					ed low-voltage terminals, and provisions for electronic   
					air cleaner and 24-volt humidifiers   
					• Control board stores the last five diagnostic codes in   
					memory; simple push-button activation outputs the   
					fault history to a flashing red LED   
					• Low constant fan allows homeowner to activate the   
					low heat speed to efficiently circulate air throughout   
					the home.   
					• Self-adjusting feature automatically adjusts furnace to   
					high- or low-stage operation based on outside tem-   
					perature without an outdoor temperature sensor   
					• 
					All models comply with California NOx emissions standards   
					Cabinet Features   
					• Fully insulated, heavy-gauge steel cabinet with durable   
					baked-enamel finish   
					™ 
					• Foil-faced insulation lines the heat exchanger   
					• Designed for multi-position installation: upflow,   
					horizontal left or right   
					• 
					Removable bottom for side- or bottom-return applications   
					• Convenient left or right connection for gas/   
					electric service   
					Contents   
					Nomenclature ................................................................................................... 2   
					Product Specifications ................................................................................. 3   
					Dimensions ......................................................................................................... 4   
					Airflow Data ....................................................................................................... 5   
					Wiring Diagrams .............................................................................................. 6   
					Accessories ......................................................................................................... 8   
					• Top gas connection on most models   
					• Coil and furnace fit flush for most installations   
					* 
					
					Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and   
					10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is   
					not required in California or Québec.   
					SS-GME8   
					
					11/10   
					Supersedes 3/10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ProDuct sPeciFications   
					sPeciFications   
					GME8   
					0703BXC*   
					GME8   
					0905CXC*   
					GME8   
					1155CXC*   
					Performance Data   
					Input¹   
					70,000   
					56,000   
					48,000   
					80   
					90,000   
					72,000   
					64,000   
					80   
					115,000   
					92,000   
					80,000   
					80   
					Output¹   
					LP Output¹   
					AFUE²   
					Tons AC @ 0.5” ESP   
					Temperature Rise Range (°F)   
					Circulator Blower   
					Size (D x W)   
					3 
					5 
					5 
					20 - 50   
					35 - 65   
					35 - 65   
					10 X 8   
					1/2   
					4 
					10 X 10   
					10 X 10   
					HP   
					1 
					4 
					1 
					4 
					Speed   
					Vent Diameter³   
					No. of Burners   
					Disposable Filter (in²)   
					Electrical Data   
					Min. Circuit Ampacity⁴   
					Max. Overcurrent Protecꢀon⁵   
					Ship Weight (lbs)   
					4 
					4 
					4 
					3 
					4 
					5 
					290   
					480   
					480   
					8.2   
					15   
					14.8   
					15   
					14.8   
					15   
					130   
					163   
					167   
					¹ 
					Natural Gas BTU/h: for alꢀtudes above 2,000’, reduce input raꢀng 4% for each 1,000’ above sea level. Low-fire rate is   
					75% of high-fire rate.   
					² 
					³ 
					DOE AFUE based upon Isolated Combusꢀon System (ICS).   
					Vent diameter may vary depending upon vent length. Refer to the latest ediꢀons of the Naꢀonal Fuel Gas Code NFPA   
					54/ANSI Z223.1 (in the USA) and the Canada Naꢀonal Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in   
					Canada).   
					4 
					5 
					Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in ac-   
					cordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.   
					Refers to maximum recommended fuse or circuit breaker size; may use fuses or HACR-type circuit breakers of the same   
					size as noted.   
					Notes   
					• 
					All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.   
					• 
					• 
					Gas Service Connecꢀon ½” FPT   
					Important: It is required to size overcurrent protecꢀon device and wires properly and make electrical connecꢀons in ac-   
					cordance with the Naꢀonal Electrical Code and/or all exisꢀng local codes.   
					SS-GME8   
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					3 
				ProDuct sPeciFications   
					DiMensions   
					Alt. Gas Inlet   
					Alt. Gas Inlet   
					Alt. High Voltage   
					Alt. LowVoltage   
					High Voltage Inlet   
					Low Voltage   
					Model   
					GME80703BXA   
					GME80905CXA   
					GME81155CXA   
					A 
					B 
					17½”   
					21”   
					16”   
					19½”   
					19½”   
					21”   
					MiniMuM clearances to coMBustiBle Materials   
					Vent   
					Sides   
					Rear   
					Front   
					Bottom   
					Top   
					SW   
					B 
					1 
					0 
					3 
					C 
					6 
					1 
					1 
					C = If placed on combusꢀble ꢁoor, the ꢁoor MUST be wood ONLY.   
					Notes:   
					• 
					• 
					• 
					• 
					For servicing or cleaning, a 24” front clearance is recommended.   
					Unit connecꢀons (electrical, ꢁue, and drain) may necessitate greater clearances than the minimum clearances listed above.   
					In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.   
					Refer to the appropriate USA and Canadian codes:   
					◊ 
					◊ 
					In the USA: the Naꢀonal Fuel Gas Code NFPA 54 / ANSI Z223.1   
					In Canada: the Canada Naꢀonal Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2   
					4 
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					SS-GME8   
				ProDuct sPeciFications   
					airFlow Data   
					(CFM & Temperature Rise vs. External Static Pressure)   
					External Static Pressure, (Inches Water Column)   
					Motor   
					Speed   
					Tons   
					AC¹   
					Model   
					0.1   
					0.2   
					0.3   
					0.4   
					0.5   
					0.6   
					CFM   
					556   
					756   
					964   
					0.7   
					CFM   
					509   
					712   
					918   
					0.8   
					CFM   
					460   
					659   
					877   
					CFM   
					875   
					Rise   
					59   
					50   
					43   
					38   
					33   
					53   
					49   
					42   
					38   
					31   
					58   
					52   
					49   
					46   
					37   
					CFM   
					793   
					Rise   
					65   
					54   
					45   
					39   
					34   
					56   
					51   
					44   
					39   
					31   
					60   
					53   
					49   
					47   
					37   
					CFM   
					736   
					Rise   
					70   
					57   
					47   
					41   
					36   
					58   
					53   
					45   
					40   
					32   
					63   
					55   
					50   
					48   
					38   
					CFM   
					674   
					Rise   
					77   
					60   
					49   
					42   
					37   
					61   
					55   
					47   
					41   
					32   
					65   
					57   
					51   
					49   
					40   
					CFM   
					592   
					Rise   
					88   
					64   
					51   
					44   
					38   
					64   
					57   
					48   
					42   
					33   
					68   
					59   
					53   
					50   
					42   
					T1   
					T2   
					T3   
					T4   
					T5   
					T1   
					T2   
					T3   
					T4   
					T5   
					T1   
					T2   
					T3   
					T4   
					T5   
					1½   
					2 
					1,032   
					1,217   
					1,365   
					1,549   
					1,268   
					1,362   
					1,576   
					1,755   
					2,183   
					1,466   
					1,642   
					1,750   
					1,870   
					2,297   
					965   
					914   
					861   
					810   
					GME8   
					0703BXC*   
					2½   
					3 
					1,153   
					1,313   
					1,505   
					1,198   
					1,305   
					1,519   
					1,711   
					2,128   
					1,415   
					1,596   
					1,750   
					1,805   
					2,297   
					1,098   
					1,268   
					1,460   
					1,151   
					1,261   
					1,473   
					1,657   
					2,094   
					1,357   
					1,552   
					1,707   
					1,782   
					2,224   
					1,051   
					1,221   
					1,420   
					1,092   
					1,212   
					1,426   
					1,627   
					2,060   
					1,306   
					1,499   
					1,667   
					1,737   
					2,106   
					1,009   
					1,172   
					1,378   
					1,041   
					1,170   
					1,398   
					1,579   
					2,014   
					1,248   
					1,449   
					1,610   
					1,701   
					2,014   
					1,129 1,086 1,054   
					1,350 1,305 1,268   
					3½   
					2½   
					3 
					988   
					932   
					883   
					1,121 1,074 1,021   
					1,341 1,290 1,252   
					1,548 1,502 1,463   
					1,992 1,944 1,847   
					1,202 1,144 1,088   
					1,388 1,352 1,306   
					1,574 1,531 1,486   
					1,656 1,606 1,571   
					1,896 1,813 1,669   
					GME8   
					0905CXC*   
					3½   
					4 
					5 
					3 
					3½   
					4 
					GME8   
					1155CXC*   
					4 
					5 
					¹ 
					@ 0.5” ESP   
					Notes   
					• 
					CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters,   
					this chart assumes both filters are installed.   
					• 
					• 
					• 
					• 
					• 
					All furnaces ship as high-speed cooling and medium-speed heaꢀng. Installer must adjust blower cooling and heaꢀng speed as needed.   
					For most jobs, about 375 - 400 CFM per ton when cooling is desirable.   
					INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.   
					This chart is for informaꢀon only. For saꢀsfactory operaꢀon, external staꢀc pressure should not exceed value shown on the raꢀng plate.   
					The above chart is for U.S. furnaces installed at 0-2000 feet. At higher alꢀtudes, a properly derated unit will have approximately the same   
					temperature rise at a parꢀcular CFM, while ESP at the CFM will be lower.   
					• 
					• 
					Factory Motor Speed Seꢂng: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling   
					Tempertaure rise data is based on 2nd-stage heat. First-stage heat is 75% of rise indicated above.   
					SS-GME8   
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					5 
				ProDuct sPeciFications   
					wirinG DiaGraM witH Honeywell valve   
					6 
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					SS-GME8   
				ProDuct sPeciFications   
					wirinG DiaGraM witH wHite-roDGers valve   
					INTEGRATED   
					CONTROL MODULE   
					HUMIDIFIER   
					XFMR (6)   
					WARNING:DISCONNECT POWER BEFORE   
					SERVICING.WIRING TO UNIT MUST BE   
					PROPERLY POLARIZED AND GROUNDED.   
					GND   
					GND (8)   
					MVC (9)   
					24 VAC   
					HUMIDIFIER   
					C2   
					GAS   
					HI VALVE   
					MVH (12)   
					MVL (2)   
					M1   
					C 
					ID BLOWER   
					PRESSURE   
					SWITCH   
					AUXILIARY   
					LIMIT CONTROLS   
					C 
					G 
					R 
					W 
					Y 
					G 
					Y 
					NO   
					PS (10)   
					PSO (4)   
					C 
					AUTO   
					1 STG   
					5 MIN   
					2 STG MODE   
					100 SEC   
					150 SEC   
					TO   
					MICRO HLI (7)   
					10 11 12   
					WH   
					BL   
					W 
					7 
					4 
					1 
					8 
					5 
					2 
					9 
					6 
					3 
					HLO (1)   
					AUTO RESET   
					PRIMARY   
					LIMIT   
					FUSE   
					R 
					RO2 (11)   
					RO1 (5)   
					SEE NOTE 6   
					BR   
					CONTROL   
					AUXILIARY   
					LIMITS   
					INTEGRATED   
					CONTROL MODULE   
					MANUAL RESET ROLLOUT   
					LIMIT CONTROL(S)   
					(SINGLE CONTROL ON SOME MODELS)   
					XFMR (3)   
					FS   
					24 VAC   
					40 VA   
					BR   
					BL   
					TRANSFORMER   
					XFMR-N   
					RD   
					XFMR-H   
					115 VAC   
					FLAME SENSOR   
					2 
					1 
					FP   
					HOT SURFACE   
					IGNITER   
					XFMR-H   
					LINE-H   
					EAC-H   
					IGN   
					IND   
					IGN-N   
					PARK   
					ID   
					BLWR   
					BK   
					IND-N   
					BK   
					24V   
					COOL-H   
					CIRCULATOR   
					BLWR   
					115V   
					CIR-N   
					XFMR   
					WH   
					ELECTRONIC   
					AIR CLEANER   
					BK   
					15 PIN PLUG   
					ON SOME MODELS   
					EAC-H   
					LINE-H   
					GR   
					EAC-N   
					BLOWER COMPARTMENT   
					LINE-N   
					JUNCTION BOX   
					BURNER COMPARTMENT   
					DOOR   
					SWITCH   
					24 VAC   
					HUMIDIFIER   
					DOOR SWITCH   
					SWITCH LOCATED IN BLOWER   
					COMPARTMENT ON SOME MODELS   
					NO   
					C 
					WARNING:   
					RD   
					RD   
					DISCONNECT POWER   
					BEFORE SERVICING.   
					WIRING TO UNIT   
					MUST BE   
					PROPERLY   
					POLARIZED   
					DISCONNECT   
					PRESSURE   
					SWITCH   
					YL   
					YL   
					PRIMARY LIMIT   
					YL   
					RD   
					YL   
					WH   
					BK   
					AND GROUNDED.   
					L 
					GND   
					N 
					BR   
					TO 115VAC/ 1   
					OVERCURRENT PROTECTION DEVICE   
					Ø /60 HZ POWER SUPPLY WITH   
					BL   
					WH   
					BK   
					PM   
					1 
					C 
					2 
					HI   
					3 
					JUNCTION   
					BOX   
					HOT   
					SURFACE   
					IGNITER   
					2 STAGE   
					GAS VALVE   
					LINE-N   
					GND   
					LINE H   
					PU   
					INDUCED DRAFT   
					BLOWER   
					TO 115 VAC/ 1/60HZ   
					POWER SUPPLY WITH   
					OVERCURRENT PROTECTION   
					DEVICE   
					PU   
					PU   
					FLAME   
					SENSOR   
					ROLLOUT LIMITS   
					(SINGLE CONTROL ON SOME MODELS)   
					0 
					STEADY ON = NORMAL OPERATION   
					LOW VOLTAGE (24V)   
					LOW VOLTAGE FIELD   
					HI VOLTAGE (115V)   
					HI VOLTAGE FIELD   
					JUNCTION   
					EQUIPMENT GND   
					FIELD GND   
					OFF   
					= CONTROL FAILURE   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					C 
					1 FLASH   
					= 
					SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)   
					2 FLASHES = PRESSURE SWITCH STUCK CLOSED   
					3 FLASHES = PRESSURE SWITCH STUCK OPEN   
					4 FLASHES = OPEN HIGH LIMIT   
					FIELD SPLICE   
					SWITCH (TEMP.)   
					IGNITER   
					5 FLASHES = FLAME SENSE WITHOUT GAS VALVE   
					TERMINAL   
					6 FLASHES =   
					OPEN ROLLOUT OR OPEN FUSE   
					SWITCH (PRESS.)   
					INTERNAL TO   
					INTEGRATED CONTROL   
					7 FLASHES = LOW FLAME SIGNAL   
					OVERCURRENT   
					PROT. DEVICE   
					8 FLASHES = CHECK IGNITER OR IMPROPER GROUND   
					RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND   
					PLUG CONNECTION   
					NOTES:   
					1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.   
					2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.   
					PK PINK   
					COLOR CODES:   
					YL YELLOW   
					OR ORANGE   
					PU PURPLE   
					GR GREEN   
					BR BROWN   
					WH WHITE   
					BL BLUE   
					GY GRAY   
					RD RED   
					3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH   
					WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER CONDUCTORS ONLY.   
					4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO   
					PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR   
					FLOW CHART)   
					5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.   
					6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS   
					WHILE IN STANDBY(NO THERMOSTAT INPUTS).   
					BK BLACK   
					0140F00643 REV. A   
					SS-GME8   
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					7 
				ProDuct sPeciFications   
					Dual$aver conFiGuration oPeration   
					& 
					Dual$aver™   
					This furnace is capable of the following heating modes:   
					• 
					• 
					Single Stage (Factory Setting)   
					Modified Two-Stage   
					» 
					» 
					Fixed 5-Min Low Stage   
					Auto Time (1-12 Min) Low Stage   
					Start   
					Call for Heat   
					Safety Circuit Check   
					Start Furnace   
					in Low Stage   
					Low-Heat Blower   
					Delay Time (5 Min)   
					or Delay Time (1-12 Min)   
					Gas Valve Switch   
					to 2nd Stage   
					Blower Switch to   
					Hi Heat Operaꢀon   
					T-Stat Saꢀsfied   
					accessories   
					GME8   
					0703BX   
					GME8   
					0905CX   
					GME8   
					155CX   
					Model   
					Description   
					LPM-05   
					LPM-06   
					LP Conversion Kit (Springs & Orifice)¹   
					LP Conversion Kit (Springs & Orifice)²   
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					√ 
					FSRKG-14/17/21/24 Noise Reducꢀon Kits   
					MVK-01³   
					HA02   
					Masonry Vent Kit   
					High-Alꢀtude Natural Gas Kit   
					Fossil Fuel Kit   
					AFE18-60A   
					¹ 
					² 
					³ 
					White-Rodgers valves only   
					Honeywell or White-Rodgers valves   
					Upꢁow applicaꢀons only   
					Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without   
					notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.   
					8 
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					SS-GME8   
				 | 
Eiki Network Card LC XNB3W User Manual
Electro Voice Car Speaker sb121a 110v User Manual
Estate Range W10173755D User Manual
Fellowes Laminator L80 95 User Manual
Fellowes Paper Shredder SB 125Ci User Manual
First Alert Home Security System 3035DEF User Manual
Garland Convection Oven ECO E 10 E User Manual
GE Heat Pump AZ58H12E User Manual
Generac Portable Generator 005882 1 User Manual
Goodman Mfg Heat Pump GSZ11 User Manual