Gianni Industries Door VDH 100 User Manual

VDH-100  
Full Color Villa Video Door Phone  
Four wires villa system indoor monitor  
Indication lighting  
6" LCD full color screen  
2-way communication  
Chroma/Contrast  
Volume  
Crystal clear speaker system  
Clear and bright pictures  
Quick and easy connection  
Brightness  
TFT screen  
Speaker  
Extension call transferring  
Door releasing  
Hands-free talking  
Microphone  
Four wires video system with integral  
keypad access  
CCD camera  
Water cover  
Illumination light  
Metal external housing  
Auto keypad illumination in darkness  
40 user PIN  
Speaker unit  
Light sensor  
Programmable lock timer(01~99s)  
Latching relay facility  
Narrow style  
Call button  
LED indication  
1
4
7
2
5
8
0
3
6
9
Keypad access  
Maximal component: 2 color video monitors  
+ one outdoor station  
Specifications  
Power input :12~18 VDC  
Indoor monitor  
Indoor monitor  
Stand by :12 mA  
Camera : 1/3 CCD lens  
Mode : Dual transmission  
4C  
Temperature : -20~+55°C  
Working current : 600 mA  
Illumination : 0.05 LUX  
Talking time : 2 minutes  
Power Supply  
12 VDC  
Power Supply  
12 VDC  
System connection  
4C (Longest cable distance< 30 M.)  
Normal 4C cable , cable dia. > 0.5 mm, longest cable distance  
< 30 M.  
Input power: 12 VDC, 800mA  
4C wires must be connected as below:  
Outdoor station  
Lock device  
(Fail-safe)  
Com.  
N. C.  
Power Supply  
12 VDC  
Audio(white)  
Power+(red)  
GND(black)  
Example:  
Video(purple)  
1
4
7
2
5
8
0
3
6
9
Use the normal cable:  
Every unit need a power supply except outdoor station.  
Do not use the STP cable:  
GIANNI INDUSTRIES, INC.  
No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone,  
Tu-Cheng City, Taipei, Taiwan 23678  
Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876  
Website: gianni.tw  
The products are manufactured under an ISO  
9001  
&
QC 080000 Certified Quality  
Management Program environment back its  
product quality, performance and commitment  
to customer satisfaction.  
Copyright 2008 Gianni industries, inc. All rights reserved.  
DM-CA-VDH-100 Ver. A Published on 2008.09.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VDH-100  
Full Color Villa Video Door Phone  
Dimension  
System wire diagram  
The next Indoor monitor  
Power Supply  
12 VDC  
Red Black  
Indoor monitor  
Video(purple)  
Audio(white)  
GND(black)  
Power+(red)  
Power+(red)  
GND(black)  
Audio(white)  
Video(purple)  
Unit: mm  
Lock device  
(Fail-safe)  
Com.  
N. C.  
1
4
7
2
5
8
0
3
6
9
Power Supply  
12 VDC  
Outdoor station  
Indoor monitor  
Power+(red)  
GND(black)  
Audio(white)  
Video(purple)  
Audio  
Socket  
Video  
EGR  
0V  
Push button  
TM CLK  
N. O.  
Power Supply  
12 VDC  
Com.  
N. C.  
150 cm  
(Fail-safe)  
N. O.  
Com.  
Power Supply  
12 VDC  
N. C.  
Push  
(Fail-secure)  
GIANNI INDUSTRIES, INC.  
No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone,  
Tu-Cheng City, Taipei, Taiwan 23678  
Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876  
Website: gianni.tw  
The products are manufactured under an ISO  
9001 QC 080000 Certified Quality  
Management Program environment back its  
product quality, performance and commitment  
to customer satisfaction.  
&
Copyright 2008 Gianni industries, inc. All rights reserved.  
DM-CA-VDH-100 Ver. A Published on 2008.09.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VDH-100  
Full Color Villa Video Door Phone  
Operation Instruction  
The Master Code is set to 1234 as factory default.  
Setting the relocking timer  
Enter Programming Mode  
Factory default set is 0.5 second.  
Compose twice the master code (Factory  
master is 1234)  
Enter the Programming mode Enter 99→  
Enter the desired lock / relay operation time in a  
two digit format (01~99 seconds) Press #」  
to exit from the programming mode, or  
programming other operating. The lockout facility  
will operate.  
an audible and the LED will flash red you are now in the  
"programming mode".  
Exiting from the program mode  
Press#to exit from the programming mode.  
The system will out of the programming  
Master Code reset to Factory 1234」  
Remove power from the unit and hold down the「 * 」key. →  
Apply power whilst holding button down, the unit will then give  
long continuous tone. When the tone has stopped, Press  
00#The Master code reset to Factory 1234.  
Change the Master code  
Enter the Programming mode, Enter the slot position code  
00Enter the new master code 「????」the long beep  
sound heard The new Master code is set.  
Care and maintenance  
Add PIN codes  
1. Do not put the outdoor sation near the magnetic area such  
as televison, video recorder etc.  
2. Do not drop, knock or shake the unit.  
Enter the Programming mode, Enter the slot position code  
01~40」 →???? Input 4 digit PIN codes(beep) enrolled.  
Press #to exit from the programming mode, or program  
other operating.  
3. Do not put the  
outdoor sation in hot areas, high  
temperatures can shorted the life of electronic device.  
4. Do not attempt to open the unit, non expert handing may  
damage the unit.  
5. Keep the indoor monitor dry, humidity and all types of  
liquids or moisture contains mineral that will corrode  
electronic circuits.  
Note : The codes0000,1234or master code are not be  
used for PIN code.  
6.Do not use the wet dishcloth or the volatile cleansers to  
clean it.  
7. The installation position of outdoor station and indoor  
monitor should be about 150 cm height.  
8. Power must be shut off when installing.  
Delete a PIN Code  
Enter the Programming modePress the slot position code of  
your choice to delete (example "06") Press「 * 06」 →  
0000(beep)deletePress#to exit from the  
programming mode, or programming other operating.  
Delete all PIN Codes  
Enter the Programming modePress 「 *88」(The red LED  
will remain on.) Press0000(The red LED turn off,  
beep)→Indicate that the delete all PIN codes.  
Warranty  
The product is warranted against defects in material and  
1
workmanship while used in normal service for a period of  
year from the date of sale to the original customer. The GEM  
policy is one of continual development and improvement;  
therefore GEM reserves the right to change specifications  
without notice.  
GIANNI INDUSTRIES, INC.  
No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone,  
Tu-Cheng City, Taipei, Taiwan 23678  
Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876  
Website: gianni.tw  
The products are manufactured under an ISO  
9001  
&
QC 080000 Certified Quality  
Management Program environment back its  
product quality, performance and commitment  
to customer satisfaction.  
Copyright 2008 Gianni industries, inc. All rights reserved.  
DM-CA-VDH-100 Ver. A Published on 2008.09.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Trimmer SRM 225I User Manual
EFJohnson Satellite Radio 002 9800 401 User Manual
Estate Range 336 User Manual
Flymo Trimmer Trmmer User Manual
Gardena Garage Door Opener 7874 User Manual
GBC Laminator 930 073 User Manual
GE Drill GE752 User Manual
GE Microwave Oven HVM1540 User Manual
GE Monogram Saw ZDP48L4GWSS User Manual
GE Washer Dryer EWA2000 User Manual