Generac Power Systems Switch 5464 User Manual

STANDBY GENERATOR ACCESSORIES  
21 Light Remote Annunciator  
Liquid-Cooled Generator Sets  
Model 5465  
Model 5466  
Model 5464  
DESCRIPTION  
The Remote Annunciator Panel provides remote monitoring and  
annunciation of up to 18 generator parameters using LED’s located on  
the annunciator keypad. It also provides two system level warnings which  
are System Ready and Communications OK.  
The specific faults can be selected using either the DIP switches located  
on the annunciator circuit board or through a computer via the RS232  
connection on the circuit board.All relays are energized on power up and  
open during a fault condition.  
The Relay panel has up to 8 selectable functions on form A relays,  
and multiple relay panels can be connected for all 18 generator  
parameters.  
Communication is via a RS485 serial data link and power is supplied by  
the generator battery (+12 VDC or +24 VDC)  
Note:These units are only compatible with the H-series generator  
controller (70-150 kW)  
ENVIRONMENTAL SPECIFICATIONS  
Operating Temperature.......................................................................................................................................................................... -25 º C to 60 º C  
Humidity............................................................................................................................................................................... 0 to 95% Non-Condensing  
Power Supply..........................................................................................................................................................................................+12 or +24 VDC  
Power Usage ............................................................................................................................................................................................ 6 Watts typical  
Power Supply.......................................................................................................................................................................................Generator Battery  
Communication Line..........................................................................................................................RS485 fully isolated twisted pair cable with shield  
Maximum Cable Length.................................................................................................................................................................................... 4000 feet  
Relay Output.............................................................................One NO contact (Engergized when annunciator is powered and no faults are present)  
Relay Contact Rating..............................................................................................................................................................................30 VDC, 1 amp  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eizo Computer Monitor S2133 User Manual
ETA Systems Surge Protector ETA S20 User Manual
ETI Sound Systems INC DJ Equipment LHEC20 User Manual
Excalibur electronic Fan FN10 BB User Manual
Fluke Stereo Amplifier 5205A User Manual
Frigidaire Dishwasher FFBD2409L User Manual
Frigidaire Microwave Oven FGMO205K User Manual
GBC Binding Machine P70IX User Manual
GE Convection Oven SCB 1000 User Manual
Good Way Tech Network Card AP1305 User Manual