Genelec Speaker 7060B User Manual

Operating Manual  
LSE Series  
Genelec 7060B, 7070A and 7071A  
Active Subwoofers  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 2. XLR to RCA connector for  
unbalanced operation.  
Figure 3. Recommended distances to  
the front wall  
Figure 1. 7070A's connector panel, connectors and controls.  
matrix surround decoder (Dolby Surround,  
Dolby Pro Logic) should not be connected to  
the "LFE IN" input. See section "Subwoofer  
in analogue matrix sound systems".  
system. The connection is made in the same  
To begin with, place the subwoofer slightly  
offset from the center of the front wall. The  
recommended distance to the wall is less  
than 60 cm / 24" measured from the sub-  
woofer's driver (See Fig. 3). This position  
gives increased acoustic loading (and SPL)  
due to the proximity of the front wall and floor.  
Cancellations from the front wall and floor are  
also avoided. Front wall cancellation for the  
85 Hz high pass filtered main speakers can  
be eliminated by placing them at least 110  
cm / 43" away from the front wall. In a mul-  
tichannel system the main monitors should  
ideally be positioned symmetrically and at an  
equal distance from the listening position.  
If the frequency balance is not right, try  
moving the subwoofer slightly to the left or  
right so that different room modes are excited  
at different levels. Positioning the subwoofer  
close to a corner will boost the bass level  
at lower frequencies and may cause asym-  
metrical spatial imaging. If you are using two  
subwoofers, try placing them asymmetrically  
relative to the side walls. Sometimes moving  
the subwoofers apart into the front corners  
helps with problematic rear wall reflections  
and the loss of mutual coupling is compen-  
sated by the bass boost caused by corner  
positioning.  
way as with the Front channels. Also these  
channels are high pass filtered at 85 Hz.  
Once all connections have been made, the  
subwoofer and main monitors are ready to be  
powered up.  
SUM OUT: Use this output connector when  
you want to link another subwoofer to your  
system. "SUM OUT" carries an unfiltered sum  
of signals combined from all input channels.  
See section "Using multiple subwoofers".  
Positioning in the room  
The placement of the subwoofer in the room  
affects the overall frequency response and  
sound level of the system dramatically, as at  
low frequencies the effects of the room are  
strong. Even a slight change in the subwoof-  
er's location can make a marked difference  
in the frequency balance and often patient  
and methodical experimentation and testing  
is needed to find the optimum placement.  
The placement will affect the phase dif-  
ference between the main monitors and the  
subwoofer, and also the bass roll-off rate.  
These effects can be compensated by the  
use of the controls in the amplifier unit; but  
we recommend that at first you leave the  
switches untouched and concentrate on find-  
ing the position where the subwoofer gives  
the smoothest response, and only then use  
the controls to fine-tune the balance and  
phase alignment between the subwoofer and  
the main monitors.  
Middle row  
FRONT L, C, R CHANNELS IN/OUT: Use  
these connectors for the Front Left, Center  
and Right channels of a surround sound  
system or the Left and Right channels of a  
Stereo system. Connect line level signal  
cables from your signal source to their respec-  
tive "LEFT IN", "CENTER IN" and "RIGHT IN"  
connectors. Then connect the subwoofer to  
your main monitors with XLR cables from the  
"LEFT OUT", "CENTER OUT" and "RIGHT  
OUT" connectors. All "L, C and R OUT" chan-  
nels are high pass filtered with the filtering  
frquency fixed at 85 Hz (12 dB/octave).  
Bottom row  
REAR L, C, R CHANNELS IN/OUT: Use  
these connectors for the Rear Left, Center  
and Right channels of a surround sound  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bass Roll-Off  
setting  
Subwoofer placement  
Near to a wall  
-2 dB  
-6 dB  
-2 dB  
In a corner  
Flush mounted  
Phase Difference: 0°  
Phase Difference: 90°  
Table 1. Suggested Bass Roll-Off settings  
85 Hz  
85 Hz  
Phase Difference: 270°  
Phase Difference: 180°  
85 Hz  
85 Hz  
Figure 5. Flush mounting the subwoofer.  
Note the clearance needed on the reflex  
port side.  
Figure 4. The effect of phase difference between the subwoofer and the main monitors  
Although the 7060B, 7070A and 7071A  
subwoofers are magnetically shielded, they  
may cause some picture distortion if placed  
near very sensitive video monitors or com-  
puter displays. Move the subwoofer further  
away or try turning the driver side of the  
subwoofer away from the screen.  
fier cooling. This can be done by making the  
panel. Table 1 provides some suggestions  
for the "Bass Roll-Off" switch settings. When  
both roll-off switches are set to "OFF", a flat  
anechoic response is obtained.  
recess 7,5 centimeters (3") wider than the  
subwoofer. Place the subwoofer into the right  
end of the recess with the driver side facing  
the room. This leaves sufficient 7,5 centime-  
ters (3") of free space on the reflex port side.  
The height and depth of the recess should  
not be any bigger than those needed to fit  
the subwoofer flush with the wall surface.  
Setting the phase control  
Incorrect phase alignment between main  
monitors and subwoofer causes a drop in the  
frequency response of the whole system at  
the crossover frequency. The graphs above  
(Fig. 4) show the effect of phase difference  
to the frequency response.  
Minimum clearances to walls  
or other objects  
Setting the input sensitivity  
The power amplifiers are attached to the  
lower part of the aluminium grille, which func-  
tions as a heatsink. Do not cover the grille  
or place the subwoofer so that there is less  
than 10 centimeters (4") of free space in front  
of the grille.  
The subwoofer requires input sensitivity  
alignment to the source to obtain a correctly  
balanced system. The input sensitivity con-  
trol is located on the connector panel of the  
subwoofer. An input voltage of -6 dBu with a  
-6 dBu input sensitivity setting will produce  
100 dB SPL @ 1m in free field. To obtain a  
110 dB SPL output an input voltage of +10  
dBu is required when the input sensitivity is  
set to 0 dBu.  
The phase difference between the main  
monitors and subwoofer at the listening posi-  
tion is dependent upon the position of the  
subwoofer, so the phase adjustment should  
be done only after the preferred position is  
found. Acoustic measuring equipment is  
required for accurate system alignment. If  
this equipment is not available, the following  
coarse phase matching can be applied.  
Make sure that the space underneath the  
subwoofer is clear from obstructions. Thick  
carpets may block the ventilation clearance  
needed for cooling the electronics' box.  
The reflex port side (opposite of the con-  
nector panel side) should always have a  
clearance of at least 7,5 centimeters (3") to  
any objects to ensure proper functioning of  
the reflex port.  
Setting the Bass Roll-Off  
switches  
Coarse phase adjustment  
method  
The acoustic response of the subwoofer may  
have to be matched to the characteristics of  
the room and the positioning in which it will  
be used. To adjust the subwoofer to match  
these characteristics use the ''Bass Roll-Off'  
control switches located on the connector  
Genelec 7060B, 7070A and 7071A  
subwoofers are equipped with a built-in 85  
Hz frequency test tone generator for easy  
phase alignment. The test tone generator  
is connected to the subwoofer's "FRONT  
CENTER OUT" channel only. In a stereo  
Flush mounting the subwoofer  
If the subwoofer is flush mounted into a wall  
or a cabinet, it is important to ensure unre-  
stricted airflow from the reflex port and ampli-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
can be used to bring it into view. The kit con-  
sists of a LED in a compact case and a RJ11  
cable to connect the case and the "REMOTE"  
RJ11 connector on the connector panel.  
Maximum  
room  
Maximum  
listening  
distance,  
m (ft)  
Front  
loudspeakers  
Stereo & LCR  
Side and rear  
loudspeakers  
Subwoofers  
for 2-channel  
Stereo  
Subwoofers  
for 5-channel  
Surround  
volume,  
m3 (ft3)  
75 (2,600) 2.0m (6’7”)  
75 (2,600) 2.0m (6’7”)  
85 (3,000) 2.2m (7’3”)  
95 (3,400) 2.3m (7’7”)  
110 (3,900) 2.4m (7’10”)  
125 (4,400) 3.5m (11’6”)  
8030A  
8130A  
8040A  
8050A  
1032A  
1037C  
8030A  
8130A  
8040A  
8050A  
1032A  
1037C  
1038B  
1038B  
1038B  
1038B  
1038B  
7050B  
7050B  
7060B  
7070A  
7070A  
7071A  
7071A  
7071A  
2x7071A  
7060A  
7060A (1)  
7070A  
Subwoofer bypass control  
7070A  
A bypass control feature is included in the  
subwoofer circuits so that the effect of the  
subwoofer on the whole monitor system can  
be determined. With the bypass switch on,  
the high pass filters for the main monitors are  
overridden and the system behaves as if the  
subwoofer was not connected. The bypass  
function has no effect on the LFE input. Two  
different bypass remote controllers are avail-  
able as optional equipment: 1092-400 switch  
that can be connected to a 1/4" jack connec-  
tor on the connector panel and 7000-416 that  
connects to the "REMOTE" RJ11 connector.  
The 7000-416 option also includes remote  
control of the "LFE +10 dB" function and a  
link for the 7000-415 remote LED option.  
7071A  
2x7071A  
2x7071A  
2x7071A (2)  
2x7071A (2)  
170 (6,000) 4.0m (13’1”) 1038B & 1038BC  
200 (7,000) 4.5m (14’9”) 1034B & 1034BC  
240 (8,500) 4.7m (15’5”)  
400 (14,000) 5.5m (18’1”)  
400 (14,000) 5.5m (18’1”)  
(1) When using a digital input signal, the 8130A cannot be used with the subwoofer’s analogue crossover  
filters. The subwoofer can be used for reproducing the LFE channel only.  
1039A  
1035B  
1036A  
2x7071A (2)  
3x7071A (2)  
(3)  
(3)  
(2) Additional subwoofers of the same type may be required in a larger room with bass heavy program material.  
(3) Subwoofers are not necessarily required for a 1036A installation as these monitors are already full range.  
For surround systems, subwoofers can be used to reproduce the LFE channel.  
Table 2. Recommended subwoofer/main monitor combinations.  
Subwoofer in analogue matrix  
surround sound systems.  
system it is necessary to temporarily connect  
either of the channels to this output.  
tors using a frequency analyser and a pink  
noise generator. Connect a high grade  
measuring microphone to the analyser and  
feed pink noise into the "CENTER IN" input  
of the subwoofer. The subwoofer's bass  
management system will direct the frequen-  
cies above 85 Hz to the center main monitor  
while the subwoofer reproduces the frequen-  
cies below 85 Hz.  
Power up the system and set the DIP  
switches 3 (SUM IN MODE) and 4 (LFE +10  
dB) on the first switch group to "ON" Now you  
should hear an 85 Hz test signal from the  
subwoofer and the main monitor connected  
to the center channel output.  
When using Genelec 7060B, 7070A or  
7171A subwoofers in a consumer analogue  
matrix surround sound system, such as  
Dolby Surround, Dolby Pro-Logic or Pro-  
Logic II or a professional matrix decoder  
such as a Dolby SDU-4, route the front chan-  
nels through the subwoofer so that the output  
of the subwoofer is matched to the rest of the  
system and select "Large" setting for the  
front speakers on the decoder. If there is a  
subwoofer channel output on the decoder it  
should NOT be connected to the subwoofer's  
"LFE IN" input since the processing within an  
analogue decoder will conflict with the filter-  
ing in the subwoofer. Connecting the rear  
channels to the subwoofer is optional since  
the rear channels from most matrix decoders  
are band limited down to 100 Hz.  
Toggle the -180° phase switch  
(DIP 4 on the second switch  
group) on and off, and set it to  
the position which gives the  
lowest sound level at the listen-  
ing position.  
Position the microphone at the listening  
position and adjust the input sensitivity of  
the subwoofer until frequencies below and  
above 85 Hz are reproduced at equal level.  
Then adjust the phase control switches for  
the maximum dip of at least -6 dB at the  
crossover frequency (85 Hz).  
Next toggle the -90° phase  
switch (DIP 3) on and off, and  
again set it to the position which  
gives the lowest sound level.  
Change the -180° switch to the opposite  
setting. The phase should now be set cor-  
rectly and the frequency analyser should  
show a smooth response around 85 Hz.  
Overload indicators  
Monitoring the LFE channel  
in digital discrete surround  
sound systems  
Some digital surround sound systems use  
a discrete Low Frequency Effects channel  
which should be connected to the "LFE IN"  
input on the connector panel. This enables  
the subwoofer to correctly reproduce all the  
bass information in the mix.  
Finally, set the -180° phase  
switch (DIP 4) to the opposite  
setting and deactivate the test  
signal.  
The mode indicator LED on the connector  
panel will turn from green to yellow to indi-  
cate clipping and then to red to indicate that  
the protection circuit has activated. If this  
occurs frequently, reduce the input level to  
the subwoofer until the LED remains green.  
If the LED on the connector panel is not  
easily visible, the optional Remote LED Kit  
Phase correction method with  
test equipment  
The following procedure matches the phase  
between the subwoofer and the main moni-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The LFE channel on the 7060B, 7070A and  
7071A can be set to two frequency ranges:  
19 to 85 Hz or 19 to 120 Hz by using the  
"LFE BANDWIDTH" switch. If the LFE signal  
includes higher frequencies than 120 Hz,  
they can be monitored by using the "Redi-  
rect" function: Set "LFE BANDWIDTH" switch  
to "85" and the "REDIRECT" switch to "ON".  
Now the subwoofer reproduces LFE frequen-  
cies up to 85 Hz and reroutes all higher LFE  
content to the front center channel. This is  
the most flexible setting for LFE signal man-  
agement, as it ensures that all LFE content  
can be monitored in all situations and encod-  
ing formats. Note that the "Redirect" function  
is not enabled when the "LFE BANDWIDTH"  
switch is set to 120 Hz.  
+10 dB gain in relation to the main channels.  
The object is to increase the recording head-  
room of the LFE channel. Consumer and the-  
atrical decoders automatically add +10 dB of  
LFE gain to restore the level balance.  
woofer in the chain, especially if they are not  
placed close together. To check the phase  
alignment for the "master" subwoofer switch  
off the "slave" subwoofer and follow the  
instructions given in the previous sections.  
To adjust the phase alignment of the  
"slave" subwoofer, you need to switch off  
the "master" subwoofer, connect a signal  
cable from the "slave" subwoofer's "FRONT  
CENTER OUT" connector to the center chan-  
nel monitor and switch the "SUM IN MODE"  
switch to "OFF". This effectively changes  
the "slave" to "master" mode and the phase  
adjustment can be carried out. Return the  
connections and "SUM IN MODE" setting on  
the "slave" subwoofer back to the "SUM IN"  
mode after completing the adjustment.  
The "LFE +10 dB" function on the 7060B,  
7070A and 7071A subwoofers is designed to  
add the +10 dB gain to the LFE channel in the  
production stage, if it is not already done in  
the output matrix of the mixing console. The  
function is activated by switching the "LFE  
+10 dB" dip switch on the subwoofer's first  
switch group to "ON" or by using the remote  
control. A yellow LED indicates that the func-  
tion has been activated.  
The "LFE +10 dB" function should not be  
used in following cases:  
Safety considerations  
Typical applications of different  
LFE bandwidth settings  
If the +10 dB LFE gain is already  
implemented by another device.  
When producing an audio format that  
does not require the use of +10 dB  
gain on the LFE channel, such as  
DVD-Audio (MLP), SACD (DSD) etc.  
When monitoring a decoded Dolby  
Digital or DTS soundtrack. The decoder  
will automatically provide +10 dB  
LFE gain.  
The LSE series subwoofers have been  
designed in accordance with international  
safety standards. However, to ensure safe  
operation and maintain the unit in safe oper-  
ating condition, the following warnings and  
cautions must be observed:  
As stated above, using the 85 Hz LFE band-  
width setting with "Redirect" function is the  
most universal configuration for LFE monitor-  
ing. However, there are situations when the  
band-limited LFE settings serve a definite  
purpose.  
Limiting the LFE bandwidth to 85 Hz without  
using the "Redirect" function can be used to  
simulate the effect of some consumer decod-  
ers that do not replay information above 80  
Hz on the LFE channel when the bass man-  
agement is used. Checking the multichannel  
mix with this setting on lets you know how it  
translates in systems with this limitation.  
The 120 Hz LFE bandwidth setting com-  
plies with the replay systems of movie theat-  
ers and cinemas. 35 mm movie soundtracks  
use the LFE channel to reproduce a band-  
width of 20 - 120 Hz through dedicated  
subwoofers. In this case the LFE and main  
channel bandwidths overlap between 85 and  
120 Hz, which may create unwanted acous-  
tical summing if the same signal is present  
in both channels. To avoid this, the LFE con-  
tent should be kept completely different (de-  
correlated) from the low frequency content  
of the main channels when mixing music  
and sound effects for film release.  
Do not expose the subwoofer to water  
or moisture. Do not place any objects  
filled with liquid, such as vases on  
the subwoofer or near it.  
Using multiple subwoofers  
Genelec 7060B, 7070A and 7071A subwoofers  
are equipped with a "SUM OUT" connector to  
provide an easy way of coupling two or more  
subwoofers together in high SPL applications.  
Table 2 shows the recommended configura-  
tions with different Genelec monitors. Connect  
an XLR cable from the "SUM OUT" connector  
of the "master" subwoofer to which the main  
monitor channels are connected, to the "LFE  
IN / SUM IN" connector of the other, "slave"  
subwoofer and turn the "SUM IN MODE" dip  
switch on the "slave" subwoofer to "ON".  
When two subwoofers connected in this  
way are positioned close to one another,  
bass level increases by 6 dB. Three sub-  
woofers give an SPL increase of 9,5 dB and  
four subwoofers 12 dB compared to a single  
subwoofer. Adjust the sensitivity control of all  
subwoofers in the group to match the SPL  
level of the main monitor system.  
Do not place naked flame sources like  
lighted candles on or near the  
subwoofer  
Servicing and adjustment must only  
be performed by qualified service  
personnel.  
Opening the connector panel is  
strictly prohibited except by  
qualified service personnel.  
Always use a mains power connection  
and cable with protective earth. Failing  
to do this may lead to personal injury.  
Note that the amplifier is not completely  
disconnected from the AC mains  
service unless the mains power cord  
is removed from the amplifier or the  
mains outlet.  
Warning!  
Using the LFE +10 dB function  
In Dolby Digital and DTS encoding formats  
the LFE channel has to be monitored with  
This equipment is capable of delivering sound  
pressure levels in excess of 85 dB, which  
may cause permanent hearing damage.  
Phase and Bass Roll-Off adjustments  
should be done individually for each sub-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 7. 7000-415 Remote  
Power/OVL LED  
Figure 8. 7000-416 Remote control switch  
for "Bypass" and "+10 dB LFE" functions  
Figure 6. 1092-400 "Bypass" switch  
Maintenance  
No user serviceable parts are inside the ampli-  
fier unit. Any maintenance work must only be  
performed by qualified service personnel.  
Guarantee  
This product is supplied with a one year guar-  
antee against manufacturing faults or defects  
that might affect the performance of the unit.  
Refer to supplier for full sales and guarantee  
terms.  
Accessories  
1092-400 1/4” jack "Bypass" switch  
7000-415 RJ11 remote Power/Overload  
indicator LED  
Figure 9. The free field frequency response  
of the 7060B subwoofer at different Bass  
Roll-Off settings  
Figure 10. The free field frequency  
response of 7070A and 7071A subwoofers  
at different Bass Roll-Off settings.  
7000-416 RJ11 remote control for  
"Bypass" and "+10 dB LFE"  
functions  
EC Declaration of Conformity  
This is to certify that Genelec 7060B, 7070A  
and 7071A active subwoofers conform to  
the following standards:  
Safety:  
EN 60065 / IEC 60065:1998 7th Edition  
EMC:  
EN 55013: (2001)  
EN 55020: (1994), A11: (1996), A12: (1999),  
A13: (1999), A14: (1999)  
EN 61000-3-2 (2000), EN 61000-3-3 (1995)  
The products herewith comply with the  
requirements of The Low Voltage Directive  
73/23/EEC, EMC Directive 89/336/EEC and  
93/68/EEC  
Signed:  
Ilpo Martikainen  
Position: Chairman of the Board  
Date:  
28-February-2006  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7060B, 7070A and 7071A Operating Manual  
SYSTEM SPECIFICATIONS  
AMPLIFIER SECTION  
7060B  
7070A  
7071A  
7060B  
7070A  
7071A  
Free field frequency response  
(+/- 3 dB)  
19 Hz…85 Hz  
LFE 85/120 Hz  
19 Hz…85 Hz  
LFE 85/120 Hz  
19 Hz…85 Hz  
LFE 85/120 Hz  
Short term amplifier output  
power (Long term output power  
is limited by driver unit  
Maximum short term sine wave  
SPL output averaged from  
30 to 85 Hz, measured in  
half space at 1 meter  
protection circuitry)  
120 W  
250 W  
500 W  
Amplifier system distortion  
at nominal output  
THD  
≥ 108 dB SPL  
≥ 113 dB SPL  
≤ 15 dB  
≥ 112 dB SPL  
≥ 117 dB SPL  
≥ 118 dB SPL  
≥ 123 dB SPL  
≤ 0.05%  
Maximum peak SPL output with  
random pink noise, measured  
in half space at 1 meter  
Mains voltage  
230 V, 115/230V or 100/200V  
according to region  
Self generated noise level in  
free field @ 1 m on axis  
(A-weighted)  
Power consumption (average)  
Idle  
Full output  
15 VA  
150 VA  
15 VA  
250 VA  
30 VA  
500 VA  
Harmonic distortion  
@ 90 dB SPL  
30 … 85 Hz  
≤ 3 %  
@ 95 dB SPL  
30 … 85 Hz  
≤ 3 %  
@ 100 dB SPL  
30 … 85 Hz  
≤ 3 %  
at @ 1 m on axis in half space  
2nd  
3rd  
≤ 2 %  
≤ 3 %  
≤ 3 %  
Driver, magnetically shielded  
Weight  
250 mm (10”)  
26 kg (57 lbs)  
305 mm (12”)  
2 x 305 mm (12”)  
81 kg (178 lbs)  
INPUT SECTION  
50 kg (110 lbs)  
Dimensions  
Height  
7060B  
7070A  
7071A  
527 mm (20 3/4”)  
462 mm (18 3/16”)  
363 mm (14 5/16”)  
625 mm (24 5/8”)  
555 mm (21 7/8”)  
490 mm (19 5/16”)  
755 mm (29 3/4”)  
803 mm (31 5/8”)  
490 mm (19 5/16”)  
Width  
Input connector XLR female  
Depth  
pin 1  
pin 2  
pin 3  
gnd  
+
Input impedance  
10 kOhm balanced  
Input level for 100 dB SPL  
output @ 1 m  
Variable from +12 to –6 dBu  
CROSSOVER SECTION  
7060B  
7070A  
7071A  
Subsonic filter  
(18 dB/octave) below  
19 Hz  
85 Hz  
19 Hz  
19 Hz  
OUTPUT SECTION  
Crossover frequency,  
(sub/main channels)  
7060B  
7070A  
7071A  
LFE cutoff Hz  
85 Hz/120 Hz selectable  
Output connector XLR male  
pin 1  
pin 2  
pin 3  
gnd  
+
Crossover slopes  
Lowpass  
36 dB/octave  
12 dB/octave  
Highpass  
Remote LED connector (RJ11)  
Main monitor Out gain  
Sum Out gain  
Remote LED for Power/Overload+Bypass and LFE +10 dB  
Midband rejection >400 Hz  
≥ 50 dB  
0 dB  
0 dB  
Bass Roll-Off control operating  
range in 2 dB steps  
From 0 to –6 dB  
@ 20 Hz  
From 0 to –6 dB  
@ 20 Hz  
From 0 to –6 dB  
@ 20 Hz  
Phase matching control  
in 90° steps  
From 0 to 270  
@ 85 Hz  
CONTROLS  
7060B  
7070A  
7071A  
Input sensitivity  
Bypass  
+12 to –6 dBu for 100 dB @ 1 m  
Bypasses the bass management for the main channels  
LFE bandwidth  
LFE sensitivity  
Redirect  
85 / 120 Hz  
0 / +10 dB  
Redirects LFE channel signal above 85 Hz to center channel  
Changes subwoofer to Sum in mode  
Sum in  
Test tone for phase adjustment  
Bass Roll-Off  
85 Hz  
0/-2 dB/ -4 dB/ -6 dB 0/-2 dB/ -4 dB/ -6 dB 0/-2 dB/ -4 dB/ -6  
@ 20 Hz  
@ 20 Hz  
dB @ 20 Hz  
Phase  
0/90/180/270° @ 85 Hz  
Genelec Document D0032R001b. Copyright Genelec Oy 3.2006. All data subject to change without prior notice  
International enquiries:  
In Sweden please contact  
In the U.S. please contact  
Genelec, Inc., 7 Tech Circle  
Natick, MA 01760  
In China please contact:  
Beijing Genelec Audio Co. Ltd.  
Jianwai SOHO, Tower 12, Room 2306  
39 East 3rd Ring Road  
Genelec Sverige  
Genelec, Olvitie 5  
Ellipsvägen 10B  
FIN-74100, Iisalmi, Finland  
Phone +358 17 83 881  
Fax +358 17 812 267  
Phone +1 508 652 0900  
Fax +1 508 652 0909  
P.O. Box 5521, S-141 05 Huddinge  
Phone +46 8 449 5220  
Fax +46 8 708 7071  
Chaoyang District  
Beijing 100022, China  
Phone +86 0 5869 7915, Fax +86 10 5869 7914  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Edger PE 230 User Manual
ELAN Home Systems Home Theater System THP525LS User Manual
Fisher Plumbing Product 2445 User Manual
Fluke Stereo System 6060B User Manual
Ford Automobile 1998 Ranger User Manual
Frigidaire Air Conditioner FRA054XT7 User Manual
Furuno Radar Detector FRS 1000A User Manual
GE Microwave Oven JE1390 User Manual
GE Video Game Controller Entelli Switch 250 User Manual
Gianni Industries Door EX 827 User Manual