| Operating Manual   Monitoring System   Download from Www.Somanuals.com. All Manuals Search And Download.   Speaker Mounting   Position   Treble tilt   Bass tilt   Bass roll-off   TREBLE TILT   CONTROL   Flat anechoic response   None   None   None   None   -2 dB   -4 dB   None   None   -2 dB   TREBLE TILT   dB   BASS TILT   ALL OFF   USING THE TONE   CONTROLS   dB   +2   0 0 -2   -4   -6   ALL OFF   OFF ON   +2   -2 dB   -4   REFER TO THE OPERATING   MANUAL FOR SUGGESTED   TONE CONTROL SETTINGS.   -2   -4   Free standing in a damped room   BASS TILT   CONTROL   MUTE   FOR ACCURATE   4kHz   20kHz   20Hz   600Hz   OPERATION ONLY ONE   SWITCH IN EACH TONE   CONTROL GROUP SHOULD   Free standing in a   reverberant room   OFF ON   -2   -4 dB   -6   MUTE   BE ON AT   A TIME.   BASS ROLL-OFF   CONTROL   OFF ON   FOR   A FLAT FREE FIELD   BASS ROLL-OFF   dB   -2   -4 dB   -6   -8   RESPONSE SET ALL TONE   CONTROLS TO OFF.   ALL OFF   0 Near field or console bridge   In a corner   None   None   -4 dB   -4 dB   -4 dB   -4 dB   +4   +6   -2   -4   -6   -8   INPUT SENSITIVITY   REQUIRED FOR 100dB   SPL@1m. REFER TO   OPERATING MANUAL   FOR MAXIMUM SPL.   +2   0 INPUT SENSITIVITY   CONTROL   dBu   CAL POSITION   -6   -2   ALL CONTROLS   INPUT SENSITIVITY   : OFF   -6dBu   -4   20Hz   100Hz   : INPUT SENSITIVITY   2 INPUT   CONNECTOR   PIN   PIN   PIN   1 2 3 = = = GROUND   3 Table 1. Suggested tone control settings in some typical situations   + - INPUT   INPUT   1 SIGNAL INPUT   MAINS VOLTAGE   SELECTOR   MAINS   VOLTAGE   SELECTOR   (WHERE   APPLICABLE)   MAINS INPUT   50 60 Hz   150 Watts   115 230   / / V ˜ GENELECR   MAINS CONNECTOR   MAINS SWITCH   1031A BI-AMPLIFIED MONITORING SYSTEM   MAGNETICALLY SHIELDED   MADE IN FINLAND   f ON   SERIAL   Cable   NUMBER   ELECTRIC SHOCK HAZARD!   WARNING   IT IS FORBIDDEN TO UNDO ANY SCREWS ON THIS EQUIPMENT. SERVICING AND ADJUSTMENT   MUST ONLY BE CARRIED OUT BY QUALIFIED SERVICE PERSONNEL.   NEVER OPERATE THIS EQUIPMENT WITHOUT   A PROPER EARTHED MAINS CONNECTION.   DISCONNECT THE MAINS INPUT BEFORE REPLACING THE FUSE.   Screen   ENSURE THAT THE CORRECT VOLTAGE AND APPROPRIATE FUSE ARE SELECTED BEFORE   CONNECTING TO THE MAINS SUPPLY.   RCA   (Source)   XLR   (Speaker)   THIS EQUIPMENT IS CAPABLE OF PRODUCING SOUND PRESSURE LEVELS IN EXCESS OF 85dB   WHICH MAY CAUSE PERMANENT HEARING DAMAGE.   290 mm   320 mm   Figure 2. Location of the acoustic axis   Figure 3. RCA to XLR cable   Figure 1. Amplifier panel layout of the 1031A   the three tone control switch groups ‘treble   tilt’, ‘bass tilt’ and ‘bass roll-off’ on the rear   panel of the amplifier. The factory settings   for these controls are ‘All Off’ to give a flat   anechoic response. See Table 1 for sug-   gested tone control settings. Figure 5 shows   the effect of the controls on the anechoic   response. Always start adjustment by setting   all switches to ‘OFF’ position. Then set only   one switch to the ’ON’ position to select the   response curve needed. If more than one   switch is set to ‘ON’ (within one switch group)   the attenuation value is not accurate.   2. Do not use this product with an   unearthed mains cable as this may lead to   personal injury.   Overload indicators   The speaker is provided with two status   LED's marked 'OVL' and 'ON'. The green   ON-LED when lit indicates that the speaker   is ready for use. The red OVL-LED indicates   that the amplifier is overloaded or the driver   protection circuit is activated. In both cases   reduce the signal level so that the LED stops   blinking. If the OVL-LED stays on constantly it   indicates that the amplifier thermal protection   is activated. Let the amplifier cool down and   check that the ventilation at the rear side of   the speaker is not blocked. There should be   a clearance of more than 4" (10cm) between   speaker rear and any solid surface.   3. To prevent fire or electric shock, do not   expose the unit to water or moisture. Do   not place any objects filled with liquid,   such as vases on the speaker or near it.   4. Note that the amplifier is not   completely disconnected from the AC   mains service unless the mains power   cord is removed from the amplifier or the   mains outlet.   WARNING!   Vertical / horizontal mounting   The speakers are normally delivered set   up for vertical mounting. Horizontal mount-   ing should be avoided due to the increased   likelihood of early reflections that degrade   the the direct sound. If horizontal mounting   is needed the DCW plate may be rotated so   that the Genelec logo remains horizontal by   removing the four corner screws of the DCW   and carefully lifting and turning the DCW.   This equipment is capable of producing sound   pressure levels in excess of 85 dB, which   may cause permanent hearing damage.   Maintenance   Accessories   No user serviceable parts are to be found   within the amplifier unit. Any maintenance   or repair of the 1031A unit should only be   undertaken by qualified service personnel.   Order code   Protective grille   Wall mount   1031-409   1031-404-V/H*   1031-405-V/H*   Floor stand   Safety considerations   Although the 1031A has been designed   in accordance with international safety   standards, to ensure safe operation and to   maintain the instrument under safe operating   conditions, the following warnings and cau-   tions must be observed:   *State the desired speaker orientation   V=vertical or H=horizontal when ordering   these accessories.   Console top mounting   If the 1031A’s are used for near field monitor-   ing, avoid mounting them on the meter bridge   of the console. Instead position the speakers   slightly behind the console by using floor   stands or wall mounts. This prevents the   first reflections from the console surface from   coloring the sound.   Guarantee   This product is supplied with one year guar-   antee against manufacturing faults or defects   that might alter the performance of the 1031A   unit. Refer to supplier for full sales and guar-   antee terms.   1. Servicing and adjustment must only   be performed by qualified service   personnel. The amplifier’s rear panel must   not be opened.   Download from Www.Somanuals.com. All Manuals Search And Download.   1031A Operating Manual   AUDIO PRECISION 1031anec LEVEL(dBr) vs FREQ(Hz)   100   07 SEP 93 11:21:58   AUDIO PRECISION 1031anec LEVEL(dBr) vs FREQ(Hz)   110   07 SEP 93 10:04:11   95   105   100   95   0°   90   15°   85   BASS TILT   90   TREBLE TILT   80   30°   45°   75   85   80   70   65 100   60 95   90   75   BASS ROLL-OFF   70   65   60   20k   20   100   1k   10k   20k   1k   10k   100   20   Figure 4. The upper curve group shows the horizontal directivity   Figure 5. The curves show the effect of the bass tilt, treble tilt and   bass roll-off controls on the free field response.   characteristics of the 1031A in vertical configuration measured at 1 m.   The lower curve is a 1/3 octave band power response, measured in an   IEC approved reverberation chamber.   SYSTEM SPECIFICATIONS   CROSSOVER SECTION   AMPLIFIER SECTION   Input connector XLR female:   pin 1 gnd   pin 2 +   pin 3 -   Bass amplifier short term output power with a   8 Ohm load: 120 W   Lower cut-off frequency, -3 dB:   Upper cut-off frequency, -3 dB:   < 47 Hz   > 22 kHz   Treble amplifier short term output power with an   8 Ohm load: 120 W   Free field frequency response of system:   48 Hz - 22 kHz (± 2 dB)   Input impedance:   10 kOhm balanced   Input level for 100 dB SPL output @ 1m:   variable from +6 to -6 dBu   Maximum short term sine wave acoustic output on   axis in half space, averaged from 100 Hz to 3 kHz:   Long term output power is limited by driver unit   protection circuitry.   @ 1m 110 dB SPL   @ 0.5m > 116 dB SPL   Input level for maximum short term sine wave output   of 110 dB SPL @ 1m:   Amplifier system distortion at nominal output:   THD   < 0.05%   < 0.05%   < 0.05%   < 0.05%   variable from +16 to +4 dBu   SMPTE-IM   CCIF-IM   DIM 100   Maximum long term RMS acoustic output in same   conditions with IEC weighted noise (limited by   driver unit protection circuit):   Subsonic filter below 45 Hz :   Ultrasonic filter above 25 kHz:   18 dB/octave   12 dB/octave   @ 1m > 101 dB SPL   @ 0.5m > 107 dB SPL   Signal to Noise ratio, referred to full output:   Crossover frequency, Bass/Treble:   Crossover acoustical slopes:   2.2 kHz   24 dB/octave   Bass   Treble   > 100 dB   > 100 dB   Maximum peak acoustic output per pair above   console top, @ 1 m from the engineer with music   Treble tilt control operating range in 2 dB steps:   from +2 to -4 dB & MUTE   Mains voltage:   230, 100/200 or 115/230V   according to region   material:   > 120 dB   Self generated noise level in free field @ 1m   on axis: < 10 dB (A-weighted)   Bass roll-off control operating range in 2 dB steps:   from 0 to -8 dB @ 40 Hz   Voltage operating range:   ±10%   Power consumption: Idle   30 VA   160 VA   Harmonic distortion at 90 dB SPL @ 1m on axis:   Bass tilt control operating range in 2 dB steps:   from 0 to -6 dB @ 80 Hz   & MUTE   Full output   Freq:   50...100 Hz   > 100 Hz   < 3%   < 0.5%   Drivers:   Bass 210 mm (8") cone   Treble 19 mm (3/4") metal dome   Both drivers are magnetically shielded.   The 'CAL' position is with all tone controls set to 'off'   and the input sensitivity control to maximum (fully   clockwise).   Weight:   12,7 kg (28 lb)   Dimensions:   Height 393 mm (15 1/2")   Width   250 mm ( 9 7/8")   Depth 290 mm (11 7/16")   Genelec Document D1031AR001 Copyright Genelec Oy 6.2003. All data subject to change without prior notice   International enquiries:   In the U.S. please contact:   Genelec, Inc., 7 Tech Circle   Natick, MA 01760, USA   Phone +1 508 652 0900   Fax +1 508 652 0909   In China please contact:   Genelec, Olvitie 5   Genelec China Representative Office   Soho New Town, 88 Jianguo Road   D-1504, Chaoyang District   Beijing 100022, China   FIN-74100, Iisalmi, Finland   Phone +358 17 83881   Fax +358 17 812 267   Email [email protected]   Phone +86 10 8580 2180   Email [email protected]   Fax +86 10 8580 2181   Download from Www.Somanuals.com. All Manuals Search And Download.   |