®
GARDENA
Art. 7854
D
Gebrauchsanweisung
Schwimmpumpe SP 900, 12 V
GB Operating Instructions
Floating Pump SP 900, 12 V
F
Mode d’emploi
Pompe flottante SP 900, 12 V
NL Gebruiksaanwijzing
Drijvende vijverpomp SP 900, 12 V
S
I
Bruksanvisning
Flytpump SP 900, 12 V
Istruzioni per l’uso
Pompa galleggiante SP 900, 12 V
E
Manual de instrucciones
Bomba flotante SP 900, 12 V
DK Brugsanvisning
Flydepumpe SP 900, 12 V
Download from Www.Somanuals.com. All Manuals Search And Download.
G
G
GARDENA Floating Pump SP 900, 12V
Check line voltage
Check line voltage. Data indicated on the type plate must match
technical data of the mains supply.
Do not operate pump
when there are people
in the water
The pump must not be operated when there are people in the
water.
Welcome to GARDENA aquamotion ...
Please read these operating instructions carefully and observe
the notes given.
Use the instructions to familiarise yourself with the equipment,
the operating controls, their correct use, and the notes on safety.
Swimming pools
and garden ponds
Swimming pools and garden ponds should be designed accord-
ing to international and national design regulations. Please
consult a professional electrician.
For safety reasons, children under 16 as well as persons not
familiar with these operating instructions should not use this
pump.
Do not use power cable
to carry the pump
Do not use the power cable to carry the pump or to pull the plug
out of the socket. Protect the power cable from heat, oil and
sharp edges.
Disconnect plug
Please unplug the pump after operation and before carrying out
any maintenance works.
Keep these operating instructions in a safe place.
Temperature of the liquid
used
The temperature of the liquid used must not be below 4°C or
above 35°C.
The Applications Range of Your Pump
Wear and reduced
output
Sand and other abrasive substances in the liquid cause in-
creased wear and reduce the output of the pump.
GARDENA Floating Pumps have been designed for private use.
They are not designed for operating watering tools and systems.
The pumps may be used indoors as well as outdoors.
Intended purpose
Caution!
12 V low voltage
GARDENA pumps and plug connections have been designed
exclusively for the use with 12 V low voltage. When connected
to 230 V your life is at risk! Operate the pump only with the
delivered transformer.
A GARDENA Floating Pumps have not been designed for con-
stant use in the industrial sector. Corrosive, easily combustible,
aggressive or explosive substances (e.g. petrol, petroleum, nitro
thinner) as well as salt-water or food / drinking water must not
be pumped.
Attention
Do not expose the
transformer to sunlight
Do not expose the transformer to direct sunlight.
Positioning the trans-
former
Ensure that the transformer is positioned in a place safe from
flooding and at least 2 m away from the edge of the pond.
Observe local noise
Please observe the local noise prevention regulations.
prevention regulations
A
For Your Safety
Applications:
Operating the Pump
The transformer should be operated via a residual current de-
vice with a residual current rating of ≤ 30 mA (DIN VDE 0100-
702 and 0100-738). Please ask your electrician for his advice.
Examples – System Extensions – Product Recommendations
Water jets for
26.5 mm (G 3/4) thread
connections
➔ Example for application:
Water jets may be integrated into water features.
Mains power cables
For Austria
Mains power cables should not have a smaller cross-section
than a rubber sheathed cable of the designation H05 RNF.
Extension cables must meet the requirements of DIN VDE 0620.
➔ Products:
GARDENA Cascade
GARDENA Water Bell
GARDENA Waterfall
GARDENA Cascade, Rotating
Art. No. 7814*
Art. No. 7816
Art. No. 7822
Art. No. 7823
In Austria power cables should correspond to ÖVE-EM 42,
T2 (2000)/1979 § 22 according to § 2022.1. According to this
standard pumps used in swimming pools and ponds should
only be operated via an isolating transformer. Please contact
your electrician.
* contained in delivery volume
For Switzerland
Visual check
In Switzerland mobile appliances which are used outdoors,
must be connected via a residual-current device.
Remote control
➔ Application:
For operating water jets from the comfort of your patio
or your living room.
Before operating the pump, look to see if there is any damage
of the pump (esp. regarding power cable and plug). A damaged
pump must not be used. In case of damage, please have the
pump checked by our GARDENA Service Centre or by an
authorised electrician.
➔ Product:
GARDENA Remote Control Set
GARDENA Remote Control Socket Art. No. 7875
Art. No. 7874
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
G
G
How to clean:
Pull the plug connections out of the transformer and dis-
.
.
Information
Always unplug the pump first before working on it.
Before assembling system extensions first unscrew the pre-
assembled cascade of the pump and then screw one of the
water jets on again.
.
connect it!
.
Remove the pump as a whole from the water and use a water
jet and a soft brush to clean it.
➔ Take care that all outlets are free of dirt.
If there are deposits of dirt inside the pump then dismantle the
casing (➔ see „Dismantling”) and carefully clean the interior
fittings with water.
.
Follow the Safety and Assembly Information attached to the
operating instructions.
.
Operation
Information: Do not use any hard objects or strong detergents!
.
.
Put the pump into the water and arrange excess cabling below
the pump into a ring. This prevents the pump from floating to
the edge of the pond.
Blocked feed impeller
If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).
Positioning the pump
If the pump does not float level on the water, then it will need
to be balanced.
1. Dismantle the pump as described in the paragraph
“Dismantling”.
Dismantling
2. Use the knife supplied to carefully cut off
a section of the float (white styrofoam
ring). The right balance can be found by
turning the float.
The pump must be able to float freely in the water.
The water should be at least 20 cm deep.
Pay attention to
minimum water depth
1. Pull the plug connections out of the transformer and dis-
connect it!
2. Remove the pump from the water.
3. Separate the upper part of the pump from the lower part using
a coin or a broad screwdriver.
Put the plug connection into a free socket of the transformer
and connect the power cable of the transformer with a 230 V AC
socket.
Starting the pump
4. Screw off the fountain top.
5. Loosen both screws in the upper part next to pump and
remove the cover.
A Caution! Pump will start running immediately!
6. Unscrew the nut using a spanner.
7. Remove the pump.
8. Turn the pump casing to the left to the limit stop and then pull it
straight forwards and remove it! Do not tilt!
9. Pull the feed impeller out of the motor casing.
Avoid dry operation of the pump as dry running will produce
undesirable heat and destroy the pump.
Avoid dry operation
Care Instructions
Delivery head too low
and/or noisy operation
.
Take care that the pump is always completely submerged in water.
A lack of water can cause the feed impeller to turn in the wrong
direction.
Then assemble all the fittings reversing the order and direction
in which they were dismantled. Please take care that the seal
ring is properly re-fitted.
➔ Remedy:
➔ Make sure while assembling that you attach the pump casing
with the pressure joint being cated, press it firmly and then
turn it straight to the right.
Disconnect the plugs and fill the pump with water. Then connect
the plugs again.
Cleaning the filter tank
The lower part of the pump must be completely free from dirt
particles i.e. all filter outlets must be open. If they are obstructed
by dirt, they should be cleaned as follows:
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
G
G
Storage
EU Certificate of Conformity
A The pump should be stored out of the reach of children.
The undersigned
Where to store
1. Remove the pump from the pond and store away from frost
before the first frost sets in.
2. Clean and check the pump carefully.
3. Store the pump in a container filled with water.
The mains plug must not be submerged.
GARDENA Kress + Kastner GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm
hereby certifies that, when leaving our factory, the unit indicated below is in accordance with the
harmonised EU guidelines, EU standards of safety and product specific standards.
This certificate becomes void if the unit is modified without our approval.
Description of the unit:
Floating Pump
EU directives:
Year of CE marking:
1999
Machinery Directive 98/37/EC
Electromagnetic Compatibility
89/336/EC
Low Voltage Directive
73/23/EC
Information
Type:
SP 900, 12 V
Complaints/Repairs
Ulm, 01.06.1999
If you have any problems with your Floating Pump, please con-
tact our Service or return the defective unit together with a short
description of the problem postage paid to one of the GARDENA
Service Centres listed on the back of these operating instructions.
Art. No.:
7954
Directive 93/68/EC
Harmonised
European standards:
EN 292-1
EN 292-2
EN 60335-1
Thomas Heinl
Technical Dept. Manager
Product liability
We expressly point out that, in accordance with the product
liability law, we are not liable for any damage caused by our
units if it is due to improper repair or if parts exchanged are not
original GARDENA parts or parts approved by us, and, if the
repairs were not carried out by a GARDENA Service Centre or
an authorised specialist. The same applies to spare parts and
accessories.
EN 60335-2-41
Guarantee
Technical Data
GARDENA guarantees this
product for 3 years (from date
of purchase). This guarantee
covers all serious defects
of the unit that can be proved
to be material or manufacturing
faults. Under warranty we will
either replace the unit or repair
it free of charge if the following
conditions apply:
ments of the operating in-
structions. Neither the pur-
chaser nor a non-authorised
third party have attempted
to repair the unit.
In the event of a fault, please
return the faulty unit together
with the receipt and a descrip-
tion of the fault, with postage
paid to the address of the
Service Centre on the back of
these operating instructions.
Type
SP 900, 12V
Art. No.
7854
Rated power
Flow
Max. delivery head
Max. submersion depth
Power cable
10 W
15 l/min
1.7 m
1.0 m
10 m H05 RNF
26.5 mm (G 3/4) male thread
35°C
12 V
Parts subject to wear (e.g.
feed impeller) are excluded
from this guarantee.
Fitting
This manufacturer’s guarantee
does not affect the user’s exist-
ing warranty claims against the
dealer/seller.
.
The unit must have been
Max. media temperature
Mains voltage
Frequency
handled properly and in
keeping with the require-
50 Hz AC
1)
Noise level LWA
48 dB(A)
1) Measuring method according to EN 60335-1
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Deutschland
GARDENA Kress + Kastner GmbH
GARDENA Service
Hans-Lorenser-Straße 40
D-89079 Ulm
Produktfragen: (0731) 490-123
Reparaturen: (0731) 490-290
Finland
Norway
Habitec Oy
GARDENA Norge A/S
Postboks 214
2013 Skjetten
Martinkyläntie 52
01720 Vantaa
France
Poland
GARDENA France
Service Après-Vente
BP 50080
GARDENA Polska Sp. z o.o.
Szymanów 9 d
Argentina
05-532 Baniocha
Argensem S.A.
95948 ROISSY CDG Cedex
Portugal
Venezuela 1075
Great Britain
MARKT (Portugal), Lda.
Recta da Granja do Marquês
Edif. GARDENA
(1618) El Talar - Buenos Aires
GARDENA UK Ltd.
27-28 Brenkley Way
Blezard Business Park
Seaton Burn
Australia
NYLEX Corporation Ltd.
25-29 Nepean Highway
P.O. Box 68
Algueirão
2725-596 Mem Martins
Newcastle upon Tyne
NE13 6DS
Russia / Россия
АО АМИДА ТТЦ
Mentone, Victoria 3194
Austria
Greece
ул. Моcфилмовcкая 66
117330 Моcква
GARDENA Österreich Ges. m.b.H. Agrokip G. Psomadopoulos & Co.
Stettnerweg 11-15
2100 Korneuburg
20, Lykourgou str.
Kallithea - Athens
Singapore
Variware
Belgium
Hungary
Holland Road Shopping Centre
227-A 1st Fl., Unit 29
Holland Avenue
Singapore 1027
MARKT (Belgium) NV/SA
Sterrebeekstraat 163
1930 Zaventem
GARDENA Magyarország Kft.
Késmárk utca 22
1158 Budapest
Brazil
Iceland
Heimilistaeki hf
Saetun 8
P.O. Box 5340
125 Reykjavik
Slowenia / Croatia
Silk d.o.o. Trgovina
Brodišče 15
M. Cassab
Av. das Nações Unidas, 20.882
Santo Amaro, CEP 04795-000
São Paulo - S.P.
1236 Trzin
South Africa
Bulgaria / България
ДЕНЕКС ООД
бул. „Черни връх“ 43
София 1407
Republic of Ireland
Michael McLoughlin & Sons
Hardware Limited
Long Mile Road
GARDENA South Africa (Pty.) Ltd.
P.O. Box 11534
Vorna Valley 1686
Spain
Dublin 12
Canada
ANMI Andreu y Miriam S.A.
Calle Pere IV, 111
08018 Barcelona
GARDENA Canada Ltd.
100, Summerlea Road
Brampton, Ontario
Canada L6T 4X3
Italy
GARDENA Italia S.r.l.
Via Donizetti 22
20020 Lainate (Mi)
Sweden
GARDENA Svenska AB
Box 9003
Chile
Japan
Antonio Martinic Y CIA. LTDA.
Gilberto Fuenzalida 185 Loc.
Las Condes - Santiago de Chile
KAKUDAI Mfg. Co. Ltd.
1-4-4, Itachibori Nishi-ku
Osaka 550
20039 Malmö
Switzerland
GARDENA Kress + Kastner AG
Bitziberg 1
Costa Rica
Luxembourg
Magasins Jules Neuberg
Grand Rue 30
Case Postale No. 12
Luxembourg 2010
Compania Exim
Euroiberoamericana S.A.
350 Sur del Automercado
Los Yoses
8184 Bachenbülach
Ukraine / Украина
АОЗТ АЛЬЦЕСТ
ул. Гайдара 50
г. Киев 01033
San Pedro
Netherlands
Cyprus
MARKT (Holland) BV
Postbus 219
Turkey
FARMOKIPIKI LTD
P.O. Box 7098
74, Digeni Akrita Ave.
1641 Nicosia
Dost Diþ Ticaret Mümessillik A.Þ.
Yeþilbaðlar Mah. Baþkent
Cad. No. 26
Pendik - Ýstanbul
USA
GARDENA
1380 AE Weesp
Neth. Antilles
Jonka Enterprises N.V.
Sta. Rosa Weg 196
P.O. Box 8200
Czech Republic
GARDENA spol. s.r.o.
Ripská 20
Curaçao
3085 Shawnee Drive
Winchester, VA 22604
62700 Brno
New Zealand
NYLEX New Zealand Limited
Private Bag 94001
South Auckland Mail Centre
10 Offenhauser Drive
East Tamaki, Manukau
Denmark
GARDENA Danmark A/S
Naverland 8
7854-20.960.03/0001
GARDENA Kress + Kastner GmbH
Postfach 27 47, D-89070 Ulm
http://www.gardena.de
2600 Glostrup
Download from Www.Somanuals.com. All Manuals Search And Download.
|