Access Control
Controllers & Processors
Overview
Standard Features
The ACUXL16 Networked Intelligent Controller features state-of-
the-art technology, and provides both the flexibility and reliability
needed to meet today’s complex access control and alarm monitor-
ing requirements. Using a sophisticated, high speed embedded 32-
bit, 90 MHz microprocessor and high-capacity 16 MB memory, the
ACUXL16 controls up to 16 readers. Each ACUXL16 supports large
card populations of up to 250,000 and has the ability to communi-
cate over LAN, fiber, dial-up or RS-485 networks.
•
Supports up to 16 readers and associated interfaces through
two RS-485 communication ports.
•
Supports magnetic stripe, Wiegand, barium ferrite, barcode,
proximity, biometric and smart card technologies. Each reader
is user-configurable (card only, card & keypad, or keypad only).
Variable card formats, multiple site codes and company codes
are supported.
•
Alarm Monitoring: The ACUXL16 includes 12 fully supervised six-
state alarm inputs which provide false alarm filtering and utilize
digital signal processing. Any combination of up to eight remote
interface modules can be connected in place of reader inter-
faces for additional capacity, including Relay Output Modules
(described below), and Alarm Input Modules (RIM) which provide
16 additional six-state supervised alarm inputs with tri-color LED
status indicators (each).
The ACUXL16 interfaces with all GE Security Diamond II and Sap-
phire Pro servers, and offers the widest range of features and
flexibility, with a design focus on reliability, durability, and ease of
installation and maintenance.
The ACUXL16 panel incorporates two external device ports, each
capable of controlling eight readers/interfaces, which are multi-
dropped using an RS-485 interface. Input and output capacity can
be expanded — see the ACU Remote Modules datasheet for details.
Each panel includes a parallel printer port to provide local, real-time
printing of transactions.
•
•
Each alarm input allows detection/reporting of circuit trouble
conditions: loop resistance too low (short circuit), loop resistance
too high (open circuit), loop voltage out of range (circuit fault),
and a portion of loop grounded (ground fault).
The ACUXL16 includes 12 SPDT relay outputs that are configu-
rable for control of locking devices, activation of local annuncia-
tors and other output applications. Each SPDT relay is rated at
2.0 A, 30 VDC, and includes an LED status indicator. Any combi-
nation of up to eight remote interface modules can be connect-
ed in place of reader interfaces for additional capacity, includ-
ing Alarm Input Modules (described above), and Relay Output
Modules (RRM) which provide 16 additional output relays (each).
Networked
Intelligent
Controller
ACUXL16
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuration
Cable # Description
Belden Cable Number ( or equal)
Max. Distance
Communication (RS-485)
Power (24 VDC)
Exit Request Button / Sensor
Input
#9842 or Alpha #6222C, 24 AWG, 2-pair, braid overall shield AND #9409 or
Alpha #1897C, 18 AWG, 2-conductor/unshielded
4,000’ (1,220 m) 4,000’
(1,220 m)
1
2
#9407-22 AWG, 2-conductor (unshielded)
1,000’ (305 m)
Door Lock Control from
Controller or RRE
Standard Reader
3
4
#9409-18 AWG, 2-conductor (unshielded)
1,000’ (305 m)
varies
Varies with type of reader/keypad. See manufacturers instructions.
Controller to Host
Communication or other
ACU panels OR Controller to 4-pair (unshielded)
10/100 Hub Communication
#9842 or Alpha #6222C, 24 AWG, 2-pair/braid overall shield #1583A-24 AWG,
4,000’ (1,220 m) 328’
(100 m)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
North America
Specifications
T (561) 998-6100
T 888-GE-SECURITY
888-(437-3287)
F 561 998 6224
Height: 20.12” (51.1 cm)
Width: 16.50” (41.9 cm)
Depth: 5.00” (12.7 cm)
Dimensions
4 amp units: 44 lbs (20 kg)
8 amp units: 62 lbs (28.1 kg)
4 amp units: 32 lbs (14.5 kg)
8 amp units: 38 lbs (17.2 kg)
Weight (with batteries)
Asia
T 852-2907-8108
F 852-2142-5063
Weight (without batteries)
Maximum: +65 C (+150 F)
Minimum: 0 C (+32 F)
Humidity: 0 to 95% relative
Australia
T 61-3-9259-4700
F 61-3-9259-4799
Environmental
120/240 VAC (cut current in half for 240 VAC),
50/60 Hz, DC standby battery backup
Maximum: 1.0 amps, 120 watts
Maximum: 2.0 amps, 240 watts
Plug-in dial-up modem
Gel-cell batteries for UPS
Europe
T 32-2-725-11-20
F 32-2-721-86-13
Power
4 amp power supply
8 amp power supply
Latin America
T 305-593-4301
F 305-593-4300
Options
©2006 General Electric Company
All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
|