GE Plumbing Product GNUL30B User Manual

GE Appliances  
Water Filtration System  
Owner’s Manual  
and Installation  
GNUL30B  
Faucet & Base  
GNUT05B  
GXEM01B  
GNUT05B and GNUL30B are  
Tested and Certified by NSF  
International against ANSI/NSF  
Standard 42 for Particulate  
Reduction Class I, Chlorine  
Reduction Class I and Taste  
and Odor Reduction.  
GNUL30B is Tested and Certified  
by NSF International against  
ANSI/NSF Standard 53 for Cyst,  
Turbidity and Lead Reduction.  
GXEM01B is Tested and Certified  
by NSF International against  
ANSI/NSF Standard 42 for  
materials and structural integrity  
requirements only.  
Part No. 215C1044P006-1 Pub. No. 49-50023-2 4-99 JR  
7205716  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INFORMATION.  
READ ALL INSTRUCTIONS BEFORE USING.  
SafeyIructions  
For your safety, the information in this manual must be followed to minimize the risk of  
WARNING! property damage or personal injury.  
SAFETY PRECAUTIONS  
Check with your local public works department  
WARNING: Do not use with water that is  
microbiologically unsafe or of unknown quality  
without adequate disinfection before or after  
the system. Systems certified for cyst reduction  
may be used on disinfected water that may contain  
filterable cysts.  
OpeagIructions  
for plumbing codes. You must follow these  
guidelines as you install the Water Filtration  
system.  
Use the Water Filtration system on a potable,  
safe-to-drink, home COLD water supply only.  
The filter cartridges will not purify the water,  
or make it safe to drink.  
Do not use on a hot water supply (100°F. max.)  
.
laIructions  
PROPER INSTALLATION  
This Water Filtration system must be properly installed and located in accordance with the Installation  
Instructions before it is used.  
Install or store where it will not be exposed to  
Your Water Filtration system will withstand up to  
temperatures below freezing or exposed to any  
type of weather. Water freezing in the system  
will damage it. Do not attempt to treat water  
over 100°F.  
125 pounds per square inch (psi) water pressure.  
If your house water supply pressure is higher than  
100 psi, install a pressure reducing valve before  
installing the Water Filtration system.  
WARNING: Discard all unused and packaging  
material after installation. Small parts remaining  
after installation could be a choke hazard.  
T
rubleshotingT  
Read and follow this Safety Information carefully.  
SAVE THESE INSTRUCTIONS  
ips  
CustomSrvice  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Specification guidelines.  
Many bad tastes and/or odors are removed  
NOTE: Small amounts of hydrogen sulfide  
(noticeable as “rotten egg” odor) may be  
reduced by taste and odor filters for a short  
time, but the carbon media is quickly  
exhausted. Other water conditioning  
equipment is usually required for the  
continuous treatment of hydrogen sulfide.  
from water using activated carbon filter  
cartridges. They are most often used to  
remove a chlorine taste and odor. They can  
also reduce other undesirable elements  
from drinking water supplies, such as  
organic chemical contaminants and lead.  
SafeyIructions  
The Water Filtration system uses two filter cartridges.  
Filter I. FXUSB—a sediment filter cartridge  
Filter IIa. FXUTB—(Optional filter choices)  
a taste and odor filter cartridge  
Reduces dirt, rust and sediment  
6000 gallons  
Reduces unpleasant tastes and odors  
Reduces 99.5% chlorine  
1 micron, carbon block  
IIb. FXULB—a lead/cyst filter cartridge  
1250 gallons  
OpeagIructions  
Reduces 95.7% lead  
Reduces 99.5% chlorine  
Reduces 99.98% filterable cysts (such as  
cryptosporidium and giardia)  
Reduces turbidity by 99.7%  
Absolute (>99.9%) one-micron carbon  
block  
Minimum - Maximum Supply Water Pressure—40–125 pounds per square inch (psi)  
Minimum - Maximum Supply Water Temperature—40–100°F.  
Inlet - Outlet—3/8NPT, fittings and tubing included  
laIructions  
Maximum Filtered Water Flow—0.6 gpm  
ips  
Depending on the treatment needed for a specific water supply, the water filtration system can be  
customized using any combination of the preceding filter cartridges.  
rubleshotingT  
T
CustomSrvice  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SafeyIructions  
About the water filtration system.  
Using the Water Filtration System and About the Filter Cartridge  
The countertop faucet dispenses filtered drinking  
water when opened. It has a hand-operated, spring-  
loaded closed lever to prevent waste. You can keep  
the faucet open by pushing upward on the lever to  
lock it against the faucet spout.  
Filtered water faucet  
Lock  
open  
Open  
Filter Cartridge Life—Several variables determine  
how long the cartridges will last in your Water  
Filtration system. These include:  
OpeagIructions  
How much water you use.  
1
How much sediment, taste and/or odor, lead, or  
2 other unwanted substance, is in the water.  
No matter which Water Filtration system you have,  
you should replace the cartridges every six months,  
when indicated by the electronic indicator light on  
the base. In extremely poor water supplies, you may  
notice the return of the unwanted substance in  
your water before the six months are up. In this  
case the cartridges should be replaced  
immediately. If the system is also for lead or  
chemical contaminant removal, it is MORE  
IMPORTANT to replace the cartridges at least every  
six months.  
laIructions  
NOTE: If the water supply contains high amounts of  
sediments, the carbon filters may plug with them,  
reducing filtered water flow to the system faucet.  
Cartridge replacement is needed to restore flow.  
Electronic Indicator Light—The electronic indicator  
light on the base of the faucet is a six month timer  
that shows you when to replace the filter cartridges.  
When the battery pack is first installed, the  
indicator light will light briefly to show that the  
electronics are operating. If this does not happen,  
the batteries may be installed backwards or the  
leadwires are not connected.  
T
rubleshotingT  
Indicator light  
After about six months, the indicator light begins  
to flash. It is time to replace the filter cartridges.  
When replacing the filter cartridges, also replace  
the batteries in the battery pack. Two “AA”  
batteries are required.  
ips  
CustomSrvice  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
About the water filtration system.  
Filter Cartridge Replacement  
CAUTION: Never remove the sumps when water pressure is in the Water Filtration system.  
Close the water supply/saddle valve to the filter. (See Fig. 1 in the Installation Overview section  
for location of the saddle valve.) Open the filtered water faucet.  
1
Remove the sump, using the sump wrench tool provided, from the filter head by rotating the  
2 sump as shown in the below illustration. Be careful, the sump may be full of water. Be sure to  
SafeyIructions  
keep the large o-ring seal.  
Bracket  
Head  
Cartridge  
O-ring seal  
Sump  
Sump  
TURN SUMP  
TO INSTALL  
Turn sump wrench tool  
provided clockwise  
Label  
TURN SUMP  
TO REMOVE  
OpeagIructions  
Sump  
Filter ΙΙ  
Filter Ι  
If you are replacing a filter cartridge, remove and discard the used filter cartridge.  
3
Be sure the inside of the sump is clean. Thoroughly wash the inside of the sump with hot,  
4 soapy water and rinse.  
Remove the wrapper from the new filter cartridge and insert the filter cartridge in the sump.  
5 Some cartridges fit either way, while others fit only one way. Observe markings on the  
cartridge.  
NOTE: The Water Filtration system uses two different types of filter cartridges. Be sure to  
install them correctly.  
The sediment (FXUSB) filter cartridge should always be placed in the Filter Ι sump.  
laIructions  
Lightly lubricate the o-ring seal in the sump with clean silicone grease. Be sure it is fully  
6 seated in its groove.  
ips  
Hold the sump up to the filter head, aligning the center hole in the cartridge with the  
7 protrusion on the bottom of the head.  
Being careful not to cross-thread, rotate the sump onto the filter head and tighten securely  
8 by hand.  
NOTE: If the sump will not tighten up to the head, you may have the cartridge in upside  
down. Take the cartridge out and check for correct orientation.  
Repeat steps 2 through 8 for the taste/odor (FXUTB) or lead/cyst (FXULB) filter cartridge in the  
Filter ΙΙ sump.  
9
rubleshotingT  
T
Turn on the filtered water faucet. Then, slowly open the water supply/saddle valve and allow  
the filter housing to fill.  
10  
11 Close the filtered water faucet. Then, check for leaks between the sump and the head.  
NOTE: If leaking, turn off the water supply and turn on the filtered water faucet. Disassemble  
the filter and check the o-ring for cuts, flat spots, etc., and sealing surfaces for foreign  
material. Clean the o-ring and lightly lubricate with clean silicone grease. Carefully press  
into the groove in the sump.  
If you are replacing the batteries, remove, properly discard and install two new “AA”  
12  
alkaline batteries in the battery pack. Removing the batteries or momentarily disconnecting  
the leadwires resets the six month electronic timer.  
CustomSrvice  
The filter cartridges contain activated carbon. When new, turn on the filtered water faucet  
6
13  
for ten minutes to flush the system.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SafeyIructions  
Flush Procedure  
Whenever water of unknown quality is passed through the GE Water Filtration system, filter elements  
should be discarded and the filtration system flushed.  
Circumstances that may require flushing the system are:  
Boil-water advisory.  
Flooding of the GE Water Filtration system.  
Long-term non-use.  
OpeagIructions  
The procedure for flushing the GE Water Filtration system is:  
See Filter Cartridge Replacement section and follow steps 1, 2, 3, and 4.  
1
Next, reinstall the sumps (without the filter elements), turn water on, and flush water through the  
2 faucet for one minute.  
Then, turn water off, remove sumps, empty water out of sumps and install new filter elements.  
3
Follow steps 6–9 in the Filter Cartridge Replacement section to complete.  
4
laIructions  
T
rubleshotingT  
ips  
CustomSrvice  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation Instructions  
Important Installation Recommendations  
Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.  
Check with your local public works department for plumbing codes. You must follow their guides as you install  
the Water Filtration system.  
Use the Water Filtration system on a potable, safe-to-drink, home COLD water supply only. The filter cartridges will  
not purify water or make unsafe water safe to drink. DO NOT use on HOT water (100° F. max.).  
SafeyIructions  
Protect the Water Filtration system and piping from freezing. Water freezing in the system will damage it.  
Your Water Filtration system will withstand up to 125 psi water pressure. If your house water supply pressure is  
higher than 100 psi during the day (it may reach higher levels at night), install a pressure reducing valve before  
the system.  
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without  
adequate disinfection before or after the system. GNUL30 is certified for cyst reduction and may be used  
on disinfected water that may contain filterable cysts. The water should be tested periodically to verify  
that the system is performing satisfactorily. Small parts remaining after the installation could be a choke  
hazard. Discard safely.  
OpeagIructions  
Tools and Materials Required for Installation  
Slotted and Phillips screwdrivers  
Contents included with the product:  
Pliers and adjustable jaw wrench  
Water filter assembly, including mounting bracket  
and screws  
Hand or battery powered drill and 1⁄4bit  
(saddle valve installation)  
Product Literature (Owner’s Manual and  
Installation, Product Data Sheet, Owner Product  
Registration Card)  
Electric drill and drill bit to drill 1-1 1⁄4hole  
(type as required) if mounting hole is needed for  
faucet  
Water supply/saddle valve  
Filtered water faucet, for sink or countertop  
mounting including an electronic indicator faucet  
base and battery pack  
CAUTION: To avoid damaging the sink, consult  
a qualified plumber or installer for drilling  
procedures. Special drill bits may be needed  
for porcelain or stainless steel.  
laIructions  
3 8tubing and fittings to make all needed  
connections  
ips  
Sump wrench  
Installation Overview  
Washer  
Adapter  
Nut  
Fig. 1  
Filtered  
water faucet  
Locate the drinking water  
system on the cold water  
supply pipe, under the  
kitchen and/or bathroom  
sink, to filter the cold  
drinking water.  
Sink  
rubleshotingT  
Tubing  
T
Battery pack  
Water out  
Water supply valve  
Cold  
Hot  
Shutoff valve  
Water in  
Mounting  
screw (2)  
NOTE:To change the filter cartridge, you  
must turn off the water. A nearby shutoff  
valve is convenient. Most sinks already have  
shutoff valves on the supply pipes.  
Insert  
Nut  
Filter ΙΙ  
Tubing  
Filter Ι  
CustomSrvice  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SafeyIructions  
Step-by-step installation instructions.  
Feed Water Supply  
Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting. For new  
home installation using standard plumbing fittings, see Fig. 2A below. A typical installation for existing  
homes using the saddle valve is shown in Fig. 2B below.  
A. PREFERRED INSTALLATION  
Turn off the cold water supply.  
Complying with plumbing codes, install a  
1
2 fitting on the cold water pipe to adapt 3⁄8OD  
tubing. A typical connection is shown in Fig. 2A  
(parts not included). Make sure a water supply  
valve is used.  
OpeagIructions  
Preferred water supply connection  
(using compression fitting)  
Fig. 2A.  
Typical location  
Water supply valve  
Ferrule  
Insert  
laIructions  
Cold  
water  
pipe  
Cold  
water  
3⁄8tubing to inlet  
B. OPTIONAL HOME INSTALLATION Where codes permit  
NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not  
permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth  
of Massachusetts.  
T
Turn off the cold water supply  
and attach saddle valve as  
shown in Fig. 2B.  
Close the water supply valve by  
Open the main water supply  
rubleshotingT  
1
2 turning the handle clockwise.  3 valve and several house  
faucets to purge air from the  
system. Close faucets when  
water runs smoothly.  
DANGER: To protect yourself  
from serious injury or fatal  
shock, use a battery powered  
hand drill only to make the  
hole. DO NOT USE AN  
ELECTRIC DRILL.  
ips  
Optional water supply connection (using saddle valve)  
Fig. 2B.  
Pre-drill  
1⁄4hole  
Seal—make sure the  
seal is in place  
CustomSrvice  
Nut (2)—not required if  
Clamp X  
Valve  
holes in clamp are threaded  
Clamp Z  
Washer  
Handle  
Tubing adapter  
Compression nut  
Use to connect the tubing  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Step-by-step installation instructions.  
Electronic Faucet Installation  
Fig. 3A.  
Screw (2)  
Be sure there is room underneath the sink to make the  
needed connections. Select one of the following places to  
install the faucet:  
Faucet  
base  
IN an existing sink spray attachment or soap dispenser  
hole.  
SafeyIructions  
IN a hole to be drilled in the sink top.  
Nut (2)  
IN a hole to be drilled in the countertop, next to  
the sink.  
TOP VIEW  
Fig. 3B.  
NOTE: Looking at Fig. 3D, be sure the faucet base will fit  
flat against the surface at the selected location so the  
gasket will seal. The base may have to be angled sideways  
or diagonally.  
Screw (2)  
Nut (2)  
1-1 1/4dia.  
mounting  
hole in sink or  
countertop  
Faucet  
base  
If drilling is needed, make a 1-1 1⁄4dia. hole. Be  
1
sure to use the proper procedure for drilling porcelain  
Gasket  
or stainless steel. Special drill bits may be needed.  
Looking at Fig. 3A, insert a screw into the NON-  
2
SLOTTED base mounting hole. Turn a flat nut  
ASSEMBLED  
Fig. 3C.  
OpeagIructions  
a few turns onto the screw.  
Position the base gasket over the mounting hole. Set  
3
Spout  
Lever  
the base on the gasket, routing the leadwire through  
the mounting hole. Holding the flat nut under the  
sink with one finger, tighten the screw until just snug.  
Turn the remaining flat nut a few turns onto  
Faucet  
4
the other screw. Position the screw in the slotted base  
mounting hole and tighten until snug. Make sure the  
gasket position is properly aligned and carefully tighten  
both screws until the base is held firmly in place. Do  
not overtighten and break the base.  
Faucet stud  
Assemble the top faucet base and hex nut onto the  
faucet stud (Fig. 3C). Tighten the nut until snug.  
laIructions  
Top faucet base  
5
Insert washer into tubing adapter. Securely tighten to  
6
Hex nut  
Washer  
faucet stud.  
ips  
Feed the length of 3⁄8OD tubing from the bottom,  
up through the faucet base. Connect to the tubing  
adapter as shown in Fig. 3D., tightening the  
compression nut securely.  
7
Tubing  
adapter  
Fig. 3D.  
Remove the short shipping tube and insert the spout  
into the faucet body.  
8
Compression  
nut  
rubleshotingT  
Lower the faucet assembly and lock into place  
on the faucet base.  
T
9
Compression nut  
3/8tubing, (run  
to Filter 2 outlet)  
Faucet base  
CustomSrvice  
Base leadwire connector  
(to battery pack)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SafeyIructions  
Mounting Bracket to Cabinet Wall  
The bracket can be used as a template for marking the location of the mounting screws. When determining  
the location of the bracket make sure you leave 1-1⁄2to 2of free area under the sumps to allow for sump  
removal and enough space on either side to make the tubing connections.  
Make Tubing Connections  
Run the length of 3⁄8tubing, connected to the bottom of faucet, to the filter system outlet, Fig.1 in the  
1 Installation Overview section. Allow enough slack in the tubing to be able to place the system on the floor  
in front of the sink. Measure and cut the end of the tubing square.  
OpeagIructions  
Slide a compression nut onto the end of the tubing and push a tubing insert into the tubing.  
2
Connect the tubing and tighten the compression nuts securely.  
3
Repeat the preceding steps to connect a length of tubing between the filter system inlet and the water  
4 supply/saddle valve, Fig. 1 in the Installation Overview section.  
Fig. 4  
7-9⁄16″  
Tubing  
laIructions  
connector  
Mounting  
bracket  
Mounting  
screws  
Tubing  
connector  
Sump  
Sump  
Filter ΙΙ  
Filter Ι  
T
1-1⁄2to 2″  
rubleshotingT  
Battery Pack Installation and Connection  
In a dry location, within reach of the electronic base 3leadwire, select a place for the battery pack (see  
1
ips  
Fig. 1 on page 8). The battery pack attaches to most surfaces, using the included “sticky-back” Velcro™  
strip.  
The battery pack uses two size “AA” batteries. Check to be sure they are installed correctly. Then,  
2 remove the paper backing on the Velcro™ strip and secure the pack in place.  
CustomSrvice  
Fasten electronic base leadwire and battery pack connector together.  
3
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Step-by-step installation instructions.  
Filter Cartridge Installation or Replacement  
CAUTION: Never remove sumps with water pressure in the Water Filtration system.  
Close the water supply/saddle valve (Fig. 1 and 2A) to the filter. Open the filtered water faucet.  
1
Turn the sump off of the filter head as shown (use the sump wrench provided). Be careful, the sump  
2 is full of water. Locate and save the large o-ring seal. Remove and discard the used filter cartridge.  
SafeyIructions  
Be sure the inside of the sump is clean. Thoroughly wash with hot, soapy water and rinse.  
3
Remove the wrapper and labels from the new filter cartridge and insert the filter cartridge in the sump.  
4 Some cartridges fit either way, while others fit only one way. Observe markings on the end of the cartridge.  
The sediment (FXUSB) filter cartridge should always be placed in the Filter I sump.  
Lightly lubricate the o-ring seal, in the sump, with clean silicone grease. Be sure it is fully seated in its  
5 groove.  
Hold the sump up to the filter head, aligning the center hole in the cartridge with the protrusion on the  
6 bottom of the head.  
NOTE: If the sump will not tighten up to the head, you may have the cartridge in upside down. Take the  
cartridge out and check the markings on the end of the cartridge for correct orientation.  
OpeagIructions  
Being careful not to cross-thread, turn the sump onto the filter head and hand tighten securely (see Fig. 5).  
7
8 Repeat steps 2 through 7 for the taste/odor (FXUTB) or lead/cyst (FXULB) filter cartridge in the Filter ΙΙ sump.  
Open the filtered water faucet. Then, slowly open the water supply/saddle valve and allow the filter  
9 housing to fill.  
10 Close the filtered water faucet. Then, check for leaks between the sump and the head.  
NOTE: If leaking, turn off the water supply and open the filtered water faucet. Then, disassemble the filter  
and check the o-ring for cuts, flat spots, etc., and sealing surfaces for foreign material. Clean the o-ring and  
lubricate with clean silicone grease. Carefully press into the groove in the sump.  
Remove and install two new “AA” alkaline batteries in the battery pack. Removing the batteries or  
momentarily disconnecting the leadwires resets the six month electronic base timer.  
laIructions  
11  
The filter cartridges contain activated carbon. When new, open the filtered water faucet for ten minutes  
to flush the system.  
12  
ips  
Fig. 5  
Bracket  
rubleshotingT  
T
Head  
Cartridge  
Sump  
O-ring seal  
TURN SUMP  
TO INSTALL  
Sump  
Replacement label  
TURN SUMP  
TO REMOVE  
Sump  
Filter ΙΙ  
wrench  
To  
Filter Ι  
loosen  
CustomSrvice  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SafeyIructions  
Before you call for service…  
Troubleshooting Tips  
Save time and money! Review the chart below  
first and you may not need to call for service.  
Problem  
Possible Causes  
What To Do  
Water contains tiny  
black particles  
New filter cartridges contain    
activated carbon, which is a  
harmless black powder.  
Turn on the filtered water faucet and allow these  
harmless carbon particles to purge from the cartridge.  
Turn off the faucet when the water is clear.  
OpeagIructions  
Water has air bubbles  
and is cloudy  
Air in system after installation.  
Will go away after water runs for a while.  
Indicator light on the  
faucet base is flashing  
Six months usage has occurred.  
This is the maximum life of the  
filter cartridges.  
Replace both filter cartridges and batteries in the  
battery pack.  
Indicator light on the  
The faucet base leadwire  
Connect.  
faucet base is not working is not connected to the battery  
pack leadwire.  
laIructions  
Batteries may need to be  
replaced or they may have been  
installed incorrectly.  
Observe orientation markings on the holder and install  
correctly. Replace batteries if they are old.  
Leadwires damaged.  
Inspect and repair as needed.  
Chlorine taste and /or  
odor in the product water  
The filter cartridges are no  
longer removing chlorine  
from the water supply.  
Replace both filter cartridges and batteries in the  
battery pack.  
T
rubleshotingT  
ips  
CustomSrvice  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Notes.  
SafeyIructions  
OpeagIructions  
laIructions  
ips  
rubleshotingT  
T
CustomSrvice  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GE Service Protection Plus  
GE, a name recognized worldwide for quality and dependability, offers you Service  
Protection Plus —comprehensive protection on all your appliances—No Matter  
What Brand!  
Benefits Include:  
Backed by GE  
We’ll Cover Any Appliance.  
Anywhere. Anytime.*  
All brands covered  
Unlimited service calls  
All parts and labor costs included  
No out-of-pocket expenses  
No hidden deductibles  
One 800 number to call  
You will be completely satisfied with our service protection or you may request your money back  
on the remaining value of your contract. No questions asked. It’s that simple.  
Protect your refrigerator, dishwasher, washer and dryer, range, TV, VCR and much more—any brand!  
Plus there’s no extra charge for emergency service and low monthly financing is available. Even icemaker  
coverage and food spoilage protection is offered. You can rest easy knowing that all your valuable  
household products are protected against expensive repairs.  
Place your confidence in GE and call us in the U.S. toll-free at 800-626-2224  
for more information.  
*All brands covered, up to 20 years old, in the continental U.S.  
Cut here  
Please place in envelope and mail to:  
General Electric Company  
Warranty Registration Department  
P.O. Box 34070  
Louisville, KY 40232-4070  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Consumer Product Ownership Registration  
Dear Customer:  
Thank you for purchasing our product and thank you for placing your  
confidence in us. We are proud to have you as a customer!  
Follow these three steps to protect your new appliance investment:  
Complete and mail  
your Consumer  
After mailing  
Read your Owner’s  
Manual carefully.  
It will help you  
operate your new  
appliance properly.  
If you have questions,  
or need more  
the registration  
below, store this  
document in a safe  
place. It contains  
information you  
will need should  
Product Ownership  
Registration today.  
Have the peace of  
mind of knowing we  
can contact you in  
the unlikely event of  
a safety modification.  
you require service.  
information call the  
2 3  
1
Our service number  
is 800-GE-CARES  
(800-432-2737).  
GE Answer Center  
800.626.2000.  
®
Model Number  
Serial Number  
Important: If you did not get a registration card with your product,  
detach and return the form below to ensure that your  
product is registered.  
Cut here  
Consumer Product Ownership Registration  
Model Number  
Serial Number  
Mr. Ms. Mrs. Miss ■  
First  
Name  
Last  
Name  
Street  
Address  
Apt. #  
City  
Zip  
Code  
State  
Date Placed  
In Use  
Month  
Day  
_
Year  
Phone  
Number  
_
GE Appliances  
General Electric Company  
Louisville, Kentucky 40225  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SafeyIructions  
Parts List.  
OpeagIructions  
Saddle Valve  
*
laIructions  
T
rubleshotingT  
ips  
CustomSrvice  
*NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not  
permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth  
of Massachusetts.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
General Electric parts catalog.  
G
N
U
L
3
G
N
U
T
0
G
X
E
M
0
0
5
1
B
0
1
B
0
1
B
0
1
SafeyIructions  
REF. NO.  
0001  
0002  
0003  
0004  
0005  
0006  
0007  
0008  
0009  
0010  
0012  
0014  
0015  
0016  
0017  
0018  
0019  
PART NO.  
PART DESCRIPTION  
SCREW #10-14 X 3/4″  
MOUNTING BRACKET  
NUT 3/8″ ΤUΒΕ  
WS02X10001  
WS28X10010  
WS22X10008  
WS22X10007  
WS02X10003  
WS22X10002  
WS19X10011  
WS03X10001  
WS30X10002  
WS22X10003  
WS07X10008  
WS02X10004  
WS03X10003  
WS03X10002  
WS15X10008  
WS15X10002  
WS10X10001  
WS10X10008  
WS02X10007  
WS10X10002  
WS02X10008  
WS08X10003  
WS06X10001  
FXUTB  
8
1
2
2
2
2
2
2
2
1
1
2
2
2
1
1
1
-
2
1
2
1
1
-
1
1
1
8
1
2
2
2
2
2
2
2
1
1
2
2
2
1
1
-
8
1
2
2
2
2
2
2
2
1
1
2
2
2
1
1
-
1
2
1
2
1
1
-
INSERT 3/8″ ΤUΒΕ  
SCREW #10-14 X 1/4″  
ELBOW 3/8NPT X 3/8″  
HEAD  
O-RING  3-3/8X 3-5/8″  
SUMP  
NIPPLE 3/8NPT X 1-1/2″  
TUBING 3/8X 20 FT–WH  
NUT 3/8″  
OpeagIructions  
ADAPTER TUBING  
WASHER  
SADDLE VALVE /SUPPLY  
FAUCET ASM.  
BASE  FAUCET, TOP  
TOP FAUCET BASE BLACK  
SCREW #6-32 X 1-3/8″  
BASE FAUCET KIT  
NUT  
1
2
1
2
1
1
1
1
-
0020  
0021  
0022  
0023  
0024  
0025  
GASKET FAUCET  
HOLDER BATTERY  
FILTER-TASTE & ODOR  
FILTER-SEDIMENT  
FILTER-LEAD/CYST  
WRENCH SUMP  
FXUSB  
-
-
1
laIructions  
FXULB  
0200  
0999  
WX5X140  
1
49-50023  
PM MANUAL USE & CARE/  
INSTALLATION  
1
1
1
ips  
rubleshotingT  
T
CustomSrvice  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SafeyIructions  
GE Water Filtration System Warranty.  
All warranty service provided by our SmartWater™ Authorized Servicer Network.  
For service, call 800-GE-CARES.  
For The Period Of: GE Will Replace:  
One Year  
Any part of the Water Filtration system (excluding filters) which fails due to a defect in materials or  
From the date of the  
original purchase  
Model GXEM01B  
workmanship. During this limited one-year warranty, GE will also provide, free of charge, all labor  
(does not include service trip to home) to replace the defective part.  
OpeagIructions  
One Year  
Any part of the Water Filtration system (excluding filters) which fails due to a defect in materials or  
workmanship. During this full one-year warranty, GE will also provide, free of charge, all labor  
and in-home service to replace the defective part.  
From the date of the  
original purchase  
Models GNUT05B  
and GNUL30B  
What GE Will Not Cover:  
Service trips to your home to teach you how to use the  
Filter cartridges.  
laIructions  
product.  
Replacement of house fuses or resetting of circuit  
breakers.  
Improper installation.  
Failure of the product if it is abused, misused, or used for  
other than the intended purpose or used commercially.  
Damage to the product caused by accident, fire, floods or  
acts of God.  
Use of this product where water is microbiologically  
unsafe or of unknown quality, without adequate  
disinfection before or after the system. Systems certified  
for cyst reduction may be used on disinfected water that  
may contain filterable cysts.  
Incidental or consequential damage to personal property  
caused by possible defects with this appliance.  
T
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home  
use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.  
rubleshotingT  
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives  
you specific legal rights, and you may also have other rights which vary from state to state. To know what your  
legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.  
ips  
Warrantor: General Electric Company. Louisville, KY 40225  
CustomSrvice  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Service Telephone Numbers.  
GE Answer Center® 800.626.2000  
The GE Answer Center® is open 24 hours a day, 7 days a week.  
SafeyIructions  
In-Home Repair Service 800-GE-CARES (800-432-2737)  
Expert GE repair service is only a phone call away.  
Special Needs Service 800.626.2000  
800-TDD-GEAC (800-833-4322)  
GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons  
with limited mobility.  
OpeagIructions  
Service Contracts 800-626-2224  
Purchase a GE service contract while your warranty is still in effect and you’ll receive a  
substantial discount. GE Consumer Service will still be there after your warranty expires.  
Parts and Accessories 800-626-2002  
Individuals qualified to service their own appliances can have parts or accessories sent directly  
to their homes (VISA, MasterCard and Discover cards are accepted).  
laIructions  
Instructions contained in this manual cover procedures to be performed by any user. Other servicing  
generally should be referred to qualified service personnel. Caution must be exercised, since  
improper servicing may cause unsafe operation.  
ips  
Service Satisfaction  
If you are not satisfied with the service you receive from GE:  
First, contact the people who serviced your appliance.  
Next, if you are still not pleased, write all the details—including your phone number—to:  
rubleshotingT  
T
Manager, Customer Relations  
GE Appliances  
Appliance Park  
Louisville, KY 40225  
CustomSrvice  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Edimax Technology Switch ES 516G+ User Manual
Eiki Cassette Player 5090A User Manual
Eiki Projector LC 7000UE User Manual
Estate Range TGP300T User Manual
FieldServer Computer Drive FS 8700 105 User Manual
Fisher Price Baby Accessories H9998 User Manual
Frigidaire Freezer FPUH19D7L F User Manual
Frymaster Fryer 819 5432 User Manual
Fujitsu Laptop S6220 User Manual
Fusion Car Speaker re sw120 User Manual