Preface  
Content of This Manual  
This manual describes the features and operation of the following industrial computer  
products:  
Model  
Features  
Model  
Features  
IC5002  
IC5005  
IC5008  
12.1" Flat panel display  
BC5002  
12.1" Flat panel display  
with bundled software  
15" Flat panel display  
18" Flat panel display  
BC5005  
BC5008  
15" Flat panel display  
with bundled software  
18" Flat panel display  
with bundled software  
Related Publications  
GFK-1868  
GFK-1180  
CIMPLICITY Machine Edition Getting Started Manual  
CIMPLICITY HMI Plant Edition Base System User's Manual (2 vols)  
GFK-2023C  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Chapter 1  
Product Features .................................................................................................1-1  
Key Features.....................................................................................................1-1  
Bundled Solutions..............................................................................................1-2  
CIMPLICITY Machine Edition (ME) Bundle..................................................1-2  
HMI/SCADA Bundles...................................................................................1-2  
Technical Support..............................................................................................1-4  
Standard Features.............................................................................................1-4  
Contents of the Intelligence Panel PC Package.................................................1-5  
Chapter 2  
Chapter 3  
Safety Instructions...............................................................................................2-1  
Installation Site..................................................................................................2-1  
Damage Resulting from Inappropriate Use........................................................2-2  
Warranty and Repairs........................................................................................2-2  
Transportation Damage.....................................................................................2-2  
Installation ...........................................................................................................3-1  
Installation Procedures ......................................................................................3-2  
Hazardous Locations Installation.......................................................................3-6  
Power Cable Installation Instructions ...........................................................3-6  
Nonincendive Field Wiring Control Drawing CD-E219479  
for USB Port Connections..................................................................................3-7  
Chapter 4  
Chapter 5  
Installing Plug-in Modules..................................................................................4-1  
Avoiding Electrostatic Discharges......................................................................4-1  
Installing Additional Modules .............................................................................4-1  
Installing Expansion Cards ................................................................................4-2  
Configuring Expansion Cards (Legacy ISA Only)...............................................4-3  
Reserving IRQs for ISA Cards in the BIOS ..................................................4-3  
System Operation ................................................................................................5-1  
Initial Startup Procedure ....................................................................................5-1  
System Startup for Windows NT Units...............................................................5-2  
System Startup for Windows 2000 Units............................................................5-3  
Login Recommendation.....................................................................................5-4  
Installing Application Software...........................................................................5-4  
Touchscreen Calibration....................................................................................5-4  
Shutting Down the Computer.............................................................................5-4  
Image Recovery ................................................................................................5-5  
Chapter 6  
Controls ................................................................................................................6-1  
Control Keys......................................................................................................6-1  
Softkeyboard .....................................................................................................6-2  
GFK-2023C  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
External Keyboard.............................................................................................6-2  
Front Panel LEDs ..............................................................................................6-3  
CIMPLICITY ME Template for Hardware Monitoring..........................................6-3  
TouchScreen.....................................................................................................6-3  
Mouse ...............................................................................................................6-4  
Hard Disk...........................................................................................................6-4  
Floppy Disk Drive ..............................................................................................6-4  
CD-ROM Drive ..................................................................................................6-4  
Ports..................................................................................................................6-5  
Networking ........................................................................................................6-6  
Connecting an External Monitor.........................................................................6-7  
Power Supply ....................................................................................................6-7  
Chapter 7  
Driver Installation ...............................................................................................7-1  
Network Adapter Driver Installation....................................................................7-1  
Graphics Driver Installation................................................................................7-2  
TouchScreen Driver Installation.........................................................................7-3  
UDMA Driver Installation ...................................................................................7-4  
Softkeyboard Driver Installation.........................................................................7-4  
Read/Write CD-ROM Utilities.............................................................................7-5  
Chapter 8  
Technical Data .....................................................................................................8-1  
Monitor System..................................................................................................8-1  
Industrial PC......................................................................................................8-1  
Expansion Cards ...............................................................................................8-2  
Dimensions........................................................................................................8-2  
Environmental Specifications.............................................................................8-2  
Standards..........................................................................................................8-2  
Port Configurations............................................................................................8-3  
Pin Assignments................................................................................................8-3  
BIOS Settings....................................................................................................8-5  
Unit Troubleshooting..........................................................................................8-5  
Touchscreen Troubleshooting ...........................................................................8-5  
vi  
Intelligence Panel PC User's Manual–August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Figure 3-1. IC5002/BC5000 Installation Diagram ........................................................................3-3  
Figure 3-2. IC5005/BC5005 Installation Diagram ........................................................................3-4  
Figure 3-3. IC5008/BC5008 Installation Diagram ........................................................................3-5  
Figure 3-4. Cable Clamp Mounting for Power Cable ...................................................................3-6  
Figure 6-1. Front USB Port, All Units...........................................................................................6-5  
Figure 6-2. Expansion and Communications Ports, 12.1" Intelligence Panel...............................6-5  
Figure 6-3. Expansion and Communications Ports, 15" and 18" Intelligence Panels...................6-6  
GFK-2023C  
Contents  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Table 3-1. Critical Dimensions for Installation .............................................................................3-2  
Table 4-1. Intelligence Panel I/O Port Range Table ....................................................................4-4  
viii  
Intelligence Panel PC User's Manual–August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Features  
Chapter  
1
The Intelligence Panel industrial PC is designed to meet the demands of advanced control  
and monitoring architectures. All GE Fanuc industrial computers meet industrial  
requirements for factory automation applications, including extended temperature, shock  
and vibration, and NEMA 4 sealed front panels. Coupling the industrial packaging with the  
latest in processor technology and state-of-the-art flat-panel displays, this industrial PC  
delivers outstanding performance to the factory floor.  
Available in 12", 15" or 18" flat panel displays with active matrix Thin Film Transistor (TFT)  
technology, the Intelligence Panel PC provides installation flexibility and wide viewing  
angles for the most demanding industrial applications. Intelligence Panel PC is available  
as a stand-alone product, or bundled with HMI/Control or HMI/SCADA software offerings.  
Key Features  
Standard model: 1.0 GHz CPU, or greater, 256 MB RAM with CD ROM (read only)  
Performance model: 1.4 GHz CPU, or greater, 256 MB RAM with Read/Write CD  
ROM  
40 GB hard drive  
12”, 15” or 18” active matrix TFT Touch Screen displays  
Two independent 10/100 base-T Ethernet ports  
Two or three ISA/PCI expansion slots (open) – Standard and Performance models  
PS/2 mouse, PS/2 keyboard, USB ports, three serial ports, one parallel port  
Five system-level software integration keys (Soft keyboard, Right mouse click,  
brightness control. etc.)  
System hardware monitoring (temperature, fan)  
CE marked; UL 1604 Certification; NEMA 4  
Operating System (OS) Recovery disk  
GFK-2023C  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1
Bundled Solutions  
The Intelligence Panel PC is available as a bundled system with the HMI or Control  
application software of your choice, such as CIMPLICITY® HMI, Intellution iFIX, or  
CIMPLICITY Machine Edition, launched from Windows NT® or Windows® 2000 operating  
systems. Whatever your choices, powerful processors with PCI and ISA backplanes are  
standard in every Intelligence Panel PC. To save you time and money, GE Fanuc  
integrates and tests the powerful hardware and software combination on the Intelligence  
Panel PC at our factory.  
The Intelligence Panel PC fits seamlessly into your control application and accommodates  
your ever-changing industrial requirements. End users, OEM, and system integrators will  
see a single integrated hardware and software platform that provides a scalable  
computing platform from the factory floor devices to the business enterprise at a lower  
cost.  
CIMPLICITY Machine Edition (ME) Bundle  
The Intelligence Panel PC bundled with Machine Edition software offers a true out-of-the-  
box Web-enabled solution for machine and process level HMI and PC-based control  
applications. Incorporating a single user interface, Machine Edition hosts several  
development and runtime engines within a common environment. Operator interface and  
PC-based motion control programming are just a few of the included components.  
Machine Edition comes with run-time and development software. There are two options  
available:  
CIMPLICITY Machine Edition View Run-time & Development (also known as View  
Station )  
CIMPLICITY Machine Edition Control & View Run-time Only, as well as Run-time &  
Development (also known as Control Station )  
HMI/SCADA Bundles  
GE Fanuc’s Intelligence solutions are the ideal platform for visualization, automation and  
control. iFIX and CIMPLICITY HMI software products combine our rugged hardware units  
with our powerful software applications and are designed to uniquely suit your needs for  
process or discrete environments.  
iFIX, with an information rich automation oriented Function Block Database combined with  
a robust and extensible graphics environment, is an ideal option for meeting all your  
supervisory control and data acquisition needs.  
iFIX functionality includes features created specifically to address the electronic signature  
and advanced audit trail needs of regulated industries. This added functionality empowers  
you to introduce new levels of security and accountability into any application in your  
organization, regardless of industry. Some markets ideally suited to iFIX include  
water/wastewater, food and beverage, pharmaceutical, metals, oil and gas, mining and  
others with a process orientation.  
CIMPLICITY HMI provides advanced functionality that establishes a solid foundation for a  
robust, powerful HMI interface and is the best option for applications with a greater  
1-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1
discrete manufacturing orientation. A true client/server architecture and open-system  
design offers fast, easy integration. CIMPLICITY HMI gives you the ability to grow from a  
single computer node to a plant-wide monitoring and control system providing real-time  
information from the factory floor to all levels of the enterprise.  
CIMPLICITY HMI offers powerful operator interface and machine control functionality.  
Several markets and applications that are ideally suited to CIMPLICITY HMI include  
automotive, aerospace, plant floor, HMIs, discrete manufacturing, machining,  
semiconductor, CNC, Motion Control, and Consumer Packaged Goods among others.  
Both products use the latest web technologies to provide you with visibility into the key  
metrics you need to run your manufacturing operations efficiently and effectively. This  
data can made available to one of the many web-enabled display devices on the market  
today. Whether it is a standard web browser, hand-held PDA, wireless bar code reader or  
industrial hardened CE device, you get real-time access to the important information  
needed to operate your business.  
GFK-2023C  
Chapter 1 Product Features  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Technical Support  
GE Fanuc provides a single resource for all your services and support needs including  
technical software support, product training, and complete application consultation and  
development services.  
Phone: 1-800-433-2682 (1-800-GEFANUC)  
Standard Features  
IC5002  
IC5005  
IC5008  
TFT LC-Color Touch Display  
383.5 mm (15.1")  
Display  
307.4 mm (12.1")  
459.7 mm (18.1")  
Diagonal  
SVGA (800 x 600)  
XGA (1024 x 768)  
SXGA (1280 x 1024)  
Resolution (Pixel)  
VGA controller  
(AGP 1x)  
2MB SDRAM  
(AGP 1x)  
2MB SDRAM  
(AGP 1x)  
4MB SDRAM  
256k  
64k  
64k  
Colors  
300 cd/m²  
400 cd/m²  
250 cd/m²  
Brightness  
Touch Screen  
Analog. 5 wire resistive with serial interface internal connected to COM4  
1. Soft key board via Touch Screen  
2. Task changes (Alt + Esc)  
3. Hot-Key  
Front key  
functions  
4. Right mouse button  
5. Display adjustment brightness  
All in Passive PCI/ISA bus slot CPU with FCPGA-Socket for Intel processor  
1.0 GHz (Optional: PIII 1.4 GHz. FSB 133)  
Slot-CPU  
Processor  
RAM  
256 MB SDRAM (1 DIMM Slot)  
Hard disk min. 40 GB minimum (3.5" UDMA)  
3.5" Floppy disk  
Storage  
5.25" CD-ROM (Optional: CD-RW)  
COM1/2/3 (RS232)  
LPT1  
Ports  
Keyboard PS/2  
Mouse PS/2  
CRT Monitor  
Two USB (one front, one side)  
Two 10/100BaseT (RJ45, 10/100Mbit full duplex)  
Network  
Slots  
Two shared ISA/PCI  
Two shared ISA/PCI  
One PCI  
Two shared ISA/PCI  
One PCI  
100—240 VAC, 50—60Hz, 100 watt  
Power supply  
48 watt (typical)  
60 watt max.  
54 watt (typical)  
62 watt max.  
67 watt (typical)  
75 watt max.  
Power  
consumption  
NEMA4/12; Front IP65  
Protection  
1-4  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1
Contents of the Intelligence Panel PC Package  
Check that one of each of the following items is included in the package with your  
Intelligence Panel PC:  
Industrial flat panel PC  
Conventional power cable and plug  
Hazardous Environment power cable and plug mounting kit  
User manual  
Axiom CD: SBC Drivers, Utilities & User Manuals  
ELO TouchSystems CD  
Soft Keyboard Floppy Disk  
Device panel mounting kit  
NERO CD: CD read/write driver  
Media Kit for License Software  
Operating System Recovery floppy disk  
GFK-2023C  
Chapter 1 Product Features  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Safety Instructions  
Chapter  
2
Warning  
This equipment carries electric currents and contains highly-  
sensitive components. Other than plugging in additional cards or  
modules, you should not attempt modifications to the unit. If other  
modifications need to be made, the manufacturer or an authorized  
service agent must be contacted. The unit must be switched off at  
the main power supply and the power cable disconnected during  
such work. Suitable precautions must be taken to avoid electrostatic  
discharge on contact with components. If an unauthorized person  
opens the product case, danger to the user may arise and the  
warranty will be void.  
Caution  
To prevent damage to the unit, do not attempt to connect leads  
(power supply and port cables) unless the unit is switched off.  
Installation Site  
The Intelligence Panel is designed for installation in a metal cabinet. The ambient conditions  
specified in chapter 8, “Technical Data” must be maintained. Installation in an environment  
not specified in Technical Data, for example exposed to extended temperatures or at  
extreme altitudes, may void the warranty.  
Warning  
When installing the unit in an environment where there is the  
potential for flammable gases, vapors or liquids to be present, the  
power cable must be secured to the unit using the enclosed cable  
clamp kit. In addition, the power cable must have the male plug  
removed and be permanently hard-wired to the AC source. For  
details, refer to “Hazardous Locations Installation” in chapter 3.  
GFK-2023C  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Damage Resulting from Inappropriate Use  
If the Intelligence Panel displays signs of damage caused by inappropriate  
operating/storage conditions, mounting, or incorrect handling, the unit must be taken out of  
use immediately and secured against unintentional operation.  
Warranty and Repairs  
Repairs under warranty may only be made by the manufacturer or by agents authorized by  
the manufacturer.  
For return authorization, contact 1-800-432-7521 Customer Service. Be prepared to provide  
delivery date, product model, customer order number, unit serial number, and reason for  
return request.  
Caution  
Units must be returned to the factory in the original shipping  
container. If you do not have the original shipping container, contact  
GE Fanuc Customer Care to order a new shipping container. . The  
part numbers are 44B714940-001R01 (Carton) and 44B714939-  
001R01 (Insert). For proper shipping one carton and two inserts are  
required. If the units are not returned in the original shipping  
container the warranty is voided.  
Transportation Damage  
Warning  
If the product has incurred obvious damage during transportation,  
do not apply power  
If the product has incurred obvious damage during transportation, you should avoid applying  
power. Obvious transport damage should be reported to the supplier immediately. Less  
obvious damage that becomes evident in the early operation of the product must be  
reported within five days of the initial delivery for consideration as transportation damage.  
2-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Chapter  
3
Intelligence Panel PCs are designed for installation in switchboard panels and cabinet  
doors. To facilitate installation and access to connectors, switchboard panels and  
consoles must be accessible from the rear. The unit can be installed in switchgear  
cubicles or cabinets with wall thicknesses of 2mm to 13mm (0.079 – 0.5 inches). For  
optimum sealing with the cabinet face, the recommended wall thickness is  
3mm (0.118 inches).  
Air Inlets and outlets must have at least 25mm (approx. 1.0 inch) of space around them  
and not be obstructed. Adequate airflow around the exterior of the unit is important to the  
interior temperature of the unit. Two fans are used to create air flow through the industrial  
computer to maintain a correct working temperature.  
Caution  
Only correct mounting ensures front-side NEMA and IP65 protection  
Caution  
The IC5005/BC5005 and IC5008/BC5008 units must be installed and  
operated in a vertical position to ensure the correct operating  
position of the CD-ROM drive.  
Caution  
Viewed from the front, there must be sufficient space (132 mm or  
5.20 in. minimum) to the left of the units to allow the CD-ROM drive  
drawer to open.  
GFK-2023C  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3
Installation Procedures  
1. Make a cut-out (corresponding to size of the particular unit) in the switchgear panels  
or cabinet doors (see Figures 3-1 through 3-3).  
2. Insert the unit into this cut-out from the front.  
3. Insert the mounting screws together with mounting blocks in the slots provided in the  
metal cover and tighten all screws evenly until the surround panel covers the cut-out  
securely. Maximum torque is 0.25 N-m (2.2 lbf-in).  
Caution  
Over tightening the screws will cause irreparable damage to the  
front panel and break the touch screen itself.  
Connect the provided power cord to the AC power supply. If additional grounding to a  
grounding screw is desired, use 14 AWG gauge wire minimum.  
Table 3-1. Critical Dimensions for Installation  
Dimension  
IC5002  
IC5005  
IC5008  
BC5002  
BC5005  
BC5008  
Cover (W x H)  
313 x 252mm  
23.3 x 9.9 in.  
373.6 x 295.6 mm  
14.7 x 11.6 in.  
426 x 355mm  
16.8 x 14.0 in.  
Cutout (recess) (W x  
H)  
318 x 256mm +1.0mm 376 x 299mm +1.0mm 428 x 358mm +1.0mm  
12.5 x 10.1 in. + 0.04  
in.  
14.8 x 11.8 in. + 0.04  
in.  
16.9 x 14.0 in. + 0.04  
in.  
Space required for  
ventilation  
Minimum 50mm (2 in) clearance at top and bottom of the unit. Minimum  
30mm (1.2 in.) at sides.  
Note additional side space consideration is required for models with CD-  
ROM, depending on cabinet design. Viewed from the front, there must be  
sufficient space (132 mm or 5.20 in. minimum) to the left of the units to  
allow the CD-ROM drive drawer to open.  
Mounting depth  
177mm  
6.97 in.  
150mm  
5.9 in.  
154mm  
6.1 in.  
3-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3
0
70  
260  
330  
0
6x Mounting blocks M4  
View from back side  
Dimensions:  
Cover:  
Mounting depth:  
Space required for cooling:  
313 x 252 mm (W x H)  
83 mm  
Approximately 50 mm around the unit  
134  
158  
318 x 256 mm +1,0 (W x H)  
Recess:  
132 mm  
CD Drawer  
Clearance  
Outer edge of cover  
268  
Outer edge of recess  
Outer edge of frontpanel  
Figure 3-1. IC5002/BC5000 Installation Diagram  
GFK-2023C  
Chapter 3 Installation  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
0
31  
186  
341  
390  
0
8x Mounting blocks M4  
View from back side  
125  
156  
Dimensions:  
Cover:  
Mounting depth:  
Space required for ventilation:  
373,6 x 295,6 mm (W x H)  
150 mm  
Approximately 50 mm around the unit  
Recess:  
376 x 299 mm +1,0 (W x H)  
132 mm  
CD Drawer  
Clearance  
Outer edge of cover  
312  
Outer edge of recess  
Outer edge of frontpanel  
Figure 3-2. IC5005/BC5005 Installation Diagram  
3-4  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
0
40  
221  
402  
442  
0
8x Mounting blocks M4  
View from back side  
Dimensions:  
Cover:  
Mounting depth:  
426 x 355 mm (W x H)  
154 mm  
Approximately 50 mm around the unit  
Space required for ventilation:  
185,5  
199,5  
Recess:  
428 x 358 mm +1,0 (W x H)  
132 mm  
CD Drawer  
Clearance  
Outer edge of cover  
371  
Outer edge of recess  
Outer edge of frontpanel  
Figure 3-3. IC5008/BC5008 Installation Diagram  
GFK-2023C  
Chapter 3 Installation  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Hazardous Locations Installation  
Warning  
When installing the unit in an environment where there is the  
potential for flammable gases, vapors or liquids to be present the  
power cable must be secured to the unit using the enclosed cable  
clamp kit. In addition, the power cable must have the male plug  
removed and be permanently hard-wired to the AC source.  
Mounting holes for  
cable clamp  
Power connector  
Figure 3-4. Cable Clamp Mounting for Power Cable  
Power Cable Installation Instructions  
1. Attach clamp to power plug with the two screws provided.  
2. Plug power cable into power connector on unit.  
3. Securely attach the power plug and clamp assembly to the chassis at the two screw  
holes provided to the left and right of the plug.  
3-6  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3
Nonincendive Field Wiring Control Drawing CD-E219479  
for USB Port Connections  
Hazardous (Classified) Location  
Class I, Division 2 Groups A, B, C, and D  
Front USB Port on Computer No._________________  
Associated Nonincendive  
Field Wiring Apparatus  
(Computer)  
Nonincendive Field  
Wiring Apparatus  
Vmax  
Imax  
Ci  
Voc  
Isc  
Ca  
La  
Li  
Notes:  
1. Nonincendive Circuit Parameters:  
Voc = 4.969 VDC  
Isc = 2.06 A  
Ca = 75 µF  
La = 40 µH  
2. Selected Nonincendive Field Wiring Apparatus shall satisfy the following:  
Voc  
Isc  
Ca  
La  
Vmax  
Imax  
Ci + C cable  
Li + L cable  
3. If the electrical parameters of the cable are unknown, the following values may be  
used:  
Capacitance – 60 pF/ft  
Inductive – 0.20 µH/ft  
4. Nonincendive Field Wiring must be installed in accordance with Article 501.4(B)(3) of  
the National Electrical Code ANSI/NFPA 70.  
5. Selected Nonincendive Field Wiring Apparatus must not be connected to external  
power source.  
GFK-2023C  
Chapter 3 Installation  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing Plug-in Modules  
Chapter  
4
PCI bus or ISA bus plug-in modules, such as network or field bus cards, can be installed  
in the Intelligence Panel. The plug-in slots are accessed by removing the rear cover,  
which is secured by cross-head screws.  
Avoiding Electrostatic Discharges  
Caution  
The components in Intelligence Panel PCs are susceptible to  
electrostatic discharge (ESD) and can be functionally damaged by  
incorrect handling. The same applies to plug-in modules. It is  
therefore vital that suitable precautionary measures are taken to  
avoid electrostatic discharges on contact with the components.  
1. Before touching components or modules, always touch a metal object with a  
conductive surface that is connected to ground potential.  
2. Wear a wrist strap.  
3. When handling modules, only touch the edges or the module bracket, not the  
components themselves.  
Installing Additional Modules  
Caution  
To avoid a risk of electric shock, turn off power to the industrial  
computer and disconnect the power supply before removing the rear  
panel.  
1. Switch off the Intelligence Panel and all units connected to the PC and disconnect the  
PC from the power source.  
2. Remove the screws from the rear panel and pick up the cover carefully.  
GFK-2023C  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
Caution  
The rear cover is connected to the base units of the Intelligence  
Panel by a plug-in ground connector and cable. Carefully remove  
and orient the rear cover to avoid applying unnecessary tension on  
this cable.  
3. Select a free slot and remove the blank cover plate from this slot.  
4. Using the precautionary measures described in “Avoiding Electrostatic Discharges,”  
remove the plug-in module from its packaging, plug it into the slot and screw it  
securely to the bracket.  
5. When the module has been installed, refit the ground connector (if disconnected) and  
replace the rear panel, ensuring that the side clips are correctly positioned.  
6. Tighten the six screws on the rear panel.  
Installing Expansion Cards  
All the expansion slots in the system allow the card to be clamped into place using  
standard PC card clamping.  
Wear a properly functioning antistatic strap and be sure that you are fully  
grounded. Never touch the card, or any components inside the computer  
unless you are wearing an antistatic strap.  
Any surface upon which you place the unprotected card should be static-safe,  
facilitated by antistatic mats if possible.  
Extra caution should be taken in cold, dry weather, when static charges can  
easily build up.  
Slot Cover Plates  
Cover plates are fitted to each unused card position. These plates can be removed as  
necessary to install new cards. Any empty slots must have a cover plate fitted, otherwise  
agency approvals become invalid.  
4-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
Configuring Expansion Cards (Legacy ISA Only)  
Caution  
For most applications, an interrupt request (IRQ) or address cannot  
be shared by more than one resource. If more than one resource is  
set to the same IRQ or address, the application may not respond  
properly and could cause your machine to lock up. Following these  
instructions when installing Legacy ISA cards will prevent problems  
with resource conflicts.  
The controllers (Ethernet, IDE) in the slot CPU of the IPC are connected via an internal  
PCI bus. This ensures that addresses and IRQs are automatically determined by the  
BIOS. When making changes to the configuration or adding ISA cards:  
1. Install the unit without ISA cards, switch on and read off assigned IRQs and  
addresses.  
2. Install additional ISA cards so that IRQs assigned to PCI are not reused (interrupt  
sharing).  
3. Reserve IRQs for ISA in the BIOS  
Reserving IRQs for ISA Cards in the BIOS  
Legacy ISA cards are the oldest standard and require memory, I/O, and IRQ settings to  
be manually set on the card using jumpers, DIP switches, or a configuration program. The  
card and system need to have the same hardware settings.  
The GE Fanuc web site http://gefanuc.com/ provides current information on BIOS settings  
for IRQs.  
1. Connect a keyboard, turn on the system power, and press F2 when prompted to enter  
the BIOS Setup program.  
2. Select Advanced, then PCI Configuration, and PCS ISA Resource Exclusion.  
3. If the card requires one or more interrupts, go to an IRQ that currently reads  
"Available" and change it to "Reserved" by pressing +/-. Do not use an IRQ that  
already reads "Reserved."  
4. If the card requires memory space, press the arrow key to return to the PCI  
Configuration screen. Select PCI ISA UMB Region Exclusion. Go to a memory block  
that currently reads "Available" and change it to "Reserved" by pressing +/-. Do not  
use a memory block that already reads "Reserved."  
5. Press ESC to exit the configuration screen. In the Exit menu, select Exit Saving  
Changes and to save and exit Setup. When the screen goes blank, turn off the power.  
6. If the card has jumpers or DIP switches, set them so that they match the IRQ and  
memory addresses set in the BIOS Setup.  
7. Set the I/O port settings of the card (if any) so that they fall within the ranges labeled  
"Available" in the following table.  
GFK-2023C  
Chapter 4 Installing Plug-in Modules  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
8. If the card is set up using a configuration program, proceed with installation, run the  
card’s configuration program. Set the IRQ and memory address to the same settings  
as those put into BIOS Setup. Set the I/O port settings (if any) to a range labeled  
“Available” in the following table.  
Table 4-1. Intelligence Panel I/O Port Range Table  
000-1FF  
200-277  
278-2FF  
300-377  
378-3DF  
3E0-3EF  
3F0-3FF  
Reserved  
Available  
Reserved  
Available  
Reserved  
Reserved  
Reserved  
4-4  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
System Operation  
Chapter  
5
This chapter covers the following topics:  
Initial startup procedure  
System startup for Windows NT  
System startup for Windows 2000  
Login  
Installing Application Software  
Image Recovery  
Shutting Down the Computer  
Initial Startup Procedure  
Warning  
Installation of the Intelligence Panel in hazardous locations requires  
the use of a cable mounting clamp with the power connector. For  
instructions for installing this clamp, refer to “Hazardous Locations  
Installation” in Chapter 3.  
1. Plug the power cable into the unit’s power connector and connect to the power  
source.  
2. Plug in the serial/parallel data transfer cables and screw the plugs to the connectors.  
Caution  
To prevent damage, do not attempt to connect leads unless the unit  
is switched off.  
Note: The data cable shield must be connected to the housing of the  
push-on connector (EMC).  
3. Switch on the unit and check whether any concealed damage has been caused by  
incorrect transportation, incorrect operating/storage conditions or incorrect handling  
(e.g. smoke coming out of the unit, etc.). If you notice any damage, switch off the unit  
immediately and secure it against unintentional use.  
GFK-2023C  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
System Startup for Windows NT Units  
Connecting a PS/2 keyboard and mouse is recommended before you get started. You  
need a PS/2 keyboard for convenience. An alternate approach is to use the soft keyboard  
and touch panel.  
1. Plug in the keyboard, PS/2 mouse (if available), and power cord.  
2. Power on the unit.  
3. Read the license agreement  
4. TAB to your choice and press ENTER.  
5. Press ENTER to start the Windows NT Setup.  
6. Type your name.  
7. Press the TAB key and type your company name.  
8. Press ENTER.  
9. Enter the Windows NT Authentication number found on your Windows NT manual.  
You will need to use the TAB key to get to each number field. If correct, press ENTER.  
Note: Computer names must be less than or equal to ten characters to  
run CIMPLICITY HMI software. Each computer on a network  
must have a unique name.  
10. Enter a Computer name. This name must be different from other computer names on  
the same network. Press ENTER.  
Note: Your system has been set up to enable auto logon. Auto logon  
allows the system to boot into Windows NT without your having to  
use a keyboard to press CTRL-ALT-DEL.  
11. You will be prompted for a password.  
To use the auto logon feature, type admin for the password. Press the TAB key  
and type admin in the Confirm Password box. Press ENTER.  
To skip the password, press ENTER  
To assign a password, type in a password, press the TAB key, and type the  
password in the Confirm Password box. Press ENTER.  
12. Press ENTER to continue with Windows NT Setup.  
Note: The factory setting for the IP is 111.111.111.111 and for the  
Subnet is 255.0.0.0. If necessary, consult your network  
administrator to select appropriate addresses.  
13. After completing the network setup, the system will copy files over and finalize its  
setup.  
14. At the end of the setup process, you will be asked to reboot the system. Press ENTER.  
5-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
System Startup for Windows 2000 Units  
Connecting a PS/2 keyboard and Mouse is recommended before you get started. You  
need a PS/2 keyboard for convenience. The soft keyboard and touch panel will not work  
until the Windows 2000 operating system is licensed. Therefore an external keyboard is  
required to license the product.  
1. Plug in the keyboard, PS/2 mouse (if available), and power cord.  
2. Power on the unit.  
3. Read the license agreement.  
4. Select your choice and press NEXT >.  
5. Choose your regional settings (US default) and press NEXT >.  
6. Type your name.  
7. Press the TAB key and type your company name.  
8. Press NEXT >.  
9. Enter your Windows 2000 Product Key found on the back of the Intelligence Panel.  
When correct, press NEXT >.  
Note: Computer names must be less than or equal to ten characters to run CIMPLICITY  
HMI software. Each computer on a network must have a unique name.  
10. Enter a Computer name. This name must be different from other computer names on  
the same network. Press Next >.  
11. If desired, enter an Administrator password. You will need to enter it twice to confirm.  
When done, press Next >.  
12. You can now set the Date, Time and Time Zone for the computer. When the  
information is correct, press Next >.  
13. Choose Typical settings for the factory setting of TCP/IP protocol at IP  
111.111.111.111 and subnet 255.0.0.0, or, choose Custom and press Next > to  
change these settings. Consult your network Administrator for your network’s  
configuration settings.  
14. Choose whether this computer will be on a workgroup or domain and enter the name  
and press Next >.  
15. After completing the network setup, the system will finalize its setup.  
At the end of the setup process, you will be asked to reboot the system. Press Finish.  
After restarting, you will need to configure the login settings for Windows 2000. When the  
“Network Identification Wizard” dialog box appears press Next >.  
The “Users of This Computer” dialog box appears.  
If you wish to have the computer automatically log on with the administrator  
account, select the “User name” pull down and choose “Administrator.” Enter the  
password used in step 11 and press NEXT >. The computer will automatically log  
on when it starts up.  
If you wish to require a logon when the computer is restarted, select “Users must  
enter a user name and password to use this computer” and press NEXT >. You will  
then be asked for a user name and password when the computer starts up.  
16. Press Finish and the setup is complete.  
GFK-2023C  
Chapter 5 System Operation  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
Login Recommendation  
With Windows NT, if you type admin as your Administrator password, your industrial  
computer will automatically log on as Administrator.  
Log onto the system as Administrator when you power up the system. Doing so eliminates  
the requirement to log on to CIMPLICITY when you run the CIMPLICITY Demo or any  
other CIMPLICITY project that includes a user named Administrator. All CIMPLICITY  
projects are configured with an Administrator user by default.  
Installing Application Software  
The Windows operating system and GE Fanuc software (except IC850PCT400) are  
loaded onto the industrial computer at manufacture. If it is necessary to reload software,  
follow the instructions in the documentation supplied with the software.  
Touchscreen Calibration  
1. Open Control Panel, by selecting Start, Settings, then Control Panel.  
2. Select the Elo Touchscreen icon in the Control Panel window.  
3. Select Calibrate in the Elo Touchscreen properties window.  
4. Follow the on-screen instructions to calibrate the Touchscreen.  
Shutting Down the Computer  
Caution  
To avoid damaging files, always shut down Windows Operating  
System before removing power from your Intelligence Panel.  
To shut down Windows Operating System, select the Start menu and  
choose Shut Down.  
5-4  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
Image Recovery  
The IPC features a hidden partition on the hard drive that contains an OS recovery image.  
This image can be used to recover a corrupt OS.  
Instructions for OS recovery:  
Warning  
Before attempting an Image Recovery on your unit, make sure to  
record all critical settings and conduct a full back up of all software  
projects and critical documents. You will also need to have your  
software (CIMPLICITY software product) registration and Microsoft  
Authorization Numbers handy. This process will clear all contents  
from your Hard Drive and return your system to the factory  
configuration.  
1. Prior to Image Recovery, a standard PS/2-type keyboard should be connected to the  
external keyboard port.  
1. Set CMOS settings to allow the unit to start up from the floppy drive (A:)  
2. Install the supplied OS Recovery Disk.  
3. Start the system. Recovery begins automatically.  
4. When recovery is complete, remove the floppy disk and restart the system.  
5. Relicense the OS using the license label supplied.  
On Windows 2000 units, the license is on the back of the unit.  
On Windows NT units, the license is provided on the supplied OS packet.  
MS-DOS is a registered trademark of Microsoft Corporation.  
GFK-2023C  
Chapter 5 System Operation  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Controls  
Chapter  
6
Control Keys  
Intelligence Panel PCs are shipped with the Windows NT or Windows 2000 operating  
system installed. Additional pre-installed software includes drivers to support the virtual  
keyboard. In case you need to re-install the software, CDs and floppy disks are included  
with the appropriate drivers.  
The five keys on the front panel are assigned the following default functions.  
Opens and closes the virtual keyboard to allow character input via the  
TouchScreen  
With SHIFT key: No function.  
Switches tasks (ALT+ESC) in Windows.  
With SHIFT key: No function.  
Hot Keys: Launches application - Starts the text editor (Notepad) as the default.  
With SHIFT key: Increases display brightness.  
Right mouse key function.  
With SHIFT key: Decreases display brightness.  
SHIFT key for upper case. The SHIFT key must be pressed at the same time as  
the desired function key.  
The general system keys can be disabled or configured to launch an application or tool  
through an .ini file. For information on application instructions, see the GE Fanuc web site  
Note: If the Softkeyboard is not installed, only the display setting functions are active.  
Note: You can alter the default settings of the virtual keyboard. Information on altering  
the settings can be found in the README file on the floppy disk.  
GFK-2023C  
6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Softkeyboard  
A virtual keyboard that allows you to enter data using the TouchScreen in a similar way to  
a normal keyboard is supplied with the Intelligence Panel. If the Intelligence Panel is  
delivered without an installed operating system, you can install the Softkeyboard using the  
floppy disk provided (see chapter 7, “Driver Installation”). This also automatically installs  
the keyboard assignment for the five keys below the display at the front.  
Note: To access commands that require two keys to be pressed simultaneously on a  
standard keyboard (e.g. ALT + F4), these keys have to be pressed one after the  
other on the virtual keyboard. The special SHIFT, ALT and CTRL keys always have  
to be pressed first.  
Note: Because of programming differences in different software packages, it cannot be  
guaranteed that the virtual keyboard will be compatible with all software.  
Softkeyboard Controls  
Increases the size of the Softkeyboard display  
Decreases the size of the Softkeyboard display  
Free area Moves the virtual keyboard on the screen  
External Keyboard  
A 6-pin mini-DIN Keyboard socket (PS/2) is located on the side of the operating console.  
Industry-standard, AT-compatible quality keyboards with the appropriate connector can be  
plugged into this socket. The suitability of keyboards must be checked before installation.  
Note: When the virtual keyboard is displayed as active on screen, only  
a limited range of controls are available on the external keyboard.  
6-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Front Panel LEDs  
PWR LED  
When the SHIFT key is used to adjust the display settings, the LED goes out. If one of the  
other four keys is also pressed, the LED flashes until the limit of the adjustment range is  
reached.  
The following modes are also displayed:  
Green light:  
Red light:  
Indicates ready status (Power ON)  
Processor fan speed too slow or stopped  
Unit overheating  
Red flashing:  
Note: The overheating error signal has priority over fan errors and is  
therefore displayed if both errors occur.  
Note: To ensure that the user has noticed the error signal, the red  
Overheating and Fan Speed LED signals can only be reset by  
restarting the computer.  
CIMPLICITY ME Template for Hardware Monitoring  
When using CIMPLICITY Machine Edition or CIMPLICITY HMI, an OPC driver is provided  
to monitor the PC condition through system status variables. The following features can  
be monitored:  
CPU Fan error  
Chassis Fan error  
CPU over temperature (greater than 50 degrees C)  
On board NTC (-127 degree C to +127 degree C)  
TouchScreen  
The operating console is provided with the analog TouchScreen with serial controller,  
which is connected internally to the COM4 serial port. To be able to use the TouchScreen,  
the driver software must be integrated in the relevant operating system (see  
“TouchScreen Driver Installation” in chapter 7).  
GFK-2023C  
Chapter 6 Controls  
6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Mouse  
A Microsoft-compatible mouse with PS/2 connector can be attached to the Mouse port.  
The compatibility of the mouse must be checked before use. The mouse can be used in  
addition to the TouchScreen.  
Note: It is recommended that you connect a PS/2 mouse to the mouse  
port during installation as the TouchScreen is not yet usable. This  
considerably simplifies the process of initial installation of the  
operating system. The mouse can be removed later without an  
error message.  
Hard Disk  
The hard disk is fitted to a mounting plate with vibration-damping rubber elements. A 3.5"  
Ultra-DMA hard disk with commonly available capacity (minimum of 20 GB) is provided.  
Floppy Disk Drive  
The floppy disk drive is fitted on the left of the operating console (viewed from the front)  
next to the Intelligence Panel ports.  
CD-ROM Drive  
The CD-ROM drive is on the left of the operating console (viewed from the front) under  
and next to the Intelligence Panel ports. The CD-ROM drive cannot be opened unless the  
Intelligence Panel is switched on. Pressing the Eject button activates a motor that opens  
the drawer. The drawer can be closed again by pushing the drawer gently or by pressing  
the Eject button.  
Caution  
To avoid damage to the drive, ensure that the motorized drawer is  
not obstructed as it opens. (See “Installation Procedures” in  
chapter 3.)  
6-4  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Ports  
A USB port is provided on the front of the operating console. All other ports are arranged  
in the housing on the left of the operating console (viewed from the front). All ports are  
labeled. For pin assignments, refer to chapter 8, “Technical Data”.  
Caution  
To prevent damage to the unit, do not attempt to connect leads  
unless the unit is switched off.  
Figure 6-1. Front USB Port, All Units  
USB  
COM 1  
COM 3  
Ethernet  
COM 2  
CRT  
LPT 1  
PS/2  
PS/2 Mouse  
Keyboard  
Figure 6-2. Expansion and Communications Ports, 12.1" Intelligence Panel  
GFK-2023C  
Chapter 6 Controls  
6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Ethernet  
COM 1  
USB  
CRT  
COM 3  
Floppy  
Disk Drive  
COM 2  
LPT 1  
PS/2  
Keyboard  
PS/2 Mouse  
CD-ROM  
Drive  
PCI/ISA (2) and  
ISA slots  
Figure 6-3. Expansion and Communications Ports, 15" and 18" Intelligence Panels  
Networking  
The Intelligence Panel can be integrated into an Ethernet supporting 10 or 100 Mbit/sec.  
using an appropriate network cable from the Ethernet network port (10/100Base-T).  
Network architecture specifications must be observed. The CD supplied with the unit  
contains drivers required for network operation, which must be installed according to the  
particular operating system (see Chapter 7, “Driver Installation”).  
6-6  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Connecting an External Monitor  
A CRT-Multisync monitor can be operated from the 15-pin monitor connection in parallel  
with the integral flat screen. The monitor must be capable of running at a minimum  
horizontal frequency between 31-69 kHz, otherwise the maximum resolution of 1280 x  
1024 pixels cannot be displayed.  
Caution  
Do not connect a standard VGA monitor (horizontal frequency 31.5  
kHz) as it will be damaged by timing changeovers!  
Power Supply  
The Intelligence Panel is fitted with an auto-switching power supply.  
Primary voltage 100-240 VAC (50-60 Hz)  
ON/OFF switch  
Power connector with surge protection (to provide protection against power surges  
and spikes)  
GFK-2023C  
Chapter 6 Controls  
6-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Driver Installation  
Chapter  
7
Intelligence Panel PCs are shipped from the factory with the Windows operating system  
pre-installed. Depending on the product purchased, CIMPLICITY software is also  
preinstalled. For configurations where no operating system is installed or the operating  
system needs to be re-installed, you must perform a complete installation procedure and  
set up all necessary drivers. The original CDs and a Softkeyboard floppy disk are supplied  
with the unit.  
Note: During installation it is recommended that you connect a PS/2 mouse to the  
mouse port because the TouchScreen is not yet usable. This simplifies the  
process of initial installation of the operating system. The mouse can be removed  
later without an error message.  
Network Adapter Driver Installation  
Caution  
To install the driver for the network card, the installation files from  
the CD "SBC Drivers, Utilities & User Manuals" (file path:  
CD:\SBC8260\DRIVER\LAN\WINNT) must be copied to the main  
directory of a floppy disk.  
To install the integrated network port for Windows NT:  
1. Plug the network cable (TP) into the IPC and connect to the network.  
2. Switch on the PC and begin installation of Windows NT 4.0.  
3. Confirm the Create Connection Between Computer and Network and Connect Directly  
to the Network messages.  
4. Click the Select From List option and select Floppy disk.  
5. Confirm the displayed path A:\ with OK.  
6. In the next window select the following driver (card) and confirm with OK:  
RTL8139 (A/B/C/8130) PCI Fast Ethernet Adapter.  
GFK-2023C  
7-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7
Caution  
If selecting DHCP, the IPC must be connected to the DHCP-  
supported network.  
7. Click Next to define settings for the network protocol desired by the specific user and  
the operating mode (default setting: (1) Auto). If selecting the TCP/IP protocol, the  
DHCP mode or fixed IP address must also be selected.  
8. Click Next to enter user-specific work groups and domain data.  
9. Continue installing Windows NT.  
Graphics Driver Installation  
Since Windows NT 4.0 installation only installs a standard VGA driver supplied by the  
operating system manufacturer, this needs to be replaced in order to make full use of the  
capabilities of the high-resolution flat screen. The driver can be found on the "SBC  
Drivers, Utilities & User Manuals CD). Installation is performed as follows:  
Caution  
For Windows NT, do not install the driver unless Service Pack 3 or  
higher has been installed since in earlier versions Windows does  
not support the AGP interface of the graphics card. Do not install the  
driver during initial installation of the operating system.  
1. Switch on the PC and after the system has booted up, insert the SBC Drivers CD in  
the CD-ROM drive.  
2. Click Start => Settings => Control Panel => Display => Settings => Configuration =>  
Change graphics card => Floppy disk to open a path request dialog box. Select  
Browse and specify the following path:  
CD-LW:\SBC8260\DRIVER\VGA\Nt40.129 \OEMSETUP.INF  
3. Select OK to switch to the graphics drivers menu and select the following driver from  
the list and confirm with OK:  
Chips Video Accelerator (65545/48/50/54/55 68554 69000)  
4. To confirm the warning message, click Yes.  
5. After you have finished specifying the settings, close the Display option box and  
restart Windows NT.  
Caution  
Remove the CD-ROM from the drive.  
7-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7
6. Click Control Panel => Display => Settings and select the desired screen resolution.  
Max. resolution:  
800x600 (12" Display)  
1024x768 (15" Display)  
1280x1024 (18" Display)  
16 million colors (12" Display)  
64k colors (15" Display)  
64k colors (18" Display)  
Max. color at highest resolution:  
7. To confirm the error message, click OK.  
TouchScreen Driver Installation  
You will find drivers for the TouchScreen on the supplied "TouchTools CD from Elo  
TouchSystems.  
Caution  
During driver installation make sure that the TouchScreen is  
attached to the COM 4 (IRQ 10) serial port.  
Installation is performed as follows:  
1. Start up the computer  
2. Insert the TouchTools CD. The CD automatically starts the setup routine. If the  
Autostart function is deactivated, start the ELOCD.EXE program from main directory  
of the CD.  
3. After automatic startup, initiate driver installation by selecting the command Install  
MonitorMice for Windows NT 4.0.  
4. Follow the on-screen instructions and confirm the license conditions.  
5. Select the Single Monitor and COM4 settings and restart Windows NT by clicking OK.  
6. After Windows NT has restarted, calibrate the TouchScreen by touching the sequence  
of crosses as they appear on the screen. If the cursor movement corresponds to your  
finger movement across the TouchScreen, select OK.  
Note: The COM port is incorrectly displayed in the driver message.  
Note: The TouchScreen and PS/2 mouse can be used at the same time.  
GFK-2023C  
Chapter 7 Driver Installation  
7-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7
UDMA Driver Installation  
To ensure that the hard disk and CD-ROM drive run at maximum speed, the UDMA driver  
for the VIA chip set must be installed. The driver can be found on the “SBC Drivers,  
Utilities & User Manuals” CD. Installation is performed as follows:  
1. Switch on the PC and after the system has booted up, insert the SBC Drivers CD in  
the drive.  
2. Click Start => Run => Browse to run the following program  
CD-LW:\Utilities and drivers\VIA\CHIPSET Driver V424\SETUP.EXE  
3. Follow the on-screen instructions, install the driver and confirm that you want to restart  
the computer.  
Caution  
Remove the CD-ROM from the drive.  
4. After restarting Windows NT, the following driver is listed in Start => Settings =>  
Control Panel => SCSI Adapter: VIA bus master IDE drivers  
5. Click Start => Settings => Control Panel => SCSI Adapter => Add driver and remove  
any drivers that were not started.  
Softkeyboard Driver Installation  
To be able to use the five buttons on the front panel and to enter data using the software  
keyboard and TouchScreen, you need to install the software keyboard driver from the  
supplied disk. Installation is performed as follows:  
Caution  
For Windows NT version 4.0, do not install the driver unless Service  
Pack 5 or higher has been installed because there may be operating  
problems with earlier versions.  
1. Switch on the PC and insert the Drivers floppy after the boot.  
2. Click Start => Run => Browse to run the following program from the supplied floppy  
disk  
Soft-Keyboard_Vxx.exe  
3. Follow the on-screen instructions, install the driver, specify the language and confirm  
that you want to restart the computer.  
7-4  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7
Regional Settings  
You can subsequently adapt the key assignment of your virtual keyboard to the standard  
layouts of other countries. The settings are stored in an INI file. To change the settings,  
you will need to modify the file in a text editor such as NotePad. This can be done as  
follows:  
1. Start the text editor and open the SOFTKEY.INI file from the following directory:  
C:\Program Files\ADS-TEC\SOFT-KEYBOARD  
2. The available keyboard layouts and relevant parameters are listed in the initial section  
under Long version code.  
3. In the program section under [Common] in the Long version parameter, replace the  
code entered after the equals sign with the desired code and save the file as a text file  
with the same name.  
4. Open the software keyboard and press the Ctrl, Alt and F11 buttons one after the  
other. To confirm, click OK. The settings are then immediately applied.  
Note: You can make further alterations to the default settings of the software keyboard.  
Information on altering the settings can be found in the README file on the floppy  
disk.  
Read/Write CD-ROM Utilities  
Installation and application instructions for copying files to a write-able CD are provided  
with the supplied CD Writer Utilities.  
GFK-2023C  
Chapter 7 Driver Installation  
7-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Technical Data  
Chapter  
8
Monitor System  
IC5002/BC5002  
TFT LC-Display  
IC5005/BC5005  
IC5008/BC5008  
Display:  
Diagonal:  
307.4 mm (12.1")  
SVGA (800 x 600)  
383.5 mm (15.1")  
XGA (1024 x 768)  
459.7 mm (18.1")  
Resolution (Pixel):  
VGA controller:  
SXGA (1280 x 1024)  
(AGP)  
(AGP)  
(AGP)  
2MB SDRAM  
2MB SDRAM  
4MB SDRAM  
Colors:  
256K  
64K  
64K  
Brightness:  
300 cd/m² (downward  
adjustable)  
400 cd/m² (downward  
adjustable)  
250 cd/m² (downward  
adjustable)  
Note: Back-lighting systems are consumable parts and are therefore not covered by the  
warranty.  
Industrial PC  
IC5002/BC5002  
IC5005/BC5005  
IC5008/BC5008  
Bus/Slot-CPU:  
Processor:  
RAM:  
Passive PCI/ISA-Bus / All in One Slot-CPU with FCPGA-Socket  
1.0 GHz or greater (Optional: PIII 1.4 GHz. FSB 133)  
256 MB SDRAM (1 DIMM Slot)  
Storage:  
Hard disk min. 40 GB (3.5" UDMA)  
3.5" Floppy disk  
5.25" CD-ROM (Optional: CD-RW)  
Ports:  
a. COM1/2 (RS232 16550 compatible)  
b. COM3 (RS232 16450 compatible)  
c. LPT1  
d. Keyboard PS/2  
e. Mouse PS/2  
f. Monitor  
Two USB  
Two 10/100BaseT (RJ45. 10/100Mbit full duplex)  
Slots:  
Two shared ISA/PCI  
Two shared ISA/PCI  
one PCI  
Two shared ISA/PCI  
one PCI  
Power supply:  
100—240 VAC, 100 watt, 50 – 60 Hz, Auto sense  
Power  
consumption:  
48 watt (typical)  
60 watt max.  
54 watt (typical.)  
62 watt max.  
67 watt (typical.)  
75 watt max.  
GFK-2023C  
8-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8
Expansion Cards  
The maximum power consumption of additional expansion cards should not exceed 20  
watts to avoid overheating.  
The IC5005/BC5005 and IC5008/BC5008 models support full length cards size (339 mm).  
The IC5002/BC5002 models support up to 290 mm cards size (3/4 ISA size).  
Dimensions  
IC5002/BC5002  
IC5005/BC5005  
IC5008/BC5008  
Dimensions  
(W x H x D):  
330 x 268 x 183 mm  
390 x 312 x 156 mm  
442 x 371 x 160 mm  
Mounting depth: 177 mm +  
50 mm for cooling top  
150 mm +  
50 mm for cooling top  
and bottom  
154 mm +  
50 mm for cooling top  
and bottom  
and bottom  
30 mm for cooling on  
sides  
30 mm for cooling on  
sides  
30 mm for cooling on  
sides  
Weight:  
6.9 Kg  
8.3 Kg  
10.7 Kg  
Environmental Specifications  
Temperature  
Operating: 0—40°C  
Storage: -20—60°C  
Humidity  
Shock:  
Operating : 10—85% Non condensing  
Storage: 10—85% Non condensing  
Operating 15G equivalent, 11ms, 3 axis pos. and neg.  
Non-operating 30G Reference IEC 68-2-27.  
Vibration:  
Operating: 1G, 5 to 9 Hz; 1.0g 9 to 150 Hz.  
Non-operating: 2.5G, Reference IEC 68-2.  
Agency Approvals  
UL 1604 Class 1 Div 2  
CE  
Enclosure Protection  
Noise Immunity  
NEMA 4 (IP 65)  
Electrostatic Discharge ESD EN 61000-4-2  
Radiated Electromagnetic RF Fields EN 61000-4-3, ENV 50204  
Fast transients BURST EN 61000-4-4  
(acc. To EN 50082-2)  
Conducted Electromagnetic RF-Fields EN 61000-4-6, ENV 50141  
Emission  
RF voltage EN 55011, EN 55022  
RF fields EN 55011, EN 55022  
(acc. To EN50081-2)  
Standards  
The IC500x product models meet the test requirements for the CE mark under  
European test standards EN 55022 and EN 50082-2  
The IC500x meets the test requirements of DIN EN 60950 (VDE0805. IEC950)  
"Safety of information processing equipment "  
8-2  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8
Port Configurations  
Port  
IRQ  
Addresses  
COM1  
4
3
3F8h  
2F8h  
3E8h  
2E8h  
378h  
COM2  
COM3  
5
COM4 (Touch)  
LPT  
10  
7
Pin Assignments  
Keyboard/Mouse (6-pin mini-DIN PS/2 socket)  
Pin Number  
Signal name  
1
2
3
4
5
6
Data  
NC  
GND  
+5V  
Clock  
NC  
COM1/2/3 Serial Port (9 pin socket)  
Pin-Number  
Signal name  
1
2
3
4
5
6
7
8
9
DCD  
RxD  
TxD  
DTR  
GND  
DSR  
RTS  
CTS  
RI  
GFK-2023C  
Chapter 8 Technical Data  
8-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8
LPT1 Parallel Port (25-pin D-Sub socket)  
Pin-Number  
Signal name  
STROBE  
Pin-Number  
Signal name  
1
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
-Auto Form Feed  
-ERROR  
-Initialize  
-Printer Select In  
GND  
2
Data 0  
3
Data 1  
4
Data 2  
5
Data 3  
6
Data 4  
GND  
7
Data 5  
GND  
8
Data 6  
GND  
9
Data 7  
GND  
10  
11  
12  
13  
-ACK  
GND  
Busy  
GND  
Paper Empty  
Print select  
GND  
CRT Analog Monitor Connector (15-pin HD-Sub socket)  
Pin-Number  
Signal name  
Red  
Pin-Number  
Signal name  
1
2
3
4
5
6
7
8
9
NC  
Green  
Blue  
10  
11  
12  
13  
14  
15  
Sync-GND  
NC  
NC  
DDC-Data  
H-Sync  
V-Sync  
DDC-Clock  
Sync-GND  
AGND  
AGND  
AGND  
Power Input (cable socket)  
The power supply input to the industrial computer uses a standard IEC cable, which is  
provided with the unit.  
Pin  
Signal  
Outside  
Center  
Outside  
100—240 VAC  
ground  
100—240 VAC  
8-4  
Intelligence Panel PC User’s Manual – August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
BIOS Settings  
BIOS settings are available through the GE Fanuc web site URL http://gefanuc.com/.  
Unit Troubleshooting  
For current troubleshooting and frequently asked questions, go to the GE Fanuc web site  
Touchscreen Troubleshooting  
The ACCU.PDF file in the \Docs\Manuals directory on the “Drivers” CD supplied for the  
Touchscreen contains a user manual in Adobe Acrobat format. You will need Acrobat  
Reader installed on your system to be able to view the manual (Acrobat Reader is  
included on the CD).  
The “Troubleshooting” sections in the manual tell you how to check the drivers in the  
event of a malfunction of the Touchscreen.  
GFK-2023C  
Chapter 8 Technical Data  
8-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
G
A
Graphics driver, 7-2  
Air flow, 3-1  
Application software  
installing, 5-4  
Auto logon, 5-2  
H
Hard disk, 6-4  
Hardware monitoring, 6-3  
Hazardous locations installation, 3-6  
B
BIOS settings, 8-5  
I
Bundled solutions, 1-2  
I/O Port Range Table  
for legacy expansion cards, 4-4  
Image recovery, 5-5  
Industrial PC  
C
Calibration  
touchscreen, 5-4  
technical data, 8-1  
CD-ROM drive, 6-4  
CIMPLICITY Machine Edition, 1-2  
Control drawing CD-E219479  
nonincendive field wiring, 3-7  
Control keys, 6-1  
Installation, 3-2  
application software, 5-4  
graphics driver, 7-2  
legacy cards, 4-3  
modules, 4-1  
network adapter driver, 7-1  
power cable, 3-6  
softkeyboard, 6-2  
D
site, 2-1  
Slot cover plates, 4-2  
Softkeyboard driver, 7-4  
touchscreen driver, 7-3  
UDMA driver, 7-4  
Damage  
inappropriate use, 2-2  
transportation, 2-2  
Dimensions, 8-2  
Drivers  
Installing application software, 5-4  
Intelligence Panel  
accessories, 1-5  
graphics, 7-2  
network adapter, 7-1  
softkeyboard, 7-4  
touchscreen, 7-3  
installation, 3-1  
key features, 1-1  
ports, 6-5  
shutting down, 5-4  
standard features, 1-4  
troubleshooting, 8-5  
IRQs, for legacy cards, 4-3  
E
Electrostatic discharges, avoiding, 4-1  
Environmental specifications, 8-2  
Expansion cards  
K
installation, 4-2  
technical data, 8-2  
External keyboard, 6-2  
External monitor, 6-7  
Keyboard  
softkeyboard, 6-2  
L
F
LEDs  
hardware monitoring, 6-3  
PWR, 6-3  
Features  
overview, 1-1  
Field image recovery disk, 5-5  
Field wiring  
Legacy ISA cards, 4-3  
Login recommendation, 5-4  
nonincendive, 3-7  
Floppy disk drive, 6-4  
GFK-2023C  
Index-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
pin assignments, 8-3  
port configurations, 8-3  
standards, 8-2  
M
Machine Edition, 1-2  
Modules  
Technical support, 1-4, 8-5  
Touchscreen, 6-3  
calibration, 5-4  
installation, 4-1  
Monitor system  
technical data, 8-1  
troubleshooting, 8-5  
Troubleshooting  
Intelligence Panel, 8-5  
touchscreen, 8-5  
N
Network adapter driver, 7-1  
Networking, 6-6  
U
Nonincendive field wiring, 3-7  
UDMA driver, 7-4  
USB port connections  
Nonincendive field wiring, 3-7  
O
Operating system  
recovery, 5-5  
W
Warranty and repairs, 2-2  
Windows 2000 systems  
setting up, 5-3  
P
Windows NT systems  
setting up, 5-2  
Pin assignments, 8-3  
Port configurations, 8-3  
Ports, 6-5  
Power cable installation, 3-6  
Power supply, 6-7  
R
Read/write CD-ROM utilities, 7-5  
Recovery, image, 5-5  
Repairs, 2-2  
Return authorization, 2-2  
S
Setting up Windows 2000 systems, 5-3  
Setting up Windows NT systems, 5-2  
Shutting down the computer, 5-4  
Slot cover plates, 4-2  
Softkeyboard, 6-2  
Standards, 8-2  
Support, 1-4  
T
Technical data  
dimensions, 8-2  
environmental specifications, 8-2  
expansion cards, 8-2  
Industrial PC, 8-1  
monitor system, 8-1  
Index-2  
Intelligence Panel PC User's Manual–August 2003  
GFK-2023C  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Excalibur electronic Games FX203 User Manual
Field Controls Air Cleaner UV 16 24 User Manual
Fisher Paykel Cooktop CG363ML User Manual
Focal Car Speaker 165 KR User Manual
Franklin Industries LLC Refrigerator FC 380 Series User Manual
Frigidaire Cooktop FFGC3015LB User Manual
Garmin GPS Receiver StreetPilot i2 User Manual
GE Clothes Dryer DDC User Manual
GE Washer Dryer WHSB8000 User Manual
Global Machinery Company Drill DP21 User Manual