GE Fanuc Automation
Industrial Computers
Intelligence Panel PC
Models IC5002, IC5005, IC5008,
BC5002, BC5005, BC5008
User's Manual
GFK-2023C
August 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
Content of This Manual
This manual describes the features and operation of the following industrial computer
products:
Model
Features
Model
Features
IC5002
IC5005
IC5008
12.1" Flat panel display
BC5002
12.1" Flat panel display
with bundled software
15" Flat panel display
18" Flat panel display
BC5005
BC5008
15" Flat panel display
with bundled software
18" Flat panel display
with bundled software
Related Publications
GFK-1868
GFK-1180
CIMPLICITY Machine Edition Getting Started Manual
CIMPLICITY HMI Plant Edition Base System User's Manual (2 vols)
GFK-2023C
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Chapter 1
Product Features .................................................................................................1-1
Key Features.....................................................................................................1-1
Bundled Solutions..............................................................................................1-2
CIMPLICITY Machine Edition (ME) Bundle..................................................1-2
HMI/SCADA Bundles...................................................................................1-2
Technical Support..............................................................................................1-4
Standard Features.............................................................................................1-4
Contents of the Intelligence Panel PC Package.................................................1-5
Chapter 2
Chapter 3
Safety Instructions...............................................................................................2-1
Installation Site..................................................................................................2-1
Damage Resulting from Inappropriate Use........................................................2-2
Warranty and Repairs........................................................................................2-2
Transportation Damage.....................................................................................2-2
Installation ...........................................................................................................3-1
Installation Procedures ......................................................................................3-2
Hazardous Locations Installation.......................................................................3-6
Power Cable Installation Instructions ...........................................................3-6
Nonincendive Field Wiring Control Drawing CD-E219479
for USB Port Connections..................................................................................3-7
Chapter 4
Chapter 5
Installing Plug-in Modules..................................................................................4-1
Avoiding Electrostatic Discharges......................................................................4-1
Installing Additional Modules .............................................................................4-1
Installing Expansion Cards ................................................................................4-2
Configuring Expansion Cards (Legacy ISA Only)...............................................4-3
Reserving IRQs for ISA Cards in the BIOS ..................................................4-3
System Operation ................................................................................................5-1
Initial Startup Procedure ....................................................................................5-1
System Startup for Windows NT Units...............................................................5-2
System Startup for Windows 2000 Units............................................................5-3
Login Recommendation.....................................................................................5-4
Installing Application Software...........................................................................5-4
Touchscreen Calibration....................................................................................5-4
Shutting Down the Computer.............................................................................5-4
Image Recovery ................................................................................................5-5
Chapter 6
Controls ................................................................................................................6-1
Control Keys......................................................................................................6-1
Softkeyboard .....................................................................................................6-2
GFK-2023C
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
External Keyboard.............................................................................................6-2
Front Panel LEDs ..............................................................................................6-3
CIMPLICITY ME Template for Hardware Monitoring..........................................6-3
TouchScreen.....................................................................................................6-3
Mouse ...............................................................................................................6-4
Hard Disk...........................................................................................................6-4
Floppy Disk Drive ..............................................................................................6-4
CD-ROM Drive ..................................................................................................6-4
Ports..................................................................................................................6-5
Networking ........................................................................................................6-6
Connecting an External Monitor.........................................................................6-7
Power Supply ....................................................................................................6-7
Chapter 7
Driver Installation ...............................................................................................7-1
Network Adapter Driver Installation....................................................................7-1
Graphics Driver Installation................................................................................7-2
TouchScreen Driver Installation.........................................................................7-3
UDMA Driver Installation ...................................................................................7-4
Softkeyboard Driver Installation.........................................................................7-4
Read/Write CD-ROM Utilities.............................................................................7-5
Chapter 8
Technical Data .....................................................................................................8-1
Monitor System..................................................................................................8-1
Industrial PC......................................................................................................8-1
Expansion Cards ...............................................................................................8-2
Dimensions........................................................................................................8-2
Environmental Specifications.............................................................................8-2
Standards..........................................................................................................8-2
Port Configurations............................................................................................8-3
Pin Assignments................................................................................................8-3
BIOS Settings....................................................................................................8-5
Unit Troubleshooting..........................................................................................8-5
Touchscreen Troubleshooting ...........................................................................8-5
vi
Intelligence Panel PC User's Manual–August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Figure 3-1. IC5002/BC5000 Installation Diagram ........................................................................3-3
Figure 3-2. IC5005/BC5005 Installation Diagram ........................................................................3-4
Figure 3-3. IC5008/BC5008 Installation Diagram ........................................................................3-5
Figure 3-4. Cable Clamp Mounting for Power Cable ...................................................................3-6
Figure 6-1. Front USB Port, All Units...........................................................................................6-5
Figure 6-2. Expansion and Communications Ports, 12.1" Intelligence Panel...............................6-5
Figure 6-3. Expansion and Communications Ports, 15" and 18" Intelligence Panels...................6-6
GFK-2023C
Contents
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Table 3-1. Critical Dimensions for Installation .............................................................................3-2
Table 4-1. Intelligence Panel I/O Port Range Table ....................................................................4-4
viii
Intelligence Panel PC User's Manual–August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Features
Chapter
1
The Intelligence Panel industrial PC is designed to meet the demands of advanced control
and monitoring architectures. All GE Fanuc industrial computers meet industrial
requirements for factory automation applications, including extended temperature, shock
and vibration, and NEMA 4 sealed front panels. Coupling the industrial packaging with the
latest in processor technology and state-of-the-art flat-panel displays, this industrial PC
delivers outstanding performance to the factory floor.
Available in 12", 15" or 18" flat panel displays with active matrix Thin Film Transistor (TFT)
technology, the Intelligence Panel PC provides installation flexibility and wide viewing
angles for the most demanding industrial applications. Intelligence Panel PC is available
as a stand-alone product, or bundled with HMI/Control or HMI/SCADA software offerings.
Key Features
■
■
Standard model: 1.0 GHz CPU, or greater, 256 MB RAM with CD ROM (read only)
Performance model: 1.4 GHz CPU, or greater, 256 MB RAM with Read/Write CD
ROM
■
■
■
■
■
■
40 GB hard drive
12”, 15” or 18” active matrix TFT Touch Screen displays
Two independent 10/100 base-T Ethernet ports
Two or three ISA/PCI expansion slots (open) – Standard and Performance models
PS/2 mouse, PS/2 keyboard, USB ports, three serial ports, one parallel port
Five system-level software integration keys (Soft keyboard, Right mouse click,
brightness control. etc.)
■
■
■
System hardware monitoring (temperature, fan)
CE marked; UL 1604 Certification; NEMA 4
Operating System (OS) Recovery disk
GFK-2023C
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Bundled Solutions
The Intelligence Panel PC is available as a bundled system with the HMI or Control
application software of your choice, such as CIMPLICITY® HMI, Intellution iFIX, or
CIMPLICITY Machine Edition, launched from Windows NT® or Windows® 2000 operating
systems. Whatever your choices, powerful processors with PCI and ISA backplanes are
standard in every Intelligence Panel PC. To save you time and money, GE Fanuc
integrates and tests the powerful hardware and software combination on the Intelligence
Panel PC at our factory.
The Intelligence Panel PC fits seamlessly into your control application and accommodates
your ever-changing industrial requirements. End users, OEM, and system integrators will
see a single integrated hardware and software platform that provides a scalable
computing platform from the factory floor devices to the business enterprise at a lower
cost.
CIMPLICITY Machine Edition (ME) Bundle
The Intelligence Panel PC bundled with Machine Edition software offers a true out-of-the-
box Web-enabled solution for machine and process level HMI and PC-based control
applications. Incorporating a single user interface, Machine Edition hosts several
development and runtime engines within a common environment. Operator interface and
PC-based motion control programming are just a few of the included components.
Machine Edition comes with run-time and development software. There are two options
available:
■
CIMPLICITY Machine Edition View Run-time & Development (also known as View
Station )
■
CIMPLICITY Machine Edition Control & View Run-time Only, as well as Run-time &
Development (also known as Control Station )
HMI/SCADA Bundles
GE Fanuc’s Intelligence solutions are the ideal platform for visualization, automation and
control. iFIX and CIMPLICITY HMI software products combine our rugged hardware units
with our powerful software applications and are designed to uniquely suit your needs for
process or discrete environments.
iFIX, with an information rich automation oriented Function Block Database combined with
a robust and extensible graphics environment, is an ideal option for meeting all your
supervisory control and data acquisition needs.
iFIX functionality includes features created specifically to address the electronic signature
and advanced audit trail needs of regulated industries. This added functionality empowers
you to introduce new levels of security and accountability into any application in your
organization, regardless of industry. Some markets ideally suited to iFIX include
water/wastewater, food and beverage, pharmaceutical, metals, oil and gas, mining and
others with a process orientation.
CIMPLICITY HMI provides advanced functionality that establishes a solid foundation for a
robust, powerful HMI interface and is the best option for applications with a greater
1-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
1
discrete manufacturing orientation. A true client/server architecture and open-system
design offers fast, easy integration. CIMPLICITY HMI gives you the ability to grow from a
single computer node to a plant-wide monitoring and control system providing real-time
information from the factory floor to all levels of the enterprise.
CIMPLICITY HMI offers powerful operator interface and machine control functionality.
Several markets and applications that are ideally suited to CIMPLICITY HMI include
automotive, aerospace, plant floor, HMIs, discrete manufacturing, machining,
semiconductor, CNC, Motion Control, and Consumer Packaged Goods among others.
Both products use the latest web technologies to provide you with visibility into the key
metrics you need to run your manufacturing operations efficiently and effectively. This
data can made available to one of the many web-enabled display devices on the market
today. Whether it is a standard web browser, hand-held PDA, wireless bar code reader or
industrial hardened CE device, you get real-time access to the important information
needed to operate your business.
GFK-2023C
Chapter 1 Product Features
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Technical Support
GE Fanuc provides a single resource for all your services and support needs including
technical software support, product training, and complete application consultation and
development services.
Phone: 1-800-433-2682 (1-800-GEFANUC)
e-mail: [email protected]
Standard Features
IC5002
IC5005
IC5008
TFT LC-Color Touch Display
383.5 mm (15.1")
Display
307.4 mm (12.1")
459.7 mm (18.1")
Diagonal
SVGA (800 x 600)
XGA (1024 x 768)
SXGA (1280 x 1024)
Resolution (Pixel)
VGA controller
(AGP 1x)
2MB SDRAM
(AGP 1x)
2MB SDRAM
(AGP 1x)
4MB SDRAM
256k
64k
64k
Colors
300 cd/m²
400 cd/m²
250 cd/m²
Brightness
Touch Screen
Analog. 5 wire resistive with serial interface internal connected to COM4
1. Soft key board via Touch Screen
2. Task changes (Alt + Esc)
3. Hot-Key
Front key
functions
4. Right mouse button
5. Display adjustment brightness
All in Passive PCI/ISA bus slot CPU with FCPGA-Socket for Intel processor
1.0 GHz (Optional: PIII 1.4 GHz. FSB 133)
Slot-CPU
Processor
RAM
256 MB SDRAM (1 DIMM Slot)
Hard disk min. 40 GB minimum (3.5" UDMA)
3.5" Floppy disk
Storage
5.25" CD-ROM (Optional: CD-RW)
COM1/2/3 (RS232)
LPT1
Ports
Keyboard PS/2
Mouse PS/2
CRT Monitor
Two USB (one front, one side)
Two 10/100BaseT (RJ45, 10/100Mbit full duplex)
Network
Slots
Two shared ISA/PCI
Two shared ISA/PCI
One PCI
Two shared ISA/PCI
One PCI
100—240 VAC, 50—60Hz, 100 watt
Power supply
48 watt (typical)
60 watt max.
54 watt (typical)
62 watt max.
67 watt (typical)
75 watt max.
Power
consumption
NEMA4/12; Front IP65
Protection
1-4
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Contents of the Intelligence Panel PC Package
Check that one of each of the following items is included in the package with your
Intelligence Panel PC:
■
■
■
■
■
■
■
■
■
■
■
Industrial flat panel PC
Conventional power cable and plug
Hazardous Environment power cable and plug mounting kit
User manual
Axiom CD: SBC Drivers, Utilities & User Manuals
ELO TouchSystems CD
Soft Keyboard Floppy Disk
Device panel mounting kit
NERO CD: CD read/write driver
Media Kit for License Software
Operating System Recovery floppy disk
GFK-2023C
Chapter 1 Product Features
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Instructions
Chapter
2
Warning
This equipment carries electric currents and contains highly-
sensitive components. Other than plugging in additional cards or
modules, you should not attempt modifications to the unit. If other
modifications need to be made, the manufacturer or an authorized
service agent must be contacted. The unit must be switched off at
the main power supply and the power cable disconnected during
such work. Suitable precautions must be taken to avoid electrostatic
discharge on contact with components. If an unauthorized person
opens the product case, danger to the user may arise and the
warranty will be void.
Caution
To prevent damage to the unit, do not attempt to connect leads
(power supply and port cables) unless the unit is switched off.
Installation Site
The Intelligence Panel is designed for installation in a metal cabinet. The ambient conditions
specified in chapter 8, “Technical Data” must be maintained. Installation in an environment
not specified in Technical Data, for example exposed to extended temperatures or at
extreme altitudes, may void the warranty.
Warning
When installing the unit in an environment where there is the
potential for flammable gases, vapors or liquids to be present, the
power cable must be secured to the unit using the enclosed cable
clamp kit. In addition, the power cable must have the male plug
removed and be permanently hard-wired to the AC source. For
details, refer to “Hazardous Locations Installation” in chapter 3.
GFK-2023C
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Damage Resulting from Inappropriate Use
If the Intelligence Panel displays signs of damage caused by inappropriate
operating/storage conditions, mounting, or incorrect handling, the unit must be taken out of
use immediately and secured against unintentional operation.
Warranty and Repairs
Repairs under warranty may only be made by the manufacturer or by agents authorized by
the manufacturer.
For return authorization, contact 1-800-432-7521 Customer Service. Be prepared to provide
delivery date, product model, customer order number, unit serial number, and reason for
return request.
Caution
Units must be returned to the factory in the original shipping
container. If you do not have the original shipping container, contact
GE Fanuc Customer Care to order a new shipping container. . The
part numbers are 44B714940-001R01 (Carton) and 44B714939-
001R01 (Insert). For proper shipping one carton and two inserts are
required. If the units are not returned in the original shipping
container the warranty is voided.
Transportation Damage
Warning
If the product has incurred obvious damage during transportation,
do not apply power
If the product has incurred obvious damage during transportation, you should avoid applying
power. Obvious transport damage should be reported to the supplier immediately. Less
obvious damage that becomes evident in the early operation of the product must be
reported within five days of the initial delivery for consideration as transportation damage.
2-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Chapter
3
Intelligence Panel PCs are designed for installation in switchboard panels and cabinet
doors. To facilitate installation and access to connectors, switchboard panels and
consoles must be accessible from the rear. The unit can be installed in switchgear
cubicles or cabinets with wall thicknesses of 2mm to 13mm (0.079 – 0.5 inches). For
optimum sealing with the cabinet face, the recommended wall thickness is
3mm (0.118 inches).
Air Inlets and outlets must have at least 25mm (approx. 1.0 inch) of space around them
and not be obstructed. Adequate airflow around the exterior of the unit is important to the
interior temperature of the unit. Two fans are used to create air flow through the industrial
computer to maintain a correct working temperature.
Caution
Only correct mounting ensures front-side NEMA and IP65 protection
Caution
The IC5005/BC5005 and IC5008/BC5008 units must be installed and
operated in a vertical position to ensure the correct operating
position of the CD-ROM drive.
Caution
Viewed from the front, there must be sufficient space (132 mm or
5.20 in. minimum) to the left of the units to allow the CD-ROM drive
drawer to open.
GFK-2023C
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Installation Procedures
1. Make a cut-out (corresponding to size of the particular unit) in the switchgear panels
or cabinet doors (see Figures 3-1 through 3-3).
2. Insert the unit into this cut-out from the front.
3. Insert the mounting screws together with mounting blocks in the slots provided in the
metal cover and tighten all screws evenly until the surround panel covers the cut-out
securely. Maximum torque is 0.25 N-m (2.2 lbf-in).
Caution
Over tightening the screws will cause irreparable damage to the
front panel and break the touch screen itself.
Connect the provided power cord to the AC power supply. If additional grounding to a
grounding screw is desired, use 14 AWG gauge wire minimum.
Table 3-1. Critical Dimensions for Installation
Dimension
IC5002
IC5005
IC5008
BC5002
BC5005
BC5008
Cover (W x H)
313 x 252mm
23.3 x 9.9 in.
373.6 x 295.6 mm
14.7 x 11.6 in.
426 x 355mm
16.8 x 14.0 in.
Cutout (recess) (W x
H)
318 x 256mm +1.0mm 376 x 299mm +1.0mm 428 x 358mm +1.0mm
12.5 x 10.1 in. + 0.04
in.
14.8 x 11.8 in. + 0.04
in.
16.9 x 14.0 in. + 0.04
in.
Space required for
ventilation
Minimum 50mm (2 in) clearance at top and bottom of the unit. Minimum
30mm (1.2 in.) at sides.
Note additional side space consideration is required for models with CD-
ROM, depending on cabinet design. Viewed from the front, there must be
sufficient space (132 mm or 5.20 in. minimum) to the left of the units to
allow the CD-ROM drive drawer to open.
Mounting depth
177mm
6.97 in.
150mm
5.9 in.
154mm
6.1 in.
3-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
3
0
70
260
330
0
6x Mounting blocks M4
View from back side
Dimensions:
Cover:
Mounting depth:
Space required for cooling:
313 x 252 mm (W x H)
83 mm
Approximately 50 mm around the unit
134
158
318 x 256 mm +1,0 (W x H)
Recess:
132 mm
CD Drawer
Clearance
Outer edge of cover
268
Outer edge of recess
Outer edge of frontpanel
Figure 3-1. IC5002/BC5000 Installation Diagram
GFK-2023C
Chapter 3 Installation
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
3
0
31
186
341
390
0
8x Mounting blocks M4
View from back side
125
156
Dimensions:
Cover:
Mounting depth:
Space required for ventilation:
373,6 x 295,6 mm (W x H)
150 mm
Approximately 50 mm around the unit
Recess:
376 x 299 mm +1,0 (W x H)
132 mm
CD Drawer
Clearance
Outer edge of cover
312
Outer edge of recess
Outer edge of frontpanel
Figure 3-2. IC5005/BC5005 Installation Diagram
3-4
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
3
0
40
221
402
442
0
8x Mounting blocks M4
View from back side
Dimensions:
Cover:
Mounting depth:
426 x 355 mm (W x H)
154 mm
Approximately 50 mm around the unit
Space required for ventilation:
185,5
199,5
Recess:
428 x 358 mm +1,0 (W x H)
132 mm
CD Drawer
Clearance
Outer edge of cover
371
Outer edge of recess
Outer edge of frontpanel
Figure 3-3. IC5008/BC5008 Installation Diagram
GFK-2023C
Chapter 3 Installation
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Hazardous Locations Installation
Warning
When installing the unit in an environment where there is the
potential for flammable gases, vapors or liquids to be present the
power cable must be secured to the unit using the enclosed cable
clamp kit. In addition, the power cable must have the male plug
removed and be permanently hard-wired to the AC source.
Mounting holes for
cable clamp
Power connector
Figure 3-4. Cable Clamp Mounting for Power Cable
Power Cable Installation Instructions
1. Attach clamp to power plug with the two screws provided.
2. Plug power cable into power connector on unit.
3. Securely attach the power plug and clamp assembly to the chassis at the two screw
holes provided to the left and right of the plug.
3-6
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Nonincendive Field Wiring Control Drawing CD-E219479
for USB Port Connections
Hazardous (Classified) Location
Class I, Division 2 Groups A, B, C, and D
Front USB Port on Computer No._________________
Associated Nonincendive
Field Wiring Apparatus
(Computer)
Nonincendive Field
Wiring Apparatus
Vmax
Imax
Ci
Voc
Isc
Ca
La
Li
Notes:
1. Nonincendive Circuit Parameters:
Voc = 4.969 VDC
Isc = 2.06 A
Ca = 75 µF
La = 40 µH
2. Selected Nonincendive Field Wiring Apparatus shall satisfy the following:
Voc
Isc
Ca
La
Vmax
≤
≤
≥
≥
Imax
Ci + C cable
Li + L cable
3. If the electrical parameters of the cable are unknown, the following values may be
used:
Capacitance – 60 pF/ft
Inductive – 0.20 µH/ft
4. Nonincendive Field Wiring must be installed in accordance with Article 501.4(B)(3) of
the National Electrical Code ANSI/NFPA 70.
5. Selected Nonincendive Field Wiring Apparatus must not be connected to external
power source.
GFK-2023C
Chapter 3 Installation
3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Plug-in Modules
Chapter
4
PCI bus or ISA bus plug-in modules, such as network or field bus cards, can be installed
in the Intelligence Panel. The plug-in slots are accessed by removing the rear cover,
which is secured by cross-head screws.
Avoiding Electrostatic Discharges
Caution
The components in Intelligence Panel PCs are susceptible to
electrostatic discharge (ESD) and can be functionally damaged by
incorrect handling. The same applies to plug-in modules. It is
therefore vital that suitable precautionary measures are taken to
avoid electrostatic discharges on contact with the components.
1. Before touching components or modules, always touch a metal object with a
conductive surface that is connected to ground potential.
2. Wear a wrist strap.
3. When handling modules, only touch the edges or the module bracket, not the
components themselves.
Installing Additional Modules
Caution
To avoid a risk of electric shock, turn off power to the industrial
computer and disconnect the power supply before removing the rear
panel.
1. Switch off the Intelligence Panel and all units connected to the PC and disconnect the
PC from the power source.
2. Remove the screws from the rear panel and pick up the cover carefully.
GFK-2023C
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Caution
The rear cover is connected to the base units of the Intelligence
Panel by a plug-in ground connector and cable. Carefully remove
and orient the rear cover to avoid applying unnecessary tension on
this cable.
3. Select a free slot and remove the blank cover plate from this slot.
4. Using the precautionary measures described in “Avoiding Electrostatic Discharges,”
remove the plug-in module from its packaging, plug it into the slot and screw it
securely to the bracket.
5. When the module has been installed, refit the ground connector (if disconnected) and
replace the rear panel, ensuring that the side clips are correctly positioned.
6. Tighten the six screws on the rear panel.
Installing Expansion Cards
All the expansion slots in the system allow the card to be clamped into place using
standard PC card clamping.
•
Wear a properly functioning antistatic strap and be sure that you are fully
grounded. Never touch the card, or any components inside the computer
unless you are wearing an antistatic strap.
•
•
Any surface upon which you place the unprotected card should be static-safe,
facilitated by antistatic mats if possible.
Extra caution should be taken in cold, dry weather, when static charges can
easily build up.
Slot Cover Plates
Cover plates are fitted to each unused card position. These plates can be removed as
necessary to install new cards. Any empty slots must have a cover plate fitted, otherwise
agency approvals become invalid.
4-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Configuring Expansion Cards (Legacy ISA Only)
Caution
For most applications, an interrupt request (IRQ) or address cannot
be shared by more than one resource. If more than one resource is
set to the same IRQ or address, the application may not respond
properly and could cause your machine to lock up. Following these
instructions when installing Legacy ISA cards will prevent problems
with resource conflicts.
The controllers (Ethernet, IDE) in the slot CPU of the IPC are connected via an internal
PCI bus. This ensures that addresses and IRQs are automatically determined by the
BIOS. When making changes to the configuration or adding ISA cards:
1. Install the unit without ISA cards, switch on and read off assigned IRQs and
addresses.
2. Install additional ISA cards so that IRQs assigned to PCI are not reused (interrupt
sharing).
3. Reserve IRQs for ISA in the BIOS
Reserving IRQs for ISA Cards in the BIOS
Legacy ISA cards are the oldest standard and require memory, I/O, and IRQ settings to
be manually set on the card using jumpers, DIP switches, or a configuration program. The
card and system need to have the same hardware settings.
for IRQs.
1. Connect a keyboard, turn on the system power, and press F2 when prompted to enter
the BIOS Setup program.
2. Select Advanced, then PCI Configuration, and PCS ISA Resource Exclusion.
3. If the card requires one or more interrupts, go to an IRQ that currently reads
"Available" and change it to "Reserved" by pressing +/-. Do not use an IRQ that
already reads "Reserved."
4. If the card requires memory space, press the arrow key to return to the PCI
Configuration screen. Select PCI ISA UMB Region Exclusion. Go to a memory block
that currently reads "Available" and change it to "Reserved" by pressing +/-. Do not
use a memory block that already reads "Reserved."
5. Press ESC to exit the configuration screen. In the Exit menu, select Exit Saving
Changes and to save and exit Setup. When the screen goes blank, turn off the power.
6. If the card has jumpers or DIP switches, set them so that they match the IRQ and
memory addresses set in the BIOS Setup.
7. Set the I/O port settings of the card (if any) so that they fall within the ranges labeled
"Available" in the following table.
GFK-2023C
Chapter 4 Installing Plug-in Modules
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
4
8. If the card is set up using a configuration program, proceed with installation, run the
card’s configuration program. Set the IRQ and memory address to the same settings
as those put into BIOS Setup. Set the I/O port settings (if any) to a range labeled
“Available” in the following table.
Table 4-1. Intelligence Panel I/O Port Range Table
000-1FF
200-277
278-2FF
300-377
378-3DF
3E0-3EF
3F0-3FF
Reserved
Available
Reserved
Available
Reserved
Reserved
Reserved
4-4
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
System Operation
Chapter
5
This chapter covers the following topics:
■
■
■
■
■
■
■
Initial startup procedure
System startup for Windows NT
System startup for Windows 2000
Login
Installing Application Software
Image Recovery
Shutting Down the Computer
Initial Startup Procedure
Warning
Installation of the Intelligence Panel in hazardous locations requires
the use of a cable mounting clamp with the power connector. For
instructions for installing this clamp, refer to “Hazardous Locations
Installation” in Chapter 3.
1. Plug the power cable into the unit’s power connector and connect to the power
source.
2. Plug in the serial/parallel data transfer cables and screw the plugs to the connectors.
Caution
To prevent damage, do not attempt to connect leads unless the unit
is switched off.
Note: The data cable shield must be connected to the housing of the
push-on connector (EMC).
3. Switch on the unit and check whether any concealed damage has been caused by
incorrect transportation, incorrect operating/storage conditions or incorrect handling
(e.g. smoke coming out of the unit, etc.). If you notice any damage, switch off the unit
immediately and secure it against unintentional use.
GFK-2023C
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
5
System Startup for Windows NT Units
Connecting a PS/2 keyboard and mouse is recommended before you get started. You
need a PS/2 keyboard for convenience. An alternate approach is to use the soft keyboard
and touch panel.
1. Plug in the keyboard, PS/2 mouse (if available), and power cord.
2. Power on the unit.
3. Read the license agreement
4. TAB to your choice and press ENTER.
5. Press ENTER to start the Windows NT Setup.
6. Type your name.
7. Press the TAB key and type your company name.
8. Press ENTER.
9. Enter the Windows NT Authentication number found on your Windows NT manual.
You will need to use the TAB key to get to each number field. If correct, press ENTER.
Note: Computer names must be less than or equal to ten characters to
run CIMPLICITY HMI software. Each computer on a network
must have a unique name.
10. Enter a Computer name. This name must be different from other computer names on
the same network. Press ENTER.
Note: Your system has been set up to enable auto logon. Auto logon
allows the system to boot into Windows NT without your having to
use a keyboard to press CTRL-ALT-DEL.
11. You will be prompted for a password.
•
To use the auto logon feature, type admin for the password. Press the TAB key
and type admin in the Confirm Password box. Press ENTER.
•
•
To skip the password, press ENTER
To assign a password, type in a password, press the TAB key, and type the
password in the Confirm Password box. Press ENTER.
12. Press ENTER to continue with Windows NT Setup.
Note: The factory setting for the IP is 111.111.111.111 and for the
Subnet is 255.0.0.0. If necessary, consult your network
administrator to select appropriate addresses.
13. After completing the network setup, the system will copy files over and finalize its
setup.
14. At the end of the setup process, you will be asked to reboot the system. Press ENTER.
5-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
5
System Startup for Windows 2000 Units
Connecting a PS/2 keyboard and Mouse is recommended before you get started. You
need a PS/2 keyboard for convenience. The soft keyboard and touch panel will not work
until the Windows 2000 operating system is licensed. Therefore an external keyboard is
required to license the product.
1. Plug in the keyboard, PS/2 mouse (if available), and power cord.
2. Power on the unit.
3. Read the license agreement.
4. Select your choice and press NEXT >.
5. Choose your regional settings (US default) and press NEXT >.
6. Type your name.
7. Press the TAB key and type your company name.
8. Press NEXT >.
9. Enter your Windows 2000 Product Key found on the back of the Intelligence Panel.
When correct, press NEXT >.
Note: Computer names must be less than or equal to ten characters to run CIMPLICITY
HMI software. Each computer on a network must have a unique name.
10. Enter a Computer name. This name must be different from other computer names on
the same network. Press Next >.
11. If desired, enter an Administrator password. You will need to enter it twice to confirm.
When done, press Next >.
12. You can now set the Date, Time and Time Zone for the computer. When the
information is correct, press Next >.
13. Choose Typical settings for the factory setting of TCP/IP protocol at IP
111.111.111.111 and subnet 255.0.0.0, or, choose Custom and press Next > to
change these settings. Consult your network Administrator for your network’s
configuration settings.
14. Choose whether this computer will be on a workgroup or domain and enter the name
and press Next >.
15. After completing the network setup, the system will finalize its setup.
At the end of the setup process, you will be asked to reboot the system. Press Finish.
After restarting, you will need to configure the login settings for Windows 2000. When the
“Network Identification Wizard” dialog box appears press Next >.
The “Users of This Computer” dialog box appears.
•
If you wish to have the computer automatically log on with the administrator
account, select the “User name” pull down and choose “Administrator.” Enter the
password used in step 11 and press NEXT >. The computer will automatically log
on when it starts up.
•
If you wish to require a logon when the computer is restarted, select “Users must
enter a user name and password to use this computer” and press NEXT >. You will
then be asked for a user name and password when the computer starts up.
16. Press Finish and the setup is complete.
GFK-2023C
Chapter 5 System Operation
5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Login Recommendation
With Windows NT, if you type admin as your Administrator password, your industrial
computer will automatically log on as Administrator.
Log onto the system as Administrator when you power up the system. Doing so eliminates
the requirement to log on to CIMPLICITY when you run the CIMPLICITY Demo or any
other CIMPLICITY project that includes a user named Administrator. All CIMPLICITY
projects are configured with an Administrator user by default.
Installing Application Software
The Windows operating system and GE Fanuc software (except IC850PCT400) are
loaded onto the industrial computer at manufacture. If it is necessary to reload software,
follow the instructions in the documentation supplied with the software.
Touchscreen Calibration
1. Open Control Panel, by selecting Start, Settings, then Control Panel.
2. Select the Elo Touchscreen icon in the Control Panel window.
3. Select Calibrate in the Elo Touchscreen properties window.
4. Follow the on-screen instructions to calibrate the Touchscreen.
Shutting Down the Computer
Caution
To avoid damaging files, always shut down Windows Operating
System before removing power from your Intelligence Panel.
To shut down Windows Operating System, select the Start menu and
choose Shut Down.
5-4
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Image Recovery
The IPC features a hidden partition on the hard drive that contains an OS recovery image.
This image can be used to recover a corrupt OS.
Instructions for OS recovery:
Warning
Before attempting an Image Recovery on your unit, make sure to
record all critical settings and conduct a full back up of all software
projects and critical documents. You will also need to have your
software (CIMPLICITY software product) registration and Microsoft
Authorization Numbers handy. This process will clear all contents
from your Hard Drive and return your system to the factory
configuration.
1. Prior to Image Recovery, a standard PS/2-type keyboard should be connected to the
external keyboard port.
1. Set CMOS settings to allow the unit to start up from the floppy drive (A:)
2. Install the supplied OS Recovery Disk.
3. Start the system. Recovery begins automatically.
4. When recovery is complete, remove the floppy disk and restart the system.
5. Relicense the OS using the license label supplied.
−
−
On Windows 2000 units, the license is on the back of the unit.
On Windows NT units, the license is provided on the supplied OS packet.
MS-DOS is a registered trademark of Microsoft Corporation.
GFK-2023C
Chapter 5 System Operation
5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls
Chapter
6
Control Keys
Intelligence Panel PCs are shipped with the Windows NT or Windows 2000 operating
system installed. Additional pre-installed software includes drivers to support the virtual
keyboard. In case you need to re-install the software, CDs and floppy disks are included
with the appropriate drivers.
The five keys on the front panel are assigned the following default functions.
Opens and closes the virtual keyboard to allow character input via the
TouchScreen
With SHIFT key: No function.
Switches tasks (ALT+ESC) in Windows.
With SHIFT key: No function.
Hot Keys: Launches application - Starts the text editor (Notepad) as the default.
With SHIFT key: Increases display brightness.
Right mouse key function.
With SHIFT key: Decreases display brightness.
SHIFT key for upper case. The SHIFT key must be pressed at the same time as
the desired function key.
The general system keys can be disabled or configured to launch an application or tool
through an .ini file. For information on application instructions, see the GE Fanuc web site
Note: If the Softkeyboard is not installed, only the display setting functions are active.
Note: You can alter the default settings of the virtual keyboard. Information on altering
the settings can be found in the README file on the floppy disk.
GFK-2023C
6-1
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Softkeyboard
A virtual keyboard that allows you to enter data using the TouchScreen in a similar way to
a normal keyboard is supplied with the Intelligence Panel. If the Intelligence Panel is
delivered without an installed operating system, you can install the Softkeyboard using the
floppy disk provided (see chapter 7, “Driver Installation”). This also automatically installs
the keyboard assignment for the five keys below the display at the front.
Note: To access commands that require two keys to be pressed simultaneously on a
standard keyboard (e.g. ALT + F4), these keys have to be pressed one after the
other on the virtual keyboard. The special SHIFT, ALT and CTRL keys always have
to be pressed first.
Note: Because of programming differences in different software packages, it cannot be
guaranteed that the virtual keyboard will be compatible with all software.
Softkeyboard Controls
Increases the size of the Softkeyboard display
Decreases the size of the Softkeyboard display
Free area Moves the virtual keyboard on the screen
External Keyboard
A 6-pin mini-DIN Keyboard socket (PS/2) is located on the side of the operating console.
Industry-standard, AT-compatible quality keyboards with the appropriate connector can be
plugged into this socket. The suitability of keyboards must be checked before installation.
Note: When the virtual keyboard is displayed as active on screen, only
a limited range of controls are available on the external keyboard.
6-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Front Panel LEDs
PWR LED
When the SHIFT key is used to adjust the display settings, the LED goes out. If one of the
other four keys is also pressed, the LED flashes until the limit of the adjustment range is
reached.
The following modes are also displayed:
■
■
■
Green light:
Red light:
Indicates ready status (Power ON)
Processor fan speed too slow or stopped
Unit overheating
Red flashing:
Note: The overheating error signal has priority over fan errors and is
therefore displayed if both errors occur.
Note: To ensure that the user has noticed the error signal, the red
Overheating and Fan Speed LED signals can only be reset by
restarting the computer.
CIMPLICITY ME Template for Hardware Monitoring
When using CIMPLICITY Machine Edition or CIMPLICITY HMI, an OPC driver is provided
to monitor the PC condition through system status variables. The following features can
be monitored:
■
■
■
■
CPU Fan error
Chassis Fan error
CPU over temperature (greater than 50 degrees C)
On board NTC (-127 degree C to +127 degree C)
TouchScreen
The operating console is provided with the analog TouchScreen with serial controller,
which is connected internally to the COM4 serial port. To be able to use the TouchScreen,
the driver software must be integrated in the relevant operating system (see
“TouchScreen Driver Installation” in chapter 7).
GFK-2023C
Chapter 6 Controls
6-3
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Mouse
A Microsoft-compatible mouse with PS/2 connector can be attached to the Mouse port.
The compatibility of the mouse must be checked before use. The mouse can be used in
addition to the TouchScreen.
Note: It is recommended that you connect a PS/2 mouse to the mouse
port during installation as the TouchScreen is not yet usable. This
considerably simplifies the process of initial installation of the
operating system. The mouse can be removed later without an
error message.
Hard Disk
The hard disk is fitted to a mounting plate with vibration-damping rubber elements. A 3.5"
Ultra-DMA hard disk with commonly available capacity (minimum of 20 GB) is provided.
Floppy Disk Drive
The floppy disk drive is fitted on the left of the operating console (viewed from the front)
next to the Intelligence Panel ports.
CD-ROM Drive
The CD-ROM drive is on the left of the operating console (viewed from the front) under
and next to the Intelligence Panel ports. The CD-ROM drive cannot be opened unless the
Intelligence Panel is switched on. Pressing the Eject button activates a motor that opens
the drawer. The drawer can be closed again by pushing the drawer gently or by pressing
the Eject button.
Caution
To avoid damage to the drive, ensure that the motorized drawer is
not obstructed as it opens. (See “Installation Procedures” in
chapter 3.)
6-4
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Ports
A USB port is provided on the front of the operating console. All other ports are arranged
in the housing on the left of the operating console (viewed from the front). All ports are
labeled. For pin assignments, refer to chapter 8, “Technical Data”.
Caution
To prevent damage to the unit, do not attempt to connect leads
unless the unit is switched off.
Figure 6-1. Front USB Port, All Units
USB
COM 1
COM 3
Ethernet
COM 2
CRT
LPT 1
PS/2
PS/2 Mouse
Keyboard
Figure 6-2. Expansion and Communications Ports, 12.1" Intelligence Panel
GFK-2023C
Chapter 6 Controls
6-5
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Ethernet
COM 1
USB
CRT
COM 3
Floppy
Disk Drive
COM 2
LPT 1
PS/2
Keyboard
PS/2 Mouse
CD-ROM
Drive
PCI/ISA (2) and
ISA slots
Figure 6-3. Expansion and Communications Ports, 15" and 18" Intelligence Panels
Networking
The Intelligence Panel can be integrated into an Ethernet supporting 10 or 100 Mbit/sec.
using an appropriate network cable from the Ethernet network port (10/100Base-T).
Network architecture specifications must be observed. The CD supplied with the unit
contains drivers required for network operation, which must be installed according to the
particular operating system (see Chapter 7, “Driver Installation”).
6-6
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Connecting an External Monitor
A CRT-Multisync monitor can be operated from the 15-pin monitor connection in parallel
with the integral flat screen. The monitor must be capable of running at a minimum
horizontal frequency between 31-69 kHz, otherwise the maximum resolution of 1280 x
1024 pixels cannot be displayed.
Caution
Do not connect a standard VGA monitor (horizontal frequency 31.5
kHz) as it will be damaged by timing changeovers!
Power Supply
The Intelligence Panel is fitted with an auto-switching power supply.
•
Primary voltage 100-240 VAC (50-60 Hz)
ON/OFF switch
•
•
Power connector with surge protection (to provide protection against power surges
and spikes)
GFK-2023C
Chapter 6 Controls
6-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Driver Installation
Chapter
7
Intelligence Panel PCs are shipped from the factory with the Windows operating system
pre-installed. Depending on the product purchased, CIMPLICITY software is also
preinstalled. For configurations where no operating system is installed or the operating
system needs to be re-installed, you must perform a complete installation procedure and
set up all necessary drivers. The original CDs and a Softkeyboard floppy disk are supplied
with the unit.
Note: During installation it is recommended that you connect a PS/2 mouse to the
mouse port because the TouchScreen is not yet usable. This simplifies the
process of initial installation of the operating system. The mouse can be removed
later without an error message.
Network Adapter Driver Installation
Caution
To install the driver for the network card, the installation files from
the CD "SBC Drivers, Utilities & User Manuals" (file path:
CD:\SBC8260\DRIVER\LAN\WINNT) must be copied to the main
directory of a floppy disk.
To install the integrated network port for Windows NT:
1. Plug the network cable (TP) into the IPC and connect to the network.
2. Switch on the PC and begin installation of Windows NT 4.0.
3. Confirm the Create Connection Between Computer and Network and Connect Directly
to the Network messages.
4. Click the Select From List option and select Floppy disk.
5. Confirm the displayed path A:\ with OK.
6. In the next window select the following driver (card) and confirm with OK:
RTL8139 (A/B/C/8130) PCI Fast Ethernet Adapter.
GFK-2023C
7-1
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Caution
If selecting DHCP, the IPC must be connected to the DHCP-
supported network.
7. Click Next to define settings for the network protocol desired by the specific user and
the operating mode (default setting: (1) Auto). If selecting the TCP/IP protocol, the
DHCP mode or fixed IP address must also be selected.
8. Click Next to enter user-specific work groups and domain data.
9. Continue installing Windows NT.
Graphics Driver Installation
Since Windows NT 4.0 installation only installs a standard VGA driver supplied by the
operating system manufacturer, this needs to be replaced in order to make full use of the
capabilities of the high-resolution flat screen. The driver can be found on the "SBC
Drivers, Utilities & User Manuals CD). Installation is performed as follows:
Caution
For Windows NT, do not install the driver unless Service Pack 3 or
higher has been installed since in earlier versions Windows does
not support the AGP interface of the graphics card. Do not install the
driver during initial installation of the operating system.
1. Switch on the PC and after the system has booted up, insert the SBC Drivers CD in
the CD-ROM drive.
2. Click Start => Settings => Control Panel => Display => Settings => Configuration =>
Change graphics card => Floppy disk to open a path request dialog box. Select
Browse and specify the following path:
CD-LW:\SBC8260\DRIVER\VGA\Nt40.129 \OEMSETUP.INF
3. Select OK to switch to the graphics drivers menu and select the following driver from
the list and confirm with OK:
Chips Video Accelerator (65545/48/50/54/55 68554 69000)
4. To confirm the warning message, click Yes.
5. After you have finished specifying the settings, close the Display option box and
restart Windows NT.
Caution
Remove the CD-ROM from the drive.
7-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
7
6. Click Control Panel => Display => Settings and select the desired screen resolution.
Max. resolution:
800x600 (12" Display)
1024x768 (15" Display)
1280x1024 (18" Display)
16 million colors (12" Display)
64k colors (15" Display)
64k colors (18" Display)
Max. color at highest resolution:
7. To confirm the error message, click OK.
TouchScreen Driver Installation
You will find drivers for the TouchScreen on the supplied "TouchTools CD from Elo
TouchSystems.
Caution
During driver installation make sure that the TouchScreen is
attached to the COM 4 (IRQ 10) serial port.
Installation is performed as follows:
1. Start up the computer
2. Insert the TouchTools CD. The CD automatically starts the setup routine. If the
Autostart function is deactivated, start the ELOCD.EXE program from main directory
of the CD.
3. After automatic startup, initiate driver installation by selecting the command Install
MonitorMice for Windows NT 4.0.
4. Follow the on-screen instructions and confirm the license conditions.
5. Select the Single Monitor and COM4 settings and restart Windows NT by clicking OK.
6. After Windows NT has restarted, calibrate the TouchScreen by touching the sequence
of crosses as they appear on the screen. If the cursor movement corresponds to your
finger movement across the TouchScreen, select OK.
Note: The COM port is incorrectly displayed in the driver message.
Note: The TouchScreen and PS/2 mouse can be used at the same time.
GFK-2023C
Chapter 7 Driver Installation
7-3
Download from Www.Somanuals.com. All Manuals Search And Download.
7
UDMA Driver Installation
To ensure that the hard disk and CD-ROM drive run at maximum speed, the UDMA driver
for the VIA chip set must be installed. The driver can be found on the “SBC Drivers,
Utilities & User Manuals” CD. Installation is performed as follows:
1. Switch on the PC and after the system has booted up, insert the SBC Drivers CD in
the drive.
2. Click Start => Run => Browse to run the following program
CD-LW:\Utilities and drivers\VIA\CHIPSET Driver V424\SETUP.EXE
3. Follow the on-screen instructions, install the driver and confirm that you want to restart
the computer.
Caution
Remove the CD-ROM from the drive.
4. After restarting Windows NT, the following driver is listed in Start => Settings =>
Control Panel => SCSI Adapter: VIA bus master IDE drivers
5. Click Start => Settings => Control Panel => SCSI Adapter => Add driver and remove
any drivers that were not started.
Softkeyboard Driver Installation
To be able to use the five buttons on the front panel and to enter data using the software
keyboard and TouchScreen, you need to install the software keyboard driver from the
supplied disk. Installation is performed as follows:
Caution
For Windows NT version 4.0, do not install the driver unless Service
Pack 5 or higher has been installed because there may be operating
problems with earlier versions.
1. Switch on the PC and insert the Drivers floppy after the boot.
2. Click Start => Run => Browse to run the following program from the supplied floppy
disk
Soft-Keyboard_Vxx.exe
3. Follow the on-screen instructions, install the driver, specify the language and confirm
that you want to restart the computer.
7-4
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Regional Settings
You can subsequently adapt the key assignment of your virtual keyboard to the standard
layouts of other countries. The settings are stored in an INI file. To change the settings,
you will need to modify the file in a text editor such as NotePad. This can be done as
follows:
1. Start the text editor and open the SOFTKEY.INI file from the following directory:
C:\Program Files\ADS-TEC\SOFT-KEYBOARD
2. The available keyboard layouts and relevant parameters are listed in the initial section
under Long version code.
3. In the program section under [Common] in the Long version parameter, replace the
code entered after the equals sign with the desired code and save the file as a text file
with the same name.
4. Open the software keyboard and press the Ctrl, Alt and F11 buttons one after the
other. To confirm, click OK. The settings are then immediately applied.
Note: You can make further alterations to the default settings of the software keyboard.
Information on altering the settings can be found in the README file on the floppy
disk.
Read/Write CD-ROM Utilities
Installation and application instructions for copying files to a write-able CD are provided
with the supplied CD Writer Utilities.
GFK-2023C
Chapter 7 Driver Installation
7-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Chapter
8
Monitor System
IC5002/BC5002
TFT LC-Display
IC5005/BC5005
IC5008/BC5008
Display:
Diagonal:
307.4 mm (12.1")
SVGA (800 x 600)
383.5 mm (15.1")
XGA (1024 x 768)
459.7 mm (18.1")
Resolution (Pixel):
VGA controller:
SXGA (1280 x 1024)
(AGP)
(AGP)
(AGP)
2MB SDRAM
2MB SDRAM
4MB SDRAM
Colors:
256K
64K
64K
Brightness:
300 cd/m² (downward
adjustable)
400 cd/m² (downward
adjustable)
250 cd/m² (downward
adjustable)
Note: Back-lighting systems are consumable parts and are therefore not covered by the
warranty.
Industrial PC
IC5002/BC5002
IC5005/BC5005
IC5008/BC5008
Bus/Slot-CPU:
Processor:
RAM:
Passive PCI/ISA-Bus / All in One Slot-CPU with FCPGA-Socket
1.0 GHz or greater (Optional: PIII 1.4 GHz. FSB 133)
256 MB SDRAM (1 DIMM Slot)
Storage:
Hard disk min. 40 GB (3.5" UDMA)
3.5" Floppy disk
5.25" CD-ROM (Optional: CD-RW)
Ports:
a. COM1/2 (RS232 16550 compatible)
b. COM3 (RS232 16450 compatible)
c. LPT1
d. Keyboard PS/2
e. Mouse PS/2
f. Monitor
Two USB
Two 10/100BaseT (RJ45. 10/100Mbit full duplex)
Slots:
Two shared ISA/PCI
Two shared ISA/PCI
one PCI
Two shared ISA/PCI
one PCI
Power supply:
100—240 VAC, 100 watt, 50 – 60 Hz, Auto sense
Power
consumption:
48 watt (typical)
60 watt max.
54 watt (typical.)
62 watt max.
67 watt (typical.)
75 watt max.
GFK-2023C
8-1
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Expansion Cards
The maximum power consumption of additional expansion cards should not exceed 20
watts to avoid overheating.
The IC5005/BC5005 and IC5008/BC5008 models support full length cards size (339 mm).
The IC5002/BC5002 models support up to 290 mm cards size (3/4 ISA size).
Dimensions
IC5002/BC5002
IC5005/BC5005
IC5008/BC5008
Dimensions
(W x H x D):
330 x 268 x 183 mm
390 x 312 x 156 mm
442 x 371 x 160 mm
Mounting depth: 177 mm +
50 mm for cooling top
150 mm +
50 mm for cooling top
and bottom
154 mm +
50 mm for cooling top
and bottom
and bottom
30 mm for cooling on
sides
30 mm for cooling on
sides
30 mm for cooling on
sides
Weight:
6.9 Kg
8.3 Kg
10.7 Kg
Environmental Specifications
Temperature
Operating: 0—40°C
Storage: -20—60°C
Humidity
Shock:
Operating : 10—85% Non condensing
Storage: 10—85% Non condensing
Operating 15G equivalent, 11ms, 3 axis pos. and neg.
Non-operating 30G Reference IEC 68-2-27.
Vibration:
Operating: 1G, 5 to 9 Hz; 1.0g 9 to 150 Hz.
Non-operating: 2.5G, Reference IEC 68-2.
Agency Approvals
UL 1604 Class 1 Div 2
CE
Enclosure Protection
Noise Immunity
NEMA 4 (IP 65)
Electrostatic Discharge ESD EN 61000-4-2
Radiated Electromagnetic RF Fields EN 61000-4-3, ENV 50204
Fast transients BURST EN 61000-4-4
(acc. To EN 50082-2)
Conducted Electromagnetic RF-Fields EN 61000-4-6, ENV 50141
Emission
RF voltage EN 55011, EN 55022
RF fields EN 55011, EN 55022
(acc. To EN50081-2)
Standards
■
■
The IC500x product models meet the test requirements for the CE mark under
European test standards EN 55022 and EN 50082-2
The IC500x meets the test requirements of DIN EN 60950 (VDE0805. IEC950)
"Safety of information processing equipment "
8-2
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Port Configurations
Port
IRQ
Addresses
COM1
4
3
3F8h
2F8h
3E8h
2E8h
378h
COM2
COM3
5
COM4 (Touch)
LPT
10
7
Pin Assignments
Keyboard/Mouse (6-pin mini-DIN PS/2 socket)
Pin Number
Signal name
1
2
3
4
5
6
Data
NC
GND
+5V
Clock
NC
COM1/2/3 Serial Port (9 pin socket)
Pin-Number
Signal name
1
2
3
4
5
6
7
8
9
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
GFK-2023C
Chapter 8 Technical Data
8-3
Download from Www.Somanuals.com. All Manuals Search And Download.
8
LPT1 Parallel Port (25-pin D-Sub socket)
Pin-Number
Signal name
STROBE
Pin-Number
Signal name
1
14
15
16
17
18
19
20
21
22
23
24
25
-Auto Form Feed
-ERROR
-Initialize
-Printer Select In
GND
2
Data 0
3
Data 1
4
Data 2
5
Data 3
6
Data 4
GND
7
Data 5
GND
8
Data 6
GND
9
Data 7
GND
10
11
12
13
-ACK
GND
Busy
GND
Paper Empty
Print select
GND
CRT Analog Monitor Connector (15-pin HD-Sub socket)
Pin-Number
Signal name
Red
Pin-Number
Signal name
1
2
3
4
5
6
7
8
9
NC
Green
Blue
10
11
12
13
14
15
Sync-GND
NC
NC
DDC-Data
H-Sync
V-Sync
DDC-Clock
Sync-GND
AGND
AGND
AGND
Power Input (cable socket)
The power supply input to the industrial computer uses a standard IEC cable, which is
provided with the unit.
Pin
Signal
Outside
Center
Outside
100—240 VAC
ground
100—240 VAC
8-4
Intelligence Panel PC User’s Manual – August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
8
BIOS Settings
Unit Troubleshooting
For current troubleshooting and frequently asked questions, go to the GE Fanuc web site
Touchscreen Troubleshooting
The ACCU.PDF file in the \Docs\Manuals directory on the “Drivers” CD supplied for the
Touchscreen contains a user manual in Adobe Acrobat format. You will need Acrobat
Reader installed on your system to be able to view the manual (Acrobat Reader is
included on the CD).
The “Troubleshooting” sections in the manual tell you how to check the drivers in the
event of a malfunction of the Touchscreen.
GFK-2023C
Chapter 8 Technical Data
8-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
G
A
Graphics driver, 7-2
Air flow, 3-1
Application software
installing, 5-4
Auto logon, 5-2
H
Hard disk, 6-4
Hardware monitoring, 6-3
Hazardous locations installation, 3-6
B
BIOS settings, 8-5
I
Bundled solutions, 1-2
I/O Port Range Table
for legacy expansion cards, 4-4
Image recovery, 5-5
Industrial PC
C
Calibration
touchscreen, 5-4
technical data, 8-1
CD-ROM drive, 6-4
CIMPLICITY Machine Edition, 1-2
Control drawing CD-E219479
nonincendive field wiring, 3-7
Control keys, 6-1
Installation, 3-2
application software, 5-4
cards, 4-2
graphics driver, 7-2
legacy cards, 4-3
modules, 4-1
network adapter driver, 7-1
power cable, 3-6
softkeyboard, 6-2
D
site, 2-1
Slot cover plates, 4-2
Softkeyboard driver, 7-4
touchscreen driver, 7-3
UDMA driver, 7-4
Damage
inappropriate use, 2-2
transportation, 2-2
Dimensions, 8-2
Drivers
Installing application software, 5-4
Intelligence Panel
accessories, 1-5
graphics, 7-2
network adapter, 7-1
softkeyboard, 7-4
touchscreen, 7-3
UDMA, 7-4
installation, 3-1
key features, 1-1
ports, 6-5
shutting down, 5-4
standard features, 1-4
troubleshooting, 8-5
IRQs, for legacy cards, 4-3
E
Electrostatic discharges, avoiding, 4-1
Environmental specifications, 8-2
Expansion cards
K
installation, 4-2
technical data, 8-2
External keyboard, 6-2
External monitor, 6-7
Keyboard
softkeyboard, 6-2
L
F
LEDs
hardware monitoring, 6-3
PWR, 6-3
Features
overview, 1-1
standard, 1-4
Field image recovery disk, 5-5
Field wiring
Legacy ISA cards, 4-3
Login recommendation, 5-4
nonincendive, 3-7
Floppy disk drive, 6-4
GFK-2023C
Index-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
pin assignments, 8-3
port configurations, 8-3
standards, 8-2
M
Machine Edition, 1-2
Modules
Touchscreen, 6-3
calibration, 5-4
installation, 4-1
Monitor system
technical data, 8-1
Mouse, 6-4
driver, 7-3
troubleshooting, 8-5
Troubleshooting
Intelligence Panel, 8-5
touchscreen, 8-5
N
Network adapter driver, 7-1
Networking, 6-6
U
Nonincendive field wiring, 3-7
UDMA driver, 7-4
USB port connections
Nonincendive field wiring, 3-7
O
Operating system
recovery, 5-5
W
Warranty and repairs, 2-2
Windows 2000 systems
setting up, 5-3
P
Windows NT systems
setting up, 5-2
Pin assignments, 8-3
Port configurations, 8-3
Ports, 6-5
Power cable installation, 3-6
Power supply, 6-7
R
Read/write CD-ROM utilities, 7-5
Recovery, image, 5-5
Repairs, 2-2
Return authorization, 2-2
S
Setting up Windows 2000 systems, 5-3
Setting up Windows NT systems, 5-2
Shutting down the computer, 5-4
Slot cover plates, 4-2
Softkeyboard, 6-2
driver, 7-4
Standards, 8-2
Support, 1-4
T
Technical data
dimensions, 8-2
environmental specifications, 8-2
expansion cards, 8-2
Industrial PC, 8-1
monitor system, 8-1
Index-2
Intelligence Panel PC User's Manual–August 2003
GFK-2023C
Download from Www.Somanuals.com. All Manuals Search And Download.
|