PB3-POS-RP ProBridge
User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3
TABLE OF CONTENTS
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
4
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Before You Begin
Read these instructions before installing or operating this
product.
Note: This installation should be made by a qualified service person and should
conform to local codes.
This manual provides installation and operation information. To
use this document, you must have the following minimum
qualifications:
• A basic knowledge of CCTV systems and components
• A basic knowledge of electrical wiring and low-voltage
electrical hookups
Use this product only for the purpose for which it was designed.
Customer Support
For assistance in installing, operating, maintaining, and
troubleshooting this product, refer to this document and any
other documentation provided. If you still have questions, contact
Technical Support:
GE Security
Call: 888-437-3287
Note: You should be at the equipment, ready with details before calling Technical
Support.
Conventions Used in this Manual
Boldface or button icons highlight command entries. The
following WARNING, CAUTION, and Note statements identify
potential hazards:
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
6
* WARNING:
Improper use of this equipment can cause severe bodily
injury or equipment damage.
** CAUTION:
Improper use of this equipment can cause equipment
damage.
Note: Notes contain important information about a product or procedure.
* This symbol indicates electrical warnings and cautions.
** This symbol indicates general warnings and cautions.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Introduction
This manual provides all the information necessary to properly
install this product.
** CAUTION:
Your system’s layout, camera assignment, PB3
termination, and serial device model should all be selected
before starting the installation.
PB3-POS-RP Overview
The GE PB3-POS-RP (PB3) is a specific model of ProBridge
that interfaces the DVMRe family of digital video
multiplexer/recorders to retail point-of-sale (POS) devices often
identified as electronic cash registers (ECRs) and some ATM’s.
One PB3 is required per device. Where multiple devices are
connected to a single DVMRe unit, the individual PB3’s are
interconnected through its built-in RS485 network.
A list of the supported serial devices associated with the devices
can be found in the DIP switch settings section on page 24.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
8
Compatibility
The PB3 is compatible with the following GE DVMRe products:
DVMRe Type
DVMRe-CD/CS
DVMRe-eZ
Software Version
PPC Version
V 3.07 (and above) V 3.07 (and above)
V 3.20 (and above) V 3.14 (and above)
DVMRe-CT and
DVMRe-CT II
V 4.0 (and above)
N/A
DVMRe-eZT
(Triplex)
V 4.03 (and above) N/A
V 4.06 (and above) N/A
StoreSafe and
StoreSafe Pro II
To verify the software version in your DVMRe, note the display
which identifies the version when the unit boots-up or you can
click the About box in the Main Menu.
Additional Equipment
The installer will need to provide suitable length RS485 cable
terminated with RJ-45 connectors on installations requiring
multiple PB3 units that are interconnected via the unit’s built-in
RS485 network.
Disclaimer
The GE ProBridge components identified within this document
provide means of capturing transaction text/data for use by the
DVMRe family of digital video recording/transmission products.
The ProBridge components translate the data into a usable
format by the DVMRe and permits associating transaction data
Download from Www.Somanuals.com. All Manuals Search And Download.
9
with specific cameras. GE assumes no responsibility for the
amount and type of information available, the operation, non-
operation or erroneous operation of the customer provided
equipment that interfaces with the ProBridge.
PB3 System Components
You should find the following PB3 system components when the
product is unboxed.
Figure 1-1. PB3-POS-RP Box Contents.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
10
PB3-POS-RP ProBridge includes:
• (1) PB3-POS-RP ProBridge unit.
• (1) P/N 4310-0034B: RJ45 to RJ45 cable. Connects the
PB3 to RS485 Network. This cable is 6’ in length.
• (1) P/N 4310-0068A: serial device Interconnect Cable.
This cable is 14” in length.
• (1) P/N 4310-0047B: RJ45 to DB9F cable. Connects the
PB3 to the DVMRe. This cable is 6’ in length.
• (1) P/N 4310-0069A: serial device to PB3 Cable. This
cable is 6’ in length.
• (1) P/N 0900-0176: Triport Cable. This cable is 6’ in
length.
• (1) P/N 4010-0007: 12VDC 120VAC Power Supply or (1)
P/N 4010-0008: 12VDC 220VAC Power Supply.
• (1) P/N 0150-0231C: PB3-POS-RP User Manual.
Installation Environment
Power: Ensure that the installation site’s AC power is stable
and within the rated voltage of the external power supply. If the
site’s AC power is likely to have spikes or dips, use power line
conditioning or an Uninterruptible Power Supply.
Temperature: Observe the unit’s ambient temperature
specifications when choosing a location for the unit. Extremes of
heat or cold beyond the specified operating temperature limits
may cause the unit to fail. Do not install this unit on top of other
hot equipment.
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Moisture: Do not expose the unit to rain or moisture. Moisture
can damage internal components. Do not install this unit near
sources of water.
RS232 Limitations: Cable length between the POS device and
the PB3 is limited to 50’. Cable length between the PB3 unit and
the DVMRe is also limited to 50’. If the supplied cables are
replaced by custom made cables to address distances between
components, ensure the cable is manufactured to ANSI
standards for RS232 communication.
RS485 Limitations: If multiple PB3 units are connected to a
single DVMRe unit, the distance between the first and last PB3
unit is limited to 3,000 feet (RS485 communication standards).
Power
The PB3 is furnished with a power supply (110 or 240 VAC). Do
not use any other power supply with this product. The
manufacturer accepts no responsibility for damage caused by
the use of any other power supply.
Make sure installation is complete and all connections are made
before applying power to the unit.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
12
4310-0007 120VAC Power Supply
Power Supply Input
Voltage: 120 VAC
Tolerance: ±10%
Frequency: 60 Hz
Power Supply Output
Voltage: 12 VDC
Current: 110 mA
Power: 1.3 Watts
Connector: 2.1mm female barrel. Center Positive
4310-0008 220VAC Power Supply
Power Supply Input
Voltage: 220 Volt AC
Tolerance: ±10%
Frequency: 50 Hz
Power Supply Output
Voltage: 12 Volt DC
Current: 110mA
Power: 1.3 Watts
Connector: 2.1mm female barrel. Center Positive
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
14
Typical System Layout
Monitor
RS232/2
Port
DVMRe Triplex
4310-0034B
RJ45 to RJ45
Cable
Port 1
CBR-PB3-RP
Port 0
ProBridge
S485 Cable
lied by Installer)
*
Port 2
4310-0069A
Printer to PB3
Cable
Camera
4320-0068A
Receipt Printer
Cable
Electronic Cash Register
Receipt Printer
2nd
CBR-PB3-RP
ProBridge
*
4310-0069A
Printer to PB3
Camera
Cable
4320-0068A
Receipt Printer
Cable
Electronic Cash Register
Receipt Printer
Power Connections not show for clarity.
*
Figure 2-2. Typical System Layout.
** IMPORTANT:
Your system’s layout, camera assignment, PB3
termination, and serial device model should all be selected
before starting the installation.
Download from Www.Somanuals.com. All Manuals Search And Download.
15
Required Dip Switch Information
SW1
Dipswitch 1-4 Special Functions (See Section
3)
Dipswitch 5-8 Camera Assignment*
Dipswitch 1 Reserved
SW2
Dipswitch 2-4 Baud Rate
Dipswitch 5-8 Protocol
SW3
SW4
Dipswitch 1-8 serial device Device Select*
Dipswitch 3
ProBridge Termination*
*These settings should be set before beginning the installation.
Default (Factory) Dipswitch Settings
SW1
Up
SW2
Down
SW3
Down
SW4
Up
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Up
Up
Up
Up
Up
Up
Up
Down
Down
Down
Down
Down
Down
Down
Down
Down
Down
Down
Down
Down
Down
Up
Up
Up
Up
Up
Down
Up
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
16
Switch Settings as shown above are:
•
•
•
Camera Number 1 (SW1 5-8)
Generic Printer (SW3 1-8)
PB3 Termination OFF (SW4 3)
Detailed Installation Steps
Note: Modify the DVMRe’s default baud rate of 19200 to 57600.
1) At the minimum set or verify the DIP Switch settings for the
Camera Number, PB3 Termination, and the type of serial
device.
2) Disconnect the existing serial device cable from the Printer
and install the ECR Interconnect Cable (multiple DB25
connectors) to the serial device as shown on page 14.
Note: If the existing connection is using a DB9 to DB9 connection, then
use the supplied Triport cable in place of the ECR Interconnect cable.
See the Triport cable specification on page 45.
3) Reconnect the serial device Cable to one of the DB25F
connectors on the ECR Interconnect Cable as shown
on page 14.
4) Connect the PB3 Interface Cable (DB25M to DB9F) to the
remaining DB25F connector on the ECR Interconnect
Cable as shown on page 14. Connect the other end
(DB9F) to the DB9M connector on the PB3 unit (Port 2).
5) Connect the PB3 Power Supply to the unit, but do not plug
in the power.
Note: If only one (1) PB3 unit (one cash register) is to be connected, skip
to Step 9 below.
Download from Www.Somanuals.com. All Manuals Search And Download.
17
6) If more than one cash register interface is to be installed
repeat steps 1-4 above for each additional cash register.
7) Connect each PB3 unit together by using an RS485 cable
with RJ-45 connectors on each end. Connect to either
receptacle on Port 0 to interconnect the PB3 units using
an “in” and “out” method. (For details on the RS485 cable,
review the cable specifications).
Note: The installer shall provide this cable.
8) Confirm that each PB3 has the proper termination setting.
9) Connect the PB3 closest to the DVMRe using the supplied
cable from Port 1 (RJ45 outer receptacle) of the PB3 to
the RS232/2 port on the DVMRe unit.
Note: Modify the DVMRe’s default baud rate of 19200 to 57600.
10) Supply power to the PB3.
Verify Operation
To verify proper operation process several transactions at
the Cash Register.
To verify proper operation with a DVMRe-CT, eZT, or
StoreSafe unit:
Select full-screen on the Main Monitor (A) the camera associated
with a PB3 unit. Press the camera button until the text box
window appears in the display.
The text box will display any transaction data as it is passed to
the PB3 unit from the POS device. Be aware that some POS
devices only send transaction data until the end of the
transaction (when the receipt is printed).
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
18
If the unit fails to display transaction text, please go to the
troubleshooting section of this manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
19
Dip Switch Settings
This chapter deals in detail with the Dip Switch Settings. The
PB3 must be re-initialized before any changes to the switch
settings will be recognized.
SW1 Settings
SW1 –Switches 1-4
The first four switch positions on SW1 are programmed to
provide special functions on the PB3 for display and
troubleshooting. Under normal installations these settings do not
need to be changed from the defaults.
Switch Function
Display Memory
Demo Mode
1
D
D
D
D
2
D
D
D
U
3
U
U
D
D
4
U
D
D
D
Reset (Clear Memory)
Auto Line Feed
Display Mode
This setting displays all internal memory settings through Port 1
on the text box window of the selected camera on a DVMRe
Triplex. This allows you to quickly check what settings are in
your unit.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
20
Demo Mode (Simulated Message)
This setting permits the PB3 to send a simulated POS
transaction message to the DVMRe/Triplex. This is useful for
troubleshooting or for demonstrating PB3 functionality without
having a POS device connected. As a troubleshooting tool, this
element allows you to verify that the PB3 is able to send
messages and have the DVMRe correctly capture data coming
from the PB3. In this mode, if text can be received and
displayed, yet when attempting to process ECR data fails, then
some other problem exists with respect to the ECR connection
(cabling) or interface setup.
Reset (Clear Memory)
This is primarily a troubleshooting tool that allows the user to
clear the non-volatile memory of all settings. This will restore all
factory defaults as a first step to reconfiguring the unit.
Auto Line Feed
This option has been added to allow the insertion of Auto Line
Feeds when a new line character is detected in Generic mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
21
SW1 - Switches 5-8
Dipswitches 5 thru 8 on SW1 assigns transaction text for that
cash register’s PB3 unit to a specific camera on the DVMRe.
Camera Number
5
6
7
8
1
2
U
U
U
U
U
U
U
U
D
D
D
D
D
D
D
D
U
U
U
U
D
D
D
D
U
U
U
U
D
D
D
D
U
U
D
D
U
U
D
D
U
U
D
D
U
U
D
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
22
SW2 Settings
SW2 - Switch 1
Switch 1 on SW2 is reserved for Technical Support personnel.
Do not use.
SW2 - Switches 2-4
Switches 2-4 on SW2 are used to modify the baud rate on Port 2
of the PB3 should the POS device you are using require it.
SW2
Baud Rate Port 2
1200
2
3
4
U
U
U
U
D
D
D
U
U
D
D
U
U
D
U
D
U
D
U
D
U
2400
4800
9600
14.4k
19.2k
38.4k
Download from Www.Somanuals.com. All Manuals Search And Download.
23
SW2 - Switches 5-8
Switches 5-8 on SW2 are used to modify the communication
transfer protocol on Port 2 of the PB3 should the POS device
you are using require it. The protocol listed here consists of 3
user definable settings: The Start Bit, The Stop Bit, and Parity.
These can be expressed as follows:
•
•
•
Stop Bit: 7 or 8-bit ASCII
Stop Bit: 1 or 2-Stop bits
Parity: Odd, Even, or None
In the following table 8,1,E would translate to 8-start bits, 1-stop
bit, and Even parity.
SW2
Protocol
7,1,N
7,1,O
7,1,E
8,1,N
8,1,O
8,1,E
7,2,N
7,2,O
7,2,E
8,2,N
8,2,O
8,2,E
5
6
7
8
U
U
U
U
U
U
U
U
D
D
D
D
U
U
U
U
D
D
D
D
U
U
U
U
U
U
D
D
U
U
D
D
U
U
D
D
U
D
U
D
U
D
U
D
U
D
U
D
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
24
SW3 Settings
SW3 - Switches 1-8
Switches 1 thru 8 on SW3 define the serial device used for the
interface. The selection predetermines the Baud Rate and
Protocol for the target serial device.
Baud Rate and Protocol can be manually overridden using the
dipswitches for these elements.
Included Interfaces:
Serial data analyzer
Citizen POS printer
Pinnacle POS
Generic interface
Epson TM88
Radiant systems POS
Gilbarco PC/G-site journal
Epson TM-300A
Speedway POS
Wayne/Dresser
Axhiom printer 7158
VeriFone CR terminal
POS server output
Fujitsu pole display
XAPCOM
UTC model PD1100S-11345
NCR 7156
Teller line printer
Samsung 5215 pole
Positouch 1
Positouch 2
MICROS Eclipse POS
Challenger Printer Port
Axhiom printer A758
Download from Www.Somanuals.com. All Manuals Search And Download.
25
SW3
Printer
1
2
3
4
5
6
7
8
Serial DA
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
D
D
D
D
D
D
D
D
U
U
U
U
U
U
U
U
D
D
D
D
D
D
D
D
U
U
U
U
U
U
U
U
U
U
U
U
D
D
D
D
U
U
U
U
D
D
D
D
U
U
U
U
D
D
D
D
U
U
D
D
U
U
D
D
U
U
D
D
U
U
D
D
U
U
D
D
U
U
D
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
U
D
Generic
Citizen POS
Epson TM88
Pinnacle
Radiant
Speedway
Gilbarco
Wayne Dresser
Epson TM300A
Axhiom 7158
UTC
VeriFone
NCR 7156
POS server
Teller LP
Fujitsu Pole
Samsung 5215
XAPCOM
Positouch 1
Positouch 2
MICROS POS
Axiohm A758
Challenger
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
26
SW4 Settings
SW4 – Switches 1,2, 4-6
These switches are reserved for Technical Support personnel.
Do not use.
SW4 - Switch 3
Switch 3 on SW4 is used for signal termination for Port 0 on the
PB3. Termination is important whenever multiple PB3 units are
interconnected via the unit’s built-in RS485 network and the
length between the PB3’s is more than 2000 feet. The default
termination setting on the ProBridge 3 unit is with termination set
to OFF. Whenever there are more than two PB3’s, termination
on some of the PB3 units will change. The first PB3 and the last
PB3 on the RS485 network will have termination set to ON
(Down), all others between these two units will have their
termination set to OFF (Up).
SW4 - Switches 7-8
Switches 7 and 8 on SW4 controls the Network protocol of Port 1
on the PB3. In other words, Port 1 on the PB3 can communicate
as an RS232 or RS485 port depending on the needs on the
Network environment.
SW4
Netwwork Protocol
7
D
U
8
U
D
RS232
RS485
Download from Www.Somanuals.com. All Manuals Search And Download.
27
Troubleshooting
Problem
Probable Cause
Solution
*Unable to verify
capture of text.
1. No power.
1. Check power.
2. Incorrect cabling.
2. Check cables.
3. Incorrect switch
settings.
3. Verify settings
with Display
Memory mode
on page 18.
Garbled text.
Incorrect baud rate
Check baud rate for
POS device, set DIP
switches to match.
* Use Demo mode to verify that the PB3 is passing data to the DVMRe.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
28
Hyperterminal Setup
Manual configuration can also be completed using Windows
HyperTerminal in stead of the DIP switches. Manual
configuration should only be used if the “POS Device Selection”
does not conform to your specific device because baud rates or
protocols are slightly different than the default values for the
selected device.
Equipment Required
You will need the following equipment to program the PB3 using
HyperTerminal:
•
A PC or Laptop Computer with a COM port and
Windows 98/NT/200/XP installed and operational.
•
The supplied 4310-0047B PB3 to PC (DB9F to RJ45)
cable.
Setup
1. Remove power and disconnect the PB3 from the
DVMRe.
2. Plug the 4310-0047B cable into Port 1 of the
PB3 and a free COM port on your PC, typically
COM1.
3. Launch HyperTerminal, found in
Start/Programs/Accessories/Communications/
HyperTerminal.
Download from Www.Somanuals.com. All Manuals Search And Download.
29
Figure 5-1. Laptop connected to PB3 running HyperTerminal.
Open a new Connection (FILE>NEW):
Give the connection a
name and select an Icon.
Click OK.
Under “Connect Using” option select
“COM1”.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
30
The Com1 Properties menu will
appear. Select the following settings to
complete the setup:
Bits per Second = 57600
Data Bits = 8
Parity = None
Stop Bits = 1
Flow Control = None
Power up the PB3 unit by plugging in
the power supply. The following screen (or similar) will confirm
that you are in HyperTerminal programming mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
31
The configurable settings are:
•
•
•
•
•
•
Protocol
Baud Rate
Parity
# of Stop Bits
Character Set
POS Device Type
Once HyperTerminal mode is set up, press the “Enter” key twice.
The following menu will appear:
To make a menu selection, enter the number of the element and
press “Enter”.
For example:
Input the following
2
ENTER
(Port #2)
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
32
Main Menu Option 2 (Port #2)
Port #2 is an RS-232 port that connects the PB3 unit to the serial
device Interconnect Cable. The settings will vary based upon
the type of serial device in use.
Once you have selected this option, there will be multiple
selections available for each element. Entering the number for
the element will switch to the next option for that element.
Continue to enter the same element number until the desired
entry appears.
The menu options are presented similar to the following screen:
Note: To return to the Main Menu at any time press “1” and hit “Enter”.
Download from Www.Somanuals.com. All Manuals Search And Download.
33
Menu Selection 2 – Protocol Options
Asynchronous
•
Menu Selection 3 – Baud Rate
Baud Rate is only used if Protocol option selected is
Asynchronous.
•
•
•
•
•
•
•
1200
2400
4800
9600
14.4K
19.2K
38.4K
Menu Selection 4 – Parity
•
•
•
None
Odd
Even
Menu Selection 5 – Mode
The available selections are:
•
•
1-Stop (bit)
2-Stop (bit)
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
34
Menu Selection 6 – Code (Character)
The available selections are:
•
•
7-Bit ASCII
8-Bit ASCII
Menus Selection 7 – Device Type
Serial data analyzer
Citizen POS printer
Pinnacle POS
Generic interface
Epson TM88
Radiant systems POS
Gilbarco PC/G-site journal
Epson TM-300A
Speedway POS
Wayne/Dresser
Axhiom printer 7158
VeriFone CR terminal
POS server output
Fujitsu pole display
XAPCOM
UTC model PD1100s-11345
NCR 7156
Teller line printer
Samsung 5215 pole
Positouch 1
Positouch 2
MICROS Eclipse POS
Challenger Printer Port
Axhiom printer A758
IMPORTANT: You must BACKUP (Save) the program information via the
BACKUP option so that everytime the unit is powered up, the settings you
configured will be used. Go back to the Main Menu and select element #3
BACKUP and select the option to Save the settings.
Download from Www.Somanuals.com. All Manuals Search And Download.
35
Main Menu Option 3 (Text Setup)
The Text Setup menus allow the user to use some text filtering
options. These options allow the user to filter out excess data.
Select the Text Setup option from the Main Menu.
Once you have selected this option, there will be multiple
selections available for each element. Entering the number for
the element will switch to the next option for that element.
Continue to enter the same element number until the desired
entry appears.
The menu options are presented similar to the following screen:
Compare
Use this command to enable or disable Text filtering.
Toggle the Compare option by entering the number ‘2’ followed
by the Enter key.
2 > Enter
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
36
Bypass Count
The Bypass Count is the number of characters to bypass or
ignore excluding the characters in the Text String.
The Bypass Count can be entered when you enter the
sequence: 3 > Enter.
Enter Count: _
The range of the Bypass Count is 0 to 255. Entry will auto-
terminate after the 3rd number input. You may terminate input
by using the Enter key. The Backspace key may also be used
for correction.
Enter Count: 200 (auto-terminates)
Enter Count: 50 > Enter (manual termination)
Text String
The Text String option allows entering characters (up to 20) in a
string to be ignored or bypassed. When you enter the option ‘4’
followed by the Enter key, you will be prompted to enter a string.
Enter String: _
The maximum number of characters you can enter (including the
space character) is 20. The entered string of characters will be
converted to all UPPER CASE because the Text Filter is not
case sensitive.
Append Line Feed
This allows the Append Line Feed option to be enabled or
disabled. When the Append Line Feed option is enabled, each
time the PB3 receives a new line Character (Carriage Return or
Download from Www.Somanuals.com. All Manuals Search And Download.
37
Linefeed), the PB3 will output both a Carriage Return and a Line
Feed. If this option is disabled then, the PB3 will not append any
extra characters.
Toggle the Append Line Feed option by entering the number ‘5’
followed by the Enter key.
5 > Enter
Example of setting Text Setup Menu options:
1.
2.
Access the Text Setup Menu (Enter, Enter, 3, Enter).
Enable the String Compare (2, Enter) Compare:
Enabled.
3.
Set Bypass Count to 18 (3, Enter) and enter the number
18 followed by the Enter key.
4.
5.
Enter a text string (4, Enter) Thank you! > Enter.
Enable the Append option (5, Enter) Append Line Feed:
Enabled.
6.
Exit the menus (1, Enter) repeat 2 times.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
38
An example of the setup above is shown in the following
illustration.
Receipt
11/16/03
09:11:50
Data stored on HD
11/16/03
09:11:50
Coke................$1.49
Bottled Water.......$2.50
Potato Chips........$3.00
Coke................$1.49
Bottled Water.......$2.50
Potato Chips........$3.00
Subtotal...........$6.99
Tax................$0.31
Subtotal...........$6.99
Tax................$0.31
Total..............$7.20
Total..............$7.20
Text String
Thank you!
Please come again!
Bypass Count (18)
Figure 5-2. Example of Text Filtering and Bypass Count options.
Download from Www.Somanuals.com. All Manuals Search And Download.
39
Main Menu Option 4 (Alarm Setup)
Use this option to enable or disable alarm mode and to
customize the text to display for each alarm. Select option #4 to
display the following screen
To change the alarm mode select option #2 and press the enter
button. The alarm mode will toggle between enabled or disabled.
You can enter customized alarm text by selecting options 3
through 7 and entering your text. Your text string can be up to 15
characters. Make sure you save your changes before exiting
HyperTerminal.
Main Menu Option 4 (Backup)
Use the Backup menu (Main Menu Option 5), to save the
settings that you have modified.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
40
PB3 Specifications
Physical
Metal enclosure.
Housing
Dimensions
(W x L x H)
4.0 x 7.0 x 1.0” (100 x 175 x
25 mm)
4.8 oz (136 g)
Nominal Weight
Shipping Weight
1 lb (453 g) packaged, including
the external AC power supply and
manual.
Black.
Color
Environmental
Temperature
0 to 40 °C, operating.
90%, non-condensing.
Relative Humidity
Electrical
External AC power supply included.
AC Power
110 to 240 VAC + 10%
200 mA
Voltage Range:
Current:
DC jack, positive center.
12 VDC
DC Power
Power Supply Voltage:
Current:
110 mA
1.5 W
Power:
Note: All specifications are subject to change without notice. GE believes that all
specifications are correct, however no liability is assumed for omissions or errors.
Download from Www.Somanuals.com. All Manuals Search And Download.
41
Cable Specifications
ProBridge to Triplex (DVMRe-CT)
RJ45 Connector
RJ45 Connector
Part Number : 4310-0034B
Pin 8:
Pin 8:
Pin 7: Common
Pin 7: Common
Pin 6: A-
Pin 6: A-
Communication Type: RS232
Connector Type: RJ-45, RJ-45
Pin 5: Rcv
Pin 4: Tx
Pin 3: A+
Pin 2:
Pin 5: Rcv
Pin 4: Tx
Pin 3: A+
Pin 2:
Cable Required: 5 Foot RJ-45 to
RJ-45 Triplex RS232 Cable
(Supplied). Connects ProBridge
to DVMRe-CT.
Pin 1: Common
Pin 1: Common
RJ-45
Connector
to Triplex
RJ-45
Connector
to PB3
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
42
ProBridge to DVMRe (DVMRe-CD/S)
DB9F
RJ45 Connector
Part Number : 4310-0047B
Pin 9
Pin 8
Pin 8
Communication Type: RS232
Pin 7
Pin 7
Pin 6
Pin 6
Pin 5: Common
Pin 5: Common
Pin 4
Connector Type: RJ-45 ,DB9F
Pin 4
Pin 3: Rcv
Pin 2: Tx
Pin 1
Pin 3: Rcv
Pin 2: Tx
Pin 1
Cable Required: 6 Foot RJ-45 to
DB9F RS232 Cable (Supplied).
Connects ProBridge to DVMRe-
CD/CS.
RJ-45
Connector
to PB3
DB-9F
Connector
to Duplex
NOTE: This cable also used for
Programming ProBridge via Windows
HyperTerminal
Download from Www.Somanuals.com. All Manuals Search And Download.
43
ProBridge to ProBridge Cable
RJ45 Connector
RJ45 Connector
Part Number : Installer Provided
Pin 8: Brown
Pin 8: Brown
GND
Pin 7: Brown/White
Pin 6: Green
Pin 7: Brown/White
Pin 6: Green
RS485 -
Communication Type: RS-485
Connector Type: RJ45, RJ45
Pin 5: Blue/White
Pin 4: Blue
Pin 5: Blue/White
Pin 4: Blue
RS485 +
GND
Pin 3: Green/White
Pin 2: Orange
Pin 3: Green/White
Pin 2: Orange
Cable Required: RS-485
Interconnect Cable (up to 3,000’)).
Interconnects multiple PB3’s in a
RS485 network.
Pin 1: Orange/White
Pin 1: Orange/White
RJ-45
Connector
RJ-45
Connector
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
44
ProBridge to Printer Interconnect Cable
DB9F
DB25M
Part Number : 4310-0069A
Pin 25
Pin 24
Pin 23
Pin 22
Pin 21
Pin 20
Communication Type: RS232
Connector Type: DB25M, DB9F
Pin 19
Pin 18
Pin 17
Cable Required: 6 Foot DB25M to
DB9F RS232 Cable (Supplied).
Connects PB3 to the Printer
Interconnect Cable.
Pin 16
Pin 15
Pin 14
Pin 13
Pin 12
Pin 11
Pin 10
Pin 9
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
Pin 9
Pin 8
Pin 7
Pin 6
Pin 5: Tx
Pin 4
Pin 3: Rcv
Pin 2
Pin 1
DB-25M
Connector
DB-9F
Connector
Download from Www.Somanuals.com. All Manuals Search And Download.
45
ProBridge Interconnect Cable to serial device
DB25M
DB25F
DB25F
Part Number : 4310-0068A
Communication Type: RS232
Connector Type: DB25M, DB25F, DB25F
Cable Required: 6 Foot DB25M to DB25F to DB25F cable (Supplied).
Connects PB3 Interconnect cable to the serial device.
DB-25M
Connector
DB-25F
Connector
DB-25F
Connector
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
46
Triport Cable
The Triport cable is used for tapping serial RS-232 ports
available on most POS cash registers. The Tri-Port does not
interfere with any signals between the POS and the printer (if
there is an external printer connected).
For installation, do the following:
1. Remove the DB9 printer connector at the POS (if an
external printer is connected).
2. Install the Triport connector (printed circuit board) into
the vacated POS connector.
3. Connect the DB9 printer connector to the Triport.
4. Connect the Triport cable (gray cable w/DB-9S) to the
PB3.
NOTE1: If a printer was not attached to the POS, it may be necessary to
enable the serial port on the POS. Program the POS for a printer setting.
NOTE2: If the POS uses a DB-25 serial connector, use two “DB-25 to DB-9”
adaptors. These adaptors are readily available most electronic stores.
Hardware Handshake Jumpers JP1 and JP2
For a POS system with an external printer connected, remove
the JP1 and JP2 jumpers.
For a POS system without a printer, it may be necessary to
jumper one or both JP1/JP2.
•
•
JP1 shorts pins 7 and 8 (RTS/CTS)
JP2 shorts pins 4 and 6 (DTR/DSR)
Download from Www.Somanuals.com. All Manuals Search And Download.
47
Triport Cable Modifications
In some cases, it may become necessary to modify the wiring of
the Triport cable. It is recommended that only trained
technicians modify the Triport. Modifications are limited to only
the removal of the orange or blue wire. Removing both wires or
re-attaching these wires to other solder points may disrupt
communications between the POS device, printer, and/or the
PB3.
Ref: The orange wire carries signals from the transmit signal of
the cash register.
Ref: The blue wire carries signals from the transmit signal of the
printer.
Part Number : 0900-0176
Communication Type: RS232
Connector Type: DB9M, DB9F, DB9F
Cable Required: 6 Foot DB29F to
DB9F and DB9M RS232 Cable
(Supplied). Connects PB3 to the POS
device and printer.
Download from Www.Somanuals.com. All Manuals Search And Download.
PB3-POS-RP ProBridge
User Manual
48
Contacting technical support
For assistance installing, operating, maintaining, and
troubleshooting this product, refer to this document and any
other documentation provided. If you still have questions, you
may contact technical support during normal business hours
(Monday through Friday, excluding holidays, between 6 a.m. and
5 p.m. Pacific Time).
Table 1. Sales and support contact information
Sales
Technical support
Toll-free: 888.GESECURity (888.437.3287 in the US, including
Alaska and Hawaii; Puerto Rico; Canada).
Phone:
Outside the toll-free area: 503.885.5700.
E-mail
Fax
800.483.2495
541.752.9096 (24 hours/day)
Note:
Be ready at the equipment before calling for technical support.
Online publication library
Another great resource for assistance with your GE Security
products is our online publication library, available to all of our
customers on our website. To access our publication library, go
to our website at the following location:
In the Tools area at the top, click the Publication Library link.
After you register and log on, you may search through our online
library for the documentation you need.1
1
Many GE Security documents are provided as PDFs (portable document format).
To read these documents, you will need Adobe Acrobat Reader, which can be
Download from Www.Somanuals.com. All Manuals Search And Download.
|