Load Centers and Circuit Breakers
Section 1
Q-Line Circuit Breakers– Product Features and Benefits........1-2
PowerMark Gold Load Centers—
Product Features and Benefits ........................................................1-3
PowerMark Gold and Plus Load Centers—
Product Number Guides......................................................................1-4
Q-Line Plug-in Circuit Breakers............................................................1-5
Special Purpose Circuit Breakers........................................................1-6
PowerMark Gold and Plus Single-Phase Load Centers—
Main Lug Convertible to Main Breaker.........................................1-9
Main Breaker Factory Installed.....................................................1-12
PowerMark Plus™ Three-Phase Load Centers—
Main Circuit Breakers or Main Lugs Factory Installed .......1-14
PowerMark Gold Load Centers—Specialty Panels...................1-17
PowerMark Gold Meter Socket Load Centers ............................1-18
Field Installed Accessories...................................................................1-24
Wiring Diagrams......................................................................................1-30
Load Centers and Meter Socket Load Centers—
Knockouts................................................................................................1-37
BuyLog™ Catalog
Rev. 11/13
1-1
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
Section 1
PowerMark Gold Load Centers
Highest Quality and Convenience
Main breaker configura-
tion allows top or bottom
feed without modification
One-piece interior
removes and
reinstalls easily
PowerMark Gold load centers lower your costs by making installa-
tion faster and easier, increasing application flexibility and reduc-
ing inventory requirements. At the same time, they deliver obvious
and significant advances in design, function and quality.
—UL Listed (Panelboards No. 67)
—Suitable for Use as Service Entrance Equipment when installed
in accordance with National Electrical Code
—60°C/75°C Conductor Rating
Combination
slotted/Robertson
square-drive
speeds screw
wiring
Full-length neutrals
are easier to wire,2
reducing installation
time and cost
—Single phase, 40-225A, 2-42 circuits
—Main lug models field convertible to main breaker
—Main breaker 22kAIC standard - factory installed
—All load centers top or bottom feed
All holes rated
for 14-4 wire
—Indoor and outdoor rated enclosures
—Indoor fronts combination surface/flush
—Copper bus with tin plating standard
Minimum 100%
neutral
1
—Split neutrals extend the full length of the interior for ease of wiring
—Entire main lug line converts easily to main breaker
—Combination surface/flush front with spring-reinforced pan
—Combination slotted/Robertson square-drive screws on neutral,
ground, front and breaker lugs
terminations
100% rated
split neutral
on each side2
2
Sturdy copper bus
and galvanized box
increase durability
and reliability
—Front packed in inner carton for added protection
—Field installable feed-through lugs up to 200A
—Straight-through main wiring
—Main breaker is clearly marked and circuit numbers are stamped
on front
Tie bar may be
removed to split
neutral/ground
Accepts GE Q-Line branch
circuit breakers, including
GE’s exclusive 1/2" THQPs
—Isolated ground bar is available
—Compact box maintains optimum wire-bending space
A complete family of meter socket load centers — ring style
and ringless, wide and narrow, meter mains, farm panels and
more — deliver specialized solutions for special situations.
Packaging features comprehensive
selection and application data.
Fronts are packed in inner cartons
for added protection during shipment
and at the job site.
The PowerMark Gold
line includes a wide
range of outdoor as
well as indoor units.
GE’s residential load centers reach into
commercial applications as well, with riser
panels, auxiliary gutters, three-phase units
with standard 22kAIC ratings, and all the
accessories needed to complete the job.
Main lug load centers offer an economical
solution for subpanels and similar applications.
All main lug units 125A and above convert easily
to main breaker.
Accessories and Options
Safety accessories – convenient and easy to install
—Door lock and handle
—Equipment ground kits
—Sub-feed and feed-thru lugs
—Front filler plates
—Hardware kits
—Main breaker retainers
—Neutral kits
—THQLSURGE whole house surge protector
—Arc fault circuit interrupter breaker, 1- or 2-pole
—Ground fault circuit interrupter breaker, 5mA and 30mA
—Generator transfer panel – 30A or 60A, indoor or outdoor
—GE AC disconnects
—Universal raintight hubs
—Handle lock and ties
1
Three-phase PowerMark Plus load centers have aluminum bus with copper breaker
mounting stabs.
16 circuit and above.
2
BuyLog™ Catalog
1-3
Rev. 11/13
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
PowerMark Gold and Plus Load Centers
Product Number Guides
Product Number Guide for Load Centers
(Product number for illustrative purposes only)
T
M
42
4
20
C
CU
B
GE Identification
Insert for Specials
G or T = Factory installed ground bar
B = Bottom feed main breaker
FL = Factory installed feed-through lugs
D = Optional door for 6-8 circuit panel.
(Doors standard on all units 12
circuits or greater)
Type
M = Main breaker
L = Main lug
LM = Convertible
W = White Front
PL = Main lug (Thermoplastic)
Insert for PowerMark Gold
CU = Copper Bus
42 = Copper Bus Full 42 circuit panel
Maximum Number 1" Spaces
2, 4, 6…42
Enclosure Type
C = Combination surface/flush
F = Flush
S = Surface
R = Outdoor
Insert for 3-Phase 4-Wire
Load Centers
Bus Ampere Rating
40 = 40 Amps
70 = 70 Amps
10 = 100 Amps
12 = 125 Amps
15 = 150 Amps
20 = 200 Amps
22 = 225 Amps
30 = 300 Amps
40 = 400 Amps
60 = 600 Amps
Product Number Guide for Q-Line Plug-in Circuit Breakers
(Product number for illustrative purposes only)
T
H
QL
1
1*
15
GFT
GE Identification
Ground Fault/Arc Fault Circuit Interrupter
AF2 = 1- & 2-pole Combination Arc Fault
Circuit Interrupter
GFEP = 1- & 2-pole Ground Fault with
Equipment Protection Interrupter–30 mA
GFT = 1- & 2-pole Ground Fault
Interrupting Rating
H = 10kAlC
HH = 22kAlC
X = 65kAlC
with Self-Test Feature Interrupter - 5 mA
DF = 1-pole Dual Function GFCI/AFCI Ground Fault
& Combination Arc Fault Circuit Interrupter
Type
QL = 1" plug-in
QP = 1/2" plug-in
QB = 1" bolt-on
Ampere Rating
Voltage
1 = 120/240V
2 = 240V
Poles (1, 2, 3)
*Omit character for THQP breakers, which are all 120/240V.
BuyLog™ Catalog
Rev. 11/13
1-4
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Q-Line Plug-in Circuit Breakers
UL Listed (Molded Case Circuit Breakers No. 489)
Federal Government Specification Qualified (WC-375B)
60°C / 75°C Conductor Rating
Section 1
Quick Make, Quick Break
Box Type Terminals
THQP130
THQP230
THQL1120
Q-Line Plug-in Circuit Breakers Specifications
1
Wire Size AWG/kcmil
Breaker Type
Ampere Rating
Cu
Al
15-25
30-50
14-8
8-4
12-8
8-4
THQP
15-30
35-60
70-100
110-125
14-8
8-3
6-1/0
2-2/0
12-8
8-3
4-1/0
2-2/0
THQL
THHQL
TXQL
1
Solid or stranded for 14-10 AWG
THQL2140
THQL32015
Q-Line Plug-in Circuit Breakers
10,000AIC
Type THQL 1-inch Module
22,000AIC
Type THHQL 1-inch Module
65,000AIC
Type TXQL 1-inch Module
120/240 Vac
Type THQP 1/2-inch Module
120/240 Vac
120/240 Vac
120/240 Vac
240 Vac
120/240 Vac
240 Vac
Ampere
Rating
Product
Number
Product
Number
Product
Number
Product
Number
Product
Number
Product
Number
1
Single Pole
2
15
THQP115
THQP120
THQP125
THQP130
THQP135
THQP140
THQP145
THQP150
5 cartons of 20
THQL1115
THQL1120
THQL1125
THQL1130
THQL1135
THQL1140
THQL1145
THQL1150
5 cartons of 10
–
–
–
–
–
–
–
–
THHQL1115
THHQL1120
THHQL1125
THHQL1130
THHQL1135
THHQL1140
THHQL1145
THHQL1150
5 cartons of 10
–
–
–
–
–
–
–
–
TXQL1115
TXQL1120
TXQL1125
TXQL1130
–
–
–
–
2
20
25
30
35
40
45
50
Std. Pkg.
5 cartons of 10
3
Two-Pole : Incorporates Internal Common Trip Bar
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
15
20
THQP215
THQP220
THQL2115
THQL2120
THQL2125
THQL2130
THQL2135
THQL2140
THQL2145
THQL2150
THQL2160
THQL2170
THQL2180
THQL2190
THQL21100
THQL21110
THQL21125
5 cartons of 5
THQL22015
THQL22020
THQL22025
THQL22030
THQL22035
THQL22040
THQL22045
THQL22050
THQL22060
THQL22070
THQL22080
THQL22090
THQL22100
–
THHQL2115
THHQL2120
THHQL2125
THHQL2130
THHQL2135
THHQL2140
THHQL2145
THHQL2150
THHQL2160
THHQL2170
THHQL2180
THHQL2190
THHQL21100
THHQL21110
THHQL21125
5 cartons of 5
THHQL22015
THHQL22020
THHQL22025
THHQL22030
THHQL22035
THHQL22040
THHQL22045
THHQL22050
THHQL22060
THHQL22070
THHQL22080
THHQL22090
THHQL22100
–
TXQL2115
TXQL2120
TXQL2125
TXQL2130
–
–
–
–
–
–
–
–
–
–
–
25
THQP225
30
THQP230
35
THQP235
40
THQP240
45
THQP245
50
THQP250
60
–
70
–
80
–
90
–
100
110
125
Std. Pkg.
–
–
–
–
–
5 cartons of 10
5 cartons of 5
5 cartons of 5
5 cartons of 5
3
Three-Pole : Incorporates Internal Common Trip Bar
15
20
25
30
35
40
45
50
60
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
THQL32015
THQL32020
THQL32025
THQL32030
THQL32035
THQL32040
THQL32045
THQL32050
THQL32060
THQL32070
THQL32080
THQL32090
THQL32100
5 cartons of 3
–
–
–
–
–
–
–
–
–
–
–
–
–
THHQL32015
THHQL32020
THHQL32025
THHQL32030
THHQL32035
THHQL32040
THHQL32045
THHQL32050
THHQL32060
THHQL32070
THHQL32080
THHQL32090
THHQL32100
5 cartons of 3
TXQL32015
TXQL32020
TXQL32025
TXQL32030
–
–
–
–
–
–
–
–
70
80
90
100
Std. Pkg.
–
5 cartons of 3
1
UL Listed as HACR (heating, air conditioning and refrigeration).
References:
Accessories Pages
2
UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting
loads.
1-24 thru 1-29
Auxiliary Switches and Shunt Trips
BuyLog pages 6-40 thru 6-42
3
15-100 amp UL Listed as HACR (heating air conditioning and refrigeration).
Required for three-phase and High Leg Delta Systems only.
4
BuyLog™ Catalog
Rev. 11/13
1-5
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating
Box Type Terminals
Quick-Make, Quick-Break
Multi-pole Breakers Incorporate Internal Common Trip
Arc Fault2
UL Listed
Arc-Fault Circuit Interrupters No. 1699
1
1 Pole, 120/240 Volts ac
Ampere Rating
Product Number
10,000 AIC
15
20
THQL1115AF2
THQL1120AF2
22,000 AIC
Std. Pkg.
15
20
THHQL1115AF2
THHQL1120AF2
10 Cartons of 1
As of Jan. 1, 2008, 2005 NEC™ requires combination AFCI.
1
Combination AFCI compliant with 2008 NEC™ and later
2
For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See DET-719 for more
details on our Arc Fault products.
Arc Fault
Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker
UL Listed (Available December 2014)
1 Pole, 120 Volts ac
Ampere Rating
Product Number
10,000 AIC
15
20
THQL1115DF
THQL1120DF
22,000 AIC
Std. Pkg.
15
20
THHQL1115DF
THHQL1120DF
10 Cartons of 1
Ground Fault with Self-Test Feature
THQL1115DF
cULus
Ground Fault Circuit Interrupters UL943 ed5 (5 milliamperes)
1-Pole, 120 Volts ac
Product Number
2-Pole, 120/240 Volts ac
Product Number
Ampere Rating
10,000 AIC
15
20
25
30
40
50
THQL1115GFT
THQL1120GFT
THQL1125GFT
THQL1130GFT
–
THQL2115GFT
THQL2120GFT
THQL2125GFT
THQL2130GFT
THQL2140GFT3
THQL2150GFT3
–
22,000 AIC
15
20
25
30
THHQL1115GFT
THHQL1120GFT
THHQL1125GFT
THHQL1130GFT
–
–
–
–
3
UL & CSA
THQL2120GFT
PowerMark Gold Main Circuit Breakers for use with 150A-225A PowerMark Gold Load
Centers (Includes mounting base)
UL Listed.
Description
Ampere Rating
Product Number
Lug Size
100
125
150
175
200
225
THQMV100D
THQMV125D
THQMV150D
THQMV175D
THQMV200D
THQMV225D
Main Circuit Breaker Kits
22,000 AIC
1-300 (cu),
2/0-300
Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load
centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker
versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is
converted to main breaker.
THQMV100D with filler plates
BuyLog™ Catalog
Rev. 11/13
1-6
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
Section 1
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating
Box Type Terminals
Quick-Make, Quick-Break
Multi-pole Breakers Incorporate Internal Common Trip
PowerMark Gold Main Circuit Breaker Kit
For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Description
Product Number
1
TQMH000
Main Circuit Breaker Kit - Order appropriate THQL
10kAIC or THHQL 22kAIC breakers separately
1
Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to
convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load
centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
TQMH000
Ground Fault with Equipment Protection
cULus
Ground Fault Circuit Interrupters No. 943 30 milliampere ground fault trip level
1-Pole, 120 Volts ac
Product Number
2-Pole, 120/240 Volts ac
Product Number
Ampere Rating
10,000 AIC
Std. Pkg.
15
20
30
THQL1115GFEP
THQL1120GFEP
THQL1130GFEP
10 Cartons of 1
THQL2115GFEP
THQL2120GFEP
THQL2130GFEP
10 Cartons of 1
Switching Neutral
UL Listed. 10kAIC RMS symmetrical.
Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.
1-Pole Plus Switching Neutral
2-Pole Plus Switching Neutral
120/240 Volts ac
120/240 Volts ac
Ampere Rating
Product Number
Product Number
15
20
25
30
THQL21WY15
THQL21WY20
THQL21WY25
THQL21WY30
5 cartons of 5
THQL31WY15
THQL31WY20
THQL31WY25
THQL31WY30
5 cartons of 3
THQL21WY30
Std. Pkg.
"HID" Lighting
UL Listed as HID. HID breakers have been designed to handle the current and voltage
spikes that result when gaseous discharge lamps, including fluorescent and HID lamps,
are switched on and off.
1-Pole, 120/240 Volts ac
2-Pole, 120/240 Volts ac
Ampere Rating
Product Number
Product Number
10,000 AIC
22,000 AIC
2
15
20
30
THQL1115HID
THQL2115HID
THQL2120HID
THQL2130HID
2
THQL1120HID
THQL1130HID
THQL2120HID
2
15
20
30
THHQL1115HID
THHQL1120HID
THHQL1130HID
5 cartons of 10
THHQL2115HID
THHQL2120HID
THHQL2130HID
5 cartons of 5
2
Std. Pkg.
2
UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.
High Magnetic
UL Listed. 10kAIC RMS symmetrical
High short circuit setting suitable for circuits with inherent high-inrush load currents.
1-Pole, 120/240 Volts ac
Ampere Rating
Product Number
15
20
25
30
40
50
THQL1115HM
THQL1120HM
THQL1125HM
THQL1130HM
THQL1140HM
THQL1150HM
5 cartons of 10
THQL1140HM
Std. Pkg.
BuyLog™ Catalog
Rev. 11/13
1-7
Prices and data subject
to change without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating
Box Type Terminals
Quick-Make, Quick-Break
Multi-pole Breakers Incorporate Internal Common Trip
Molded Case Switches
UL Listed
Without overload or short circuit protection.
2-Pole
3-Pole
Ampere Rating
Product Number
Product Number
120/240 Volts ac
60
100
TQL21Y60
TQL21Y100
–
–
TQL21Y100
240 Volts ac
Std. Pkg.
60
100
TQL22Y60
TQL22Y100
5 cartons of 5
TQL32Y60
TQL32Y100
5 cartons of 3
Interlocking Circuit Breakers for use in PowerMark Gold Generator Panels
Two breakers required for interlocking.
Poles
Ampere Rating
Product Number
2
2
30
60
THQL2130GEN
THQL2160GEN
TQ1120
TQ Circuit Breakers
3/4" UL Classified Circuit Breakers for use in *Square D **QO Load Centers.
10 kAIC RMS symmetrical
1-Pole
Product Number
2-Pole
Product Number
Ampere Rating
15
20
30
40
50
60
TQ1115
TQ1120
TQ1130
TQ1140
TQ1150
–
TQ2115
TQ2120
TQ2130
TQ2140
TQ2150
TQ2160
Std. Pkg.
1 carton of 10
1 carton of 5
TQ2120
THQL 120/240 Vac, with Factory Installed Shunt1
# of
Poles
Ampere
Rating
120/240 Vac
2
Wire Range
Interrupting Rating
Product Number
1
1
1
1
1
1
1
1
15
20
30
35
40
45
50
(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
10kA
10kA
10kA
10kA
10kA
10kA
10kA
THQL1115ST1
THQL1120ST1
THQL1130ST1
THQL1135ST1
THQL1140ST1
THQL1145ST1
THQL1150ST1
Shunt trip requires one additional pole of space.
THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt1
THQL1130ST1
# of
Ampere
Rating
240 Vac
2
Poles
Wire Range
Interrupting Rating
Product Number
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
2
15
20
30
35
40
45
50
60
70
80
90
100
20
30
40
50
60
70
80
90
100
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
THQL2115ST1
THQL2120ST1
THQL2130ST1
THQL2135ST1
THQL2140ST1
THQL2145ST1
THQL2150ST1
THQL2160ST1
THQL2170ST1
THQL2180ST1
THQL2190ST1
THQL21100ST1
THQL32020ST1
THQL32030ST1
THQL32040ST1
THQL32050ST1
THQL32060ST1
THQL32070ST1
THQL32080ST1
THQL32090ST1
THQL32100ST1
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
THQL2120ST1
Solid or stranded for 14-10 AWG.
THQL32020ST1
*Square D is a registered trademark of SNA Holdings, Inc. **QO is a registered trademark of the Square D Company.
BuyLog™ Catalog
Rev. 11/13
1-8
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac
Main Lug
Indoor NEMA 1
Main Lugs Convertible to Main Breaker
Product Features
—UL Listed (Panelboards No. 67)
—60°/75°C Conductor Rating
—Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
—22kAIC RMS symmetrical, Except Where Noted
—6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down.
—For a listing of CSA Listed load centers, visit geindustrial.com.
TLM2020CCU
TPL412R
Main Lugs Factory Installed (TLM units convertible to main breaker),
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
1 Pole,
1/2”
2 Pole,
1/2”
Total
Main Wire Size
(AWG/kcmil)
Ampere
1-pole
Front
Type
Box
Equipment
Ground Kit
Product
Number
1
Rating Spaces
Spaces
Spaces
Spaces
Spaces
Feed Type
Number
Cu-Al
1,8
TL240SCU
40
2
1
1
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
4
6
6
4
1
1
3
3
3
3
4
4
4
4
4
4
8
8
8
8
8
8
8
8
4
Surface
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
1A
1A
2A
2A
2
14-4
6-3
TGK4 (order separately)
TGK4 (order separately)
TGL1 (order separately)
TGL1 installed
1,8
TL270SCU
70
2
4
4
Surface
1,2,8
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
4
8
8
Combination
Flush/Surface
Combination
Flush/Surface
Thermoplastic
1-2/0
1-2/0
1-2/0
1-2/0
6-1
TL412C
1,2,3,8
1,2,3,8
1,2,3,8
4
8
8
TL412CT
TPL412C
4
8
8
TGL1 (order separately)
TGL1 installed
4
8
8
Thermoplastic
Flush
2
TPL412CT
4,8
6
12
12
12
12
12
12
16
16
16
16
16
16
20
20
12
12
12
12
12
12
16
16
16
16
16
16
24
24
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
18
18
TGL2 (order separately)
TGL2 (order separately)
TGL2 installed
TLM612FCU
4,8
TLM612FCUD
6
Flush
6-1
4,8
4,8
4,8
6
Flush
6-1
TLM612FCUDG
4,8
6
Surface
Surface
Surface
Flush
6-1
TGL2 (order separately)
TGL2 (order separately)
TGL2 installed
TLM612SCU
4,8
6
6-1
TLM612SCUD
6
6-1
TLM612SCUDG
4,8
8
6-1
TGL2 (order separately)
TGL2 (order separately)
TGL2 (order separately)
TGL2 (order separately)
TGL2 (order separately)
TGL2 installed
TLM812FCU
4,8
8
Flush
6-1
TLM812FCUD
8
Flush
6-1
TLM812FCUDG
4,8
8
Surface
Surface
Surface
6-1
TLM812SCU
4,8
8
6-1
TLM812SCUD
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
4,8
8
6-1
TLM812SCUDG
10
7,8
TLM1212CCU
14
14
Combination
Flush/Surface
White Combo
Flush/Surface
6-2/0
6-2/0
Included
10
7,8,9
TLM1212CCUW
Included
This table continued on next page
BuyLog™ Catalog
Rev. 11/13
1-9
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac
Main Lug
Indoor NEMA 1
Main Lugs Convertible to Main Breaker
Main Lugs Factory Installed (TLM units convertible to main breaker),
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
1 Pole,
1/2”
2 Pole,
1/2”
Total
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
1-pole
Spaces
Front
Type
Box
Equipment
Ground Kit
Product
Number
Rating Spaces
Spaces
Spaces
Spaces
Feed Type Number
5
125
125
125
125
125
200
200
200
200
200
200
200
200
200
200
200
200
200
225
16
16
24
24
24
16
16
16
20
20
20
24
32
32
32
40
40
42
42
8
16
16
0
6
24
24
24
24
24
32
32
32
40
40
40
42
42
40
40
40
40
42
42
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
White Combo
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
White Combo
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
White Combo
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
White Combo
Flush/Surface
Combination
Flush/Surface
White Combo
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
4
6-2/0
6-2/0
6-2/0
6-2/0
6-2/0
6-250
6-250
6-250
6-250
6-250
6-250
TGK12 and TGK24
(order separately)
TGK12 and TLK20
installed
TGK24 and TGK32
(order separately)
TGK24 and TGK32
(order separately)
TGK24 and TLK20
installed
TGK32
(order separately)
TGK32
(order separately)
TGK32
TLM1612CCU
7
8
6
4
TLM1612CCUG
5
12
12
12
8
0
7
TLM2412CCU
5,9
0
0
7
TLM2412CCUW
7
0
0
7
TLM2412CCUG
6
32
32
32
40
40
40
36
20
16
16
0
14
14
14
18
18
18
18
8
7
TLM1620CCU
6,9
8
7
TLM1620CCUW
6
8
7
TLM1620CCUG
installed
TGK32
(order separately)
TGK32
(order separately)
TGK42
6
10
10
10
12
16
16
16
20
20
20
20
8
TLM2020CCU
6,9
8
TLM2020CCUW
6
8
TLM2020CCUG
installed
6
9
1-3/0 (Cu),
2/0-3/0 (Al)
1-250 (Cu),
2/0-250 (Al)
6-250
TGK24 and TLK32
(order separately)
TGK32 and TLK20
(order separately)
TGK32
(order separately)
TGK32
(order separately)
TGK42
(order separately)
TGK42
(order separately)
TGK42
(order separately)
TGK42
(order separately)
TLM2420C42
6
11
11
11
13
13
14
14
TLM3220C42
6
6
TLM3220CCU
6,9
6
6-250
6-250
6-250
TLM3220CCUW
6
0
TLM4020CCU
6,9
0
0
TLM4020CCUW
Bottom
Top
Bottom
Top
6
0
0
1-300 (Cu),
2/0-300 (Al)
1-300 (Cu),
2/0-300 (Al)
TLM4220CCU
6
0
0
TLM4222CCU
Bottom
1
No door
2
3
4
5
6
7
8
9
10 kAIC
125 amp maximum branch capacity.
For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.
For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-5.
For main breaker, order THQMVXXXD circuit breaker from page 1-6.
For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
10
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
BuyLog™ Catalog
Rev. 11/13
1-10
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Load Center
1PH
Single-Phase, Three-Wire, 120/240 Vac
Main Lug
Outdoor NEMA 3R
Main Lugs Convertible to Main Breaker
Main Lugs Factory Installed (TLM units convertible to main breaker),
1
Outdoor (NEMA 3R) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
1 Pole,
1/2”
2 Pole,
1/2”
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
1
Ampere
Front
Type
Feed
Box
Number
Equipment
Ground Kit
Product
Number
Rating Spaces
Spaces
Spaces
Spaces
Type
40
70
2
2
5
4
4
4
4
1
1
0
2
2
2
2
4
4
0
8
8
8
8
1
1
0
3
3
3
3
4
4
5
8
8
8
8
Top
Top
Top
Top
Top
Top
Top
R1A
R1A
R41
R1A
R1A
R41
R1
14-4
6-3
6-3
1-2/0
1-2/0
1-2/0
1-2/0
TGK4 (order separately)
TGK4 (order separately)
TGL1 installed
TGL1 (order separately)
TGL1 installed
TL240RCU
TL270RCU
2,8
100
125
125
125
125
Flush
TL510RT
TL412R1
2
2
TL412RT1
TL412R2
TPL412R
2
TGL1 (order separately)
TGL1 (order separately)
2,3
Thermoplastic
Front
Thermoplastic
Front
2,3
125
4
2
8
3
8
Top
R1
1-2/0
TGL1 installed
TPL412RT
4
125
125
125
125
125
4
8
8
14
24
3
4
4
6
12
12
16
16
20
0
4
8
8
8
0
12
16
16
24
24
Top
Top
Top
Top
Top
Bottom
Top
Bottom
Top
Top
Top
R2A
R2A
R3A
R3A
R4A
6-1
6-1
6-1
6-2/0
6-2/0
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
Included
TGK24 (order separately)
TGK32 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK24 (order separately)
TGK42 (order separately)
TGK24 (order separately)
TLM612RCU
4
TLM812RCU
5
TLM812RCU2
TLM1212RCU
TLM2412RCU
7,9
5
6
150
24
12
12
4
30
R6A
1-3/0 (Cu),
2/0-3/0 (Al)
6-250
6-250
6-250
TLM2415RCU
6
200
200
200
12
16
20
6
8
10
24
32
40
10
14
18
24
32
40
R5A
R5A
R6A
TLM1220RCU
TLM1620RCU
TLM2020RCU
6
6
200
200
200
225
24
32
40
42
12
16
20
20
36
16
0
18
6
42
40
40
42
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
R39
1-250 (Cu),
2/0-250 (Al)
TLM2420R42
6
R7A 1-250 (Cu), 2/0-250 (Al)
TGK32 (order separately)
TGK42 (order separately)
TGK42 (order separately)
TLM3220RCU
6
0
R8A
R8A
6-250
TLM4020RCU
6
0
0
1-300 (Cu),
2/0-300 (Al)
TLM4222RCU
1
40-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
10 kAIC.
2
3
4
5
6
7
8
9
125 amp maximum branch capacity.
For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements.
For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL or THHQL circuit breaker. See page 1-5.
For main breaker, order THQMVXXXD circuit breaker from page 1-6.
For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
Main and branch breakers are limited to 70 amps.
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
BuyLog™ Catalog
Rev. 11/13
1-11
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
Section 1
Load Center
1PH
PowerMark Gold and Plus Main Breaker Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Breaker
Indoor NEMA 1
Main Breaker Factory Installed
Product Features
—UL Listed (Panelboards No. 67)
—60°C/75°C Conductor Rating
—Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
—22kAIC RMS symmetrical, Except Where Noted
—6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down.
—For a listing of CSA Listed load centers, visit geindustrial.com.
TM2020CCU
TM820RCUFL
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Front
Type
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Rating Spaces
1
2
100
100
100
100
125
125
125
125
150
150
12
24
20
32
12
24
16
16
16
16
5
12
10
16
5
20
8
22
24
20
32
22
24
24
24
32
32
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Top
Bottom
18
4-1/0
1-2/0
4-1/0
4-1/0
1-2/0
1-2/0
1-2/0
1-2/0
Included
TM1210CCU
TM2410CCU
TM2010CCU
TM3210CCU
TM1212CCU
TM2412CCU
TM1612CCU
0
0
Top
Bottom
7
TGK24, TGK32 and
TLK20 (order separately)
0
0
Top
Bottom
6
TGK24 (order separately)
TGK32 (order separately)
0
0
Top
Bottom
11
18
7
1
2
20
0
8
Top
Bottom
Included
12
8
0
Top
Bottom
TGK24 (order separately)
16
16
32
32
6
Top
Bottom
4
TGK12 (order separately)
TGK24 (order separately)
8
6
Top
Bottom
4
TGK24 installed
TM1612CCUG
TM1615CCU
TM1615CCUG
8
14
14
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Top
Bottom
7
1-3/0 (Cu),
2/0-3/0 (Al)
TGK24 (order separately)
TGK32 (order separately)
8
Top
Bottom
7
1-3/0 (Cu),
2/0-3/0 (Al)
TGK32 installed
This table continued on next page
BuyLog™ Catalog
Rev. 11/13
1-12
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
Section 1
Load Center
1PH
PowerMark Gold and Plus Main Breaker Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Breaker
Indoor NEMA 1
Main Breaker Factory Installed
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Front
Type
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Rating Spaces
150
150
150
200
200
200
200
200
200
200
200
200
200
225
32
24
32
16
16
20
20
20
20
32
40
32
42
42
16
12
16
8
0
0
18
10
14
14
18
18
18
18
6
32
42
42
32
32
40
40
40
40
40
40
42
42
42
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
White Combo
Flush/Surface
Combination
Flush/Surface
White Combo
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Combination
Flush/Surface
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
11
1-3/0 (Cu),
2/0-3/0 (Al)
1-3/0 (Cu),
2/0-3/0 (Al)
1-3/0 (Cu),
2/0-3/0 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-300 (Cu),
2/0-300 (Al)
1-300 (Cu),
2/0-300 (Al)
TGK32 (order separately)
TM3215CCU
TM2415C42
TM3215C42
TM1620CCU
TM1620CCUG
TM2020CCU
36
20
32
32
40
40
40
40
16
0
9
TGK24 (order separately)
TLK32 (order separately)
TGK32 and TLK20
(order separately)
TGK32 (order separately)
11
7
8
8
TGK32 installed
10
10
10
10
16
20
16
20
20
8
TGK32 (order separately)
3
8
TGK24 (order separately)
TGK42 (order separately)
TGK32 (order separately)
TM2020CCUW
8
TM2020CCUG
3
8
TGK32 (order separately)
TGK32 (order separately)
TGK42 (order separately)
TM2020CCUGW
11
13
11
14
14
TM3220CCU
TM4020CCU
TM3220C42
TM4220CCU
TM4222CCU
0
20
0
8
TGK32 and TLK20
(order separately)
TGK42 (order separately)
0
Bottom
Top
Bottom
0
0
TGK42 (order separately)
1
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
2
No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
3
Load Center
1PH
Main Breaker
Outdoor NEMA 3R
4
Outdoor (NEMA 3R) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
100
12
5
20
8
22
Top
R3A
4-1/0
TGK12 (order separately)
TGK24 (order separately)
TGK24 (order separately)
TGK12 (order separately)
TGK24 (order separately)
TGK24 (order separately)
TGK24 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK24 (order separately)
TM1210RCU
100
125
20
12
10
5
0
20
0
8
30
22
Top
Top
R4
R3A
4-1/0
1-2/0
TM2010RCU
TM1212RCU
125
150
150
24
8
16
12
4
8
0
16
32
0
6
14
24
16
32
Top
Top
Top
R4
R5
R5
1-2/0
TM2412RCU
TM815RCUFL
TM1615RCU
1-250 (Cu), 2/0-250 (Al)
1-3/0 (Cu), 2/0-3/0 (Al)
150
150
24
24
12
12
12
36
4
30
42
Top
R6
1-3/0 (Cu), 2/0-3/0 (Al)
1-250 (Cu), 2/0-250 (Al)
TM2415RCU
TM2415R42
18
Top
Bottom
Top
Top
Top
R39
150
200
200
32
8
20
16
4
10
0
16
40
0
6
18
32
16
40
R7
R5
R6
1-3/0 (Cu), 2/0-3/0 (Al)
1-250 (Cu), 2/0-250 (Al)
1-250 (Cu), 2/0-250 (Al)
TGK32 (order separately)
TGK32 (order separately)
TGK24 (order separately)
TGK42 (order separately)
TGK24 (order separately)
TM3215RCU
TM820RCUFL
TM2020RCU
200
24
12
36
18
42
Top
Bottom
Top
Top
Top
R39
1-250 (Cu), 2/0-250 (Al)
TM2420R42
200
200
225
225
32
40
8
16
20
4
16
0
16
0
6
0
6
0
40
40
16
42
R7
R8
R5
R8
1-250 (Cu), 2/0-250 (Al)
1-250 (Cu), 2/0-250 (Al)
1-250 (Cu), 2/0-250 (Al)
1-300 (Cu), 2/0-300 (Al)
TGK32 (order separately)
TGK42 (order separately)
TGK24 (order separately)
TGK42 (order separately)
TM3220RCU
TM4020RCU
TM822RCUFL
TM4222RCU
42
20
Top
4
100-225 amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
BuyLog™ Catalog
Rev. 11/13
1-13
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Plus™ Load Centers
Section 1
Load Center
3PH
Three-Phase, Four-Wire, 208Y/120 Vac2
Main Lugs
Indoor NEMA 1
Main Lugs Factory Installed
Product Features
—UL Listed (Panelboards No. 67)
—60°/75°C Conductor Rating
—Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code
—22kAIC RMS symmetrical Short-circuit Rating Standard
—Bottom feed models available where noted with a “B” suffix.
—For a listing of CSA Listed load centers, visit geindustrial.com.
—Copper breaker mounting stabs with aluminum bus1
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
3 Pole,
1”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
Front Type
3
125
150
150
200
200
200
225
225
12
18
24
18
30
42
30
42
6
4
12
18
24
18
30
42
30
42
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Top
Bottom
4
6-2/0
TGK12 (order separately)
TGK24 (order separately)
TL12412C
3
8
6
Top
Bottom
7
1-3/0 (Cu),
2/0-3/0 (Al)
TGK24 (order separately)
TGK32 (order separately)
TL18415C
3
12
8
8
Top
Bottom
7
1-3/0 (Cu),
2/0-3/0 (Al)
TGK24 (order separately)
TGK32 (order separately)
TL24415C
3
6
Top
Bottom
8
1-250 (Cu),
2/0-250 (Al)
TGK32 (order separately)
TGK32 (order separately)
TGK42 (order separately)
(2) TGL2 (order separately)
(2) TGL2 (order separately)
TL18420C
3
14
20
14
20
10
14
10
14
Top
Bottom
11
13
15
15
1-250 (Cu),
2/0-250 (Al)
TL30420C
Top
Bottom
1-250 (Cu),
2/0-250 (Al)
TL42420C
4
Top
Bottom
1-300 (Cu),
2/0-300 (Al)
TL30422C
4
Top
Bottom
1-300 (Cu),
2/0-300 (Al)
TL42422C
1
Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs, providing copper-to-copper contact at breaker stabs.
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
Alternate main breaker: 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
Not suitable for use as service entrance equipment.
2
3
4
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
BuyLog™ Catalog
Rev. 11/13
1-14
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Plus™ Load Centers
Section 1
Load Center
3PH
Main Lugs
Outdoor NEMA 3R
Three-Phase, Four-Wire, 208Y/120Vac
Main Circuit Breaker or Main Lugs Factory Installed
Main Lugs Factory Installed1
Outdoor (NEMA 3R) Enclosure
TM24420CB
Main
1 Pole,
1”
2 Pole,
1”
Spaces
3 Pole,
1”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
2
125
150
150
200
200
200
225
12
18
24
18
30
42
42
6
4
12
18
24
18
30
42
42
Top
Top
Top
Top
Top
Top
Top
R3
R4
R4
R4
R6
R8
R8
6-2/0
TGK12 (order separately)
TGK24 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK32 (order separately)
TL12412R
2
8
6
1-3/0 (Cu),
2/0-3/0 (Al)
1-3/0 (Cu),
2/0-3/0 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-300 (Cu),
2/0-300 (Al)
TL18415R
2
12
8
8
TL24415R
2
6
TL18420R
2
14
20
20
10
14
14
TGK32 (order separately)
TGK42 (order separately)
TGK42 (order separately)
TL30420R
3
TL42420R
3
TL42422R
1
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
Alternate main breaker 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
Not suitable for use as service entrance equipment.
2
3
Load Center
3PH
Main Breaker
Indoor NEMA 1
Main Breaker Factory Installed4
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
3 Pole,
1”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
Front Type
5
100
100
125
125
150
150
150
150
150
150
200
200
12
18
30
30
24
24
30
30
42
42
24
24
6
4
12
18
30
30
24
24
30
30
42
42
24
24
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Top
Bottom
6
6-1/0 (Cu),
4-1/0 (Al)
TGK12 (order separately)
TGK24 (order separately)
TM12410C
5
8
6
Top
Bottom
6
6-1/0 (Cu),
4-1/0 (Al)
TGK24 (order separately)
TGK32 (order separately)
TM18410C
14
14
12
12
14
14
20
20
12
12
10
10
8
Top
Bottom
Top
11
11
11
11
11
11
13
13
11
11
1-3/0 (Cu),
2/0-3/0 (Al)
TGK32 (order separately)
TGK32 (order separately)
TM30412C
TM30412CB
TM24415C
TM24415CB
TM30415C
TM30415CB
TM42415C
TM42415CB
TM24420C
TM24420CB
1-3/0 (Cu),
2/0-3/0 (Al)
1-3/0 (Cu),
2/0-3/0 (Al
TGL1, TGL2, TGL20,TNG3,
TGN6 (order separately)
8
Bottom
Top
1-3/0 (Cu),
2/0-3/0 (Al)
TGK32 (order separately)
TGK32 (order separately)
TGK32 (order separately)
TGK42 (order separately)
TGK42 (order separately)
TGK32 (order separately)
TGK32 (order separately)
10
10
14
14
8
1-3/0 (Cu),
2/0-3/0 (Al)
Bottom
Top
1-3/0 (Cu),
2/0-3/0 (Al)
1-3/0 (Cu),
2/0-3/0 (Al)
Bottom
Top
1-3/0 (Cu),
2/0-3/0 (Al)
1-300 (Cu),
2/0-300 (Al)
8
Bottom
1-300 (Cu),
2/0-300 (Al)
4
Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.
100 Amp indoor devices UL listed for bottom-feed by installing complete unit upside-down.
5
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
This table continued on next page
BuyLog™ Catalog
Rev. 11/13
1-15
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
PowerMark Plus™ Load Centers
Section 1
Load Center
3PH
Three-Phase, Four-Wire, 208Y/120 Vac1
Main Breaker
Indoor NEMA 1
Main Circuit Breaker Factory Installed
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
3 Pole,
1”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
Front Type
200
200
200
200
225
225
30
30
42
42
42
42
14
14
20
20
20
20
10
10
14
14
14
14
30
30
42
42
42
42
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Combination
Flush/Surface
Front
Top
Bottom
Top
12
12
14
14
15
15
1-250 (Cu),
2/0-250 (Al)
TGK32 (order separately)
TGK32 (order separately)
TGK42 (order separately)
TGK42 (order separately)
(2) TGL2 (order separately)
(2) TGL2 (order separately)
TM30420C
TM30420CB
TM42420C
TM42420CB
TM42422C
TM42422CB
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
Bottom
Top
1-250 (Cu),
2/0-250 (Al)
1-300 (Cu),
2/0-300 (Al)
Bottom
1-300 (Cu),
2/0-300 (Al)
1
Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.
Load Center
3PH
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
3 Pole,
1”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
100
125
150
150
200
200
225
18
30
24
30
30
42
42
8
6
18
30
24
30
30
42
42
Top
Top
Top
Top
Top
Top
Top
R4
R7
R6
R7
R7
R8
R8
6-1/0 (Cu),
4-1/0 (Al)
TGK24 (order separately)
TGK32 (order separately)
TGK32 (order separately)
TM18410R
TM30412R
TM24415R
TM30415R
TM30420R
TM42420R
TM42422R
14
12
14
14
20
20
10
8
1-3/0 (Cu),
2/0-3/0 (Al)
1-3/0 (Cu),
2/0-3/0 (Al)
1-3/0 (Cu),
2/0-3/0 (Al)
1-250 (Cu),
2/0-250 (Al)
1-250 (Cu),
2/0-250 (Al)
1-300 (Cu),
2/0-300 (Al)
TGK32 (order separately)
TGK32 (order separately)
TGK32 (order separately)
TGK42 (order separately)
TGK42 (order separately)
10
10
14
14
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
BuyLog™ Catalog
Rev. 11/13
1-16
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Section 1
Load Center
Generator Panels
Riser Panels
Spa Panels
Product Features - Generator Panels
—Suitable for use in accordance with Article 702 of the National
Electrical Code, ANSI/NFPA 70
—Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits
max.
—Safety and convenience when using a generator - 14,000 peak
wattage, 11,520 continuous load, 48 amps at 240 volts.
—Maintains power to such critical circuits as those for furnace,
pump, refrigerator, lights.
—Connected dual breaker mechanism ensures that only one
source is active at a time.
TL412R250GF
TM830FCUGEN
Generator Panels, Two Interlocked Main Breakers Factory Installed
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
Front Type
30
30
60
60
4
4
4
4
2
2
2
2
8
8
8
8
4
4
4
4
8
8
8
8
Flush Front
Top
Bottom
Top
Bottom
Top
3A
3A
3A
3A
6-1
6-1
6-1
6-1
TGK12 included
TGK12 included
TGK12 included
TGK12 included
TM830FCUGEN
TM830SCUGEN
TM860FCUGEN
TM860SCUGEN
Surface Front
Flush Front
Bottom
Top
Surface Front
Bottom
Generator Panels, Two Interlocked Main Breakers Factory Installed
Outdoor (NEMA 3R) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
30
60
4
4
2
2
8
8
4
4
8
8
Top
Top
R2A
R2A
6-1
6-1
TGK12 included
TGK12 included
TM830RCUGEN
TM860RCUGEN
Riser Panels
Indoor (NEMA 1) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
Front Type
125
20
10
40
20
40
Combination
Flush/Surface Front
Top
9A
6-2/0
TGK12 (order
separately)
TLM2012CCURP
Tap kits required, order separately. See page 1-29.
Auxiliary gutters available. See page 1-29.
Spa Panels
Outdoor (NEMA 3R) Enclosure
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Main Wire Size
(AWG/kcmil)
Cu-Al
Ampere
Rating
Load Center
Type
Feed
Type
Box
Number
Equipment
Ground Kit
Product
Number
Spaces
125
4
2
8
4
8
Factory Included
50A GFCI
Factory Included
60A GFCI
Top
Bottom
Top
1-2/0
TGL1 installed
TL412R250GF
125
4
2
8
4
8
1-2/0
TGL1 installed
TL412R260GF
Bottom
Twist Lock Power Inlets
Product
Receptacles
Amps
Volts
UL
Number
L14-20
L14-30
CS637
20
30
50
120/240
120/240
120/240
Canada, US
Canada, US
Canada, US
T020N
T030N
T050N
BuyLog™ Catalog
Rev. 11/13
1-17
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
Meter Socket LC
1PH
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Ring Type
Meter Main
NEMA 3R
With Bonded Neutrals
Designed and manufactured for quality applications, these
PowerMark Gold Meter Socket Load Centers are a superior
solution to specific applications. Increased durability and
reliability, maximum circuit layout flexibility and ease of
installation add up to lower total installed cost.
The Ringless UL Style meter socket load centers (Florida Meter
Group, Georgia Power, Others) are specifically designed to meet
UL requirements as well as some special features required by spe-
cific utilities. If your local utility does not require specific approval
and you need a ringless meter socket load center, use the Florida
Meter Group style.
TSM2020CFCU
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Bypass
Type
UL
Incoming
Agency
Certification
Product
Number
1/2” Spaces 1/2” Spaces
Front Type
Meter Main - Ring Type, Field Installed Mains
1
100
100
125
200
200
2
2
4
4
4
1
1
2
2
2
4
4
6
6
6
1
1
3
3
3
4
4
6
6
6
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
Semi-Flush
None
None
None
None
None
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
UL
EUSERC
UL
EUSERC
UL
EUSERC
UL
EUSERC
UL
TSL210CFCU
2
1,2,3
Surface
TSL210CSCU
2
1,2,3
Surface
TSL412CSCU
1,4,5
Semi-Flush
TSL420CFCU
2
1,2,3,4
Surface
TSL420CSCU
(NEMA 3R)
EUSERC
Meter Main - Factory Installed Mains
2
2
100
125
150
200
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
Surface
None
None
None
None
OH/UG
OH/UG
OH/UG
OH/UG
UL
UL
UL
UL
TM10RMC
2
2
Surface
TM12RMC
2
2
Surface
TM15RMC
(NEMA 3R)
Outdoor
2
2
Surface
TM20RMC
(NEMA 3R)
1
Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.
Devices include removable closing cap. Order hub separately. See page 1-27.
Surface mounted units have two hub provisions on top end wall.
THQL and THHQL only, 125 amp max. TQDL is obsolete.
2
3
4
5
Restricted
Application Data
Main Wire Size
(AWG/kcmil)
Product
Number
Box
Number
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Field Inst.
Svcs Disc
Equipment
Ground Kit
Cu-Al
TSL210CFCU
TSL210CSCU
TSL412CSCU
TSL420CFCU
TSL420CSCU
TM10RMC
TM12RMC
TM15RMC
TM20RMC
R12
R12
R12
R14
R14
R32
R32
R32
R32
14
14
14
14
14
16
16
16
16
23-1/2
23-1/2
23-1/2
30-3/4
30-3/4
17
17
17
17
4-7/8
4-7/8
4-7/8
5-3/4
5-3/4
5
5
5
5
THQP/THQL
THQP/THQL
THQP/THQL
THQP/THQL
THQP/THQL
Field Installed
Field Installed
Field Installed
Field Installed
6-2/0
6-2/0
6-2/0
1-250
1-250
2-250
2-250
2-250
2-250
TGL1 installed
TGL1 installed
TGL1 installed
TGL1 installed
TGL1 installed
4
4
4
4
TQD
TQD
TQD
TQD
BuyLog™ Catalog
Rev. 11/13
1-18
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
Meter Socket LC
1PH
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Ring Type
Farm Panel
Main Breaker
NEMA 3R
With Bonded Neutrals
Ring Type - Farm Panel - Main Breaker
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
1/2” Spaces
2 Pole,
1/2” Spaces
Total 1-pole
Spaces
Enclosure
Type
Front
Front Type
Bypass
Type
UL
Incoming
Agency
Certification
Product
Number
1,2
200
4
2
8
3
8
Outdoor
Surface
None
OH/UG
UL
TSF420CSCU
(NEMA 3R)
EUSERC
1
Devices include removable closing cap. Order hub separately. See page 1-27.
2
Separate field mounted service disconnect can be added, THQL/THHQL. See wiring diagram on page 1-35.
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Product
Number
Box
Number
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Field Inst.
Svcs Disc
Equipment
Ground Kit
TSF420CSCU
R16
16-3/4
33
6-3/16
THQMV
THQL/THHQL
1-300
TGK12 (order separately)
Ring Type Feed-Thru - Main Breaker
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Front
Type
Bypass
Type
UL
Incoming
Agency
Certification
Product
Number
1/2” Spaces 1/2” Spaces
1
150
150
150
200
200
200
4
8
8
4
8
8
2
4
4
2
4
4
8
3
6
6
3
6
6
8
Outdoor
(NEMA 3R
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
Surface
Surface
Surface
Surface
Surface
Surface
None
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
UL
UL
UL
UL
UL
UL
TSM415CSCU
1
16
16
8
16
16
8
None
None
None
None
None
TSM815CSCU
1
TSM815CSFL
1
TSM420CSCU
1
16
16
16
16
TSM820CSCU
(NEMA 3R
Outdoor
1
TSM820CSFL
(NEMA 3R)
1
Devices include removable closing cap. Order hub separately. See page 1-27.
Application Data
Main Wire Size
Product
Number
Box
Number
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
(AWG/kcmil)
Cu-Al
Equipment
Ground Kit
TSM415CSCU
TSM815CSCU
TSM815CSFL
TSM420CSCU
TSM820CSCU
TSM820CSFL
R36
R16
R37B
R36
R16
R37B
14
16-3/4
14
14
16-3/4
14
28-1/2
33
31-3/4
28-1/2
33
4-1/2
6-3/16
4-1/2
4-1/2
6-3/16
4-1/2
THQMV
THQMV
THQMV
THQMV
THQMV
THQMV
6-350
1-300
6-350
6-350
6-350
6-350
TGL2 included
TGK12 (order separately)
TGK24 included
TGL2 included
TGK12 (order separately)
TGK24 included
31-3/4
BuyLog™ Catalog
Rev. 11/13
1-19
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
Meter Socket LC
1PH
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Ring Type
Narrow, Wide, Over/Under
Main Breaker
With Bonded Neutrals
NEMA 3R
Ring Type - Side by Side - Main Breaker - OH/UG
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Bypass
Type
UL
Incoming
Agency
Certification
Product
Number
1/2” Spaces 1/2” Spaces
Front Type
1
1
1
1
100
125
125
200
100
125
125
200
16
12
16
20
16
12
16
20
8
6
8
10
8
6
8
10
32
24
32
40
32
24
32
40
14
12
14
18
14
12
14
18
32
24
32
40
32
24
32
40
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Semi-Flush
Semi-Flush
Semi-Flush
Semi-Flush
Surface
Surface
Surface
Surface
None
None
None
None
None
None
None
None
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
TSM1610CFCU
TSM1212CFCU
TSM1612CFCU
TSM2020CFCU
TSM1610CSCU
TSM1212CSCU
TSM1612CSCU
TSM2020CSCU
1,2,3
1,2,3
1,2,3
1,2,3
1
Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.
Devices include removable closing cap. Order hub separately. See page 1-27.
Surface mounted units have two hub provisions on top end wall.
2
3
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Box
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Equipment
Ground Kit
Product Number
Number
TSM1610CFCU
TSM1212CFCU
TSM1612CFCU
TSM2020CFCU
TSM1610CSCU
TSM1212CSCU
TSM1612CSCU
TSM2020CSCU
R19
R19
R19
R17
R20
R20
R20
R18
14-3/4
14-3/4
14-3/4
16-3/4
14-3/4
14-3/4
14-3/4
14-3/4
28-1/2
28-1/2
28-1/2
34-1/4
27-5/16
27-5/16
27-5/16
33
7-5/16
7-5/16
7-5/16
7-5/16
5-7/16
5-7/16
5-7/16
6-5/16
THHQL
THHQL
THHQL
THQMV
THHQL
THHQL
THHQL
THQMV
12-2/0
12-2/0
12-2/0
1-300
12-2/0
12-2/0
12-2/0
1-300
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
Ring Type - Extra Wide - Main Breaker
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Bypass
Type
UL
Agency
Product
Number
1/2” Spaces 1/2” Spaces
Front Type
Incoming Certification
2
200
200
32
40
16
20
16
0
6
0
40
40
Outdoor
Outdoor
Surface
Surface
None
None
UG
UG
UL/EUSERC
UL/EUSERC
TSM3220UWCU
2
TSM4020UWCU
2
Devices include removable closing cap. Order hub separately. See page 1-27.
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Box
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Equipment
Ground Kit
Product Number
Number
TSM3220UWCU
TSM4020UWCU
R28
R29
22-1/2
22-1/2
27-7/8
34-7/8
6-1/4
6-1/4
THQMV
THQMV
1-300
1-300
TGK12 (order separately)
TGK12 (order separately)
Ring Type - Top/Bottom - Main Breaker
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Bypass
Type
UL
Agency
Product
Number
1/2” Spaces 1/2” Spaces
Front Type
Incoming Certification
1
200
200
225
225
200
200
225
225
24
32
20
32
24
32
20
32
12
14
10
14
12
14
10
14
36
16
40
16
36
16
40
16
18
6
18
6
18
6
18
6
42
40
40
40
42
40
40
40
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Semi-Flush
Semi-Flush
Semi-Flush
Semi-Flush
Surface
Surface
Surface
Surface
None
None
None
None
None
None
None
None
UG
UG
UG
UG
UG
UG
UG
UG
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
UL/EUSERC
TSM2420UF42
TSM3220UFCU
TSM2022UFCU
TSM3222UFCU
1,2,3
TSM2420US42
1
TSM3220USCU
1
TSM2022USCU
1
TSM3222USCU
1
Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.
Devices include removable closing cap. Order hub separately. See page 1-27.
Surface mounted units have two hub provisions on top end wall.
2
3
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Box
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Equipment
Ground Kit
Product Number
Number
TSM2420UF42
TSM3220UFCU
TSM2022UFCU
R17
R27
R21
16-3/4
14-9/16
14-9/16
34-1/4
43-5/8
43-5/8
7-5/16
7-3/16
7-3/16
THQMV
THQMV
THQMV
1-4/0
1-300
1-300
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
TSM3222UFCU
TSM2420US42
R22
R17
16-3/16
16-3/4
48-1/8
34-1/4
7-3/16
7-5/16
THQMV
THQMV
1-300
1-4/0
TGK12 (order separately)
TGK12 (order separately)
TSM3220USCU
TSM2022USCU
TSM3222USCU
R27
R26
R27
14-9/16
14-9/16
14-9/16
48-1/8
43-5/8
48-1/8
6-3/16
6-3/16
6-3/16
THQMV
THQMV
THQMV
1-300
1-300
1-300
TGK12 (order separately)
TGK12 (order separately)
TGK12 (order separately)
BuyLog™ Catalog
Rev. 11/13
1-20
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
Meter Socket LC
1PH
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Ringless with Bypass
Xcel Energy
With Bonded Neutrals
NEMA 3R
Ringless with Bypass - Xcel Energy
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Main
Type
Bypass
Type
UL
Incoming
Agency
Certification
Product
Number
1/2” Spaces 1/2” Spaces
Front Type
1
1
125
125
125
125
150
150
150
200
200
200
200
200
4
2
8
6
3
3
8
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
MLO
MLO
MB
Surface
Horn Bypass
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
Xcel/UL
TSLR412CSCU
1
4
2
6
Surface
Lever
Bypass
Horn Bypass
TSLB412CSCU
1
1
12
12
4
6
24
24
8
10
12
3
24
24
8
Surface
Surface
Surface
Surface
Surface
TSMR1212CSCU
TSMB1212CSCU
TSMR415CSCU
TSMR2015CSCU
TSMB2015CSCU
6
MB
Lever
Bypass
Horn Bypass
2
MB
1
1
20
20
4
10
10
2
40
40
6
18
18
3
40
40
6
MB
Horn Bypass
MB
Lever
Bypass
Lever
Bypass
Horn Bypass
1
1
MLO
MLO
MB
Surface
TSLB420CSCU
1
4
2
8
3
8
Surface
Surface
Surface
Surface
TSLR420CSCU
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
4
2
8
3
8
Horn Bypass
Horn Bypass
TSMR420CSCU
TSMR2020CSCU
TSMB2020CSCU
1
1
20
20
10
10
40
40
18
18
40
40
MB
MB
Lever
(NEMA 3R)
Bypass
1
Devices include removable closing cap. Order hub separately. See page 1-27.
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Box
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Equipment
Ground Kit
Product Number
Number
2
TSLR412CSCU
TSLB412CSCU
TSMR1212CSCU
TSMB1212CSCU
TSMR415CSCU
TSMR2015CSCU
TSMB2015CSCU
TSLB420CSCU
TSLR420CSCU
TSMR420CSCU
TSMR2020CSCU
TSMB2020CSCU
R31
R12
R30
R20
R31
R30
R18
R14
R31
R31
R30
R18
14-9/16
14
33-9/16
23-1/2
40-1/2
27-5/16
33-9/16
40-1/2
33
30-3/4
33-9/16
33-9/16
40-1/2
33
6-3/16
4-7/8
Field Installed
Field Installed
THHQL
THHQL
THQMV
6-350
6-350
6-350
12-2/0
6-350
6-350
1-300
6-350
6-350
6-350
6-350
1-300
TGK12 (order separately)
TGL1 installed
TGK12 (order separately)
TGK12 (order separately)
TGK12 installed
TGK12 (order separately)
TGK12 (order separately)
TGL1 installed
TGK12 (order separately)
TGK12 installed
2
14-9/16
14-3/4
14-9/16
14-9/16
14-3/4
14
14-9/16
14-9/16
14-9/16
14-3/4
6-3/16
5-7/16
6-3/16
6-3/16
6-5/16
5-3/4
6-3/16
6-3/16
6-3/16
6-5/16
THQMV
THQMV
2
Field Installed
Field Installed
THQMV
2
THQMV
THQMV
TGK12 (order separately)
TGK12 (order separately)
2
THQL and THHQL only. 125 amp max. TQDL is obsolete.
BuyLog™ Catalog
Rev. 11/13
1-21
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
Section 1
Meter Socket LC
1PH
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Ringless
Georgia Power
Florida Meter Group
Main Breaker
NEMA 3R
With Bonded Neutrals
Georgia Power Ringless - Main Breaker
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Bypass
Type
UL
Agency
Product
Number
1/2” Spaces 1/2” Spaces
Front Type
Incoming Certification
1,4
150
200
150
200
–
–
4
4
–
–
2
2
–
–
8
8
–
–
3
3
–
–
8
8
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
Surface
None
None
None
None
OH/UG
OH/UG
OH/UG
OH/UG
UL/GP
UL/GP
UL/GP
UL/GP
TSMR015CSGP
1,4
Surface
Surface
Surface
TSMR020CSGP
1,4
TSMR415CSCUGP
(NEMA 3R)
Outdoor
1,4
TSMR420CSCUGP
(NEMA 3R)
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Box
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Equipment
Ground Kit
Product Number
Number
TSMR015CSGP
TSMR020CSGP
TSMR415CSCUGP
TSMR420CSCUGP
R32A
R32A
R40
18-7/8
18-7/8
14
18-9/16
18-9/16
32
5
5
THQD
THQD
THQMV
THQMV
2-250
2-250
6-350
6-350
–
–
4-1/2
4-1/2
TGL2 included
TGL2 included
R40
14
32
Florida Meter Group MSLC Ringless - Main Breaker
Main
Ampere
Rating
1 Pole,
1” Spaces
2 Pole,
1” Spaces
1 Pole,
2 Pole,
Total 1-pole
Spaces
Enclosure
Type
Bypass
Type
UL
Agency
Product
Number
1/2” Spaces 1/2” Spaces
Front Type
Incoming Certification
150
200
150
200
200
4
2
2
4
4
4
8
3
3
8
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
Surface
None
None
None
None
None
OH/UG
OH/UG
OH/UG
OH/UG
OH/UG
UL/FMG
UL/FMG
UL/FMG
UL/FMG
UL/FMG
TSMR415CSFLFMG
4
8
8
Surface
Surface
Surface
Surface
TSMR420CSFLFMG
4
8
16
16
40
6
16
16
40
TSMR815CSFLFMG
4
8
6
TSMR820CSFLFMG
2
20
18
TSMR2020CSCUFMG
(NEMA 3R)
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Box
Unit Width
(in inches)
Unit Height
(in inches)
Depth
(in inches)
Factory Inst.
Svcs Disc
Equipment
Ground Kit
Product Number
Number
TSMR415CSFLFMG
TSMR420CSFLFMG
TSMR815CSFLFMG
TSMR820CSFLFMG
TSMR2020CSCUFMG
R36A
R36A
R37A
R37A
14
14
14
14
14
28-1/2
28-1/2
31-3/4
31-3/4
34-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
THQMV
THQMV
THQMV
THQMV
THQMV
6-350
6-350
6-350
6-350
6-350
TGL2 included
TGL2 included
TGK24 included
TGK24 included
TGK24 included
3
R40
1
Use FMG unit if Ringless standard UL design is required by your local utility.
No feed through lugs.
Knock outs are the same as R36A.
2
3
4
Feed-thru lugs provided.
BuyLog™ Catalog
Rev. 11/13
1-22
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
Section 1
Meter Socket LC
1PH
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Class 320
NEMA 3R
With Bonded Neutrals
Class 320
Main
1 Pole,
1”
2 Pole,
1”
Spaces
1 Pole,
1/2”
Spaces
2 Pole,
1/2”
Spaces
Total
1-pole
Spaces
Ampere
Rating
Enclosure
Type
Bypass
Type
UL
Incoming
Agency
Certification
Product
Number
Spaces
Front Type
1,2,3
320
400
300
400
400
400
400
400
400
320
320
400
24
12
32
14
40
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
Surf/Semi
None
UG
UG
UG
UG
UG
UG
UG
UG
UG
UG
UG
UG
UL
TM2432RMS
4
0
0
0
0
0
Surf/Semi
Surface
Lever Bypass
Lever Bypass
Lever Bypass
UL
TSDR040UFCU
4
8
4
16
16
32
32
32
32
32
0
6
16
16
40
40
40
40
40
0
UL
FMG
UL
FMG
UL
TSDR830USCU
4
8
4
6
Surface
TSDR840UFCU
1,2,3
24
24
24
24
24
0
12
12
12
12
12
0
14
14
14
14
14
0
Surf/Semi
Surf/Semi
Surf/Semi
Surf/Semi
Surf/Semi
Surf/Semi
Surf/Semi
Surf/Semi
K-4 Bolt-In
Meter Provision
Lever Bypass
TM2440RMKS
1,2,3
UL
TM2440RMRS
1,2,3
None
UL
EUSERC
UL
Xcel
UL
TM2440RMS
1,2,3,4
Lever Bypass
None
TMH2440RMRS
1,2,3,4
TMH2440RMS
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
(NEMA 3R)
Outdoor
4
Lever Bypass
Link Bypass
Link Bypass
UL
TSD032UFCU
4
24
24
12
12
32
32
14
14
42
42
UL
EUSERC
UL
TSDA2432UC42
4
TSDA2440UC42
(NEMA 3R)
EUSERC
1
2
200A main breaker factory installed. Space provided for field mounted TQD-WL sub feed.
For semi-flush applications, order surface enclosure load center and field installed kit, Product number SF400.
Stud provisions only provided.
22 kAIC.
3
4
Application Data
Main Wire Size
(AWG/kcmil)
Cu-Al
Product
Number
Box
Number
Unit Width
(in inches)
Unit Height
(in inches)
Depth
Factory Inst.
Field Inst.
Main Breaker
Equipment
Ground Kit
Ringless
(in inches) Main Breaker
TM2432RMS
No
R24
30-1/4
40
6
TQD
THQL
(1) 800 or (2) 400 compression type;
(1) 1000 or (2) compression type;
(1) 1000 or (2) 350 pressure type
(1) 800 or (2) 400 compression type;
(1) 1000 or (2) 350 pressure type
(1) 800 or (2) 400 compression type;
(1) 1000 or (2) 350 pressure type
(1) 800 or (2) 400 compression type
(2) TGL2
(order separately)
TM2440RMS
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
R24
R24
R24
R24
R33
R23
R24
R24
R33
R33
30-1/4
30-1/4
30-1/4
30-1/4
30-1/4
30-1/4
30-1/4
30-1/4
30-1/4
30-1/4
40
40
40
40
33
40
40
40
33
33
6
TQD
THQD
THQD
THQD
THQD
TQD
TQD
THQD
(2) TGL2
(order separately)
(2) TGL2
(order separately)
(2) TGL2
(order separately)
(2) TGL2
(order separately)
(2) TGL2
(order separately)
(2) TGL2
(order separately)
(2) TGL2
(order separately)
(2) TGL2
(order separately)
(2) TGL2
TMH2440RMS
TSDA2432UC42
TSDA2440UC42
TSD032UFCU
TM2440RMKS
TM2440RMRS
TMH2440RMRS
TSDR040UFCU
TSDR840UFCU
6
6
THQL/THHQL
TQD/THQD
THQL/THHQL
TQD
6
6-3/32
6
(1) 800 or (2) 400 compression type
(1) 800 or (2) 400 compression type
(1) 800 or (2) 400 compression type;
(1) 1000 or (2) 350 pressure type
(1) 800 or (2) 400 compression type;
(1) 1000 or (2) 350 pressure type
(1) 800 or (2) 400 compression type;
(1) 1000 or (2) 350 pressure type
(1) 800 or (2) 400 compression type
6
TQD
TQD
6
THQD
THQD
THQD
THQD
6-3/32
6-3/32
TQD/THQD
TQD/THQD
(order separately)
(2) TGL2
(1) 800 or (2) 400 compression type
(order separately)
BuyLog™ Catalog
Rev. 11/13
1-23
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Field Installed Accessories
PowerMark Gold Main Circuit Breaker Kit
For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Product
Number
Description
1
Main Circuit Breaker Kit - Order appropriate THQL
TQMH000
10kAIC or THHQL 22kAIC breakers separately
1
Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to
convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load
centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
TQMH000
PowerMark Plus™ Equipment Ground Kits
Product
Description
Standard Package Quantity
Number
(4) 14-8Cu/12-8AL,
20
TGL1
(3) 14-4Cu/6-4AL
(8) 14-8Cu/12-8AL,
(6) 14-4Cu/6-4AL
(7) 14-8Cu/12-8AL, (3) 14-4Cu/6-4AL,
(2) 14-4Cu/12-4AL, (1) 14-2Cu/AL
(1) 6-2/0Cu/Al Number of Terminals,
Equipment Ground Kits
(3) 10-1/0 Cu/Al Number of Terminals
for 400 and 600 Amp
TGL2
1
20
20
20
1
TGL2
1
TGL8
2
TGL20
3
TNG3
4
(6) 10-1/0 Cu/Al Number of Terminals
for 400 and 600 Amp
1
TNG6
1
TGL2, TGL4 and TGL8 mount interchangeably
2
Add-on Equipment Ground Lug (for use on any TGL Kit)
TGL20 combined with TGL1
3
Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole
4,5
PowerMark Gold Equipment Ground and Isolated Ground Bar Kits
Product
Number
Description
Standard Package Quantity
4-hole Ground
12-hole Ground
24-hole Ground
32-hole Ground
42-hole Ground
1
1
1
1
1
TGK4
TGK12
TGK24
TGK32
TGK42
TGK12
4
6-12 circuit indoor load centers use PowerMark Plus style neutrals and grounds
Add TGKIS for isolated ground and mount to ground kit.
5
TGK12 with TGKIS
BuyLog™ Catalog
Rev. 11/13
1-24
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Field Installed Accessories
PowerMark Plus™ Neutral Kits
Wire
Range
(5) 14-1/0
(3) 1-300
6-2/0
Standard
Package Quantity
Product
Number
Description
1
400 & 600 Amp PowerMark Plus™ Neutral Kit
400 & 600 Amp PowerMark Plus™ Neutral Kit
Add-on neutral lug for 100-200 Amp PowerMark
Plus load centers
1
1
1
TNLK1
1
TNLK2
286A8894G1
Add-on neutral lug for 100-200 Amp PowerMark
Plus load centers
1-300 Cu or
2/0-300 Al
1
192A7663G13
192A7663G13
286A8894G1
1
Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole
PowerMark Gold Neutral Kits
Wire
Range
6-2/0
Standard
Package Quantity
1
Product
Number
TNLK20
Description
PowerMark Gold Neutral Kit -
Mounted on top of neutral only
PowerMark Gold Neutral Kit -
Mounted on top of neutral only
6-250
1
TNLK250
TNLK250
PowerMark Gold Neutral/Ground Lug Kits
Mounted on any neutral or ground position by removing the termination screw
Wire
Range
6-2/0
6-250
6-300
Standard
Package Quantity
Product
Number
TLK20
TLK250
TLK300
Description
Neutral/Ground Lug Kit
Neutral/Ground Lug Kit
Neutral/Ground Lug Kit
1
1
1
TLK20
TLK250
Isolated Ground Bus Bars Equipment Ground Kit
Standard
Package Quantity
Product
Number
Description
Isolated Ground Bar Kit (order with
TGK Equipment Ground Kits)
1
TGKIS
Isolated Ground Bar Feet (Order with TGK8)
1
TGKIS2
TGK12 with TGKIS
Subfeed Lug Kits
Standard
Package Quantity
Product
Number
Description
125A 2 Pole Plug-in
1
1
1
1
1
THLK2125
THLK2150
THLK2200
THLK3125
THLK3225
150A 2 Pole Plug-in - For use with PowerMark Gold only
200A 2 Pole Plug-in - For use with PowerMark Gold only
125A 3 Pole Plug-in
225A 3 Pole Plug-in - For use with 3 phase only
Sub-feed and Feed-thru Lugs
UL Listed
For use in load centers to economically supply power to a subpanel.
Product
Number
Poles
Ampere Rating
THLK2125
2
3
2
2
3
125
125
150
200
225
THLK2125
THLK3125
THLK2150
THLK2200
THLK3225
1
1
2
1
2
For use with PowerMark Gold load centers only
For use with three-phase load centers only. Includes mounting base.
BuyLog™ Catalog
Rev. 11/13
1-25
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Field Installed Accessories
PowerMark Plus™ Main Lug Kits
Product
Number
Description
Wire Range (Cu/Al)
150 Amp PowerMark Plus™ Replacement Main Lug kit
200 Amp PowerMark Plus™ Replacement Main Lug kit
2-3/0
1-250
THLK150
THLK200
THLK200
PowerMark Gold Main Lug Kits
Product
Number
Description
Wire Range (Cu/Al)
125 Amp PowerMark Gold Replacement Main Lug kit
200 Amp PowerMark Gold Replacement Main Lug kit
225 Amp PowerMark Gold Replacement Main Lug kit
6-2/0
6-250
6-300
TMLK125
TMLK200
TMLK225
For replacement of main lugs on 125 amp load centers; TLM load centers include main lugs.
PowerMark Gold main lug kits - TMLK200
Door Lock
Standard
Package Quantity
Product
Number
Description
For indoor load centers larger than 12 circuits (Does not fit TPL412)
10
TDL106
TDL106
Circuit Directory
Standard
Package Quantity
Product
Number
Description
Card and holder with pressure-sensitive backing.
Mounts inside the door.
1
TD42
TD42
Touch-up Paint
Standard
Package Quantity
Product
Number
Description
12 3/4 oz. spray can of light gray enamel
1
TSP61
TSP61
BuyLog™ Catalog
1-26
Rev. 11/13
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Field Installed Accessories
Front Filler Plates
Standard
Package Quantity
Product
Number
Description
TFH
1/2” Front Filler Plate
1” Front Filler Plate
100
50
TFH
TQLFP1
Covers 1/2” rectangular breaker knockouts
Covers 1” rectangular breaker knockouts
Universal Raintight Hubs
Standard
Package Quantity
Product
Number
Description
Base Size (in.)
3/4” Diameter
1” Diameter
1-1/4” Diameter
1-1/2” Diameter
2” Diameter
2-1/2” Diameter
3” Diameter
Closing Cap
2” Diameter
2-1/2” Diameter
3” Diameter
3-1/2” Diameter
4” Diameter
4” Cover Plate
3
3
3
3
3
3
3
3
4
4
4
4
4
4
10
10
10
10
10
10
5
TC75
TC100
TC125
TC150
TC200
TC250
TC300
TCCP
TCU27
TCU28
TCU30
TCU35
TC150
10
1
TCU40
TCUP
1
For 40 and 42 circuit units in R8 boxes only.
Door Handle
Standard
Package Quantity
Product
Number
Description
Replacement Door Handle Universal
1
TRL22
TRL22
PowerMark Gold Cross Arm
Standard
Package Quantity
Product
Number
Description
Replacement cross arm for
PowerMark Gold load centers
1
LCCROSSARM
LCCROSSARM
BuyLog™ Catalog
Rev. 11/13
1-27
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Field Installed Accessories
PowerMark Gold Main Breaker Retainers
Product
Number
Description
Breaker Type
Travel Trailer Main Breaker Retainer Kit
for THQP Breakers
THQP
THQPSBK
For use on PowerMark Plus™ load centers with
THQL
THQL
THQL
THQLRK
THQLRK
THQL Breakers 225A max
For use with 12 - 42 circuit PowerMark Gold
load centers with THQL Breakers
For use with 6 - 8 circuit PowerMark Gold
load centers with THQL Breakers
THQLRK1
THQLRK2
For use with TM/TLM1212CCU Mod 2 current model
For use with 6 - 42 circuit PowerMark Gold
load centers with THQL Breakers. Similar to
THQLRK1 but it does not take up a breaker space.
THQL
THQL
THQLRK3
THQLRK4
For main lug load centers utilizing a back fed branch breaker as a main
THQLRK1
Handle Locks - Padlocking
Product
Number
Description
Breaker Type
THQP Padlocking Handle Lock
THQL Padlocking Handle Lock
TQD Padlocking Handle Lock
THQP
THQL
TQD
TQPPL
THP100
TQDPLD1
Snap on handle lock
Padlock not included
THL103
Handle Locks - Non Padlocking
Product
Number
Description
Breaker Type
THQP Non Padlocking Handle Lock
THQL Non Padlocking Handle Lock
THQP
THQL
TQPL
THL103
Snap on handle lock
THT1
Handle Ties
Product
Number
Description
Breaker Type
1
Handle Ties for THQP Breakers - Solid Snap-on
Trip Indicating
Handle Ties for THQP Breakers - For 2 THQPs
separated by 2 side-by-side THQPs
THQP
THT1
1
THQP
THT2
TQB
TQC
TQL
TQB
TQC
TQL
TQB
TQC
TQL
1
Snap-on Handle Tie - Trip Indicating
Snap-on Handle Tie - Solid
TQHT1
THT104
1
THT104
2
Multiwire Branch Breaker
Handle Tie Kits
TQ3HTK
TQ4HTK
3
All multi-pole breakers have internal common trip
Handle ties provide manual on-off capability only between one-pole devices
1
For two single-pole breakers
2
For three single-pole breakers - kit includes (10) pcs.
3
For four single-pole breakers - kit includes (10) pcs.
THT2
TQHT1
BuyLog™ Catalog
1-28
Rev. 11/13
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Field Installed Accessories
Load Center Hardware Kits Hardware
Standard
Product
Description
Package Quantity
Number
PowerMark Plus™ hardware kit: TQD THQD Main or
THLK main lug kit in a TLM load center, installation
instructions and front mounting screws
Powermark Gold Bond Screw Kit Screw 100 - 200A
Powermark Gold Bond Screw Kit 225A
Powermark Gold Hardware kit
1
LCHDKIT
1
1
1
TBS
TBS22
THDWRKIT
containing 20 front mounting screws
Powermark Gold Hardware kit
1
THDWRKIT2
containing 10 interior mounting screws
Generator Interlock Kit
Standard
Package Quantity
Product
Number
Description
Load Center Generator Interlock Kit
MSLC Generator Interlock Kit
MSLC Generator Interlock Kit
MSLC Generator Interlock Kit
MSLC Generator Interlock Kit
1
1
1
1
1
THQLLX1
THQLLX4
THQLLX8CU
THQLLX8DR
THQLLX8FL
PowerMark Gold Auxiliary Gutter Enclosures
Product
Number
Description
24” Auxiliary Gutter Enclosure
28” Auxiliary Gutter Enclosure
28” Auxiliary Gutter Enclosure Flush
33” Auxiliary Gutter Enclosure
39” Auxiliary Gutter Enclosure
43” Auxiliary Gutter Enclosure
43” Deep Auxiliary Gutter Enclosure
TMAGB24
TMAGB28
TMAGB28F
TMAGB33
TMAGB39
TMAGB43
TMAGB43D
PowerMark Gold Gutter Tap Kits
Product
Number
Description
250 kcmil Lugs Gutter Tap Kit - one kit per phase required
500 kcmil Lugs Gutter Tap Kit - one kit per phase required
750 kcmil Lugs Gutter Tap Kit - one kit per phase required -
Not for use with riser panels
TMGT250
TMGT500
TMGT750
Meter Socket Load Center Flange Kits
Product
Number
Description
Semi-Flush Kit 400A for MSLC
SF400
Semi-Flush Kit 400A for MSLC Adjustable
Semi-Flush Kit 200A for MSLC Adjustable
SF400A
SF200A
Surge Protectors
Product
Number
Description
SurgePro AC 27KA Panel-Mount Surge Protector
THQLSURGE
BuyLog™ Catalog
Rev. 11/13
1-29
Data subject to change
Download from Www.Somanuals.com. All Manuals Search And Download.
without notice
Page Updated 08 / 2016
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
A
A
Wiring Diagrams
G
G
G
E
Breaker Fill
Breaker Symbol
1” THQL
1/2” THQP
1
1
—
2
TL240SCU, RCU
TL270SCU, RCU
TL510RT
Wire Range (AWG/kcmil)
Terminal Symbol
Cu
14-8
14-4
6-2
Al
12-8
12-4
6-2
o
•
A
B
C
D
E
MAIN LUGS
MAIN LUGS
C
C
C
14-1/0
6-2/0
1-300
1-300
6-1
12-1/0
6-2/0
2/0-300
1-300
6-1
F
TPL412C, TL412C, TPL412R, TL412R1,
TL412R2, TL412R250GF, TL412R260GF
TPL412CT, TL412CT
TPL412RT, TL412RT1
G
6-3
6-3
MAIN
BREAKER
C
E
F
F
F
F
F
MAIN
BREAKER
MAIN
BREAKER
F
F
SUB-FEED
LUGS
E
TM860FCUGEN, TLM830FCUGEN,
TM860SCUGEN, TLM830SCUGEN,
TM860RCUGEN, TLM830RCUGEN
TLM812FCU, SCU,
FCUD, SCUD, RCU
TM815RCUFL
TM820RCUFL
TLM612FCU, SCU
FCUD, SCUD, RCU
C
C
C
C
C
C
C
C
C
C
E
MAIN
MAIN
MAIN
TLM2012CCURP
TM1210RCU, TM1212RCU, TLM1212RCU
TM1210CCU, TM1212CCU, TLM1212CCU
C
E
MAIN
C
MAIN
C
F
F
MAIN
C
C
TM1615CCU, TM1615RCU, TM1620CCU,
TLM1620CCU, TLM1620RCU
TLM1612CCU, TM1612CCU, TM1612RCU
TLM812RCU2
TM2420R42B
BuyLog™ Catalog
Rev. 11/13
1-30
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Wiring Diagrams
MAIN
C
E
MAIN
C
Breaker Fill
Breaker Symbol
1” THQL
1/2” THQP
1
1
—
2
TM2020CCU, TM2020RCU
TLM2020CCU, TLM2020RCU
TM2010CCU, TM2010RCU
Wire Range (AWG/kcmil)
MAIN
C
MAIN
C
E
Terminal Symbol
Cu
14-8
14-4
6-2
Al
12-8
12-4
6-2
o
•
A
B
C
D
E
14-1/0
6-2/0
1-300
1-300
6-1
12-1/0
6-2/0
2/0-300
1-300
6-1
F
TM2410CCU, TM2412CCU
TM2412RCU, TLM2412CCU, TLM2412RCU
TM2415RCU, TLM2415RCU
G
6-3
6-3
C
E
C
C
E
MAIN
C
E
MAIN
MAIN
MAIN
TM3215CCU, TM3215RCU
TM3220CCU, TM3220RCU, TLM3220CCU
TM3210CCU
TLM2420C42, TM2415C42
MAIN
MAIN
C
E
C
E
C
MAIN
MAIN
C
TM4020CCU, TM4020RCU
TLM4020CCU, TLM4020RCU
TM4222RCU, TLM4222CCU
TLM4222RCU, TM4222CCU
TM12410
TL12412
C
E
MAIN
TM3215C42, TLM3220C42, TM3220C42
BuyLog™ Catalog
Rev. 11/13
1-31
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Wiring Diagrams
Breaker Fill
MAIN
Breaker Symbol
1” THQL
1/2” THQP
C
C
D
MAIN
1
1
—
2
C
C
D
Wire Range (AWG/kcmil)
Terminal Symbol
Cu
14-8
14-4
6-2
Al
12-8
12-4
6-2
o
•
A
B
C
D
E
14-1/0
6-2/0
1-300
1-300
6-1
12-1/0
6-2/0
2/0-300
1-300
6-1
TL18415, TL18420
TL24415, TM24415
F
G
6-3
6-3
MAIN
MAIN
MAIN
C
C
C
D
C
C
D
C
MAIN
D
D
D
C
C
C
C
C
C
C
MAIN
TL24440, TM24420
TM18410
TM30412
TM30415, TL30420, TM30240, TL30422
BuyLog™ Catalog
Rev. 11/13
1-32
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol
1” THQL
1/2” THQP
1
1
—
2
Wire Range (AWG/kcmil)
Terminal Symbol
Cu
14-8
14-4
6-2
Al
12-8
12-4
6-2
o
•
A
B
C
D
E
14-1/0
6-2/0
1-300
1-300
6-1
12-1/0
6-2/0
2/0-300
1-300
6-1
F
G
6-3
6-3
MAIN
MAIN
C
C
D
C
C
C
D
TL42420, TM42415C, TM42420
TL42422
BuyLog™ Catalog
Rev. 11/13
1-33
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Wire Range (AWG/kcmil)
Wiring Diagrams
Terminal Symbol
Cu
14-8
14-4
6-2
Al
12-8
12-4
6-2
o
•
A
B
C
D
E
14-1/0
6-2/0
1-300
1-300
6-1
12-1/0
6-2/0
2/0-300
1-300
6-1
Breaker Fill
Breaker Symbol
1” THQL
1/2” THQP
1
1
—
2
F
G
6-3
6-3
WHM
A
C B B C
MAIN
WHM
A
A
A
TM10RMC, TM12RMC, TM15RMC, TM20RMC,
TSMR015CSGP, TSMR020CSGP
TSL210CSCU, TSL210CFCU
B
C
WHM
WHM
WHM
MAIN
A
A
Load
Load
D D C
B
A
A
A
A
A
A
E
TSM415CSCU, TSM420CSCU, TSMF415CSFL,
TSMF420CSFL, TSMR415CSCUGP, TSMR420CSCUGP,
TSMR415CSFLFMG, TSMR420CSFLFMG
TSL420CSCU, TSL420CFCU
TSL412CSCU
SPACE PROVIDED
FOR 110A PARALLEL
MAIN BREAKER
WHM
WHM
MAIN
BREAKER
WHM
MAIN
BREAKER
MAIN
BREAKER
C
C
C
C
C
C
C
C
TSF420CSCU
TSM815CSCU, TSM820CSCU
TSM1212CSCU, TSM1212CFCU
BuyLog™ Catalog
Rev. 11/13
1-34
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Wire Range (AWG/kcmil)
Wiring Diagrams
Terminal Symbol
Cu
14-8
14-4
6-2
Al
12-8
12-4
6-2
o
•
A
B
C
D
E
14-1/0
6-2/0
1-300
1-300
6-1
12-1/0
6-2/0
2/0-300
1-300
6-1
Breaker Fill
Breaker Symbol
1” THQL
1/2” THQP
1
1
—
2
F
G
6-3
6-3
WHM
MAIN
BREAKER
WHM
MAIN
BREAKER
C
C
C
C
TSM2020CSCU, TSM2020CFCU
TSM1610CSCU, TSM1610CFCU, TSM1612CFCU, TSM1612CSCU
D
C
E
C
MAIN
BREAKER
WHM
WHM
C
E
MAIN
D
D
C
MAIN
C
E
C
A
MAIN
BREAKER
Sub feed lugs
WHM
A
WHM
B
A
PH
B
PH
NEUTRAL
N
TSM815CSFL, TSM820CSFL, TSMF815CSFL,
TSMF820CSFL, TSMR815CSFLFMG,
TSMR820CSFLFMG
TSM3220USCU, TSM3220UFCU, TSM3222USCU,
TSM3222UFCU
TSM2420UF42
TSM3220UWCU
MAIN
BREAKER
WHM
WHM
C
E
WHM
MAIN
BREAKER
WHM
MAIN
BREAKER
TSMR2020CSCU, TSMR2015CSCU,
TSMB2020CSCU, TSMB2015CSCU
TSLR420CSCU, TSLR412CSCU,
TSLB412CSCU, TSLB420CSCU
TSM4020UWCU
TSMR1212CSCU, TSMB1212CSCU
BuyLog™ Catalog
Rev. 11/13
1-35
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Wire Range (AWG/kcmil)
Wiring Diagrams
Terminal Symbol
Cu
14-8
14-4
6-2
Al
12-8
12-4
6-2
o
•
A
B
C
D
E
14-1/0
6-2/0
1-300
1-300
6-1
12-1/0
6-2/0
2/0-300
1-300
6-1
Breaker Fill
Breaker Symbol
1” THQL
1/2” THQP
1
1
—
2
F
G
6-3
6-3
D
C
Space for
WHM
Field-installed
TQD Breaker
E
C
Ground
termination
WHM
200A
Main
Breaker
MAIN
C C
C
D
L1
N
L2
D
D
C
MAIN
BREAKER
E
WHM
A PH
B PH
NEUTRAL
TM2440RMKS, RMRS, RMS,
TMH2440RMS, TMH2440RMRS
TSMR2020CSCUFMG
TSM2022USCU, TSM2022UFCU
Space for
Field-installed
Breaker
Line
WHM
C
C
C
MAIN
C
E
WHM
L1
N
L2
MAIN
C
E
C
Neutral
TSM2015URCU
TSDA2432UC42, TSDA2440UC42
Space for Field Installed
Second Main Breaker
Space for Field Installed
Second Main Breaker
Space for Field Installed
Second Main Breaker
WHM
WHM
WHM
MAIN
C
E
MAIN
MAIN
TSD032UFCU
TSDR040UFCU
TSDR840UFCU
BuyLog™ Catalog
Rev. 11/13
1-36
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Indoor Enclosures
Knockouts
Symbol
A
•
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
Z
5/16
–
3/8
1/2
–
–
–
–
–
–
–
–
–
1/2
–
–
–
–
–
–
–
–
3/8
1/2
3/4
–
–
–
–
–
–
–
1/2
3/4
–
–
–
–
–
–
–
–
3/4
–
–
–
–
–
–
–
3/8
1/2
3/4
1
–
–
–
–
–
–
1/2
3/4
1
–
–
–
–
–
–
1/2
3/4
1
–
–
–
3/4
1
–
–
–
3/4
1
–
–
–
–
1
–
–
–
–
1
–
–
–
–
–
–
–
–
3/4
1
–
–
–
–
1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3/4
1
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
2
–
–
–
3/4
1
–
–
–
–
–
–
–
–
–
–
–
–
–
3/4
1
–
–
1/2
3/4
1
–
–
–
–
Conduit
Size
in
1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
1 1/4 1 1/4
1 1/4 1 1/4
1 1/2 1 1/2 1 1/2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2
–
2
1 1/2 1 1/2 1 1/2
2
–
–
–
–
inches
–
–
–
–
–
–
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
–
–
–
–
–
2
2
2 1/2 2 1/2 2 1/2 2 1/2
2 1/2 2 1/2
3
2 1/2 2 1/2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3
–
–
3
–
–
–
–
–
–
–
–
–
–
–
–
3 1/2 3 1/2 3 1/2
–
–
–
–
4
Dimensions (in inches)
Box No.
Width
Height
Depth
X
1A
2
2A
3A
4
4A
6
7
5 11/16
7 1/2
7 1/4
11 9/16
14
14
14
14
14
14
14
14
14
14
14
14
16
10 1/4
9 7/32
9
11 3/8
19
3 3/8
3 5/16
3
J
D
A
A
H
D
A
H
3 3/8
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
4 5/8
5 13/16
6 3/32
3 3/8
A
D
19
23
A
G
G
D
X
X
24 11/16
26 7/16
28 7/16
28 7/16
33 3/16
35 7/16
39 3/16
43 7/16
43 7/16
45 1/8
59 7/8
16
W
8
9
A
W
A
A
9A
11
12
13
14
15
16
17
18
H
H
A
W
D
B
A
J
X
D
Box 1A
Box 2
20
14
C
G
Z
Y
A
H
D
H
K
Q
Q
A
A
Q
M
H
A
A
D
H
B
K
H
D
D
K
G
D
G
C
D
F
D
A
Y
A
Y
A
A
D
M
D
H
A
Z
K
G
H
Y
D
B
B
Box 2A
Box 3A
Box 4, 6, 7, 8, 9, 11, 12, 13, 14
Box 4A, 9A
B
T
J G U
G J
V
D
K
B
D
B
C
B
S
B
C
C
B
D
D
B
B
B
B
B
B
B
B
D
D
B
B
K
P
K
K
H
B
S
S
A
A
A
C
A
K
K
AA
P
B
J
AA
B
R
B
C
D
D
A
A
H
A
B
D
D
D
D
D
B
D
D
D
D
D
B
B
C
B
N
C
B
C
A
B
B
A
B
B
B
B
A
S
B
P
C
C
N
B
B
B
D
D
A
C
P
B
J
P
A
S
B
A
K
A
K
B
C
P
C
K
C
B
T
J
J
G
B
B
Box 18
Box 15
Box 16
Box 17
BuyLog™ Catalog
Rev. 11/13
1-37
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Outdoor Enclosures
Knockouts
Symbol
A
•
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
Z
AA BB
CC DD
9/16
–
3/8
1/2
–
–
–
–
3/8
1/2
3/4
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
1
–
–
–
–
–
–
1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
–
–
–
–
–
–
1/2
3/4
1
–
–
–
–
–
–
–
–
–
–
–
1/2
–
1/2
3/4
–
–
1/2
3/4
1
1/2
3/4
1
–
–
–
–
1/2
3/4
–
–
1/2
3/4
–
–
–
1/2 1/2
3/4
–
3/4
1
3/4
1
3/4
–
3/4
1
3/4
1
–
3/4
1
3/4
1
–
–
–
Conduit
Size
–
–
–
–
–
–
–
–
1 1/4
1 1/2
–
–
1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
1 1/4 1 1/4
–
1 1/4 1 1/4 1 1/4
1 1/2 1 1/2 1 1/2
–
1 1/4 1 1/4
in
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2
–
2
1 1/2 1 1/2 1 1/2
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2
Inches
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
2
–
–
–
–
–
–
2
2
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
–
–
–
–
–
–
–
2 1/2 2 1/2 2 1/2 2 1/2
2 1/2 2 1/2
–
2 1/2
2 1/2
3
2 1/2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3
3
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3 1/2 3 1/2 3 1/2
–
3 1/2
4
–
–
–
–
–
–
–
–
–
4
–
Dimensions (in inches)
Box No.
Width
Height
Depth
R1
R1A
R1B
R2A
R3A
R3
R4A
R4
R5A
R5
R6A
R6
R7A
R7
R8A
R8
R9
7 1/2
7 1/4
7 3/8
11 1/4
13
12 1/2
14 11/16
14
13
12 1/2
13
14
14 11/16
14
9 7/32
10
13
11 1/8
21 1/2
21 3/16
30 3/16
33 3/16
29
3 5/16
3 3/4
3 3/4
3 1/4
5
4 5/8
5 1/4
4 5/8
5
X
D
HUB
A
D
A
W
X
X
28 11/16
33
4 5/8
5
W
D
35 7/16
34 3/16
39 3/16
43 1/4
43 11/16
45 15/16
48 15/16
59 15/16
13 1/4
4 5/8
5 1/4
4 5/8
6 13/32
5 3/4
5 27/32
6 7/8
6 7/8
4
A
D
D
B
W
K
G
14 21/32
14
16
20
20
B
D
X
Box R1A
Box R1
Box R2A
R10
R11
R41
7 1/2
Q
R
A
D
K
D
A
U
U
Q
Q
R
J
D
H
D
B
Q
Box R3, R4, R5, R6, R7
Box R8
Box R3A, R5A, R6A
Box R4A, R7A
Mounting provided
for universal hubs
L
R
C
L
J
C
C
C
B
C
R
K
B
R
P
K
K
J
B
P
B
B
K
C
V
B
C
C
K
B
J
T
U
G
B
R8A
Box R9
Box R10, R11
Box R41
BuyLog™ Catalog
Rev. 11/13
1-38
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Meter Socket Load Centers
Knockouts
Symbol
A
•
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
EE
FF
5/32
–
3/8
1/2
–
–
–
–
–
–
–
–
–
3/8
1/2
3/4
1
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
1
–
–
–
–
–
–
1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3/8
–
1/2
–
1/2 1/2
3/4 3/4
–
1/2
3/4
1
1/2
3/4
1
–
–
–
–
1/2
3/4
–
–
–
1/2
3/4
–
–
–
1/2
3/4
1
1/2
–
1/2
3/4
1
3/4
–
3/4
1
3/4
1
3/4
–
3/4
1
3/4
1
3/4
1
–
3/4
1
Conduit
Size
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1 1/4
1 1/2
–
–
1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4
1 1/4 1 1/4
–
1 1/4 1 1/4 1 1/4
1 1/2 1 1/2 1 1/2
–
1 1/4 1 1/4
–
1 1/4 1 1/4
in
–
–
–
–
–
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2
–
2
1 1/2 1 1/2 1 1/2
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
2
–
–
–
–
–
–
2
2
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
2
–
–
–
–
–
––
–
2 1/2 2 1/2 2 1/2 2 1/2
2 1/2 2 1/2
–
2 1/2
2 1/2
3
2 1/2 2 1/2 2 1/2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3
3
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3 1/2 3 1/2 3 1/2
–
3 1/2
4
–
–
–
–
–
–
–
–
4
–
Dimensions (in inches)
Box No.
Width
Height
Depth
R12
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
14
14
23 1/2
30 3/4
33
33
34 1/4
33
28 1/2
27 5/16
43 5/8
48 1/8
40
4 7/8
5 3/4
6 3/16
6 3/16
7 5/16
6 5/16
7 5/16
5 7/16
7 3/16
7 3/16
6
16 3/4
16 3/4
16 3/4
14 3/4
16 3/4
14 3/4
14 9/16
16 3/16
30 1/4
30 1/4
A
B
A
F
Q
K
F
Y
W
E
B
B
B
Semi-Flush Only
Semi-Flush Only
40
6
F
EE
F
HUB
PUNCHING
HUB
PUNCHING
F
A
A
F
B
B
C
B
B
C
EE
EE
Box R12
Box R14
G
B
B
B
C
C
C
CC
CC
G
B
B
B
B
C
B
C
CC
CC
C
B
B
B
B
B
B
B
B
B
B
B
B
C
C
C
B
B
BB
B
A
B
B
A
C
B
B
B
C
BB
B
CC
B
BB
B
C
B
Box R16
B
C
B
C
C
G
B
B
B
B
B
B
B
K
A
C
B
B
G BB
C
C
C
C
C
CC
C
CC
CC
Q
B
B
B
B
B
A
BBBB
B
Box R17, R18
Box R19, R20
S
S
Z
Z
Z
S
S
R
R
D
K
K
B
G
R
G
K
R
B
AA
AA
D
D
C
K
D
B
D
Box R21, R22
Box R23
Box R24
BuyLog™ Catalog
Rev. 11/13
1-39
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Meter Socket Load Centers
Knockouts
Symbol
A
•
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
EE
FF
5/32
–
3/8
1/2
–
–
–
–
–
–
–
–
–
3/8
1/2
3/4
1
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
1
–
–
–
–
–
–
1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3/8
–
1/2
–
1/2 1/2
3/4 3/4
–
1/2
3/4
1
1/2
3/4
1
–
–
–
–
1/2
3/4
–
–
–
1/2
3/4
–
–
–
1/2
3/4
1
1/2
–
1/2
3/4
1
3/4
–
3/4
1
3/4
1
3/4
–
3/4
1
3/4
1
3/4
1
–
3/4
1
Conduit
Size
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1 1/4
1 1/2
–
–
1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4
1 1/4 1 1/4
–
1 1/4 1 1/4 1 1/4
1 1/2 1 1/2 1 1/2
–
1 1/4 1 1/4
–
1 1/4 1 1/4
in
–
–
–
–
–
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2
–
2
1 1/2 1 1/2 1 1/2
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
2
–
–
–
–
–
–
2
2
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
2
–
–
–
–
–
––
–
2 1/2 2 1/2 2 1/2 2 1/2
2 1/2 2 1/2
–
2 1/2
2 1/2
3
2 1/2 2 1/2 2 1/2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3
3
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3 1/2 3 1/2 3 1/2
–
3 1/2
4
–
–
–
–
–
–
–
–
4
–
HUB
PUNCHING
HUB
HUB
HUB
PUNCHING
PUNCHING PUNCHING
Dimensions (in inches)
Box No.
Width
Height
Depth
R25
R26
R27
R28
R29
R30
R31
R32
R32A
R40
14
26
4 1/2
6 3/16
6 3/16
6 1/4
6 1/4
6 3/16
6 3/16
5
14 9/16
14 9/16
22 1/2
22 1/2
14 9/16
14 9/16
16
43 5/8
48 1/8
27 7/8
34 7/8
40 1/2
33 9/16
17
Z
Z
Z
18 7/8
14
18 9/16
32
5
B
B
B
B
B
B
B
4 1/2
1/4"
C
B
B
Z
B
B
K
S
S
S
B
Box R26, R27
Box R25
B
R
B
BB
C
BB
A
B
L
B
EE
EE
B
BB
BB
G
G
C
B
B
B
B
C
B
B
B
B
B
C
BB
C
BB
B
C
B
B
Box R28
Box R29
Box R30
HUB
PUNCHING
HUB
PUNCHING
R
A
B
L
C
G
G
B
FF
FF
C
B
P
P
Box R31
B
A
B
A
B
FF
B
FF
HUB
Box R32
Box R32A
9/32
CC CC
CC
EE
E
EE
GG
Box R40
BuyLog™ Catalog
Rev. 11/13
1-40
Data subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Circuit Breakers
Meter Socket Load Centers
Knockouts
Symbol
A
•
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
EE
FF
GG
5/32
–
3/8
1/2
–
–
–
–
3/8
1/2
3/4
–
–
–
–
–
–
3/8
1/2
3/4
1
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
1
–
–
–
–
–
–
1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1/2
–
1/2
3/4
–
–
1/2
3/4
1
1/2
3/4
1
–
–
–
–
1/2
3/4
–
–
–
1/2
3/4
–
–
–
1/2
3/4
1
1/2
–
1/2
3/4
1
3/4
–
3/4
1
3/4
1
3/4
–
3/4
1
3/4
1
3/4
1
–
3/4
1
Conduit
Size
–
–
–
–
–
–
–
–
–
1 1/4
1 1/2
–
–
1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4
1 1/4 1 1/4
–
1 1/4 1 1/4 1 1/4
1 1/2 1 1/2 1 1/2
–
1 1/4 1 1/4
–
1 1/4 1 1/4 1 1/4
in
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2
–
2
1 1/2 1 1/2 1 1/2
–
–
–
–
–
–
–
1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
2
–
–
–
–
–
–
2
2
–
–
–
–
2
–
–
–
–
2
–
–
–
–
2
2
2
2
–
–
–
–
–
–
–
––
–
2 1/2 2 1/2 2 1/2 2 1/2
2 1/2 2 1/2
–
2 1/2
2 1/2
3
2 1/2 2 1/2 2 1/2 2 1/2
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
3
3
–
–
–
–
–
–
–
–
–
–
–
–
–
3
–
–
–
–
–
–
–
–
–
–
3 1/2 3 1/2 3 1/2
–
3 1/2
4
–
–
–
–
–
–
–
–
–
–
4
–
Dimensions (in inches)
Box No.
Width
Height
Depth
R33
R34
R35
R36
R37
R38
R39
R40
30 1/4
30 1/4
30 1/4
14
14
14
33
40
47
28 1/2
31 3/4
49 1/2
31 11/16
32
6 3/32
6 3/32
6 3/32
4 1/2
4 1/2
10
S
S
Z
S
S
S
Z
S
14
14
4 5/8
4 1/2
3/32
3/32
3/32
3/32
3/32
K
K
D
K
D
K
K
K
R
R
D
R
R
D
G
D
AA
AA
D
G
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
Box R34, R35
Box R33
HUB
HUB
HUB
HUB
9/32
9/32
CC CC
CC
CC CC
CC
B
B
D
D
D
B
B
L
L
G
EE
EE
EE
E
E
D
D
D
D
D
W
G
GG
GG
Box R38
Box R36A, R37A
Box R36B, R37B
HUB
EE
EE
C
C
C
C
C
C
EE
EE
9/32
CC CC
CC
9/32
C
C
C
C
C
C
K
EE
C
C
C
EE
EE
E
C
GG
C
C
Box R39
Box R40
BuyLog™ Catalog
Rev. 11/13
1-41
Data subject to change
without notice