ZISS420DRSS – GE Monogram 42" Built-In Stainless Steel Side-by-Side
Refrigerator with Dispenser and Water Filter
The Installation Space
* Shipping height.
41"
Case Width
36" Models 12"
42" Models 18"
48" Models 20"
25-3/4"
The refrigerator
can be adjusted to
fit into a cutout that
is 83-1/2" min. to
84-1/2” max. height.
Note that the top
case trim at the
*Finished Width
*84" From
Floor to
Top Frame
6"
*83-1/2"
at
Rear
Electrical
Area
front is 1/2" higher
and will overlap
84-1/2" max
83-1/2" min
Finished
5"
upper cabinetry or
soffit. Use leveling
legs and wheels for
a maximum 1" height
adjustment.
75" From Floor
to Bottom
of Electrical
Area
Opening
24"
5"
42"
27-3/4"
Frame to Frame
5"
including
Water Supply
3-1/2"
handle
Product Clearances
3-1/2"
Water And Electrical Locations
These refrigerators are equipped with a 2 position door stop.
The factory set 130° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
The opening must be prepared with the electrical and water
supply located as shown.
90° Door Swing
130° Door Swing
13"
19"
The cutout depth must be 24".
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
23-7/8"
Behind
Frame
The cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
26-5/8"
Frameless cabinets:
4" Min.
to Wall
The case trim overlaps cabinets at the top and sides.
Therefore, frameless cabinets may require filler strips to
prevent interference with cabinet door swing. The opening
must allow for filler strips.
Allow minimum clearances for freezer door and fresh food
door for a full 130° door swing and to allow for pan removal.
4" minimum clearance is required when door swing is adjusted
to 90°. If the 90° door stop position is used, pan access is
maintained, but pan removal is restricted.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
Installation Information: Before installing, consult
installation instructions packed with product, or online
at Monogram.com, for current dimensional data.
As an EnErgy StAr®
Note: GFI (ground fault interrupter) is not recommended.
partner, gE has determined
that this product meets the
EnErgy StAr guidelines
for energy efficiency.
Listed by
Underwriters
Laboratories
• Water line can enter the opening through the floor or back
wall. The water line should be 1/4" O.D. copper tubing or
GE SmartConnect™ kit between the cold water line and water
connection location, long enough to extend to the front of the
refrigerator. Installation of an easily accessible shut off valve
in the water line is recommended.
For answers to your Monogram, gE Profile™ or
gE® appliance questions, visit our website at
gEAppliances.com or call
®
Specification Revised 3/08
gE Answer Center® service, 800.626.2000.
110187
Download from Www.Somanuals.com. All Manuals Search And Download.
|