		 GE Appliances   
					AZ28E09D – GE Zoneline® Deluxe Series Cooling and Electric Heat Unit   
					Wall Case Dimensions   
					Maximum Cord Extension (in inches)   
					Electrical Wiring   
					All wiring, including installation of receptacle, must be made in   
					accordance with local electrical codes and regulations.   
					A 
					Note: Aluminum wiring may pose special problems – consult   
					a qualified electrician.   
					Grille Options   
					Stamped Aluminum Grille – RAG60   
					Exterior Architectural Louvers Durable Polycarbonate:   
					C 
					RAG61 or RAG64 (Beige)   
					RAG63 or RAG66 (Bittersweet)   
					21   
					58   
					RAG62 or RAG65 (Maple) RAG67 (Extruded Aluminum)   
					Retrofit Kits:   
					B 
					RAK901L – Wall Case Insulation for use with heat pumps.   
					RAK40 – Deflector Kit to adapt chassis for use with existing   
					exterior architectural louvered grilles.   
					RAB71 Wall Sleeve   
					Wall Opening Dimensions   
					Heavy-gauge galvanized steel, with insulation.   
					A – 42", B – 13-3/4", C – 16"   
					Add 1/4" to A and C dimensions for all cut-out size.   
					RAB71 16-1/4" Min. H x 42-1/4" Min. W   
					Ducted Applications   
					2800 and 3800 series can be used with ductwork to heat or   
					cool more than one room. RAK6052 Duct Adaptor is applied   
					to top of case over air discharge/RAK601 Duct Extension is   
					applied to right or left of adaptor. Locally fabricated ductwork   
					may be added to extend to maximum recommended distance   
					of 15 feet.   
					RAB71 available in 16", 24", 28" and 31" depths   
					RAB77 16-1/2" Min. H x 42-3/8" Min. W   
					RAB77 Wall Sleeve   
					Molded SMC fiberglass-reinforced polyester compound.   
					A – 42-1/8", B– 13-7/8", C – 16-1/4   
					230/208 Volt Line Cord Connected Units   
					Min. Circuit   
					Protection   
					(Amps)   
					Line Cord   
					Kit   
					Electric Heat   
					(Btuh)   
					Electric   
					Heater Watts Heat Amps   
					2,550/2,090   
					3,450/2,820   
					5,000/4,090   
					Electric   
					Electrical Connection   
					230/208 volt units may be plugged into a receptacle. 265 volt   
					units are provided with a junction box and require direct   
					connection. (NEC Requires 265V Direct Connection) See   
					Architects and Engineers Design Data Manual for electrical   
					connection information including use of sub-base for direct   
					connected units. Installation must comply with local electrical   
					codes and regulations.   
					RAK3153   
					RAK3203   
					RAK3303   
					8,600/7,100   
					11,700/9,600   
					17,000/13,900   
					11.6/10.6   
					15.5/14.1   
					22.3/20.3   
					15   
					20   
					30   
					230/208 Volt Sub-Base Connected Units   
					Min. Circuit   
					Protection   
					(Amps)   
					Electric Heat   
					(Btuh)   
					Electric   
					Heater Watts Heat Amps   
					Electric   
					Power Connection kits required on all Zoneline chassis.   
					Sub-Base   
					RAK204D15P   
					RAK204D20P   
					RAK204D30P   
					8,600/7,100   
					11,700/9,600   
					17,000/13,900   
					2,550/2,090   
					3,450/2,820   
					5,000/4,090   
					11.6/10.6   
					15.5/14.1   
					22.3/20.3   
					15   
					20   
					30   