Furman Sound Power Supply AR 1215 User Manual

VOLTAGE  
REGULATORS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AR-1215 AC LINE VOLTAGE REGULATOR  
over, or stressed. Pay particular attention to  
±5V  
AR-1215  
120  
97 to 141  
97 to 141  
80 to 122  
174 to 264  
181 to 276  
190 to 288  
condition of cords and cables at plugs, and the  
point where they exit from the AR-1215 or AR-  
2306. To prevent risk of fire or injury, damaged  
cords and cables should be replaced immedi-  
ately.  
±5V  
AR-1215J 120  
AR-1215J 100  
±4V  
±10V  
±10V  
±10V  
AR-2306  
AR-2306  
AR-2306  
220  
230  
240  
5. Clean theAR-1215 orAR-2306 with a damp cloth  
only. Do not use solvents or abrasive cleaners.  
Never pour any liquid on or into the unit.  
NOTE: The three models in the AR-Series differ in  
their nominal AC output voltages. Model AR-1215  
produces 120 VAC. Model AR-1215J produces  
either 100 or 120 VAC. Model AR-2306 produces  
either 220, 230, or 240 VAC.  
6. When left unused for a long period of time, the  
power cord of the AR-1215 or AR-2306 should  
be unplugged from the outlet.  
Where differences exist between models, informa-  
tion applicable to the AR-2306 is shown in the text of  
this manual in brackets [ ].  
7. The AR-1215 or AR-2306 should be serviced  
by qualified service personnel when:  
a. The power supply cord or the plug has been  
frayed, kinked, or cut.  
b. Objects have fallen or liquid has spilled into  
the unit.  
c. The AR-1215 or AR-2306 has been exposed to  
rain or other moisture.  
d. The AR-1215 or AR-2306 does not appear to  
operate normally or exhibits a marked change  
in performance.  
e. The AR-1215 or AR-2306 has been dropped,  
or the enclosure damaged.  
FIRST: SELECT THE CORRECT VOLT-  
AGE!  
Before using your Voltage Regulator, be sure that if  
there is an output voltage switch on the rear panel  
(just above the cord, on Models AR-1215J and  
AR-2306 only), it is correctly set for the AC voltage  
required by your equipment. Each item of equipment  
that you intend to power with the Voltage Regula-  
tor should have its required voltage indicated on it,  
usually on the rear near the cord. If in doubt, consult  
your dealer.  
8. The AR-1215 or AR-2306 requires that a safety  
ground be present for proper operation. Any  
attempt to operate the AR-1215 or AR-2306  
without a safety ground is considered improper  
operation and could invalidate the warranty.  
Furman Voltage Regulators are intended to pro-  
tect sensitive electronic equipment from problems  
caused by AC line voltage irregularities—brownouts  
or overvoltages that can cause audio tonal changes,  
digital equipment malfunction (such as loss of MIDI  
programs or other data), or, in extreme cases,  
permanent damage. They accept input voltages  
over a wide AC voltage range (see table on page 2)  
and convert them to a steady, stable output at the  
desired standard voltage, plus or minus five [ten]  
volts. Voltages approximately ±10% beyond that  
range may be converted to usable levels, depending  
on the requirements of the equipment. See graphs  
on the back page.  
9. There are no user serviceable parts in the AR-  
1215 or AR-2306. Refer servicing to qualified  
service personnel only.  
NOMINAL OUTPUT VOLTAGES VS.  
INPUT “IN-REGULATION” RANGES:  
Output  
Accu-  
racy  
Model  
Voltage In-Regula-  
Setting tion Range  
The AR-1215 has eight [AR-2306 has ten IEC-320]  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
AR-1215 AC LINE VOLTAGE REGULATOR  
convenience outlets on the rear panel, and one on  
the front panel. All are functionally interchangeable.  
The outlets are regulated, spike-suppressed, and fil-  
tered against RFI with a 3-pole filter, making the unit  
a full-function power conditioner. The AR-1215 has  
no controls except an on-off switch. (The AR-1215J  
and AR-2306 also have an output voltage selector  
switch.)  
you should plan your total load so that it does not  
exceed 12 amps, or 1400 watts. Please note that  
this refers to the aggregate power requirement of all  
equipment plugged into the Voltage Regulator, not to  
each individual item.  
The AR-2306 can handle loads totalling up to 6  
amperes as long as the input voltage is equal to  
or above the selected output voltage. For voltages  
below that level, its capacity must be derated at ap-  
proximately 23 milliamperes per volt. (Again, please  
see graphs on back page.) As a practical matter,  
therefore, to cope successfully with worst-case  
brownout conditions, you should plan your total load  
so that it does not exceed 5 amps, or 1100 watts.  
Please note that this refers to the aggregate power  
requirement of all equipment plugged into the Volt-  
age Regulator, not to each individual item.  
Note: The AR-1215 and AR-2306 are for use with  
AC voltage only. DC voltages should never be ap-  
plied to them. Also, they do not change or regulate  
line frequency. The output frequency will always be  
the same as the incoming frequency.  
MAXIMUM AND MINIMUM LOAD  
The AR-1215 and AR-1215J can handle loads total-  
ling up to 15 amperes as long as the input voltage  
is equal to or above 124 volts (or 104 volts if using  
AR-1215J set to 100 volt output). For voltages below  
that level, its capacity must be derated at approxi-  
mately 113 milliamperes per volt. (See graphs on  
back page.) As a practical matter, therefore, to cope  
successfully with worst-case brownout conditions,  
NOTE: While there is no minimum load require-  
ment for the AR1215 or AR-2306, you may  
experience an audible mechanical hum coming  
directly from the unit when the POWER switch  
is on with nothing plugged in. This effect will  
disappear as soon as you plug in any equipment  
15A 120V 50-60HZ�  
ON�  
EXTREME �  
VOLTAG�E�  
INPUT VOLTAGE�  
IN�  
A.C. LINE VOLTAGE�  
REGULATOR�  
REGULATION� SHUTDOWN �  
75-98�101� 105� 110� 115� 120� 125� 131� 137� 140-150�  
MODEL AR-1215  
OFF�  
REGULATED OUTLET�  
POWER�  
AR-1215 front view  
REGULATED�  
OUTPUTS�  
120 VAC�  
15 AMP�  
W�  
100  
V� 120 V�  
A�  
R�  
N�  
I�  
N�  
G�  
15�  
A�  
M�  
P�  
75-140 VAC�  
15 AMPS�  
FOR CONTINUED  
DISCONNECT SUPPLY  
BEFORE CHANGING FUSE.�  
COUPER L'ALIMENTATION  
AVANT DE CHANGER LE FUSIBL�  
PROTECTION AGAINST�  
FIRE HAZARD REPLACE�  
WITH SAME TYPE AND�  
RATING OF FUSE�  
ATTENTION:�  
REMPLACER LE FUSIBL�  
AVEC MEME TYPE�  
E�  
E�  
AR-1215J rear view (the switch above the AC cord is not present in the AR-1215)  
220� 230� 240�  
N’OUVREZ PAS—RISQUE�  
DE CHOC ELECTRIQUE�  
CIRCUIT�  
BREAKER�  
174-288 VAC  
6
A�  
OUTPUT VOLTAGE�  
6�  
A�  
M�  
P�  
AR-2306 rear view. NOTE: The three models in the AR-Series differ in their nominal AC output voltages. Model AR-1215  
produces 120 VAC: AR-1215J produces either 100 or 120 VAC; and AR-2306 produces either 220, 230, or 240 VAC.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
AR-1215 AC LINE VOLTAGE REGULATOR  
Because noise occurs at higher frequencies than  
the 50 or 60 Hz AC line, it can be effectively reduced  
through use of low-pass filtering.  
drawing 40 to 50 watts total.  
DEFINITIONS  
VOLTAGE REGULATION: The AC line voltage is a  
number indicating the nominal electrical potential  
that has been adopted in a region for powering  
electrical equipment of all kinds. In most of North  
America it is 117 volts AC; in Japan, 100 volts; and  
in many other countries 220, 230, or 240 volts. The  
actual voltage can fall below or rise above this nomi-  
nal level due to brownouts, power cutbacks, use of  
substandard wiring, and other causes. These devia-  
tions can cause poor performance or a malfunction.  
A regulator is a device which, through use of a trans-  
former, corrects the voltage deviation by stepping it  
up or down so that it is as close as possible to the  
nominal level.  
EXTREME VOLTAGE PROTECTION  
The AR-Series includes special circuitry to sense  
over- and under-voltages and positively shut down  
the output before possible damage is done. See  
the Specifications on the back page for the exact  
voltages at which shutdown occurs. When the input  
voltage exceeds the limit, the power will cut off. It will  
come back on automatically when the overvoltage  
is removed as long as the voltage has not exceeded  
300V [all models]. The red LED labelled EXTREME  
VOLTAGE SHUTDOWN indicates the shutdown  
condition. The output is also shut down for extremely  
low input voltages.  
To provide protection against a catastrophic error in  
AC mains wiring, dangerously high voltages (those  
over approximately 300V) will cause an internal fuse  
to blow, but equipment plugged into the Voltage  
Regulator will not be damaged.  
SPIKE: A pulse of energy on the power line. Spikes  
can have voltages as high as 6000 volts. Though  
they are usually of very short duration, the energy  
they contain can be considerable, enough to dam-  
age sensitive solid-state components in audio and  
computer equipment. Spikes can also foul switch  
contacts and degrade wiring insulation. They are  
an unavoidable component of electric power. They  
are caused unpredictably by electric motors switch-  
ing on or off (on the premises or outside), utility  
company maintenance operations, nearby lightning  
strikes, and other factors. Spikes (also called surges  
or transients) are absorbed by special components  
called MOV’s in the AR-series to provide safe volt-  
age levels to protect your equipment.  
FUSES AND CIRCUIT BREAKERS  
There is one fuse and one circuit breaker in the  
AR-Series. In the event that the unit appears to  
be completely dead (neither the Power switch nor  
any LED’s light up), unplug the power cord and the  
load and check the breaker. If the circuit breaker is  
tripped, a white button will pop up. Push it back in  
to reset it. The purposes of these circuit protection  
devices are:  
RFI/EMI INTERFERENCE: Noise from RFI (Radio  
Frequency Interference) or EMI (Electro Magnetic  
Interference) involves lower voltages and less  
energy than is found in spikes, but it is continuous  
rather than transient in nature. It is not likely to cause  
physical damage, but it can certainly be annoying,  
producing static in audio circuits, “snow” on video  
screens, or garbled data in computers. Noise can be  
introduced into AC lines by nearby radio transmitters,  
certain kinds of lighting, electric motors, and others.  
1. A fast-blow 15 amp [6 amp] circuit breaker is  
accessible at the rear panel without removing  
the unit from the rack. This breaker will trip if the  
unit’s 15 amp [6 amp] capacity is exceeded at  
any time.  
2. A fast-blow 1/4 amp fuse is located inside the  
unit. This fuse will blow if the unit has been  
connected to a voltage that is above the range  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
AR-1215 AC LINE VOLTAGE REGULATOR  
It offers a 20-LED bargraph line voltage meter to moni-  
tor the incoming line (the Voltage Regulator output),  
twin slide-out, swiveling lights with a dimmer control  
for equipment illumination, and eight [ten] additional  
outlets with their own spike and surge protection and  
RFI / EMI filtering.  
of the Extreme Voltage Shutdown circuitry  
(approximately 200 VAC for AR-1215 and AR-  
1215J; approximately 400 VAC for AR-2306). To  
replace it, the unit must be completely discon-  
nected from all power and removed from its rack.  
The six hex head screws and one Phillips head  
screw holding the top cover must be removed.  
The internal fuse is located in a holder on the  
printed circuit board. Replace the fuse only with  
the exact same type (1/4 fast blow).  
INSTALLATION  
Because of their toroidal transformer design, Fur-  
man Voltage Regulators may be positioned near  
most other equipment without fear that the other  
equipment will be disrupted by leakage of a strong  
50/60 Hz magnetic field. Nevertheless, suggested  
rack locations would be either at the top or bottom.  
INPUT VOLTAGE MONITORING  
The row of ten LED’s at the left of the front panel  
make up a meter that indicates INPUT VOLTAGE.  
Only one LED will light up at a time. There are two  
red LED’s at the endpoints. When lit, they indicate  
that the input voltage may be above or below the  
point where it can be restored to the selected nominal  
output voltage (though it may still be restored to a us-  
able level) but is not high or low enough to cause an  
extreme voltage shutdown.  
As with any rackmount equipment, be sure to use  
10-32 machine screws for mounting in the rack’s  
tapped holes (this is not a metric size). In particular,  
beware of 10-24 screws, which may fit if forced but  
which will strip the threads. To avoid marring the  
front panel finish, use plastic washers under the  
screw heads.  
The AR-1215J and AR-2306, which have switchable  
output voltages, also have multiple scales on the  
Input Voltage meter corresponding to the selected  
voltage. On the AR-2306, there are three scales,  
with the top for 220V, the middle for 230V, and the  
bottom for 240V.  
DESIGN  
The AR-Series uses a design based on an eight-tap  
toroidal autoformer. The toroidal design assures  
minimal leakage of stray magnetic fields, and, be-  
cause of its high efficiency, a very compact size for  
its rating. The Voltage Regulator’s circuitry monitors  
the incoming line voltage with each cycle, comparing  
it to an extremely precise voltage reference, accurate  
to ±0.15%. If a voltage fluctuation requires that a  
different tap be selected, the new tap is electronically  
switched exactly at the zero-crossing, to avoid dis-  
torting the AC waveform. If necessary, it can switch  
taps as often as once each cycle. Most commercial  
voltage regulators using multiple-tapped trans-  
formers switch taps at uncontrolled times, thereby  
creating voltage spikes and clicks that can leak into  
the audio! Hysteresis in the switching circuits avoids  
“chatter” or unnecessary switching back and forth be-  
tween adjacent taps. Unlike those voltage regulators  
that employ ferro-resonant transformers, Furman  
Voltage Regulators are not sensitive to small errors  
OUTPUT VOLTAGE MONITORING  
A green LED labelled OUTPUT IN REGULATION  
indicates proper function (i.e., that the output voltage is  
within ±5V [±10V] of the selected output voltage). Your  
equipment will always work normally when this light is  
on, and often will work satisfactorily even when it is off.  
If you wish to monitor your AR-1215’s output volt-  
age more precisely, you may want to use a Furman  
PL-PLUS Power Conditioner and Light Module  
in conjunction with it [use model PL-PLUS-E with  
model AR-2306].  
The PL-PLUS is the perfect complement to a Furman  
Voltage Regulator to assist in rack power distribution.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
AR-1215 AC LINE VOLTAGE REGULATOR  
in line frequency, making them ideal for use with  
generators.  
damages resulting from such non-Manufacturer  
made products or components. This warranty shall be  
cancelable by Manufacturer at its sole discretion if the  
product is modified in any way without written autho-  
rization from Furman Sound. This warranty also does  
not apply to Products upon which repairs have been  
affected or attempted by persons other than pursuant  
to written authorization by Manufacturer.  
ONE LIMITED WARRANTY  
Furman Sound, Inc., having its principal place of  
business at 1997 South McDowell Blvd., Petaluma,  
CA 94954 (“Manufacturer”) warrants its AR-1215 /  
AR-2306 (the “Product”) as follows:  
THIS WARRANTY IS EXCLUSIVE. The sole and  
exclusive obligation of Manufacturer shall be to repair  
or replace the defective Product in the manner and  
for the period provided above. Manufacturer shall not  
have any other obligation with respect to the Products  
or any part thereof, whether based on contract, tort,  
strict liability or otherwise. Under no circumstances,  
whether based on this Limited Warranty or otherwise,  
shall Manufacturer be liable for incidental, special, or  
consequential damages. Manufacturer’s employees  
or representatives’ ORAL OR OTHER WRITTEN  
STATEMENTS DO NOT CONSTITUTE WARRAN-  
TIES, shall not be relied upon by Purchaser, and  
are not a part of the contract for sale or this limited  
warranty. This Limited Warranty states the entire obli-  
gation of Manufacturer with respect to the Product. If  
any part of this Limited Warranty is determined to be  
void or illegal, the remainder shall remain in full force  
and effect.  
Manufacturer warrants to the original Purchaser of  
the Product that the Product sold hereunder will be  
free from defects in material and workmanship for a  
period of one year from the date of purchase. The  
Purchaser of the product is allowed fifteen days from  
the date of purchase to complete warranty registra-  
tion by mail or on-line at the Furman website. If the  
Product does not conform to this Limited Warranty  
during the warranty period (as herein above speci-  
fied), Purchaser shall notify Manufacturer in writing  
of the claimed defects. If the defects are of such  
type and nature as to be covered by this warranty,  
Manufacturer shall authorize Purchaser to return the  
Product to the Furman factory or to an authorized  
Furman repair location. Warranty claims should be  
accompanied by a copy of the original purchase  
invoice showing the purchase date; this is not neces-  
sary if the Warranty Registration was completed ei-  
ther via the mailed in warranty card or on-line website  
registration. Shipping charges to the Furman factory  
or to an authorized repair location must be prepaid by  
the Purchaser of the product. Manufacturer shall, at  
its own expense, furnish a replacement Product or, at  
Manufacturer’s option, repair the defective Product.  
Return shipping charges back to Purchaser will be  
paid by Manufacturer.  
SERVICE  
Before returning any equipment for repair, please  
be sure that it is adequately packed and cushioned  
against damage in shipment, and that it is insured.  
We suggest that you save the original packaging  
and use it to ship the product for servicing. Also,  
please enclose a note giving your name, address,  
phone number and a description of the problem.  
THE FOREGOING IS IN LIEU OF ALL OTHER WAR-  
RANTIES, EXPRESS OR IMPLIED, INCLUDING  
BUT NOT LIMITED TO THE IMPLIED WARRAN-  
TIES OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE. Manufacturer does not  
warrant against damages or defects arising out of  
improper or abnormal use of handling of the Product;  
against defects or damages arising from improper  
installation, against defects in products or compo-  
nents not manufactured by Manufacturer, or against  
NOTE: All equipment being returned for repair must  
have a Return Authorization (RA) Number. To get an  
RA Number, please call the Furman Service Depart-  
ment, (707) 763-1010, ext. 120 or 121, between 8  
a.m. and 5 p.m. U.S. Pacific Time, or fax to (707)  
763-1310. Please display your RA Number promi-  
nently on the front of all packages.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spike Protection Modes:  
Line to neutral, neutral to ground, line to ground.  
SPECIFICATIONS  
Output Current Rating:  
Spike Clamping Voltage:  
AR-1215: 15 amperes for input voltages of 124V  
(104V for AR-1215J in 100V mode) or higher;  
derate at 113 mA per volt to a minimum of 12.3A.  
AR-1215/AR-1215J: Initial turn-on at 200V; TVSS rating  
of 400 volts peak at 500 A, L-N, N-G, L-G (tested to UL-  
1449).  
AR-2306: 6 amperes for input voltages of 228V/238V/248V  
(depending on Output Voltage switch setting) or higher;  
derate at 23 mAper volt to a minimum of 4.9A.  
AR-2306: Initial turn-on at 390 volts peak L-N; 680 volts  
peak N-G, L-G.  
Response time:  
1 nanosecond.  
“In Regulation” Ranges:  
AR-1215 (and AR-1215J set to 120V):  
provides regulation ±5V from 97V to 141V.  
Maximum surge current:  
6,500 amps.  
AR-1215J (set to 100V): provides regulation ±4V from  
82V to 115V.  
Maximum spike energy:  
AR-1215/AR-1215J: 80 joules per node;  
240 joules total.  
AR-2306: provides regulation ±10V in the following ranges:  
174-264V (220 mode), 181-276V (230 mode), 190-288V  
(240 mode).  
AR-2306: 130 joules L-N, 160 joules N-G, L-G,  
450 joules total.  
Shutdown Range:  
AR-1215 (and AR-1215J set to 120V): Below 75V or  
above 150V.  
Noise attenuation:  
Transverse and common modes: 20 dB at 200 kHz, rising  
to >40 dB, 1 to 100 MHz.  
AR-1215J: (set at 100V): Below 65V or above 135V.  
Dimensions:  
1.75” H x 19” W x 8.5” D.  
AR-2306: Below 146V or above 279V (220 mode); Below  
152V or above 287V (230 mode), Below 158V or above  
300V (240 mode).  
Weight:  
12 lbs. (5.5 kg)  
Voltmeter Accuracy:  
AR-1215 (and AR-1215J set to 120V): ±5V.  
AR-1215J (set to 100V) : ±4V.  
AR-2306: ±10V.  
Furman Sound, Inc. • 1997 South McDowell Blvd. • Petaluma, CA 94954-6919 USA  
Made in China  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Chainsaw CS 280E User Manual
Eclipse Fujitsu Ten Car Stereo System CD5444 User Manual
Essick Air Humidifier EP9 500 User Manual
Extron electronic TV Cables 26 681 06 User Manual
Fostex Car Speaker FT7RP User Manual
Foundry Networks Switch M2404C User Manual
FujiFilm Camcorder 16109884 User Manual
GE DVD Player DGE100N User Manual
GE Microwave Oven 164D2966P142 User Manual
GE Monogram Cooktop Component Cooktop System User Manual