Fujitsu Scanner fi 6010N User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Contents  
3.3 Setting the Scanner Name ................................................. 7  
3.4 Setting the Region/Timezone ............................................ 8  
3.5 Setting the IP Address/DHCP ............................................ 8  
3.6 Setting the Admin Network................................................ 9  
3.7 Setting the DNS Server .................................................... 10  
3.8 Setting the WINS Server................................................... 10  
3.9 Checking the Network Connection ................................. 11  
3.10 Restarting the System..................................................... 11  
Introduction ................................................................................. iii  
Manuals ........................................................................................... iii  
Regulatory Information ................................................................. iii  
Note of Liability ...............................................................................iv  
Trademarks ......................................................................................iv  
Important Notes ................................................................................v  
Safety Precautions ...........................................................................vi  
Chapter 1 Scanner Features.................................................... 1  
1.1 Scanner Features................................................................1  
1.2 Logging In............................................................................2  
1.3 From Arrival through Operation........................................2  
1.4 Checking the Contents of the Scanner Package .............2  
1.5 Names and Functions of Parts ..........................................3  
Chapter 4 Installing the Admin Tool .....................................12  
Chapter 5 Downloading the Manual......................................14  
Chapter 6 Performing a Scan Test ........................................15  
Appendix A Calibrating the Touch Panel.................................18  
Appendix B Scanner Care .........................................................19  
Appendix C Replacing Parts .....................................................21  
Appendix D Network Connection Troubleshooting................23  
Appendix E Troubleshooting....................................................27  
Copyright ....................................................................................29  
Chapter 2 Setting up the Scanner........................................... 4  
2.1 Space Requirements ..........................................................4  
2.2 Installing the Scanner.........................................................4  
2.3 Connecting the Cables.......................................................4  
2.4 Attaching the Keyboard Cover ..........................................5  
Chapter 3 Setting up for Network Use.................................... 6  
3.1 Logging in............................................................................6  
3.2 Changing the Administrator Password ............................7  
i
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Introduction  
Do not breathe the chemical liquid contained in  
the scanner lamps.  
Note of Liability  
Do not incinerate, crush, or shred the lamps or  
Thank you for purchasing the fi-6010N Network  
Scanner.  
This easy-to-operate network scanner is used to scan  
documents for further use.  
encouraged to try to correct the interference by  
one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
BEFORE USING THIS PRODUCT, PLEASE  
READ THIS MANUAL CAREFULLY. IF THIS  
PRODUCT IS NOT USED CORRECTLY,  
UNEXPECTED INJURY CAN OCCUR TO  
USERS OR BYSTANDERS.  
scanner parts.  
LCD Peculiarities  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
located.  
Consult your dealer or an experienced radio/TV  
technician.  
The LCD backlight is a fluorescent tube that  
contains some mercury.  
Be aware that neither of the following is  
considered a fault.  
Keep this manual in a safe place so that it can be  
easily referred to during use of this product.  
Manuals  
While all efforts have been made to ensure the  
accuracy of all information in this manual, PFU  
assumes no liability to any party for any damage  
caused by errors or omissions or by statements of  
any kind in this manual, its updates or  
supplements, whether such errors are omissions or  
statements resulting from negligence, accidents,  
or any other cause. PFU further assumes no  
liability arising from the application or use of any  
product or system described herein; nor any  
liability for incidental or consequential damages  
arising from the use of this manual. PFU disclaims  
all warranties regarding the information contained  
herein, whether expressed, implied, or statutory.  
The following manuals are prepared for the  
scanner. Read them as needed.  
Despite the advanced technologies used  
to produce the devices TFT color  
LCD's, the large number of pixels  
involved means that an occasional  
(always-on) bright dot or (always-off)  
dark dot may be visible.  
FCC warning: Changes or modifications not  
expressly approved by the party responsible for  
compliance could void the user’s authority to  
operate the equipment.  
Manual  
Description  
fi-6010N Net-  
work Scanner  
Provides useful and detailed  
information on setting up,  
The characteristics of the LCD mean  
that there may be some variation in hue  
and intensity of colors across the screen.  
Getting Started connecting, and caring for  
The use of a shielded interface cable  
ATTENTION  
is required to comply with the Class B  
limits of Part 15 of FCC rules.  
The length of the AC cable must be 2  
meters (6.6 feet) or less.  
(This Manual)  
(paper)  
your scanner.  
Read this manual first.  
fi-6010N Net-  
work Scanner  
Operator's  
Contains further information  
about scanner settings, scan-  
ner administration, and scan-  
ner operations, and may be  
used as a general reference.  
To read the manual, down-  
load it from the scanner. For  
more details about how to  
download the manual, refer  
to "Chapter 5 Downloading  
the Manual" (page14)  
Replacing Batteries  
Use in High-safety Applications  
This product has a battery (CMOS RAM battery)  
on board to retain data such as  
Warning  
Canadian DOC Regulations  
Guide (PDF)  
This product has been designed and manufactured  
on the assumption that it will be used in office,  
personal, domestic, regular industrial, and  
general-purpose applications. It has not been  
designed and manufactured for use in applications  
(simply called "high-safety applications" from  
here on) that directly involve danger to life and  
health when a high degree of safety is required,  
for example, in the control of nuclear reactions at  
nuclear power facilities, automatic flight control  
of aircraft, air traffic control, operation control in  
mass-transport systems, medical equipment for  
sustaining life, and missile firing control in  
weapons systems, and when provisionally the  
safety in question is not ensured. The user should  
use this product with adopting measures for  
ensuring safety in such high-safety applications.  
PFU LIMITED assumes no liability whatsoever  
for damages arising from use of this product by  
the user in high-safety applications, and for any  
claims or compensation for damages by the user  
or a third party.  
Do not replace the battery yourself, as  
there is a risk of explosion if the wrong  
type is used. Please contact your main-  
tenance engineer in charge when the  
battery runs low.  
This digital apparatus does not exceed the Class B  
limit for radio noise emissions from digital  
apparatus set out in the Radio interference  
Regulations of the Canadian Department of  
Communications.  
This Class B digital apparatus complies with  
Canadian ICES-003.  
Do not touch the battery. Never install  
or remove the battery by yourself.  
Doing so may cause electric shock or  
static electricity which can damage the  
device.  
Le présent appareil numérique n'émet pas de  
parasites radioélectriques dépassant les limites  
applicables aux appareils numériques de la classe  
B et prescrites dans le Règlement sur le brouillage  
radioélectrique dictées par le Ministère des  
Communications du Canada.  
In this guide, it is indicated  
as "Operator's Guide".  
About Maintenance  
Regulatory Information  
Cet appareil numérique de la classe B est  
conforme _ la norme NMB-003 du Canada.  
The user must not perform repairs on this scanner.  
Contact your FUJITSU scanner dealer or an  
authorized FUJITSU scanner service provider for  
repairs to this product.  
FCC Declaration  
Bescheinigung des Herstellers /  
Importeurs  
This equipment has been tested and found to  
comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference in a  
residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and,  
if not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. However,  
there is no guarantee that interference will not  
occur in a particular installation. If this equipment  
does cause harmful interference to radio or  
television reception, which can be determined by  
turning the equipment off and on, the user is  
Trademarks  
Für den fi-6010N wird folgendes bescheinigt:  
About the Use of Mercury  
Microsoft, Windows, and Windows Vista are  
registered trademarks of Microsoft Corporation in  
the United States and/or other countries.  
Adobe, the Adobe logo, and Acrobat are either  
registered trademarks of Adobe Systems  
Incorporated in the United States and/or other  
countries.  
In Übereinsstimmung mit den Bestimmungen  
der EN45014(CE) funkentstört  
Maschinenlärminformationsverordnung 3.  
GPSGV: Der höchste Schalldruckpegel beträgt  
70 dB (A) oder weniger, gemäß EN ISO 7779.  
Lamp(s) inside this product contain  
mercury and must be recycled or  
disposed of according to local, state,  
or federal laws.  
g
H
To avoid unexpected injuries:  
Do not lick or consume the substance contained  
in the lamp.  
ABBYYTM FineReaderTM 7.x Engine © ABBYY  
Software House 2005.  
iii  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
OCR by ABBYY Software House. All rights  
reserved.  
ABBYY, FineReader are trademarks of ABBYY  
Software House.  
Other product names are the trademarks or  
registered trademarks of the respective companies.  
Warning Label  
Manufacturer  
Use this scanner only at the indicated  
power voltage. Do not connect to  
multiple-power strips.  
PFU LIMITED  
International Sales Dept., Imaging Business  
Division, Products Group  
Solid Square East Tower, 580 Horikawa-cho,  
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,  
Japan  
The glass scanner windows inside the ADF  
can become hot when the scanner is used.  
Be careful not to touch the surface of the  
glass scanner windows.  
Use this scanner only at the indicated  
power voltage and current. Improper power  
voltage and current might cause fire or  
electric shock. Do not connect to multiple-  
power strips.  
How Trademarks are Indicated in  
This Manual  
Phone: (81-44) 540-4538  
Do NOT remove from the scanner,  
stain or scratch the warning labels.  
ATTENTION  
All Rights Reserved, Copyright© PFU LIMITED 2008.  
References to operating systems (OS) and  
applications are indicated as follows:  
Do not touch the AC cable with wet  
hands.  
Important Notes  
Windows  
Microsoft® Windows® operating  
Screen Examples in This Manual  
system  
Do not touch the power plug with wet  
hands. Doing so might cause electric shock.  
Warning Indications Used in This  
Manual  
The screen examples in this manual are subject to  
change without notice in the interest of product  
improvement. If the actual displayed screen  
differs from the screen examples in this manual,  
operate by following the actual displayed screen  
while referring to the User's Manual of the scanner  
application you are using.  
Windows® XP  
Microsoft® Windows® XP Pro-  
fessional operating system,  
Microsoft® Windows® XP Home  
Edition operating system  
This indication alerts operators  
to an operation that, if not strictly  
observed, may result in severe  
injury or death.  
Wipe any dust from the power plug.  
Wipe off any dust from metal parts on the  
power plug or metal fittings with a soft, dry  
cloth. Accumulated dust might cause fire or  
electric shock.  
Windows  
Vista®  
Microsoft® Windows Vista®  
The screen examples shown in this manual are  
Windows Vista® windows.  
Home Basic operating system,  
This indication alerts operators to  
an operation that, if not strictly  
observed, may result in safety  
hazards to personnel or damage  
to equipment.  
Microsoft® Windows Vista®  
Home Premium operating system,  
Microsoft® Windows Vista®  
Business operating system,  
Microsoft® Windows Vista®  
Enterprise operating system,  
Microsoft® Windows Vista® Ulti-  
mate operating system  
Safety Precautions  
Do not install the device in locations that  
has oil smoke, steam, humidity, and dust.  
Do not install the scanner in locations  
subject to oil smoke, steam, humidity, and  
dust. Doing so might cause a fire or electric  
shock.  
Symbols Used in This Manual  
Do not damage the AC cable.  
This symbol alerts operators to partic-  
ATTENTION  
A damaged AC cable may cause fire or  
electric shock. Do not place heavy objects  
on AC cables, or pull, bend, twist, heat,  
damage or modify AC cables.  
Do not use damaged AC cables or power  
plugs, or install any cables or power plugs  
to loose wall sockets.  
Windows  
Microsoft® Windows Server®  
ularly important information. Be sure  
to read this information.  
Turn the scanner OFF if it is damaged.  
Server® 2003  
2003, Standard Edition  
If the scanner is damaged for any reason,  
turn the scanner off and unplug the power  
cable. Contact your FUJITSU scanner  
dealer or an authorized FUJITSU scanner  
service provider.  
Microsoft® Windows Server®  
2003, Enterprise Edition  
Microsoft® Windows Server®  
2003, Datacenter Edition  
This symbol alerts operators to helpful  
HINT  
advice regarding operation.  
Windows  
Server® 2008  
Microsoft® Windows Server®  
Use only specified AC cables and  
connector cables.  
Do not put liquids inside the scanner.  
2008 Standard  
Do not insert or drop metal objects in to the  
scanner. Do not scan wet documents or  
documents with paper clips or staples. Do  
not splash or allow the scanner to get wet.  
Microsoft® Windows Server®  
2008 Enterprise  
A TRIANGLE symbol indicates that special  
care and attention is required.  
The drawing inside the triangle shows the  
specific caution.  
Use only specified AC cables and connector  
cables. Failure to use the correct cables  
might cause electric shock and/or  
equipment failure.  
Please do not use the AC cable provided  
with this scanner for other devices, since  
this might cause equipment failure and  
other troubles or an electric shock.  
Microsoft® Windows Server®  
2008 Datacenter  
If foreign objects (water, small metal  
objects, liquids, etc.) get inside the scanner,  
immediately turn off the scanner and  
disconnect the power plug from the power  
outlet. Then, contact your FUJITSU scanner  
dealer or an authorized FUJITSU scanner  
service provider. Pay particular attention to  
this warning in households where there are  
small children.  
A CIRCLE with a diagonal line inside  
shows action which users may not perform.  
The drawing inside or under the circle  
shows the specific action that is not  
allowed.  
.NET  
Framework  
Microsoft® .NET Framework  
All the descriptions in this manual assume the  
usage of Adobe® Acrobat® bundled with this  
product. However, Adobe Acrobat may be  
upgraded without notice. If the descriptions differ  
from the screens actually displayed, refer to the  
Acrobat’s “Help”.  
Outline characters on a colored  
background show instructions users should  
follow.  
It may also include the drawing that shows  
the specific instruction.  
R
v
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Avoid any contact when scanner is in use.  
Handle documents carefully.  
Do not touch the inside of the scanner  
unless necessary.  
Do not cover the scanner with something  
during its operation.  
Avoid touching any scanner mechanism  
during scanning since this may cause  
injuries.  
When handling documents, be careful not to  
cut your fingers with them.  
Do not take apart or modify the scanner.  
The inside of the scanner contains high-  
voltage components. Touching these  
components might cause electric shock or  
fire.  
Do not use the scanner while covered with a  
blanket, etc. Doing so may raise the  
temperature inside and cause a fire.  
Do not make the scanner wet while  
carrying it outside.  
Do not use the scanner immediately after  
moving it from a cold place into a warm  
room.  
Do not use the scanner where it gets wet.  
Do not use the scanner if you smell a  
strange odor.  
When carrying the scanner outside while it  
is raining or snowing, pay special attention  
so the scanner does not get wet.  
Do not use the scanner at a place such as a  
bathroom, shower room, or swimming pool  
where it may easily get wet. Doing so might  
cause electric shock or fire.  
Do not use the device immediately after  
moving it from a cold place into a warm  
room. Condensation may occur, which  
might lead to scanning errors. Let the  
device dry about one or two hours before  
you use it.  
If you detect heat coming from the device or  
detect other problems such as smoke,  
strange smells or noises, immediately turn  
off the scanner and then disconnect its  
power plug. Make sure that any smoke  
coming from it has stopped, before  
contacting your FUJITSU scanner dealer or  
an authorized FUJITSU scanner service  
provider.  
Do not place the scanner in areas, which  
are subject to high levels of shock or  
vibration.  
Before moving the scanner, disconnect  
the power plug from the power outlet.  
Do not place the scanner in areas, which  
are subject to high levels of shock or  
vibration. Doing so may cause the scanner  
to malfunction.  
Do not install the scanner on unstable  
surfaces.  
Do not move the scanner with the power  
and interface cables connected as this can  
damage the cables, which can later cause  
fire, electric shock as well as injury.  
Before moving the scanner, be sure to  
disconnect the power plug from the power  
outlet, and all other data cables.  
Make sure that the scanner is installed on a  
flat, level surface and that none of its parts  
extend beyond the surface top, such as a  
desk or table. Do not install the scanner on  
unstable surfaces. Install the scanner on a  
level surface that is free of vibration to  
prevent it from falling.  
Install the scanner on a strong surface that  
will support the weight of the scanner and  
other devices.  
Do not use aerosol sprays near the  
scanner.  
Do not use any aerosol sprays or alcohol  
based sprays to clean the scanner.  
Dust blown up by strong air from the spray  
may enter the inside of the scanner. This  
may cause the scanner to fail or  
malfunction.  
Sparks, caused by static electricity,  
generated when blowing off dust and dirt  
from the outside of the scanner may cause  
a fire.  
Make sure that the floor is free of any  
obstructions.  
Protect the scanner from static electricity.  
Install the scanner away from strong  
magnetic fields and other sources of  
electronic noise. Also, protect the scanner  
against any static electricity, which can  
cause the scanner to malfunction.  
Do not block the ventilation ports.  
Do not block the ventilation ports. Blocking  
the ventilation ports generates heat inside  
of scanner, which may result in fire or  
scanner failure.  
Do not place the scanner within the reach  
of small children.  
To avoid injuries, do not place the scanner  
in an area where small children may be able  
to reach.  
Disconnect the power plug from the  
power outlet when the scanner is not used  
for a long period of time.  
Do not place heavy objects or climb on  
top of the scanner.  
Do not place heavy objects on the scanner  
or use the scanner's surface top to perform  
other work. Improper installation might  
cause injuries and equipment failure.  
When the scanner is not going to be used  
for a long period of time, be sure to  
disconnect the power plug from the power  
outlet for safety.  
Do not touch the heated section for a long  
time.  
Do not touch the heated section such as the  
bottom of the scanner for a long time.  
Doing so may cause a low-temperature  
burn on your skin.  
Firmly insert the power plug.  
Do not install the scanner in the direct  
sunlight.  
Firmly insert the power plug as far it can go  
into the power outlet.  
Do not install the scanner under direct  
sunlight or near heating apparatus. Doing  
so might cause excessive heat to build up  
inside the scanner, which can cause  
scanner trouble or even fire. Install the  
scanner in a well-ventilated location.  
vii  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Chapter 1  
Scanner Features  
1.2 Logging In  
The scanner functions available after login vary in the following ways for different types of user:  
For more details, refer to the "Operator's Guide".  
1.1 Scanner Features  
Administrator  
Use for scanned documents with ease  
This easy-to-operate network scanner may be used to scan documents for further use:  
1. Scanned document files can be sent as an e-mail attachment.  
2. Scanned document files can be sent by fax.  
Can setup and manage the scanner.  
Regular User  
Can scan documents and then send, print, or save the resulting data.  
1.3 From Arrival through Operation  
3. Scanned document files can be printed on a network printer.  
4. Scanned document files can be saved in a network folder.  
Refer to "1.4 Checking the Contents of the Scanner Package"  
(page 2).  
Check package  
Send e-mail  
1
SMTP Server  
Internet  
Send Fax  
2
3
Refer to "Chapter 2 Setting up the Scanner" (page 4).  
Setup scanner  
Original  
Document  
Fax Server  
Refer to "Chapter 3 Setting up for Network Use" (page 6).  
Refer to "Chapter 4 Installing the Admin Tool" (page 12).  
Setup network  
Scanned Data  
LDAP Server  
Scanner  
Print  
User  
Authentication  
Print Server  
Install the Admin Tool  
Download manual  
Perform scan test  
User function settings  
Operation  
FTP Server  
or  
4
Network  
Folder  
File Server  
Save  
Refer to "Chapter 5 Downloading the Manual" (page 14). This  
manual is the "Operator’s Guide".  
Configure and manage with ease  
Configuration and management of the scanner can be easily performed via the touch panel, or via the fi Network Scan-  
ner Admin Tool (hereinafter referred to as Admin Tool) or the iScanner Central Admin Console (hereinafter referred to  
as Central Admin Console), installed on a personal computer. For more details how to install, refer to the "Operator's  
Guide".  
Refer to "Chapter 6 Performing a Scan Test" (page 15).  
Refer to the "Operator's Guide".  
Personal computer  
Personal computer  
Central Admin Console  
Admin Tool  
Set multiple scanners  
at a time via the  
network interface  
Central Admin  
Set one scanner at  
a time via the  
network interface  
Server  
Refer to the "Operator's Guide".  
Touch Panel  
Directly set one  
scanner at a time  
Scanner  
Scanner  
Scanner  
Scanner  
1.4 Checking the Contents of the Scanner Package  
When you open the scanner package, please handle the main unit and its attachments carefully.  
Make sure the scanner package contains all the parts listed in "Checking the Package Contents" that is included in the  
package box.  
If any parts are missing or defective, contact your FUJITSU scanner dealer or an authorized FUJITSU scanner service  
provider.  
Advanced security measures  
The following security functions are provided for the scanner.  
Login authentication can restrict user access.  
Scans can be converted to password protected PDF files.  
Scanned data is always encrypted in the scanner and deleted after it is sent as an e-mail or by fax, printed, saved  
in a folder.  
1
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Chapter 2  
Setting up the Scanner  
Removable Parts  
1.5 Names and Functions of  
Parts  
Parts that can be removed from the scanner are dis-  
played below.  
2.1 Space Requirements  
This section describes the scanner parts and their func-  
tions.  
The following space is required to set up the scanner:  
Depth: 700mm (28in)  
Separate shaft  
and roller  
Front  
Width: 400mm (16in)  
Height: 500mm (20in)  
Pad assembly  
Startup button  
ADF paper chute  
2. Connect the AC adapter connector to the scan-  
ner's DC inlet.  
2.2 Installing the Scanner  
Pick roller  
Side guides  
Sheet guide  
Top cover  
When lifting the scanner, always  
hold it by the indentations on the  
bottom of each side to ensure a  
stable grip.  
[SCAN] button  
LCD touch panel  
Keyboard  
Holding the scanner in any other  
way may cause it to be dropped  
or damaged.  
ADF paper chute  
Output tray  
3. Connect the LAN cable to the LAN connector.  
Back cover  
Rear  
To remove the back cover of the  
scanner, press the tabs on the cover  
to unlock it, and pull out. Make sure  
to pull the cover out straight, to pre-  
vent the it from being damaged.  
ATTENTION  
ADF release button  
4. Attach the back cover.  
1. Place the scanner at its installation site.  
2. Attach the ADF paper chute.  
Attach the cover with the connected AC cable  
and LAN cable protruding out of the lower part  
of the cover.  
Press the tabs on the  
right and left of the cover  
and pull out.  
Hold the ADF paper chute and insert its tabs into  
the corresponding slots in the scanner as shown in  
the following figure.  
Back cover  
The side guides of the ADF paper chute should  
face up.  
Inside the back cover  
Tab  
To make sure the cover is properly attached,  
insert the right and left tabs at the same time.  
5. Connect the other end of the LAN cable to the  
network hub.  
Security cable slot  
LAN connector  
Tab  
AC adaptor connector  
6. Insert the AC cable into a power outlet.  
The power is connected but the scanner is not  
yet ready for operation.  
2.3 Connecting the Cables  
1. Connect the AC cable to the AC adapter.  
Use only the AC adapter provided by  
ATTENTION  
the manufacturer.  
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Chapter 3  
Setting up for Network Use  
2.4 Attaching the Keyboard  
Cover  
Top-left guide  
3.1 Logging in  
Top-center guide  
The layout of the keyboard may differ according to the  
language selected for the operating environment. The  
layout of each keyboard cover is prepared according to  
language requirements. Take the keyboard cover for the  
selected language out of its packaging, and attach it to  
the scanner. This scanner is set up for use with an  
English (US) keyboard. Therefore, if the scanner is to be  
used with an English (US) keyboard attaching a key-  
board cover is not required.  
Do not move or shake the  
Top-right guide  
scanner when it is turned on.  
This can damage the rotating  
hard disk drive and cause data to  
be lost.  
Top  
attachment  
area  
Ԙ
ԙ
Ԛ
To set up the network connection, you must login as the  
administrator. The user name and initial password for  
the administrator are as follows:  
Check that the power is turned off  
ATTENTION  
before attaching the keyboard cover.  
User Name: admin  
Password: password  
You can select whether or not to display  
this screen again at the next start up. To  
display the screen again, for "Show this  
message at next start up?", press the  
[Yes] button. To not display this screen at  
next start up, press the [No] button.  
To change the setting back to displaying  
this screen at the next start up, login as  
the administrator and for "Show the  
"Language/Keyboard Selection" screen  
at next start up?", press the [Yes] button  
on the "Language/Keyboard Selection"  
screen.  
HINT  
4. Flip up the keyboard cover and remove the  
paper backing from the bottom strip of double-  
sided tape.  
1. Press the startup button.  
1. Clean the surface of the keyboard.  
Pay particular attention  
to these areas  
Flip up the  
Paper  
Startup button  
keyboard cover  
backing tape  
After the system starts up, the "Language /  
Keyboard Selection" screen appears.  
3. Press the [OK] button.  
The "Login" screen appears.  
After turning the power off, wait for at  
ATTENTION  
2. Turn the keyboard cover over and remove the  
paper backing from the top strip of double-  
sided tape.  
least ten seconds before turning the  
power back on again.  
5. Gently stretch the keyboard cover forward and  
smooth the double-sided tape down.  
If the language is changed in Step 2,  
ATTENTION  
the following screen appears.  
The message is displayed in the  
selected language.  
Paper backing tape  
Bottom  
attachment area  
If touch panel responses seem out of  
alignment with the positions of  
objects on the LCD screen, calibrate  
the screen.  
Underside  
HINT  
For details, refer to "Appendix A Cali-  
brating the Touch Panel" (page 18).  
3. Align the top edge of the keyboard cover with  
the protruding guides, and firmly smooth the  
double-sided tape down.  
2. Select a language.  
Select the desired language for the operating envi-  
Align and attach the top-left corner first, then the  
center, and last the top-right corner.  
ronment. The default language is "English (US  
Keyboard)".  
Pressing the [OK] button restarts the  
scanner, and the "Login" screen.  
Continue setting up the network.  
4. Enter the user name.  
User name is case sensitive. Enter "admin" here.  
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
4. Press the [OK] button.  
3. Press the [List] button for the "Timezone" input  
field.  
4. Enter the "Current Password", "New Pass-  
word", and "Confirm New Password".  
The restart confirmation screen appears.  
5. Press the [Later] button.  
The default timezone is "(GMT+09:00) Osaka,  
Sapporo, Tokyo".  
Passwords must be between 7 and 127 characters  
long.  
Alphanumeric characters (case sensitive) and  
symbols may be entered.  
A list of timezones appears.  
4. Select a timezone.  
5. Press the [OK] button.  
The new admin password is set.  
3.3 Setting the Scanner Name  
A scanner name may be set to provide a network alias  
for the device.  
The current scanner name, or changed scanner  
5. Enter the password.  
Password is case sensitive.  
Enter "password" here.  
name after next restart, is displayed.  
Do not use a name that is already  
being used in the network.  
ATTENTION  
Name duplication will cause a net-  
work connection error.  
6. Press the [Login] button.  
5. Select whether "Daylight Savings Time" should  
be on or off.  
If the scanner name is the same as  
one already in use, network communi-  
If the administrator name and password are  
valid, the "System Settings" screen appears.  
HINT  
cation problems will occur. In this  
case, try the following steps:  
1. Disconnect the LAN cable, press  
the [Shutdown] button on the  
touch panel, and turn the scan-  
ner off.  
This option is not shown for timezones where  
daylight savings time is not used.  
1. Select the [System Settings] tab on the top  
menu.  
3.2 Changing the Administrator  
Password  
6. Press the [OK] button.  
2. Select the [Scanner Name] tab on the left side  
menu.  
The Region/Timezone is set.  
Continue with IP address/DHCP settings.  
If you change the password, save  
ATTENTION  
2. Reboot the scanner with the  
LAN cable disconnected, and  
the new password in a safe location.  
3.5 Setting the IP Address/DHCP  
An IP address must be set in order to connect the scan-  
ner to a network.  
If you lose the password, contact  
your FUJITSU scanner dealer or an  
authorized FUJITSU scanner service  
provider. This may incur a cost to  
reset the scanner.  
enter  
a
non-duplicate scanner  
name.  
3. Reboot the scanner again.  
4. Re-connect the LAN cable to the  
scanner.  
Do not use an IP address that  
ATTENTION  
already exists in the network.  
IP address duplication will cause  
an error during setup.  
The administrator password can be changed.  
Restart may be performed after all necessary settings  
have been completed.  
Continue with the Region/Timezone settings.  
1. Select the [System Settings] tab on the top  
menu.  
1. Select the [Network Settings] tab on the top  
menu.  
2. Press the [ ] button on the left side menu.  
3.4 Setting the Region/Timezone  
1. Select the [System Settings] tab on the top menu.  
Scroll the left side menu down until the  
[Admin Password] tab appears.  
2. Select the [IP Address] tab on the left side  
menu.  
The "Scanner Name" screen appears.  
2. Select the [Region/Timezone] tab on the left  
side menu.  
3. Enter a scanner name.  
3. Select the [Admin Password] tab on the left  
side menu.  
Scanner names may be up to 15 characters long.  
Use only alphanumeric characters (case sensitive)  
and hyphens.  
Scanner names cannot consist of numerical char-  
acters only.  
A hyphen cannot be used as the first character of a  
scanner name.  
The scanner can be setup to be a  
HINT  
workgroup or domain member.  
The IP address/DHCP screen appears.  
The "Region/Timezone" screen appears.  
The "Admin Password" screen appears.  
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
4. Select whether or not to enable SSL.  
3. Enter the following numerical addresses:  
3. Set the scanner's IP address. This may be  
done automatically, by pressing the DHCP [On]  
button.  
3.6 Setting the Admin Network  
Select the [On] button enables SSL. If SSL is  
enabled, press the [Regenerate] button to create  
another SSL Certificate. When a new SSL Certifi-  
cate is created, the contents of the certificate are  
changed. The contents of the SSL Certificate are  
as follows.  
Primary DNS  
Secondary DNS  
Set the network settings for connecting to a scanner  
from the Admin Tool or Central Admin Server.  
The IP address may also be set manually, by  
pressing the DHCP [Off] button and entering  
the following numerical addresses:  
If a DNS server setting is not required, enter  
"0.0.0.0".  
1. Select the [Network Settings] tab on the top  
menu.  
IP Address  
Subnet Mask  
Default Gateway  
2. Select the [Admin Network] tab on the left side  
menu.  
A Secondary DNS cannot be set  
without a Primary DNS.  
Issued by  
ATTENTION  
Displays the SSL Certificate issuer.  
Valid from  
Displays the SSL Certificate expiration date.  
The expiration date is five years from the  
date on which the certificate was created.  
This is shown in date form.  
DNS Dynamic Update and DNS Suf-  
fix can also be set.  
Selecting the [Off] button disables SSL.  
HINT  
The current FQDN is shown for the  
FQDN. However, if the scanner is not  
connected to the network, the FQDN  
may not be displayed correctly.  
5. Press the [OK] button.  
The communication settings are set.  
The following settings combinations  
ATTENTION  
are not possible.  
4. Press the [OK] button.  
Port Number "80" and SSL "On"  
Port Number "443" and SSL "Off"  
The "Admin Network" screen appears.  
The information entered is set.  
4. Press the [OK] button.  
3. Enter a port number from 1 to 65535, to be  
used by the scanner to communicate with the  
Admin Tool or Central Admin server.  
The information entered is set.  
Continue with the WINS settings.  
Continue with the DNS settings.  
3.8 Setting the WINS Server  
A primary WINS and secondary WINS can be set.  
If the IP address is the same as one  
HINT  
The default setting is 80.  
3.7 Setting the DNS Server  
A primary DNS and secondary DNS can be set.  
already in use, network communica-  
tion problems will occur. In this case,  
try the following steps:  
1. Select the [Network Settings] tab on the top  
menu.  
Port numbers 135, 139, 445, and  
numbers from 1025 to 1124, cannot  
be specified as they are already  
reserved in the scanner.  
1. Select the [Network Settings] tab on the top  
menu.  
ATTENTION  
1. Disconnect the LAN cable, press  
the [Shutdown] button on the  
touch panel, and turn the scan-  
ner off.  
2. Press the [ ] button on the left side menu.  
2. Select the [DNS Server] tab on the left side  
menu.  
Scroll the left side menu down until the  
[WINS Sever] tab appears.  
If port numbers other than  
2. Reboot the scanner with the  
LAN cable still disconnected,  
HTTP:80, HTTPS:443 are to be  
specified, it is recommended that  
numbers over 5000 are used. If a  
port number lower than 5000 is  
specified, verify the Admin Tool  
connectivity with the port number  
first.  
3. Select the [WINS Server] tab on the left side  
menu.  
and enter  
address.  
a
non-duplicate IP  
3. Re-connect the LAN cable to the  
scanner.  
When DHCP is set to "On", the follow-  
ing settings are assigned by the  
DHCP:  
IP Address  
Subnet Mask  
Default Gateway  
DNS Server  
WINS Server  
Domain Suffix  
The "DNS Server" screen appears.  
Even if DNS or WINS server is set, pri-  
ority is given to the scanner settings  
over the DHCP settings.  
The "WINS Server" screen appears.  
Continue with the connection settings.  
9
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Chapter 4  
Installing the Admin Tool  
4. Enter the following numerical addresses:  
5. Press the [Ping] button.  
Primary WINS  
Secondary WINS  
A ping test is performed and the results are  
displayed. If the result shows "Lost=0 (0%  
loss)", the network connection is functioning  
normally. For any other result, refer to  
"Checking Basic Network Operation with a  
Ping Test" (page 23).  
As well as operating via the touch panel, the administra-  
tor can configure scanner settings via the network inter-  
face. In order to do this, the Admin Tool, or Central  
Admin Console, must first be installed on a personal  
computer connected to the network.  
The Admin Tool can set one scanner at a time. The Cen-  
tral Admin Console can set multiple scanners at a time.  
For more details about the Central Admin Console, refer  
to the "Operator's Guide".  
SSL is [On], no port number change  
If a WINS server setting is not required, enter  
"0.0.0.0".  
SSL is [On], port number change  
For port_number, enter the changed port number  
For SSL, the "Security Alert" window is dis-  
A Secondary WINS cannot be set  
without a Primary WINS.  
ATTENTION  
played when connecting. Press the [Yes] button  
on the "Security Alert" window.  
The "Login" screen appears.  
2. Enter a "User Name" and "Password", and  
press the "Login" button.  
This chapter provides a description of the Admin Tool.  
The information and procedure for installing the Admin  
Tool are as follows.  
5. Press the [OK] button.  
The information entered is set.  
Software  
Operating system  
Next, check the network connection.  
3.9 Checking the Network  
Connection  
Windows® XP SP2 or later  
Windows Vista®  
Windows Server® 2003 SP2 or later  
Windows Server® 2008  
The network connection may be checked by performing  
a ping test.  
.NET Framework 2.0 SP1 or later, or  
.NET Framework 3.0 SP1 or later (*1)  
Microsoft® Internet Explorer 6 SP2 or  
later (*2)  
After performing all settings, restart the system.  
1. Select the [Network Settings] tab on the top  
menu.  
The "Download" screen appears.  
3. Press the [Next] button for the fi Network Scan-  
ner Admin Tool download.  
Hardware  
32 MB or more of free memory space  
64 MB or more of free disk space  
2. Press the [ ] button on the left side menu.  
Scroll the left side menu down until the [Ping]  
tab appears.  
3.10 Restarting the System  
Any personal computer which runs the  
supported software  
1. Press the [Logout] button.  
The restart confirmation screen appears.  
2. Press the [Restart] button.  
XGA monitor or better  
3. Select the [Ping] tab on the left side menu.  
LAN cable  
Pointing device (e.g. mouse)  
*1: When installing the Admin Tool, confirm that .NET  
Framework is installed. If not already installed, a message  
will appear telling you to install .NET Framework from  
the Microsoft Web site. When installing .NET Frame-  
work, at least 280MB of additional free disk space is  
required.  
*2: Confirm that the latest security patch has been applied. If  
the latest patch has not been applied, downloading opera-  
tions (such as manual download) may not be possible. For  
Windows® XP, "KB933566" must be applied to  
Microsoft® Internet Explorer.  
The fi Network Scanner Admin Tool down-  
load screen appears.  
4. Press the [Download] button.  
The scanner restarts, and the "Login" screen  
appears.  
1. Specify the scanner name as a URL in the web  
browser's location bar.  
The "Ping" screen appears.  
Next, install the Admin Tool.  
4. Enter the IP address, host name, or FQDN for  
the server to be used to check the network  
connection.  
According to the settings from "3.6 Setting the  
Admin Network" (page 9), the specified URL is  
as follows:  
SSL is [Off], no port number change  
SSL is [Off], port number change  
For port_number, number enter the changed port  
number  
For an IP address  
The following format should be used  
xxx.xxx.xxx.xxx (xxx is a value from 0 to 255).  
For a host name or FQDN  
Up to 255 characters may be used.  
11  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Chapter 5  
Downloading the Manual  
In addition to this "Getting Started" guide, a "Operator's  
Guide" is also available.  
The "Operator's Guide" contains information about  
scanner settings, scanner administration, and scanner  
operations.  
Consult this manual when using the scanner.  
The "Operator's Guide" is a PDF file, and can be viewed  
with Adobe® Reader® (*).  
* Adobe® Reader® can be downloaded from the fol-  
lowing site.  
3. Press the [Connect] button.  
Downloading is not possible while  
an administrator or user operation  
is being processed.  
Installation will fail if the length of  
any installation path (folder path plus  
installation file name) exceeds 259  
characters. Select an installation  
folder that respects this limit.  
ATTENTION  
ATTENTION  
The "Login" screen appears.  
4. Press the [Download Manual] button.  
Do not close the Web browser or  
logout until installation is complete.  
The "File Download - Security Warning"  
screen appears.  
5. Press the [Run] button.  
Login as the administrator via the network interface to  
download the "Operator's Guide".  
The download procedure is as follows:  
1. From the [Start] menu, point to [All Programs] -  
[fi-scanner V2.1], and then click [fi Network  
Scanner Admin Tool].  
The fi Network Scanner Admin Tool Setup  
Wizard appears.  
The "File Download" dialog box appears.  
8. Select the target user(s), and press the [Next]  
button.  
5. Press the [Save] button.  
The Admin Tool is started.  
2. Specify the "Connect to" (of the scanner).  
If .NET Framework is not installed,  
download and install ".NET Framework  
Redistributable Package" from the  
Microsoft Website. After installing the  
package, try again from Step 1.  
Enter the IP address, scanner name, or FQDN  
name for the scanner to be setup or managed.  
HINT  
The "Save As" dialog box appears.  
6. Press the [Next] button.  
When the [Download Manual] button  
ATTENTION  
is pressed, if Adobe® Reader® has  
not been installed, and the [Open]  
button on the "File Download" dialog  
box is pressed, a "Connection error"  
will occur.  
Follow the prompts of the install wizard  
windows until a "fi Network Scanner Admin  
Tool has been successfully installed" message  
indicates that the installation has completed.  
Press the [Close] button.  
6. Select a folder and enter a file name.  
When the installation is completed, logout of  
the scanner, and close the Web browser.  
The Admin Tool should now be usable.  
Click the [Start] button, select the  
If the port number was changed in  
"3.6 Setting the Admin Network"  
(page 9) enter the changed port  
number for "Port Number".  
When trying to connect with a port  
number other than the specified  
number, it will take up to 20 sec-  
onds before a connection error  
occurs.  
ATTENTION  
The "Select Installation Folder" window  
appears.  
[All Programs] - [fi-scanner V2.1] sub-menu,  
and then click on the [fi Network Scanner  
Admin Tool].  
7. Specify an installation folder for the Admin  
Tool.  
To select a different folder, press the [Browse]  
button.  
To check the free space available for the currently  
selected folder, press the [Disk Cost] button.  
For more details about configuring settings with, or  
uninstalling the Admin Tool, refer to the "Operator's  
Guide".  
To use SSL, select the [Use HTTPS]  
checkbox.  
If the Admin Tool is started while  
there is insufficient free memory, a  
script error may occur. Try again  
after ensuring that there is enough  
free memory.  
7. Press the [Save] button.  
The file is saved.  
Next, download the "Operator's Guide".  
Next, perform a scan test.  
13  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Chapter 6  
Performing a Scan Test  
7. Check the scanned data.  
If no document is loaded  
Message  
Document not found. Load a document into the  
ADF, making sure the side guides are adjusted  
correctly and try again.  
Perform a scan test to determine if the scanner is work-  
ing properly. Login as a regular user to perform the  
scan test.  
4. Select the [Maintenance] button on the "Main  
Menu" screen.  
Action  
1. Load the documents to be test scanned.  
Load a document, and try the scan test again.  
If a multifeed is detected  
Message  
Feed Error: Document(s) may not match the set  
paper size, ADF may have grabbed more than  
one sheet, or documents may not be suitable for  
scanning. Remove the documents from the ADF,  
check them and try again. If problem persists,  
consult the manual.  
8. Press the [OK] button.  
Action  
Remove the document for which multifeed was  
detected, and try the scan test again.  
If a paper jam occurs  
The "Maintenance" screen is shown again.  
The "Login" screen appears.  
However, if the scanner is setup for automatic  
login, the "Login" screen is not shown.  
Proceed to Step 4.  
The "Maintenance" screen appears.  
If Scanning Completes  
Message  
5. Press the [Scan Test] button.  
Successfully  
Paper jam has occurred. Remove the documents  
from the ADF and try again.  
Action  
If the "Scan Viewer" screen appears with par-  
tially scanned data, just click the [OK] button.  
Remove any unscanned documents from the  
ADF. Open the scanner's top cover, remove the  
jammed document from the scanner, and close  
the scanner's top cover. From the "Maintenance"  
screen, try the test scan again.  
Continue with the setting procedures described in Chap-  
ter 1 of the "Operator's Guide".  
2. On the "Login" screen, enter a "User Name"  
and "Password".  
To disable login with a guest  
Enter "guest" for the User Name and Password  
fields.  
ATTENTION  
account, select [Off] for "Guest  
Account" in the [System Settings]  
screen on the [Login Settings] tab.  
If a problem is detected with the scanner  
System settings or user data can be  
backed up from the [User Data Store]  
Message  
HINT  
Scanner initialization has failed. Try turning the  
power off and back on again. The administrator  
should contact the FUJITSU scanner dealer or  
an authorized FUJITSU scanner service provider  
for help.  
Action  
Try the following:  
or [System Settings File] screen on  
the [Maintenance] tab. This can only  
be performed via the network  
interface. Backup should be per-  
formed regularly. This can only be  
performed via the network interface  
using the Admin Tool or Central Admin  
Console.  
The scan settings information for the scan test  
is displayed.  
6. Press the [Scan] button.  
If the scanner does not restart automatically,  
press the [Shutdown] button on the "Login"  
screen to turn the power off, and turn the  
power back on again to restart the scanner.  
If the error status persists after the scanner is  
restarted, press the [Shutdown] button on the  
"Login" screen, disconnect the AC cable  
from the scanner to turn the power off, wait  
for at least ten seconds, then reconnect the  
AC cable and try turning the power back on  
again. If the error status persists, contact  
your FUJITSU scanner dealer or an  
3. Press the [Login] button.  
For more details, refer to the "Opera-  
tor's Guide".  
If the user name and password are valid, the  
"Main Menu" screen appears.  
If Scanning does not Complete  
Successfully  
If the top cover is open  
Message  
Top cover may be open. Close the top cover,  
reload the documents and try again.  
Action  
Scanning starts. When the scan has completed,  
the "Scan Viewer" opens.  
authorized FUJITSU scanner service  
provider.  
Close the top cover, and try the scan test again.  
15  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Appendix A Calibrating the Touch Panel  
If some other error occurs  
Message  
An error has occurred. Try turning the power off  
and back on again. The administrator should  
contact the FUJITSU scanner dealer or an autho-  
rized FUJITSU scanner service provider for  
help. [alphanumeric eight digits]  
Action  
This should be done if and when the touch panel  
responses seem out of alignment with the positions of  
objects on the LCD screen.  
The keyboard may also be used on the  
calibration screen:  
HINT  
Press the [Home] key to jump straight to  
the post-calibration test screen.  
1. Login as the administrator.  
Use the arrow keys to move the "+"  
to a different calibration point. This  
allows a bad touch to be redone.  
Press the [Esc] key to stop the cali-  
bration process and return to the  
"Screen Calibration" screen.  
For details, refer to "3.1 Logging in" (page 6).  
The "System Settings" screen appears.  
Try the following:  
If the scanner does not restart automatically,  
press the [Shutdown] button on the "Login"  
screen to turn the power off, and turn the  
power back on again to restart the scanner.  
If the error status persists after the scanner is  
restarted, press the [Shutdown] button on the  
"Login" screen, disconnect the AC cable  
from the scanner to turn the power off, wait  
for at least ten seconds, then reconnect the  
AC cable and try turning the power back on  
again. If the error status persists, contact  
your FUJITSU scanner dealer or an  
2. Select the [System Settings] tab on the top  
menu.  
Press the [Enter] key to close the  
error dialog. (Not normally needed.)  
3. Select the [Screen Calibration] tab on the left  
side menu.  
The "Calibration Screen" appears.  
Repeat until the test screen appears, with the fol-  
lowing "Calibration" dialog box:  
4. Press the [Calibrate Screen] button.  
authorized FUJITSU scanner service  
provider.  
6. Trace a line on the screen with your fingertip.  
A corresponding line will appear on-screen.  
If the line does not appear correctly, press the  
[Calib screen] button to return to Step 5.  
If the screen becomes cluttered, press the  
[CLR screen] button to remove all the lines.  
The [Cursor on/off] button cannot be used.  
7. When you are satisfied with the touch screen  
response, press the [Update] button.  
This saves the current calibration data, com-  
pleting the calibration process, and returns you  
to the "Screen Calibration" screen.  
A blank calibration screen appears, with a red  
"+" (adjustment mark) in the top-left corner.  
5. Touch the "+" with your fingertip.  
After being touched, the "+" will move to  
the next calibration position. Each time  
it stops, touch it again.  
If the calibration is not performed  
carefully, or the [Enter] key is pressed  
before all the calibration points have  
been touched, the following error  
message may appear:  
ATTENTION  
Parameter Error. Please input, again  
Press the [Enter] key to dismiss the  
error dialog, and perform the calibra-  
tion again, being careful to touch each  
calibration point accurately.  
17  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Appendix B Scanner Care  
Cleaning the Keyboard/Keyboard  
Cover  
Which Parts and When  
To prevent the keyboard (and / or keyboard cover) from  
becoming dirty, it should also be regularly cleaned with  
a soft, dry cloth.  
The glass scanner windows  
inside the ADF can become hot  
when the scanner is used.  
Before cleaning inside the  
scanner or replacing any parts,  
turn off the power, unplug the AC  
adapter from the outlet, and wait  
for at least 15 minutes.  
Clean all parts after every 1,000 sheets scanned.  
Pad assembly  
Feed rollers  
Pick roller  
Idler rollers  
Glass scanner windows  
Ultrasonic sensor  
Always use a dry (not damp) cloth to  
ATTENTION  
clean the keyboard (with or without  
The power does not need to be  
turned off when cleaning the  
feed rollers.  
cover). Do not apply Cleaner F1.  
Replace the keyboard cover if stains  
cannot be removed by cleaning.  
For more details, refer to the  
"Operator's Guide".  
The scanner must be cleaned more  
ATTENTION  
frequently when the following types  
of documents are used:  
Do not use any aerosol sprays  
or alcohol based sprays to clean  
the scanner.  
Dust blown up by strong air from  
the spray may enter the inside of  
the scanner. This may cause the  
scanner to fail or malfunction.  
Sparks, caused by static  
electricity, generated when  
blowing off dust and dirt from the  
outside of the scanner may  
cause a fire.  
Coated paper  
Documents with large areas of  
printing  
To obtain a keyboard cover, contact your FUJITSU dealer  
or an authorized FUJITSU scanner service provider.  
Chemically treated paper such as  
carbonless paper  
Part Name  
Part No.  
Remarks  
Paper containing large amounts of  
calcium carbonate filler  
Documents written in pencil  
Documents with insufficiently fused  
toner  
Keyboard cover PA03544- 1 cover  
K608  
GBR: English (UK)  
Cleaning the Carrier Sheet  
Cleaning Materials  
If the surface or interior of the carrier sheet becomes  
dirty or dusty, use a soft dry cloth slightly moistened  
with Cleaner F1 (sold separately) or a mild detergent, to  
lightly wipe off the dirt and dust.  
Cleaning  
Materials  
For more details, refer to the "Operator's Guide".  
Part No.  
Remarks  
Cleaner F1  
PA03950- 1 bottle  
0352 Used to moisten the  
Cleaning the ADF  
Clean the ADF with a soft cloth moistened with Cleaner  
F1. For details, refer to the "Operator's Guide".  
cloths before wiping  
parts clean.  
Never use paint thinner or other  
organic solvents.  
ATTENTION  
Cleaning Paper CA99501- 1 pack (10 sheets)  
Do not rub too hard, as the carrier  
sheet may become scratched or  
deformed.  
Cleaning the LCD Touch Panel  
0012  
For use with Cleaner  
F1.  
To prevent the touch panel screen from becoming dirty,  
it should be regularly cleaned with a soft, dry cloth.  
Take care when cleaning the touch panel. It can be eas-  
ily damaged, and should never be scratched or banged  
with hard objects.  
After cleaning the interior of the  
carrier sheet, wait until it has com-  
pletely dried before closing it.  
As a guideline, it is recommended  
to replace the carrier sheet every  
500 scans.  
Cleaning Wipe PA03950- 1 pack (24 sheets)  
0419  
Pre-moistened with  
Cleaner F1, Cleaning  
Wipes are used instead  
of moistened cloths.  
Soft, dry cloth Any commercially available lint-  
free product  
Always use a dry (not damp) cloth to  
ATTENTION  
clean the screen. Do not apply  
Cleaner F1.  
Contact your FUJITSU scanner dealer or an authorized  
FUJITSU scanner service provider to obtain these products.  
If dust is allowed to collect and  
harden around the frame of the  
screen, it can cause the touch panel  
to malfunction.  
19  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Appendix C Replacing Parts  
Part No. and Replacement Cycle  
for Carrier Sheet  
The glass scanner windows  
inside the ADF can become hot  
when the scanner is used.  
One "Carrier Sheet" is provided with the scanner. If the  
"Carrier Sheet" provided with the scanner can no longer  
be used for scanning due to damage or wear-and-tear,  
you can purchase a new Carrier Sheet separately.  
The following table specifies the replacement number  
and the standard replacement cycle for carrier sheets.  
Use only the PFU LIMITED parts  
specified. Do not use consumable  
parts made by other manufacturers.  
ATTENTION  
Before cleaning inside the  
scanner or replacing any parts,  
turn off the power, unplug the AC  
adapter from the outlet, and wait  
for at least 15 minutes.  
The following diagram shows the locations of the con-  
sumable parts in the scanner. For more details, refer to  
the "Operator's Guide".  
No. of  
Part Name  
Replacement Cycle  
items  
Carrier Sheet  
5
After used for 500  
scans  
Pad Assembly (PAD ASSY)  
(PA03360-0013)  
Part No. and Replacement Cycle  
Contact your FUJITSU scanner dealer or an authorized  
FUJITSU scanner service provider to obtain these prod-  
ucts.  
This replacement cycle is a rough guideline. This may  
vary according to the type of documents scanned, scan-  
ner usage, and cleaning frequency. If parts become  
noticeably dirty, replace them accordingly.  
for Consumable Parts  
The usage count of consumable parts can be checked in  
the "Usage Status" screen on the [Device Status] tab.  
Use only the PFU LIMITED parts  
ATTENTION  
specified. Do not use parts made by  
other manufacturers.  
Pick Roller  
Pick roller  
The following diagram shows the Carrier Sheet.  
For more details, refer to the "Operator's Guide".  
Carrier Sheet  
When parts need to be replaced soon, the "Status" infor-  
mation field becomes orange. When parts need to be  
replaced immediately, the "Status" information field  
becomes red.  
The following table specifies the replacement part num-  
bers and the standard replacement cycles.  
Part Name  
Replacement Cycle  
Pad assembly  
(Pad ASSY)  
After every 50,000 sheets  
scanned or once a year  
(PA03289-0111)  
Pick roller  
After every 100,000 sheets  
scanned or once a year  
(PA03289-0001)  
Pick roller's shaft  
To obtain these parts, contact your FUJITSU dealer or  
an authorized FUJITSU scanner service provider.  
These replacement cycles are rough guidelines when  
using 64 g/m2 (17 lb) A4/Letter woodfree or wood con-  
taining paper. They may vary according to the type of  
documents scanned, scanner usage, and cleaning fre-  
quency.  
21  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Appendix D Network Connection Troubleshooting  
Failure to Connect to a Server using its IP Address  
If a server cannot be connected to by using its IP address, and does not respond to a ping test, try the following steps:  
Checking Basic Network Operation with a Ping Test  
If a network connection is not possible, refer to "3.9 Checking the Network Connection" (page 11) for ping results and  
how to deal with them.  
No.  
Problem  
Action  
1
Connection error between a server and the Check that the LAN cable has been attached to both the scanner  
scanner, or problem with the LAN cable.  
and server correctly.  
Connection Server name  
Result  
Action  
If the server is connected using a LAN cable (straight type), in  
case auto-mdi (automatic selection) is not supported, a LAN  
cable (crossover type), switch, or router is required between the  
scanner and server.  
status  
setting  
"Ping statistics" shows OK  
"Lost=0 (0% loss)"  
IP address / host None  
name / FQDN  
If this is not the case, the LAN cable may be faulty. Find a  
LAN cable that functions normally and try again.  
"Ping statistics" shows NG  
"Lost=4 (100% loss)"  
IP address / host Check that the ping target IP address, host name, or  
name / FQDN  
FQDN is correct.  
2
3
IP address or subnet mask is invalid.  
On the "IP Address" screen, check that the IP address or subnet  
mask settings are correct.  
IP Address  
If the ping target IP address is correct, refer to "Fail-  
ure to Connect to a Server using its IP Address" (page  
24) for further solutions.  
For more details about the "IP Address" screen, refer to "3.5  
Setting the IP Address/DHCP" (page 8).  
Host name /  
FQDN  
On the "Network Status" screen, change [Link speed /  
Duplex mode] from "Auto-Negotiation" to a fixed mode.  
This can be changed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [ ] button on the left side menu.  
3. Select the [Network Status] tab on the left side menu.  
4. On the "Network Status" screen, select [Link Speed/  
Duplex Mode].  
When using DHCP, the DHCP server does Check the DHCP server connection status and the details of the  
server settings.  
not operate normally, or there is a problem  
with the DHCP server settings.  
If using DHCP, on the "Network Status" screen, check that IP  
address, subnet mask, and default gateway settings are all cor-  
rect.  
If these settings are not correct, the DHCP server may not oper-  
ate normally, or the DHCP server may not assign valid IP  
addresses because of restricted number of leases or MAC  
address validation.  
5. Press the [OK] button.  
"Ping statistics" shows NG  
"Lost=N (1 to 99%  
loss)"  
IP address / host There may be a problem with the quality of the LAN  
name / FQDN cable. Replace the LAN cable and try again.  
If the DHCP server operating environment is changed, restart  
the scanner.  
The "Network Status" screen can be displayed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [ ] button on the left side menu.  
3. Select the [Network Status] tab on the left side menu.  
IP address / host On the "Network Status" screen, change [Link speed /  
name / FQDN  
Duplex mode] from "Auto-Negotiation" to a fixed mode.  
This can be changed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [ ] button on the left side menu.  
3. Select the [Network Status] tab on the left side menu.  
4. On the "Network Status" screen, select [Link Speed/  
Duplex Mode].  
4
Another host or communication device is  
connected using the same IP address as  
the scanner.  
If the same IP address has already been used by another host or  
communication device, then even if the other device has been  
given a different IP address the server may not recognize the  
scanner’s "duplicate" IP address until it is rebooted. Restart the  
server.  
5. Press the [OK] button.  
"Hardware error"  
NG  
NG  
IP address / host The LAN cable may have become disconnected dur-  
If a duplicate IP address connection from another host or com-  
munication device exists on a LAN, both it will be unusable.  
If a duplicate IP address connection from another host or com-  
munication device exists, pull out its LAN cable and restart the  
server.  
name / FQDN  
ing the Ping test. Check the status of the LAN cable  
and try again.  
"Ping request could  
not find host  
Host name /  
FQDN  
Check that the ping target host name or FQDN is cor-  
rect.  
xxxxxxxxx. Please  
check the name and  
try again."  
Check that the DNS server or WINS server settings  
are correct.  
5
Access is denied due to the establishment If a firewall has been established between the server and the  
of a firewall between the server and the  
scanner.  
scanner, check that it has not been set to deny access to the net-  
work.  
If the ping target host name or FQDN is correct, refer  
to "Failure to Connect to a Server using its Host  
Name or FQDN" (page 25) for further solutions.  
OK: Connection is operating normally. NG: Connection is faulty.  
23  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
No.  
Problem  
Action  
No.  
Problem  
Action  
3
A misconfigured firewall between the  
Admin Tool or Web browser and the scan-  
ner, is denying access with HTTP/HTTPS  
protocol.  
If there is a firewall between the computer running the  
Admin Tool or Web browser and the scanner, check that it  
settings are not preventing access.  
6
The network link speed/duplex mode for  
the scanner and server are invalid, or  
Auto-Negotiation is not supported by the  
server.  
For this scanner, the default [Link Speed/Duplex Mode] setting  
is "Auto-Negotiation".  
On the "Network Status" screen, match the scanner and server's  
network link speed/duplex mode settings.  
If the problem persists in spite of having set both the scanner  
and server's network link speed/duplex settings to "Auto-Nego-  
tiation", change "Auto-Negotiation" to a fixed mode and check  
again.  
4
5
The URL of the target scanner is not regis-  
tered as a trusted site.  
Set the scanner URL as a trusted site for Internet Explorer. In  
Microsoft® Internet Explorer, set the following settings in the  
"Tools" menu, "Internet Options". In the [Security] tab, select  
[Trusted sites]. Press the [Sites] button, enter the URL of the  
scanner in the "Add this website to the zone" field, and press  
the [Add] button.  
On the "Network Status" screen, change [Link speed / Duplex  
mode] from "Auto-Negotiation" to a fixed mode.  
This can be changed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [ ] button on the left side menu.  
3. Select the [Network Status] tab on the left side menu.  
4. On the "Network Status" screen, select [Link Speed/Duplex  
Mode].  
In Microsoft® Internet Explorer, in the  
When connecting using the scanner name, the connection  
"Tools" menu, "Internet Options", [Security] will be an intranet connection. When connecting using an IP  
tab, the security level for the corresponding  
zone is set as "High", or in [Custom level],  
"Scripting", "Active scripting" is set to  
"Prompt" or "Disable".  
address, it will be an internet connection.  
In Microsoft® Internet Explorer, in the "Tools" menu,  
"Internet Options", try the following settings for the corre-  
sponding zone.  
5. Press the [OK] button.  
Failure to Connect to a Server using its Host Name or FQDN  
To enable "Active scripting", set in one of the following  
ways:  
If a server cannot be connected to by using its host name or FQDN, and does not respond to a ping test, try the following  
steps:  
In the [Security] tab, set the required "Security level  
for this zone" to "Medium".  
In the [Security] tab, click the [Custom level] button.  
Then, set the "Scripting", "Active scripting" to  
"Enable".  
No.  
Problem  
Action  
1
Same as in "Failure to Connect to a Server Check if a network connection is possible by trying the same  
using its IP Address" (page 24).  
solution for "Failure to Connect to a Server using its IP  
Address" (page 24).  
If connecting via the Internet zone, on the [Privacy] tab,  
set the level to below "Medium High".  
After the above settings have been performed, in "Tempo-  
rary Internet Files" or "Browsing history", press the [Delete  
cookies] button to delete all temporary internet files.  
2
3
The scanner's DNS server or WINS server Check that the DNS and WINS server settings are correct.  
settings are invalid.  
The DNS server or WINS server is not  
functioning normally, or there is an error  
with the DNS or WINS server network  
connection.  
Ping the DNS and WINS servers to check they are functioning  
normally.  
6
7
The scanner is in standby mode.  
A proxy server is being used.  
Press the startup button to start the scanner.  
If the DNS or WINS server is not functioning, request the net-  
work administrator to check its status.  
Set the proxy server to not be used.  
Open the "Internet Options" in the "Tools" menu of  
Microsoft® Internet Explorer, then press the [LAN settings]  
button in the [Connections] tab and remove the check from  
the "Use a proxy server for your LAN (These settings will  
not apply to dial-up or VPN connections)" option.  
Failure to Access the Scanner using a Web Browser, Admin Tool, or Central  
Admin Server  
If access is not possible when attempting to connect to the scanner using a Web browser or the Admin Tool, or when  
attempting to connect to the Central Admin Server from the Central Admin Console, try the following steps:  
8
There is an error with the connection proto-  
col setting.  
Check if SSL is enabled on the "Admin Network" screen.  
For more details, refer to "3.6 Setting the Admin Network"  
(page 9).  
No.  
Problem  
Action  
1
Same as in "Failure to Connect to a Server  
using its IP Address" (page 24).  
Check if a network connection is possible by trying the same  
solution for "Failure to Connect to a Server using its IP  
Address" (page 24).  
9
There is an error with the port number set-  
ting.  
Check the specified port number on the "Admin Network"  
screen. For more details, refer to "3.6 Setting the Admin  
Network" (page 9).  
2
The DNS server or WINS server is not func- Check the connectivity of the specified IP address.  
10  
In the Microsoft® Internet Explorer, "Tools" Open the "Internet Options" in the "Tools" menu of  
menu - "Internet Options" - [Advanced] tab, Microsoft® Internet Explorer, then press the [Advanced]  
tioning normally, or the scanner name has  
not been registered in the DHCP or WINS  
server.  
If it is possible to connect the scanner using the Admin Tool  
with a specified IP address, specify the scanner's IP address  
in the DNS or WINS server. Also, check the DNS or WINS  
server settings on the Admin Tool or Web browser.  
the [Use SSL 3.0] checkbox under "Set-  
tings" - "Security" section is not selected.  
tab, "Settings" - "Security" section, select the "Use SSL 3.0"  
checkbox.  
25  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Appendix E Troubleshooting  
Problem  
Check Item  
Suggestion  
Scanned data  
appears skewed or  
distorted.  
Has the document been loaded  
correctly?  
Load the document correctly.  
Problem  
Check Item  
Suggestion  
Scanner cannot be  
turned on.  
Has the Startup button been pressed? Press the Startup button.  
Quality of scanned  
data is poor.  
Are the glass scanner windows dirty? Clean the glass scanner windows.  
Are the AC cable and AC adapter  
properly connected to the scanner?  
Connect the AC cable and the AC adapter.  
Disconnect the AC cable from the scanner, wait at  
least ten seconds, then reattach the cable and turn  
the power back on again. If the problem persists,  
contact your FUJITSU scanner dealer or an  
authorized FUJITSU scanner service provider.  
Cannot login with  
administrator  
password.  
Was the Caps Lock on when the  
password was entered?  
Turn off the Caps Lock and try logging in again.  
If the password has been lost or forgotten, contact  
your FUJITSU scanner dealer or an authorized  
FUJITSU scanner service provider.  
The "Keyboard  
error or not  
After turning the scanner off, was the Disconnect the AC cable from the scanner, wait at  
Scanning does not  
start.  
Has the document been loaded  
Reload the documents into the ADF paper chute.  
power turned back on again  
immediately?  
least ten seconds, then reattach the cable and turn  
the power back on again. If the problem persists,  
contact your FUJITSU scanner dealer or an  
authorized FUJITSU scanner service provider.  
correctly into the ADF paper chute?  
keyboard present"  
message is shown  
on the screen, the  
scanner does not  
startup.  
Is the ADF completely closed?  
Close the top cover completely.  
Does the same problem occur after  
turning the scanner power off and  
back on again, and re-logging in?  
Disconnect the AC cable from the scanner, wait at  
least ten seconds, then reattach the cable and turn  
the power back on again. If the problem persists,  
contact your FUJITSU scanner dealer or an autho-  
rized FUJITSU scanner service provider.  
Input field entry  
entered via the key-  
board does not  
appear on the  
screen.  
Has the input field been selected?  
Select the input field and try again.  
Press the [Cancel] button and try again.  
Even after pressing  
the top cover  
[SCAN] button,  
scanning does not  
start.  
The top cover [SCAN] button can only be used on  
the following screens.  
To use the touch panel, touch the input field directly  
and try again  
"Send e-Mail" screen  
"Send Fax" screen  
"Print" screen  
Is the  
the touch panel?  
button displayed on  
Saving is not  
possible after  
pressing [Save] on  
the "File  
Download" dialog  
box.  
Does the length of the "Save As"  
folder path (folder path plus file  
name) exceed 259 characters?  
Select a "Save As" folder that respects the limit.  
"Save" screen  
"Scan Viewer" screen  
"Scan Test" screen  
"Message Screen"  
Status screen stops  
at "Printing scan  
data to...".  
Is there enough free space in the  
drive on which the spool folder for  
the print server exists.  
Make sure that there is enough space in the drive.  
Try pressing a different tab or button on the screen.  
Multifeed errors  
occur frequently.  
Do the documents satisfy the  
required quality conditions?  
Use documents which satisfy the quality conditions.  
For more details, refer to the "Operator's Guide".  
Has the document been loaded  
correctly into the ADF paper chute?  
Riffle and realign the document stack, then load it  
back into the ADF paper chute.  
No response from  
pressing tab or  
Has the [Download], [Get CSV] or  
[Backup] button been selected?  
Is the document stack more than 5  
mm thick?  
Remove sheets from the stack to reduce it to a  
thickness of 5mm or less.  
enter key after a file  
download operation  
has been selected  
via the network  
interface or the  
Is the pad assembly dirty?  
Clean the pad assembly.  
For more details, refer to the "Operator's Guide".  
Is the pad assembly worn out?  
Replace the pad assembly.  
For more details, refer to the "Operator's Guide".  
download process  
does not start.  
Paper is not fed into Do the documents satisfy the  
the scanner.  
(Pick errors are  
frequent or  
document feed  
stops midway)  
Use documents which satisfy the quality conditions.  
For more details, refer to the "Operator's Guide".  
required quality conditions?  
An error occurs  
when installing an  
Admin Tool.  
Is an Admin Tool of another lan-  
guage already installed?  
Uninstall the existing Admin Tool, and try again.  
Is the pick roller dirty?  
Clean the pick roller.  
For more details, refer to the "Operator's Guide".  
The login screen is  
not displayed when  
connecting via the  
network.  
Are the SSL settings correct?  
Close the screen, correct the settings, and try con-  
necting again.  
Is the pick roller worn out?  
Replace the pick roller.  
For more details, refer to the "Operator's Guide".  
Was the [Yes] button selected on the Close the screen and try connecting again. Select  
"Security Warning" dialog box when the [Yes] button on the "Security Warning" dialog  
Is there any foreign matter in the  
document feed path?  
Clean the document feed path.  
connecting with HTTPS?  
box when connecting.  
Scanned data is  
elongated.  
Are the feed rollers dirty?  
Clean the feed rollers.  
For more details, refer to the "Operator's Guide".  
Shadow on the  
leading edge of the  
scanned data.  
Are the feed rollers dirty?  
Clean the feed rollers.  
For more details, refer to the "Operator's Guide".  
Vertical line on the Are the glass scanner windows dirty? Clean the glass scanner windows.  
scanned data. For more details, refer to the "Operator's Guide".  
27  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-6010N Network Scanner Getting Started  
Copyright  
Portions Copyright © 1993 by Digital Equipment Corporation.  
2. Redistributions in binary form must reproduce the above  
copyright notice, this list of conditions and the following  
disclaimer in the documentation and/or other materials provided  
with the distribution.  
Permission to use, copy, modify, and distribute this software for any  
purpose with or without fee is hereby granted, provided that the  
above copyright notice and this permission notice appear in all  
copies, and that the name of Digital Equipment Corporation not be  
used in advertising or publicity pertaining to distribution of the  
document or software without specific, written prior permission.  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that the following conditions  
NetAdvantage 2007  
3. All advertising materials mentioning features or use of this  
software must display the following acknowledgement: "This  
product includes software developed by the Kungliga Tekniska  
Hogskolan and its contributors."  
are met:  
Copyright 2000-2007 Infragistics, Inc.  
1. Redistributions of source code must retain the above copyright  
notice, this list of conditions and the following disclaimer.  
LEADTOOLS for .NET  
2. Redistributions in binary form must reproduce the above  
copyright notice, this list of conditions and the following  
disclaimer in the documentation and/or other materials provided  
with the distribution.  
4. Neither the name of the University nor the names of its  
contributors may be used to endorse or promote products derived  
from this software without specific prior written permission.  
THE SOFTWARE IS PROVIDED "AS IS" AND DIGITAL  
EQUIPMENT CORP. DISCLAIMS ALL WARRANTIES WITH  
REGARD TO THIS SOFTWARE, INCLUDING ALL IMPLIED  
WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO  
EVENT SHALL DIGITAL EQUIPMENT CORPORATION BE  
LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR  
CONSEQUENTIAL DAMAGES OR ANY DAMAGES  
WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR  
PROFITS, WHETHER IN AN ACTION OF CONTRACT,  
NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT  
OF OR IN CONNECTION WITH THE USE OR PERFORMANCE  
OF THIS SOFTWARE.  
Copyright© 2005 LEAD Technologies, Inc.  
3. All advertising materials mentioning features or use of this  
software must display the following acknowledgement: "This  
product includes software developed by the University of  
California, Berkeley and its contributors."  
THIS SOFTWARE IS PROVIDED BY THE INSTITUTE AND  
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE  
IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.  
IN NO EVENT SHALL THE INSTITUTE OR CONTRIBUTORS  
BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES  
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,  
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER  
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING  
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE  
POSSIBILITY OF SUCH DAMAGE.  
WinPcap3.1  
Copyright © 1999 - 2005 NetGroup, Politecnico di Torino (Italy).  
Copyright © 2005 - 2006 CACE Technologies, Davis (California).  
All rights reserved.  
4. Neither the name of the University nor the names of its  
contributors may be used to endorse or promote products derived  
from this software without specific prior written permission.  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that the following conditions  
are met:  
THIS SOFTWARE IS PROVIDED BY THE INSTITUTE AND  
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE  
IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.  
IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE  
LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES  
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,  
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER  
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING  
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE  
POSSIBILITY OF SUCH DAMAGE.  
Portions Copyright © 1995, 1996, 1997, 1998, and 1999 WIDE  
Project.  
All rights reserved.  
1. Redistributions of source code must retain the above copyright  
notice, this list of conditions and the following disclaimer.  
2. Redistributions in binary form must reproduce the above  
copyright notice, this list of conditions and the following  
disclaimer in the documentation and/or other materials provided  
with the distribution.  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that the following conditions  
are met:  
3. Neither the name of the Politecnico di Torino, CACE  
Technologies nor the names of its contributors may be used to  
endorse or promote products derived from this software without  
specific prior written permission.  
1. Redistributions of source code must retain the above copyright  
notice, this list of conditions and the following disclaimer.  
Portions Copyright © 1997 Yen Yen Lim and North Dakota State  
University. All rights reserved.  
2. Redistributions in binary form must reproduce the above  
copyright notice, this list of conditions and the following  
disclaimer in the documentation and/or other materials provided  
with the distribution.  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that the following conditions  
are met:  
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT  
HOLDERS AND CONTRIBUTORS "AS IS" AND ANY  
EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT  
LIMITED TO, THE IMPLIED WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR  
PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE  
COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR  
ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,  
3. Neither the name of the project nor the names of its contributors  
may be used to endorse or promote products derived from this  
software without specific prior written permission.  
1. Redistributions of source code must retain the above copyright  
notice, this list of conditions and the following disclaimer.  
Portions Copyright © 1983 Regents of the University of California.  
All rights reserved.  
2. Redistributions in binary form must reproduce the above  
copyright notice, this list of conditions and the following  
disclaimer in the documentation and/or other materials provided  
with the distribution.  
THIS SOFTWARE IS PROVIDED BY THE PROJECT AND  
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE  
IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.  
IN NO EVENT SHALL THE PROJECT OR CONTRIBUTORS BE  
LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES  
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,  
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER  
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING  
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE  
POSSIBILITY OF SUCH DAMAGE.  
Redistribution and use in source and binary forms are permitted  
provided that the above copyright notice and this paragraph are  
duplicated in all such forms and that any documentation, advertising  
materials, and other materials related to such distribution and use  
acknowledge that the software was developed by the University of  
California, Berkeley. The name of the University may not be used to  
endorse or promote products derived from this software without  
specific prior  
EXEMPLARY, OR CONSEQUENTIAL DAMAGES  
3. All advertising materials mentioning features or use of this  
software must display the following acknowledgement: "This  
product includes software developed by Yen Yen Lim and North  
Dakota State University"  
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,  
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER  
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING  
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE  
POSSIBILITY OF SUCH DAMAGE.  
4. The name of the author may not be used to endorse or promote  
products derived from this software without specific prior written  
permission.  
written permission.  
THIS SOFTWARE IS PROVIDED BY THE AUTHOR "AS IS"  
AND ANY EXPRESS OR IMPLIED WARRANTIES,  
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED  
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT  
SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT,  
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR  
CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT  
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR  
SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND ON ANY  
THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT  
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF  
THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY  
OF SUCH DAMAGE.  
THIS SOFTWARE IS PROVIDED "AS IS" AND WITHOUT ANY  
EXPRESS OR IMPLIED WARRANTIES, INCLUDING,  
WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF  
MERCHANTIBILITY AND FITNESS FOR A PARTICULAR  
PURPOSE.  
This product includes software developed by the University of  
California, Lawrence Berkeley Laboratory and its contributors.  
This product includes software developed by the Kungliga Tekniska  
Hogskolan and its contributors.  
This product includes software developed by Yen Yen Lim and North  
Dakota State University.  
Portions Copyright © 1995, 1996, 1997 Kungliga Tekniska  
Hogskolan (Royal Institute of Technology, Stockholm, Sweden). All  
rights reserved.  
Portions Copyright © 1996 Juniper Networks, Inc. All rights  
reserved.  
Portions Copyright © 1990, 1991, 1992, 1993, 1994, 1995, 1996,  
1997 The Regents of the University of California.  
All rights reserved.  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that: (1) source code  
distributions retain the above copyright notice and this paragraph in  
its entirety, (2) distributions including binary code include the above  
copyright notice and this paragraph in its entirety in the  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that the following conditions  
are met:  
1. Redistributions of source code must retain the above copyright  
notice, this list of conditions and the following disclaimer.  
documentation or other materials provided with the distribution.  
29  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The name of Juniper Networks may not be used to endorse or  
promote products derived from this software without specific prior  
written permission.  
2. Redistributions in binary form must reproduce the above  
copyright notice, this list of conditions and the following  
disclaimer in the documentation and/or other materials provided  
with the distribution.  
THIS SOFTWARE IS PROVIDED "AS IS" AND WITHOUT ANY  
EXPRESS OR IMPLIED WARRANTIES, INCLUDING,  
WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR  
PURPOSE.  
3. Neither the name of the Politecnico di Torino, CACE  
Technologies nor the names of its contributors may be used to  
endorse or promote products derived from this software without  
specific prior written permission.  
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT  
HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS  
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED  
TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE ARE  
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT  
OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT,  
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR  
CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT  
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR  
SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND ON ANY  
THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT  
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF  
THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY  
OF SUCH DAMAGE.  
Portions Copyright © 2001 Daniel Hartmeier All rights reserved.  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that the following conditions  
are met:  
Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
Redistributions in binary form must reproduce  
the above copyright notice, this list of conditions  
and the following disclaimer in the  
documentation and/or other materials provided  
with the distribution.  
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT  
HOLDERS AND CONTRIBUTOR "AS IS" AND ANY EXPRESS  
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED  
TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE ARE  
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT  
HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY  
DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY,  
OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT  
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR  
SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND ON ANY  
THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT  
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF  
THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY  
OF SUCH DAMAGE.  
This product includes software developed by the University of  
California, Lawrence Berkeley Laboratory and its contributors.  
Secure iNetSuite 2.0J  
Copyright© 2007 Dart Communications  
fi-6010N Network Scanner  
Getting Started  
Portions Copyright 1989 by Carnegie Mellon.  
P3PC-2382-01EN  
Date of issuance: July 2008  
Issuance responsibility: PFU LIMITED  
Permission to use, copy, modify, and distribute this program for any  
purpose and without fee is hereby granted, provided that this  
copyright and permission notice appear on all copies and supporting  
documentation, the name of Carnegie Mellon not be used in  
advertising or publicity pertaining to distribution of the program  
without specific prior permission, and notice be given in supporting  
documentation that copying and distribution is by permission of  
Carnegie Mellon and Stanford University. Carnegie Mellon makes  
no representations about the suitability of this software for any  
purpose. It is provided "as is" without express or implied warranty.  
z Copying of the contents of this manual in whole or in part and  
copying of the scanner application is forbidden under the copyright  
law.  
z The contents of this manual are subject to change without notice.  
z PFU LIMITED. is not liable whatsoever for any damages resulting  
from use of this scanner and procedures described in this manual,  
profit due to defects, and any claims by a third party.  
WinDump3.9.5  
Copyright © 1999 - 2005 NetGroup, Politecnico di Torino (Italy).  
Copyright © 2005 - 2006 CACE Technologies, Davis (California).  
All rights reserved.  
Redistribution and use in source and binary forms, with or without  
modification, are permitted provided that the following conditions  
are met:  
1. Redistributions of source code must retain the above copyright  
notice, this list of conditions and the following disclaimer.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eizo Computer Monitor IEC60601 1 1 User Manual
Estate Range TEP200VA User Manual
Freedom9 Switch IP 100 User Manual
Furuno SONAR CH 28 User Manual
Fusion Car Speaker EN SW100 User Manual
GE Double Oven JBP89DM User Manual
Gemini Stereo Amplifier GPA 1000 User Manual
GE Oven ZET1SM User Manual
Gianni Industries Door LZ NH2300N User Manual
Gigabyte Network Card GV N57128DE User Manual