Fujitsu Scanner fi 5110C User Manual

P3PC-1072-03EN  
fi-5110C Image Scanner  
Getting Started  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Thank you for purchasing the fi-5110C Duplex Color  
Scanner.  
The use of a shielded interface cable  
is required to comply with the Class B  
limits of Part 15 of FCC rules.  
The length of the AC cable must be 2  
meters (6.6 feet) or less.  
ATTENTION  
This document describes how to handle fi-5110C  
Duplex Color Scannerand basic operation methods.  
Before you start using fi-5110C Duplex Color Scanner,  
be sure to thoroughly read this manual to ensure correct  
use.  
The "Operator’s Guide" is stored on the Setup Disk.  
The guide provides useful and detailed information on  
Operations when you would like to using advanced fea-  
tures, daily maintenance of the scanner, replacement of  
consumables.Please also read the Operator’s Guide for  
your reference.  
Canadian DOC Regulations  
This digital apparatus does not exceed the Class B  
limit for radio noise emissions from digital  
apparatus set out in the Radio interference  
Regulations of the Canadian Department of  
Communications.  
This Class B digital apparatus complies with  
Canadian ICES-003.  
Regulatory Information  
Le présent appareil numérique n'émet pas de  
parasites radioélectriques dépassant les limites  
applicables aux appareils numériques de la classe  
B et prescrites dans le Règlement sur le brouillage  
radioélectrique dictées par le Ministère des  
Communications du Canada.  
FCC declaration  
This equipment has been tested and found to  
comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference in a  
residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and,  
if not installed and used in accordance with the  
instruction manual, may cause harmful  
Cet appareil numérique de la classe B est  
conforme à la norme NMB-003 du Canada.  
Bescheimigung des Herstellers /  
Importeurs  
interference to radio communications. However,  
there is no guarantee that interference will not  
occur in a particular installation. If this equipment  
does cause harmful interference to radio or  
television reception, which can be determined by  
turning the equipment off and on, the user is  
encouraged to try to correct the interference by  
one or more of the following measures:  
Für den fi-5110C wird folgendes bescheinigt:  
In Übereinsstimmung mit den Bestimmungen  
der EN45014(CE) funkentstört  
Maschinenlärminformationsverordnung 3.  
GPSGV: Der höchste Schalldruckpegel beträgt  
70 dB (A) oder weniger, gemäß EN ISO 7779.  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
®
International ENERGY STAR Program  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
located.  
As an ENERGY  
STAR® Partner, PFU  
LIMITED has  
Consult your dealer or an experienced radio/TV  
technician.  
determined that this  
product meets the  
ENERGY STAR®  
guidelines for energy  
efficiency.  
The International ENERGY STAR® Office  
Equipment Program is an international program  
that promotes energy saving through the  
FCC warning: Changes or modifications not  
expressly approved by the party responsible for  
compliance could void the user’s authority to  
operate the equipment.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
penetration of energy efficient computers and  
other office equipment. The program backs the  
development and dissemination of products with  
functions that effectively reduce energy  
consumption. It is an open system in which  
business proprietors can participate voluntarily.  
The targeted products are office equipment such  
as computers, monitors, printers, facsimiles,  
copiers, scanners, and multifunction devices.  
Their standards and logos are uniform among  
participating nations.  
Trademarks  
Microsoft, Windows, and Windows NT are  
registered trademarks of Microsoft Corporation in  
the United States and/or other countries.  
ISIS and QuickScan are trademarks or registered  
trademarks of EMC Corporation in the United  
States.  
Adobe, the Adobe logo, and Acrobat are either  
registered trademarks of Adobe Systems  
Incorporated in the United States and/or other  
countries.  
Use in High-safety Applications  
Other product names are the trademarks or  
registered trademarks of the respective companies.  
This product has been designed and manufactured  
on the assumption that it will be used in office,  
personal, domestic, regular industrial, and  
general-purpose applications. It has not been  
designed and manufactured for use in applications  
(simply called "high-safety applications" from  
here on) that directly involve danger to life and  
health when a high degree of safety is required,  
for example, in the control of nuclear reactions at  
nuclear power facilities, automatic flight control  
of aircraft, air traffic control, operation control in  
mass-transport systems, medical equipment for  
sustaining life, and missile firing control in  
weapons systems, and when provisionally the  
safety in question is not ensured. The user should  
use this product with adopting measures for  
ensuring safety in such high-safety applications.  
PFU LIMITED assumes no liability whatsoever  
for damages arising from use of this product by  
the user in high-safety applications, and for any  
claims or compensation for damages by the user  
or a third party.  
How Trademarks Are Indicated In  
This Manual  
References to operating systems (OS) and  
applications are indicated as follows:  
®
®
Windows 95  
Windows 98  
Windows Me  
Microsoft Windows 95  
operating system  
®
®
Microsoft Windows 98  
operating system.  
®
®
Microsoft Windows  
Millennium Edition operating  
system.  
®
®
Windows NT 4.0  
Microsoft Windows NT 4.0  
Server operating system,  
®
®
Microsoft Windows NT 4.0  
Workstation operating system.  
®
®
Windows 2000  
Windows XP  
Microsoft Windows 2000  
Professional operating system.  
About the Use of Mercury  
®
®
Microsoft Windows XP  
Professional operating system,  
Lamp(s) inside this product contain  
mercury and must be recycled or  
disposed of according to local, state,  
or federal laws.  
®
®
Microsoft Windows XP  
g
H
Home Edition operating system.  
Where there is no distinction between the different  
versions of the above operating system, the  
general term "Windows " is used.  
To avoid unexpected injury, read the following  
carefully.  
Adobe  
Acrobat 7.0  
Adobe® Acrobat® 7.0 Standard  
Doing the following actions may result in serious  
personal injuries:  
Do not put the substance contained in the lamp  
in your mouth as it has mercury.  
Do not breathe the chemical liquid contained in  
the scanner lamps.  
Do not incinerate, crush, or shred the lamps or  
scanner parts.  
fi-5110C Image Scanner Getting Started  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufacturer  
Symbols Used In This Manual  
PFU LIMITED  
This symbol alerts operators to  
particularly important information. Be  
sure to read this information.  
ATTENTION  
International Sales Dept., Imaging Business  
Division, Products Group  
Solid Square East Tower, 580 Horikawa-cho,  
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,  
Japan  
This symbol alerts operators to helpful  
Phone : (81-44) 540-4538  
HINT  
advice regarding operation.  
All Rights Reserved, Copyright© PFU LIMITED 2006  
Note, Liability  
A TRIANGLE symbol indicates that special  
care and attention is required.  
The drawing inside the triangle shows the  
specific caution.  
BEFORE USING THIS PRODUCT, PLEASE  
READ THIS MANUAL CAREFULLY. IF THIS  
PRODUCT IS NOT USED CORRECTLY,  
UNEXPECTED INJURY CAN OCCUR TO  
USERS OR BYSTANDERS.  
A CIRCLE with a diagonal line inside  
shows action which users may not perform.  
The drawing inside or under the circle  
shows the specific action that is not  
allowed.  
Keep this manual in a safe place so that it can be  
easily referred to during use of this product.  
Outline characters on a colored  
background show instructions users should  
follow.  
It may also include a drawing that shows  
the specific instruction.  
While all efforts have been made to ensure the  
accuracy of all information in this manual, PFU  
assumes no liability to any party for any damage  
caused by errors or omissions or by statements of  
any kind in this manual, its updates or  
R
supplements, whether such errors are omissions or  
statements resulting from negligence, accidents,  
or any other cause. PFU further assumes no  
liability arising from the application or use of any  
product or system described herein; nor any  
liability for incidental or consequential damages  
arising from the use of this manual. PFU disclaims  
all warranties regarding the information contained  
herein, whether expressed, implied, or statutory.  
Warning Label  
The glass surface inside the ADF becomes  
hot during the operation. Be careful not to  
touch the glass surface inside the ADF.  
Do NOT remove from the scanner,  
ATTENTION  
stain or scratch the warning labels.  
Warning Indications Used In This  
Manual  
This indication alerts operators  
to an operation that, if not strictly  
observed, may result in severe  
injury or death.  
Screen Examples In This Manual  
The screen examples in this manual are subject to  
change without notice in the interest of product  
improvement. If the actual displayed screen  
differs from the screen examples in this manual,  
operate by following the actual displayed screen  
while referring to the User's Manual of the scanner  
application you are using.  
The screenshots in this manual were captured  
from FUJITSU TWAIN32 scanner driver,  
ScandAll 21 Image Capturing Utility Software,  
This indication alerts operators  
to an operation that, if not strictly  
observed, may result in safety  
hazards to personnel or damage  
to equipment.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FUJITSU ISIS scanner driver, QuickScan™  
image capturing software and Adobe® Acrobat®.  
Wipe any dust from the power plug.  
Wipe off any dust from metal parts on the  
power plug or metal fittings with a soft, dry  
cloth. Accumulated dust can cause fire or  
electric shock.  
About Maintenance  
The user must not perform repairs on this scanner.  
Contact the store where you purchased the scanner  
or an authorized FUJITSU Image Scanner service  
provider to have repairs done on this product.  
Do not install the device in locations  
that has oil smoke, steam, humidity,  
and dust.  
Safety Precautions  
Do not install the scanner in locations  
subject to oil smoke, steam, humidity, and  
dust. Doing so might cause a fire or  
electric shock.  
Turn the scanner OFF if it is damaged.  
Do not damage the AC cable.  
If the scanner is damaged for any reason,  
turn the scanner off and unplug the power  
cable. Contact the store where you  
purchased the scanner.  
A damaged AC cable may cause fire or  
electric shock. Do not place heavy objects  
on AC cables, or pull, bend, twist, heat,  
damage or modify AC cables.  
Do not use damaged AC cables or power  
plugs, or install any cables or power plugs  
to loose wall sockets.  
Do not put liquids inside the scanner.  
Do not insert or drop metal objects in to the  
scanner. Do not scan wet documents or  
documents with paper clips or staples. Do  
not splash or allow the scanner to get wet.  
Use only specified AC cables and  
connector cables.  
If foreign objects (water, small metal  
objects, liquids, etc.) get inside the scanner,  
immediately turn off the scanner and dis-  
connect the power plug from the power out-  
let. Then, contact the store where you  
bought the scanner or the Maintenance Ser-  
vice Center. Pay particular attention to this  
warning in households where there are  
small children.  
Use only specified AC cables and  
connector cables. Failure to use the  
correct cables might cause electric shock  
and/or equipment failure.  
Use this scanner only at the  
indicated power voltage. Do not  
connect to multiple-power strips.  
Use this scanner only at the indicated  
power voltage and current. Improper  
power voltage and current might cause  
fire or electric shock. Do not connect to  
multiple-power strips.  
Do not touch the inside of the  
scanner unless necessary.  
Do not take apart or modify the scanner.  
The inside of the scanner contains high-  
voltage components. Touching these  
components might cause electric shock or  
fire.  
Do not touch the AC cable with wet  
hands.  
Do not touch the power plug with wet  
hands. Doing so might cause electric  
shock.  
fi-5110C Image Scanner Getting Started  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Do not use the scanner if you smell a  
strange odor.  
Avoid any contact when scanner is in  
use.  
If you detect heat coming from the device or  
detect other problems such as smoke,  
strange smells or noises, immediately turn  
off the scanner and then disconnect its  
power plug. Make sure that any smoke  
coming from it has stopped, before  
contacting the store where you bought the  
scanner or an authorized FUJITSU scanner  
service provider.  
Avoid touching any scanner mechanism  
during scanning since this may cause  
injuries.  
Do not use the scanner immediately  
after moving it from a cold place into  
a warm room.  
Do not use the device immediately after  
moving it from a cold place into a warm  
room. Condensation may occur, which  
might lead to scanning errors. Let the  
device dry about one or two hours before  
you use it.  
Do not install the scanner on  
unstable surfaces.  
Make sure that the scanner is installed on  
a flat, level surface and that none of its  
parts extend beyond the surface top, such  
as a desk or table. Do not install the  
scanner on unstable surfaces. Install the  
scanner on a level surface that is free of  
vibration to prevent it from falling.  
Install the scanner on a strong surface that  
will support the weight of the scanner and  
other devices.  
Before moving the scanner,  
disconnect the power plug from the  
power outlet.  
Do not move the scanner with the power  
and interface cables connected as this can  
damage the cables, which can later cause  
fire, electric shock as well as injury.  
Before moving the scanner, be sure to  
disconnect the power plug from the power  
outlet, and all other data cables.  
Make sure that the floor is free of any  
obstructions.  
Do not block the ventilation ports.  
Do not block the ventilation ports. Blocking  
the ventilation ports generates heat inside  
of scanner, which may result in fire or  
scanner failure.  
Protect the scanner from static  
electricity.  
Install the scanner away from strong  
magnetic fields and other sources of  
electronic noise. Also, protect the scanner  
against any static electricity, which can  
cause the scanner to malfunction.  
Do not place heavy objects or climb  
on top of the scanner.  
Do not place heavy objects on the scanner  
or use the scanner's surface top to  
perform other work. Improper installation  
might cause injuries and equipment  
failure.  
Do not use aerosol sprays near the  
scanner.  
Do not use aerosol sprays to clean the  
scanner. Aerosol sprays can blow dirt and  
dust inside the scanner, resulting in scanner  
failure or malfunction.  
Firmly insert the power plug.  
Firmly insert the power plug as far it can  
go into the power outlet.  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disconnect the power plug from the  
power outlet when the scanner is not  
used for a long period of time.  
When the scanner is not going to be used  
for a long period of time, be sure to  
disconnect the power plug from the power  
outlet for safety.  
Do not install the scanner in direct  
sunlight.  
Do not install the scanner under direct  
sunlight or near heating apparatus. Doing so  
might cause excessive heat to build up  
inside the scanner, which can cause  
scanner trouble or even fire. Install the  
scanner in a well-ventilated location.  
fi-5110C Image Scanner Getting Started  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 PREPARING THE SCANNER  
Rear  
1.1 Checking the Contents of  
the Scanner Package  
When you open the scanner package, please handle the  
main unit and its attachments carefully.  
Make sure it contains all the parts listed in the package  
contents list that is included in the package box.  
If any parts are missing or defective, contact your sales  
representative.  
1.2 Names of Parts  
USB Interface  
connector  
Security  
Cable Slot  
DC inlet  
This section describes the scanner parts.  
Front  
Removable Parts  
ADF paper chute  
ADF open lever  
Parts that can be removed from the scanner are dis-  
played below.  
Side guide  
Automatic document  
feeder(ADF)  
ADF paper chute  
Sheet Guide  
Pad ASSY  
Pick Roller  
Operator  
panel  
Stacker  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Indications on the Function  
1.3 Operator Panel  
Number display  
The operator panel is located on the right side of the  
scanner. This panel is comprised of a Function Number  
display, four buttons and a LED.  
8  
Blinks only one time upon turning on the scan-  
ner.  
Function No  
display  
P  
Indicates that the scanner has been turned ON  
and is being initialized.  
Function  
Send to  
0  
Scan  
Indicates that initialization will soon end.  
Power button  
LED  
1  
Indicates that initialization has ended success-  
fully.  
The scanner is now in "Ready Status".  
Name  
Function  
Function Number  
display  
Indicates the function  
Number and error status.  
U  
Indicates that a temporary error occurred when  
documents were being scanned. A number  
appearing in alternation following the U (i.e.,  
1, 2 and 4) refers to the type of error.  
To return the scanner to the ready status ("1"),  
press "Scan" or "Send to" button.  
Button Function  
Changes the Function acti-  
vated by the Send to button  
(*).  
Send to  
Scan  
Launches the linked appli-  
cation software (*).  
E  
Indicates that a device (hardware) alarm has  
occurred during scanning of documents.  
"E" and the alarm Number (2 to 9 and c) will  
appear alternately.  
To return the scanner to the ready status ("1"),  
press "Scan" or "Send to" button.  
If this alarm occurs, turn the power off and on  
again. If the alarm continues after turning the  
power on again, contact your service engineer.  
Power  
button  
Turns the scanner ON and  
OFF.  
LED  
-
Lights when the scanner is  
turned ON.  
*) About the settings on the launcher, refer to  
FUJITSU TWAIN32 scanner driver help and the  
"fi-5110C Operator’s Guide" in the Setup CD-  
ROM.  
fi-5110C Image Scanner Getting Started  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter2 INSTALLATION OF THE SCANNER  
Installing the FUJITSU TWAIN32  
2.1 Installing the Scanner  
Application  
Scanner Driver  
Both the scanner driver and image capturing application  
software (called "application" hereafter) must be  
installed on your PC.  
Windows XP screenshots are used in  
ATTENTION  
this section as examples. The win-  
dows and operations may slightly vary  
depending on your OS.  
There are two types of drivers for scanner, The  
FUJITSU TWAIN 32 Scanner Driver and FUJITSU  
ISIS Scanner Driver, as well as two software applica-  
tions, ScandAll 21 and QuickScan Pro™, are provided  
with this product. The following sections describe how  
to install each driver and application.  
1. Turn on your PC and log on to Windows.  
When using Windows 2000 or Win-  
ATTENTION  
dows XP, log on as a user with  
"Administrator" privileges.  
Please install the scanner driver  
ATTENTION  
before connecting the scanner to your  
PC.  
2. Insert the Setup CD-ROM into the CD drive.  
If you connect the scanner before  
installing the scanner driver, the scan-  
ner will not operate correctly.  
If you have connected the scanner  
beforehand, the "Found New Hard-  
ware Wizard" screen appears (this  
screen might differ slightly according  
to the used OS) . On this screen, click  
the [Cancel] button to close the  
Wizard screen and install the scanner  
driver first.  
<SETUP DISK START UP SCREEN> appears.  
This screen may not appear when the  
ATTENTION  
"Autoplay" setting of your PC is OFF.  
In this case, run "Install.exe" in this  
CD-ROM directly from the "Explorer"  
or "My Computer".  
3. Click [INSTALL PRODUCTS].  
For FUJITSU TWAIN32 Scanner Driver  
Preparation  
Confirm the following items before installing the appli-  
cation.  
Remove the Setup CD-ROM from its package.  
Uninstall any older version of FUJITSU  
TWAIN 32 driver if already installed.  
Uninstall [Scanner Utility for Microsoft  
ATTENTION  
Windows] from [Add/Remove Pro-  
grams] of the control panel.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4. Click [TWAIN Driver] on the window below.  
8. When the [InstallShield Wizard Complete] win-  
dow appears, click [Finish].  
5. Error Recovery Guide Installation window  
appears.  
9. Your computer will be restarted.  
Do not remove the Setup CD-ROM from the CD  
drive until your PC has completely restarted.  
Error Recovery Guide is a software that displays  
troubleshooting information on screen when any  
scanner error occurs. Although this software’s  
installation is highly recommended, the perfor-  
mance of the scanner would not be affected if  
not installed.  
Installation of the scanner driver is completed.  
Installing ScandAll 21  
"Scandall 21" is an image capturing software that com-  
plies with the TWAIN standard. The FUJITSU TWAIN  
32 scanner driver enables you to capture images with a  
FUJITSU image scanner fi-series product.  
When you select [Yes] for installing  
ATTENTION  
the Error Recovery Guide, [Choose  
Setup Language] window appears.  
Select a language and follow the  
instructions on the window. Error  
Recovery Guide will automatically  
continue finishing its installation.  
Please wait until the installation of  
TWAIN driver automatically starts.  
When using Windows 2000 or Win-  
ATTENTION  
dows XP, log on as a user with  
"Administrator" privileges.  
1. Insert the Setup CD-ROM into the CD drive.  
6. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
<SETUP DISK START UP SCREEN> appears.  
2. Click [INSTALL PRODUCTS].  
7. Follow the instructions on the window to install  
the application.  
fi-5110C Image Scanner Getting Started  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Click [ScandAll 21] on the window below.  
For FUJITSU ISIS Scanner Driver  
Preparation  
Remove the Setup CD-ROM from its package.  
Installing the FUJITSU ISIS  
Scanner Driver  
Windows XP screenshots are used in  
ATTENTION  
4. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
this section as examples. The win-  
dows and operations may vary slightly  
depending on your OS.  
1. Turn your PC on and log on to Windows.  
When using Windows 2000 or Win-  
ATTENTION  
dows XP, log on as a user with  
"Administrator" privileges.  
5. Install the application following the instructions  
on the window.  
2. Insert the "Setup CD-ROM" into the CD drive.  
6. When the [InstallShield Wizard Complete] win-  
dow appears, click [Finish].  
<SETUP DISK START UP SCREEN> appears.  
This screen may not appear when the  
ATTENTION  
"Autoplay" setting of your PC is OFF.  
In this case, run "Install.exe" in this  
CD-ROM directly from the "Explorer"  
or "My Computer".  
3. Click [INSTALL PRODUCTS].  
For finishing the installation, it may be  
ATTENTION  
necessary to restart your computer.  
Follow the instructions on the window.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Click [ISIS Driver] on the window below.  
Installing QuickScan Pro™  
"QuickScan Pro™" is an image capturing software that  
complies with the ISIS standard. The FUJITSU ISIS  
scanner driver enables you to capture images with a  
FUJITSU image scanner fi-series product  
When using Windows 2000 or Win-  
ATTENTION  
dows XP, log on as a user with  
"Administrator" privileges.  
If an older version of QuickScan has  
already been installed on your PC,  
uninstall it before installing this ver-  
sion.  
5. Error Recovery Guide Installation window  
appears.  
1. Insert the Setup CD-ROM into a CD drive.  
Error Recovery Guide is a software that displays  
troubleshooting information on screen if any  
scanner error occurs. Although this software’s  
installation is highly recommended, the perfor-  
mance of the scanner would not be affected if  
not installed.  
<SETUP DISK STARTUP SCREEN> appears.  
2. Click [INSTALL PRODUCTS].  
When you select [Yes] for installing  
ATTENTION  
Error Recovery Guide, the [Choose  
Setup Language] window appears.  
Select a language and follow the  
instructions on the window. The Error  
Recovery Guide will automatically  
continue finishing its installation.  
Please wait until the installation of  
ISIS driver automatically starts.  
6. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
3. Click [QuickScan PRO (Trial)] on the window  
below.  
7. Follow the instructions on the window to install  
the application.  
8. When the [InstallShield Wizard Complete]  
window appears, click [Finish].  
4. Continue to install the application following the  
instructions on the window.  
9. Your computer will be restarted. Do not remove  
the Setup CD-ROM from the CD drive until your  
PC has completely restarted.  
Now the installation of the scanner driver is completed.  
fi-5110C Image Scanner Getting Started  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Insert the Setup CD-ROM in your CD drive.  
The <SETUP DISK STARTUP SCREEN> will  
appear.  
2. Click [Install Products].  
5. Enter the required information, then click  
[Next >] button.  
3. Click [Error Recovery Guide] on the next screen.  
"QuickScan Pro™" included in the  
ATTENTION  
Setup CD-ROM is an evaluation ver-  
sion. For further use after the expira-  
tion of its evaluation period of up to 30  
launches, it is necessary to purchase  
a fully functional version of QuickScan  
Pro™. (When you install the evalua-  
tion version, do not change the Serial  
Number already displayed.)  
4. Select a language to use for the installation in  
the <Choose Setup Language> window and  
click [OK].  
6. Install the application following the instructions  
on the window.  
5. Install the application following the instructions  
in the window.  
Error Recovery Guide  
If you did not install together the Error Recovery Guide  
with the driver, please proceed with the procedures  
given below for installing it.  
Error Recovery Guide is a software that displays trou-  
bleshooting information on screen if any scanner error  
occurs.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. When the [InstallShield Wizard Complete]  
screen displays, click [Finish].  
This window is not displayed aou-  
tomatically when the "Auto play" set-  
ting of your computer is deactivated.  
In this case, please run "Auto  
ATTENTION  
play.exe" of this CD-ROM directly  
using the "Explore" or "My computer".  
2. Select the language and Click [OK] button.  
Image Processing Software Option  
(Trial)  
To install the image processing software option (trial  
version) , please refer to the "Image Processing Software  
Option User's Guide".  
3. Select "Install Adobe Acrobat 7.0 Standard".  
®
®
Adobe Acrobat  
Install Adobe Acrobat from the "Adobe Acrobat 7.0  
CD-ROM" provided with this scanner.  
Adobe Acrobat 7.0 Standard is not  
ATTENTION  
supported by Microsoft Windows 95,  
Microsoft Windows 98/98SE,  
Microsoft Windows NT4.0, Microsoft  
Windows Me.  
4. Click the [Next] button. The set up window  
appears.  
Adobe Acrobat is required for display-  
HINT  
ing the manuals stored in the CD-  
ROM.  
* Installation of Adobe Acrobat 7.0 is  
not necessary if it has already been  
installed in your PC.  
1. Insert the "Adobe Acrobat 7.0 CD-ROM" into the  
CD-ROM drive.  
The "Adobe Acrobat 7.0 Standard - Setup" win-  
dow appears.  
fi-5110C Image Scanner Getting Started  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Follow the instructions to install the software.  
Select "How to install" on the "Adobe  
Support and User registration for  
Adobe products:  
ATTENTION  
Refer to the technical support informa-  
tion stored in the [Customer Support]  
folder on Adobe Acrobat 7.0 Standard  
CD-ROM. (Note that free person-to-  
person support is not available for this  
bundled product.)  
HINT  
Acrobat 7.0 Standard" window to learn  
more about Adobe Acrobat 7.0 installa-  
tion. Refer to "Adobe Acrobat Help"  
about how to use Adobe Acrobat7.0.  
Notes for using Adobe Acrobat 7.0  
ATTENTION  
When scanning a paper document  
and converting the image to PDF  
using Acrobat 7.0, unexpected images  
may be output when:  
2.2 Installing the Scanner  
After the computer has been restarted, connect the scan-  
ner.  
1. Setting "Edge Shadow Removal" in  
Acrobat, and setting "Digital  
Endorser" or "Black Background"  
options in the TWAIN driver at the  
same time. Letter strings embed-  
ded in the image or the background  
may be missed.  
1. Place the scanner at its installation site.  
For details on the scanner's dimensions and required  
installation space, refer to "fi-5110C Operator’s  
Guide" "9.2 Installation Specifications" in the Setup  
CD-ROM.  
Solution 1: Set "Edge shadow  
removal" to "OFF" or set any option  
other than "Adaptive" for  
"Color/Grayscale" and/or "Mono-  
chrome" under "Compression" by  
selecting [File]->[Create PDF]->  
[From Scanner...]-> [Image Set-  
tings...] in Acrobat.  
2. Attach the ADF Paper Chute.  
Hold the ADF paper chute and insert its tabs into the  
corresponding slots in the scanner as shown in the  
figure below.  
The Side guides of the ADF paper chute have to face  
up.  
Solution 2: Adjust the scanning  
density in the TWAIN driver.  
ADF paper chute  
2. Setting "Adaptive" for "Color/Gray-  
scale" and/or "Monochrome" under  
"Compression" in Acrobat and  
scanning in a resolution lower than  
the resolution recommended for  
Acrobat.  
Tab  
Solution: Set OPTION to some-  
thing other than "Adaptive" under  
"Compression."  
3. Scanning a document longer than  
the double letter (11x17) or A3 size,  
when setting "Overscan" in the  
TWAIN driver, the scan may fail.  
Solution: When scanning a double  
letter (11x17) or A3 size of docu-  
ment, do not set "Overscan" in  
TWAIN driver.  
Side guide  
*As for detailed usage and information  
of Acrobat, refer to "Create a PDF file  
from a scanned document" in Acrobat  
Help.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3. Connect the AC adapter.  
2.3 Connecting the USB Cable  
Follow the procedure below to connect the USB cable.  
Use only the AC adapter provided by  
the manufacturer.  
ATTENTION  
1. Connect the USB interface cable to the USB  
interface connector.  
1) Connect the AC cable to the AC adapter.  
2) Connect the AC adapter connector to the  
scanner’s DC inlet.  
2. Connect the other end of the USB interface  
cable to the PC.  
Be sure to use the USB cable which  
ATTENTION  
comes as an accessory with this  
scanner.  
Correct operation with commercially  
available cables is not guaranteed.  
When connecting to an USB hub,  
use the first stage USB hub that is  
closest to the computer. If you use  
the second or later hub stages, the  
scanner may not operate correctly.  
3) Plug the AC cable into the outlet.  
3. Press the power button to turn ON the scanner.  
Your scanner will be automatically detected.  
The Function Number Display and the  
LED may flash for an instant when  
plugging the AC cable into the scanner.  
HINT  
For Windows 98:  
When a request for inserting the CD-ROM for  
Windows 98 appears, insert it into the CD drive and  
click the [OK] button.  
For Windows 2000:  
When [Digital Signature not Found] appears, click  
[Yes].  
The installation of the scanner is completed.  
fi-5110C Image Scanner Getting Started  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6. Set scanning resolution, document size, etc. on  
the [TWAIN driver] window (for setting details of  
scanning) and click the [Scan] button.  
2.4 Confirming Installation  
To confirm whether the installation was successful, per-  
form a scanning operation with an application that com-  
plies with either the TWAIN regulations, such as  
ScandAll 21 or the ISIS regulations such as QuickScan  
ProTM  
.
Confirming with ScandAll 21  
1. Load the documents on the scanner.  
For details on loading documents, refer to "2.2 Load-  
ing Documents on the ADF for Scanning" in the fi-  
5110C Operator's Guide on the Setup CD-ROM.  
2. Start ScandAll21.  
Select [Start] - [Programs] - [Scanner Utility for  
Microsoft Windows] - [ScandAll 21].  
For details on [TWAIN driver], refer to  
the "FUJITSU TWAIN32 Scanner  
HINT  
Driver User’s Guide" provided in the  
Setup CD-ROM.  
3. Specify the scanner (that you will use)  
Select [Select Source...]from the [Scan] menu of  
ScandAll 21.  
7. Documents are scanned, and the scanned  
images are displayed on the [ScandAll 21] win-  
dow.  
4. Select "FUJITSU fi-5110Cdj" on the dialog box.  
If the scanning completes without any trouble, the  
installation performed successfully.  
5. Select [To View...] from the [Scan] menu.  
For details on various types of scanning, refer to the  
"fi-5110C Operator’s Guide" on the Setup CD-ROM.  
Confirming with QuickScan Pro™  
1. Load the documents on to the scanner.  
For details on loading documents, refer to "2.2 Load-  
ing Documents on the ADF for Scanning" in the fi-  
5110C Operator's Guide on the Setup CD-ROM.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. Start QuickScan Pro™.  
Refer to "QuickScan Overview" or  
"QuickScan Help" for information about  
QuickScan Pro™ functions and opera-  
tions. On the [Start] menu, point to  
[Programs]-[QuickScan] and click the  
file.  
From the [Start] menu, select [Programs]-[Quick-  
Scan]-[QuickScan].  
HINT  
3. Select [Select Scanner...] from [Scan] menu in  
QuickScan Pro™.  
And, select fi-5110C from the list of [Scanner:], and  
then click the [OK] button.  
4. Select [Preview Settings...] from the [Scan]  
menu. Set the scan resolution, paper size and  
other scanning requirements, and then click  
[OK].  
5. Select [Preview Scan] from the [Scan] menu.  
And then the document is scanned.  
If the scanning completes without any trouble, the  
installation performed successfully.  
fi-5110C Image Scanner Getting Started  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix 1 TROUBLESHOOTING  
Troubleshooting checklist  
Symptom  
Check this item  
Remedy  
Scanner does not turn  
on.  
Have you pressed the power  
button on?  
Push the power button in to turn the scan-  
ner.  
Are the AC cable and AC adapter  
properly connected to the scan-  
ner?  
Correctly connect the AC cable and the AC  
adapter.  
Disconnect the AC cable and the AC  
adapter from the scanner, then connect  
them again.  
If this does not restore the power supply,  
contact the store where you purchased the  
scanner or an authorized FUJITSU scanner  
service provider.  
Are you using the correct AC cable You must use the AC adapter and cable  
and AC adapter supplied with the  
scanner from the manufacture?  
supplied with your scanner by the  
manufacture. Please get the correct AC  
adapter and cable to connect to your scan-  
ner.  
Scanning does not  
commence.  
Are the documents loaded properly Realign and reload the documents on to  
on to the ADF paper chute?  
ADF paper chute.  
Is the ADF closed completely?  
Close the ADF completely.  
Is the USB cable cable connected Connect the cable. (When a USB hub is  
securely? used, check the hub's power supply.)  
Does the Function Number display When the Function Number display indi-  
indicates an alarm or an error?  
cates an alarm or an error, refer to "Chap-  
ter 6 TROUBLESHOOTING" in the fi-  
5110C Operator’s Guide for removing the  
alarm or the error.  
The alarm status remain displayed Turn off and on the power button.  
even after the scanner has been  
turned off and on again?  
If this does not eliminate the alarm status,  
contact the store where you purchased the  
scanner or an authorized FUJITSU scanner  
service provider.  
Vertical lines appear in  
the printed image.  
Is the glass dirty?  
Clean the glass as instructed in the Opera-  
tor's Guide "4. Daily Care".  
The scanned printed  
Have the documents been loaded  
Reload the documents correctly.  
image appears shifted or correctly?  
distorted.  
Quality of the scanned  
image is not satisfactory.  
Is the glass clean?  
Clean glass and otther dirty locations  
around glass and ADF.  
AP-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Symptom  
Check this item  
Remedy  
Paper frequently multi  
feeds.  
Have the document requirements  
of the fi-5110C Operator’s Guide’s  
"Document Quality" and the "multi  
Use document conditions that meet the  
"Document Quality" and the "Multi Feed  
Detection Conditions" in chapter 7 of the fi-  
feed Detection Conditions" of chap- 5110C Operator’s Guide.  
ter 7 been satisfied?  
Are the documents placed properly Fan the documents before scanning. Cor-  
in the ADF paper chute?  
rectly align the document stack and load  
them on the ADF paper chute. Refer to "2.2  
details.  
Is the stack of document thicker  
than 5 mm?  
Reduce the number of sheets of the stack  
to a thickness of 5 mm or less.  
Is the Pad ASSY dirty?  
Clean the Pad ASSY. Refer to Operator's  
Guide in "Chapter 4 Daily Care".  
Is the Pad ASSY worn out?  
Replace the Pad ASSY. Refer to Opera-  
tor's Guide in "5.2. Replacing the Pad  
ASSY".  
Paper does not feed  
(pick error occurs fre-  
quently, or document  
stops midway).  
Have the document requirements  
of the fi-5110C Operator’s Guide’s  
"Document Quality" and the "Multi  
Feed Detection Conditions" of  
Use document conditions that meet the  
"Document Quality" and the "Multi Feed  
Detection Conditions" in the chapter 7 of  
the fi-5110C Operator’s Guide.  
chapter 7 been satisfied?  
Is the Pick roller dirty?  
To clean the pick roller, refer to Operator's  
Guide in "Chapter 4 Daily Care".  
Is the Pick roller worn out?  
Change the Pick roller. Refer to Operator's  
Guide in "5.3. Replacing the Pick Roller".  
Is there any dirt or dust in the docu- Remove any dirt or dust from the docu-  
ment feed path?  
ment feed path.  
Are the scanned images Are the Feed rollers dirty?  
elongated?  
Clean the Feed rollers. Refer to Operator's  
Guide in "Chapter 4 Daily Care".  
Have you adjusted the scan scale? Select "Scanners and Cameras" in the con-  
trol panel, then click the [Device Set] tab to  
adjust scale.  
Is there a shadow on the Are the Feed rollers dirty?  
Clean the Feed rollers. Refer to Operator's  
Guide in "Chapter 4 Daily Care".  
top or bottom edge of  
the scanned image?  
Is the offset adjusted?  
On [Scanners and Cameras] in the control  
panel, adjust the [Sub-scan Setting] (in  
case there is a shadow in the top edge) or  
adjust the [Bottom] (in case there is a  
shadow in the bottom edge).  
fi-5110C Image Scanner Getting Started  
AP-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temporary error  
Device alarm (Non-Temporary error)  
Indication  
Meaning  
Paper feed error  
Multi Feed error  
Indication  
Meaning  
U1  
U2  
U4  
E2  
E3  
E4  
E6  
E7  
E9  
Ec  
Trouble in the optical system (front).  
Trouble in the optical system (back).  
The motor’s fuse has blown out.  
Trouble with the operator panel.  
Trouble occurred with the EEPROM.  
An error in the image memory.  
An alarm in the memory.  
The ADF has been opened during  
scanning.  
To troubleshoot the indicated errors above:  
"U1" error  
Remove all jammed documents.  
Confirm that the documents meet the paper condi-  
tions for scanning.  
Refer to fi-5110C Operator’s Guide "7.2 Document  
Quality" on the Setup CD-ROM.  
When you encounter any alarm on the display, turn  
the scanner off and on. If the alarm is still displayed  
on the Function Number display, contact the store  
where you purchased the scanner or an authorized  
FUJITSU scanner service provider.  
"U2" error  
Remove all jammed documents.  
Confirm that the documents are within the required  
paper preconditions for scanning.  
Refer to fi-5110C Operator’s Guide "7.2 Document  
Quality" on the Setup CD-ROM.  
"U4" error  
Close the ADF cover completely. For the details,  
refer to "6 TROUBLESHOOTING" in the "fi-  
5110C Operator's Guide" on the Setup CD-ROM.  
AP-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix 2 DAILY CARE  
Parts to Clean and When  
When operating the scanner, the  
ADF’s inside glass becomes  
very hot.  
Part to clean  
Standard Cleaning Cycle  
Before you clean inside the  
scanner, turn off its power and  
unplug the AC adapter from the  
outlet. Wait for at least  
15 minutes.  
Pad ASSY  
Pick roller  
Feed rollers  
Plastic rollers  
Glass  
Clean these parts after every  
1,000 scans.  
Do not turn off the scanner when  
you clean the Feed rollers or  
Eject rollers.  
Cleaning Materials  
The scanner must be cleaned  
ATTENTION  
frequently if you scan any of the  
following type of paper sheets:  
Documents of coated paper  
Documents that are almost completely  
covered with printed text or graphics  
Chemically treated documents such as  
carbonless paper  
Cleaning  
Materials  
Parts  
Remarks  
Number  
Cleaner F1  
(or isopropyl  
alcohol)  
CA99501- 1 bottle  
0013 Moisten the cloth  
with this fluid and  
wipe the scanner  
clean.(*)  
Documents containing a large amount  
of calcium carbonate  
Handwritten documents  
Lint-free dry  
cloth  
Commercially available one  
* For details about cleaning materials, contact the  
FUJITSU scanner dealer where you purchased the  
scanner.  
For details on the cleaning the ADF, refer to "Chapter 4  
Daily Care" in fi-5110C Operator’s Guide in the Setup  
CD-ROM".  
Cleaning Method  
The ADF must be cleaned with a lint-free cloth  
moistened with the Cleaner F1.  
Do not use aerosol sprays to clean  
ATTENTION  
the scanner. Aerosol sprays can blow  
dirt and dust inside the scanner,  
resulting in scanner failure or  
malfunction.  
fi-5110C Image Scanner Getting Started  
AP-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix 3 REPLACING CONSUMABLES  
The illustration below demonstrates the locations of the  
During its operation, the inside  
glass of the ADF becomes very  
hot .  
replacement parts. Refer to "Chapter 5 Replacing  
Consumables" fi-5110C Operator’s Guide on the Setup  
CD-ROM.  
Before replacing the  
consumables, turn the scanner  
off and unplug the AC adapter  
from the outlet. Wait at least  
15 minutes.  
Replacing the Pad ASSY  
Consumables and Replacement  
Cycles  
Below are specifications of consumable items and  
their recommended replacement cycles.  
Replacing the Pick Roller  
Standard  
Parts  
Description  
Pad ASSY  
Pick roller  
Replacement  
Cycle  
Number  
PA03360-  
0002  
After 50,000 scans  
or one year  
PA03360-  
0001  
After 100,000  
scans or one year  
To purchase consumables, contact the store where you  
purchased the scanner or an authorized FUJITSU scan-  
ner service provider.  
Pick Roller Bushing  
Pick Roller Shaft  
The replacement cycles above are rough guidelines  
when using A4 or Letter woodfree or wood containing  
paper 64 g/m2 (17 lb). This cycle varies according to the  
type of paper and how frequently the scanner is used and  
cleaned.  
Use only the consumables specified  
ATTENTION  
by PFU Limited.  
Pick Roller Shaft  
Pick Roller  
AP-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
fi-5110C Image Scanner Getting Started  
P3PC-1072-03EN  
Date of issuance: June, 2006  
Issuance responsibility: PFU LIMITED  
Printed in China  
z Copying of the contents of this manual in whole or in part and  
copying of the scanner application is forbidden under the copyright  
law.  
z The contents of this manual are subject to change without notice.  
z PFU LIMITED. is not liable whatsoever for any damages resulting  
from use of this scanner and procedures described in this manual,  
profit due to defects, and any claims by a third party.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Electro Voice Microphone RE98 User Manual
ETA Systems Surge Protector ETA PD8 User Manual
Fisher Paykel Dishwasher DW60DOX User Manual
Fisher Price Car Seat T3643 User Manual
FoodSaver Food Saver 18 0163 User Manual
Gefen Switch GTB HDKVM ELR User Manual
GE Microwave Oven 164D2966P147 User Manual
GE Monogram GPS Receiver ZV881WSS User Manual
GE Monogram Range JBP64 User Manual
GE Range 164D3333P200 3 User Manual