INTRODUCTION
Thank you for purchasing the fi-5110C Duplex Color
Scanner.
The use of a shielded interface cable
is required to comply with the Class B
limits of Part 15 of FCC rules.
The length of the AC cable must be 2
meters (6.6 feet) or less.
ATTENTION
This document describes how to handle fi-5110C
Duplex Color Scannerand basic operation methods.
Before you start using fi-5110C Duplex Color Scanner,
be sure to thoroughly read this manual to ensure correct
use.
The "Operator’s Guide" is stored on the Setup Disk.
The guide provides useful and detailed information on
Operations when you would like to using advanced fea-
tures, daily maintenance of the scanner, replacement of
consumables.Please also read the Operator’s Guide for
your reference.
Canadian DOC Regulations
This digital apparatus does not exceed the Class B
limit for radio noise emissions from digital
apparatus set out in the Radio interference
Regulations of the Canadian Department of
Communications.
This Class B digital apparatus complies with
Canadian ICES-003.
■ Regulatory Information
Le présent appareil numérique n'émet pas de
parasites radioélectriques dépassant les limites
applicables aux appareils numériques de la classe
B et prescrites dans le Règlement sur le brouillage
radioélectrique dictées par le Ministère des
Communications du Canada.
FCC declaration
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation. This equipment generates,
uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the
instruction manual, may cause harmful
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
Bescheimigung des Herstellers /
Importeurs
interference to radio communications. However,
there is no guarantee that interference will not
occur in a particular installation. If this equipment
does cause harmful interference to radio or
television reception, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
Für den fi-5110C wird folgendes bescheinigt:
•In Übereinsstimmung mit den Bestimmungen
der EN45014(CE) funkentstört
•Maschinenlärminformationsverordnung 3.
GPSGV: Der höchste Schalldruckpegel beträgt
70 dB (A) oder weniger, gemäß EN ISO 7779.
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment
and receiver.
®
International ENERGY STAR Program
•Connect the equipment into an outlet on a circuit
different from that to which the receiver is
located.
As an ENERGY
STAR® Partner, PFU
LIMITED has
•Consult your dealer or an experienced radio/TV
technician.
determined that this
product meets the
ENERGY STAR®
guidelines for energy
efficiency.
The International ENERGY STAR® Office
Equipment Program is an international program
that promotes energy saving through the
FCC warning: Changes or modifications not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
penetration of energy efficient computers and
other office equipment. The program backs the
development and dissemination of products with
functions that effectively reduce energy
consumption. It is an open system in which
business proprietors can participate voluntarily.
The targeted products are office equipment such
as computers, monitors, printers, facsimiles,
copiers, scanners, and multifunction devices.
Their standards and logos are uniform among
participating nations.
Trademarks
Microsoft, Windows, and Windows NT are
registered trademarks of Microsoft Corporation in
the United States and/or other countries.
ISIS and QuickScan are trademarks or registered
trademarks of EMC Corporation in the United
States.
Adobe, the Adobe logo, and Acrobat are either
registered trademarks of Adobe Systems
Incorporated in the United States and/or other
countries.
Use in High-safety Applications
Other product names are the trademarks or
registered trademarks of the respective companies.
This product has been designed and manufactured
on the assumption that it will be used in office,
personal, domestic, regular industrial, and
general-purpose applications. It has not been
designed and manufactured for use in applications
(simply called "high-safety applications" from
here on) that directly involve danger to life and
health when a high degree of safety is required,
for example, in the control of nuclear reactions at
nuclear power facilities, automatic flight control
of aircraft, air traffic control, operation control in
mass-transport systems, medical equipment for
sustaining life, and missile firing control in
weapons systems, and when provisionally the
safety in question is not ensured. The user should
use this product with adopting measures for
ensuring safety in such high-safety applications.
PFU LIMITED assumes no liability whatsoever
for damages arising from use of this product by
the user in high-safety applications, and for any
claims or compensation for damages by the user
or a third party.
How Trademarks Are Indicated In
This Manual
References to operating systems (OS) and
applications are indicated as follows:
®
®
Windows 95
Windows 98
Windows Me
Microsoft Windows 95
operating system
®
®
Microsoft Windows 98
operating system.
®
®
Microsoft Windows
Millennium Edition operating
system.
®
®
Windows NT 4.0
Microsoft Windows NT 4.0
Server operating system,
®
®
Microsoft Windows NT 4.0
Workstation operating system.
®
®
Windows 2000
Windows XP
Microsoft Windows 2000
Professional operating system.
About the Use of Mercury
®
®
Microsoft Windows XP
Professional operating system,
Lamp(s) inside this product contain
mercury and must be recycled or
disposed of according to local, state,
or federal laws.
®
®
Microsoft Windows XP
g
H
Home Edition operating system.
Where there is no distinction between the different
versions of the above operating system, the
general term "Windows " is used.
To avoid unexpected injury, read the following
carefully.
Adobe
Acrobat 7.0
Adobe® Acrobat® 7.0 Standard
Doing the following actions may result in serious
personal injuries:
•Do not put the substance contained in the lamp
in your mouth as it has mercury.
•Do not breathe the chemical liquid contained in
the scanner lamps.
•Do not incinerate, crush, or shred the lamps or
scanner parts.
fi-5110C Image Scanner Getting Started
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Manufacturer
Symbols Used In This Manual
PFU LIMITED
This symbol alerts operators to
particularly important information. Be
sure to read this information.
ATTENTION
International Sales Dept., Imaging Business
Division, Products Group
Solid Square East Tower, 580 Horikawa-cho,
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,
Japan
This symbol alerts operators to helpful
Phone : (81-44) 540-4538
HINT
advice regarding operation.
All Rights Reserved, Copyright© PFU LIMITED 2006
■ Note, Liability
A TRIANGLE symbol indicates that special
care and attention is required.
The drawing inside the triangle shows the
specific caution.
BEFORE USING THIS PRODUCT, PLEASE
READ THIS MANUAL CAREFULLY. IF THIS
PRODUCT IS NOT USED CORRECTLY,
UNEXPECTED INJURY CAN OCCUR TO
USERS OR BYSTANDERS.
A CIRCLE with a diagonal line inside
shows action which users may not perform.
The drawing inside or under the circle
shows the specific action that is not
allowed.
Keep this manual in a safe place so that it can be
easily referred to during use of this product.
Outline characters on a colored
background show instructions users should
follow.
It may also include a drawing that shows
the specific instruction.
While all efforts have been made to ensure the
accuracy of all information in this manual, PFU
assumes no liability to any party for any damage
caused by errors or omissions or by statements of
any kind in this manual, its updates or
R
supplements, whether such errors are omissions or
statements resulting from negligence, accidents,
or any other cause. PFU further assumes no
liability arising from the application or use of any
product or system described herein; nor any
liability for incidental or consequential damages
arising from the use of this manual. PFU disclaims
all warranties regarding the information contained
herein, whether expressed, implied, or statutory.
Warning Label
The glass surface inside the ADF becomes
hot during the operation. Be careful not to
touch the glass surface inside the ADF.
Do NOT remove from the scanner,
ATTENTION
stain or scratch the warning labels.
Warning Indications Used In This
Manual
This indication alerts operators
to an operation that, if not strictly
observed, may result in severe
injury or death.
Screen Examples In This Manual
The screen examples in this manual are subject to
change without notice in the interest of product
improvement. If the actual displayed screen
differs from the screen examples in this manual,
operate by following the actual displayed screen
while referring to the User's Manual of the scanner
application you are using.
The screenshots in this manual were captured
from FUJITSU TWAIN32 scanner driver,
ScandAll 21 Image Capturing Utility Software,
This indication alerts operators
to an operation that, if not strictly
observed, may result in safety
hazards to personnel or damage
to equipment.
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
FUJITSU ISIS scanner driver, QuickScan™
image capturing software and Adobe® Acrobat®.
Wipe any dust from the power plug.
Wipe off any dust from metal parts on the
power plug or metal fittings with a soft, dry
cloth. Accumulated dust can cause fire or
electric shock.
About Maintenance
The user must not perform repairs on this scanner.
Contact the store where you purchased the scanner
or an authorized FUJITSU Image Scanner service
provider to have repairs done on this product.
Do not install the device in locations
that has oil smoke, steam, humidity,
and dust.
■ Safety Precautions
Do not install the scanner in locations
subject to oil smoke, steam, humidity, and
dust. Doing so might cause a fire or
electric shock.
Turn the scanner OFF if it is damaged.
Do not damage the AC cable.
If the scanner is damaged for any reason,
turn the scanner off and unplug the power
cable. Contact the store where you
purchased the scanner.
A damaged AC cable may cause fire or
electric shock. Do not place heavy objects
on AC cables, or pull, bend, twist, heat,
damage or modify AC cables.
Do not use damaged AC cables or power
plugs, or install any cables or power plugs
to loose wall sockets.
Do not put liquids inside the scanner.
Do not insert or drop metal objects in to the
scanner. Do not scan wet documents or
documents with paper clips or staples. Do
not splash or allow the scanner to get wet.
Use only specified AC cables and
connector cables.
If foreign objects (water, small metal
objects, liquids, etc.) get inside the scanner,
immediately turn off the scanner and dis-
connect the power plug from the power out-
let. Then, contact the store where you
bought the scanner or the Maintenance Ser-
vice Center. Pay particular attention to this
warning in households where there are
small children.
Use only specified AC cables and
connector cables. Failure to use the
correct cables might cause electric shock
and/or equipment failure.
Use this scanner only at the
indicated power voltage. Do not
connect to multiple-power strips.
Use this scanner only at the indicated
power voltage and current. Improper
power voltage and current might cause
fire or electric shock. Do not connect to
multiple-power strips.
Do not touch the inside of the
scanner unless necessary.
Do not take apart or modify the scanner.
The inside of the scanner contains high-
voltage components. Touching these
components might cause electric shock or
fire.
Do not touch the AC cable with wet
hands.
Do not touch the power plug with wet
hands. Doing so might cause electric
shock.
fi-5110C Image Scanner Getting Started
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Do not use the scanner if you smell a
strange odor.
Avoid any contact when scanner is in
use.
If you detect heat coming from the device or
detect other problems such as smoke,
strange smells or noises, immediately turn
off the scanner and then disconnect its
power plug. Make sure that any smoke
coming from it has stopped, before
contacting the store where you bought the
scanner or an authorized FUJITSU scanner
service provider.
Avoid touching any scanner mechanism
during scanning since this may cause
injuries.
Do not use the scanner immediately
after moving it from a cold place into
a warm room.
Do not use the device immediately after
moving it from a cold place into a warm
room. Condensation may occur, which
might lead to scanning errors. Let the
device dry about one or two hours before
you use it.
Do not install the scanner on
unstable surfaces.
Make sure that the scanner is installed on
a flat, level surface and that none of its
parts extend beyond the surface top, such
as a desk or table. Do not install the
scanner on unstable surfaces. Install the
scanner on a level surface that is free of
vibration to prevent it from falling.
Install the scanner on a strong surface that
will support the weight of the scanner and
other devices.
Before moving the scanner,
disconnect the power plug from the
power outlet.
Do not move the scanner with the power
and interface cables connected as this can
damage the cables, which can later cause
fire, electric shock as well as injury.
Before moving the scanner, be sure to
disconnect the power plug from the power
outlet, and all other data cables.
Make sure that the floor is free of any
obstructions.
Do not block the ventilation ports.
Do not block the ventilation ports. Blocking
the ventilation ports generates heat inside
of scanner, which may result in fire or
scanner failure.
Protect the scanner from static
electricity.
Install the scanner away from strong
magnetic fields and other sources of
electronic noise. Also, protect the scanner
against any static electricity, which can
cause the scanner to malfunction.
Do not place heavy objects or climb
on top of the scanner.
Do not place heavy objects on the scanner
or use the scanner's surface top to
perform other work. Improper installation
might cause injuries and equipment
failure.
Do not use aerosol sprays near the
scanner.
Do not use aerosol sprays to clean the
scanner. Aerosol sprays can blow dirt and
dust inside the scanner, resulting in scanner
failure or malfunction.
Firmly insert the power plug.
Firmly insert the power plug as far it can
go into the power outlet.
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
Disconnect the power plug from the
power outlet when the scanner is not
used for a long period of time.
When the scanner is not going to be used
for a long period of time, be sure to
disconnect the power plug from the power
outlet for safety.
Do not install the scanner in direct
sunlight.
Do not install the scanner under direct
sunlight or near heating apparatus. Doing so
might cause excessive heat to build up
inside the scanner, which can cause
scanner trouble or even fire. Install the
scanner in a well-ventilated location.
fi-5110C Image Scanner Getting Started
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1 PREPARING THE SCANNER
■ Rear
1.1 Checking the Contents of
the Scanner Package
When you open the scanner package, please handle the
main unit and its attachments carefully.
Make sure it contains all the parts listed in the package
contents list that is included in the package box.
If any parts are missing or defective, contact your sales
representative.
1.2 Names of Parts
USB Interface
connector
Security
Cable Slot
DC inlet
This section describes the scanner parts.
■ Front
■ Removable Parts
ADF paper chute
ADF open lever
Parts that can be removed from the scanner are dis-
played below.
Side guide
Automatic document
feeder(ADF)
ADF paper chute
Sheet Guide
Pad ASSY
Pick Roller
Operator
panel
Stacker
1
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Indications on the Function
1.3 Operator Panel
Number display
The operator panel is located on the right side of the
scanner. This panel is comprised of a Function Number
display, four buttons and a LED.
■ 8
Blinks only one time upon turning on the scan-
ner.
Function No
display
■ P
Indicates that the scanner has been turned ON
and is being initialized.
Function
Send to
■ 0
Scan
Indicates that initialization will soon end.
Power button
LED
■ 1
Indicates that initialization has ended success-
fully.
The scanner is now in "Ready Status".
Name
Function
Function Number
display
Indicates the function
Number and error status.
■ U
Indicates that a temporary error occurred when
documents were being scanned. A number
appearing in alternation following the U (i.e.,
1, 2 and 4) refers to the type of error.
To return the scanner to the ready status ("1"),
press "Scan" or "Send to" button.
Button Function
Changes the Function acti-
vated by the Send to button
(*).
Send to
Scan
Launches the linked appli-
cation software (*).
■ E
Indicates that a device (hardware) alarm has
occurred during scanning of documents.
"E" and the alarm Number (2 to 9 and c) will
appear alternately.
To return the scanner to the ready status ("1"),
press "Scan" or "Send to" button.
If this alarm occurs, turn the power off and on
again. If the alarm continues after turning the
power on again, contact your service engineer.
Power
button
Turns the scanner ON and
OFF.
LED
-
Lights when the scanner is
turned ON.
*) About the settings on the launcher, refer to
FUJITSU TWAIN32 scanner driver help and the
"fi-5110C Operator’s Guide" in the Setup CD-
ROM.
fi-5110C Image Scanner Getting Started
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter2 INSTALLATION OF THE SCANNER
■ Installing the FUJITSU TWAIN32
2.1 Installing the Scanner
Application
Scanner Driver
Both the scanner driver and image capturing application
software (called "application" hereafter) must be
installed on your PC.
Windows XP screenshots are used in
ATTENTION
this section as examples. The win-
dows and operations may slightly vary
depending on your OS.
There are two types of drivers for scanner, The
FUJITSU TWAIN 32 Scanner Driver and FUJITSU
ISIS Scanner Driver, as well as two software applica-
tions, ScandAll 21 and QuickScan Pro™, are provided
with this product. The following sections describe how
to install each driver and application.
1. Turn on your PC and log on to Windows.
When using Windows 2000 or Win-
ATTENTION
dows XP, log on as a user with
"Administrator" privileges.
Please install the scanner driver
ATTENTION
before connecting the scanner to your
PC.
2. Insert the Setup CD-ROM into the CD drive.
If you connect the scanner before
installing the scanner driver, the scan-
ner will not operate correctly.
If you have connected the scanner
beforehand, the "Found New Hard-
ware Wizard" screen appears (this
screen might differ slightly according
to the used OS) . On this screen, click
the [Cancel] button to close the
Wizard screen and install the scanner
driver first.
⇒ <SETUP DISK START UP SCREEN> appears.
This screen may not appear when the
ATTENTION
"Autoplay" setting of your PC is OFF.
In this case, run "Install.exe" in this
CD-ROM directly from the "Explorer"
or "My Computer".
3. Click [INSTALL PRODUCTS].
For FUJITSU TWAIN32 Scanner Driver
■ Preparation
Confirm the following items before installing the appli-
cation.
• Remove the Setup CD-ROM from its package.
• Uninstall any older version of FUJITSU
TWAIN 32 driver if already installed.
Uninstall [Scanner Utility for Microsoft
ATTENTION
Windows] from [Add/Remove Pro-
grams] of the control panel.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Click [TWAIN Driver] on the window below.
8. When the [InstallShield Wizard Complete] win-
dow appears, click [Finish].
5. Error Recovery Guide Installation window
appears.
9. Your computer will be restarted.
Do not remove the Setup CD-ROM from the CD
drive until your PC has completely restarted.
Error Recovery Guide is a software that displays
troubleshooting information on screen when any
scanner error occurs. Although this software’s
installation is highly recommended, the perfor-
mance of the scanner would not be affected if
not installed.
Installation of the scanner driver is completed.
■ Installing ScandAll 21
"Scandall 21" is an image capturing software that com-
plies with the TWAIN standard. The FUJITSU TWAIN
32 scanner driver enables you to capture images with a
FUJITSU image scanner fi-series product.
When you select [Yes] for installing
ATTENTION
the Error Recovery Guide, [Choose
Setup Language] window appears.
Select a language and follow the
instructions on the window. Error
Recovery Guide will automatically
continue finishing its installation.
Please wait until the installation of
TWAIN driver automatically starts.
When using Windows 2000 or Win-
ATTENTION
dows XP, log on as a user with
"Administrator" privileges.
1. Insert the Setup CD-ROM into the CD drive.
6. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
⇒ <SETUP DISK START UP SCREEN> appears.
2. Click [INSTALL PRODUCTS].
7. Follow the instructions on the window to install
the application.
fi-5110C Image Scanner Getting Started
4
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Click [ScandAll 21] on the window below.
For FUJITSU ISIS Scanner Driver
■ Preparation
Remove the Setup CD-ROM from its package.
■ Installing the FUJITSU ISIS
Scanner Driver
Windows XP screenshots are used in
ATTENTION
4. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
this section as examples. The win-
dows and operations may vary slightly
depending on your OS.
1. Turn your PC on and log on to Windows.
When using Windows 2000 or Win-
ATTENTION
dows XP, log on as a user with
"Administrator" privileges.
5. Install the application following the instructions
on the window.
2. Insert the "Setup CD-ROM" into the CD drive.
6. When the [InstallShield Wizard Complete] win-
dow appears, click [Finish].
⇒ <SETUP DISK START UP SCREEN> appears.
This screen may not appear when the
ATTENTION
"Autoplay" setting of your PC is OFF.
In this case, run "Install.exe" in this
CD-ROM directly from the "Explorer"
or "My Computer".
3. Click [INSTALL PRODUCTS].
For finishing the installation, it may be
ATTENTION
necessary to restart your computer.
Follow the instructions on the window.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Click [ISIS Driver] on the window below.
■ Installing QuickScan Pro™
"QuickScan Pro™" is an image capturing software that
complies with the ISIS standard. The FUJITSU ISIS
scanner driver enables you to capture images with a
FUJITSU image scanner fi-series product
• When using Windows 2000 or Win-
ATTENTION
dows XP, log on as a user with
"Administrator" privileges.
• If an older version of QuickScan has
already been installed on your PC,
uninstall it before installing this ver-
sion.
5. Error Recovery Guide Installation window
appears.
1. Insert the Setup CD-ROM into a CD drive.
Error Recovery Guide is a software that displays
troubleshooting information on screen if any
scanner error occurs. Although this software’s
installation is highly recommended, the perfor-
mance of the scanner would not be affected if
not installed.
⇒ <SETUP DISK STARTUP SCREEN> appears.
2. Click [INSTALL PRODUCTS].
When you select [Yes] for installing
ATTENTION
Error Recovery Guide, the [Choose
Setup Language] window appears.
Select a language and follow the
instructions on the window. The Error
Recovery Guide will automatically
continue finishing its installation.
Please wait until the installation of
ISIS driver automatically starts.
6. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
3. Click [QuickScan PRO (Trial)] on the window
below.
7. Follow the instructions on the window to install
the application.
8. When the [InstallShield Wizard Complete]
window appears, click [Finish].
4. Continue to install the application following the
instructions on the window.
9. Your computer will be restarted. Do not remove
the Setup CD-ROM from the CD drive until your
PC has completely restarted.
Now the installation of the scanner driver is completed.
fi-5110C Image Scanner Getting Started
6
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Insert the Setup CD-ROM in your CD drive.
The <SETUP DISK STARTUP SCREEN> will
appear.
2. Click [Install Products].
5. Enter the required information, then click
[Next >] button.
3. Click [Error Recovery Guide] on the next screen.
"QuickScan Pro™" included in the
ATTENTION
Setup CD-ROM is an evaluation ver-
sion. For further use after the expira-
tion of its evaluation period of up to 30
launches, it is necessary to purchase
a fully functional version of QuickScan
Pro™. (When you install the evalua-
tion version, do not change the Serial
Number already displayed.)
4. Select a language to use for the installation in
the <Choose Setup Language> window and
click [OK].
6. Install the application following the instructions
on the window.
5. Install the application following the instructions
in the window.
Error Recovery Guide
If you did not install together the Error Recovery Guide
with the driver, please proceed with the procedures
given below for installing it.
Error Recovery Guide is a software that displays trou-
bleshooting information on screen if any scanner error
occurs.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
6. When the [InstallShield Wizard Complete]
screen displays, click [Finish].
This window is not displayed aou-
tomatically when the "Auto play" set-
ting of your computer is deactivated.
In this case, please run "Auto
ATTENTION
play.exe" of this CD-ROM directly
using the "Explore" or "My computer".
2. Select the language and Click [OK] button.
Image Processing Software Option
(Trial)
To install the image processing software option (trial
version) , please refer to the "Image Processing Software
Option User's Guide".
3. Select "Install Adobe Acrobat 7.0 Standard".
®
®
Adobe Acrobat
Install Adobe Acrobat from the "Adobe Acrobat 7.0
CD-ROM" provided with this scanner.
Adobe Acrobat 7.0 Standard is not
ATTENTION
supported by Microsoft Windows 95,
Microsoft Windows 98/98SE,
Microsoft Windows NT4.0, Microsoft
Windows Me.
4. Click the [Next] button. The set up window
appears.
Adobe Acrobat is required for display-
HINT
ing the manuals stored in the CD-
ROM.
* Installation of Adobe Acrobat 7.0 is
not necessary if it has already been
installed in your PC.
1. Insert the "Adobe Acrobat 7.0 CD-ROM" into the
CD-ROM drive.
⇒ The "Adobe Acrobat 7.0 Standard - Setup" win-
dow appears.
fi-5110C Image Scanner Getting Started
8
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Follow the instructions to install the software.
Select "How to install" on the "Adobe
Support and User registration for
Adobe products:
ATTENTION
Refer to the technical support informa-
tion stored in the [Customer Support]
folder on Adobe Acrobat 7.0 Standard
CD-ROM. (Note that free person-to-
person support is not available for this
bundled product.)
HINT
Acrobat 7.0 Standard" window to learn
more about Adobe Acrobat 7.0 installa-
tion. Refer to "Adobe Acrobat Help"
about how to use Adobe Acrobat7.0.
Notes for using Adobe Acrobat 7.0
ATTENTION
When scanning a paper document
and converting the image to PDF
using Acrobat 7.0, unexpected images
may be output when:
2.2 Installing the Scanner
After the computer has been restarted, connect the scan-
ner.
1. Setting "Edge Shadow Removal" in
Acrobat, and setting "Digital
Endorser" or "Black Background"
options in the TWAIN driver at the
same time. Letter strings embed-
ded in the image or the background
may be missed.
1. Place the scanner at its installation site.
For details on the scanner's dimensions and required
installation space, refer to "fi-5110C Operator’s
Guide" "9.2 Installation Specifications" in the Setup
CD-ROM.
Solution 1: Set "Edge shadow
removal" to "OFF" or set any option
other than "Adaptive" for
"Color/Grayscale" and/or "Mono-
chrome" under "Compression" by
selecting [File]->[Create PDF]->
[From Scanner...]-> [Image Set-
tings...] in Acrobat.
2. Attach the ADF Paper Chute.
Hold the ADF paper chute and insert its tabs into the
corresponding slots in the scanner as shown in the
figure below.
The Side guides of the ADF paper chute have to face
up.
Solution 2: Adjust the scanning
density in the TWAIN driver.
ADF paper chute
2. Setting "Adaptive" for "Color/Gray-
scale" and/or "Monochrome" under
"Compression" in Acrobat and
scanning in a resolution lower than
the resolution recommended for
Acrobat.
Tab
Solution: Set OPTION to some-
thing other than "Adaptive" under
"Compression."
3. Scanning a document longer than
the double letter (11x17) or A3 size,
when setting "Overscan" in the
TWAIN driver, the scan may fail.
Solution: When scanning a double
letter (11x17) or A3 size of docu-
ment, do not set "Overscan" in
TWAIN driver.
Side guide
*As for detailed usage and information
of Acrobat, refer to "Create a PDF file
from a scanned document" in Acrobat
Help.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Connect the AC adapter.
2.3 Connecting the USB Cable
Follow the procedure below to connect the USB cable.
Use only the AC adapter provided by
the manufacturer.
ATTENTION
1. Connect the USB interface cable to the USB
interface connector.
1) Connect the AC cable to the AC adapter.
2) Connect the AC adapter connector to the
scanner’s DC inlet.
2. Connect the other end of the USB interface
cable to the PC.
• Be sure to use the USB cable which
ATTENTION
comes as an accessory with this
scanner.
Correct operation with commercially
available cables is not guaranteed.
• When connecting to an USB hub,
use the first stage USB hub that is
closest to the computer. If you use
the second or later hub stages, the
scanner may not operate correctly.
3) Plug the AC cable into the outlet.
3. Press the power button to turn ON the scanner.
Your scanner will be automatically detected.
The Function Number Display and the
LED may flash for an instant when
plugging the AC cable into the scanner.
HINT
For Windows 98:
When a request for inserting the CD-ROM for
Windows 98 appears, insert it into the CD drive and
click the [OK] button.
For Windows 2000:
When [Digital Signature not Found] appears, click
[Yes].
The installation of the scanner is completed.
fi-5110C Image Scanner Getting Started
10
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Set scanning resolution, document size, etc. on
the [TWAIN driver] window (for setting details of
scanning) and click the [Scan] button.
2.4 Confirming Installation
To confirm whether the installation was successful, per-
form a scanning operation with an application that com-
plies with either the TWAIN regulations, such as
ScandAll 21 or the ISIS regulations such as QuickScan
ProTM
.
■ Confirming with ScandAll 21
1. Load the documents on the scanner.
For details on loading documents, refer to "2.2 Load-
ing Documents on the ADF for Scanning" in the fi-
5110C Operator's Guide on the Setup CD-ROM.
2. Start ScandAll21.
Select [Start] - [Programs] - [Scanner Utility for
Microsoft Windows] - [ScandAll 21].
For details on [TWAIN driver], refer to
the "FUJITSU TWAIN32 Scanner
HINT
Driver User’s Guide" provided in the
Setup CD-ROM.
3. Specify the scanner (that you will use)
Select [Select Source...]from the [Scan] menu of
ScandAll 21.
7. Documents are scanned, and the scanned
images are displayed on the [ScandAll 21] win-
dow.
4. Select "FUJITSU fi-5110Cdj" on the dialog box.
If the scanning completes without any trouble, the
installation performed successfully.
5. Select [To View...] from the [Scan] menu.
For details on various types of scanning, refer to the
"fi-5110C Operator’s Guide" on the Setup CD-ROM.
■ Confirming with QuickScan Pro™
1. Load the documents on to the scanner.
For details on loading documents, refer to "2.2 Load-
ing Documents on the ADF for Scanning" in the fi-
5110C Operator's Guide on the Setup CD-ROM.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Start QuickScan Pro™.
Refer to "QuickScan Overview" or
"QuickScan Help" for information about
QuickScan Pro™ functions and opera-
tions. On the [Start] menu, point to
[Programs]-[QuickScan] and click the
file.
From the [Start] menu, select [Programs]-[Quick-
Scan]-[QuickScan].
HINT
3. Select [Select Scanner...] from [Scan] menu in
QuickScan Pro™.
And, select fi-5110C from the list of [Scanner:], and
then click the [OK] button.
4. Select [Preview Settings...] from the [Scan]
menu. Set the scan resolution, paper size and
other scanning requirements, and then click
[OK].
5. Select [Preview Scan] from the [Scan] menu.
And then the document is scanned.
If the scanning completes without any trouble, the
installation performed successfully.
fi-5110C Image Scanner Getting Started
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 1 TROUBLESHOOTING
■ Troubleshooting checklist
Symptom
Check this item
Remedy
Scanner does not turn
on.
Have you pressed the power
button on?
Push the power button in to turn the scan-
ner.
Are the AC cable and AC adapter
properly connected to the scan-
ner?
Correctly connect the AC cable and the AC
adapter.
Disconnect the AC cable and the AC
adapter from the scanner, then connect
them again.
If this does not restore the power supply,
contact the store where you purchased the
scanner or an authorized FUJITSU scanner
service provider.
Are you using the correct AC cable You must use the AC adapter and cable
and AC adapter supplied with the
scanner from the manufacture?
supplied with your scanner by the
manufacture. Please get the correct AC
adapter and cable to connect to your scan-
ner.
Scanning does not
commence.
Are the documents loaded properly Realign and reload the documents on to
on to the ADF paper chute?
ADF paper chute.
Is the ADF closed completely?
Close the ADF completely.
Is the USB cable cable connected Connect the cable. (When a USB hub is
securely? used, check the hub's power supply.)
Does the Function Number display When the Function Number display indi-
indicates an alarm or an error?
cates an alarm or an error, refer to "Chap-
ter 6 TROUBLESHOOTING" in the fi-
5110C Operator’s Guide for removing the
alarm or the error.
The alarm status remain displayed Turn off and on the power button.
even after the scanner has been
turned off and on again?
If this does not eliminate the alarm status,
contact the store where you purchased the
scanner or an authorized FUJITSU scanner
service provider.
Vertical lines appear in
the printed image.
Is the glass dirty?
Clean the glass as instructed in the Opera-
tor's Guide "4. Daily Care".
The scanned printed
Have the documents been loaded
Reload the documents correctly.
image appears shifted or correctly?
distorted.
Quality of the scanned
image is not satisfactory.
Is the glass clean?
Clean glass and otther dirty locations
around glass and ADF.
AP-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Check this item
Remedy
Paper frequently multi
feeds.
Have the document requirements
of the fi-5110C Operator’s Guide’s
"Document Quality" and the "multi
Use document conditions that meet the
"Document Quality" and the "Multi Feed
Detection Conditions" in chapter 7 of the fi-
feed Detection Conditions" of chap- 5110C Operator’s Guide.
ter 7 been satisfied?
Are the documents placed properly Fan the documents before scanning. Cor-
in the ADF paper chute?
rectly align the document stack and load
them on the ADF paper chute. Refer to "2.2
details.
Is the stack of document thicker
than 5 mm?
Reduce the number of sheets of the stack
to a thickness of 5 mm or less.
Is the Pad ASSY dirty?
Clean the Pad ASSY. Refer to Operator's
Guide in "Chapter 4 Daily Care".
Is the Pad ASSY worn out?
Replace the Pad ASSY. Refer to Opera-
tor's Guide in "5.2. Replacing the Pad
ASSY".
Paper does not feed
(pick error occurs fre-
quently, or document
stops midway).
Have the document requirements
of the fi-5110C Operator’s Guide’s
"Document Quality" and the "Multi
Feed Detection Conditions" of
Use document conditions that meet the
"Document Quality" and the "Multi Feed
Detection Conditions" in the chapter 7 of
the fi-5110C Operator’s Guide.
chapter 7 been satisfied?
Is the Pick roller dirty?
To clean the pick roller, refer to Operator's
Guide in "Chapter 4 Daily Care".
Is the Pick roller worn out?
Change the Pick roller. Refer to Operator's
Guide in "5.3. Replacing the Pick Roller".
Is there any dirt or dust in the docu- Remove any dirt or dust from the docu-
ment feed path?
ment feed path.
Are the scanned images Are the Feed rollers dirty?
elongated?
Clean the Feed rollers. Refer to Operator's
Guide in "Chapter 4 Daily Care".
Have you adjusted the scan scale? Select "Scanners and Cameras" in the con-
trol panel, then click the [Device Set] tab to
adjust scale.
Is there a shadow on the Are the Feed rollers dirty?
Clean the Feed rollers. Refer to Operator's
Guide in "Chapter 4 Daily Care".
top or bottom edge of
the scanned image?
Is the offset adjusted?
On [Scanners and Cameras] in the control
panel, adjust the [Sub-scan Setting] (in
case there is a shadow in the top edge) or
adjust the [Bottom] (in case there is a
shadow in the bottom edge).
fi-5110C Image Scanner Getting Started
AP-2
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Temporary error
■
Device alarm (Non-Temporary error)
Indication
Meaning
Paper feed error
Multi Feed error
Indication
Meaning
U1
U2
U4
E2
E3
E4
E6
E7
E9
Ec
Trouble in the optical system (front).
Trouble in the optical system (back).
The motor’s fuse has blown out.
Trouble with the operator panel.
Trouble occurred with the EEPROM.
An error in the image memory.
An alarm in the memory.
The ADF has been opened during
scanning.
To troubleshoot the indicated errors above:
• "U1" error
Remove all jammed documents.
Confirm that the documents meet the paper condi-
tions for scanning.
Refer to fi-5110C Operator’s Guide "7.2 Document
Quality" on the Setup CD-ROM.
When you encounter any alarm on the display, turn
the scanner off and on. If the alarm is still displayed
on the Function Number display, contact the store
where you purchased the scanner or an authorized
FUJITSU scanner service provider.
• "U2" error
Remove all jammed documents.
Confirm that the documents are within the required
paper preconditions for scanning.
Refer to fi-5110C Operator’s Guide "7.2 Document
Quality" on the Setup CD-ROM.
• "U4" error
Close the ADF cover completely. For the details,
refer to "6 TROUBLESHOOTING" in the "fi-
5110C Operator's Guide" on the Setup CD-ROM.
AP-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 2 DAILY CARE
■ Parts to Clean and When
When operating the scanner, the
ADF’s inside glass becomes
very hot.
Part to clean
Standard Cleaning Cycle
Before you clean inside the
scanner, turn off its power and
unplug the AC adapter from the
outlet. Wait for at least
15 minutes.
Pad ASSY
Pick roller
Feed rollers
Plastic rollers
Glass
Clean these parts after every
1,000 scans.
Do not turn off the scanner when
you clean the Feed rollers or
Eject rollers.
■ Cleaning Materials
The scanner must be cleaned
ATTENTION
frequently if you scan any of the
following type of paper sheets:
• Documents of coated paper
• Documents that are almost completely
covered with printed text or graphics
• Chemically treated documents such as
carbonless paper
Cleaning
Materials
Parts
Remarks
Number
Cleaner F1
(or isopropyl
alcohol)
CA99501- 1 bottle
0013 Moisten the cloth
with this fluid and
wipe the scanner
clean.(*)
• Documents containing a large amount
of calcium carbonate
• Handwritten documents
Lint-free dry
cloth
Commercially available one
* For details about cleaning materials, contact the
FUJITSU scanner dealer where you purchased the
scanner.
For details on the cleaning the ADF, refer to "Chapter 4
Daily Care" in fi-5110C Operator’s Guide in the Setup
CD-ROM".
■ Cleaning Method
The ADF must be cleaned with a lint-free cloth
moistened with the Cleaner F1.
Do not use aerosol sprays to clean
ATTENTION
the scanner. Aerosol sprays can blow
dirt and dust inside the scanner,
resulting in scanner failure or
malfunction.
fi-5110C Image Scanner Getting Started
AP-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 3 REPLACING CONSUMABLES
The illustration below demonstrates the locations of the
During its operation, the inside
glass of the ADF becomes very
hot .
replacement parts. Refer to "Chapter 5 Replacing
Consumables" fi-5110C Operator’s Guide on the Setup
CD-ROM.
Before replacing the
consumables, turn the scanner
off and unplug the AC adapter
from the outlet. Wait at least
15 minutes.
■ Replacing the Pad ASSY
■ Consumables and Replacement
Cycles
Below are specifications of consumable items and
their recommended replacement cycles.
■ Replacing the Pick Roller
Standard
Parts
Description
Pad ASSY
Pick roller
Replacement
Cycle
Number
PA03360-
0002
After 50,000 scans
or one year
PA03360-
0001
After 100,000
scans or one year
To purchase consumables, contact the store where you
purchased the scanner or an authorized FUJITSU scan-
ner service provider.
Pick Roller Bushing
Pick Roller Shaft
The replacement cycles above are rough guidelines
when using A4 or Letter woodfree or wood containing
paper 64 g/m2 (17 lb). This cycle varies according to the
type of paper and how frequently the scanner is used and
cleaned.
Use only the consumables specified
ATTENTION
by PFU Limited.
Pick Roller Shaft
Pick Roller
AP-5
Download from Www.Somanuals.com. All Manuals Search And Download.
fi-5110C Image Scanner Getting Started
P3PC-1072-03EN
Date of issuance: June, 2006
Issuance responsibility: PFU LIMITED
Printed in China
z Copying of the contents of this manual in whole or in part and
copying of the scanner application is forbidden under the copyright
law.
z The contents of this manual are subject to change without notice.
z PFU LIMITED. is not liable whatsoever for any damages resulting
from use of this scanner and procedures described in this manual,
profit due to defects, and any claims by a third party.